1
|
Chai C, Yang X, Zheng Y, Bin Heyat MB, Li Y, Yang D, Chen YH, Sawan M. Multimodal fusion of magnetoencephalography and photoacoustic imaging based on optical pump: Trends for wearable and noninvasive Brain-Computer interface. Biosens Bioelectron 2025; 278:117321. [PMID: 40049046 DOI: 10.1016/j.bios.2025.117321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2024] [Revised: 02/19/2025] [Accepted: 02/26/2025] [Indexed: 03/30/2025]
Abstract
Wearable noninvasive brain-computer interface (BCI) technologies, such as electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS), have experienced significant progress since their inception. However, these technologies have not achieved revolutionary advancements, largely because of their inherently low signal-to-noise ratio and limited penetration depth. In recent years, the application of quantum-theory-based optically pumped (OP) technologies, particularly optical pumped magnetometers (OPMs) for magnetoencephalography (MEG) and photoacoustic imaging (PAI) utilizing OP pulsed laser sources, has opened new avenues for development in noninvasive BCIs. These advanced technologies have garnered considerable attention owing to their high sensitivity in tracking neural activity and detecting blood oxygen saturation. This paper represents the first attempt to discuss and compare technologies grounded in OP theory by examining the technical advantages of OPM-MEG and PAI over traditional EEG and fNIRS. Furthermore, the paper investigates the theoretical and structural feasibility of hardware reuse in OPM-MEG and PAI applications.
Collapse
Affiliation(s)
- Chengpeng Chai
- CenBRAIN Neurotech, School of Engineering, Westlake University, 600 Dunyu Road, Xihu District, Hangzhou, Zhejiang, 310030, China; Institute of Advanced Technology, Westlake Institute for Advanced Study, 18 Shilongshan Street, Xihu District, Hangzhou, Zhejiang, 310024, China
| | - Xi Yang
- CenBRAIN Neurotech, School of Engineering, Westlake University, 600 Dunyu Road, Xihu District, Hangzhou, Zhejiang, 310030, China; Institute of Advanced Technology, Westlake Institute for Advanced Study, 18 Shilongshan Street, Xihu District, Hangzhou, Zhejiang, 310024, China
| | - Yuqiao Zheng
- CenBRAIN Neurotech, School of Engineering, Westlake University, 600 Dunyu Road, Xihu District, Hangzhou, Zhejiang, 310030, China; Institute of Advanced Technology, Westlake Institute for Advanced Study, 18 Shilongshan Street, Xihu District, Hangzhou, Zhejiang, 310024, China
| | - Md Belal Bin Heyat
- CenBRAIN Neurotech, School of Engineering, Westlake University, 600 Dunyu Road, Xihu District, Hangzhou, Zhejiang, 310030, China; Institute of Advanced Technology, Westlake Institute for Advanced Study, 18 Shilongshan Street, Xihu District, Hangzhou, Zhejiang, 310024, China
| | - Yifan Li
- Faculty of Engineering, University of Bristol, Bristol, BS8 1QU, United Kingdom
| | - Dingbo Yang
- Department of Neurosurgery, Affiliated Hangzhou First People's Hospital, Westlake University School of Medicine, Hangzhou, 310000, China; Department of Neurosurgery, Nanjing Medical University Affiliated Hangzhou Hospital, Hangzhou First People's Hospital, Hangzhou, 310000, China
| | - Yun-Hsuan Chen
- CenBRAIN Neurotech, School of Engineering, Westlake University, 600 Dunyu Road, Xihu District, Hangzhou, Zhejiang, 310030, China; Institute of Advanced Technology, Westlake Institute for Advanced Study, 18 Shilongshan Street, Xihu District, Hangzhou, Zhejiang, 310024, China.
| | - Mohamad Sawan
- CenBRAIN Neurotech, School of Engineering, Westlake University, 600 Dunyu Road, Xihu District, Hangzhou, Zhejiang, 310030, China; Institute of Advanced Technology, Westlake Institute for Advanced Study, 18 Shilongshan Street, Xihu District, Hangzhou, Zhejiang, 310024, China.
| |
Collapse
|
2
|
Xu W, Liao P, Cao M, White DJ, Lyu B, Gao JH. Facilitating cognitive neuroscience research with 80-sensor optically pumped magnetometer magnetoencephalography (OPM-MEG). Neuroimage 2025; 311:121182. [PMID: 40180002 DOI: 10.1016/j.neuroimage.2025.121182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2024] [Revised: 02/28/2025] [Accepted: 03/31/2025] [Indexed: 04/05/2025] Open
Abstract
Recent advancements in optically pumped magnetometer magnetoencephalography (OPM-MEG) make it a promising alternative to conventional SQUID-MEG systems. Nonetheless, as reported in the literature, current OPM-MEG systems are often constrained by a limited number of sampling points, which restricts their capability to match the full-head coverage offered by SQUID-MEG systems. Additionally, whether OPM-MEG can deliver results comparable to SQUID-MEG in practical cognitive neuroscience applications remains largely unexplored. In this study, we introduce a high-density, full-head coverage OPM-MEG system with 80 sensors and systematically compare the performance of OPM-MEG and SQUID-MEG, from sensor- to source-level analysis, across various classic cognitive tasks. Our results demonstrate that visual and auditory evoked fields captured using OPM-MEG align closely with those obtained from SQUID-MEG. Furthermore, steady-state visual evoked field and finger-tapping-induced beta power change recorded with OPM-MEG are accurately localized to corresponding brain regions, with activation centers highly congruent to those observed with SQUID-MEG. For resting-state recordings, the two modalities exhibit similar power distributions, functional connectomes, and microstate clusters. These findings indicate that the 80-sensor OPM-MEG system provides spatial and temporal characteristics comparable to those of traditional SQUID-MEG. Thus, our study offers empirical evidence supporting the efficacy of high-density OPM-MEG and suggests that OPM-MEG, with dense sampling capability, represents a compelling alternative to conventional SQUID-MEG, facilitating further exploration of human cognition.
Collapse
Affiliation(s)
- Wei Xu
- Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China; Changping Laboratory, Beijing, 102206, China
| | - Pan Liao
- Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China; Changping Laboratory, Beijing, 102206, China
| | - Miao Cao
- Centre for Mental Health & Brain Sciences, Swinburne University of Technology, Hawthorn, VIC, 3122, Australia
| | - David J White
- Centre for Mental Health & Brain Sciences, Swinburne University of Technology, Hawthorn, VIC, 3122, Australia
| | | | - Jia-Hong Gao
- Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China; Changping Laboratory, Beijing, 102206, China; Beijing City Key Lab for Medical Physics and Engineering, Institution of Heavy Ion Physics, School of Physics, Peking University, Beijing, 100871, China; McGovern Institute for Brain Research, Peking University, Beijing, 100871, China; National Biomedical Imaging Center, Peking University, Beijing, 100871, China.
| |
Collapse
|
3
|
Jas M, Kamataris J, Matsubara T, Dong C, Motta G, Sohrabpour A, Ahlfors SP, Hämäläinen M, Okada Y, Sundaram P. Biplanar Nulling Coil System for OPM-MEG Using Printed Circuit Boards. SENSORS (BASEL, SWITZERLAND) 2025; 25:2759. [PMID: 40363199 PMCID: PMC12074179 DOI: 10.3390/s25092759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2025] [Revised: 04/17/2025] [Accepted: 04/23/2025] [Indexed: 05/15/2025]
Abstract
Optically pumped magnetometers (OPMs) are a promising magnetoencephalography (MEG) technology for the non-invasive measurement of human electrophysiological signals. Prior work developed biplanar background field-nulling coils necessary for OPM operation, but these were expensive to produce and required tedious error-prone manual winding of >1 km of copper wire. Here, we developed a precise and reproducible manufacturing process by fabricating these coils on two-layer printed circuit boards (PCBs). Building on open-source software (bfieldtools), we developed a pipeline to determine the optimal current loops of 1.5 × 1.5 m2 biplanar nulling coils, connected these loops into a continuous conducting path across PCB layers, and printed them as pairs of 1.5 × 0.75 m2 PCBs, which were soldered and mounted on an aluminum frame. Our coils achieved efficiencies of 1.3-7.1 nT/mA, similar to or higher than previous designs. We reduced the largest background field component from 21 to 2 nT, enabling OPMs in a lightly shielded room to record somatosensory evoked fields (SEFs) comparable to SQUID-MEG. Our coil system is cheaper than commercial alternatives and is available as an open-source package opmcoils, thus enabling more affordable background field nulling for OPM-MEG and realizing its potential as an accessible sensor technology for human neuroscience.
Collapse
Affiliation(s)
- Mainak Jas
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02129, USA (T.M.); (P.S.)
- Harvard Medical School, Boston, MA 02115, USA
| | - John Kamataris
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02129, USA (T.M.); (P.S.)
| | - Teppei Matsubara
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02129, USA (T.M.); (P.S.)
- Harvard Medical School, Boston, MA 02115, USA
| | - Chunling Dong
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02129, USA (T.M.); (P.S.)
| | - Gabriel Motta
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02129, USA (T.M.); (P.S.)
| | - Abbas Sohrabpour
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02129, USA (T.M.); (P.S.)
- Harvard Medical School, Boston, MA 02115, USA
| | - Seppo P. Ahlfors
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02129, USA (T.M.); (P.S.)
- Harvard Medical School, Boston, MA 02115, USA
| | - Matti Hämäläinen
- Department of Neuroscience and Biomedical Engineering, School of Science, Aalto University, 02150 Espoo, Finland;
| | - Yoshio Okada
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02129, USA (T.M.); (P.S.)
- Harvard Medical School, Boston, MA 02115, USA
- Boston Children’s Hospital, Boston, MA 02115, USA
| | - Padmavathi Sundaram
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02129, USA (T.M.); (P.S.)
- Harvard Medical School, Boston, MA 02115, USA
| |
Collapse
|
4
|
Qi S, Song X, Jia L, Duan Z, Dai Y, Zhang J, Ning X. Investigating the effects of calibration errors on the spatial resolution of OPM-MEG beamformer imaging. Neuroimage 2025; 310:121078. [PMID: 40015614 DOI: 10.1016/j.neuroimage.2025.121078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 01/23/2025] [Accepted: 02/05/2025] [Indexed: 03/01/2025] Open
Abstract
The use of optically pumped magnetometers (OPMs) has provided a feasible, moveable and wearable alternative to superconducting detectors for magnetoencephalography (MEG) measurements. Recently, the widely used beamformer imaging technique has greatly improved spatial accuracy of MEG in the field of source reconstruction of neuroimaging. The spatial resolution of the source reconstruction using beamformer imaging technique was explored in the present study. The spatial accuracy of a beamformer reconstruction depends on accurate estimation of the data covariance matrix and lead field. In practical measurements, many sensor calibration errors including the gain error, crosstalk and angular error of the sensitive axis of OPMs due to for example, the low frequency magnetic field drift will distort the measured data as well as the forward model and thus reduce spatial resolution. The theory of OPM calibration errors was first provided based on the Bloch equations. The calibration errors are then quantified using the self-developed OPM array. And an analytical relationship between the Frobenius norm of the covariance matrix error and gain error, crosstalk was derived. The relationship between point-spread function (PSF) and the forward model error caused by the angular error of sensitive axis was analyzed. Finally, the effects of calibration errors on spatial resolution of OPM-MEG were investigated using simulations of two dipoles with orthogonal signals at the source level based on realistic head models. We find the presence of calibration errors will decrease the spatial resolution of beamformer reconstruction. And this decrease will become more severe as the signal-to-noise ratio increases.
