1
|
Xu SN, Feng YJ, Luo SY, Song R, Yan XQ. A π-hole bond functionalized magnetic nanosorbent for the solid phase extraction of 15 polycyclic aromatic hydrocarbons from environmental water samples. J Chromatogr A 2025; 1741:465621. [PMID: 39742682 DOI: 10.1016/j.chroma.2024.465621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Revised: 12/19/2024] [Accepted: 12/20/2024] [Indexed: 01/04/2025]
Abstract
A new type of sorbent functionalized with π-hole bond, perfluoronaphthyl bonded magnetic nanosorbent (Fe3O4@SiO2-C10F7), was designed and synthesized. The morphology, structure and magnetic properties of the sorbent were characterized. The results of a comparative experiment with naphthyl bonded magnetic nanosorbent (Fe3O4@SiO2-C10H7) revealed that the π-hole bonds between perfluoronaphthyl and PAHs improved adsorbilities for PAHs in water compared to the traditional π-π interactions between naphthyl and PAHs. A new MSPE-HPLC method for the simultaneous detection of 15 PAHs in environmental water was established based on Fe3O4@SiO2-C10F7 sorbent. This method requires less sorbent, offers high sensitivity, and allows for easy operation without solvent replacement. The results revealed that the method exhibited good linearity in the range of 0.05-12 ng·mL-1, and the recoveries of the PAHs in real samples ranged from 70.1 % to 108 % at the spiked concentration of 0.5 ng·mL-1, except for volatile naphthalene (41.8 %). The LODs were 0.2-13.4 ng·L-1. The results demonstrate the effectiveness of π-hole bond in extraction of PAHs, surpassing traditional π-π interaction even in water. The application of π-hole bond in sorbents offers a new interaction mode or retention mechanism in extraction processes, undoubtedly providing a fresh perspective for the design of selective sorbents.
Collapse
Affiliation(s)
- Shao Nan Xu
- Shanxi Key Laboratory of Environmental Health Impairment and Prevention, MOE Key Laboratory of Coal Environmental Pathogenicity and Prevention, School of Public Health, Shanxi Medical University, Taiyuan 030001, PR China
| | - Ya Jie Feng
- Shanxi Key Laboratory of Environmental Health Impairment and Prevention, MOE Key Laboratory of Coal Environmental Pathogenicity and Prevention, School of Public Health, Shanxi Medical University, Taiyuan 030001, PR China
| | - Si Yan Luo
- Shanxi Key Laboratory of Environmental Health Impairment and Prevention, MOE Key Laboratory of Coal Environmental Pathogenicity and Prevention, School of Public Health, Shanxi Medical University, Taiyuan 030001, PR China
| | - Rui Song
- Shanxi Key Laboratory of Environmental Health Impairment and Prevention, MOE Key Laboratory of Coal Environmental Pathogenicity and Prevention, School of Public Health, Shanxi Medical University, Taiyuan 030001, PR China
| | - Xiao Qing Yan
- Shanxi Key Laboratory of Environmental Health Impairment and Prevention, MOE Key Laboratory of Coal Environmental Pathogenicity and Prevention, School of Public Health, Shanxi Medical University, Taiyuan 030001, PR China.
| |
Collapse
|
2
|
Benedetti B, Tronconi A, Turrini F, Di Carro M, Donno D, Beccaro GL, Boggia R, Magi E. Determination of polycyclic aromatic hydrocarbons in bud-derived supplements by magnetic molecular imprinted microparticles and GC-MS: D-optimal design for a fast method optimization. Sci Rep 2023; 13:17544. [PMID: 37845244 PMCID: PMC10579315 DOI: 10.1038/s41598-023-44398-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 10/07/2023] [Indexed: 10/18/2023] Open
Abstract
Within the world of natural food supplements, organic extracts deriving from young plant meristematic tissue (bud-derivatives) are becoming attractive, thanks to their richness in bioactive molecules. This natural source is scarce, but every year, tons of plant material, including buds, come from city pruning. If this sustainable source is rather promising from a circular economy point of view, the safety of the obtained supplements must be assessed. In fact, anthropic microcontaminants, such as polycyclic aromatic hydrocarbons (PAHs), could adsorb onto the urban buds, leading to a possible contamination of the bud-derivatives. In this study, we developed a magnetic dispersive solid phase extraction (m-dSPE) based on molecularly imprinted microparticles, combined with GC-MS, to quantify the 16 priority PAHs in such extracts. The D-optimal experimental design was implemented to maximize analytes' recovery with the smallest set of experiments. The optimized method was characterized by great selectivity thanks to the molecular imprinted polymer and ease of use provided by m-dSPE. Moreover, it complies with green principles, thanks to the minimum consumption of organic solvent (1.5 mL of acetone per sample). The recoveries ranged from 76 to 100% and procedural precision was below 10% for most PAHs. Despite the matrix complexity, low quantification limits (0.7-12.6 μg kg-1) were reached. This guaranteed the PAHs' quantitation at levels below those indicated as safe by a European Community regulation on food supplements. None of the analyzed samples, coming from different anthropically impacted areas, showed concerning PAHs levels.
