1
|
Gallitto E, Faggioli G, Lodato M, Caputo S, Cappiello A, Di Leo A, Pini R, Vacirca A, Acquisti E, Gargiulo M. T-branch by partial deployment technique in the endovascular repair of complex aortic and thoracoabdominal aneurysms with narrow or severe angulated para-visceral aorta. J Vasc Surg 2025; 81:1040-1048.e3. [PMID: 39800118 DOI: 10.1016/j.jvs.2025.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2024] [Revised: 01/02/2025] [Accepted: 01/04/2025] [Indexed: 01/15/2025]
Abstract
OBJECTIVE The partial deployment technique (PDT) is an unconventional option of T-branch deployment to allow target arteries (TAs) cannulation/stenting from the upper arm access, in case of narrow (NPA <25 mm) or severely angulated (APA >60°) aorta. Aim of this study was to report outcomes of the endovascular repair of complex aortic (c-AAAs) and thoracoabdominal (TAAAs) aneurysms by T-branch and PDT. METHODS All consecutive patients underwent urgent endovascular repair of c-AAAs and TAAAs by T-branch (Cook Medical) and PDT from 2021 to 2023 were analyzed. Technical success (TS), 30-day mortality, and TA instability within 30 days and 1 year, as well as reinterventions, were assessed as primary endpoints. Time of intraoperative pelvic/lower limb ischemia, spinal cord ischemia (SCI), and perioperative stroke were assessed as secondary endpoints. RESULTS Thirty-three cases were analyzed. There were six type I endoleaks (18%) in failed endovascular aortic repair, nine juxta/para-renal aneurysms (28%), six post-dissection TAAAs (18%), and 12 degenerative TAAAs (36%), respectively. The median para-visceral aortic lumen diameter was 23 mm (interquartile range [IQR], 19-27 mm), and 10 cases (30%) had APA. Of 128 TAs, 111 (87%) were cannulated/stented with distally captured aortic graft. The median time of pelvic/lower limb ischemia was 120 minutes (IQR, 90-150 minutes). TS was achieved in all patients. One patient (3%) suffered SCI, and there were no cases of stroke. An asymptomatic renal artery occlusion was detected at postoperative imaging, which was recanalized by thrombus-aspiration/relining. This was the only case of TA instability (1/128; 0.8%) and reintervention (1/33; 3%) within 30 days. Two patients (6%) died within 30 days. Median follow-up was 14 months (IQR, 6-22 months). One case (3%) of bilateral renal artery occlusion occurred at 6 months. No superior mesenteric artery or celiac trunk events occurred, with an overall TA instability rate of 2% (3/128). Eighteen patients (55%) completed the radiologic follow-up at 1 year with no new cases of TA instability. Freedom from TA instability was 91% at 1 year. CONCLUSIONS T-branch by PDT seems to be safe and effective in the management of c-AAAs/TAAAs with NPA or APA. Results were satisfactory in terms of TS and mid-term TA instability, suggesting a possible enlargement of the anatomical feasibility criteria for outer branches in urgent cases.
Collapse
Affiliation(s)
- Enrico Gallitto
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy; Vascular Surgery, IRCCS Sant'Orsola, Bologna, Italy.
| | - Gianluca Faggioli
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy; Vascular Surgery, IRCCS Sant'Orsola, Bologna, Italy
| | - Marcello Lodato
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy
| | - Stefania Caputo
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy
| | | | - Antonino Di Leo
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy
| | - Rodolfo Pini
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy; Vascular Surgery, IRCCS Sant'Orsola, Bologna, Italy
| | - Andrea Vacirca
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy; Vascular Surgery, IRCCS Sant'Orsola, Bologna, Italy
| | | | - Mauro Gargiulo
- Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy; Vascular Surgery, IRCCS Sant'Orsola, Bologna, Italy
| |
Collapse
|
2
|
Nana P, Dakis K, Brodis A, Torrealba JI, Panuccio G, Spanos K, Kölbel T. Systematic Review and Meta-analysis of Outcomes of the Advanta V12 or iCAST Bridging Stent Graft Used for Fenestrated and Branched Endovascular Aortic Repair. Eur J Vasc Endovasc Surg 2025; 69:547-559. [PMID: 39814313 DOI: 10.1016/j.ejvs.2025.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 11/30/2024] [Accepted: 01/06/2025] [Indexed: 01/18/2025]
Abstract
OBJECTIVE Half of re-interventions after fenestrated and branched endovascular aortic repair (FB-EVAR) are target vessel related. Regarding bridging stent choice, existing data are controversial. This meta-analysis aimed to evaluate the performance of Advanta V12/iCAST as the bridging stent in FB-EVAR. DATA SOURCES The English medical literature was searched through MEDLINE, Embase (via Ovid), and Cochrane databases (end date 15 April 2024). REVIEW METHODS The Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and PICO (Patient, Intervention, Comparison, Outcome) model were followed. A predefined protocol was registered to PROSPERO (CRD42024556603). Randomised controlled trials and observational studies (2010 - 2024) reporting on Advanta V12/iCAST related target vessel outcomes were eligible. Risk of bias was assessed using ROBINS-I, and evidence quality was assessed via Grading of Recommendations Assessment, Development and Evaluations (GRADE). Primary outcomes were freedom from instability, stenosis and or occlusion, types Ic and IIIc endoleak, and re-intervention of target vessels bridged with the Advanta V12/iCAST. Prevalence and regression meta-analysis were performed. RESULTS From 1 439 articles, ten retrospective studies (7 525 target vessels; 3 890 target vessels bridged with Advanta V12/iCAST) were included. According to ROBINS-I, no study was of high quality. Mean follow up was 24.3 (95% confidence interval [CI] 23.9 - 24.7) months. Freedom from instability, stenosis and or occlusion, and types Ic and IIIc endoleak were 94% (95% CI 91 - 96%; p < .010; I2 = 91%; GRADE certainty, very low), 97% (95% CI 96 - 98%; p = .070, I2 = 44%; GRADE certainty, low), and 97% (95% CI 94 - 98%; p < .010; I2 = 81%; GRADE certainty, very low), respectively. Freedom from target vessel re-intervention was 95% (95% CI 92 - 97%; p < .010; I2 = 85%; GRADE certainty, very low). Four studies provided extractable data on Advanta V12/iCAST in fenestrations and four in branches. No difference was detected in freedom from instability (p = .47), stenosis and or occlusion (p = .36), and types Ic and IIIc endoleak (p = .90). Freedom from re-intervention was 93% (95% CI 87 - 96%; p < .010; I2 = 90%) in fenestrations and 95% (95% CI 91 - 97%; p = .060, I2 = 64%) in branches. CONCLUSION The Advanta V12/iCAST bridging stent showed high freedom from target vessel instability, stenosis and or occlusion, and endoleak. Freedom from re-intervention was 95%, being similarly high in fenestrations and branches.
Collapse
Affiliation(s)
- Petroula Nana
- German Aortic Centre, Department of Vascular Medicine, University Heart and Vascular Centre UKE Hamburg, Hamburg, Germany.
