Assessing the viability of Legionella pneumophila in environmental samples: regarding the filter application of Ethidium Monoazide Bromide. ANN MICROBIOL 2021. [DOI: 10.1186/s13213-021-01653-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Purpose
Analyses of 34 water samples from 13 healthcare structures revealed how culture method and quantitative PCR (qPCR) often differ in the detection of Legionella pneumophila (Lp). With these considerations in hand, culture method, PCR and Ethidium Monoazide Bromide (EMA) qPCR have all been compared in order to detect Lp in water samples, identify a method able to speed up the procedures, detect the “viable but not cultivable” bacteria (VBNC) and exclude non-viable bacteria using a commercial kit for extraction and amplification as well as modification of the protocol.
Methods
Pure water samples artificially spiked with viable, non-viable and VBNC Lp ATCC 33152 were analyzed using a commercial kit for both qPCR and EMA-qPCR, while ISO 11731-2-2004 was used for culture method.
Results
Only 35% (12/34) of the environmental samples were positive in both culture and qPCR methods. With regard to EMA-qPCR, results showed the absence of dye toxicity on viable and VBNC strains and an incomplete effectiveness on the non-viable ones. In both viable and VBNC strains, a decrease of bacterial DNA amplification was recorded as a function of sample dilution but not of EMA concentration.
Conclusions
Discrepancies between culture method and EMA-qPCR were observed and may be due to different causes such as membrane-dye interactions, presence of interfering compounds and the sensitivity of the kit used.
Study significance and impact
In the presence of one or more suspected cases of nosocomial legionellosis, the application of a rapid molecular method able to identify only the viable and VBNC Lp would be useful in order to quickly identify the source of infection and to intervene with sanitation treatments. However, seeing that in our experience EMA pretreatment on the filter membrane did not come up with the expected results, it would be necessary to proceed with other experiments and/or different dyes.
Graphical Abstract
Collapse
|
2
|
Investigation of the effects of various stress factors on biofilms and planktonic bacteria in cooling tower model system. Arch Microbiol 2021; 203:1411-1425. [PMID: 33388788 DOI: 10.1007/s00203-020-02116-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 09/09/2020] [Accepted: 11/08/2020] [Indexed: 11/27/2022]
Abstract
Biofilm is a microbial population which live in a self-produced extracellular polymeric matrix by attaching to surfaces. Biofilms consist of different different types of organisms such as bacteria, fungi, protozoa, etc. Many biofilms that develop in nature consist of more than one type of organism. Biofilms protect bacteria from adverse conditions such as temperature fluctuation and disinfectants. The aim of this study was to determine the effective elimination strategies for combating biofilm and planktonic bacteria in cooling tower model system using different decontamination / disinfection techniques. In this study, 14 week-old biofilms were treated with temperatures of 4 °C, 65 °C; pH of 3, 11; 2 and 10 mg/l chlorine, 2 and 10 mg/l monochloramine; hypotonic salt (0.01% NaCl) and hypertonic salt (3% NaCl) solution. For enumeration, number of aerobic heterotrophic bacteria was determined by conventional culture method, number of live bacteria was determined by LIVE/DEAD viability kit, CTC-DAPI and Alamar blue staining methods. Temperature of 65 °C, pH of 3, 10 mg/l monochloramine and hypertonic salt solution were the most effective parameters for decontamination of biofilm and planktonic bacteria. Biofilm bacteria in the circulating water system were significantly more resistant than planktonic bacteria against stress factors. When the numbers of epifluorescence microscopy and conventional culture technique were compared, significantly higher number of live bacteria were detected using epifluorescence microscopy. Bacteria enter the viable but non-culturable phase by loosing their culturability under stress conditions. For this reason, the conventional culture method should be supported by different techniques to get more realistic numbers.
