1
|
Nix Z, Kota D, Ratnayake I, Wang C, Smith S, Wood S. Spectral characterization of cell surface motion for mechanistic investigations of cellular mechanobiology. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2022; 176:3-15. [PMID: 36108781 DOI: 10.1016/j.pbiomolbio.2022.08.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 07/27/2022] [Accepted: 08/05/2022] [Indexed: 06/15/2023]
Abstract
Understanding the specific mechanisms responsible for anabolic and catabolic responses to static or dynamic force are largely poorly understood. Because of this, most research groups studying mechanotransduction due to dynamic forces employ an empirical approach in deciding what frequencies to apply during experiments. While this has been shown to elucidate valuable information regarding how cells respond under controlled provocation, it is often difficult or impossible to determine a true optimal frequency for force application, as many intracellular complexes are involved in receiving, propagating, and responding to a given stimulus. Here we present a novel adaptation of an analytical technique from the fields of civil and mechanical engineering that may open the door to direct measurement of mechanobiological cellular frequencies which could be used to target specific cell signaling pathways leveraging synergy between outside-in and inside-out mechanotransduction approaches. This information could be useful in identifying how specific proteins are involved in the homeostatic balance, or disruption thereof, of cells and tissue, furthering the understanding of the pathogenesis and progression of many diseases across a wide variety of cell types, which may one day lead to the development of novel mechanobiological therapies for clinical use.
Collapse
Affiliation(s)
- Zachary Nix
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Divya Kota
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Ishara Ratnayake
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Congzhou Wang
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Steve Smith
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Scott Wood
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA.
| |
Collapse
|
2
|
Bezerra A, Freitas L, Maciel L, Fonseca H. Bone Tissue Responsiveness To Mechanical Loading-Possible Long-Term Implications of Swimming on Bone Health and Bone Development. Curr Osteoporos Rep 2022; 20:453-468. [PMID: 36401774 DOI: 10.1007/s11914-022-00758-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/29/2022] [Indexed: 11/21/2022]
Abstract
PURPOSE OF REVIEW To revisit the bone tissue mechanotransduction mechanisms behind the bone tissue response to mechanical loading and, within this context, explore the possible negative influence of regular swimming practice on bone health, particularly during the growth and development period. RECENT FINDINGS Bone is a dynamic tissue, responsive to mechanical loading and unloading, being these adaptative responses more intense during the growth and development period. Cross-sectional studies usually report a lower bone mass in swimmers compared to athletes engaged in weigh-bearing sports. However, studies with animal models show contradictory findings about the effect of swimming on bone health, highlighting the need for longitudinal studies. Due to its microgravity characteristics, swimming seems to impair bone mass, but mostly at the lower limbs. It is unkown if there is a causal relationship between swimming and low BMD or if other confounding factors, such as a natural selection whithin the sport, are the cause.
Collapse
Affiliation(s)
- Andréa Bezerra
- Research Centre in Physical Activity, Health and Leisure (CIAFEL), Faculty of Sport, University of Porto (FADE/UP), 4200-450, Porto, Portugal.
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600, Porto, Portugal.