| | - Konstantinos Dakis
- Department of Vascular Surgery, Larissa University Hospital, Faculty of Medicine, University of Thessaly, Larissa, Greece
| | - Alexandros Brodis
- Department of Neurosurgery, Larissa University Hospital, Faculty of Medicine, University of Thessaly, Larissa, Greece
| | - José I Torrealba
- German Aortic Centre, Department of Vascular Medicine, University Heart and Vascular Centre UKE Hamburg, Hamburg, Germany
| | - Giuseppe Panuccio
- German Aortic Centre, Department of Vascular Medicine, University Heart and Vascular Centre UKE Hamburg, Hamburg, Germany
| | - Konstantinos Spanos
- German Aortic Centre, Department of Vascular Medicine, University Heart and Vascular Centre UKE Hamburg, Hamburg, Germany; Department of Vascular Surgery, Larissa University Hospital, Faculty of Medicine, University of Thessaly, Larissa, Greece
| | - Tilo Kölbel
- German Aortic Centre, Department of Vascular Medicine, University Heart and Vascular Centre UKE Hamburg, Hamburg, Germany
| |
Collapse
|
3
|
Karelis A, Kölbel T, Mastracci T, Katsargyris A, Haulon S, Tsilimparis N, Antoniou GA. Branched Endovascular Aneurysm Repair with Inner and Outer Branches: A Systematic Review and Meta-analysis. Eur J Vasc Endovasc Surg 2025:S1078-5884(25)00231-X. [PMID: 40064233 DOI: 10.1016/j.ejvs.2025.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2024] [Revised: 02/18/2025] [Accepted: 03/05/2025] [Indexed: 05/09/2025]
Abstract
OBJECTIVE This systematic review aimed to assess the clinical outcomes of branched endovascular aneurysm repair (BEVAR) with inner branches (iBEVAR) and inner/outer branches (oBEVAR). DATA SOURCES A systematic literature review was performed using the electronic bibliographic databases MEDLINE, Embase, Scopus, Web of Science, and the Cochrane Library up to May 2024. REVIEW METHODS The review was designed and reported in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. Eligible studies reported death, technical failure, primary target vessel (TV) patency, TV related complications, branch related re-interventions, and spinal cord ischaemia (SCI). Risk of bias was evaluated with the ROBINS-I tool. RESULTS Twenty seven observational studies reporting a total of 1 780 patients treated with BEVAR and 6 633 TVs were included. Three hundred and eightysix patients (84.3%) were treated electively with iBEVAR and 72 (15.6%) urgently vs. 845 (63.2%) and 491 (36.7%) with oBEVAR, respectively. The pooled estimate of 30 day death was 4.9% (95% confidence interval [CI] 2.9 - 8.2%) for iBEVAR and 7.6% (95% CI 4.9 - 11.7%) for oBEVAR. Overall mortality rates were 13.8% (95% CI 9.7 - 19.1%) for iBEVAR vs. 15.4% (95% CI 10.6 - 21.9%) for oBEVAR. The rate of SCI was 6.5% (95% CI 4.2 - 10.0%) in iBEVAR compared with 12.9% (95% CI 9.6 - 17.1%) in oBEVAR. Primary TV patency was similar between iBEVAR (97.3%, 95% CI 94.8 - 98.6%) and oBEVAR (97.6%, 95% CI 95.3 - 98.7%). TV related complication rates were 2.9% (95% CI 2.0 - 4.1%) for iBEVAR vs. 3.9% (95% CI 2.7 - 5.6%) for oBEVAR. Technical failure rates were 4.1% (95% CI 2.4 - 6.9%) for iBEVAR vs. 5.7% (95% CI 3.5 - 9.1%) for oBEVAR. Grading of Recommendations Assessment, Development, and Evaluation (GRADE) certainty was low or very low for all outcomes. CONCLUSION BEVAR with inner and inner/outer branches has been used in elective and urgent cases, as well as across a variety of anatomies, with both designs demonstrating satisfactory clinical outcomes.
Collapse
Affiliation(s)
- Angelos Karelis
- Vascular Centre, Department of Thoracic Surgery and Vascular Diseases, Skåne University Hospital, Malmö, Sweden; Department of Clinical Sciences Malmö, Lund University, Malmö, Sweden.
| | - Tilo Kölbel
- German Aortic Centre, University Heart and Vascular Centre, University Medical Centre Eppendorf, Hamburg, Germany
| | - Tara Mastracci
- University College London, St Bartholomew's Hospital, London, UK
| | - Athanasios Katsargyris
- Department of Vascular and Endovascular Surgery, Paracelsus Medical University Nuremberg, General Hospital Nuremberg, Nuremberg, Germany
| | | | - Nikolaos Tsilimparis
- Department of Vascular Surgery, University Hospital, LMU Munich, Munich, Germany
| | - George A Antoniou
- Department of Vascular and Endovascular Surgery, Manchester University NHS Foundation Trust, Manchester, UK; Division of Cardiovascular Sciences, School of Medical Sciences, Manchester Academic Health Science Centre, The University of Manchester, Manchester, UK
| |
Collapse
|
4
|
Karaolanis GI, Makaloski V, Jungi S, Weiss S, Kotopoulos K, Chaikhouni B, Becker D, Kotelis D, Bosiers MJ. Endovascular repair of pararenal and thoracoabdominal aortic aneurysms with inner and outer off-the-shelf multibranched endografts: A systematic review and meta-analysis. J Vasc Surg 2025; 81:251-260.e3. [PMID: 39147287 DOI: 10.1016/j.jvs.2024.08.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 08/03/2024] [Accepted: 08/08/2024] [Indexed: 08/17/2024]
Abstract
BACKGROUND During the last years a great progress has been noted in device technology and operator experience in treating complex aortic aneurysms. Fenestrated and branched custom-made devices require detailed preoperative planning and production time that can take ≤12 weeks. During this awaiting period, aortic-related mortality is increased. To overcome this limitation, off-the-shelf standardized multibranched devices were launched in the market for the treatment of pararenal and thoracoabdominal aortic aneurysms (TAAAs). Our aim was to evaluate systematically all the published studies of off-the-shelf endografts for the treatment of pararenal and TAAAs. METHODS We performed a systematic review to identify all the eligible studies that reported outcomes to the off-the-shelf with inner or outer multibranched devices and then conducted a qualitative synthesis and meta-analysis of the results. The main outcomes were technical success, mortality, target visceral vessel instability, major adverse events, and reintervention rates. We estimated pooled proportions and 95% confidence intervals (CIs). RESULTS A total of 1605 study titles were identified by the initial search strategy, of which 13 (8 t-Branch, 3 E-nside, 1 We-Flow, and 1 TAMBE) were considered eligible for inclusion in the meta-analysis. A total of 595 patients (70% male) were identified among the eligible studies. In terms of procedures, 64.4% were elective, 19.2% (13.4% outer multibranched group [OMG]; 6.1% inner multibranched group [IMG]) were emergent, and 16.4% (15.6% OMG; 0.8% IMG) were urgent. The pooled technical success was 92.1% (95% CI, 83.8%-96.4%) and 96.9% (95% CI, 92.5%-98.8%) for the outer and inner multibranched endografts, respectively. The pooled 30-day mortality was 10.4 % (95% CI, 6.6%-16.1%,) and 4.2% (95% CI, 2.0%-8.6%) for the OMG and IMG, respectively. The pooled 30-day and late target visceral vessel instability for the OMG was 3.5% (95% CI, 2.0%-6.1%) and 6.2% (95% CI, 4.7%-8.0%) and for the IMG 10.4% (95% CI, 4.5%-22.5%) and 1.6% (95% CI, 0.7%-3.3%) respectively. CONCLUSIONS This pooled analysis indicated good technical success and mortality rates for both devices despite the high rate of urgent procedures. Pararenal and TAAAs can be treated safely using the included devices. However, further studies are required to draw additional conclusions for the IMG owing to the small sample size.
Collapse
Affiliation(s)
- Georgios I Karaolanis
- Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, Bern, Switzerland; Vascular Unit, Department of Surgery, University Hospital of Ioannina and School of Medicine, Ioannina, Greece.
| | - Vladimir Makaloski
- Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, Bern, Switzerland
| | - Silvan Jungi
- Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, Bern, Switzerland
| | - Salome Weiss
- Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, Bern, Switzerland
| | - Konstantinos Kotopoulos
- Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, Bern, Switzerland
| | - Basel Chaikhouni
- Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, Bern, Switzerland
| | - Daniel Becker
- Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, Bern, Switzerland
| | - Drosos Kotelis
- Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, Bern, Switzerland
| | - Michel J Bosiers
- Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, Bern, Switzerland
| |
Collapse
|
5
|
Płoński A, Płoński AF, Chlabicz M, Głowiński J. Endovascular Repair of Spontaneous Rupture of Stent Graft Branch in Thoracoabdominal Aortic Aneurysm-Management, Case Study, and Review. J Clin Med 2024; 13:7687. [PMID: 39768610 PMCID: PMC11676123 DOI: 10.3390/jcm13247687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2024] [Revised: 11/30/2024] [Accepted: 12/14/2024] [Indexed: 01/11/2025] Open
Abstract
Background: Stent-graft implantation is a widely recognized method for endovascular treatment of aortic aneurysms. In cases where the aneurysm involves the thoracic and abdominal aorta, repair including fenestrated and branched stent grafts provides a viable alternative. This approach, initially reserved for patients unsuitable for open surgery, has become preferred for anatomically appropriate thoracoabdominal aortic aneurysms. The Zenith t-Branch system has been extensively studied, demonstrating high technical success rates and acceptable mortality and morbidity. However, complications such as endoleaks, kinking, and stent-graft branch rupture remain significant challenges. Methods: We present the case of an 82-year-old male with a thoracoabdominal aortic aneurysm treated with endovascular aneurysm repair using the Zenith t-Branch. Four years post-implantation, he developed a spontaneous rupture of the stent-graft branch, leading to dangerous leakage and aneurysm sac enlargement. An urgent surgical intervention was performed, implanting additional Be-Graft into the damaged branch, restoring stent-graft continuity and revascularizing the superior mesenteric artery. Results: The procedure was completed successfully. We conducted a review of the latest literature on endovascular treatment of thoracoabdominal aortic aneurysms with particular emphasis on the possibility of repairing postoperative complications, especially endoleaks. Conclusions: While modern technologies have significantly improved outcomes, serious complications persist. Studies emphasize the importance of regular imaging follow-up for early complication detection and management. Continuous advancements in stent-graft technology aim to reduce complications further and improve outcomes. This case underscores the necessity of experienced operators in managing complex and rare complications and highlights the promising future of endovascular techniques in treating thoracoabdominal aortic aneurysms.
