1
|
Hanifar K, Almajidi YQ, Sanaan Jabbar H, Alexis Ramírez-Coronel A, Altalbawy FMA, Almulla AF, Turki Jalil A, Awad SA, Andres Barboza-Arenas L. An Environmental-friendly Procedure Based on Deep Eutectic Solvent for Extraction and Determination of Toxic Elements in Fish Species from Different Regions of Iraq. J Food Prot 2023; 86:100102. [PMID: 37172905 DOI: 10.1016/j.jfp.2023.100102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 04/22/2023] [Accepted: 05/06/2023] [Indexed: 05/15/2023]
Abstract
In this study, an eco-friendly procedure was established by vortex-assisted liquid-phase microextraction based on deep eutectic solvent (VA-LPME-DES) combined with graphite furnace atomic absorption spectroscopy (GFAAS). The performance of this method was demonstrated by the extraction and analysis of lead (Pb), cadmium (Cd), and mercury (Hg) in fish samples. The hydrophobic DES is considered as a green extractant (environmentally friendly and less toxic than common organic solvents) and is a suitable alternative to common toxic organic solvents and is made of l-menthol and ethylene glycol (EG) with a molar ratio of 1:1. Under optimized conditions, the method linearity was in the ranges of 0.15-150 µg kg-1 with the coefficient of determinations (r2) higher than 0.996. Accordingly, the detection limits for Pb, Cd, and Hg were 0.05, 0.05, and 0.10 µg kg-1, respectively. The analysis of fish samples showed that the concentration of toxic elements in fish caught from the Tigris and Euphrates Rivers is much higher than the concentration of these elements in locally farmed trout fish. Also, the analysis of fish-certified reference materials with presented procedure produced results that were in good agreement with the certified values. The results showed that VA-LPME-DES is a very cheap, fast, and environmental-friendly procedure for the analysis of toxic elements in different types of fish species.
Collapse
Affiliation(s)
- Kalinaki Hanifar
- Department of Community Nutrition, Faculty of Human Ecology, Institut Pertanian Bogor, Bogor, Indonesia
| | - Yasir Q Almajidi
- Department of pharmaceutics, Baghdad College of Medical Sciences, Baghdad, Iraq
| | - Hijran Sanaan Jabbar
- Department of Chemistry, College of Science, Salahaddin University, Erbil, Kurdistan Region, Iraq; Department of Medical Laboratory Science, College of Health Sciences, Lebanese French University, Erbil, Kurdistan Region, Iraq.
| | | | - Farag M A Altalbawy
- National Institute of Laser Enhanced Sciences (NILES), University of Cairo, Giza 12613, Egypt; Department of Chemistry, University College of Duba, University of Tabuk, Tabuk, Saudi Arabia
| | - Abbas F Almulla
- Medical Laboratory Technology Department, College of Medical Technology, The Islamic University, Najaf, Iraq
| | - Abduladheem Turki Jalil
- Department of Medical Laboratories Techniques, Al-Mustaqbal University College, Babylon, Hilla 51001, Iraq
| | - Sameer A Awad
- Department of medical laboratory techniques, Al-Maarif University College, Al-Anbar-Ramadi 31001, Iraq
| | | |
Collapse
|
2
|
Amini MH, Beyki MH. Construction of 1, 10-phenanthroline functionalized magnetic starch as a lead (II) tagged surface imprinted biopolymer for highly selective targeting of toxic lead ions. Int J Biol Macromol 2023:124996. [PMID: 37236569 DOI: 10.1016/j.ijbiomac.2023.124996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/13/2023] [Accepted: 05/19/2023] [Indexed: 05/28/2023]
Abstract
In this research 1, 10 - phenanthroline functionalized CaFe2O4 - starch was employed as a magnetic ion-imprinted polymer (IIP) for highly selective targeting toxic Pb2+ ions from aqueous media. VSM analysis revealed that the sorbent has magnetic saturation of 10 emu g-1 which is appropriate for magnetic separation. Moreover, TEM analysis confirmed that the adsorbent is composed of particles with a mean diameter of 10 nm. According to XPS analysis, lead coordination with phenanthroline is the main adsorption mechanism that is along with electrostatic interaction. A maximum adsorption capacity of 120 mg g-1 was obtained within 10 min at a pH of 6 and an adsorbent dosage of 20 mg. Kinetic and isotherm studies showed that lead adsorption followed the pseudo-second-order and Freundlich models, respectively. The selectivity coefficient of Pb (II) relative to Cu(II), Co(II), Ni(II), Zn(II), Mn(II), and Cd(II) was 4.7, 14, 20, 36, 13 and 25, respectively. Moreover, the IIP represents the imprinting factor of 1.32. The sorbent showed good regeneration after five cycles of the sorption/desorption process with an efficiency of >93 %. Finally represented IIP was used for lead preconcentration from various matrices i.e., water, vegetable, and fish samples.