| | - Laura Freitas
- Research Centre in Physical Activity, Health and Leisure (CIAFEL), Faculty of Sport, University of Porto (FADE/UP), 4200-450, Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600, Porto, Portugal
| | - Leonardo Maciel
- Research Centre in Physical Activity, Health and Leisure (CIAFEL), Faculty of Sport, University of Porto (FADE/UP), 4200-450, Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600, Porto, Portugal
- Department of Physiotherapy, Federal University of Sergipe, Campus Lagarto, Lagarto, Brazil
| | - Hélder Fonseca
- Research Centre in Physical Activity, Health and Leisure (CIAFEL), Faculty of Sport, University of Porto (FADE/UP), 4200-450, Porto, Portugal
- Laboratory for Integrative and Translational Research in Population Health (ITR), 4050-600, Porto, Portugal
| |
Collapse
|
3
|
Sutor TW, Kura J, Mattingly AJ, Otzel DM, Yarrow JF. The Effects of Exercise and Activity-Based Physical Therapy on Bone after Spinal Cord Injury. Int J Mol Sci 2022; 23:608. [PMID: 35054791 PMCID: PMC8775843 DOI: 10.3390/ijms23020608] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 12/15/2021] [Accepted: 12/21/2021] [Indexed: 02/04/2023] Open
Abstract
Spinal cord injury (SCI) produces paralysis and a unique form of neurogenic disuse osteoporosis that dramatically increases fracture risk at the distal femur and proximal tibia. This bone loss is driven by heightened bone resorption and near-absent bone formation during the acute post-SCI recovery phase and by a more traditional high-turnover osteopenia that emerges more chronically, which is likely influenced by the continual neural impairment and musculoskeletal unloading. These observations have stimulated interest in specialized exercise or activity-based physical therapy (ABPT) modalities (e.g., neuromuscular or functional electrical stimulation cycling, rowing, or resistance training, as well as other standing, walking, or partial weight-bearing interventions) that reload the paralyzed limbs and promote muscle recovery and use-dependent neuroplasticity. However, only sparse and relatively inconsistent evidence supports the ability of these physical rehabilitation regimens to influence bone metabolism or to increase bone mineral density (BMD) at the most fracture-prone sites in persons with severe SCI. This review discusses the pathophysiology and cellular/molecular mechanisms that influence bone loss after SCI, describes studies evaluating bone turnover and BMD responses to ABPTs during acute versus chronic SCI, identifies factors that may impact the bone responses to ABPT, and provides recommendations to optimize ABPTs for bone recovery.
Collapse
Affiliation(s)
- Tommy W. Sutor
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL 32608, USA; (T.W.S.); (J.K.)
- Brain Rehabilitation Research Center, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL 32608, USA;
| | - Jayachandra Kura
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL 32608, USA; (T.W.S.); (J.K.)
| | - Alex J. Mattingly
- Geriatrics Research, Education, and Clinical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL 32608, USA;
| | - Dana M. Otzel
- Brain Rehabilitation Research Center, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL 32608, USA;
| | - Joshua F. Yarrow
- Research Service, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL 32608, USA; (T.W.S.); (J.K.)
- Brain Rehabilitation Research Center, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL 32608, USA;
- Division of Endocrinology, Diabetes, and Metabolism, University of Florida College of Medicine, Gainesville, FL 32611, USA
| |
Collapse
|
4
|
Inoue S, Hatakeyama J, Aoki H, Kuroki H, Niikura T, Oe K, Fukui T, Kuroda R, Akisue T, Moriyama H. Utilization of Mechanical Stress to Treat Osteoporosis: The Effects of Electrical Stimulation, Radial Extracorporeal Shock Wave, and Ultrasound on Experimental Osteoporosis in Ovariectomized Rats. Calcif Tissue Int 2021; 109:215-229. [PMID: 33751141 DOI: 10.1007/s00223-021-00831-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 02/24/2021] [Indexed: 11/27/2022]
Abstract
Current treatment options for osteoporosis primarily involve pharmacotherapies, but they are often accompanied by undesirable side effects. Utilization of mechanical stress which can noninvasively induce bone formation has been suggested as an alternative to conventional treatments. Here, we examined the efficacy of mechanical stress induced by electrical stimulation, radial extracorporeal shock waves, and ultrasound for estrogen-deficient osteoporosis. Female Wistar rats were divided into following five groups: sham-operated group, untreated after ovariectomy, and treated with electrical stimulation, radial extracorporeal shock wave, or ultrasound starting at 8 weeks after ovariectomy for 4 weeks. Trabecular bone architecture of the femur was assessed by micro-CT and its biomechanical properties were obtained by mechanical testing. The femurs were further evaluated by histochemical, immunohistochemical, and real-time PCR analyses. Radial extracorporeal shock wave and ultrasound treatment improved trabecular bone microarchitecture and bone strength in osteoporotic rats, but not electrical stimulation. The shock wave decreased osteoclast activity and RANKL expression. The exposure of ultrasound increased osteoblast activity and β-catenin-positive cells, and they decreased sclerostin-positive osteocytes. These findings suggest that mechanical stress induced by radial extracorporeal shock wave and ultrasound can improve estrogen-deficient bone loss and bone fragility through promoted bone formation or attenuated bone resorption.