Collapse
Affiliation(s)
- Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genoa, Italy
| | - Arianna Tronconi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genoa, Italy
- Paul Scherrer Institut, Forschungsstrasse 111, Villigen, 5303, Switzerland
| | - Federica Turrini
- Department of Pharmacy, University of Genoa, Viale Cembrano 4, 16148, Genoa, Italy
| | - Marina Di Carro
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genoa, Italy
| | - Dario Donno
- Department of Agriculture, Forestry and Food Science, University of Turin, Largo Braccini 2, 10095, Grugliasco (TO), Italy
| | - Gabriele Loris Beccaro
- Department of Agriculture, Forestry and Food Science, University of Turin, Largo Braccini 2, 10095, Grugliasco (TO), Italy
| | - Raffaella Boggia
- Department of Pharmacy, University of Genoa, Viale Cembrano 4, 16148, Genoa, Italy
| | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, 16146, Genoa, Italy.
| |
Collapse
|
3
|
Benedetti B, Di Carro M, Scapuzzi C, Magi E. Solvent-Free Determination of Selected Polycyclic Aromatic Hydrocarbons in Plant Material Used for Food Supplements Preparation: Optimization of a Solid Phase Microextraction Method. Molecules 2023; 28:5937. [PMID: 37630189 PMCID: PMC10459292 DOI: 10.3390/molecules28165937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/25/2023] [Accepted: 08/05/2023] [Indexed: 08/27/2023] Open
Abstract
The exploitation of waste and by-products in various applications is becoming a cornerstone of the circular economy. A range of biomasses can be employed to produce food supplements. An example is a particular extract obtained from plant buds (rich in bioactive molecules), which can be easily retrieved from cities' pruning. In order to safely use this material, its possible contamination by organic pollutants needs to be estimated. A green and simple method to detect priority polycyclic aromatic hydrocarbons (PAHs) in bud samples by head space solid phase microextraction coupled to GC-MS was developed. This strategy, optimized through experimental design and response surface methodology, requires a minimal sample pre-treatment and negligible solvent consumption. The final method was found to be accurate and sensitive for PAHs with mass up to 228 Da. For these analytes, satisfactory figures of merit were achieved, with detection limits in the range 1-4 ng g-1, good inter-day precision (relative standard deviation in the range 4-11%), and satisfactory accuracy (88-105%), along with specificity guaranteed by the selected ion monitoring detection. The method was applied to bud samples coming from differently polluted areas, thus helping in estimating the safety of their use for the production of food supplements.
Collapse
Affiliation(s)
| | | | | | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, 16146 Genoa, Italy; (B.B.); (M.D.C.); (C.S.)
| |
Collapse
|
4
|
Application of Molecularly Imprinted Electrochemical Biomimetic Sensors for Detecting Small Molecule Food Contaminants. Polymers (Basel) 2022; 15:polym15010187. [PMID: 36616536 PMCID: PMC9824611 DOI: 10.3390/polym15010187] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 12/26/2022] [Accepted: 12/27/2022] [Indexed: 01/04/2023] Open
Abstract
Environmental chemical contaminants in food seriously impact human health and food safety. Successful detection methods can effectively monitor the potential risk of emerging chemical contaminants. Among them, molecularly imprinted polymers (MIPs) based on electrochemical biomimetic sensors overcome many drawbacks of conventional detection methods and offer opportunities to detect contaminants with simple equipment in an efficient, sensitive, and low-cost manner. We searched eligible papers through the Web of Science (2000-2022) and PubMed databases. Then, we introduced the sensing mechanism of MIPs, outlined the sample preparation methods, and summarized the MIP characterization and performance. The classification of electrochemistry, as well as its advantages and disadvantages, are also discussed. Furthermore, the representative application of MIP-based electrochemical biomimetic sensors for detecting small molecular chemical contaminants, such as antibiotics, pesticides, toxins, food additives, illegal additions, organic pollutants, and heavy metal ions in food, is demonstrated. Finally, the conclusions and future perspectives are summarized and discussed.