Collapse
|
3
|
Molecular detection of opportunistic pathogens and insights into microbial diversity in private well water and premise plumbing. JOURNAL OF WATER AND HEALTH 2020; 18:820-834. [PMID: 33095203 PMCID: PMC9115838 DOI: 10.2166/wh.2020.271] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Private well water systems in rural areas that are improperly maintained will result in poor drinking water quality, loss of water supply, and pose human health risk. The purpose of this study was to investigate the occurrence of fecal indicator bacteria (FIB) and opportunistic pathogens in private well water in rural areas surrounding New Orleans, Louisiana. Our results confirmed the ubiquitous nature of Legionella (86.7%) and mycobacteria (68.1%) in private well water in the study area, with gene concentration ranged from 0.60 to 5.53 and 0.67 to 5.95 Log10 of GC/100 mL, respectively. Naegleria fowleri target sequence was detected in 16.8% and Escherichia coli was detected in 43.4% of the water samples. Total coliform, as well as Legionella and mycobacteria genetic markers' concentrations were significantly reduced by 3-minute flushing. Next-generation sequencing (NGS) data indicated that the abundance of bacterial species was significantly increased in water collected in kitchens compared with samples from wells directly. This study provided integrated knowledge on the persistence of pathogenic organisms in private well water. Further study is needed to explore the presence of clinical species of those opportunistic pathogens in private well water systems to elucidate the health risk.
Collapse
|
4
|
Quantitative Microbial Risk Assessment and Molecular Biology: Paths to Integration. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:8539-8546. [PMID: 32539352 DOI: 10.1021/acs.est.0c00664] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Quantitative microbial risk assessment (QMRA) has now been in use for over 35 years and has formed the basis for developing criteria for ensuring public health related to water, food, and remediation, to name a few areas. The initial data for QMRA (both in exposure assessment and in dose response assessment) came from measurements using assays for viability, such as plate counts, plaque assays, or animal infectivity. With the increasing use of molecular methods for the measurement of microorganisms in the environment, it has become important to assess how to use such data to estimate infectious disease risks. The limitations to the use of such data and needs to resolve the limitations will be addressed.
Collapse
|
5
|
Validation of large-volume batch solar reactors for the treatment of rainwater in field trials in sub-Saharan Africa. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 717:137223. [PMID: 32062239 DOI: 10.1016/j.scitotenv.2020.137223] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 01/24/2020] [Accepted: 02/07/2020] [Indexed: 06/10/2023]
Abstract
The efficiency of two large-volume batch solar reactors [Prototype I (140 L) and II (88 L)] in treating rainwater on-site in a local informal settlement and farming community was assessed. Untreated [Tank 1 and Tank 2-(First-flush)] and treated (Prototype I and II) tank water samples were routinely collected from each site and all the measured physico-chemical parameters (e.g. pH and turbidity, amongst others), anions (e.g. sulphate and chloride, amongst others) and cations (e.g. iron and lead, amongst others) were within national and international drinking water guidelines limits. Culture-based analysis indicated that Escherichia coli, total and faecal coliforms, enterococci and heterotrophic bacteria counts exceeded drinking water guideline limits in 61%, 100%, 45%, 24% and 100% of the untreated tank water samples collected from both sites. However, an 8 hour solar exposure treatment for both solar reactors was sufficient to reduce these indicator organisms to within national and international drinking water standards, with the exception of the heterotrophic bacteria which exceeded the drinking water standard limit in 43% of the samples treated with the Prototype I reactor (1 log reduction). Molecular viability analysis subsequently indicated that mean overall reductions of 75% and 74% were obtained for the analysed indicator organisms (E. coli and enterococci spp.) and opportunistic pathogens (Klebsiella spp., Legionella spp., Pseudomonas spp., Salmonella spp. and Cryptosporidium spp. oocysts) in the Prototype I and II solar reactors, respectively. The large-volume batch solar reactor prototypes could thus effectively provide four (88 L Prototype II) to seven (144 L Prototype I) people on a daily basis with the basic water requirement for human activities (20 L). Additionally, a generic Water Safety Plan was developed to aid practitioners in identifying risks and implement remedial actions in this type of installation in order to ensure the safety of the treated water.