Collapse
Affiliation(s)
| | - Mostafa Hossein Beyki
- School of Chemistry, University College of Science, university of Tehran, Tehran, Iran
| |
Collapse
|
3
|
Karababa H, Atasoy M, Yildiz D, Kula İ, Tuzen M. Development of a Sensitive Method for Cadmium Determination in Fish Tissue and Drinking Water Samples by FAAS Using SQT In Situ Atom Trapping. ACS OMEGA 2023; 8:7063-7069. [PMID: 36844526 PMCID: PMC9947951 DOI: 10.1021/acsomega.2c07926] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 01/25/2023] [Indexed: 06/18/2023]
Abstract
A sensitive and robust trap method was developed for the determination of cadmium (Cd) by using a slotted quartz tube. Using this method at a sample suction rate of 7.4 mL/min for 4.0 min collection, a 1467-fold increase in sensitivity was obtained compared to the flame atomic absorption spectrometry method. Under the optimized conditions, a limit of detection of 0.075 ng mL-1 was obtained for the trap method. The interference effects of hydride-forming elements, transition metals, and some anions on the Cd signal were investigated. The developed method was evaluated by analyzing "Sewage Sludge-industrial origin (BCR no: 146R)", "NIST SRM 1640a Trace elements in natural water", and "DOLT: 5 Dogfish Liver". There was a good agreement between the certified and found values at the 95% confidence level. This method was applied successfully for the determination of Cd in drinking water and some fish tissue samples (liver, muscle, and gill) obtained from Muğla province.
Collapse
Affiliation(s)
- Hüseyin Karababa
- Department
of Chemistry, Muğla Sıtkı
Koçman University, Menteşe 48000 Muğla, Turkey
| | - Muhammet Atasoy
- Muğla
Vocational School, Chemistry and Chemical Treatment Technologies Department,
Chemistry Technology Program, Muğla
Sıtkı Koçman University, Menteşe 48000 Muğla, Turkey
| | - Dilek Yildiz
- Environmental
Problems Research and Application Center, Muğla Sıtkı Koçman University, Menteşe 48000 Muğla, Turkey
| | - İbrahim Kula
- Department
of Chemistry, Muğla Sıtkı
Koçman University, Menteşe 48000 Muğla, Turkey
| | - Mustafa Tuzen
- Faculty
of Arts and Sciences, Department of Chemistry, Tokat Gaziosmanpaşa University, 60250 Tokat, Turkey
| |
Collapse
|
4
|
Vallejos S, Trigo-López M, Arnaiz A, Miguel Á, Muñoz A, Mendía A, García JM. From Classical to Advanced Use of Polymers in Food and Beverage Applications. Polymers (Basel) 2022; 14:4954. [PMID: 36433081 PMCID: PMC9699061 DOI: 10.3390/polym14224954] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/11/2022] [Accepted: 11/14/2022] [Indexed: 11/18/2022] Open
Abstract
Polymers are extensively used in food and beverage packaging to shield against contaminants and external damage due to their barrier properties, protecting the goods inside and reducing waste. However, current trends in polymers for food, water, and beverage applications are moving forward into the design and preparation of advanced polymers, which can act as active packaging, bearing active ingredients in their formulation, or controlling the head-space composition to extend the shelf-life of the goods inside. In addition, polymers can serve as sensory polymers to detect and indicate the presence of target species, including contaminants of food quality indicators, or even to remove or separate target species for later quantification. Polymers are nowadays essential materials for both food safety and the extension of food shelf-life, which are key goals of the food industry, and the irruption of smart materials is opening new opportunities for going even further in these goals. This review describes the state of the art following the last 10 years of research within the field of food and beverage polymer's applications, covering present applications, perspectives, and concerns related to waste generation and the circular economy.