Collapse
Affiliation(s)
- Shengjie Qi
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
| | - Xinda Song
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China; State Key Laboratory of Traditional Chinese Medicine Syndrome, Guangzhou, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, China.
| | - Le Jia
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, China
| | - Zhaoxin Duan
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
| | - Yan Dai
- Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, China
| | - Jing Zhang
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
| | - Xiaolin Ning
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China; State Key Laboratory of Traditional Chinese Medicine Syndrome, Guangzhou, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, China.
| |
Collapse
|
5
|
Bonnet M, Schwartz D, Gutteling T, Daligault S, Labyt E. A fully integrated whole-head helium OPM MEG: a performance assessment compared to cryogenic MEG. FRONTIERS IN MEDICAL TECHNOLOGY 2025; 7:1548260. [PMID: 40256680 PMCID: PMC12006120 DOI: 10.3389/fmedt.2025.1548260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2024] [Accepted: 02/28/2025] [Indexed: 04/22/2025] Open
Abstract
Magnetoencephalography (MEG) is a neuroimaging technique that measures neuronal activity at a millisecond scale. A few years ago, a new generation of MEG sensors emerged: optically pumped magnetometers (OPMs). The most common OPMs use alkali atoms as the sensing element. These alkali OPM sensors must be heated to approximately 150°C, in contrast to classical MEG sensors [superconducting quantum interference device MEG], which need to be cooled down to -269°C. This article focuses on a new kind of OPM that uses Helium-4 gas as the sensing element, which solves some disadvantages of alkali OPMs. 4He-OPM sensors operate at room temperature, with negligible heat dissipation (10 mW) and thus do not need thermal insulation. They also offer a large dynamic range (±200 nT) and frequency bandwidth (2,000 Hz). The main goal of this study is to characterize the performance of a whole-head MEG system based on 4He OPM sensors (4He OPM MEG). We first simulated different sensor configurations with three different numbers of channels and three different head sizes, from child to adult, in order to assess the signal-to-noise ratio and the source reconstruction accuracy. Experimental testing was also performed using a phantom to simulate brain magnetic activity. The simulation and experiments show equivalent detection capability and localization accuracy on both MEG systems. These results illustrate the benefit of 4He OPM sensors that operate at room temperature and are positioned closer to the scalp.
Collapse
Affiliation(s)
- Maxime Bonnet
- Lyon Neuroscience Research Center, INSERM UMRS 1028, CNRS UMR5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon, France
- MEG Department, CERMEP-Imagerie du Vivant, Lyon, France
| | - Denis Schwartz
- Lyon Neuroscience Research Center, INSERM UMRS 1028, CNRS UMR5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon, France
- MEG Department, CERMEP-Imagerie du Vivant, Lyon, France
| | - Tjerk Gutteling
- Lyon Neuroscience Research Center, INSERM UMRS 1028, CNRS UMR5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon, France
- MEG Department, CERMEP-Imagerie du Vivant, Lyon, France
| | - Sebastien Daligault
- Lyon Neuroscience Research Center, INSERM UMRS 1028, CNRS UMR5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon, France
| | | |
Collapse
|
6
|
Qi S, Song X, Jia L, Cui H, Suo Y, Long T, Wu Z, Ning X. The impact of channel density, inverse solutions, connectivity metrics and calibration errors on OPM-MEG connectivity analysis: A simulation study. Neuroimage 2025; 308:121056. [PMID: 39894237 DOI: 10.1016/j.neuroimage.2025.121056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Revised: 01/23/2025] [Accepted: 01/24/2025] [Indexed: 02/04/2025] Open
Abstract
Magnetoencephalography (MEG) systems based on optically pumped magnetometers (OPMs) have rapidly developed in the fields of brain function, health, and disease. Functional connectivity analysis related to the resting-state has gained popularity as a field of research in recent years. Several studies have attempted to use OPM-based MEG (OPM-MEG) for brain network estimation research; however, the choice of source connectivity analysis pipeline may lead to outcome variability. Several methods and related parameters must be selected carefully at each step of the analysis. Therefore, this study assessed the effect of such analytical variability on the OPM-MEG connectivity analysis by conducting simulations. Synthetic MEG data corresponding to two default mode networks (DMN) with six or ten DMN regions were generated using the Gaussian Graphical Spectral (GGS) model. Six intersensor spacings were constructed, and six inverse algorithms and six functional connectivity measures were selected to assess their impact on the network reconstruction accuracy. Three potential sources of error - errors in the sensor gain, crosstalk, and angular errors of the sensitive axis of the OPM - were also assessed. Analytical variability with regard to the tested intersensor spacings, inverse solutions, and functional connectivity measures led to high result variability. Crosstalk exerted a significant impact on the accuracy, which may lead to network reconstruction failure. The accuracy improvement caused by an increase in the sensor density may be reduced by gain and angular errors. The minimum norm estimate (MNE) and weighted minimum norm estimate (wMNE) exhibited low robustness to sensor noise and calibration errors. Hence, a calibration workflow for accurate sensor parameters, such as the gain and direction of the sensitive axis, before commencing OPM-MEG measurement and a careful choice of different method combinations play crucial roles in ensuring that OPMs yield optimal results for functional connectivity analysis. A thorough framework for analyzing brain connectivity networks was provided herein.
Collapse
Affiliation(s)
- Shengjie Qi
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
| | - Xinda Song
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China; National Key Laboratory of Traditional Chinese Medicine Symptoms, Guangzhou, China; Laboratory of Extremely Weak Magnetic Measurement, Ministry of Education, Beijing, China.
| | - Le Jia
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
| | - Hongyu Cui
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
| | - Yuchen Suo
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
| | - Tengyue Long
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
| | - Zhendong Wu
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China
| | - Xiaolin Ning
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, China; National Key Laboratory of Traditional Chinese Medicine Symptoms, Guangzhou, China; Laboratory of Extremely Weak Magnetic Measurement, Ministry of Education, Beijing, China.
| |
Collapse
|
7
|
Jas M, Kamataris J, Matsubara T, Dong C, Motta G, Sohrabpour A, Ahlfors SP, Hämäläinen M, Okada Y, Sundaram P. Biplanar nulling coil system for OPM-MEG using printed circuit boards. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2025:2025.02.19.638883. [PMID: 40027718 PMCID: PMC11870589 DOI: 10.1101/2025.02.19.638883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 03/05/2025]
Abstract
Optically pumped magnetometers (OPMs) are a promising sensor technology for non-invasive measurement of human electrophysiological signals, in particular the magnetoencephalogram (MEG). OPMs do not need cryogenic cooling and can be placed conformal to the subject's scalp, thus greatly reducing the sensor-to-source distance and improving signal sensitivity. OPMs, however, require near-zero background magnetic field to achieve linearity and minimize signal distortion. Prior work has proposed the use of biplanar field nulling coils to remove the uniform and gradient components of the background magnetic field. Biplanar coils have been expensive to construct, involving tedious error-prone manual winding of over 1000 m of copper wire. In this work, we designed and fabricated background field nulling coils (three uniform and three gradient components) on two-layer Printed Circuit Boards (PCBs). We used an open-source software (bfieldtools) to determine the current loops needed to produce the target magnetic field in a 50-cm-diameter spherical volume. We developed a software-based approach to connect the discrete current loops into a continuous conducting path traversing the two layers of the PCB. For ease of manufacture, the designed (1.5 × 1.5 m2) coils were cut along the symmetry axis and printed as pairs of 1.5 × 0.75 m2 PCBs (2 oz Cu), soldered together and mounted on a sliding aluminum frame. The efficiency of the coils (1.3 - 7.1 nT/mA) was similar or higher than previously reported in the literature. We mapped the field inside the target region after field nulling inside our single-layer shielded room and were able to reduce the largest component of the background field from 21 to 2 nT. Using our nulling coil system, we were able to operate OPMs in a lightly shielded room (background field varying from 6.5 to 108 nT in the floor-to-ceiling direction) to record somatosensory evoked fields (SEFs) comparable to those measured using SQUID-based MEG in a 3-layer shielded room. We disseminate the software and hardware as an open-source package opmcoils. This work will facilitate access to more affordable field nulling coils for OPM-MEG and help to realize the potential of OPM-MEG as an accessible sensor technology for use in human neuroscience.
Collapse
Affiliation(s)
- Mainak Jas
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
- Harvard Medical School, Boston, USA
| | - John Kamataris
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
| | - Teppei Matsubara
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
- Harvard Medical School, Boston, USA
| | - Chunling Dong
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
| | - Gabriel Motta
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
| | - Abbas Sohrabpour
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
- Harvard Medical School, Boston, USA
| | - Seppo P. Ahlfors
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
- Harvard Medical School, Boston, USA
| | - Matti Hämäläinen
- Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
| | - Yoshio Okada
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
- Harvard Medical School, Boston, USA
- Boston Children’s Hospital, Boston, USA
| | - Padmavathi Sundaram
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA
- Harvard Medical School, Boston, USA
| |
Collapse
|
8
|
Wang T, Lee W, Limes M, Kornack T, Foley E, Romalis M. Pulsed vector atomic magnetometer using an alternating fast-rotating field. Nat Commun 2025; 16:1374. [PMID: 39910092 PMCID: PMC11799169 DOI: 10.1038/s41467-025-56668-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Accepted: 01/27/2025] [Indexed: 02/07/2025] Open
Abstract
We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 fT / Hz (0.7 parts per billion) and angular resolutions of 6 nrad / Hz at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.
Collapse
Affiliation(s)
- Tao Wang
- Department of Physics, Princeton University, Princeton, NJ, USA.
- A*STAR Quantum Innovation Centre (Q.InC), Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, 08-03, Singapore, Republic of Singapore.
| | - Wonjae Lee
- Department of Physics, Princeton University, Princeton, NJ, USA
- Department of Physics, Harvard University, Cambridge, MA, USA
| | - Mark Limes
- Twinleaf LLC, 300 Deer Creek Dr., Plainsboro, New Jersey, USA
- Virginia Tech, Blacksburg, Virginia, USA
| | - Thomas Kornack
- Twinleaf LLC, 300 Deer Creek Dr., Plainsboro, New Jersey, USA
| | - Elizabeth Foley
- Twinleaf LLC, 300 Deer Creek Dr., Plainsboro, New Jersey, USA
| | - Michael Romalis
- Department of Physics, Princeton University, Princeton, NJ, USA.
| |
Collapse
|
9
|
Wang F, Ma Y, Gao T, Tao Y, Wang R, Zhao R, Cao F, Gao Y, Ning X. Repairbads: An automatic and adaptive method to repair bad channels and segments for OPM-MEG. Neuroimage 2025; 306:120996. [PMID: 39778818 DOI: 10.1016/j.neuroimage.2024.120996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Revised: 11/11/2024] [Accepted: 12/31/2024] [Indexed: 01/11/2025] Open
Abstract
The optically pumped magnetometer (OPM) based magnetoencephalography (MEG) system offers advantages such as flexible layout and wearability. However, the position instability or jitter of OPM sensors can result in bad channels and segments, which significantly impede subsequent preprocessing and analysis. Most common methods directly reject or interpolate to repair these bad channels and segments. Direct rejection leads to data loss, and when the number of sensors is limited, interpolation using neighboring sensors can cause significant signal distortion and cannot repair bad segments present in all channels. Therefore, most existing methods are unsuitable for OPM-MEG systems with fewer channels. We introduce an automatic bad segments and bad channels repair method for OPM-MEG, called Repairbads. This method aims to repair all bad data and reduce signal distortion, especially capable of automatically repairing bad segments present in all channels simultaneously. Repairbads employs Riemannian Potato combined with joint decorrelation to project out artifact components, achieving automatic bad segment repair. Then, an adaptive algorithm is used to segment the signal into relatively stable noise data chunks, and the source-estimate-utilizing noise-discarding algorithm is applied to each chunk to achieve automatic bad channel repair. We compared the performance of Repairbads with the Autoreject method on both simulated and real auditory evoked data, using five evaluation metrics for quantitative assessment. The results demonstrate that Repairbads consistently outperforms across all five metrics. In both simulated and real OPM-MEG data, Repairbads shows better performance than current state-of-the-art methods, reliably repairing bad data with minimal distortion. The automation of this method significantly reduces the burden of manual inspection, promoting the automated processing and clinical application of OPM-MEG.