Collapse
|
6
|
Characterizing the effects of thermal treatment on human norovirus GII.4 viability using propidium monoazide combined with RT-qPCR and quality assessments in mussels. Food Control 2020. [DOI: 10.1016/j.foodcont.2019.106954] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
7
|
Microbiological Assessment of Tap Water Following the 2016 Louisiana Flooding. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17041273. [PMID: 32079198 PMCID: PMC7068305 DOI: 10.3390/ijerph17041273] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 02/05/2020] [Accepted: 02/09/2020] [Indexed: 11/17/2022]
Abstract
Floods are a prominent risk factor in the world of public health, as there is a risk of dispersal of harmful biological and chemical contaminants in floodwater. As climate change increases, the occurrence of natural disasters and risk of adverse health outcomes due to flash flooding also increases. Fecal indicator bacteria, such as Escherichia coli and Enterococci, are often encountered in contaminated floodwater and can cause gastrointestinal illnesses as well as a variety of infections. In August 2016, East Baton Rouge and surrounding parishes in Louisiana suffered heavy floods due to intense rainfall. No study of water quality during flooding has been conducted previously in Baton Rouge, Louisiana. Twenty-three pre-flush and post-flush water samples were collected immediately from accessible homes that had been affected by the floods in order to quantify concentrations of fecal indicator bacteria. These samples were analyzed for the presence of E. coli and Enterococci through both quantitative polymerase chain reaction (qPCR) and the IDEXX enzyme substrate method. The qPCR results indicated that 30% of the samples contained Enterococci and 61% of the samples contained E. coli, with the highest concentrations found in the pre-flush outdoor hose and the pre-flush kitchen tap. The IDEXX method yielded total coliforms in 65% of the samples, E. coli in 4%, and Enterococci in 35%, with the highest concentrations in the pre-flush outdoor faucet and the pre-flush post-filtration kitchen tap. Physical parameters including temperature, barometer pressure, dissolved oxygen, oxidation reduction potential, pH, conductivity, and salinity of these samples were also recorded. Of these parameters, conductivity and salinity were significant, suggesting they may positively influence E. coli and Enterococci growth.
Collapse
|
8
|
The relevance of molecular genotyping to allocate cases in a suspected outbreak of Legionella pneumonia in patients with prolonged immunosuppressive therapy. Int J Infect Dis 2019; 91:174-176. [PMID: 31707135 DOI: 10.1016/j.ijid.2019.11.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 10/31/2019] [Accepted: 11/01/2019] [Indexed: 10/25/2022] Open
Abstract
Three cases of pneumonia caused by Legionella pneumophila serogroup 1 (Lp1) in immunosuppressed patients with repeated hospitalization were suspected as a healthcare-associated cluster. The environmental investigation did not reveal the presence of legionellae in the hospital patient rooms. Water samples collected from the homes of two patients were also negative for Legionella spp. In the absence of environmental strains potentially involved in the infections, we proceeded to genotype environmental Lp1 strains isolated in the hospital during routine water sampling during the decade 2009-2019 and recovered after long-term storage at -20°C. These 'historical' strains exhibited a high grade of similarity and stability over time, regardless of the disinfection systems. The different molecular profiles shown among the clinical and environmental strains excluded a nosocomial outbreak. The study suggests that the application of molecular typing may be a useful tool to discriminate hospital vs community-acquired cases, mostly for severely immunosuppressed patients in whom the symptomatology could be insidious and the incubation period could be prolonged. Moreover, the genotyping allowed us to exclude any link between the cases.