Collapse
Affiliation(s)
- Saúl Vallejos
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| | - Miriam Trigo-López
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| | - Ana Arnaiz
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
- Centro de Biotecnología y Genómica de Plantas, Instituto Nacional de Investigación y Tecnología Agraria y Alimentaria, Campus de Montegancedo, Universidad Politécnica de Madrid (UPM), 28223 Madrid, Spain
| | - Álvaro Miguel
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
- Facultad de Ciencias, Campus de Cantoblanco, Universidad Autónoma de Madrid, Calle Francisco Tomás y Valiente 7, 28049 Madrid, Spain
| | - Asunción Muñoz
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| | - Aránzazu Mendía
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| | - José Miguel García
- Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
| |
Collapse
|
5
|
Liu J, Chen M, Cui H. Synthesis of Ion-imprinted materials with amidoxime groups for enhanced UO22+ adsorption. Inorganica Chim Acta 2021. [DOI: 10.1016/j.ica.2020.120196] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
6
|
WANG X, CHEN Y, XIAO X, LI G. [Recent advances in sample preparation technologies for analysis of harmful substances in aquatic products]. Se Pu 2021; 39:34-45. [PMID: 34227357 PMCID: PMC9274841 DOI: 10.3724/sp.j.1123.2020.07025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Indexed: 11/25/2022] Open
Abstract
Aquatic products, which are among the most important sources of animal protein, contain proteins, vitamins, and a variety of trace elements, thus occupying an indispensable part of a reasonable diet. China is the largest consumer market of aquatic products in the world. The quality and safety of aquatic products are closely related not only to the healthy development of the aquaculture industry, but also to people's health. However, the presence of harmful substances has a bearing on the quality and safety of aquatic products in the overall process, including breeding, processing, storage, and transportation. These harmful substances are enriched in aquatic products and are transferred to humans via the food chain. Accurate determination of such harmful substances in aquatic product samples is imperative because of their complex matrices and extremely low concentrations. Many efficient sample preparation techniques such as liquid-liquid extraction, solid-phase extraction, and QuEChERS (quick, easy, cheap, effective, rugged, and safe method) with different configurations have been developed and widely employed for preconcentration in different matrices of aquatic products. Meanwhile, solid-phase microextraction has been demonstrated to be advantageous for some volatile and ultra-trace harmful substances. Suitable sample preparation techniques are important for effectively removing matrix interferences as well as for improving the sensitivity and accuracy of the method. It is important to develop appropriate sample preparation techniques for different target compounds in aquatic products. The harmful substances in aquatic products can be segregated into three categories according to their sources: (1) environmental pollutants in aquatic products; (2) substances acquired during aquaculture, transportation, and processing; (3) biotoxins in aquatic products. This article reviews the progress in sample pretreatment techniques for three harmful substances in aquatic products over the past decade. Various sample pretreatment techniques have been summarized and described, including liquid-liquid extraction, solid-phase extraction, solid-phase microextraction, QuEChERS, and magnetic solid-phase extraction. In addition, the merits and demerits of these techniques and future research directions are discussed. Finally, we reviewed the progress in functionalized materials for the preparation of aquatic product samples. With the increasing demand for aquatic products, quick, sensitive, and practical detection methods, such as surface-enhanced Raman scattering (SERS) are gaining importance. SERS has great potential for fast and accurate on-site detection of harmful substances in aquatic products. Several nondestructive sample pretreatment techniques have also been developed for harmful substances in aquatic products. The application and development of these techniques will guarantee the safety of aquatic products. Moreover, in vivo solid-phase microextraction is a potential method for aquatic product analysis. This technique integrates sampling, extraction, and enrichment into a single step, thus significantly reducing the processing time, labor, and cost. Overall, with the development and application of sophisticated materials and techniques, we can expect theoretical and practical advances in aquatic product analysis.
Collapse
|
7
|
Lai H, Li G, Zhang Z. Advanced materials on sample preparation for safety analysis of aquatic products. J Sep Sci 2020; 44:1174-1194. [DOI: 10.1002/jssc.202000955] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 10/06/2020] [Accepted: 10/07/2020] [Indexed: 12/23/2022]
Affiliation(s)
- Huasheng Lai
- School of Chemistry Sun Yat‐sen University Guangzhou P. R. China
| | - Gongke Li
- School of Chemistry Sun Yat‐sen University Guangzhou P. R. China
| | - Zhuomin Zhang
- School of Chemistry Sun Yat‐sen University Guangzhou P. R. China
| |
Collapse
|
8
|
Jagirani MS, Balouch A, Mahesar SA, Kumar A, Baloch AR, Abdullah., Bhanger MI. Fabrication of cadmium tagged novel ion imprinted polymer for detoxification of the toxic Cd2+ion from aqueous environment. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105247] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
9
|
Graphene oxide/Fe3O4/polyaniline nanocomposite as an efficient adsorbent for the extraction and preconcentration of ultra-trace levels of cadmium in rice and tea samples. RESEARCH ON CHEMICAL INTERMEDIATES 2020. [DOI: 10.1007/s11164-020-04256-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
10
|
de Oliveira LL, Suquila FA, de Figueiredo EC, Segatelli MG, Tarley CR. Restricted access material-ion imprinted polymer-based method for on-line flow preconcentration of Cd2+ prior to flame atomic absorption spectrometry determination. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
11
|
Jakavula S, Biata NR, Dimpe KM, Pakade VE, Nomngongo PN. A Critical Review on the Synthesis and Application of Ion-Imprinted Polymers for Selective Preconcentration, Speciation, Removal and Determination of Trace and Essential Metals from Different Matrices. Crit Rev Anal Chem 2020; 52:314-326. [PMID: 32723191 DOI: 10.1080/10408347.2020.1798210] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The presence of toxic trace metals and high concentrations of essential elements in the environment presents a serious threat to living organism. Various methods have been used for the detection, preconcentration and remediation of these metals from biological, environmental and food matrices. Owing to the complexicity of samples, methods with high selectivity have been used for detection, preconcentration and remediation of these trace metals. These methods are achieved by the use of ion-imprinted polymers (IIPs) due to their impressive properties such as selectivity, high extraction efficiency, speciation capability and reusability. Because of the increase of toxic trace and essential metals in the environment, IIPs have attracted great use in analytical chemistry. This review, provide a brief background on IIPs and polymerization method that are used for their preparation. Recent applications of IIPs as adsorbents for preconcentration, removal, speciation and electrochemical detection of trace and essential metal is also discussed.