Collapse
Affiliation(s)
- Fulong Wang
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Yujie Ma
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Tianyu Gao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Yue Tao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Ruonan Wang
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Ruochen Zhao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Fuzhi Cao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China; School of Engineering Medicine, Beihang University, Beijing, 100191, China.
| | - Yang Gao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Xiaolin Ning
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China; State Key Laboratory of Traditional Chinese Medicine Syndrome/Health Construction Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China; Hefei National Laboratory, Hefei, 230088, China.
| |
Collapse
|
10
|
Holmes N, Leggett J, Hill RM, Rier L, Boto E, Schofield H, Hayward T, Dawson E, Woolger D, Shah V, Taulu S, Brookes MJ, Bowtell R. Wearable Magnetoencephalography in a Lightly Shielded Environment. IEEE Trans Biomed Eng 2025; 72:609-618. [PMID: 39302788 PMCID: PMC11933739 DOI: 10.1109/tbme.2024.3465654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
Wearable magnetoencephalography based on optically pumped magnetometers (OPM-MEG) offers non-invasive and high-fidelity measurement of human brain electrophysiology. The flexibility of OPM-MEG also means it can be deployed in participants of all ages and permits scanning during movement. However, the magnetic fields generated by neuronal currents - which form the basis of the OPM-MEG signal - are much smaller than environmental fields, and this means measurements are highly sensitive to interference. Further, OPMs have a low dynamic range, and should be operated in near-zero background field. Scanners must therefore be housed in specialised magnetically shielded rooms (MSRs), formed from multiple layers of shielding material. The MSR is a critical component, and current OPM-optimised shields are large (>3 m in height), heavy (>10,000 kg) and expensive (with up to 5 layers of material). This restricts the uptake of OPM-MEG technology. Here, we show that the application of the Maxwell filtering techniques signal space separation (SSS) and its spatiotemporal extension (tSSS) to OPM-MEG data can isolate small signals of interest measured in the presence of large interference. We compare phantom recordings and MEG data from a participant performing a motor task in a state-of-the-art 5-layer MSR, to similar data collected in a lightly shielded room: application of tSSS to data recorded in the lightly shielded room allowed accurate localisation of a dipole source in the phantom and neuronal sources in the brain. Our results point to future deployment of OPM-MEG in lighter, cheaper and easier-to-site MSRs which could catalyse widespread adoption of the technology.
Collapse
|
11
|
Wang F, Cao F, Ma Y, Zhao R, Wang R, An N, Xiang M, Wang D, Ning X. Extended homogeneous field correction method based on oblique projection in OPM-MEG. Neuroimage 2025; 306:120991. [PMID: 39756668 DOI: 10.1016/j.neuroimage.2024.120991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2024] [Revised: 11/11/2024] [Accepted: 12/30/2024] [Indexed: 01/07/2025] Open
Abstract
Optically pumped magnetometer-based magnetoencephalography (OPM-MEG) is an novel non-invasive functional imaging technique that features more flexible sensor configurations and wearability; however, this also increases the requirement for environmental noise suppression. Subspace projection algorithms are widely used in MEG to suppress noise. However, in OPM-MEG systems with a limited number of channels, subspace projection methods that rely on spatial oversampling exhibit reduced performance. The homogeneous field correction (HFC) method resolves this problem by constructing a low-rank spatial model; however, it cannot address complex non-homogeneous noise. The spatiotemporal extended homogeneous field correction (teHFC) method uses multiple orthogonal projections to suppress disturbances. However, the signal and noise subspace are not completely orthogonal, limiting enhancement in the capabilities of the teHFC. Therefore, we propose an extended homogeneous field correction method based on oblique projection (opHFC), which overcomes the issue of non-orthogonality between the signal and noise subspace, enhancing the ability to suppress complex interferences. The opHFC constructs an oblique projection operator that divides the signals into internal and external components, eliminating complex interferences through temporal extension. We compared the opHFC with four benchmark methods by simulations and auditory and somatosensory evoked OPM-MEG experiments. The results demonstrate that opHFC provides superior noise suppression with minimal distortion, enhancing the signal quality at the sensor and source levels. Our method offers a novel approach to reducing interference in OPM-MEG systems, expanding their application scenarios, and providing high-quality signals for scientific research and clinical applications based on OPM-MEG.
Collapse
Affiliation(s)
- Fulong Wang
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Fuzhi Cao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China; School of Engineering Medicine, Beihang University, Beijing, 100191, China.
| | - Yujie Ma
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Ruochen Zhao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Ruonan Wang
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Nan An
- Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China.
| | - Min Xiang
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China; State Key Laboratory of Traditional Chinese Medicine Syndrome/Health Construction Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China; Hefei National Laboratory, Hefei, 230088, China.
| | - Dawei Wang
- National Medicine-Engineering Interdisciplinary Industry-Education Integration Innovation Platform, Shandong University, Jinan, 250014, China; Shandong Key Laboratory: Magnetic Field-free Medicine & Functional Imaging, Qilu Hospital of Shandong University, Jinan, 250014, China; Research Institute of Shandong University: Magnetic Field-free Medicine & Functional Imaging, Shandong University, Jinan, 250014, China.
| | - Xiaolin Ning
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China; State Key Laboratory of Traditional Chinese Medicine Syndrome/Health Construction Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China; Hefei National Laboratory, Hefei, 230088, China.
| |
Collapse
|
12
|
Bezsudnova Y, Quinn AJ, Jensen O. Optimizing magnetometers arrays and analysis pipelines for multivariate pattern analysis. J Neurosci Methods 2024; 412:110279. [PMID: 39265820 DOI: 10.1016/j.jneumeth.2024.110279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 08/12/2024] [Accepted: 09/09/2024] [Indexed: 09/14/2024]
Abstract
BACKGROUND Multivariate pattern analysis (MVPA) has proven an excellent tool in cognitive neuroscience. It also holds a strong promise when applied to optically-pumped magnetometer-based magnetoencephalography. NEW METHOD To optimize OPM-MEG systems for MVPA experiments this study examines data from a conventional MEG magnetometer array, focusing on appropriate noise reduction techniques for magnetometers. We determined the least required number of sensors needed for robust MVPA for image categorization experiments. RESULTS We found that the use of signal space separation (SSS) without a proper regularization significantly lowered the classification accuracy considering a sub-array of 102 magnetometers or a sub-array of 204 gradiometers. We also found that classification accuracy did not improve when going beyond 30 sensors irrespective of whether SSS has been applied. COMPARISON WITH EXISTING METHODS The power spectra of data filtered with SSS has a substantially higher noise floor that data cleaned with SSP or HFC. Consequently, MVPA decoding results obtained from the SSS-filtered data are significantly lower compared to all other methods employed. CONCLUSIONS When designing MEG system based on SQUID magnetometers optimized for multivariate analysis for image categorization experiments, about 30 magnetometers are sufficient. We advise against applying SSS filters without a proper regularization to data from MEG and OPM systems prior to performing MVPA as this method, albeit reducing low-frequency external noise contributions, also introduces an increase in broadband noise. We recommend employing noise reduction techniques that either decrease or maintain the noise floor of the data like signal-space projection, homogeneous field correction and gradient noise reduction.
Collapse
Affiliation(s)
- Yulia Bezsudnova
- Centre for Human Brain Health, School of Psychology, University of Birmingham, Birmingham, UK.
| | - Andrew J Quinn
- Centre for Human Brain Health, School of Psychology, University of Birmingham, Birmingham, UK
| | - Ole Jensen
- Centre for Human Brain Health, School of Psychology, University of Birmingham, Birmingham, UK
| |
Collapse
|
13
|
Govindan RB, Loparo KA. Bedside monitoring tools and advanced signal processing approaches to monitor critically-ill infants. Semin Fetal Neonatal Med 2024; 29:101544. [PMID: 39467727 DOI: 10.1016/j.siny.2024.101544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/30/2024]
Abstract
There is a substantial body of literature that supports neonatal monitoring and signal analysis of the collected data to provide valuable insights for improving patient clinical care and to inform new research studies. This comprehensive monitoring approach extends beyond the collection of conventional vital signs to include the acquisition of continuous waveform data from patient monitors and other bedside medical devices. This paper discusses the necessary infrastructure for waveform retrieval from bedside monitors, and explores options provided by leading healthcare companies, third-party vendors or academic research teams to implement scalable monitoring systems across entire critical care units. Additionally, we discuss the application of advanced signal processing that transcend traditional statistics, including heart rate variability in both the time- and frequency-domains, spectral analysis of EEG, and cerebral pressure autoregulation. The infrastructures and signal processing techniques outlined here are indispensable tools for intensivists, empowering them to enhance care for critically ill infants. In addition, we briefly address the emergence of advanced tools for fetal monitoring.
Collapse
Affiliation(s)
- R B Govindan
- The Zickler Family Prenatal Pediatrics Institute, Children's National Hospital, Washington, DC, USA; Department of Pediatrics, The George Washington University School of Medicine, Washington, DC, USA; The Developing Brain Institute, Children's National Hospital, Washington, DC, USA.
| | - Kenneth A Loparo
- Institute for Smart, Secure and Connected Systems: ISSACS, Case Western Reserve University, Cleveland, OH, USA.
| |
Collapse
|
14
|
Spedden ME, O’Neill GC, Tierney TM, West TO, Schmidt M, Mellor S, Farmer SF, Bestmann S, Barnes GR. Towards non-invasive imaging through spinal-cord generated magnetic fields. FRONTIERS IN MEDICAL TECHNOLOGY 2024; 6:1470970. [PMID: 39445170 PMCID: PMC11496111 DOI: 10.3389/fmedt.2024.1470970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Accepted: 09/20/2024] [Indexed: 10/25/2024] Open
Abstract
Non-invasive imaging of the human spinal cord is a vital tool for understanding the mechanisms underlying its functions in both healthy and pathological conditions. However, non-invasive imaging presents a significant methodological challenge because the spinal cord is difficult to access with conventional neurophysiological approaches, due to its proximity to other organs and muscles, as well as the physiological movements caused by respiration, heartbeats, and cerebrospinal fluid (CSF) flow. Here, we discuss the present state and future directions of spinal cord imaging, with a focus on the estimation of current flow through magnetic field measurements. We discuss existing cryogenic (superconducting) and non-cryogenic (optically-pumped magnetometer-based, OPM) systems, and highlight their strengths and limitations for studying human spinal cord function. While significant challenges remain, particularly in source imaging and interference rejection, magnetic field-based neuroimaging offers a novel avenue for advancing research in various areas. These include sensorimotor processing, cortico-spinal interplay, brain and spinal cord plasticity during learning and recovery from injury, and pain perception. Additionally, this technology holds promise for diagnosing and optimizing the treatment of spinal cord disorders.