Collapse
|
9
|
Occurrence of culturable
Legionella pneumophila
in drinking water distribution systems. ACTA ACUST UNITED AC 2019. [DOI: 10.1002/aws2.1139] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
10
|
Risk-Based Critical Concentrations of Legionella pneumophila for Indoor Residential Water Uses. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:4528-4541. [PMID: 30629886 DOI: 10.1021/acs.est.8b03000] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Legionella spp. is a key contributor to the United States waterborne disease burden. Despite potentially widespread exposure, human disease is relatively uncommon, except under circumstances where pathogen concentrations are high, host immunity is low, or exposure to small-diameter aerosols occurs. Water quality guidance values for Legionella are available for building managers but are generally not based on technical criteria. To address this gap, a quantitative microbial risk assessment (QMRA) was conducted using target risk values in order to calculate corresponding critical concentrations on a per-fixture and aggregate (multiple fixture exposure) basis. Showers were the driving indoor exposure risk compared to sinks and toilets. Critical concentrations depended on the dose response model (infection vs clinical severity infection, CSI), risk target used (infection risk vs disability adjusted life years [DALY] on a per-exposure or annual basis), and fixture type (conventional vs water efficient or "green"). Median critical concentrations based on exposure to a combination of toilet, faucet, and shower aerosols ranged from ∼10-2 to ∼100 CFU per L and ∼101 to ∼103 CFU per L for infection and CSI dose response models, respectively. As infection model results for critical L. pneumophila concentrations were often below a feasible detection limit for culture-based assays, the use of CSI model results for nonhealthcare water systems with a 10-6 DALY pppy target (the more conservative target) would result in an estimate of 12.3 CFU per L (arithmetic mean of samples across multiple fixtures and/or over time). Single sample critical concentrations with a per-exposure-corrected DALY target at each conventional fixture would be 1.06 × 103 CFU per L (faucets), 8.84 × 103 CFU per L (toilets), and 14.4 CFU per L (showers). Using a 10-4 annual infection risk target would give a 1.20 × 103 CFU per L mean for multiple fixtures and single sample critical concentrations of 1.02 × 105, 8.59 × 105, and 1.40 × 103 CFU per L for faucets, toilets, and showers, respectively. Annual infection risk-based target estimates are in line with most current guidance documents of less than 1000 CFU per L, while DALY-based guidance suggests lower critical concentrations might be warranted in some cases. Furthermore, approximately <10 CFU per mL L. pneumophila may be appropriate for healthcare or susceptible population settings. This analysis underscores the importance of the choice of risk target as well as sampling program considerations when choosing the most appropriate critical concentration for use in public health guidance.
Collapse
|
11
|
Legionella occurrence in municipal and industrial wastewater treatment plants and risks of reclaimed wastewater reuse: Review. WATER RESEARCH 2019; 149:21-34. [PMID: 30445393 DOI: 10.1016/j.watres.2018.10.080] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 10/26/2018] [Accepted: 10/27/2018] [Indexed: 05/22/2023]
Abstract
Wastewater treatment plants (WWTPs) have been identified as confirmed but until today underestimated sources of Legionella, playing an important role in local and community cases and outbreaks of Legionnaires' disease. In general, aerobic biological systems provide an optimum environment for the growth of Legionella due to high organic nitrogen and oxygen concentrations, ideal temperatures and the presence of protozoa. However, few studies have investigated the occurrence of Legionella in WWTPs, and many questions in regards to the interacting factors that promote the proliferation and persistence of Legionella in these treatment systems are still unanswered. This critical review summarizes the current knowledge about Legionella in municipal and industrial WWTPs, the conditions that might support their growth, as well as control strategies that have been applied. Furthermore, an overview of current quantification methods, guidelines and health risks associated with Legionella in reclaimed wastewater is also discussed in depth. A better understanding of the conditions promoting the occurrence of Legionella in WWTPs will contribute to the development of improved wastewater treatment technologies and/or innovative mitigation approaches to minimize future Legionella outbreaks.
Collapse
|
12
|
Effectiveness of a neutral electrolysed oxidising water (NEOW) device in reducing Legionella pneumophila in a water distribution system: A comparison between culture, qPCR and PMA-qPCR detection methods. CHEMOSPHERE 2018; 210:550-556. [PMID: 30029147 DOI: 10.1016/j.chemosphere.2018.07.053] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 07/09/2018] [Accepted: 07/10/2018] [Indexed: 05/22/2023]
Abstract
Disinfection of hot water systems is critical for reducing Legionnaires' disease in high-risk buildings. The use of neutral electrolysed oxidising water (NEOW) is a promising method for the control of microorganisms in hot water systems. However, full-scale evaluations of the efficacy of NEOW devices to control Legionella pneumophila are currently lacking. The aim of this study was to assess the effectiveness of a NEOW device in reducing L. pneumophila in a hotel water network. Water samples (n = 67) were collected from different sites of a hotel distribution system before and after the installation of the NEOW device at the 1st, 4th, 8th and 12th week. Detection of L. pneumophila was performed comparing culture, qPCR and PMA-qPCR methods. Total bacterial counts (22 °C and 37 °C), Pseudomonas spp. and physico-chemical parameters were also monitored. The NEOW treatment resulted in a reduction of the amount of L. pneumophila positive samples (-32%) and of the number of heavily contaminated points (>104 CFU/L and >103 CFU/L) (-100% and -96%, respectively). Treatment maintained L. pneumophila at low levels (<102 CFU/L), which do not require specific intervention measures. The effectiveness of the disinfection system was also confirmed by PMA-qPCR (p < 0.001). The use of PMA resulted in a signal decrease in almost all samples upon the disinfection treatment. The NEOW disinfection device appears to be a promising approach to reduce the colonisation of hot water systems by L. pneumophila; however, further investigations are needed to ascertain its efficiency over longer time periods.