Collapse
Affiliation(s)
- Silindokuhle Jakavula
- Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, Johannesburg, South Africa.,DSI/NRF SARChI Chair, Nanotechnology for Water, University of Johannesburg, Doornfontein, South Africa
| | - N Raphael Biata
- Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, Johannesburg, South Africa.,DSI/NRF SARChI Chair, Nanotechnology for Water, University of Johannesburg, Doornfontein, South Africa.,DSI/Mintek Nanotechnology Innovation Centre, University of Johannesburg, Doornfontein, South Africa
| | - K Mogolodi Dimpe
- Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, Johannesburg, South Africa
| | - Vusumzi E Pakade
- Department of Chemistry, Vaal University of Technology, Vanderbijlpark, South Africa
| | - Philiswa N Nomngongo
- Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, Johannesburg, South Africa.,DSI/NRF SARChI Chair, Nanotechnology for Water, University of Johannesburg, Doornfontein, South Africa.,DSI/Mintek Nanotechnology Innovation Centre, University of Johannesburg, Doornfontein, South Africa
| |
Collapse
|
12
|
Xie MR, Cai Y, Liu YQ, Wu ZY. Sensitive colorimetric detection of Pb 2+ by geometric field amplification and surface plasmon resonance visualization. Talanta 2020; 212:120749. [PMID: 32113532 DOI: 10.1016/j.talanta.2020.120749] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 01/13/2020] [Accepted: 01/14/2020] [Indexed: 11/15/2022]
Abstract
Pb2+ is one of the major environmental pollutants, which can be visually detected by surface plasmon resonance of nanoparticles. Paper based analytical device, as a newly developed microfluidic detection platform, is featured in cost-effective and suitable for on-site analysis. In this paper, a sensitive and portable detection method for Pb2+ was proposed, in which Pb2+ was electrokinetically stacked on the paper fluidic channel by geometric field amplification effect and visualized online by glutathione-modified silver nanoparticles. Colorimetric quantification of the visualized stacking band was conducted by smart phone camera. To avoid unfavorable influence from pH change on the surface plasmon resonance visualization, field amplification effect was introduced by geometric design of the paper fluidic channel. The enriched Pb2+ was clearly visible on the paper substrate, and the stacking band intensity was about four orders of magnitude enhanced, comparing to the intensity without stacking. A linear response to Pb2+ was observed in the range of 0.3-7.0 μM (R2 = 0.997) with a limit of detection of 86 nM and a limit of quantity of 0.28 μM. The established method was used in the detection of Pb2+ from river and lake water samples, and the results were confirmed by atomic absorption spectroscopy method.
Collapse
Affiliation(s)
- Mao-Rong Xie
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Yu Cai
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Yu-Qi Liu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Zhi-Yong Wu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China.
| |
Collapse
|
13
|
Rodríguez-Maese R, Ferrer L, Cerdà V, Leal LO. Fully automatic system for lead monitoring in water. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104550] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Li YK, Wang XY, Liu X, Yang T, Chen ML, Wang JH. Ensuring high selectivity for preconcentration and detection of ultra-trace cadmium using a phage-functionalized metal–organic framework. Analyst 2020; 145:5280-5288. [DOI: 10.1039/d0an00944j] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
A phage functionalized metal–organic framework for selective preconcentration and detection of trace cadmium.