Collapse
Affiliation(s)
- Shota Inoue
- Department of Rehabilitation Science, Graduate School of Health Sciences, Kobe University, Kobe, Japan
| | - Junpei Hatakeyama
- Department of Rehabilitation Science, Graduate School of Health Sciences, Kobe University, Kobe, Japan
| | - Hitoshi Aoki
- OG Wellness Technologies Co., Ltd, Okayama, Japan
| | - Hiroshi Kuroki
- Department of Physical Therapy, Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Takahiro Niikura
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Keisuke Oe
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Tomoaki Fukui
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Ryosuke Kuroda
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Toshihiro Akisue
- Life and Medical Sciences Area, Health Sciences Discipline, Kobe University, Tomogaoka 7-10-2, Suma-ku, Kobe, Hyogo, 654-0142, Japan
| | - Hideki Moriyama
- Life and Medical Sciences Area, Health Sciences Discipline, Kobe University, Tomogaoka 7-10-2, Suma-ku, Kobe, Hyogo, 654-0142, Japan.
| |
Collapse
|
5
|
DeLong A, Friedman MA, Tucker SM, Krause AR, Kunselman A, Donahue HJ, Lewis GS. Protective Effects of Controlled Mechanical Loading of Bone in C57BL6/J Mice Subject to Disuse. JBMR Plus 2019; 4:e10322. [PMID: 32161839 PMCID: PMC7059829 DOI: 10.1002/jbm4.10322] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Revised: 11/07/2019] [Accepted: 11/19/2019] [Indexed: 11/24/2022] Open
Abstract
Prolonged reduction in weightbearing causes bone loss. Disuse of bone is associated with recovery from common musculoskeletal injury and trauma, bed rest resulting from various medical conditions, and spaceflight. The hindlimb‐suspension rodent model is popular for simulating unloading and disuse. We hypothesized that controlled mechanical loading of the tibia would protect against bone loss occurring from concurrent disuse. Additionally, we hypothesized that areas of high mechanical peak strains (midshaft) would provide more protection than areas of lower strain (distal shaft). Adult C57BL6/J mice were suspended for 3 weeks, with one limb subjected to tibial compression four times per week. μCT imaging was completed at days 0, 11, and 21, in addition to serum analysis. Significant bone loss caused by hindlimb suspension was detected in trabecular bone by day 11 and worsened by day 21 (p < 0.05). Bone loss was also detected in cortical thickness and area fraction by day 21. However, four short bouts per week of compressive loading protected the loaded limb from much of this bone loss. At day 21, we observed a 50% loss in trabecular bone volume/total volume and a 6% loss in midshaft cortical thickness in unloaded limbs, but only 15% and 2% corresponding losses in contralateral loaded limbs (p = 0.001 and p = 0.02). Many bone geometry parameters of the loaded limbs of suspended animals did not significantly differ from non‐suspended control limbs. Conversely, this protective effect of loading was not detected in cortical bone at the lower‐strained distal shaft. Analysis of bone metabolism markers suggested that the benefits of loading occurred through increased formation instead of decreased resorption. This study uniquely isolates the role of externally applied mechanical loading of the mouse tibia, in the absence of muscle stimulation, in protecting bone from concurrent disuse‐related loss, and demonstrates that limited bouts of loading may be highly effective during prolonged disuse. © 2019 The Authors. JBMR Plus published by Wiley Periodicals, Inc. on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Alex DeLong
- Department of Comparative Medicine Pennsylvania State University, College of Medicine Hershey PA USA
| | - Michael A Friedman
- Department of Biomedical Engineering Virginia Commonwealth University Richmond VA USA
| | - Scott M Tucker
- Department of Orthopaedics & Rehabilitation, & Center for Orthopaedic Research and Translational Science Pennsylvania State University, College of Medicine Hershey PA USA
| | - Andrew R Krause
- Department of Orthopaedics & Rehabilitation, & Center for Orthopaedic Research and Translational Science Pennsylvania State University, College of Medicine Hershey PA USA
| | - Allen Kunselman
- Department of Public Health Sciences Pennsylvania State University, College of Medicine Hershey PA USA
| | - Henry J Donahue
- Department of Biomedical Engineering Virginia Commonwealth University Richmond VA USA
| | - Gregory S Lewis
- Department of Orthopaedics & Rehabilitation, & Center for Orthopaedic Research and Translational Science Pennsylvania State University, College of Medicine Hershey PA USA
| |
Collapse
|
6
|