Collapse
Affiliation(s)
- Meaghan E. Spedden
- Department of Imaging Neuroscience, Institute of Neurology, University College London, London, United Kingdom
| | - George C. O’Neill
- Department of Neuroscience, Physiology and Pharmacology, University College London, London, United Kingdom
| | - Tim M. Tierney
- Department of Imaging Neuroscience, Institute of Neurology, University College London, London, United Kingdom
| | - Timothy O. West
- Department of Imaging Neuroscience, Institute of Neurology, University College London, London, United Kingdom
- Department of Biomedical Engineering, Imperial College London, London, United Kingdom
| | - Maike Schmidt
- Department of Imaging Neuroscience, Institute of Neurology, University College London, London, United Kingdom
| | - Stephanie Mellor
- Department of Imaging Neuroscience, Institute of Neurology, University College London, London, United Kingdom
| | - Simon F. Farmer
- Department for Clinical and Movement Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom
- Department of Clinical Neurology, The National Hospital for Neurology and Neurosurgery, London, United Kingdom
| | - Sven Bestmann
- Department of Imaging Neuroscience, Institute of Neurology, University College London, London, United Kingdom
- Department for Clinical and Movement Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom
| | - Gareth R. Barnes
- Department of Imaging Neuroscience, Institute of Neurology, University College London, London, United Kingdom
| |
Collapse
|
15
|
Schofield H, Hill RM, Feys O, Holmes N, Osborne J, Doyle C, Bobela D, Corvilain P, Wens V, Rier L, Bowtell R, Ferez M, Mullinger KJ, Coleman S, Rhodes N, Rea M, Tanner Z, Boto E, de Tiège X, Shah V, Brookes MJ. A novel, robust, and portable platform for magnetoencephalography using optically-pumped magnetometers. IMAGING NEUROSCIENCE (CAMBRIDGE, MASS.) 2024; 2:1-22. [PMID: 39502465 PMCID: PMC11533384 DOI: 10.1162/imag_a_00283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 06/28/2024] [Accepted: 07/29/2024] [Indexed: 11/08/2024]
Abstract
Magnetoencephalography (MEG) measures brain function via assessment of magnetic fields generated by neural currents. Conventional MEG uses superconducting sensors, which place significant limitations on performance, practicality, and deployment; however, the field has been revolutionised in recent years by the introduction of optically-pumped magnetometers (OPMs). OPMs enable measurement of the MEG signal without cryogenics, and consequently the conception of "OPM-MEG" systems which ostensibly allow increased sensitivity and resolution, lifespan compliance, free subject movement, and lower cost. However, OPM-MEG is in its infancy with existing limitations on both sensor and system design. Here, we report a new OPM-MEG design with miniaturised and integrated electronic control, a high level of portability, and improved sensor dynamic range. We show that this system produces equivalent measures compared with an established OPM-MEG instrument; specifically, when measuring task-induced beta-band, gamma-band, and evoked neuro-electrical responses, source localisations from the two systems were comparable and temporal correlation of measured brain responses was >0.7 at the individual level and >0.9 for groups. Using an electromagnetic phantom, we demonstrate improved dynamic range by running the system in background fields up to 8 nT. We show that the system is effective in gathering data during free movement (including a sitting-to-standing paradigm) and that it is compatible with simultaneous electroencephalography (EEG). Finally, we demonstrate portability by moving the system between two laboratories. Overall, our new system is shown to be a significant step forward for OPM-MEG and offers an attractive platform for next generation functional medical imaging.
Collapse
Affiliation(s)
- Holly Schofield
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
- Cerca Magnetics Limited, Nottingham, United Kingdom
| | - Ryan M. Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
- Cerca Magnetics Limited, Nottingham, United Kingdom
| | - Odile Feys
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
- Department of Neurology, Hôpital Erasme, Hôpital Universitaire de Bruxelles, Université libre de Bruxelles, Brussels, Belgium
| | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
- Cerca Magnetics Limited, Nottingham, United Kingdom
| | | | - Cody Doyle
- QuSpin Inc., Louisville, CO, United States
| | | | - Pierre Corvilain
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
| | - Vincent Wens
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
- Department of Translational Neuroimaging, Hôpital Erasme, Hôpital Universitaire de Bruxelles, Université libre de Bruxelles, Brussels, Belgium
| | - Lukas Rier
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
| | - Maxime Ferez
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
| | - Karen J. Mullinger
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
- Centre for Human Brain Health, School of Psychology, University of Birmingham, Birmingham, United Kingdom
| | - Sebastian Coleman
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
| | - Natalie Rhodes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
| | - Molly Rea
- Cerca Magnetics Limited, Nottingham, United Kingdom
| | - Zoe Tanner
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
- Cerca Magnetics Limited, Nottingham, United Kingdom
| | - Elena Boto
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
- Cerca Magnetics Limited, Nottingham, United Kingdom
| | - Xavier de Tiège
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
- Department of Translational Neuroimaging, Hôpital Erasme, Hôpital Universitaire de Bruxelles, Université libre de Bruxelles, Brussels, Belgium
| | | | - Matthew J. Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
- Cerca Magnetics Limited, Nottingham, United Kingdom
| |
Collapse
|
16
|
Brickwedde M, Anders P, Kühn AA, Lofredi R, Holtkamp M, Kaindl AM, Grent-'t-Jong T, Krüger P, Sander T, Uhlhaas PJ. Applications of OPM-MEG for translational neuroscience: a perspective. Transl Psychiatry 2024; 14:341. [PMID: 39181883 PMCID: PMC11344782 DOI: 10.1038/s41398-024-03047-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 06/25/2024] [Accepted: 08/01/2024] [Indexed: 08/27/2024] Open
Abstract
Magnetoencephalography (MEG) allows the non-invasive measurement of brain activity at millisecond precision combined with localization of the underlying generators. So far, MEG-systems consisted of superconducting quantum interference devices (SQUIDS), which suffer from several limitations. Recent technological advances, however, have enabled the development of novel MEG-systems based on optically pumped magnetometers (OPMs), offering several advantages over conventional SQUID-MEG systems. Considering potential improvements in the measurement of neuronal signals as well as reduced operating costs, the application of OPM-MEG systems for clinical neuroscience and diagnostic settings is highly promising. Here we provide an overview of the current state-of-the art of OPM-MEG and its unique potential for translational neuroscience. First, we discuss the technological features of OPMs and benchmark OPM-MEG against SQUID-MEG and electroencephalography (EEG), followed by a summary of pioneering studies of OPMs in healthy populations. Key applications of OPM-MEG for the investigation of psychiatric and neurological conditions are then reviewed. Specifically, we suggest novel applications of OPM-MEG for the identification of biomarkers and circuit deficits in schizophrenia, dementias, movement disorders, epilepsy, and neurodevelopmental syndromes (autism spectrum disorder and attention deficit hyperactivity disorder). Finally, we give an outlook of OPM-MEG for translational neuroscience with a focus on remaining methodological and technical challenges.
Collapse
Affiliation(s)
- Marion Brickwedde
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Berlin Institute of Health, Department of Child and Adolescent Psychiatry, 13353, Berlin, Germany.
- Physikalisch-Technische Bundesanstalt, Berlin, Germany.
| | - Paul Anders
- Physikalisch-Technische Bundesanstalt, Berlin, Germany
| | - Andrea A Kühn
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Berlin Institute of Health, Sektion für Bewegungsstörungen und Neuromodulation, Klinik für Neurologie und Experimentelle Neurologie, 10117, Berlin, Germany
- Bernstein Center for Computational Neuroscience, Humboldt-Universität, Berlin, Germany
- NeuroCure, Exzellenzcluster, Charité-Universitätsmedizin Berlin, Berlin, Germany
- DZNE, German center for neurodegenerative diseases, Berlin, Germany
- Berlin School of Mind and Brain, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Roxanne Lofredi
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Berlin Institute of Health, Sektion für Bewegungsstörungen und Neuromodulation, Klinik für Neurologie und Experimentelle Neurologie, 10117, Berlin, Germany
- Berlin Institute of Health, Berlin, Germany
| | - Martin Holtkamp
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Berlin Institute of Health, Department of Neurology, Epilepsy-Center Berlin-Brandenburg, 10117, Berlin, Germany
| | - Angela M Kaindl
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Berlin Institute of Health, Department of Pediatric Neurology, 13353, Berlin, Germany
- Charité- Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Berlin Institute of Health, Center for Chronically Sick Children, 13353, Berlin, Germany
- Charité- Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Berlin Institute of Health, Institute of Cell Biology and Neurobiology, 10117, Berlin, Germany
| | - Tineke Grent-'t-Jong
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Berlin Institute of Health, Department of Child and Adolescent Psychiatry, 13353, Berlin, Germany
- Institute for Neuroscience and Psychology, Glasgow University, Scotland, United Kingdom
| | - Peter Krüger
- Physikalisch-Technische Bundesanstalt, Berlin, Germany
| | | | - Peter J Uhlhaas
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Berlin Institute of Health, Department of Child and Adolescent Psychiatry, 13353, Berlin, Germany
- Institute for Neuroscience and Psychology, Glasgow University, Scotland, United Kingdom
| |
Collapse
|
17
|
Rier L, Rhodes N, Pakenham DO, Boto E, Holmes N, Hill RM, Reina Rivero G, Shah V, Doyle C, Osborne J, Bowtell RW, Taylor M, Brookes MJ. Tracking the neurodevelopmental trajectory of beta band oscillations with optically pumped magnetometer-based magnetoencephalography. eLife 2024; 13:RP94561. [PMID: 38831699 PMCID: PMC11149934 DOI: 10.7554/elife.94561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2024] Open
Abstract
Neural oscillations mediate the coordination of activity within and between brain networks, supporting cognition and behaviour. How these processes develop throughout childhood is not only an important neuroscientific question but could also shed light on the mechanisms underlying neurological and psychiatric disorders. However, measuring the neurodevelopmental trajectory of oscillations has been hampered by confounds from instrumentation. In this paper, we investigate the suitability of a disruptive new imaging platform - optically pumped magnetometer-based magnetoencephalography (OPM-MEG) - to study oscillations during brain development. We show how a unique 192-channel OPM-MEG device, which is adaptable to head size and robust to participant movement, can be used to collect high-fidelity electrophysiological data in individuals aged between 2 and 34 years. Data were collected during a somatosensory task, and we measured both stimulus-induced modulation of beta oscillations in sensory cortex, and whole-brain connectivity, showing that both modulate significantly with age. Moreover, we show that pan-spectral bursts of electrophysiological activity drive task-induced beta modulation, and that their probability of occurrence and spectral content change with age. Our results offer new insights into the developmental trajectory of beta oscillations and provide clear evidence that OPM-MEG is an ideal platform for studying electrophysiology in neurodevelopment.