Collapse
|
13
|
Enumeration of Vibrio parahaemolyticus in VBNC state by PMA-combined real-time quantitative PCR coupled with confirmation of respiratory activity. Food Control 2018. [DOI: 10.1016/j.foodcont.2018.03.037] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
14
|
Sinks and sources of anammox bacteria in a wastewater treatment plant - screening with qPCR. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2018; 78:441-451. [PMID: 30101779 DOI: 10.2166/wst.2018.318] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The deammonification process, which includes nitritation and anammox bacteria, is an energy-efficient nitrogen removal process. Starting up an anammox process in a wastewater treatment plant (WWTP) is still widely believed to require external seeding of anammox bacteria. To demonstrate the principle of a non-seeded anammox start-up, anammox bacteria in potential sources must be quantified. In this study, seven digesters, their substrates and reject water were sampled and quantitative polymerase chain reaction (qPCR) was used to quantify both total and viable anammox bacteria. The results show that mesophilic digesters fed with nitrifying sludge (with high sludge ages) can be classified as a reliable source of anammox bacteria. Sludge hygienization and dewatering of digestate reduce the amount of anammox bacteria by one to two orders of magnitude and can be considered as a sink. The sampled reject waters contained on average >4.0 × 104 copies mL-1 and the majority of these cells (>87%) were viable cells. Furthermore, plants with side-stream anammox treatment appear to have higher overall quantities of anammox bacteria than those without such treatment. The present study contributes to the development of sustainable strategies for both start-up of anammox reactors and the possibility of improving microbial management in WWTPs.
Collapse
|
15
|
Occurrence of Legionella spp. in Water-Main Biofilms from Two Drinking Water Distribution Systems. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:7630-7639. [PMID: 29902377 DOI: 10.1021/acs.est.8b01170] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The maintenance of a chlorine or chloramine residual to suppress waterborne pathogens in drinking water distribution systems is common practice in the United States but less common in Europe. In this study, we investigated the occurrence of Bacteria and Legionella spp. in water-main biofilms and tap water from a chloraminated distribution system in the United States and a system in Norway with no residual using real-time quantitative polymerase chain reaction (qPCR). Despite generally higher temperatures and assimilable organic carbon levels in the chloraminated system, total Bacteria and Legionella spp. were significantly lower in water-main biofilms and tap water of that system ( p < 0.05). Legionella spp. were not detected in the biofilms of the chloraminated system (0 of 35 samples) but were frequently detected in biofilms from the no-residual system (10 of 23 samples; maximum concentration = 7.8 × 104 gene copies cm-2). This investigation suggests water-main biofilms may serve as a source of Legionella for tap water and premise plumbing systems, and residual chloramine may aid in reducing their abundance.