Tamaki H, Yotani K, Ogita F, Hayao K, Kirimto H, Onishi H, Kasuga N, Yamamoto N. Low-Frequency Electrical Stimulation of Denervated Skeletal Muscle Retards Muscle and Trabecular Bone Loss in Aged Rats. Int J Med Sci 2019; 16:822-830. [PMID: 31337955 PMCID: PMC6643115 DOI: 10.7150/ijms.32590] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Accepted: 05/02/2019] [Indexed: 01/25/2023] Open
Abstract
Electrical stimulation (ES)-induced muscle contraction has multiple effects; however, mechano-responsiveness of bone tissue declines with age. Here, we investigated whether daily low-frequency ES-induced muscle contraction treatment reduces muscle and bone loss and ameliorates bone fragility in early-stage disuse musculoskeletal atrophy in aged rats. Twenty-seven-month-old male rats were assigned to age-matched groups comprising the control (CON), sciatic nerve denervation (DN), or DN with direct low-frequency ES (DN+ES) groups. The structural and mechanical properties of the trabecular and cortical bone of the tibiae, and the morphological and functional properties of the tibialis anterior (TA) muscles were assessed one week after DN. ES-induced muscle contraction force mitigated denervation-induced muscle and trabecular bone loss and deterioration of the mechanical properties of the tibia mid-diaphysis, such as the stiffness, but not the maximal load, in aged rats. The TA muscle in the DN+ES group showed significant improvement in the myofiber cross-sectional area and muscle force relative to the DN group. These results suggest that low-frequency ES-induced muscle contraction treatment retards trabecular bone and muscle loss in aged rats in early-stage disuse musculoskeletal atrophy, and has beneficial effects on the functional properties of denervated skeletal muscle.
Collapse
Affiliation(s)
- Hiroyuki Tamaki
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Japan.,Department of Sports and Life Science, National Institute of Fitness and Sports in Kanoya, Japan
| | - Kengo Yotani
- Department of Sports and Life Science, National Institute of Fitness and Sports in Kanoya, Japan
| | - Futoshi Ogita
- Department of Sports and Life Science, National Institute of Fitness and Sports in Kanoya, Japan
| | - Keishi Hayao
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Japan
| | - Hikari Kirimto
- Department of Sensorimotor Neuroscience, Hiroshima University, Japan
| | - Hideaki Onishi
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Japan
| | | | - Noriaki Yamamoto
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Japan.,Niigata Rehabilitation Hospital, Japan
| |
Collapse
|
7
|
He Y, Wang S, Mu J, Dai L, Zhang Z, Sun Y, Shi W, Ge D. Synthesis of polypyrrole nanowires with positive effect on MC3T3-E1 cell functions through electrical stimulation. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 71:43-50. [DOI: 10.1016/j.msec.2016.09.067] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Revised: 08/21/2016] [Accepted: 09/28/2016] [Indexed: 10/20/2022]
|
8
|
Hu M, Tian GW, Gibbons DE, Jiao J, Qin YX. Dynamic fluid flow induced mechanobiological modulation of in situ osteocyte calcium oscillations. Arch Biochem Biophys 2015; 579:55-61. [PMID: 26045248 DOI: 10.1016/j.abb.2015.05.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Revised: 05/23/2015] [Accepted: 05/27/2015] [Indexed: 01/20/2023]
Abstract
Distribution of intramedullary pressure (ImP) induced bone fluid flow has been suggested to influence the magnitude of mechanotransductory signals within bone. As osteocytes have been suggested as major mechanosensors in bone network, it is still unclear how osteocytes embedded within a mineralized bone matrix respond to the external mechanical stimuli derived from direct coupling of dynamic fluid flow stimulation (DFFS). While in vitro osteocytes show unique Ca(2+) oscillations to fluid shear, the objective of this study was to use a confocal imaging technique to visualize and quantify Ca(2+) responses in osteocytes in situ under DFFS into the marrow cavity of an intact ex vivo mouse femur. This study provided significant technical development for evaluating mechanotransduction mechanism in bone cell response by separation of mechanical strain and fluid flow factors using ImP stimulation, giving the ability for true real-time imaging and monitoring of bone cell activities during the stimulation. Loading frequency dependent Ca(2+) oscillations in osteocytes indicated the optimized loading at 10Hz, where such induced response was significantly diminished via blockage of the Wnt/β-catenin signaling pathway. The results provided a pilot finding of the potential crosstalk or interaction between Wnt/β-catenin signaling and Ca(2+) influx signaling of in situ osteocytes in response to mechanical signals. Findings from the present study make a valuable tool to investigate how in situ osteocytes respond and transduce mechanical signals, e.g. DFFS, as a central mechanosensor.