Collapse
|
5
|
Tian Y, Xu Z, Liu Z, Si X, Zhang F, Jiang W. Fe 3O 4@SiO 2@VAN Nanoadsorbent Followed by GC-MS for the Determination of Polycyclic Aromatic Hydrocarbons at Ultra-Trace Levels in Environmental Water Samples. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:2921. [PMID: 36079959 PMCID: PMC9458231 DOI: 10.3390/nano12172921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 08/22/2022] [Accepted: 08/23/2022] [Indexed: 06/15/2023]
Abstract
In the present study, silica-coated magnetic nanoparticles functionalized with vancomycin (Fe3O4@SiO2@VAN) were synthesized. The Fe3O4@SiO2@VAN nanocomposite was used as a sorbent for the magnetic solid-phase extraction (MSPE) of polycyclic aromatic hydrocarbons (PAHs) from environmental water, followed by GC-MS. The nanocomposite was characterized by Fourier-transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and nitrogen sorption. Various experimental parameters were optimized, including extraction condition and desorption condition. Results show that Fe3O4@SiO2@VAN combined the advantages of nanomaterials and magnetic separation technology, showing excellent dispersibility and high selectivity for PAHs in environmental water sample. Under the optimal extraction conditions, an analytical method was established with the sensitive limit of detection (LOD) of 0.03-0.16 μg L-1. The method was successfully applied for the analysis of environmental water samples. The relative standard deviations (%) were in the range of 0.50-12.82%, and the extraction recovery (%) was in the range of 82.48% and 116.32%. MSPE-coupled gas chromatography-mass spectrometry quantification of PAHs is an accurate and repeatable method for the monitoring of PAH accumulation in environmental water samples. It also provides an effective strategy for the tracing and quantification of other environmental pollutants in complex samples.
Collapse
Affiliation(s)
- Yu Tian
- Faculty of Science, Kunming University of Science and Technology, Kunming 650500, China
| | - Zhigang Xu
- Faculty of Science, Kunming University of Science and Technology, Kunming 650500, China
| | - Zhimin Liu
- Faculty of Science, Kunming University of Science and Technology, Kunming 650500, China
| | - Xiaoxi Si
- Faculty of Environmental Science & Engineering, Kunming University of Science and Technology, Kunming 650500, China
- Yunnan Key Laboratory of Tobacco Chemistry, R&D Center of China Tobacco Yunnan Industrial Co., Ltd., Kunming 650231, China
| | - Fengmei Zhang
- Yunnan Key Laboratory of Tobacco Chemistry, R&D Center of China Tobacco Yunnan Industrial Co., Ltd., Kunming 650231, China
| | - Wei Jiang
- Yunnan Key Laboratory of Tobacco Chemistry, R&D Center of China Tobacco Yunnan Industrial Co., Ltd., Kunming 650231, China
| |
Collapse
|
6
|
Hojjati-Najafabadi A, Mansoorianfar M, Liang T, Shahin K, Karimi-Maleh H. A review on magnetic sensors for monitoring of hazardous pollutants in water resources. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 824:153844. [PMID: 35176366 DOI: 10.1016/j.scitotenv.2022.153844] [Citation(s) in RCA: 123] [Impact Index Per Article: 41.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 02/01/2022] [Accepted: 02/09/2022] [Indexed: 06/14/2023]
Abstract
Water resources have long been of interest to humans and have become a serious issue in all aspects of human life. The disposal of hazardous pollutants in water resources is one of the biggest global concerns and poses many risks to human health and aquatic life. Therefore, the control of hazardous pollutants in water resources plays an important role, when it comes to evaluating water quality. Due to low toxicity, good electrical conductivity, facile functionalization, and easy preparation, magnetic materials have become a good alternative in recent years to control hazardous pollutants in water resources. In the present study, the idea of using magnetic sensors in controlling and monitoring of pharmaceuticals, pesticides, heavy metals, and organic pollutants have been reviewed. The water pollutants in drinking water, groundwater, surface water, and seawater have been discussed. The toxicology of water hazardous pollutants has also been reviewed. Then, the magnetic materials were discussed as sensors for controlling and monitoring pollutants. Finally, future remarks and perspectives on magnetic nanosensors for controlling hazardous pollutants in water resources and environmental applications were explained.