Collapse
Affiliation(s)
- Yi-Kun Li
- Research Center for Analytical Sciences
- Department of Chemistry
- College of Sciences
- Northeastern University
- Shenyang 110819
| | - Xiao-Yan Wang
- Research Center for Analytical Sciences
- Department of Chemistry
- College of Sciences
- Northeastern University
- Shenyang 110819
| | - Xun Liu
- Research Center for Analytical Sciences
- Department of Chemistry
- College of Sciences
- Northeastern University
- Shenyang 110819
| | - Ting Yang
- Research Center for Analytical Sciences
- Department of Chemistry
- College of Sciences
- Northeastern University
- Shenyang 110819
| | - Ming-Li Chen
- Research Center for Analytical Sciences
- Department of Chemistry
- College of Sciences
- Northeastern University
- Shenyang 110819
| | - Jian-Hua Wang
- Research Center for Analytical Sciences
- Department of Chemistry
- College of Sciences
- Northeastern University
- Shenyang 110819
| |
Collapse
|
15
|
Yarmohammadi M, Mirzaei M, Samadi-Maybodi A. Application of Ion Exchange, Solvent Extraction, and Ion-Imprinted Methods for Separation of 203Pb. RADIOCHEMISTRY 2019. [DOI: 10.1134/s1066362219060146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
16
|
Development of a new ion-imprinted polymer (IIP) with Cd2+ ions based on divinylbenzene copolymers containing amidoxime groups. Polym Bull (Berl) 2019. [DOI: 10.1007/s00289-019-02842-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
17
|
Shirani M, Habibollahi S, Akbari A. Centrifuge-less deep eutectic solvent based magnetic nanofluid-linked air-agitated liquid–liquid microextraction coupled with electrothermal atomic absorption spectrometry for simultaneous determination of cadmium, lead, copper, and arsenic in food samples and non-alcoholic beverages. Food Chem 2019; 281:304-311. [DOI: 10.1016/j.foodchem.2018.12.110] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 12/14/2018] [Accepted: 12/29/2018] [Indexed: 11/26/2022]
|
18
|
Preconcentration of Pb(II) by using Mg(II)-doped NiFe2O4 nanoparticles as a magnetic solid phase extraction agent. Mikrochim Acta 2018; 185:343. [DOI: 10.1007/s00604-018-2874-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Accepted: 06/17/2018] [Indexed: 12/23/2022]
|
19
|
A simple and green deep eutectic solvent based air assisted liquid phase microextraction for separation, preconcentration and determination of lead in water and food samples by graphite furnace atomic absorption spectrometry. J Mol Liq 2018. [DOI: 10.1016/j.molliq.2018.03.034] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
20
|
Khayatian G, Moradi M, Hassanpoor S. MnO2/3MgO Nanocomposite for Preconcentration and Determination of Trace Copper and Lead in Food and Water by Flame Atomic Absorption Spectrometry. JOURNAL OF ANALYTICAL CHEMISTRY 2018. [DOI: 10.1134/s1061934818050088] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
21
|
Wirawan T, Supriyanto G, Soegianto A. Synthesis, characterization, and application of novel Zn(II)-ionic imprinted polymer for preconcentration of Zn(II) ions from aqueous solution. ACTA ACUST UNITED AC 2018. [DOI: 10.1088/1757-899x/349/1/012064] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
22
|
Samadi-Maybodi A, Mirzaei M, Yarmohammadi M. Magnetized ion-imprinted polymer-coated nano-particles for selective separation and trace detection of 203Pb using gamma-ray spectrometry. J Radioanal Nucl Chem 2018. [DOI: 10.1007/s10967-018-5822-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
23
|
Preparation and application of nanocomposite based on imprinted poly(methacrylic acid)-PAN/MWCNT as a new electrochemical selective sensing platform of Pb2+ in water samples. J Electroanal Chem (Lausanne) 2017. [DOI: 10.1016/j.jelechem.2017.07.033] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
24
|
Moussa M, Ndiaye MM, Pinta T, Pichon V, Vercouter T, Delaunay N. Selective solid phase extraction of lanthanides from tap and river waters with ion imprinted polymers. Anal Chim Acta 2017; 963:44-52. [DOI: 10.1016/j.aca.2017.02.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Revised: 02/07/2017] [Accepted: 02/09/2017] [Indexed: 10/20/2022]
|
25
|
On-line micro-solid phase preconcentration of Cd2+ coupled to TS-FF-AAS using a novel ion-selective bifunctional hybrid imprinted adsorbent. Microchem J 2017. [DOI: 10.1016/j.microc.2016.11.013] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
26
|
Yilmaz V, Yilmaz H, Arslan Z, Leszczynski J. Novel Imprinted Polymer for the Preconcentration of Cadmium with Determination by Inductively Coupled Plasma Mass Spectrometry. ANAL LETT 2017; 50:482-499. [PMID: 28239183 DOI: 10.1080/00032719.2016.1182544] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