Collapse
|
16
|
Health risks from exposure to Legionella in reclaimed water aerosols: Toilet flushing, spray irrigation, and cooling towers. WATER RESEARCH 2018; 134:261-279. [PMID: 29428779 DOI: 10.1016/j.watres.2017.12.022] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Revised: 11/30/2017] [Accepted: 12/12/2017] [Indexed: 05/05/2023]
Abstract
The use of reclaimed water brings new challenges for the water industry in terms of maintaining water quality while increasing sustainability. Increased attention has been devoted to opportunistic pathogens, especially Legionella pneumophila, due to its growing importance as a portion of the waterborne disease burden in the United States. Infection occurs when a person inhales a mist containing Legionella bacteria. The top three uses for reclaimed water (cooling towers, spray irrigation, and toilet flushing) that generate aerosols were evaluated for Legionella health risks in reclaimed water using quantitative microbial risk assessment (QMRA). Risks are compared using data from nineteen United States reclaimed water utilities measured with culture-based methods, quantitative PCR (qPCR), and ethidium-monoazide-qPCR. Median toilet flushing annual infection risks exceeded 10-4 considering multiple toilet types, while median clinical severity infection risks did not exceed this value. Sprinkler and cooling tower risks varied depending on meteorological conditions and operational characteristics such as drift eliminator performance. However, the greatest differences between risk scenarios were due to 1) the dose response model used (infection or clinical severity infection) 2) population at risk considered (residential or occupational) and 3) differences in laboratory analytical method. Theoretical setback distances necessary to achieve a median annual infection risk level of 10-4 are proposed for spray irrigation and cooling towers. In both cooling tower and sprinkler cases, Legionella infection risks were non-trivial at potentially large setback distances, and indicate other simultaneous management practices could be needed to manage risks. The sensitivity analysis indicated that the most influential factors for variability in risks were the concentration of Legionella and aerosol partitioning and/or efficiency across all models, highlighting the importance of strategies to manage Legionella occurrence in reclaimed water.
Collapse
|
17
|
Potential testing of reprocessing procedures by real-time polymerase chain reaction: A multicenter study of colonoscopy devices. Am J Infect Control 2018; 46:159-164. [PMID: 28958445 DOI: 10.1016/j.ajic.2017.08.008] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Revised: 08/07/2017] [Accepted: 08/08/2017] [Indexed: 12/27/2022]
Abstract
BACKGROUND Reprocessing of endoscopes is key to preventing cross-infection after colonoscopy. Culture-based methods are recommended for monitoring, but alternative and rapid approaches are needed to improve surveillance and reduce turnover times. A molecular strategy based on detection of residual traces from gut microbiota was developed and tested using a multicenter survey. METHODS A simplified sampling and DNA extraction protocol using nylon-tipped flocked swabs was optimized. A multiplex real-time polymerase chain reaction (PCR) test was developed that targeted 6 bacteria genes that were amplified in 3 mixes. The method was validated by interlaboratory tests involving 5 reference laboratories. Colonoscopy devices (n = 111) were sampled in 10 Italian hospitals. Culture-based microbiology and metagenomic tests were performed to verify PCR data. RESULTS The sampling method was easily applied in all 10 endoscopy units and the optimized DNA extraction and amplification protocol was successfully performed by all of the involved laboratories. This PCR-based method allowed identification of both contaminated (n = 59) and fully reprocessed endoscopes (n = 52) with high sensibility (98%) and specificity (98%), within 3-4 hours, in contrast to the 24-72 hours needed for a classic microbiology test. Results were confirmed by next-generation sequencing and classic microbiology. CONCLUSIONS A novel approach for monitoring reprocessing of colonoscopy devices was developed and successfully applied in a multicenter survey. The general principle of tracing biological fluids through microflora DNA amplification was successfully applied and may represent a promising approach for hospital hygiene.
Collapse
|
18
|
Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment. BUILDING AND ENVIRONMENT 2017; 123:684-695. [PMID: 29104349 PMCID: PMC5665586 DOI: 10.1016/j.buildenv.2017.06.024] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Legionella is a genus of pathogenic Gram-negative bacteria responsible for a serious disease known as legionellosis, which is transmitted via inhalation of this pathogen in aerosol form. There are two forms of legionellosis: Legionnaires' disease, which causes pneumonia-like symptoms, and Pontiac fever, which causes influenza-like symptoms. Legionella can be aerosolized from various water sources in the built environment including showers, faucets, hot tubs/swimming pools, cooling towers, and fountains. Incidence of the disease is higher in the summertime, possibly because of increased use of cooling towers for air conditioning systems and differences in water chemistry when outdoor temperatures are higher. Although there have been decades of research related to Legionella transmission, many knowledge gaps remain. While conventional wisdom suggests that showering is an important source of exposure in buildings, existing measurements do not provide strong support for this idea. There has been limited research on the potential for Legionella transmission through heating, ventilation, and air conditioning (HVAC) systems. Epidemiological data suggest a large proportion of legionellosis cases go unreported, as most people who are infected do not seek medical attention. Additionally, controlled laboratory studies examining water-to-air transfer and source tracking are still needed. Herein, we discuss ten questions that spotlight current knowledge about Legionella transmission in the built environment, engineering controls that might prevent future disease outbreaks, and future research that is needed to advance understanding of transmission and control of legionellosis.