Collapse
Affiliation(s)
- Minyi Hu
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281, United States
| | - Guo-Wei Tian
- CMIC-Two Photon Imaging Center, Stony Brook University, Stony Brook, NY 11794-5200, United States
| | - Daniel E Gibbons
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281, United States
| | - Jian Jiao
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281, United States
| | - Yi-Xian Qin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281, United States.
| |
Collapse
|
9
|
Hu M, Cheng J, Qin YX. Dynamic hydraulic flow stimulation on mitigation of trabecular bone loss in a rat functional disuse model. Bone 2012; 51:819-25. [PMID: 22820398 PMCID: PMC3437383 DOI: 10.1016/j.bone.2012.06.030] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2012] [Revised: 06/21/2012] [Accepted: 06/25/2012] [Indexed: 11/20/2022]
Abstract
Bone fluid flow (BFF) has been demonstrated as a critical regulator in mechanotransductive signaling and bone adaptation. Intramedullary pressure (ImP) and matrix strain have been identified as potential generators to regulate BFF. To elevate in vivo oscillatory BFF using ImP, a dynamic hydraulic stimulation (DHS) approach was developed. The objective of this study was to evaluate the effects of DHS on mitigation of bone loss and structural alteration in a rat hindlimb suspension (HLS) functional disuse model. Sixty-one 5-month old female Sprague-Dawley rats were divided into five groups: 1) baseline control, 2) age-matched control, 3) HLS, 4) HLS+static loading, and 5) HLS+DHS. Hydraulic flow stimulation was carried out daily on a "10 min on-5 min off-10 min on" loading regime, 5 days/week, for a total of 4 weeks in the tibial region. The metaphyseal trabecular regions of the proximal tibiae were analyzed using μCT and histomorphometry. Four weeks of HLS resulted in a significant loss of trabecular bone, leading to structural deterioration. HLS with static loading alone was not sufficient to attenuate the bone loss. Bone quantity and microarchitecture were significantly improved by applying DHS loading, resulting increase of 83% in bone volume fraction, 25% in trabecular number and mitigation of 26% in trabecular separation compared to HLS control. Histomorphometry analysis on trabecular mineralization coincided with the μCT analysis, in which DHS loading yielded increases of 34% in histomorphometric BV/TV, 121% in MS/BS, 190% in BFR/BS and 146% in BFR/BV, compared to the HLS control. Overall, the data demonstrated that dynamic hydraulic flow loading has potentials to provide regulatory signals for mitigating bone loss induced by functional disuse. This approach may provide a new alternative mechanical intervention for future clinical treatment for osteoporosis.
Collapse
Affiliation(s)
| | | | - Yi-Xian Qin
- Corresponding Author: Yi-Xian Qin, Ph.D., Dept. of Biomedical Engineering, Stony Brook University, Bioengineering Bldg., Rm 215, Stony Brook, NY 11794-5281, Phone: 631-632-1481, Fax: 631-632-8577,
| |
Collapse
|
10
|
Involvement of Wnt activation in the micromechanical vibration-enhanced osteogenic response of osteoblasts. J Orthop Sci 2011; 16:598-605. [PMID: 21833614 DOI: 10.1007/s00776-011-0124-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2011] [Accepted: 06/13/2011] [Indexed: 02/05/2023]
Abstract
BACKGROUND Low-magnitude vibration has been widely used as a tool for rehabilitation, enhancing physical performance, and stimulating bone development. Although mechanical stimulation generated by vibrations is regarded as important factor in bone remodeling, the underlying cellular and molecular regulatory mechanisms of this response, which may be important in the development of new mechanobiological strategies, currently remain unclear. METHODS In this study, to investigate the mechanobiological mechanisms of vibration-enhanced osteogenic responses in osteoblasts, MC3T3-E1 cells were subjected to vibrations of different amplitude (0.06, 0.14, 0.32, 0.49, 0.66, and 0.8 × g) at 40 Hz for 30 min/day over 3 days. The osteogenesis-related transcription factors Wnt10B, Sclerostin, OPG, and RANKL were analyzed for mRNA and protein expression. RESULTS The results revealed that protein expression of Wnt10B and OPG was increased in a magnitude-dependent manner by mechanical vibrations at amplitudes of 0.06, 0.14, 0.32, and 0.49 × g; the maximum increases were 2.4-fold (p < 0.001) and 7.9-fold (p < 0.001), respectively, at 0.49 × g. Sclerostin and RANKL levels were reduced at all amplitudes. On the basis of mRNA levels, the reduced expression of RANKL was further downregulated (p < 0.05) whereas OPG expression was further increased (p < 0.01) when the MC3T3-E1 cells were treated with LiCl compared with the effects of vibration alone. CONCLUSIONS The findings may indicate that Wnt signaling is involved in mechanotransduction at low-magnitude vibration; this may provide a cellular basis, and impetus for further development of, biomechanically based intervention for enhancing bone strength and accelerating implant osseointegration.