A novel Cd(II)-imprinted polymer was prepared with chemical immobilization approach by using N-methacryloyl-L-histidine as a vinylated chelating agent for on-line solid phase extraction of Cd(II) for determination by inductively coupled plasma mass spectrometry. Cd(II)-monomer complex was synthesized and copolymerized via bulk polymerization method in the presence of ethyleneglycoldimethacrylate cross-linker. The resulting polymer was leached with 1.0 mol L-1 HNO3 to generate the cavities in the polymer for Cd(II) ions. The experimental conditions, including load pH, solution flow rate, and eluent concentration for effective sorption of Cd(II) were optimized using a minicolumn of the imprinted polymer. A volume of 5.0 mL sample 5 μg L-1 Cd(II) solution at pH 6.5 was loaded onto the column at 2.0 mL min-1 by using a sequential injection system (FIALab 3200) followed by elution with 1.0 mL of 0.75 mol L-1 HNO3. The relative selectivity coefficients of the imprinted polymer for Cd(II) were 38.5, 3.5, 3.0, 2.5 and 6.0 in the presence of Cu(II), Ni(II), Zn(II), Co(II) and Pb(II), respectively. Computational calculations revealed that the selectivity of the imprinted polymer was mediated by the stability of Cd(II)-N-methacryloyl-L-histidine complex which was far more stable than those of commonly used monomers, such as 4-vinyl pyridine, methacrylic acid and vinylimidazole. The detection limit (3s) and relative standard deviation (%) were found to be 0.004 μg L-1 and 3.2%, respectively. The method was validated by analysis of seawater certified reference material (CASS-4) and successfully applied to the determination of Cd(II) in coastal seawater and estuarine water samples.
Collapse
Affiliation(s)
- Vedat Yilmaz
- Department of Chemistry and Biochemistry, Jackson State University, Jackson, MS, USA; Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri, Turkey
| | - Hayriye Yilmaz
- Department of Chemistry and Biochemistry, Jackson State University, Jackson, MS, USA; Deparment of Biomedical Devices and Technologies, Kayseri Vocational School, Erciyes University, Kayseri, Turkey
| | - Zikri Arslan
- Department of Chemistry and Biochemistry, Jackson State University, Jackson, MS, USA
| | - Jerzy Leszczynski
- Department of Chemistry and Biochemistry, Jackson State University, Jackson, MS, USA
| |
Collapse
|
27
|
Pourjavid MR, Arabieh M, Yousefi SR, Akbari Sehat A. Interference free and fast determination of manganese(II), iron(III) and copper(II) ions in different real samples by flame atomic absorption spectroscopy after column graphene oxide-based solid phase extraction. Microchem J 2016. [DOI: 10.1016/j.microc.2016.07.008] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
28
|
do Lago AC, Marchioni C, Mendes TV, Wisniewski C, Fadini PS, Luccas PO. Ion Imprinted Polymer for Preconcentration and Determination of Ultra-Trace Cadmium, Employing Flow Injection Analysis with Thermo Spray Flame Furnace Atomic Absorption Spectrometry. APPLIED SPECTROSCOPY 2016; 70:1842-1850. [PMID: 27449370 DOI: 10.1177/0003702816658669] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Accepted: 01/04/2016] [Indexed: 06/06/2023]
Abstract
This work proposes a preconcentration method using an ion imprinted polymer (IIP) for determination of cadmium, in several samples, employing a mini-column filled with the polymer coupled into a flow injection analysis system with detection by thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS). The polymer was synthesized via bulk using methacrylic acid and vinylimidazole as a functional monomer. For the FIA system initial assessment, the variables: pH, eluent concentration and buffer concentration were studied, employing a 23 full factorial design. To obtain the optimum values for each significant variable, a Doehlert matrix was employed. After the optimization conditions as: pH 5.8, eluent (HNO3) concentration of 0.48 mol L-1 and buffer concentration of 0.01 mol L-1, were adopted. The proposed method showed a linear response in the range of 0.081-10.0 μg L-1, limits detection and quantification of 0.024 and 0.081 μg L-1, respectively; preconcentration factor of 165, consumptive index of 0.06 mL, concentration efficiency 132 min-1, and frequency of readings equal to 26 readings h-1 The accuracy was checked by analysis of certified reference materials for trace metals and recovery tests. The obtained results were in agreement with 95% confidence level (t-test). The method was adequate to apply in samples of: jewelry (earrings) (2.38 ± 0.28 μg kg-1), black tea (1.09 ± 0.15 μg kg-1), green tea (3.85 ± 0.13 μg kg-1), cigarette tobacco (38.27 ± 0.22 μg kg-1), and hair (0.35 ± 0.02 μg kg-1).