Collapse
|
6
|
Ferrer C, Gallitto E, Borghese O, Lodato M, Cappiello A, Cao P, Gargiulo M, Giudice R. Long-term results of fenestrated and branched endovascular aneurysm repair for complex abdominal and thoracoabdominal aortic aneurysms in young and fit patients. J Vasc Surg 2024; 80:1639-1649. [PMID: 39084495 DOI: 10.1016/j.jvs.2024.07.090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Revised: 07/19/2024] [Accepted: 07/23/2024] [Indexed: 08/02/2024]
Abstract
BACKGROUND Endovascular repair of complex abdominal aortic aneurysms (CAAAa) and thoracoabdominal aortic aneurysms (TAAAs) with fenestrated and branched devices (F/BEVAR) represents the first-line treatment in old or unfit patients. Currently, the widespread diffusion of these techniques has led to a progressive increase of complex endovascular procedures also in younger and fitter patients, but the related results have been only minimally reported, without long-term data. We investigated the long-term results of F/BEVAR for CAAA and TAAA repair in young and fit patients. METHODS All consecutive patients, aged ≤70 years, who underwent F/BEVAR for CAAA and TAAA over the last 13 years at two tertiary institutions were included in the study. All subjects presented a low to intermediate risk according to the Society for Vascular Surgery clinical comorbidity grading system. The primary end points were technical and clinical success and late overall and aortic-related survival. Major complications and specific target vessel-related outcomes were investigated as secondary end points. RESULTS A total of 183 patients (155 males [84.7%]; mean age, 64.5 ± 5.7 years; range, 33-70 years) underwent F/BEVAR during the study period, for a total of 167 degenerative (91.3%) and 16 postdissection (8.7%) aneurysms, including 44 (24%) juxtarenal, 33 (18%) pararenal, and 106 (58%) TAAAs. Technical and clinical success were achieved in 176 patients (96.2%) and 171 patients (93.4%), respectively. Four patients (2.2%) died perioperatively, of which two (1.1%) operated in emergency. Postoperatively, five patients (2.7%) presented permanent grade 3 spinal cord injury and three (1.6%) renal failure needing permanent dialysis. The mean follow-up was 65.7 ± 39.6 months (range, 1-158 months). The estimated overall and aortic-related survival at 12, 60, and 120 months was 94.0%, 85.1%, 72.2%, and 97.8%, 97.8%, 96.2%, respectively, and reintervention and branch instability-free survival at the same time points were 84.4%, 71.8%, 71.8%, and 93.2%, 86.3%, 72.2%, respectively. An aneurysm growth of >5 mm was detected in six patients (3.3%), and a sac shrinkage of >5 mm was achieved in 118 cases (64.5%). The Cox regression analysis demonstrated the need for unplanned procedure as the only risk factor for overall mortality (odds ratio, 3.331; 95% confidence interval, 1.397-7.940; P < .01]. CONCLUSIONS F/BEVAR in young and fit patients led to low perioperative mortality and major morbidity rates and a favorable overall survival rate in the long-term, making this technique particularly appealing in such a subgroup of patients. The availability of long-term data derived from the results of young patients, may additionally provide helpful information to redefine the indications for treatment and allow future targeted device and technique improvements.
Collapse
Affiliation(s)
- Ciro Ferrer
- Vascular Surgery Unit, San Giovanni-Addolorata Hospital, Rome, Italy.
| | - Enrico Gallitto
- Vascular Surgery Unit, University of Bologna and IRCCS Sant'Orsola, Bologna, Italy
| | - Ottavia Borghese
- Vascular Surgery Unit, San Giovanni-Addolorata Hospital, Rome, Italy
| | - Marcello Lodato
- Vascular Surgery Unit, University of Bologna and IRCCS Sant'Orsola, Bologna, Italy
| | - Antonio Cappiello
- Vascular Surgery Unit, University of Bologna and IRCCS Sant'Orsola, Bologna, Italy
| | | | - Mauro Gargiulo
- Vascular Surgery Unit, University of Bologna and IRCCS Sant'Orsola, Bologna, Italy
| | - Rocco Giudice
- Vascular Surgery Unit, San Giovanni-Addolorata Hospital, Rome, Italy
| |
Collapse
|
7
|
Spath P, Campana F, Gallitto E, Mascoli C, Caputo S, Pini R, Faggioli G, Gargiulo M. Primary Intra-operative Embolisation During Urgent Parallel Graft Endovascular Repair in Paravisceral Symptomatic Aortic Pseudoaneurysm. EJVES Vasc Forum 2024; 63:1-10. [PMID: 39803301 PMCID: PMC11718287 DOI: 10.1016/j.ejvsvf.2024.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2024] [Revised: 10/22/2024] [Accepted: 11/06/2024] [Indexed: 01/16/2025] Open
Abstract
Objective Paravisceral aortic lesions present significant challenges for endovascular treatment. This retrospective analysis of consecutively treated patients from April 2017 to June 2021 aimed to analyse the outcome of primary intra-operative embolisation of aortic complicated pseudoaneurysms and gutter channels during parallel graft (PG) repair of paravisceral symptomatic aortic pseudoaneurysms. Methods Patients with symptomatic pseudoaneurysms of the paravisceral aorta treated with PGs using chimney or periscope configurations were included. Thoracic endografts were positioned to exclude the aortic lesions. Coil embolisation of both the lesions and gutter channels was performed after graft deployment and prior to ballooning of the stent grafts. The primary endpoints were technical success (defined as exclusion of the pseudoaneurysm, target visceral vessel [TVV] patency, absence of gutter endoleaks) and clinical success (technical success + resolution of symptoms + absence of major adverse events) at 30 days. Secondary endpoints included overall survival, TVV patency, gutter endoleaks, and freedom from re-interventions during follow up. Results Six patients (four women) were treated for pseudoaneurysm rupture (three cases) and symptomatic aortic pseudoaneurysm (three cases) of the paravisceral aorta. The patients' anatomies were unsuitable for off the shelf devices and patients were all deemed to be at prohibitive surgical risk. A total of 15 TVVs were revascularised (comprising three coeliac arteries, five superior mesenteric arteries, and seven renal arteries) using 10 chimney and five periscope PGs. One coeliac artery was occluded. Seventy coils were deployed to embolise both the aortic ruptures and gutter channels. Both technical and clinical success rates were 100%. The median follow up was 17 months (IQR 5, 35), during which time three patients died due to non-aortic related causes. One coeliac artery (6%) was occluded, and no endoleak evidence was found. Conclusion Primary intra-operative embolisation during parallel graft endovascular repair of paravisceral symptomatic aortic pseudoaneurysms may be both safe and effective in excluding the pseudoaneurysm when other options are unavailable.