Collapse
Affiliation(s)
- Lukas Rier
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University ParkNottinghamUnited Kingdom
| | - Natalie Rhodes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University ParkNottinghamUnited Kingdom
- Diagnostic Imaging, The Hospital for Sick ChildrenTorontoCanada
| | - Daisie O Pakenham
- Clinical Neurophysiology, Nottingham University Hospitals NHS Trust, Queens Medical CentreNottinghamUnited States
| | - Elena Boto
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University ParkNottinghamUnited Kingdom
- Cerca Magnetics Limited, 7-8 Castlebridge Office Village, Kirtley DriveNottinghamUnited Kingdom
| | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University ParkNottinghamUnited Kingdom
- Cerca Magnetics Limited, 7-8 Castlebridge Office Village, Kirtley DriveNottinghamUnited Kingdom
| | - Ryan M Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University ParkNottinghamUnited Kingdom
- Cerca Magnetics Limited, 7-8 Castlebridge Office Village, Kirtley DriveNottinghamUnited Kingdom
| | - Gonzalo Reina Rivero
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University ParkNottinghamUnited Kingdom
| | | | | | | | - Richard W Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University ParkNottinghamUnited Kingdom
| | - Margot Taylor
- Diagnostic Imaging, The Hospital for Sick ChildrenTorontoCanada
| | - Matthew J Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University ParkNottinghamUnited Kingdom
- Cerca Magnetics Limited, 7-8 Castlebridge Office Village, Kirtley DriveNottinghamUnited Kingdom
| |
Collapse
|
18
|
Mardell LC, Spedden ME, O'Neill GC, Tierney TM, Timms RC, Zich C, Barnes GR, Bestmann S. Concurrent spinal and brain imaging with optically pumped magnetometers. J Neurosci Methods 2024; 406:110131. [PMID: 38583588 DOI: 10.1016/j.jneumeth.2024.110131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 03/11/2024] [Accepted: 04/03/2024] [Indexed: 04/09/2024]
Abstract
BACKGROUND The spinal cord and its interactions with the brain are fundamental for movement control and somatosensation. However, brain and spinal electrophysiology in humans have largely been treated as distinct enterprises, in part due to the relative inaccessibility of the spinal cord. Consequently, there is a dearth of knowledge on human spinal electrophysiology, including the multiple pathologies that affect the spinal cord as well as the brain. NEW METHOD Here we exploit recent advances in the development of wearable optically pumped magnetometers (OPMs) which can be flexibly arranged to provide coverage of both the spinal cord and the brain in relatively unconstrained environments. This system for magnetospinoencephalography (MSEG) measures both spinal and cortical signals simultaneously by employing custom-made scanning casts. RESULTS We evidence the utility of such a system by recording spinal and cortical evoked responses to median nerve stimulation at the wrist. MSEG revealed early (10 - 15 ms) and late (>20 ms) responses at the spinal cord, in addition to typical cortical evoked responses (i.e., N20). COMPARISON WITH EXISTING METHODS Early spinal evoked responses detected were in line with conventional somatosensory evoked potential recordings. CONCLUSION This MSEG system demonstrates the novel ability for concurrent non-invasive millisecond imaging of brain and spinal cord.
Collapse
Affiliation(s)
- Lydia C Mardell
- Department of Clinical and Movement Neurosciences, UCL Queen Square Institute of Neurology, University College London, WC1N 3BG, UK.
| | - Meaghan E Spedden
- Wellcome Centre for Human Neuroimaging, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, WC1N 3AR, UK
| | - George C O'Neill
- Wellcome Centre for Human Neuroimaging, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, WC1N 3AR, UK
| | - Tim M Tierney
- Wellcome Centre for Human Neuroimaging, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, WC1N 3AR, UK
| | - Ryan C Timms
- Wellcome Centre for Human Neuroimaging, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, WC1N 3AR, UK
| | - Catharina Zich
- Department of Clinical and Movement Neurosciences, UCL Queen Square Institute of Neurology, University College London, WC1N 3BG, UK
| | - Gareth R Barnes
- Wellcome Centre for Human Neuroimaging, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, WC1N 3AR, UK
| | - Sven Bestmann
- Department of Clinical and Movement Neurosciences, UCL Queen Square Institute of Neurology, University College London, WC1N 3BG, UK; Wellcome Centre for Human Neuroimaging, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, WC1N 3AR, UK
| |
Collapse
|
19
|
Ji D, Xiao X, Wu J, He X, Zhang G, Guo R, Liu M, Xu M, Lin Q, Jung TP, Ming D. A user-friendly visual brain-computer interface based on high-frequency steady-state visual evoked fields recorded by OPM-MEG. J Neural Eng 2024; 21:036024. [PMID: 38812288 DOI: 10.1088/1741-2552/ad44d8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 04/29/2024] [Indexed: 05/31/2024]
Abstract
Objective. Magnetoencephalography (MEG) shares a comparable time resolution with electroencephalography. However, MEG excels in spatial resolution, enabling it to capture even the subtlest and weakest brain signals for brain-computer interfaces (BCIs). Leveraging MEG's capabilities, specifically with optically pumped magnetometers (OPM-MEG), proves to be a promising avenue for advancing MEG-BCIs, owing to its exceptional sensitivity and portability. This study harnesses the power of high-frequency steady-state visual evoked fields (SSVEFs) to build an MEG-BCI system that is flickering-imperceptible, user-friendly, and highly accurate.Approach.We have constructed a nine-command BCI that operates on high-frequency SSVEF (58-62 Hz with a 0.5 Hz interval) stimulation. We achieved this by placing the light source inside and outside the magnetic shielding room, ensuring compliance with non-magnetic and visual stimulus presentation requirements. Five participants took part in offline experiments, during which we collected six-channel multi-dimensional MEG signals along both the vertical (Z-axis) and tangential (Y-axis) components. Our approach leveraged the ensemble task-related component analysis algorithm for SSVEF identification and system performance evaluation.Main Results.The offline average accuracy of our proposed system reached an impressive 92.98% when considering multi-dimensional conjoint analysis using data from both theZandYaxes. Our method achieved a theoretical average information transfer rate (ITR) of 58.36 bits min-1with a data length of 0.7 s, and the highest individual ITR reached an impressive 63.75 bits min-1.Significance.This study marks the first exploration of high-frequency SSVEF-BCI based on OPM-MEG. These results underscore the potential and feasibility of MEG in detecting subtle brain signals, offering both theoretical insights and practical value in advancing the development and application of MEG in BCI systems.
Collapse
Affiliation(s)
- Dengpei Ji
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, People's Republic of China
- Haihe Laboratory of Brain-computer Interaction and Human-machine Integration, Tianjin, People's Republic of China
| | - Xiaolin Xiao
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, People's Republic of China
- Haihe Laboratory of Brain-computer Interaction and Human-machine Integration, Tianjin, People's Republic of China
| | - Jieyu Wu
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, People's Republic of China
- Haihe Laboratory of Brain-computer Interaction and Human-machine Integration, Tianjin, People's Republic of China
| | - Xiang He
- College of Science, Zhejiang University of Technology, Hangzhou, Zhejiang, People's Republic of China
| | - Guiying Zhang
- College of Science, Zhejiang University of Technology, Hangzhou, Zhejiang, People's Republic of China
| | - Ruihan Guo
- College of Science, Zhejiang University of Technology, Hangzhou, Zhejiang, People's Republic of China
| | - Miao Liu
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, People's Republic of China
- Haihe Laboratory of Brain-computer Interaction and Human-machine Integration, Tianjin, People's Republic of China
| | - Minpeng Xu
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, People's Republic of China
- Haihe Laboratory of Brain-computer Interaction and Human-machine Integration, Tianjin, People's Republic of China
| | - Qiang Lin
- College of Science, Zhejiang University of Technology, Hangzhou, Zhejiang, People's Republic of China
| | - Tzyy-Ping Jung
- Swartz Center for Computational Neuroscience Institute for Neural Computation, University of California San Diego, San Diego, CA, United States of America
| | - Dong Ming
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, People's Republic of China
- Haihe Laboratory of Brain-computer Interaction and Human-machine Integration, Tianjin, People's Republic of China
| |
Collapse
|
20
|
Zhang J, Chen T, Wei C, Ou Z, Yue H, Liu Y. Single-beam three-axis SERF atomic magnetometer based on coordinate system rotation. OPTICS EXPRESS 2024; 32:17165-17172. [PMID: 38858906 DOI: 10.1364/oe.524308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Accepted: 04/11/2024] [Indexed: 06/12/2024]
Abstract
We propose what we believe to be a new single-beam three-axis spin exchange relaxation free (SERF) vector atomic magnetometer scheme based on coordinate system deflection. A theoretical model for the system response under arbitrary angle deflection was established for the first time, and the system response at different angles was simulated and analyzed. The simulation results show that the system response increases in the direction of the non-sensitive axis and decreases in the direction of the sensitive axis as the deflection angle increases, and the two responses tend to be the same when the angle is deflected to 45-degrees. Experimental measurements were carried out at a deflection angle of 45-degrees and the results showed that the sensitivity of the magnetometer was 55fT/Hz1/2 in the x1-axis, 38fT/Hz1/2 in the y1-axis and 60fT/Hz1/2 in the z1-axis. This single-beam magnetometer can be used to construct a miniaturized and low-cost weak magnetic sensor, which is expected to be used for vector measurement of biomagnetism.
Collapse
|
21
|
Turk-Browne NB, Aslin RN. Infant neuroscience: how to measure brain activity in the youngest minds. Trends Neurosci 2024; 47:338-354. [PMID: 38570212 PMCID: PMC11956833 DOI: 10.1016/j.tins.2024.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 01/08/2024] [Accepted: 02/09/2024] [Indexed: 04/05/2024]
Abstract
The functional properties of the infant brain are poorly understood. Recent advances in cognitive neuroscience are opening new avenues for measuring brain activity in human infants. These include novel uses of existing technologies such as electroencephalography (EEG) and magnetoencephalography (MEG), the availability of newer technologies including functional near-infrared spectroscopy (fNIRS) and optically pumped magnetometry (OPM), and innovative applications of functional magnetic resonance imaging (fMRI) in awake infants during cognitive tasks. In this review article we catalog these available non-invasive methods, discuss the challenges and opportunities encountered when applying them to human infants, and highlight the potential they may ultimately hold for advancing our understanding of the youngest minds.
Collapse
Affiliation(s)
- Nicholas B Turk-Browne
- Department of Psychology, Yale University, New Haven, CT 06520, USA; Wu Tsai Institute, Yale University, New Haven, CT 06510, USA.
| | - Richard N Aslin
- Department of Psychology, Yale University, New Haven, CT 06520, USA; Child Study Center, Yale School of Medicine, New Haven, CT 06520, USA
| |
Collapse
|
22
|
Su S, Xu Z, He X, Zhang G, Wu H, Gao Y, Ma Y, Yin C, Ruan Y, Li K, Lin Q. Vector magnetocardiography using compact optically-pumped magnetometers. Heliyon 2024; 10:e29092. [PMID: 38601529 PMCID: PMC11004653 DOI: 10.1016/j.heliyon.2024.e29092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 03/29/2024] [Accepted: 03/31/2024] [Indexed: 04/12/2024] Open
Abstract
Optically pumped magnetometers can provide functionality for bio-magnetic field detection and mapping. This has attracted widespread attention from researchers in the biomedical science field. Magnetocardiography has been proven to be an effective method for examining heart disease. Notably, vector magnetocardiography obtains more spatial information than the conventional method by only taking a component that is perpendicular to the chest surface. In this work, a spin-exchange-relaxation-free (SERF) magnetometer with a compact size of 14 mm × 25 mm × 90 mm was developed. The device has a high sensitivity of 25 fT/ Hz . Meanwhile, in the multichannel working mode, synchronous sensor manipulation and data acquisition can be achieved through our control software without additional data acquisition boards. Since a typical SERF magnetometer only responds to dual-axis magnetic fields, two sensors are orthogonally arranged to form a vector detection channel. Our system consists of seven channels and allows 7 × 9 vector MCG mapping by scanning. High-quality heart vector signals are measured, and P peak, QRS peak, and T peak can be distinguished clearly. To better demonstrate the vectorial information, a vector scatter plot form is also provided. Through a basic bio-electric current model, it demonstrates that triaxial MCG measurements capture a richer spatial current information than traditional uniaxial MCG, offering substantial diagnostic potential for heart diseases and shedding more light on the inversion of cardiac issues.