Collapse
Affiliation(s)
- Ayla Campos do Lago
- Universidade Federal de São Carlos (UFSCar-SP), Departamento de Química, São Carlos, SP, Brazil
| | - Camila Marchioni
- Universidade Federal de Alfenas (UNIFAL-MG), Instituto de Química, Alfenas, MG, Brazil
| | - Tássia Venga Mendes
- Universidade Federal de Alfenas (UNIFAL-MG), Instituto de Química, Alfenas, MG, Brazil
| | - Célio Wisniewski
- Universidade Federal de Alfenas (UNIFAL-MG), Instituto de Química, Alfenas, MG, Brazil
| | - Pedro Sergio Fadini
- Universidade Federal de São Carlos (UFSCar-SP), Departamento de Química, São Carlos, SP, Brazil
| | - Pedro Orival Luccas
- Universidade Federal de Alfenas (UNIFAL-MG), Instituto de Química, Alfenas, MG, Brazil
| |
Collapse
|
29
|
Selective dispersive micro solid-phase extraction using oxidized multiwalled carbon nanotubes modified with 1,10-phenanthroline for preconcentration of lead ions. Food Chem 2016; 209:37-42. [DOI: 10.1016/j.foodchem.2016.04.015] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2015] [Revised: 03/16/2016] [Accepted: 04/10/2016] [Indexed: 12/25/2022]
|
30
|
Falahnejad M, Zavvar Mousavi H, Shirkhanloo H, Rashidi A. Preconcentration and separation of ultra-trace amounts of lead using ultrasound-assisted cloud point-micro solid phase extraction based on amine functionalized silica aerogel nanoadsorbent. Microchem J 2016. [DOI: 10.1016/j.microc.2015.11.026] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
31
|
Khayatian G, Jodan M, Hassanpoor S, Mohebbi S. Determination of trace amounts of cadmium, copper and nickel in environmental water and food samples using GO/MgO nanocomposite as a new sorbent. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2016. [DOI: 10.1007/s13738-015-0798-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
32
|
Fu J, Wang X, Li J, Ding Y, Chen L. Synthesis of multi-ion imprinted polymers based on dithizone chelation for simultaneous removal of Hg2+, Cd2+, Ni2+ and Cu2+ from aqueous solutions. RSC Adv 2016. [DOI: 10.1039/c6ra07785d] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A multi-ion imprinted polymer strategy based on dithizone chelation for simultaneous removal of multiple ions in aqueous solution.
Collapse
Affiliation(s)
- Junqing Fu
- Key Laboratory of Life-Organic Analysis of Shandong Province
- College of Chemistry and Chemical Engineering
- Qufu Normal University
- Qufu 273165
- China
| | - Xiaoyan Wang
- Key Laboratory of Coastal Environmental Processes and Ecological Remediation
- Yantai Institute of Coastal Zone Research
- Chinese Academy of Sciences
- Yantai 264003
- China
| | - Jinhua Li
- Key Laboratory of Coastal Environmental Processes and Ecological Remediation
- Yantai Institute of Coastal Zone Research
- Chinese Academy of Sciences
- Yantai 264003
- China
| | - Yangjun Ding
- Key Laboratory of Life-Organic Analysis of Shandong Province
- College of Chemistry and Chemical Engineering
- Qufu Normal University
- Qufu 273165
- China
| | - Lingxin Chen
- Key Laboratory of Life-Organic Analysis of Shandong Province
- College of Chemistry and Chemical Engineering
- Qufu Normal University
- Qufu 273165
- China
| |
Collapse
|
33
|
Gomes JM, Donnici CL, Corrêa Júnior JD, da Silva JBB. Validation of Methods Employing Fast Alkaline Solubilization to Determine Cadmium in Fish Liver, Spleen, Gills and Muscle by Graphite Furnace Atomic Absorption Spectrometry. Microchem J 2016. [DOI: 10.1016/j.microc.2015.10.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
34
|
HU S, XIONG X, HUANG S, LAI X. Preparation of Pb(II) Ion Imprinted Polymer and Its Application as the Interface of an Electrochemical Sensor for Trace Lead Determination. ANAL SCI 2016; 32:975-80. [DOI: 10.2116/analsci.32.975] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Shanling HU
- College of Chemistry and Chemical Engineering, Gannan Normal University
| | - Xiaodong XIONG
- College of Chemistry and Chemical Engineering, Gannan Normal University
| | - Shuiying HUANG
- College of Chemistry and Chemical Engineering, Gannan Normal University
| | - Xiaoqi LAI
- College of Chemistry and Chemical Engineering, Gannan Normal University
| |
Collapse
|
35
|
Zarco-Fernández S, Mancheño M, Muñoz-Olivas R, Cámara C. A new specific polymeric material for mercury speciation: Application to environmental and food samples. Anal Chim Acta 2015; 897:109-15. [DOI: 10.1016/j.aca.2015.09.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2015] [Revised: 07/30/2015] [Accepted: 09/07/2015] [Indexed: 10/23/2022]
|
36
|
Frentiu T, Darvasi E, Butaciu S, Ponta M, Petreus D, Etz R, Frentiu M. Application of low-cost electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for simultaneous determination of Cd and Pb in environmental samples. Microchem J 2015. [DOI: 10.1016/j.microc.2015.03.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