Collapse
Affiliation(s)
- Paolo Spath
- Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
- Vascular Surgery Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Italy
- Vascular Surgery Unit, Hospital «Infermi», AUSL Romagna, Rimini, Italy
| | - Federica Campana
- Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Enrico Gallitto
- Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
- Vascular Surgery Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Italy
| | - Chiara Mascoli
- Vascular Surgery Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Italy
| | - Stefania Caputo
- Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
| | - Rodolfo Pini
- Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
- Vascular Surgery Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Italy
| | - Gianluca Faggioli
- Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
- Vascular Surgery Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Italy
| | - Mauro Gargiulo
- Vascular Surgery, Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna, Italy
- Vascular Surgery Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Italy
| |
Collapse
|
8
|
Gallitto E, Faggioli G, Austermann M, Kölbel T, Tsilimparis N, Dias N, Melissano G, Simonte G, Katsargyris A, Oikonomou K, Mani K, Pedro LM, Cecere F, Haulon S, Gargiulo M. Urgent endovascular repair of juxtarenal/pararenal aneurysm by off-the-shelf multibranched endograft. J Vasc Surg 2024; 80:1336-1349.e4. [PMID: 38992807 DOI: 10.1016/j.jvs.2024.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Revised: 07/01/2024] [Accepted: 07/03/2024] [Indexed: 07/13/2024]
Abstract
OBJECTIVE To report outcomes of urgent juxtarenal/pararenal aneurysms (J/P-AAAs) managed by off-the-shelf multibranched thoracoabdominal endografts (Cook, T-branch). METHODS In this observational, multicenter, retrospective study, patients with J/P-AAAs treated by urgent endovascular repair by T-branch in 23 European aortic centers, from 2013 to 2023, were analyzed. Contained J/P-AAAs rupture, presence of related symptoms, and aneurysm diameter of >70 mm were considered as indication for urgent repair. Technical success (TS), spinal cord ischemia (SCI), and 30-day/hospital mortality were assessed as early outcomes. Survival, freedom from reinterventions, and target artery instability (TAI) were evaluated during follow-up. RESULTS Overall, 197 patients (J-AAAs, n = 64 [33%]; P-AAAs, n = 95 [48%]; previous failed endovascular aneurysm repair (EVAR), n = 38 [19%]) were analyzed. The mean age and aneurysm diameter was 75 ± 8 years and 76 ± 4 mm, respectively. The American Society of Anesthesiologists score was 3 and 4 in 118 (60%) and 79 (40%) patients. Rupture, symptoms, and diameter of >70 mm were present in 51 (26%), 110 (56%), and 53 (27%) patients, respectively. An adjunctive proximal thoracic endograft was used in 28 cases (14%). The mean aortic coverage between the upper portion of the endograft and the lowest renal artery was 154 ± 49 mm. Single-stage repair and cerebrospinal fluid drainage were reported in 144 (73%) and 53 (27%) cases, respectively. TS was achieved in 182 (92%) cases (rupture, 84% vs no rupture, 95%; P = .02). Failures consist of TA loss (11 [6%]: renal artery, 9; celiac trunk, 2), type I to III endoleaks (2 [1%]), and 24-h mortality (2 [1%]). Rupture was a risk factor for technical failure (P = .02; odds ratio [OR], 3.8; 95% confidence interval [CI], 1.1-12.1). Overall, 15 patients (8%) had persistent SCI (rupture, 14% vs no rupture, 5%) with 11 (6%) , of paraplegia (rupture, 10% vs no rupture, 5%; P = .001). Rupture (P = .04; OR, 3.1; 95% CI, 1.1-8.9) and adjunctive proximal thoracic endograft (P = .01; OR, 4.1; 95% CI, 1.3-12.9) were risk-factors for SCI. Twenty-two patients (11%) died within 30 days or during a prolonged hospitalization. Previous failed EVAR (P = .04; OR, 3.6; 95% CI, 1.1-12.3), paraplegia (P < .001; OR, 9.9; 95% CI, 1.6-62.2) and postoperative mesenteric complications (P = .03; OR, 10.4; 95% CI, 1.2-93.3), as well as cardiac (P = .03; OR, 8.2; 95% CI, 2.0-33.0) and respiratory (P < .001; OR, 10.1; 95% CI, 2.9-35.2) morbidities were associated with 30-day/hospital mortality. The mean follow-up was 19 ± 5 months. The estimated 3-year survival and freedom from reinterventions was 58% and 77%, respectively. TAI occurred in 27 patients (14%) (occlusion, 15; endoleak, 14) with an estimated 3-year freedom from TAI of 72%. CONCLUSIONS Urgent repair of J/P-AAAs by T-branch is feasible and effective with satisfactory TS and 30-day/hospital mortality in high-risk patients. However, extensive aortic coverage is necessary, leading to a non-negligible SCI rate, especially in case of aortic rupture or when adjunctive thoracic endografts are necessary. Previous failed EVAR and postoperative mesenteric complications, as well as cardiac and respiratory morbidities were associated with 30-day/hospital mortality and should be subjected to more research for the purposes of improving outcomes.
Collapse
Affiliation(s)
- Enrico Gallitto
- Vascular Surgery, University of Bologna - DIMEC, Bologna, Italy; Vascular Surgery Unit, IRCCS, University Hospital Policlinico S. Orsola, Bologna, Italy.
| | - Gianluca Faggioli
- Vascular Surgery, University of Bologna - DIMEC, Bologna, Italy; Vascular Surgery Unit, IRCCS, University Hospital Policlinico S. Orsola, Bologna, Italy
| | - Martin Austermann
- Department of Vascular and Endovascular Surgery, St. Franziskus Hospital, Münster, Germany
| | - Tilo Kölbel
- German Aortic Center, Department of Vascular Medicine, University Medical Center Eppendorf (UKE), Hamburg, Germany
| | - Nikolas Tsilimparis
- Department of Vascular Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Nuno Dias
- Vascular Centre, Department of Thoracic Surgery and Vascular Diseases, Skåne University Hospital and Department of Clinical Sciences Malmö, Lund University, Malmö, Sweden
| | - Germano Melissano
- Division of Vascular Surgery, Vita - Salute University, Scientific Institute H. San Raffaele, Milan, Italy
| | - Gioele Simonte
- Vascular and Endovascular Surgery Unit, Hospital S. Maria Misericordia, University of Perugia, Perugia, Italy
| | | | - Kyriakos Oikonomou
- Vascular and Endovascular Surgery, University Hospital and Wolfgang Goethe University Frankfurt, Frankfurt, Germany
| | - Kevin Mani
- Division of Vascular Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Luis Mendes Pedro
- Department of Vascular Surgery, Centro Hospitalar Universitário Lisboa Norte, Faculdade de Medicina da Universidade de Lisboa, Centro Cardiovascular da Universidade de Lisboa, Lisbon, Portugal
| | - Fabrizio Cecere
- Vascular Surgery, University of Bologna - DIMEC, Bologna, Italy
| | - Stephan Haulon
- Vascular Surgery, Hospital Marie Lannelongue, Paris, France
| | - Mauro Gargiulo
- Vascular Surgery, University of Bologna - DIMEC, Bologna, Italy; Vascular Surgery Unit, IRCCS, University Hospital Policlinico S. Orsola, Bologna, Italy
| |
Collapse
|
9
|
Chen Y, Bashir M, Guo J, Piffaretti G, Jubouri M, D'Oria M. Expert-Based Narrative Review on Contemporary Use of an Off-The-Shelf Multibranched Endograft for Endovascular Treatment of Thoracoabdominal Aortic Aneurysms: Device Design, Anatomical Suitability, Technical Tips, Perioperative Care, Clinical Applications, and Real-World Experience. Ann Vasc Surg 2024; 108:98-111. [PMID: 38942377 DOI: 10.1016/j.avsg.2024.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 05/10/2024] [Accepted: 05/15/2024] [Indexed: 06/30/2024]
Abstract
Advanced endovascular techniques, such as fenestrated stent grafts, are nowadays available that permit minimally invasive treatment of complex abdominal aortic aneurysms. However, thoracoabdominal aortic aneurysm patients have anatomic limitations to fenestrated stent-grafts given a large lumen, that is, the gap between the endograft and the inner aortic wall. This has led to the development of branched endovascular aneurysm repair as the ideal option for such patients. The Zenith t-Branch multibranched endograft (Cook Medical, Bloomington, IN), which has been commercially available in Europe to treat thoracoabdominal aortic aneurysm since June 2012, represents a feasible off-the-shelf alternative for treatment of such pathologies, especially in the urgent setting, for patients who cannot wait the time required for manufacturing and delivery of custom-made endografts. The device's anatomical suitability should be considered, especially for female patients with smaller iliofemoral vessels. Several tips may help deal with particularly complex scenarios (such as, for instance, in case of narrow inner aortic lumens or when treating patients with failure of prior endovascular aneurysm repair), and a broad array of techniques and devices must be available to ensure technical and clinical success. Despite promising early outcomes, concerns remain particularly regarding the risk for spinal cord ischemia and further assessment of long-term durability is needed, including the rate of target vessel instability and need for secondary interventions. As the published evidence mainly comes from retrospective registries, it is likely that reported outcomes may suffer from an intrinsic bias as most procedures reported to date have been carried out at high-volume aortic centers. Nonetheless, with the never-ceasing adoption of new and refined techniques, outcomes are expected to ameliorate.
Collapse
Affiliation(s)
- Yonghui Chen
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China.
| | - Mohamad Bashir
- Vascular & Endovascular Surgery, Velindre University NHS Trust, Health & Education Improvement Wales (HEIW), Cardiff, Wales, UK
| | - Jiayin Guo
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Gabriele Piffaretti
- Vascular Surgery Department of Medicine and Surgery, University of Insubria School of Medicine, Varese, Italy
| | - Matti Jubouri
- Vascular & Endovascular Surgery, Velindre University NHS Trust, Health & Education Improvement Wales (HEIW), Cardiff, Wales, UK
| | - Mario D'Oria
- Department of Vascular and Endovascular Surgery, Cardio-Thoraco-Vascular Department, University Hospital of Trieste ASUGI, Trieste, Italy
| |
Collapse
|
10
|
Ferrer C, Borghese O, Orellana B, Mancusi C, Pennetta FF, Coscarella C, Giudice M, Giudice R. Performance of a new generation balloon expandable stent-graft (Gore VBX) as bridging stent for B-EVAR. THE JOURNAL OF CARDIOVASCULAR SURGERY 2024; 65:482-489. [PMID: 39287462 DOI: 10.23736/s0021-9509.24.13071-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/19/2024]
Abstract
BACKGROUND The aim of this study was to report the results of a single-centre experience with a new generation balloon expandable stent-graft (Viabahn VBX; W. L. Gore & Associates, Flagstaff, AZ, USA) as bridging stent in branched endovascular aortic repair (B-EVAR). METHODS This is a retrospective single institution analysis of a prospectively maintained database. All patients undergone implantation of at least one VBX as bridging stent in B-EVAR over the last 5 years (from July 1, 2018, to November 31, 2023) were included. Primary outcomes were technical success, primary and secondary stent patency rate, branch-related reinterventions, and branch instability. Secondary outcomes were clinical success, mortality, and rate of aortic-related reinterventions. RESULTS This study involved 40 patients for a total of 147 VBX stent-grafts implanted in 141 target vessels as bridging stents in B-EVAR (62.5% off-the-shelf and 37.5% custom made devices; 65% with outer branches and 35% with inner branches) for the treatment of 38 (95%) degenerative and 2 (5%) postdissection aneurysms. In 28 cases (70%) a total transfemoral approach was used to deliver the bridging stents. Technical success was 100%. No target vessel was lost intraoperatively. Over a median follow-up of 26.5 months (range 0-74), primary and secondary patency, branch-related reintervention, and branch instability were 98.5% (139/141), 99.3% (140/141), 15% (6/40), and 4.9% (7/141), respectively. Four of the 7 cases of branch instability, all requiring an endovascular correction, were secondary to type Ic endoleak. Clinical success was 97.5% as effect of 1 perioperative death. During the follow-up other 6 patients died, contributing to an overall survival rate of 82.5%. The overall rate of aortic-related reinterventions was 20%. CONCLUSIONS Despite further evaluation is mandatory to determine durability of the VBX in the long-term after B-EVAR, in our experience VBX demonstrated a high flexibility and trackability, excellent stent retention, and outstanding patency over time. A generous distal landing of the bridging stent into the target vessel should be always achieved, whereas possible, to reduce the risk of type Ic endoleak, which seems to be the main cause of branch instability.