Collapse
Affiliation(s)
- Shengran Su
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Zhenyuan Xu
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Xiang He
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Guoyi Zhang
- Hangzhou Q-MAG Technology Co.,Ltd., Hangzhou, 310000, China
| | - Haijun Wu
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Yalan Gao
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Yueliang Ma
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Chanling Yin
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Yi Ruan
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Kan Li
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| | - Qiang Lin
- Zhejiang Provincial Key Laboratory and Collaborative Innovation Center for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou, 310000, China
| |
Collapse
|
23
|
Rier L, Rhodes N, Pakenham D, Boto E, Holmes N, Hill RM, Rivero GR, Shah V, Doyle C, Osborne J, Bowtell R, Taylor MJ, Brookes MJ. The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG study. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.01.04.573933. [PMID: 38260246 PMCID: PMC10802362 DOI: 10.1101/2024.01.04.573933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2024]
Abstract
Neural oscillations mediate the coordination of activity within and between brain networks, supporting cognition and behaviour. How these processes develop throughout childhood is not only an important neuroscientific question but could also shed light on the mechanisms underlying neurological and psychiatric disorders. However, measuring the neurodevelopmental trajectory of oscillations has been hampered by confounds from instrumentation. In this paper, we investigate the suitability of a disruptive new imaging platform - Optically Pumped Magnetometer-based magnetoencephalography (OPM-MEG) - to study oscillations during brain development. We show how a unique 192-channel OPM-MEG device, which is adaptable to head size and robust to participant movement, can be used to collect high-fidelity electrophysiological data in individuals aged between 2 and 34 years. Data were collected during a somatosensory task, and we measured both stimulus-induced modulation of beta oscillations in sensory cortex, and whole-brain connectivity, showing that both modulate significantly with age. Moreover, we show that pan-spectral bursts of electrophysiological activity drive task-induced beta modulation, and that their probability of occurrence and spectral content change with age. Our results offer new insights into the developmental trajectory of beta oscillations and provide clear evidence that OPM-MEG is an ideal platform for studying electrophysiology in neurodevelopment.
Collapse
Affiliation(s)
- Lukas Rier
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Natalie Rhodes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Diagnostic Imaging,The Hospital for Sick Children, 555 University Avenue, Toronto, M5G 1X8, Canada
| | - Daisie Pakenham
- Clinical Neurophysiology, Nottingham University Hospitals NHS Trust, Queens Medical Centre, Derby Rd, Lenton, Nottingham NG7 2UH, UK
| | - Elena Boto
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 7-8 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 7-8 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| | - Ryan M. Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 7-8 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| | - Gonzalo Reina Rivero
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Vishal Shah
- QuSpin Inc. 331 South 104th Street, Suite 130, Louisville, Colorado, 80027, USA
| | - Cody Doyle
- QuSpin Inc. 331 South 104th Street, Suite 130, Louisville, Colorado, 80027, USA
| | - James Osborne
- QuSpin Inc. 331 South 104th Street, Suite 130, Louisville, Colorado, 80027, USA
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Margot J. Taylor
- Diagnostic Imaging,The Hospital for Sick Children, 555 University Avenue, Toronto, M5G 1X8, Canada
| | - Matthew J. Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 7-8 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| |
Collapse
|
24
|
Schofield H, Hill RM, Feys O, Holmes N, Osborne J, Doyle C, Bobela D, Corvilian P, Wens V, Rier L, Bowtell R, Ferez M, Mullinger KJ, Coleman S, Rhodes N, Rea M, Tanner Z, Boto E, de Tiège X, Shah V, Brookes MJ. A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.03.06.583313. [PMID: 38558964 PMCID: PMC10979878 DOI: 10.1101/2024.03.06.583313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Magnetoencephalography (MEG) measures brain function via assessment of magnetic fields generated by neural currents. Conventional MEG uses superconducting sensors, which place significant limitations on performance, practicality, and deployment; however, the field has been revolutionised in recent years by the introduction of optically-pumped-magnetometers (OPMs). OPMs enable measurement of the MEG signal without cryogenics, and consequently the conception of 'OPM-MEG' systems which ostensibly allow increased sensitivity and resolution, lifespan compliance, free subject movement, and lower cost. However, OPM-MEG remains in its infancy with limitations on both sensor and system design. Here, we report a new OPM-MEG design with miniaturised and integrated electronic control, a high level of portability, and improved sensor dynamic range (arguably the biggest limitation of existing instrumentation). We show that this system produces equivalent measures when compared to an established instrument; specifically, when measuring task-induced beta-band, gamma-band and evoked neuro-electrical responses, source localisations from the two systems were highly comparable and temporal correlation was >0.7 at the individual level and >0.9 for groups. Using an electromagnetic phantom, we demonstrate improved dynamic range by running the system in background fields up to 8 nT. We show that the system is effective in gathering data during free movement (including a sitting-to-standing paradigm) and that it is compatible with simultaneous electroencephalography (EEG - the clinical standard). Finally, we demonstrate portability by moving the system between two laboratories. Overall, our new system is shown to be a significant step forward for OPM-MEG technology and offers an attractive platform for next generation functional medical imaging.
Collapse
Affiliation(s)
- Holly Schofield
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 2 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| | - Ryan M. Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 2 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| | - Odile Feys
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
- Université libre de Bruxelles, Hôpital Universitaire de Bruxelles, Hôpital Erasme, Department of neurology, Brussels, Belgium
| | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 2 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| | - James Osborne
- QuSpin Inc. 331 South 104 Street, Suite 130, Louisville, Colorado, 80027, USA
| | - Cody Doyle
- QuSpin Inc. 331 South 104 Street, Suite 130, Louisville, Colorado, 80027, USA
| | - David Bobela
- QuSpin Inc. 331 South 104 Street, Suite 130, Louisville, Colorado, 80027, USA
| | - Pierre Corvilian
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
| | - Vincent Wens
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
- Université libre de Bruxelles, Hôpital Universitaire de Bruxelles, Hôpital Erasme, Department of translational neuroimaging, Brussels, Belgium
| | - Lukas Rier
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Maxime Ferez
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
| | - Karen J. Mullinger
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Centre for Human Brain Health, School of Psychology, University of Birmingham, UK
| | - Sebastian Coleman
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Natalie Rhodes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Molly Rea
- Cerca Magnetics Limited, 2 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| | - Zoe Tanner
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 2 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| | - Elena Boto
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 2 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| | - Xavier de Tiège
- Université libre de Bruxelles, ULB Neuroscience Institute, Laboratoire de neuroanatomie et neuroimagerie translationelles, Brussels, Belgium
- Université libre de Bruxelles, Hôpital Universitaire de Bruxelles, Hôpital Erasme, Department of translational neuroimaging, Brussels, Belgium
| | - Vishal Shah
- QuSpin Inc. 331 South 104 Street, Suite 130, Louisville, Colorado, 80027, USA
| | - Matthew J. Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Cerca Magnetics Limited, 2 Castlebridge Office Village, Kirtley Drive, Nottingham, NG7 1LD, Nottingham, UK
| |
Collapse
|
25
|
Tierney TM, Seedat Z, St Pier K, Mellor S, Barnes GR. Adaptive multipole models of optically pumped magnetometer data. Hum Brain Mapp 2024; 45:e26596. [PMID: 38433646 PMCID: PMC10910270 DOI: 10.1002/hbm.26596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 12/14/2023] [Accepted: 12/29/2023] [Indexed: 03/05/2024] Open
Abstract
Multipole expansions have been used extensively in the Magnetoencephalography (MEG) literature for mitigating environmental interference and modelling brain signal. However, their application to Optically Pumped Magnetometer (OPM) data is challenging due to the wide variety of existing OPM sensor and array designs. We therefore explore how such multipole models can be adapted to provide stable models of brain signal and interference across OPM systems. Firstly, we demonstrate how prolate spheroidal (rather than spherical) harmonics can provide a compact representation of brain signal when sampling on the scalp surface with as few as 100 channels. We then introduce a type of orthogonal projection incorporating this basis set. The Adaptive Multipole Models (AMM), which provides robust interference rejection across systems, even in the presence of spatially structured nonlinearity errors (shielding factor is the reciprocal of the maximum fractional nonlinearity error). Furthermore, this projection is always stable, as it is an orthogonal projection, and will only ever decrease the white noise in the data. However, for array designs that are suboptimal for spatially separating brain signal and interference, this method can remove brain signal components. We contrast these properties with the more typically used multipole expansion, Signal Space Separation (SSS), which never reduces brain signal amplitude but is less robust to the effect of sensor nonlinearity errors on interference rejection and can increase noise in the data if the system is sub-optimally designed (as it is an oblique projection). We conclude with an empirical example utilizing AMM to maximize signal to noise ratio (SNR) for the stimulus locked neuronal response to a flickering visual checkerboard in a 128-channel OPM system and demonstrate up to 40 dB software shielding in real data.
Collapse
Affiliation(s)
- Tim M. Tierney
- Department of Imaging NeuroscienceUCL Queen Square Institute of Neurology, University College LondonLondonUK
| | | | - Kelly St Pier
- Diagnostic Suite, Young Epilepsy, St Piers LaneSurreyUK
| | - Stephanie Mellor
- Department of Imaging NeuroscienceUCL Queen Square Institute of Neurology, University College LondonLondonUK
| | - Gareth R. Barnes
- Department of Imaging NeuroscienceUCL Queen Square Institute of Neurology, University College LondonLondonUK
| |
Collapse
|
26
|
Bagić AI, Bowyer SM, Burgess RC, Funke ME, Lowden A, Mohamed IS, Wilson T, Zhang W, Zillgitt AJ, Tenney JR. Role of optically pumped magnetometers in presurgical epilepsy evaluation: Commentary of the American Clinical Magnetoencephalography Society. Epilepsia 2023; 64:3155-3159. [PMID: 37728519 DOI: 10.1111/epi.17770] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 08/18/2023] [Accepted: 09/08/2023] [Indexed: 09/21/2023]
Abstract
One of the major challenges of modern epileptology is the underutilization of epilepsy surgery for treatment of patients with focal, medication resistant epilepsy (MRE). Aggravating this distressing failure to deliver optimum care to these patients is the underuse of proven localizing tools, such as magnetoencephalography (MEG), a clinically validated, non-invasive, neurophysiological method used to directly measure and localize brain activity. A sizable mass of published evidence indicates that MEG can improve identification of surgical candidates and guide pre-surgical planning, increasing the yield of SEEG and improving operative outcomes. However, despite at least 10 common, evidence supported, clinical scenarios in MRE patients where MEG can offer non-redundant information and improve the pre-surgical evaluation, it is regularly used by only a minority of USA epilepsy centers. The current state of the art in MEG sensors employs SQUIDs, which require cooling with liquid helium to achieve superconductivity. This sensor technology has undergone significant generational improvement since whole head MEG scanners were introduced around in 1990s, but still has limitations. Further advances in sensor technology which may make ME G more easily accessible and affordable have been eagerly awaited, and development of new techniques should be encouraged. Of late, optically pumped magnetometers (OPMs) have received considerable attention, even prompting some potential acquisitions of new MEG systems to be put on hold, based on a hope that OPMs will usher in a new generation of MEG equipment and procedures. The development of any new clinical test used to guide intracranial EEG monitoring and/or surgical planning must address several specific issues. The goal of this commentary is to recognize the current state of OPM technology and to suggest a framework for it to advance in the clinical realm where it can eventually be deemed clinically valuable to physicians and patients. The American Clinical MEG Society (ACMEGS) strongly supports more advanced and less expensive technology and looks forward to continuing work with researchers to develop new sensors and clinical devices which will improve the experience and outcome for patients, and perhaps extend the role of MEG. However, currently, there are no OPM devices ready for practical clinical use. Based on the engineering obstacles and the clinical tradeoffs to be resolved, the assessment of experts suggests that there will most likely be another decade relying solely on "frozen SQUIDs" in the clinical MEG field.