Collapse
Affiliation(s)
- Akbar Hojjati-Najafabadi
- College of Rare Earths, Jiangxi University of Science and Technology, No. 86, Hongqi Ave., Ganzhou, Jiangxi 341000, PR China; Faculty of Materials, Metallurgy and Chemistry, School of Materials Science and Engineering, Jiangxi University of Science and Technology, Ganzhou 341000, PR China.
| | - Mojtaba Mansoorianfar
- CAS Key Laboratory for Nano-Bio Interface, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, China
| | - Tongxiang Liang
- College of Rare Earths, Jiangxi University of Science and Technology, No. 86, Hongqi Ave., Ganzhou, Jiangxi 341000, PR China
| | - Khashayar Shahin
- Center for Microbes, Development, and Health (CMDH), Institute Pasteur of Shanghai, Chinese Academy of Sciences, Shanghai 200025, China
| | - Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, Chengdu 611731, PR China; Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran; Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, 2028 Johannesburg, South Africa.
| |
Collapse
|
7
|
Yahyapour M, Ranjbar M, Mohadesi A, Rejaeinegad M. Determination of Buprenorphine (BUP) with Molecularly Imprinted Polymer Zn/La
3+
Metal Organic Framework on Modified Glassy Carbon Electrode (GCE). ELECTROANAL 2022. [DOI: 10.1002/elan.202100266] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Moghadaseh Yahyapour
- Neuroscience Research Center, Institute of Neuropharmacology Kerman University of Medical Sciences Kerman Iran
| | - Mehdi Ranjbar
- Pharmaceutics Research Center, Institute of Neuropharmacology Kerman University of Medical Sciences P.O. Box: 76175–493 Kerman 76169-11319 Iran
| | - Alireza Mohadesi
- Department of Chemistry Payame Noor University Tehran 19395-4697 Iran
| | - Moslem Rejaeinegad
- Department of Chemistry, Kerman Branch Islamic Azad University Kerman Iran
| |
Collapse
|
8
|
Nicholls IA, Golker K, Olsson GD, Suriyanarayanan S, Wiklander JG. The Use of Computational Methods for the Development of Molecularly Imprinted Polymers. Polymers (Basel) 2021; 13:2841. [PMID: 34502881 PMCID: PMC8434026 DOI: 10.3390/polym13172841] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 08/16/2021] [Accepted: 08/19/2021] [Indexed: 12/29/2022] Open
Abstract
Recent years have witnessed a dramatic increase in the use of theoretical and computational approaches in the study and development of molecular imprinting systems. These tools are being used to either improve understanding of the mechanisms underlying the function of molecular imprinting systems or for the design of new systems. Here, we present an overview of the literature describing the application of theoretical and computational techniques to the different stages of the molecular imprinting process (pre-polymerization mixture, polymerization process and ligand-molecularly imprinted polymer rebinding), along with an analysis of trends within and the current status of this aspect of the molecular imprinting field.
Collapse
Affiliation(s)
- Ian A. Nicholls
- Bioorganic & Biophysical Chemistry Laboratory, Linnaeus University Centre for Biomaterials Chemistry, Department of Chemistry & Biomedical Sciences, Linnaeus University, SE-391 82 Kalmar, Sweden; (K.G.); (G.D.O.); (S.S.); (J.G.W.)
| | | | | | | | | |
Collapse
|
9
|
Liu Y, Lian Z, Li F, Majid A, Wang J. Review on molecular imprinting technology and its application in pre-treatment and detection of marine organic pollutants. MARINE POLLUTION BULLETIN 2021; 169:112541. [PMID: 34052587 DOI: 10.1016/j.marpolbul.2021.112541] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 05/17/2021] [Accepted: 05/19/2021] [Indexed: 05/17/2023]
Abstract
Molecular imprinting technology (MIT) has been considered as an attractive method to produce artificial receptors with the memory of size, shape and functional groups of the templates and has become an emerging technique with the potential in various fields due to recognitive specificity, high efficient selectivity and mechanical stability, which can effectively remove background interference and is suitable for the pre-treatment and analysis of trace level substances in complex matrix samples. Nearly 100 papers about the application of MIT in the detection of marine pollutants were found through Science Citation Index Expanded (SCIE). On this basis, combined with the application of MIT in other fields, the pre-treatment process of marine environmental samples was summarized and the potential of four types of different molecularly imprinted materials in the pre-treatment and detection of marine organic pollutants (including antibiotics, triazines, organic dyes, hormones and shellfish toxins) samples was evaluated, which provides the innovative configurations and progressive applications for the analysis of marine samples, and also highlights future trends and perspectives in the emerging research field.