Collapse
Affiliation(s)
- Ciro Ferrer
- Unit of Vascular and Endovascular Surgery, San Giovanni - Addolorata Hospital, Rome, Italy -
| | - Ottavia Borghese
- Unit of Vascular and Endovascular Surgery, San Giovanni - Addolorata Hospital, Rome, Italy
| | - Bernardo Orellana
- Unit of Vascular and Endovascular Surgery, San Giovanni - Addolorata Hospital, Rome, Italy
| | - Carlotta Mancusi
- Unit of Vascular and Endovascular Surgery, San Giovanni - Addolorata Hospital, Rome, Italy
| | - Federico F Pennetta
- Unit of Vascular and Endovascular Surgery, San Giovanni - Addolorata Hospital, Rome, Italy
| | - Carlo Coscarella
- Unit of Vascular and Endovascular Surgery, San Giovanni - Addolorata Hospital, Rome, Italy
| | - Marco Giudice
- Unit of Vascular and Endovascular Surgery, San Giovanni - Addolorata Hospital, Rome, Italy
| | - Rocco Giudice
- Unit of Vascular and Endovascular Surgery, San Giovanni - Addolorata Hospital, Rome, Italy
| |
Collapse
|
11
|
Orellana Davila B, Mancusi C, Coscarella C, Spataro C, Carfagna P, Ippoliti A, Giudice R, Ferrer C. Urgent or Emergent Endovascular Aortic Repair of Infective Aortitis. J Clin Med 2024; 13:4669. [PMID: 39200812 PMCID: PMC11354867 DOI: 10.3390/jcm13164669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 07/31/2024] [Accepted: 08/07/2024] [Indexed: 09/02/2024] Open
Abstract
Background: Aortitis is a rare inflammation of the aorta. It can be classified as infective, non-infective, or idiopathic. Infective aortitis can debut as an acute aortic syndrome that needs urgent or emergent treatment. Historically, these kinds of patients have been preferably treated by open surgery, with subsequent lack of information about the endovascular repair. The aim of the present study is to report the results of our experience with the urgent or emergent endovascular repair of infective aortitis with acute presentation. Methods: All consecutive urgent or emergent endovascular repairs, performed between January 2019 and January 2024 for the treatment of infective aortitis, were included. The inclusion criteria were clinical, laboratory, and radiological findings recognized as aortitis risk factors. Patients with graft or endograft infection, aortic fistulae, and mycotic aneurysm were excluded. Primary endpoints were technical success and 30-day and follow-up survival. Early and late major adverse events, any changes in lesion morphology over time, and need for re-intervention were also assessed. Results: A total of 15 patients (14 males and 1 female) with a mean age of 74.2 ± 8.3 were included. All the subjects were treated by endovascular means in an urgent or emergent setting because of a rapidly growing aneurysm, symptomatic lesion, or contained or free aortic rupture. The diagnosis of infective aortitis was confirmed postoperatively by positive blood cultures in all the patients. A rapidly growing or symptomatic lesion was noted in all 15 subjects. Among these there were six (40%) contained and two (13%) free aneurysm ruptures. The endovascular techniques performed were as follows: four thoracic-EVAR (TEVAR), three off-the-shelf branched-EVAR (BEVAR), one Chimney-EVAR (Ch-EVAR), six EVAR with bifurcated graft, and one EVAR with straight tube graft. Technical success was achieved in 100% of the patients. Two patients (13%) died within 30 days after the index procedure. No case of early aortic-related mortality was registered. During a mean follow-up of 31.6 ± 23.1 months (range 1-71), no further death or major adverse event was registered among the remaining 13 alive patients. Re-interventions were performed in three cases (20%). Aneurysm's shrinkage > 5 mm or stability was noted in 10 of the 13 patients who survived the early period after repair. Conclusions: Despite the relative reluctance to use an endograft in an infected area, in our experience the endovascular approach resulted to be feasible, safe, and effective in the treatment of infective aortitis with acute presentation, with acceptable peri-operative and mid-term follow-up outcomes. Further studies are needed to confirm our results.
Collapse
Affiliation(s)
- Bernardo Orellana Davila
- Vascular and Endovascular Surgery Unit, San Giovanni-Addolorata Hospital, 00184 Rome, Italy; (B.O.D.); (C.M.); (C.C.); (C.S.); (R.G.)
| | - Carlotta Mancusi
- Vascular and Endovascular Surgery Unit, San Giovanni-Addolorata Hospital, 00184 Rome, Italy; (B.O.D.); (C.M.); (C.C.); (C.S.); (R.G.)
| | - Carlo Coscarella
- Vascular and Endovascular Surgery Unit, San Giovanni-Addolorata Hospital, 00184 Rome, Italy; (B.O.D.); (C.M.); (C.C.); (C.S.); (R.G.)
| | - Claudio Spataro
- Vascular and Endovascular Surgery Unit, San Giovanni-Addolorata Hospital, 00184 Rome, Italy; (B.O.D.); (C.M.); (C.C.); (C.S.); (R.G.)
| | - Paolo Carfagna
- Clinical Medicine and Infectious Diseases Unit, San Giovanni-Addolorata Hospital, 00184 Rome, Italy;
| | - Arnaldo Ippoliti
- Vascular Surgery Unit, Biomedicine and Prevention Department, University of Rome Tor Vergata, 00133 Rome, Italy;
| | - Rocco Giudice
- Vascular and Endovascular Surgery Unit, San Giovanni-Addolorata Hospital, 00184 Rome, Italy; (B.O.D.); (C.M.); (C.C.); (C.S.); (R.G.)
| | - Ciro Ferrer
- Vascular and Endovascular Surgery Unit, San Giovanni-Addolorata Hospital, 00184 Rome, Italy; (B.O.D.); (C.M.); (C.C.); (C.S.); (R.G.)
| |
Collapse
|
12
|
Piazza M, Squizzato F, Pratesi G, Parlani G, Simonte G, Giudice R, Mansour W, Veraldi GF, Gennai S, Antonello M. Editor's Choice - Outcomes of Off the Shelf Outer Branched Versus Inner Branched Endografts in the Treatment of Thoraco-Abdominal Aortic Aneurysm in the B.R.I.O. (BRanched Inner - Outer) Study Group. Eur J Vasc Endovasc Surg 2024; 68:50-59. [PMID: 38636923 DOI: 10.1016/j.ejvs.2024.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 01/25/2024] [Accepted: 04/10/2024] [Indexed: 04/20/2024]
Abstract
OBJECTIVE This study aimed to compare two commercially available off the shelf branched endografts for thoraco-abdominal aortic aneurysm (TAAA) repair, namely the E-nside (Artivion) and Zenith t-Branch (Cook Medical) devices. METHODS This multicentre retrospective study (2020 - 2023) included patients treated by branched endovascular aortic repair (BEVAR) for TAAA using the inner branched E-nside or the outer branched t-Branch. Endpoints were 30 day technical success and major adverse events (MAEs) as well as one year freedom from target vessel instability and main endograft instability. RESULTS The study included 163 patients: 79 (307 target vessels) treated with E-nside and 84 (325 target vessels) with t-branch. Aneurysm extent was I - III in 91 patients (55.8%; 47% of E-nside and 66% of t-Branch) and IV in 72 patients (44.2%; 53% of E-nside and 34% of t-Branch) (p = .011). An adjunctive proximal thoracic endograft was used in 43% of E-nside vs. 69% of t-Branch (p < .001), with less frequent thoracic endografting (14% vs. 76%; p < .001) and shorter length of coverage (p = .024) in extent IV TAAA treated by E-nside. E-nside cases had shorter renal artery bridging lengths (66 ± 17 mm vs. 76 ± 20 mm; p < .010) and less frequent use of a distal bifurcated endograft (53% vs. 80%; p < .001). Comparing 30 day results, the mortality rate was 1% vs. 2% (p = .62), any MAE occurred in 18% vs. 21% (p = .55), the stroke rate was 3% vs. 0% (p = .23), and the elective spinal cord ischaemia rate was 5% vs. 8% (p = .40) for E-nside and t-Branch, respectively. At one year, freedom from target vessel instability was 96 ± 3% for E-nside and 95 ± 3% for t-Branch (p = .58), and freedom from endograft instability was 98 ± 2% vs. 97 ± 3% (p = .46), respectively. CONCLUSION Both off the shelf devices provided excellent early and one year results. The E-nside may require shorter thoracic aortic coverage and bridging length for the renal arteries, and less frequent implantation of a concomitant proximal thoracic or distal abdominal bifurcated endograft. However, these aspects did not determine significant differences in clinical outcomes.