Collapse
|
11
|
de Jong WC, Korfage JAM, Langenbach GEJ. The role of masticatory muscles in the continuous loading of the mandible. J Anat 2011; 218:625-36. [PMID: 21492160 DOI: 10.1111/j.1469-7580.2011.01375.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Muscles are considered to play an important role in the ongoing daily loading of bone, especially in the masticatory apparatus. Currently, there are no measurements describing this role over longer periods of time. We made simultaneous and wireless in vivo recordings of habitual strains of the rabbit mandible and masseter muscle and digastric muscle activity up to ∼25 h. The extent to which habitually occurring bone strains were related to muscle-activity bursts in time and in amplitude is described. The data reveal the masseter muscle to load the mandible almost continuously throughout the day, either within cyclic activity bouts or with thousands of isolated muscle bursts. Mandibular strain events rarely took place without simultaneous masseter activity, whereas the digastric muscle only played a small role in loading the mandible. The average intensity of masseter-muscle activity bouts was strongly linked to the average amplitude of the concomitant bone-strain events. However, individual pairs of muscle bursts and strain events showed no relation in amplitude within cyclic loading bouts. Larger bone-strain events, presumably related to larger muscle-activity levels, had more constant principal-strain directions. Finally, muscle-to-bone force transmissions were detected to take place at frequencies up to 15 Hz. We conclude that in the ongoing habitual loading of the rabbit mandible, the masseter muscle plays an almost non-stop role. In addition, our results support the possibility that muscle activity is a source of low-amplitude, high-frequency bone loading.
Collapse
Affiliation(s)
- W C de Jong
- Department of Oral Cell Biology and Functional Anatomy, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, MOVE Research Institute, Amsterdam, The Netherlands
| | | | | |
Collapse
|
12
|
Simulated resistance training during hindlimb unloading abolishes disuse bone loss and maintains muscle strength. J Bone Miner Res 2010; 25:564-74. [PMID: 19653816 DOI: 10.1359/jbmr.090811] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
This study was designed to determine the effectiveness of simulated resistance training (SRT) without weight bearing in attenuating bone and muscle loss during 28 day hindlimb unloading (HU) in mature male rats. An ambulatory control group (CC) and four groups of HU rats were used: HU, HU + anesthesia (ANHU), HU + eccentric muscle contractions (HU + ECC), and HU + isometric and eccentric muscle contractions (HU + ISO/ECC). Animals in the two SRT groups were trained once every other day at 100% daily peak isometric torque (P(0)). HU resulted in significantly lower plantarflexor muscle mass (-33% versus CC) and reduced isometric strength (-10%), which reductions were partially attenuated in both training groups. Significantly reduced total and cancellous volumetric bone mineral density (vBMD) and total bone mineral content (BMC) at the proximal tibia metaphysis (PTM) also was evidenced in HU and ANHU groups compared with both SRT groups (p < .05). Training resulted in greater increases in cortical bone mass and area compared with all other groups (p < .05). Fourfold higher material properties of PTM cancellous bone were demonstrated in SRT animals versus HU or CC animals. A significant reduction in midshaft periosteal bone formation rate (BFR) in the HU group (-99% versus CC) was completely abolished in HU + ECC (+656% versus CC). These results demonstrate that high-intensity muscle contractions, independent of weight-bearing forces, can effectively mitigate losses in muscle strength and provide a potent stimulus to bone during prolonged disuse.