Collapse
Affiliation(s)
- Anto I Bagić
- University of Pittsburgh Comprehensive Epilepsy Center, Department of Neurology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Susan M Bowyer
- MEG Laboratory, Henry Ford Hospital, Wayne State University, Detroit, Michigan, USA
| | - Richard C Burgess
- Magnetoencephalography Laboratory, Cleveland Clinic Epilepsy Center, Cleveland, Ohio, USA
| | - Michael E Funke
- Department of Pediatrics, University of Texas Health Science Center, McGovern Medical School, Houston, Texas, USA
| | - Andrea Lowden
- Division of Pediatric Neurology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Ismail S Mohamed
- Department of Pediatrics, University of Alabama, Birmingham, Alabama, USA
| | - Tony Wilson
- Institute for Human Neuroscience, Boys Town National Research Hospital, Boys Town, Nebraska, USA
| | - Wenbo Zhang
- Minnesota Epilepsy Group, Roseville, Minnesota, USA
| | - Andrew J Zillgitt
- Corewell Health William Beaumont University Hospital, Royal Oak, Minnesota, USA
| | - Jeffrey R Tenney
- MEG Center, Cincinnati Children's Hospital Medical Center, Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA
| |
Collapse
|
27
|
Iivanainen J, Carter TR, Trumbo MCS, McKay J, Taulu S, Wang J, Stephen JM, Schwindt PDD, Borna A. Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG. J Neural Eng 2023; 20:056032. [PMID: 37748476 DOI: 10.1088/1741-2552/acfcd9] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 09/25/2023] [Indexed: 09/27/2023]
Abstract
Objective.Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject's scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses.Approach.We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding.Main results.OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement.Significance.The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain-computer interfacing.
Collapse
Affiliation(s)
- Joonas Iivanainen
- Sandia National Laboratories, Albuquerque, NM 87185, United States of America
| | - Tony R Carter
- Sandia National Laboratories, Albuquerque, NM 87185, United States of America
| | - Michael C S Trumbo
- Sandia National Laboratories, Albuquerque, NM 87185, United States of America
| | - Jim McKay
- Candoo Systems Inc, Port Coquitlam, BC, Canada
| | - Samu Taulu
- University of Washington, Seattle, WA, United States of America
| | - Jun Wang
- Department of Speech, Language, and Hearing Sciences, The University of Texas at Austin, Austin, TX, United States of America
- Department of Neurology, The University of Texas at Austin, Austin, TX, United States of America
| | - Julia M Stephen
- The Mind Research Network a Division of Lovelace Biomedical Research Institute, Albuquerque, NM 87106, United States of America
| | - Peter D D Schwindt
- Sandia National Laboratories, Albuquerque, NM 87185, United States of America
| | - Amir Borna
- Sandia National Laboratories, Albuquerque, NM 87185, United States of America
| |
Collapse
|
28
|
Cao F, An N, Xu W, Wang W, Li W, Wang C, Xiang M, Gao Y, Ning X. Optical Co-Registration Method of Triaxial OPM-MEG and MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2023; 42:2706-2713. [PMID: 37015113 DOI: 10.1109/tmi.2023.3263167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
The advent of optically pumped magnetometers (OPMs) facilitates the development of on-scalp magnetoencephalography (MEG). In particular, the triaxial OPM emerged recently, making simultaneous measurements of all three orthogonal components of vector fields possible. The detection of triaxial magnetic fields improves the interference suppression capability and achieves higher source localization accuracy using fewer sensors. The source localization accuracy of MEG is based on the accurate co-registration of MEG and MRI. In this study, we proposed a triaxial co-registration method according to combined principal component analysis and iterative closest point algorithms for use of a flexible cap. A reference phantom with known sensor positions and orientations was designed and constructed to evaluate the accuracy of the proposed method. Experiments showed that the average co-registered position errors of all sensors were approximately 1 mm and average orientation errors were less than 2.5° in the X -and Y orientations and less than 1.6° in the Z orientation. Furthermore, we assessed the influence of co-registration errors on the source localization using simulations. The average source localization error of approximately 1 mm reflects the effectiveness of the co-registration method. The proposed co-registration method facilitates future applications of triaxial sensors on flexible caps.
Collapse
|
29
|
Cao F, Gao Z, Qi S, Chen K, Xiang M, An N, Ning X. Realistic three-layer head phantom for optically pumped magnetometer-based magnetoencephalography. Comput Biol Med 2023; 164:107318. [PMID: 37595517 DOI: 10.1016/j.compbiomed.2023.107318] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 07/03/2023] [Accepted: 08/07/2023] [Indexed: 08/20/2023]
Abstract
The advent of optically pumped magnetometer-based magnetoencephalography (OPM-MEG) has introduced new tools for neuroscience and clinical research. As it is still under development, the achievable performance of OPM-MEG remains to be tested, particularly in terms of source localization accuracy, which can be influenced by various factors, including software and hardware aspects. A feasible approach to comprehensively test the performance of the OPM-MEG system is to utilize a phantom that simulates the actual electrophysiological properties of the head while ensuring the precise locations of dipole sources. However, conventional water or dry phantoms can only simulate a single-sphere head model. In this work, a more realistic three-layer phantom was designed and fabricated. The proposed phantom included the scalp, skull, and cortex tissues of the head, as well as the simulated dipole sources. The scalp and cortex tissues were simulated using an electrolyte solution, while the dipole source was constructed from a coaxial cable. All main structures in the phantom were produced using 3D printing techniques, making the phantom easy to manufacture. The fabricated phantom was tested on a 36-channel OPM-MEG system, and the results showed that the dipole source inside the phantom could generate a magnetic field distribution on the scalp that was close to its theoretical values. The average source localization accuracy of 5.51 mm verified the effectiveness of the designed phantom and the performance of our OPM-MEG system. This work provides an effective test platform for OPM-MEG.
Collapse
Affiliation(s)
- Fuzhi Cao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou 310028, China
| | - Zhenfeng Gao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
| | - Shengjie Qi
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
| | - Kaihua Chen
- Quanum Life Sciences, Hangzhou, 310051, China
| | - Min Xiang
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou 310028, China; Zhejiang Provincial Key Laboratory of Ultra-Weak Magnetic-Field Space and Applied Technology, Hangzhou Innovation Institute, Beihang University, Hangzhou, 310051, China; Hefei National Laboratory, Hefei 230088, China
| | - Nan An
- Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou 310028, China; Zhejiang Provincial Key Laboratory of Ultra-Weak Magnetic-Field Space and Applied Technology, Hangzhou Innovation Institute, Beihang University, Hangzhou, 310051, China; Hefei National Laboratory, Hefei 230088, China.
| | - Xiaolin Ning
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou 310028, China; Zhejiang Provincial Key Laboratory of Ultra-Weak Magnetic-Field Space and Applied Technology, Hangzhou Innovation Institute, Beihang University, Hangzhou, 310051, China; Hefei National Laboratory, Hefei 230088, China.
| |
Collapse
|
30
|
Zhdanov A, Nurminen J, Iivanainen J, Taulu S. A minimum assumption approach to MEG sensor array design. Phys Med Biol 2023; 68:175030. [PMID: 37385260 PMCID: PMC10481949 DOI: 10.1088/1361-6560/ace306] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 06/14/2023] [Accepted: 06/29/2023] [Indexed: 07/01/2023]
Abstract
Objective.Our objective is to formulate the problem of the magnetoencephalographic (MEG) sensor array design as a well-posed engineering problem of accurately measuring the neuronal magnetic fields. This is in contrast to the traditional approach that formulates the sensor array design problem in terms of neurobiological interpretability the sensor array measurements.Approach.We use the vector spherical harmonics (VSH) formalism to define a figure-of-merit for an MEG sensor array. We start with an observation that, under certain reasonable assumptions, any array ofmperfectly noiseless sensors will attain exactly the same performance, regardless of the sensors' locations and orientations (with the exception of a negligible set of singularly bad sensor configurations). We proceed to the conclusion that under the aforementioned assumptions, the only difference between different array configurations is the effect of (sensor) noise on their performance. We then propose a figure-of-merit that quantifies, with a single number, how much the sensor array in question amplifies the sensor noise.Main results.We derive a formula for intuitively meaningful, yet mathematically rigorous figure-of-merit that summarizes how desirable a particular sensor array design is. We demonstrate that this figure-of-merit is well-behaved enough to be used as a cost function for a general-purpose nonlinear optimization methods such as simulated annealing. We also show that sensor array configurations obtained by such optimizations exhibit properties that are typically expected of 'high-quality' MEG sensor arrays, e.g. high channel information capacity.Significance.Our work paves the way toward designing better MEG sensor arrays by isolating the engineering problem of measuring the neuromagnetic fields out of the bigger problem of studying brain function through neuromagnetic measurements.
Collapse
Affiliation(s)
- Andrey Zhdanov
- BioMag Laboratory, HUS Diagnostic Center, Helsinki University Hospital and University of
Helsinki, Helsinki, Finland
- Department of Physics, University
of Washington, Seattle, WA, United States of
America
| | - Jussi Nurminen
- Motion Analysis Laboratory, Children’s Hospital, University of Helsinki and Helsinki University
Hospital, Helsinki, Finland
| | - Joonas Iivanainen
- Sandia National Laboratories, Albuquerque, NM 87185, United
States of America
| | - Samu Taulu
- Department of Physics, University
of Washington, Seattle, WA, United States of
America
- Institute for Learning and Brain Sciences, University of Washington, Seattle, WA,
United States of America
| |
Collapse
|
31
|
Holmes N, Rea M, Hill RM, Leggett J, Edwards LJ, Hobson PJ, Boto E, Tierney TM, Rier L, Rivero GR, Shah V, Osborne J, Fromhold TM, Glover P, Brookes MJ, Bowtell R. Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding. Neuroimage 2023; 274:120157. [PMID: 37149237 PMCID: PMC10465235 DOI: 10.1016/j.neuroimage.2023.120157] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 04/13/2023] [Accepted: 05/03/2023] [Indexed: 05/08/2023] Open
Abstract
The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions. Existing active shielding systems only compensate fields over small, fixed regions and do not allow ambulatory movement. Here we describe the matrix coil, a new type of active shielding system for OPM-MEG which is formed from 48 square unit coils arranged on two planes which can compensate magnetic fields in regions that can be flexibly placed between the planes. Through the integration of optical tracking with OPM data acquisition, field changes induced by participant movement are cancelled with low latency (25 ms). High-quality MEG source data were collected despite the presence of large (65 cm translations and 270° rotations) ambulatory participant movements.