Collapse
Affiliation(s)
- Yuhua Liu
- Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao 266100, China
| | - Ziru Lian
- Marine College, Shandong University, Weihai 264209, China
| | - Fangfang Li
- Shandong Institute for Food and Drug Control, Jinan 250000, China
| | - Abdul Majid
- Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao 266100, China
| | - Jiangtao Wang
- Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao 266100, China.
| |
Collapse
|
10
|
Köse K, Kehribar DY, Uzun L. Molecularly imprinted polymers in toxicology: a literature survey for the last 5 years. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:35437-35471. [PMID: 34024002 DOI: 10.1007/s11356-021-14510-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 05/17/2021] [Indexed: 05/23/2023]
Abstract
The science of toxicology dates back almost to the beginning of human history. Toxic chemicals, which are encountered in different forms, are always among the chemicals that should be investigated in criminal field, environmental application, pharmaceutic, and even industry, where many researches have been carried out studies for years. Almost all of not only drugs but also industrial dyes have toxic side and direct effects. Environmental micropollutants accumulate in the tissues of all living things, especially plants, and show short- or long-term toxic symptoms. Chemicals in forensic science can be known by detecting the effect they cause to the body with the similar mechanism. It is clear that the best tracking tool among analysis methods is molecularly printed polymer-based analytical setups. Different polymeric combinations of molecularly imprinted polymers allow further study on detection or extraction using chromatographic and spectroscopic instruments. In particular, methods used in forensic medicine can detect trace amounts of poison or biological residues on the scene. Molecularly imprinted polymers are still in their infancy and have many variables that need to be developed. In this review, we summarized how molecular imprinted polymers and toxicology intersect and what has been done about molecular imprinted polymers in toxicology by looking at the studies conducted in the last 5 years.
Collapse
Affiliation(s)
- Kazım Köse
- Department of Joint Courses, Hitit University, Çorum, Turkey.
| | - Demet Yalçın Kehribar
- Department of Internal Medicine, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey
| | - Lokman Uzun
- Department of Chemistry, Faculty of Science, Hacettepe University, Ankara, Turkey.
| |
Collapse
|
11
|
Qiao LZ, Yu CM, Sun RT. Preparation of Amino-functionalized Guanidinium Ionic Liquid-Modified Magnetic Materials and Application in Solid-Phase Extraction of Pollutants in Water. JOURNAL OF ANALYSIS AND TESTING 2021. [DOI: 10.1007/s41664-021-00188-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
12
|
Yan XQ, Guo YN, Zheng SJ, Liu QS, Zhang JL. Solid phase extraction of 16 polycyclic aromatic hydrocarbons from environmental water samples by π-hole bonds. J Chromatogr A 2021; 1645:462067. [PMID: 33853009 DOI: 10.1016/j.chroma.2021.462067] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 02/14/2021] [Accepted: 03/11/2021] [Indexed: 01/04/2023]
Abstract
Through theoretical computation, it was demonstrated that perfluorobenzene can form π-hole⋅⋅⋅π bonds with polycyclic aromatic hydrocarbons (PAHs). Then, the π-hole bond was firstly introduced in solid phase extraction in which perfluorobenzene-bonded silica sorbent was synthesized and used for the solid phase extraction of sixteen PAHs in water. Compared with the traditional octadecyl silica sorbent, the perfluorobenzene-bonded silica sorbent showed higher adsorbabilities for the PAHs with 4-6 benzene rings, for which the recoveries increased by approximately 20%. Under the optimized conditions, the proposed SPE-HPLC-FLD/UV method was successfully applied for the analysis of 16 PAHs in river water and waste water samples with the limits of detection ranged from 0.002 to 0.08 μg⋅L-1. In addition, when the perfluorobenzene-bonded silica sorbent compared with the phenyl-bonded silica sorbent, the results indicated that π-hole⋅⋅⋅π bonds between perfluorobenzene and PAHs were stronger than the π-π interactions between the PAHs and benzene in hexane solution, which highlights the remarkable potential for the application of the π-hole bond in the SPE field.
Collapse
Affiliation(s)
- Xiao Qing Yan
- School of Public Health, Shanxi Medical University, Taiyuan 030001, China.
| | - Ya Nan Guo
- School of Public Health, Shanxi Medical University, Taiyuan 030001, China
| | - Su Jin Zheng
- School of Public Health, Shanxi Medical University, Taiyuan 030001, China
| | - Qiu Shuang Liu
- School of Public Health, Shanxi Medical University, Taiyuan 030001, China
| | - Jia Ling Zhang
- School of Public Health, Shanxi Medical University, Taiyuan 030001, China.