Collapse
Affiliation(s)
- Michele Piazza
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
| | - Francesco Squizzato
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy. https://www.twitter.com/dr_fsquizzato
| | - Giovanni Pratesi
- Vascular and Endovascular Surgery Unit, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
| | - Gianbattista Parlani
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy
| | - Gioele Simonte
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy
| | - Rocco Giudice
- Vascular and Endovascular Surgery Unit, San Giovanni Addolorata Hospital, Rome, Italy
| | - Wassim Mansour
- Vascular Surgery Division, Department of Surgery "Paride Stefanini", Policlinico Umberto I -"La Sapienza" University of Rome, Rome, Italy
| | | | - Stefano Gennai
- Division of Vascular Surgery, University Hospital of Modena and Reggio Emilia, Baggiovara (MO), Italy
| | - Michele Antonello
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| |
Collapse
|
13
|
Simonte G, Gatta E, Vento V, Parlani G, Simonte R, Montecchiani L, Isernia G. Partial Deployment to Save Space for Vessel Cannulation When Treating Complex Aortic Aneurysms with Narrow Paravisceral Lumen Is Also Feasible Using Inner-Branched Pre-Cannulated Endografts. J Clin Med 2024; 13:3060. [PMID: 38892771 PMCID: PMC11172520 DOI: 10.3390/jcm13113060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 05/21/2024] [Accepted: 05/22/2024] [Indexed: 06/21/2024] Open
Abstract
Introduction: The aim of this paper is to propose a sequential deployment technique for the E-nside off-the-shelf endograft that could potentially enhance target visceral vessel (TVV) cannulation and overstenting in narrow aortic anatomies. Methods: All data regarding patients consecutively treated in two aortic centers with the E-nside graft employing the partial deployment technique were included in the study cohort and analyzed. To execute the procedure with partial endograft deployment, the device should be prepared before insertion by advancing, under fluoroscopy, all four dedicated 400 cm long 0.018″ non-hydrophilic guidewires until their proximal ends reach the cranial graft's edge. Anticipating this guidewire placement prevents the inability to do so once the endograft is partially released, avoiding potentially increased friction inside the constricted pre-loaded microchannels. The endograft is then advanced and deployed in the standard fashion, stopping just after the inner branch outlets are fully expanded. Tip capture is released, and the proximal end of the device is opened. Visceral vessel bridging is completed from an upper access in the desired sequence, and the graft is fully released after revascularizing one or more arteries. Preventing the distal edge of the graft from fully expanding improves visceral vessel cannulation and bridging component advancement, especially when dealing with restricted lumina. Results: A total of 26 patients were treated during the period December 2019-March 2024 with the described approach. Procedure was performed in urgent settings in 14/26 cases. The available lumen was narrower than 24 mm at the origin of at least one target vessel in 11 out of 26 cases performed (42.3%). Technical success was obtained in 24 out of 26 cases (92.3%), with failures being due to TVVs loss. No intraoperative death or surgical conversion was recorded, and no early reintervention was needed in the perioperative period. Clinical success at 30 days was therefore 80.7%. Conclusions: The described technique could be considered effective in saving space outside of the graft, allowing for safe navigation and target vessel cannulation in narrow visceral aortas, similar to what has already been reported for outer-branched endografts.
Collapse
Affiliation(s)
- Gioele Simonte
- Vascular and Endovascular Surgery Unit, S. Maria della Misericordia University Hospital, 06132 Perugia, Italy (R.S.)
| | - Emanuele Gatta
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| | - Vincenzo Vento
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| | - Gianbattista Parlani
- Vascular and Endovascular Surgery Unit, S. Maria della Misericordia University Hospital, 06132 Perugia, Italy (R.S.)
| | - Rachele Simonte
- Vascular and Endovascular Surgery Unit, S. Maria della Misericordia University Hospital, 06132 Perugia, Italy (R.S.)
| | - Luca Montecchiani
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| | - Giacomo Isernia
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| |
Collapse
|
14
|
Piazza M, Squizzato F, Forcella E, Bilato MJ, Colacchio EC, Grego F, Antonello M. Effect of narrow paravisceral aorta on target vessel instability after fenestrated and branched endovascular aortic repair. J Vasc Surg 2024; 79:217-227.e1. [PMID: 37852334 DOI: 10.1016/j.jvs.2023.09.039] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 09/16/2023] [Accepted: 09/22/2023] [Indexed: 10/20/2023]
Abstract
OBJECTIVE To investigate the effect of narrow paravisceral aorta (NPA) on target vessel instability (TVI) after fenestrated-branched endovascular aortic repair. METHODS We conducted a single-center retrospective study (2014-2023) of patients treated by fenestrated-branched endovascular aortic repair for thoracoabdominal aortic aneurysms (TAAA) or pararenal aortic aneurysms. The paravisceral aorta was defined as the aortic segment limited by the diaphragmatic hiatus proximally and the emergence of lower renal artery distally, and was considered "narrow" in case of a minimum inner diameter of <25 mm. The minimum aortic diameter, location, longitudinal extension, angulation, calcification, and thrombus thickness of NPA were evaluated at the preoperative computed tomography angiogram. End points were 30-day technical success and freedom from TVI. RESULTS There were 142 patients with JRAA/pararenal aortic aneurysm (n = 85 [59%]) and extent IV (n = 24 [17%]) or extent I-III (n = 33 [23%]) TAAA, with 513 target arteries successfully incorporated through a fenestration (n = 294 [57%]) or directional branch (n = 219 [43%]). A NPA was present in 95 patients (70%), 73 (86%) treated by fenestrated endovascular aortic repair (FEVAR) and 22 (39%) by branched endovascular aortic repair (BEVAR). The overall 30-day mortality was 2% and technical success was 99%, without differences between NPA and non-NPA (P = .99). Kaplan-Meier estimated freedom from TVI at 4 years was 82%, 81% (95% CI, 75-95) in patients with a NPA and 80% (95% CI, 68-94) and in those without NPA (P = .220). The result was maintained for both FEVAR (NPA: 81% [95% CI, 62-88]; non-NPA: 76% [95% CI, 60-99]; P = .870) and BEVAR (NPA: 77% [95% CI, 69-99]; non-NPA: 80% [95% confidence interval (CI) 66-99]; P = .100). After multivariate analysis, the concomitant presence of a NPA <20 mm and angulation of >30° was significantly associated with TVI in FEVAR (HR, 3.21; 95% CI, 1.03-48.70; P = .036), being the result mostly driven by target vessel occlusion. In BEVAR, a NPA diameter of <25 mm was not associated with TVI (HR, 2.02; 95% CI, 0.59-5.23; P = .948); after multivariate analysis, the use of outer branches in case of a NPA longitudinal extension of >25 mm (hazard ratio [HR], 3.02; 95% CI, 1.01-36.33; P = .040) and NPA severe calcification (HR, 1.70; 95% CI, 1.00-22.42; P = .048) were associated with a higher chance for TVI. CONCLUSIONS FEVAR and BEVAR are both feasible in cases of NPA and provide satisfactory target vessels durability. The use of outer branches should be avoided in cases with an inner aortic diameter of <25 mm with a longitudinal extension of >25 mm or moderate to severe NPA calcifications. In FEVAR, bridging stent patency may be negatively influenced by NPA of <20 mm in association with aortic angulation of >30°.