Collapse
|
19
|
Detection of viable but non-culturable legionella in hospital water network following monochloramine disinfection. J Hosp Infect 2017; 98:46-52. [PMID: 28917570 DOI: 10.1016/j.jhin.2017.09.006] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Revised: 09/04/2017] [Accepted: 09/07/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND Prevention of legionellosis remains a critical issue in healthcare settings where monochloramine (MC) disinfection was recently introduced as an alternative to chlorine dioxide in controlling Legionella spp. contamination of the hospital water network. Continuous treatments with low MC doses in some instances have induced a viable but non-culturable state (VBNC) of Legionella spp. AIM To investigate the occurrence of such dormant cells during a long period of continuous MC treatment. METHODS Between November 2010 and April 2015, 162 water and biofilm samples were collected and Legionella spp. isolated in accordance with standard procedures. In sampling sites where MC was <1.5mg/L, VBNC cells were investigated by ethidium monoazide bromide (EMA)-real-time polymerase chain reaction (qPCR) and 'resuscitation' test into Acanthamoeba polyphaga CCAP 1501/18. According to the Health Protection Agency protocol, free-living protozoa were researched in 60 five-litre water samples. FINDINGS In all, 136 out of 156 (87.2%) of the samples taken from sites previously positive for L. pneumophila ST269 were negative by culture, but only 47 (34.5%) negative by qPCR. Although no positive results were obtained by EMA-qPCR, four out of 22 samples associated with MC concentration of 1.3 ± 0.5mg/L showed VBNC legionella resuscitation. The presence of the amoeba A. polyphaga in the hospital water network was demonstrated. CONCLUSION Our study is the first report evidencing the emergence of VNBC legionella during a long period of continuous MC treatment of a hospital water network, highlighting the importance of keeping an appropriate and uninterrupted MC dosage to ensure the control of legionella colonization in hospital water supplies.
Collapse
|
20
|
Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2017. [PMID: 28640202 PMCID: PMC5551108 DOI: 10.3390/ijerph14070670] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.
Collapse
|
21
|
Methodological approaches for monitoring opportunistic pathogens in premise plumbing: A review. WATER RESEARCH 2017; 117:68-86. [PMID: 28390237 PMCID: PMC5693313 DOI: 10.1016/j.watres.2017.03.046] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Revised: 03/19/2017] [Accepted: 03/22/2017] [Indexed: 05/06/2023]
Abstract
Opportunistic premise (i.e., building) plumbing pathogens (OPPPs, e.g., Legionella pneumophila, Mycobacterium avium complex, Pseudomonas aeruginosa, Acanthamoeba, and Naegleria fowleri) are a significant and growing source of disease. Because OPPPs establish and grow as part of the native drinking water microbiota, they do not correspond to fecal indicators, presenting a major challenge to standard drinking water monitoring practices. Further, different OPPPs present distinct requirements for sampling, preservation, and analysis, creating an impediment to their parallel detection. The aim of this critical review is to evaluate the state of the science of monitoring OPPPs and identify a path forward for their parallel detection and quantification in a manner commensurate with the need for reliable data that is informative to risk assessment and mitigation. Water and biofilm sampling procedures, as well as factors influencing sample representativeness and detection sensitivity, are critically evaluated with respect to the five representative bacterial and amoebal OPPPs noted above. Available culturing and molecular approaches are discussed in terms of their advantages, limitations, and applicability. Knowledge gaps and research needs towards standardized approaches are identified.