| |
Collapse
|
13
|
Nukatsuka I, Satoh R, Kihara S, Kitagawa F. A thin-layer solid-phase extraction-liquid film elution technique used for the enrichment of polycyclic aromatic hydrocarbons in water. J Sep Sci 2021; 44:1989-1997. [PMID: 33605531 DOI: 10.1002/jssc.202001165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 02/15/2021] [Accepted: 02/16/2021] [Indexed: 12/28/2022]
Abstract
In this article, we propose a novel microsolid-phase extraction and elution technique, which we called the thin-layer solid-phase extraction-liquid film elution technique. The thin-layer solid-phase extraction phase is an octadecylsilylated sol gel- coated porous silica thin film prepared on the outer wall of a test tube, which has a larger surface area for the extraction of the target compounds compared to a conventional solid-phase microextraction phase. After optimization of the extraction procedure for five types of polycyclic aromatic hydrocarbons, the liquid film elution technique was investigated. Liquid film elution is an elution technique wherein the compounds extracted into the thin-layer solid-phase extraction phase are eluted using a small volume of solvent film formed around the extraction phase. The results show that the elution can be carried out using 150 μL of eluent. Enrichment factors between 20 and 34 were obtained for polycyclic aromatic hydrocarbons containing more than four aromatic rings in 10 mL aliquots of aqueous samples. Finally, recoveries of 85-112% were obtained for polycyclic aromatic hydrocarbons containing more than four aromatic rings from spiked natural water samples using the thin-layer solid-phase extraction-liquid film elution technique.
Collapse
Affiliation(s)
- Isoshi Nukatsuka
- Department of Frontier Materials Chemistry, Graduate School of Science and Technology, Hirosaki University, Hirosaki, 036-8561, Japan
| | - Ryota Satoh
- Department of Frontier Materials Chemistry, Graduate School of Science and Technology, Hirosaki University, Hirosaki, 036-8561, Japan
| | - Shigeki Kihara
- Department of Frontier Materials Chemistry, Graduate School of Science and Technology, Hirosaki University, Hirosaki, 036-8561, Japan
| | - Fumihiko Kitagawa
- Department of Frontier Materials Chemistry, Graduate School of Science and Technology, Hirosaki University, Hirosaki, 036-8561, Japan
| |
Collapse
|
14
|
Dehghani Z, Akhond M, Absalan G. Carbon quantum dots embedded silica molecular imprinted polymer as a novel and sensitive fluorescent nanoprobe for reproducible enantioselective quantification of naproxen enantiomers. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105723] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
15
|
Nano-sized FeO@SiO-molecular imprinted polymer as a sorbent for dispersive solid-phase microextraction of melatonin in the methanolic extract of , biological, and water samples. Talanta 2021; 221:121620. [DOI: 10.1016/j.talanta.2020.121620] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 08/29/2020] [Accepted: 08/31/2020] [Indexed: 12/12/2022]
|
16
|
Benedetti B, Caponigro V, Ardini F. Experimental Design Step by Step: A Practical Guide for Beginners. Crit Rev Anal Chem 2020; 52:1015-1028. [PMID: 33258692 DOI: 10.1080/10408347.2020.1848517] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Inside the world of chemometrics, a fundamental role is played by the experimental design. Although introduced almost a century ago (1935), it is still not widely employed by chemists and its usefulness continues to be underestimated. When asking why, the answers are often the following: it is too difficult to apply and too much experimental effort is required. Actually, a deeper knowledge on the topic could offer a different point of view. The aim of the present tutorial is to introduce the experimental design to beginners, by providing the theoretical basic principles as well as a practical guide to use the most common designs, from the experimental plan to the final optimization. Response surface methodology will be discussed, and the main terms related to model computation and statistical evaluations usually performed by software will be explained, in order to give suitable tools to properly use them.