Collapse
Affiliation(s)
- Michele Piazza
- Vascular and Endovascular Surgery Division, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, Padova University, Padova, Italy.
| | - Francesco Squizzato
- Vascular and Endovascular Surgery Division, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, Padova University, Padova, Italy
| | - Edoardo Forcella
- Vascular and Endovascular Surgery Division, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, Padova University, Padova, Italy
| | - Marco James Bilato
- Vascular and Endovascular Surgery Division, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, Padova University, Padova, Italy
| | - Elda Chiara Colacchio
- Vascular and Endovascular Surgery Division, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, Padova University, Padova, Italy
| | - Franco Grego
- Vascular and Endovascular Surgery Division, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, Padova University, Padova, Italy
| | - Michele Antonello
- Vascular and Endovascular Surgery Division, Department of Cardiac, Thoracic, Vascular Sciences, and Public Health, Padova University, Padova, Italy
| |
Collapse
|
15
|
Chen Y, Liu Z, Wang S, D'Oria M, Zhang X, Bi J, Cui D, Dai X. Systematic Review and Meta-analysis of Short-term and Mid-term Outcomes After Use of t-Branch Off-the-shelf Multibranched Endograft for Elective and Urgent Treatment of Thoracoabdominal Aortic Aneurysms. J Endovasc Ther 2023:15266028231220322. [PMID: 38158706 DOI: 10.1177/15266028231220322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
OBJECTIVE To conduct a meta-analysis to assess the safety and efficacy of t-Branch off-the-shelf multibranched endograft for the treatment of thoracoabdominal aortic aneurysm (TAAA). DATA SOURCES PubMed, Embase, and Web of Science. REVIEW METHODS Online databases were searched from June 2012 to March 2023. The data were pooled together using a random-effects model of proportions. The outcomes overall included technical success, spinal cord ischemia, target vessel occlusion, type I or III endoleak, reintervention, early mortality (30-day), and mid-term outcomes. Subgroup meta-analyses and meta-regression were performed to explore variation among studies. RESULTS A total of 15 studies containing 1238 patients were included in the meta-analysis. The overall study quality assessment was found to be moderate to good. The pooled technical success was 97.0% (95% confidence interval [CI]=95.5-98.6, I2=53.01%, 1185/1238 cases, 15 studies). Overall, early mortality was 7.3% (95% CI=4.4-10.1, I2=74.48%, 124/1238 cases, 15 studies). Early spinal cord ischemia was 13.4% (95% CI=9.6-17.2, I2=67.24%, 160/1238 cases, 15 studies), and early type I or III endoleak was 6.0% (95% CI=3.4-8.5, I2=53.71%, 68/1032 cases, 9 studies). Mid-term outcomes showed target vessel occlusion was 4% (95% CI=1.4-6.5, I2=65.18%, 28/528 cases, 10 studies, 5-21.2 months), type I or III endoleak was 4.7% (95% CI=2-7.5, I2=49.74%, 38/512 cases, 10 studies, 5-21.2 months), reintervention was 11.2% (95% CI=8.1-14.3, I2=31.06%, 85/650 cases, 10 studies, 5-21.2 months), and pooled mortality was 13.9% (95% CI=7.2-20.7, I2=76.32%, 84/550 cases, 11 studies, 5-21.2 months). Meta-regression found a significant linear association between higher technical success and earlier publication year (p=0.014) and studies with anatomic inclusion criteria (p=0.037). Urgent patients (p=0.021) and later publication year (p=0.048) were significantly associated with higher early mortality. CONCLUSION The use of the off-the-shelf t-Branch multibranched endograft for elective or urgent endovascular TAAA repair is associated with high technical success rates and proved to be safe and effective at early and mid-term follow-up. However, the heterogeneity between the included studies is high, and prospective, randomized studies along with future larger studies with long-term follow-up are needed. CLINICAL IMPACT The Zenith t-Branch (Cook Medical, Bloomington, Ind) was approved as a commercially available device in Europe in June 2012. Although a decade has past, the outcomes of t-Branch have rarely been synthesized at the global level. This meta-analysis included 15 studies containing 1238 patients. The meta-analyses included technical success, major adverse events, reintervention, early mortality, and mid-term outcomes. The outcome was very meaningful and representative for the use of t-Branch. It is helpful for endovascular surgeons to make decisions on the treatment of TAAA patients.
Collapse
Affiliation(s)
- Yonghui Chen
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Zongwei Liu
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Shuaishuai Wang
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Mario D'Oria
- Division of Vascular and Endovascular Surgery, Cardio-thoraco-vascular Department, University Hospital of Trieste Azienda Sanitaria Universitaria Giuliano Isontina, Trieste, Italy
| | - Xiaoxing Zhang
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Jiaxue Bi
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Dongsheng Cui
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Xiangchen Dai
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| |
Collapse
|
16
|
Nana P, Spanos K, Jakimowicz T, Torrealba JI, Jama K, Panuccio G, Rohlffs F, Kölbel T. Urgent and emergent repair of complex aortic aneurysms using an off-the-shelf branched device. Front Cardiovasc Med 2023; 10:1277459. [PMID: 37808886 PMCID: PMC10556233 DOI: 10.3389/fcvm.2023.1277459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 09/11/2023] [Indexed: 10/10/2023] Open
Abstract
Introduction Endovascular repair using off-the-shelf endografts is a viable solution in patients with ruptured or symptomatic complex aortic aneurysms. This analysis aimed to present the peri-operative and follow-up outcomes in urgent and emergent cases managed with the t-Branch multibranched thoracoabdominal endograft. Methods Prospectively collected data from all consecutive urgent and emergent cases managed in two aortic centers between January 1st, 2014, to November 30th, 2022, using the t-Branch device (Cook Medical Inc., Bjaeverskov, Denmark) were analyzed. Patients presenting with ruptured aortic complex aneurysms were characterized as emergent and patients with aneurysms >90 mm of diameter, or symptomatic aneurysms were characterized as urgent. Technical success, 30-day mortality, major adverse events (MAE) and spinal cord ischemia (SCI) rates were assessed. Results 225 patients (36.5% females, 72.5 ± 2.8 years) were included; 73.0% were urgent. The mean aneurysm diameter was 109 ± 3.9 mm and 44.4% were type I-III TAAAs. Females (p = .03), para-renal aneurysms (p = .02) and ASA score IV (p < .001) were more common in emergent cases. Technical success was 97.8%. Thirty-day mortality and MAE rates were 17.8% and 30.6%, respectively. SCI rate was 14.7%, (4.8% paraplegia rate) with 22.2% of patients receiving prophylactic cerebrospinal drainage. Thirty-day mortality (13.3% vs. 26.7%, p = .04) and MAE (26.0% vs. 43.0%, p = .02) were more common among emergent cases while technical success (97.6% vs. 98.3%, p = .9), and SCI (13.3% vs. 18.3%, p = .4) were similar. Survival at 12-months was 83.5% (SE 5.9%) for the urgent and 77.1% (SE 8.2%) for the emergent group (log rank, p = 0.96). Conclusion T-Branch represents an effective and safe solution for the management of urgent and emergent cases with complex aortic aneurysms, with high technical success, promising early mortality and SCI rates.
Collapse
Affiliation(s)
- Petroula Nana
- German Aortic Center, Department of Vascular Medicine, University Heart and Vascular Center UKE Hamburg, Hamburg, Germany
| | - Konstantinos Spanos
- German Aortic Center, Department of Vascular Medicine, University Heart and Vascular Center UKE Hamburg, Hamburg, Germany
| | - Tomasz Jakimowicz
- Department of General, Vascular and Transplant Surgery, Medical University of Warsaw, Warsaw, Poland
| | - Jose I. Torrealba
- German Aortic Center, Department of Vascular Medicine, University Heart and Vascular Center UKE Hamburg, Hamburg, Germany
| | - Katarzyna Jama
- Department of General, Vascular and Transplant Surgery, Medical University of Warsaw, Warsaw, Poland
| | - Giuseppe Panuccio
- German Aortic Center, Department of Vascular Medicine, University Heart and Vascular Center UKE Hamburg, Hamburg, Germany
| | - Fiona Rohlffs
- German Aortic Center, Department of Vascular Medicine, University Heart and Vascular Center UKE Hamburg, Hamburg, Germany
| | - Tilo Kölbel
- German Aortic Center, Department of Vascular Medicine, University Heart and Vascular Center UKE Hamburg, Hamburg, Germany
| |
Collapse
|
17
|
Piazza M, Squizzato F, Pratesi G, Tshomba Y, Gaggiano A, Gatta E, Simonte G, Piffaretti G, Frigatti P, Veraldi GF, Silingardi R, Antonello M. Editor's Choice - Early Outcomes of a Novel Off the Shelf Preloaded Inner Branch Endograft for the Treatment of Complex Aortic Pathologies in the ItaliaN Branched Registry of E-nside EnDograft (INBREED). Eur J Vasc Endovasc Surg 2023; 65:811-817. [PMID: 36871927 DOI: 10.1016/j.ejvs.2023.02.076] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 02/02/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023]
Abstract
OBJECTIVE The aim of this study was to investigate the early outcomes of a novel off the shelf pre-loaded inner branched thoraco-abdominal endograft (E-nside) in the treatment of aortic pathologies. METHODS Data from a physician initiated national multicentre registry on patients treated with the E-nside endograft, were prospectively collected and analysed. Pre-operative clinical and anatomical characteristics, procedural data, and early outcomes (90 days) were recorded in a dedicated electronic data capture system. The primary endpoint was technical success. Secondary endpoints were early mortality (90 days), procedural metrics, target vessel patency, endoleak rate, and major adverse events (MAEs) at 90 days. RESULTS In total, 116 patients from 31 Italian centres were included. Mean ± standard deviation (SD) patient age was 73 ± 8 years and 76 (65.5%) were male. Aortic pathologies included degenerative aneurysm in 98 (84.5%), post-dissection aneurysm in five (4.3%), pseudoaneurysm in six (5.2%), penetrating aortic ulcer or intramural haematoma in four (3.4%), and subacute dissection in three (2.6%). Mean ± SD aneurysm diameter was 66 ± 17 mm; aneurysm extent was Crawford I - III in 55 (50.4%), IV in 21 (19.2%), pararenal in 29 (26.7%), and juxtarenal in four (3.7%). The procedure setting was urgent in 25 (21.5%) patients. Median procedural time was 240 minutes (interquartile range [IQR] 195, 303), with a median contrast volume of 175 mL (IQR 120, 235). The endograft's technical success rate was 98.2% and the 90 day mortality rate was 5.2% (n = 6; 2.1% for elective repair and 16% for urgent repair). The 90-days cumulative MAE rate was 24.1% (n = 28). At 90 days, there were 10 (2.3%) target vessel related events (nine occlusions and one type IC endoleak) and one type 1A endoleak requiring re-intervention. CONCLUSION In this real life, non-sponsored registry, the E-nside endograft was used for the treatment of a broad spectrum of aortic pathologies, including urgent cases and different anatomies. The results showed excellent technical implantation safety and efficacy, as well as early outcomes. Longer term follow up is needed to better define the clinical role of this novel endograft.