Collapse
|
13
|
Qin YX, Lam H. Intramedullary pressure and matrix strain induced by oscillatory skeletal muscle stimulation and its potential in adaptation. J Biomech 2009; 42:140-5. [PMID: 19081096 PMCID: PMC2975034 DOI: 10.1016/j.jbiomech.2008.10.018] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2008] [Revised: 09/04/2008] [Accepted: 10/13/2008] [Indexed: 11/15/2022]
Abstract
Intramedullary pressure (ImP) and low-level bone strain induced by oscillatory muscle stimulation (MS) has the potential to mitigate bone loss induced by disuse osteopenia, i.e., hindlimb suspension (HLS). To test this hypothesis, we evaluated (a) MS-induced ImP and bone strain as function of stimulation frequency and (b) the adaptive responses to functional disuse, and disuse plus 1 and 20 Hz stimulation in vivo. Femoral ImP and bone strain generated by MS were measured in the frequencies of 1-100 Hz in four rats. Forty retired breeder rats were used for the in vivo HLS study. The quadriceps muscle was stimulated at frequencies of 1 and 20 Hz, 10 min/d for four weeks. The metaphyseal trabecular bone quantity and microstructure at the distal femur were evaluated using microCT, while bone formation indices were analyzed using histomorphometric technique. Oscillatory MS generated a maximum ImP of 45+/-9 mmHg at 20 Hz and produced a maximum matrix strain of 128+/-19 microepsilon at 10 Hz. Our analyses from the in vivo study showed that MS at 20 Hz was able to attenuate trabecular bone loss and partially maintain the microstructure induced by HLS. Conversely, there was no evidence of an adaptive effect of stimulation at 1 Hz on disused skeleton. The results suggested that oscillatory MS regulates fluid dynamics and mechanical strain in bone, which serves as a critical mediator of adaptation. These results clearly demonstrated the ability of MS in attenuating bone loss from the disuse osteopenia, which may hold potential in mitigating skeletal degradation imposed by conditions of disuse, and may serve as a biomechanical intervention in clinic application.
Collapse
Affiliation(s)
- Yi-Xian Qin
- Department of Biomedical Engineering, State University of New York at Stony Brook, 350 Psychology-A Building, Stony Brook, NY 11794-2580, USA.
| | | |
Collapse
|
14
|
Lam H, Qin YX. The effects of frequency-dependent dynamic muscle stimulation on inhibition of trabecular bone loss in a disuse model. Bone 2008; 43:1093-100. [PMID: 18757047 PMCID: PMC2642608 DOI: 10.1016/j.bone.2008.07.253] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2008] [Revised: 07/24/2008] [Accepted: 07/30/2008] [Indexed: 10/21/2022]
Abstract
Clinical electrical muscle stimulation has been shown to alleviate muscle atrophy resulting from functional disuse, yet little is known about its effect on the skeleton. The objective of this study is to evaluate the potential of dynamic muscle stimulation on disused trabecular bone, and to investigate the importance of optimized stimulation frequency in the loading regimen. Fifty-six skeletally mature Sprague-Dawley rats were divided into seven groups for the 4-week experiment: baseline control, age-matched control, hindlimb suspended (HLS), and HLS with muscle stimulation at 1 Hz, 20 Hz, 50 Hz, and 100 Hz. Muscle stimulation was carried out for 10 min per day for 5 days per week, total of 4 weeks. The metaphyseal and epiphyseal trabecular regions of the distal femurs were analyzed with microcomputed tomography and histomorphometry methods. HLS alone for 4-week resulted in a significant amount of trabecular bone loss and structural deterioration. Muscle contraction at 1 Hz was not sufficient to inhibit trabecular bone loss and resulted in similar amount of loss to that of HLS alone. Bone quantity and structure were significantly improved by applying muscle stimulation at mid-frequency (20 Hz and 50 Hz). Dynamic stimulation at 50 Hz demonstrated the greatest preventive effect on the skeleton against functional disused alone animals (up to +147% in bone volume fraction, +38% in trabecular number and -36% in trabecular separation). Histomorphometric analysis showed that the stimulation, regardless of its frequency, did not have an effect on the bone formation indices, such as mineral apposition rate and bone formation rate. Overall, the data demonstrated the potentials of frequency-dependent dynamic muscle contraction in regulating skeletal adaptive responses under disuse conditions. Dynamic muscle stimulation, with a specific regimen, may be beneficial to future orthopedic research in developing a countermeasure for disuse osteopenia and osteoporosis.