Collapse
Affiliation(s)
- Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Vicky Caponigro
- UCD School of Biosystems and Food Engineering, UCD, Belfield, Dublin, Ireland.,UCD Institute of Food and Health, UCD, Belfield, Dublin, Ireland
| | - Francisco Ardini
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| |
Collapse
|
17
|
Di Carro M, Lluveras-Tenorio A, Benedetti B, Magi E. An innovative sampling approach combined with liquid chromatography-tandem mass spectrometry for the analysis of emerging pollutants in drinking water. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4608. [PMID: 32707599 DOI: 10.1002/jms.4608] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 06/20/2020] [Accepted: 06/27/2020] [Indexed: 06/11/2023]
Abstract
In this work, an innovative sampling and preconcentration method followed by analysis with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization (LC-ESI-MS/MS) was developed for the determination of different emerging pollutants (five anti-inflammatory drugs and one antibacterial agent) in water matrices. Thin-film microextraction blades, consisting of stainless steel blades with a coating made of divinylbenzene, have been employed. The blades, fixed onto a stainless steel support, were mounted on a laboratory stirrer with adjustable speed, immersed in water samples and eluted with methanol. The analytical procedure was developed, carefully optimizing stirring speed and extraction time. A good reproducibility among the blades was observed; quantitation limits at the ng L-1 level were achieved. Calibration curves were constructed by applying the whole procedure to tap water samples, free from analytes, spiked with standards in the concentration range 0.01-2 μg L-1 ; good linearity was obtained, with R2 between 0.9984 and 0.9991. The optimized method was applied to tap and surface waters; two anti-inflammatory drugs were detected at the ng L-1 level in surface water. In one sample, diclofenac and naproxen were measured at 26 ± 5 and 15 ± 1 ng L-1 , respectively; only diclofenac was quantified in the other sample at 14 ± 3 ng L-1 .
Collapse
Affiliation(s)
- Marina Di Carro
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, Genoa 16146, Italy
| | - Anna Lluveras-Tenorio
- National Interuniversity Consortium of Materials Science and Technology, Via G. Giusti 9, Florence, Italy
| | - Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, Genoa 16146, Italy
| | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, Genoa 16146, Italy
| |
Collapse
|
18
|
Zhao M, Hou Z, Lian Z, Qin D, Ge C. Direct extraction and detection of malachite green from marine sediments by magnetic nano-sized imprinted polymer coupled with spectrophotometric analysis. MARINE POLLUTION BULLETIN 2020; 158:111363. [PMID: 32568079 DOI: 10.1016/j.marpolbul.2020.111363] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 06/05/2020] [Accepted: 06/06/2020] [Indexed: 06/11/2023]
Abstract
This research describes the application of magnetic molecularly imprinted nano-sized polymers (MMIPs) for the selective extraction and fast detection of malachite green (MG) from marine sediment samples followed by UV-Vis spectrophotometry. The novel material was prepared by surface imprinting using methacrylic acid as the functional monomer for fixing the template molecules. The polymers obtained at each step were thoroughly studied by transmission electron microscopy, FTIR spectroscopy and thermogravimetric analysis. Simultaneously, the adsorption performances of the resulting nanoparticles were analysed in detail and an excellent affinity with the MG was revealed. Further, the main parameters of magnetic molecular imprinted solid-phase extraction (MMIP-SPE) were screened via multivariate optimization methods. The magnetic nanoparticles were used as special adsorbents to directly extract MG from crude marine sediment extracts. The developed method exhibits satisfactory recoveries from the spiked samples, ranging from 80.40 to 92.96% with an RSD of less than 5.18% (n = 3).
Collapse
Affiliation(s)
- Min Zhao
- Marine College, Shandong University, Weihai 264209, China
| | - Zonghao Hou
- Marine College, Shandong University, Weihai 264209, China
| | - Ziru Lian
- Marine College, Shandong University, Weihai 264209, China.
| | - Dan Qin
- Marine College, Shandong University, Weihai 264209, China
| | - Changzi Ge
- Marine College, Shandong University, Weihai 264209, China
| |
Collapse
|
19
|
Sajid M, Nazal MK, Ihsanullah I. Novel materials for dispersive (micro) solid-phase extraction of polycyclic aromatic hydrocarbons in environmental water samples: A review. Anal Chim Acta 2020; 1141:246-262. [PMID: 33248658 DOI: 10.1016/j.aca.2020.07.064] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 07/24/2020] [Accepted: 07/24/2020] [Indexed: 11/29/2022]
Abstract
Polycyclic aromatic hydrocarbons are hazardous environmental pollutants that possess mutagenic and carcinogenic properties. Generally, the concentrations of PAHs in environmental water samples are very low, and it is challenging to detect such levels directly by the analytical instrumentation. Thus, the extraction of PAHs using suitable extraction methodology is required for sample cleanup and analyte enrichment. Dispersive solid-phase extraction has several advantages over conventional approaches for the extraction of PAHs from environmental water samples. In this article, we critically evaluate the role of different nano and micro sorbent materials employed in the extraction of PAHs. Carbon-based nanomaterials, metal-organic frameworks, polymeric nanocomposites, ionic-liquid based composites, and silica-based materials are explicitly covered. This review also provides insight on functional components of all types of sorbents and their way of interaction with PAHs. The factors affecting the dispersive (micro) solid phase extraction of PAHs such as the design of the sorbent, the ratio of functional material to magnetic core, sample volume, amount of sorbent, extraction and desorption times, desorption solvent and its volume, salt addition, and sample pH are critically appraised. Finally, a brief account on the accomplishments, limitations, and challenges associated with such methods is provided.