Collapse
|
22
|
Viability of Legionella pneumophila in Water Samples: A Comparison of Propidium Monoazide (PMA) Treatment on Membrane Filters and in Liquid. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2017; 14:ijerph14050467. [PMID: 28448459 PMCID: PMC5451918 DOI: 10.3390/ijerph14050467] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2017] [Revised: 04/18/2017] [Accepted: 04/20/2017] [Indexed: 11/16/2022]
Abstract
Legionella pneumophila is a ubiquitous microorganism widely distributed in aquatic environments and can cause Legionellosis in humans. A promising approach to detect viable cells in water samples involves the use of quantitative polymerase chain reaction (qPCR) in combination with photoactivatable DNA intercalator propidium monoazide (PMA). However, the PMA efficiency could be different depending on the experimental conditions used. The aim of this study was to compare two PMA exposure protocols: (A) directly on the membrane filter or (B) in liquid after filter washing. The overall PMA-induced qPCR means reductions in heat-killed L. pneumophila cells were 2.42 and 1.91 log units for exposure protocols A and B, respectively. A comparison between the results obtained reveals that filter exposure allows a higher PMA-qPCR signal reduction to be reached, mainly at low concentrations (p < 0.05). This confirms the potential use of this method to quantify L. pneumophila in water with low contamination.
Collapse
|
23
|
Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures. Appl Environ Microbiol 2016; 82:2959-2965. [PMID: 26969696 DOI: 10.1128/aem.03873-15] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Accepted: 03/03/2016] [Indexed: 12/13/2022] Open
Abstract
Physical and chemical disinfection methods have been proposed with the aim of controlling Legionella water contamination. To date, the most effective procedures for reducing bacterial contamination have not yet been defined. The aim of this study was to assess the long-term effectiveness of various disinfection procedures in order to reduce both culturable and nonculturable (NC) legionellae in different hospital water networks treated with heat, chlorine dioxide, monochloramine, and hydrogen peroxide. The temperature levels and biocide concentrations that proved to give reliable results were analyzed. In order to study the possible effects on the water pipes, we verified the extent of corrosion on experimental coupons after applying each method for 6 months. The percentage of positive points was at its lowest after treatment with monochloramine, followed by chlorine dioxide, hydrogen peroxide, and hyperthermia. Different selections of Legionella spp. were observed, as networks treated with chlorine-based disinfectants were contaminated mainly by Legionella pneumophila serogroup 1, hyperthermia was associated with serogroups 2 to 14, and hydrogen peroxide treatment was associated mainly with non-pneumophila species. NC cells were detected only in heat-treated waters, and also when the temperature was approximately 60°C. The corrosion rates of the coupons were within a satisfactory limit for water networks, but the morphologies differed. We confirm here that chemical disinfection controls Legionella colonization more effectively than hyperthermia does. Monochloramine was the most effective treatment, while hydrogen peroxide may be a promising alternative to chlorine-based disinfectants due to its ability to select for other, less virulent or nonpathogenic species.
Collapse
|
24
|
Temperature diagnostic to identify high risk areas and optimize Legionella pneumophila surveillance in hot water distribution systems. WATER RESEARCH 2015; 71:244-56. [PMID: 25622002 DOI: 10.1016/j.watres.2015.01.006] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2014] [Revised: 12/22/2014] [Accepted: 01/05/2015] [Indexed: 05/08/2023]
Abstract
Legionella pneumophila is frequently detected in hot water distribution systems and thermal control is a common measure implemented by health care facilities. A risk assessment based on water temperature profiling and temperature distribution within the network is proposed, to guide effective monitoring strategies and allow the identification of high risk areas. Temperature and heat loss at control points (water heater, recirculation, representative points-of-use) were monitored in various sections of five health care facilities hot water distribution systems and results used to develop a temperature-based risk assessment tool. Detailed investigations show that defective return valves in faucets can cause widespread temperature losses because of hot and cold water mixing. Systems in which water temperature coming out of the water heaters was kept consistently above 60 °C and maintained above 55 °C across the network were negative for Legionella by culture or qPCR. For systems not meeting these temperature criteria, risk areas for L. pneumophila were identified using temperature profiling and system's characterization; higher risk was confirmed by more frequent microbiological detection by culture and qPCR. Results confirmed that maintaining sufficiently high temperatures within hot water distribution systems suppressed L. pneumophila culturability. However, the risk remains as shown by the persistence of L. pneumophila by qPCR.
Collapse
|