37
|
Determination of Cu2+, Zn2+ and Pb2+ in biological and food samples by FAAS after preconcentration with hydroxyapatite nanorods originated from eggshell. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 52:288-96. [DOI: 10.1016/j.msec.2015.03.061] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Revised: 02/22/2015] [Accepted: 03/20/2015] [Indexed: 11/21/2022]
|
38
|
Hande PE, Samui AB, Kulkarni PS. Highly selective monitoring of metals by using ion-imprinted polymers. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2015; 22:7375-404. [PMID: 25663338 DOI: 10.1007/s11356-014-3937-x] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2014] [Accepted: 12/01/2014] [Indexed: 05/27/2023]
Abstract
Ion imprinting technology is one of the most promising tools in separation and purification sciences because of its high selectivity, good stability, simplicity and low cost. It has been mainly used for selective removal, preconcentration, sensing and few miscellaneous fields. In this review article, recent methodologies in the synthesis of IIPs have been discussed. For several applications, different parameters of IIP including complexing and leaching agent, pH, relative selectivity coefficient, detection limit and adsorption capacity have been evaluated and an attempt has been made to generalize. Biomedical applications mostly include selective removal of toxic metals from human blood plasma and urine samples. Wastewater treatment involves selective removal of highly toxic metal ions like Hg(II), Pb(II), Cd(II), As(V), etc. Preconcentration covers recovery of economically important metal ions such as gold, silver, platinum and palladium. It also includes selective preconcentration of lanthanides and actinides. In sensing, various IIP-based sensors have been fabricated for detection of toxic metal ions. This review article includes almost all metal ions based on the ion-imprinted polymer. At the end, the future outlook section presents the discussion on the advancement, corresponding merits and the need of continued research in few specific areas. Graphical Abstract IIPs for the selective monitoring of metals.
Collapse
Affiliation(s)
- Pankaj E Hande
- Energy and Environment Laboratory, Department of Applied Chemistry, Defence Institute of Advanced Technology, Deemed University, Pune, 411025, India
| | | | | |
Collapse
|
39
|
Shahi S, Nateghi MR. Double preconcentration of trace amounts of cadmium in nail samples and measurement by differential pulse voltammetry. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2015; 94:468-473. [PMID: 25638441 DOI: 10.1007/s00128-015-1484-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Accepted: 01/24/2015] [Indexed: 06/04/2023]
Abstract
Cadion was coated on carbon powder and used as a solid phase for selective extraction and preconcentration of cadmium ions. Complexed cadmium ions were eluted from solid phase by 5 mL, nitric acid (2.0 M) with the flow rate of 2 mL min(-1).The resulted solution was used for accumulation of the cadmium metal at the surface of the carbon paste electrode at -1.3 V reduction potential. Finally, cadmium was reoxidized and the differential pulse voltammogram recorded at the potential range of -0.55 to -0.2 V. Calibration graph was plotted in the concentration range of 0.5-50 μg L(-1) of cadmium. Detection limit 0.06 μg L(-1) was calculated based on the 3 Sb/m. The RSD was 9.13 % (n = 4) for cadmium concentration of 10 μg L(-1) with preconcentration factor of 100. Method was successfully used for the determination of cadmium in finger nail samples and after spiking the samples, the recoveries were evaluated >96 %.
Collapse
Affiliation(s)
- Somayeh Shahi
- Department of Chemistry, Yazd Branch, Islamic Azad University, Yazd, Iran
| | | |
Collapse
|
40
|
Wu L, Fu X, Liu H, Li J, Song Y. Comparative study of graphene nanosheet- and multiwall carbon nanotube-based electrochemical sensor for the sensitive detection of cadmium. Anal Chim Acta 2014; 851:43-8. [DOI: 10.1016/j.aca.2014.08.021] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2014] [Revised: 08/07/2014] [Accepted: 08/11/2014] [Indexed: 10/24/2022]
|
41
|
Silica nanoparticles doped with a europium(III) complex and coated with an ion imprinted polymer for rapid determination of copper(II). Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1382-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
42
|
Modified multiwall carbon nanotubes supported on graphite as a suitable solid nano-sorbent for selective separation and preconcentration of trace amounts of cadmium and lead ions. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2014. [DOI: 10.1007/s13738-014-0503-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|