Collapse
Affiliation(s)
- Muhammad Sajid
- Center for Environment and Water, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia.
| | - Mazen Khaled Nazal
- Center for Environment and Water, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia
| | - Ihsanullah Ihsanullah
- Center for Environment and Water, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia
| |
Collapse
|
20
|
Manousi N, Zachariadis GA. Recent Advances in the Extraction of Polycyclic Aromatic Hydrocarbons from Environmental Samples. Molecules 2020; 25:E2182. [PMID: 32392764 PMCID: PMC7249015 DOI: 10.3390/molecules25092182] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 05/01/2020] [Accepted: 05/04/2020] [Indexed: 02/07/2023] Open
Abstract
Polycyclic aromatic hydrocarbons (PAHs) comprise a group of chemical compounds consisting of two or more fused benzene rings. PAHs exhibit hydrophobicity and low water solubility, while some of their members are toxic substances resistant to degradation. Due to their low levels in environmental matrices, a preconcentration step is usually required for their determination. Nowadays, there is a wide variety of sample preparation techniques, including micro-extraction techniques (e.g., solid-phase microextraction and liquid phase microextraction) and miniaturized extraction techniques (e.g., dispersive solid-phase extraction, magnetic solid-phase extraction, stir bar sorptive extraction, fabric phase sorptive extraction etc.). Compared to the conventional sample preparation techniques, these novel techniques show some benefits, including reduced organic solvent consumption, while they are time and cost efficient. A plethora of adsorbents, such as metal-organic frameworks, carbon-based materials and molecularly imprinted polymers, have been successfully coupled with a wide variety of extraction techniques. This review focuses on the recent advances in the extraction techniques of PAHs from environmental matrices, utilizing novel sample preparation approaches and adsorbents.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - George A. Zachariadis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
21
|
A porous composite monolith sorbent of polyaniline, multiwall carbon nanotubes and chitosan cryogel for aromatic compounds extraction. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104562] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
22
|
Moro G, Barich H, Driesen K, Felipe Montiel N, Neven L, Domingues Mendonça C, Thiruvottriyur Shanmugam S, Daems E, De Wael K. Unlocking the full power of electrochemical fingerprinting for on-site sensing applications. Anal Bioanal Chem 2020; 412:5955-5968. [DOI: 10.1007/s00216-020-02584-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 02/28/2020] [Accepted: 03/09/2020] [Indexed: 02/07/2023]
|
23
|
Azizi A, Shahhoseini F, Bottaro CS. Magnetic molecularly imprinted polymers prepared by reversible addition fragmentation chain transfer polymerization for dispersive solid phase extraction of polycyclic aromatic hydrocarbons in water. J Chromatogr A 2020; 1610:460534. [DOI: 10.1016/j.chroma.2019.460534] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2019] [Revised: 09/05/2019] [Accepted: 09/06/2019] [Indexed: 01/15/2023]
|
24
|
Electrospun core-shell nanofibers as an adsorbent for on-line micro-solid phase extraction of monohydroxy derivatives of polycyclic aromatic hydrocarbons from human urine, and their quantitation by LC-MS. Mikrochim Acta 2019; 187:57. [DOI: 10.1007/s00604-019-4007-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 11/04/2019] [Indexed: 02/07/2023]
|
25
|
Affiliation(s)
- Valérie Pichon
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation-UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS , PSL* Research University , 10 rue Vauquelin , 75005 Paris , France.,Sorbonne Université , 75005 Paris , France
| | - Nathalie Delaunay
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation-UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS , PSL* Research University , 10 rue Vauquelin , 75005 Paris , France
| | - Audrey Combès
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation-UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS , PSL* Research University , 10 rue Vauquelin , 75005 Paris , France
| |
Collapse
|
26
|
Simple and effective dispersive micro-solid phase extraction procedure for simultaneous determination of polycyclic aromatic compounds in fresh and marine waters. Talanta 2019; 204:776-791. [DOI: 10.1016/j.talanta.2019.06.061] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 06/14/2019] [Accepted: 06/15/2019] [Indexed: 11/20/2022]
|
27
|
Chemometric assisted determination of 16 PAHs in water samples by ultrasonic assisted emulsification microextraction followed by fast high-performance liquid chromatography with diode array detector. Microchem J 2019. [DOI: 10.1016/j.microc.2019.104056] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|