Collapse
Affiliation(s)
- Hoyan Lam
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-2580
| | - Yi-Xian Qin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-2580
| |
Collapse
|
15
|
Garman R, Gaudette G, Donahue LR, Rubin C, Judex S. Low-level accelerations applied in the absence of weight bearing can enhance trabecular bone formation. J Orthop Res 2007; 25:732-40. [PMID: 17318899 DOI: 10.1002/jor.20354] [Citation(s) in RCA: 111] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
High-frequency whole body vibrations can be osteogenic, but their efficacy appears limited to skeletal segments that are weight bearing and thus subject to the induced load. To determine the anabolic component of this signal, we investigated whether low-level oscillatory displacements, in the absence of weight bearing, are anabolic to skeletal tissue. A loading apparatus, developed to shake specific segments of the murine skeleton without the direct application of deformations to the tissue, was used to subject the left tibia of eight anesthesized adult female C57BL/6J mice to small (0.3 g or 0.6 g) 45 Hz sinusoidal accelerations for 10 min/day, while the right tibia served as an internal control. Video and strain analysis revealed that motions of the apparatus and tibia were well coupled, inducing dynamic cortical deformations of less than three microstrain. After 3 weeks, trabecular metaphyseal bone formation rates and the percentage of mineralizing surfaces (MS/BS) were 88% and 64% greater (p < 0.05) in tibiae accelerated at 0.3 g than in their contralateral controls. At 0.6 g, bone formation rates and mineral apposition rates were 66% and 22% greater (p < 0.05) in accelerated tibiae. Changes in bone morphology were evident only in the epiphysis, where stimulated tibiae displayed significantly greater cortical area (+8%) and thickness (+8%). These results suggest that tiny acceleratory motions--independent of direct loading of the matrix--can influence bone formation and bone morphology. If confirmed by clinical studies, the unique nature of the signal may ultimately facilitate the stimulation of skeletal regions that are prone to osteoporosis even in patients that are suffering from confinement to wheelchairs, bed rest, or space travel.
Collapse
Affiliation(s)
- Russell Garman
- Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY 11794-2580, USA
| | | | | | | | | |
Collapse
|
16
|
Bacabac RG, Smit TH, Van Loon JJWA, Doulabi BZ, Helder M, Klein-Nulend J. Bone cell responses to high-frequency vibration stress: does the nucleus oscillate within the cytoplasm? FASEB J 2006; 20:858-64. [PMID: 16675843 DOI: 10.1096/fj.05-4966.com] [Citation(s) in RCA: 87] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Mechanosensing by cells directs changes in bone mass and structure in response to the challenges of mechanical loading. Low-amplitude, high-frequency loading stimulates bone growth by enhancing bone formation and inhibiting disuse osteoporosis. However, how bone cells sense vibration stress is unknown. Hence, we investigated bone cell responses to vibration stress at a wide frequency range (5-100 Hz). We used NO and prostaglandin E2 (PGE2) release, and COX-2 mRNA expression as parameters for bone cell response since these molecules regulate bone adaptation to mechanical loading. NO release positively correlated whereas PGE2 release negatively correlated to the maximum acceleration rate of the vibration stress. COX-2 mRNA expression increased in a frequency-dependent manner, which relates to increased NO release at high frequencies, confirming our previous results. The negatively correlated release of NO and PGE2 suggests that these signaling molecules play different roles in bone adaptation to high-frequency loading. The maximum acceleration rate is proportional to omega3 (frequency=omega/2pi), which is commensurate with the Stokes-Einstein relation for modeling cell nucleus motion within the cytoplasm due to vibration stress. Correlations of NO and PGE2 with the maximum acceleration rate then relate to nucleus oscillations, providing a physical basis for cellular mechanosensing of high-frequency loading.
Collapse
Affiliation(s)
- Rommel G Bacabac
- Department of Oral Cell Biology, Academic Centre for Dentistry Amsterdam--Universiteit van Amsterdam, Amsterdam, The Netherlands
| | | | | | | | | | | |
Collapse
|