Collapse
Affiliation(s)
- Michele Piazza
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
| | - Francesco Squizzato
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Giovanni Pratesi
- Vascular and Endovascular Surgery Unit, Ospedale Policlinico San Martino, University of Genoa, Genoa, Italy
| | - Yamume Tshomba
- Unit of Vascular Surgery, Fondazione Policlinico Universitario A. Gemelli I.R.C.C.S., Università Cattolica del Sacro Cuore, Rome, Italy
| | - Andrea Gaggiano
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| | - Emanuele Gatta
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, Ancona, Italy
| | - Gioele Simonte
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy
| | - Gabriele Piffaretti
- Vascular Surgery, Department of Medicine and Surgery, ASST Settelaghi University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy
| | - Paolo Frigatti
- Division of Vascular Surgery, Azienda Sanitaria Universitaria Friuli Centrale, S. Maria della Misericordia University Hospital of Udine, Udine, Italy
| | | | - Roberto Silingardi
- Division of Vascular Surgery, University Hospital of Modena and Reggio Emilia, Baggiovara (MO), Italy
| | - Michele Antonello
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| |
Collapse
|
18
|
Grandi A, Melloni A, D'Oria M, Lepidi S, Bonardelli S, Kölbel T, Bertoglio L. Emergent endovascular treatment options for thoracoabdominal aortic aneurysm. Semin Vasc Surg 2023; 36:174-188. [PMID: 37330232 DOI: 10.1053/j.semvascsurg.2023.04.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/04/2023] [Accepted: 04/04/2023] [Indexed: 06/19/2023]
Abstract
For a long time, parallel grafting, physician-modified endografts, and, more recently, in situ fenestration were the only go-to endovascular options for ruptured thoracoabdominal aortic aneurysm, offered mixed results, and depended mainly on the operator's and center's experience. As custom-made devices have become an established endovascular treatment option for elective thoracoabdominal aortic aneurysm, they are not a viable option in the emergency setting, as endograft production can take up to 4 months. The development of off-the-shelf (OTS) multibranched devices with a standardized configuration has allowed the treatment of ruptured thoracoabdominal aortic aneurysm with emergent branched endovascular procedures. The Zenith t-Branch device (Cook Medical) was the first readily available graft outside the United States to receive the CE mark (in 2012) and is currently the most studied device for those indications. A new device, the E-nside thoracoabdominal branch endoprosthesis OTS multibranched endograft (Artivion), has been made commercially available, and the GORE EXCLUDER thoracoabdominal branch endoprosthesis OTS multibranched endograft (W. L. Gore and Associates) is expected to be released in 2023. Due to the lack of guidelines on ruptured thoracoabdominal aortic aneurysm, this review summarizes the available treatment options (ie, parallel grafts, physician-modified endografts, in situ fenestrations, and OTS multibranched devices), compares the indications and contraindications, and points out the evidence gaps that should be filled in the next decade.
Collapse
Affiliation(s)
- Alessandro Grandi
- Department of Vascular Medicine, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Andrea Melloni
- Division of Vascular Surgery, Department of Clinical and Experimental Sciences, University of Brescia School of Medicine, ASST Spedali Civili of Brescia, Brescia, Italy
| | - Mario D'Oria
- Division of Vascular and Endovascular Surgery, Cardiovascular Department, University Hospital of Trieste Azienda sanitaria universitaria Giuliano Isontina, Trieste, Italy
| | - Sandro Lepidi
- Division of Vascular and Endovascular Surgery, Cardiovascular Department, University Hospital of Trieste Azienda sanitaria universitaria Giuliano Isontina, Trieste, Italy
| | - Stefano Bonardelli
- Division of Vascular Surgery, Department of Clinical and Experimental Sciences, University of Brescia School of Medicine, ASST Spedali Civili of Brescia, Brescia, Italy
| | - Tilo Kölbel
- Department of Vascular Medicine, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Luca Bertoglio
- Division of Vascular Surgery, Department of Clinical and Experimental Sciences, University of Brescia School of Medicine, ASST Spedali Civili of Brescia, Brescia, Italy.
| |
Collapse
|
19
|
Spath P, Tsilimparis N, Furlan F, Hamwi T, Prendes CF, Stana J. Additional Aortic Coverage With an Off The Shelf, Multibranched Endograft Compared With Custom Made Devices For Endovascular Repair of Pararenal Abdominal Aortic Aneurysms. Eur J Vasc Endovasc Surg 2023; 65:710-718. [PMID: 36707021 DOI: 10.1016/j.ejvs.2023.01.030] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 10/07/2022] [Accepted: 01/16/2023] [Indexed: 01/26/2023]
Abstract
OBJECTIVE Pararenal abdominal aortic aneurysms (p-AAA) require complex endovascular aortic repair or open surgical repair with suprarenal clamping. Custom made devices (CMD), including fenestrated and branched endovascular aortic repair (F/B-EVAR) or off the shelf (OTS) multibranched devices, are available treatment options. The aim of this study was to determine the additional healthy aortic coverage using an OTS multibranched endograft vs. a CMD for the treatment of p-AAAs. METHODS This was a retrospective single centre analysis of prospectively collected data. Consecutive patients with p-AAAs requiring a proximal landing zone above the coeliac artery (CA), planned and treated with CMDs (Zenith Fenestrated) between January 2017 and December 2021 were included in this study. Treatment with supracoeliac coverage using available OTS multibranched devices was simulated using available pre-operative images: T-Branch; E-nside; and TAMBE. Study endpoints included the need for additional proximal aortic coverage, and the number of the segmental arteries additionally covered proximally from the CA for OTS devices compared with CMDs. RESULTS Eighty three patients with p-AAAs were treated with CMDs (all FEVAR), including juxtarenal AAAs (n = 46; 56%), suprarenal AAAs (n = 20; 24%), and short neck AAAs (n = 17; 20%). In this study, treatment with 249 (3 × 83) OTS endografts was simulated. When compared with CMDs, OTS devices required a mean of 74 ± 19 mm of additional proximal healthy aortic coverage from the CA (CMD: 33 ± 19 mm vs. OTS: 108 ± 6 mm; p ≤ .001), as well as an average sacrifice of 2.5 additional segmental arteries (CMD: 1.3 ± 0.8 vs. OTS: 3.8 ± 0.9; p ≤ .001). In 94% of patients, at least one of the available multibranched endografts could have been implanted in accordance with instructions for use. CONCLUSION Despite not requiring customisation time, OTS endografts for the treatment of p-AAA lead to more extensive healthy aortic coverage, as well as an average sacrifice of 2.5 additional segmental arteries, compared with CMDs. When compared with OTS devices, CMDs appear to limit the extent of unnecessary aortic coverage and the theoretical subsequent risk of spinal cord ischaemia.
Collapse
Affiliation(s)
- Paolo Spath
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| | - Nikolaos Tsilimparis
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany.
| | - Federico Furlan
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| | - Tarek Hamwi
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| | - Carlota F Prendes
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| | - Jan Stana
- Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
| |
Collapse
|