Collapse
Affiliation(s)
- Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK.
| | - Molly Rea
- Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Ryan M Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK
| | - James Leggett
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Lucy J Edwards
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Peter J Hobson
- School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Elena Boto
- Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Tim M Tierney
- Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, London WC1N 3AR, UK
| | - Lukas Rier
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Gonzalo Reina Rivero
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK
| | - Vishal Shah
- QuSpin Inc., 331 South 104th Street, Suite 130, Louisville, CO 80027, USA
| | - James Osborne
- QuSpin Inc., 331 South 104th Street, Suite 130, Louisville, CO 80027, USA
| | - T Mark Fromhold
- School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Paul Glover
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Matthew J Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK; Cerca Magnetics Limited, Unit 2 Castlebridge Office Village, Kirtley Drive, Nottingham NG7 1LD, UK
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| |
Collapse
|
32
|
Takeda Y, Gomi T, Umebayashi R, Tomita S, Suzuki K, Hiroe N, Saikawa J, Munaka T, Yamashita O. Sensor array design of optically pumped magnetometers for accurately estimating source currents. Neuroimage 2023:120257. [PMID: 37392806 DOI: 10.1016/j.neuroimage.2023.120257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 04/21/2023] [Accepted: 06/28/2023] [Indexed: 07/03/2023] Open
Abstract
An optically pumped magnetometer (OPM) is a new generation of magnetoencephalography (MEG) devices that is small, light, and works at room temperature. Due to these characteristics, OPMs enable flexible and wearable MEG systems. On the other hand, if we have a limited number of OPM sensors, we need to carefully design their sensor arrays depending on our purposes and regions of interests (ROIs). In this study, we propose a method that designs OPM sensor arrays for accurately estimating the cortical currents at the ROIs. Based on the resolution matrix of minimum norm estimate (MNE), our method sequentially determines the position of each sensor to optimize its inverse filter pointing to the ROIs and suppressing the signal leakage from the other areas. We call this method the Sensor array Optimization based on Resolution Matrix (SORM). We conducted simple and realistic simulation tests to evaluate its characteristics and efficacy for real OPM-MEG data. SORM designed the sensor arrays so that their leadfield matrices had high effective ranks as well as high sensitivities to ROIs. Although SORM is based on MNE, the sensor arrays designed by SORM were effective not only when we estimated the cortical currents by MNE but also when we did so by other methods. With real OPM-MEG data we confirmed its validity for real data. These analyses suggest that SORM is especially useful when we want to accurately estimate ROIs' activities with a limited number of OPM sensors, such as brain-machine interfaces and diagnosing brain diseases.
Collapse
Affiliation(s)
- Yusuke Takeda
- Computational Brain Dynamics Team, RIKEN Center for Advanced Intelligence Project, 2-2-2 Hikaridai, Seika-cho, Soraku-gun, Kyoto, 619-0288, Japan; Department of Computational Brain Imaging, ATR Neural Information Analysis Laboratories, 2-2-2 Hikaridai, Seika-cho, Soraku-gun, Kyoto, 619-0288, Japan.
| | - Tomohiro Gomi
- Technology Research Laboratory, Shimadzu Corporation, 3-9-4 Hikaridai, Seika-cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Ryu Umebayashi
- Technology Research Laboratory, Shimadzu Corporation, 3-9-4 Hikaridai, Seika-cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Sadamu Tomita
- Technology Research Laboratory, Shimadzu Corporation, 3-9-4 Hikaridai, Seika-cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Keita Suzuki
- Department of Computational Brain Imaging, ATR Neural Information Analysis Laboratories, 2-2-2 Hikaridai, Seika-cho, Soraku-gun, Kyoto, 619-0288, Japan
| | - Nobuo Hiroe
- Department of Computational Brain Imaging, ATR Neural Information Analysis Laboratories, 2-2-2 Hikaridai, Seika-cho, Soraku-gun, Kyoto, 619-0288, Japan
| | - Jiro Saikawa
- Technology Research Laboratory, Shimadzu Corporation, 3-9-4 Hikaridai, Seika-cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Tatsuya Munaka
- Technology Research Laboratory, Shimadzu Corporation, 3-9-4 Hikaridai, Seika-cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Okito Yamashita
- Computational Brain Dynamics Team, RIKEN Center for Advanced Intelligence Project, 2-2-2 Hikaridai, Seika-cho, Soraku-gun, Kyoto, 619-0288, Japan; Department of Computational Brain Imaging, ATR Neural Information Analysis Laboratories, 2-2-2 Hikaridai, Seika-cho, Soraku-gun, Kyoto, 619-0288, Japan
| |
Collapse
|
33
|
Rhodes N, Rea M, Boto E, Rier L, Shah V, Hill RM, Osborne J, Doyle C, Holmes N, Coleman SC, Mullinger K, Bowtell R, Brookes MJ. Measurement of Frontal Midline Theta Oscillations using OPM-MEG. Neuroimage 2023; 271:120024. [PMID: 36918138 PMCID: PMC10465234 DOI: 10.1016/j.neuroimage.2023.120024] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 02/10/2023] [Accepted: 03/11/2023] [Indexed: 03/14/2023] Open
Abstract
Optically pumped magnetometers (OPMs) are an emerging lightweight and compact sensor that can measure magnetic fields generated by the human brain. OPMs enable construction of wearable magnetoencephalography (MEG) systems, which offer advantages over conventional instrumentation. However, when trying to measure signals at low frequency, higher levels of inherent sensor noise, magnetic interference and movement artefact introduce a significant challenge. Accurate characterisation of low frequency brain signals is important for neuroscientific, clinical, and paediatric MEG applications and consequently, demonstrating the viability of OPMs in this area is critical. Here, we undertake measurement of theta band (4-8 Hz) neural oscillations and contrast a newly developed 174 channel triaxial wearable OPM-MEG system with conventional (cryogenic-MEG) instrumentation. Our results show that visual steady state responses at 4 Hz, 6 Hz and 8 Hz can be recorded using OPM-MEG with a signal-to-noise ratio (SNR) that is not significantly different to conventional MEG. Moreover, we measure frontal midline theta oscillations during a 2-back working memory task, again demonstrating comparable SNR for both systems. We show that individual differences in both the amplitude and spatial signature of induced frontal-midline theta responses are maintained across systems. Finally, we show that our OPM-MEG results could not have been achieved without a triaxial sensor array, or the use of postprocessing techniques. Our results demonstrate the viability of OPMs for characterising theta oscillations and add weight to the argument that OPMs can replace cryogenic sensors as the fundamental building block of MEG systems.
Collapse
Affiliation(s)
- Natalie Rhodes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Molly Rea
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Elena Boto
- Cerca Magnetics Ltd. 2, Castlebridge Office Village, Kirtley Dr, Nottingham NG7 1LD; Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Lukas Rier
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Vishal Shah
- QuSpin Inc. 331 South 104th Street, Suite 130, Louisville, Colorado, 80027, USA
| | - Ryan M Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK; Cerca Magnetics Ltd. 2, Castlebridge Office Village, Kirtley Dr, Nottingham NG7 1LD
| | - James Osborne
- QuSpin Inc. 331 South 104th Street, Suite 130, Louisville, Colorado, 80027, USA
| | - Cody Doyle
- QuSpin Inc. 331 South 104th Street, Suite 130, Louisville, Colorado, 80027, USA
| | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK; Cerca Magnetics Ltd. 2, Castlebridge Office Village, Kirtley Dr, Nottingham NG7 1LD
| | - Sebastian C Coleman
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Karen Mullinger
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK; Centre for Human Brain Health, School of Psychology, University of Birmingham, Birmingham, B15 2TT, UK
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Matthew J Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK; Cerca Magnetics Ltd. 2, Castlebridge Office Village, Kirtley Dr, Nottingham NG7 1LD.
| |
Collapse
|
34
|
Skidchenko E, Butorina A, Ostras M, Vetoshko P, Kuzmichev A, Yavich N, Malovichko M, Koshev N. Yttrium-Iron Garnet Magnetometer in MEG: Advance towards Multi-Channel Arrays. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094256. [PMID: 37177460 PMCID: PMC10181089 DOI: 10.3390/s23094256] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 04/17/2023] [Accepted: 04/23/2023] [Indexed: 05/15/2023]
Abstract
Recently, a new kind of sensor applicable in magnetoencephalography (MEG) has been presented: a solid-state yttrium-iron garnet magnetometer (YIGM). The feasibility of yttrium-iron garnet magnetometers (YIGMs) was demonstrated in an alpha-rhythm registration experiment. In this paper, we propose the analysis of lead-field matrices for different possible multi-channel on-scalp sensor layouts using YIGMs with respect to information theory. Real noise levels of the new sensor were used to compute signal-to-noise ratio (SNR) and total information capacity (TiC), and compared with corresponding metrics that can be obtained with well-established MEG systems based on superconducting quantum interference devices (SQUIDs) and optically pumped magnetometers (OPMs). The results showed that due to YIGMs' proximity to the subject's scalp, they outperform SQUIDs and OPMs at their respective noise levels in terms of SNR and TiC. However, the current noise levels of YIGM sensors are unfortunately insufficient for constructing a multichannel YIG-MEG system. This simulation study provides insight into the direction for further development of YIGM sensors to create a multi-channel MEG system, namely, by decreasing the noise levels of sensors.
Collapse
Affiliation(s)
| | - Anna Butorina
- CNBR, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
| | - Maxim Ostras
- M-Granat, Russian Quantum Center, 121205 Moscow, Russia
| | - Petr Vetoshko
- M-Granat, Russian Quantum Center, 121205 Moscow, Russia
- Laboratory of Magnetic Phenomena in Microelectronics, Kotelnikov Institute of Radioengineering and Electronics of RAS, 125009 Moscow, Russia
| | | | - Nikolay Yavich
- CNBR, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
- Computational Geophysics Lab, Moscow Institute of Physics and Technology, 141701 Dolgoprudny, Russia
| | - Mikhail Malovichko
- Computational Geophysics Lab, Moscow Institute of Physics and Technology, 141701 Dolgoprudny, Russia
| | - Nikolay Koshev
- CNBR, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia
| |
Collapse
|
35
|
Wens V. Exploring the limits of MEG spatial resolution with multipolar expansions. Neuroimage 2023; 270:119953. [PMID: 36842521 DOI: 10.1016/j.neuroimage.2023.119953] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 02/17/2023] [Indexed: 02/26/2023] Open
Abstract
The advent of scalp magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) may represent a step change in the field of human electrophysiology. Compared to cryogenic MEG based on superconducting quantum interference devices (SQUIDs, placed 2-4 cm above scalp), scalp MEG promises significantly higher spatial resolution imaging but it also comes with numerous challenges regarding how to optimally design OPM arrays. In this context, we sought to provide a systematic description of MEG spatial resolution as a function of the number of sensors (allowing comparison of low- vs. high-density MEG), sensor-to-brain distance (cryogenic SQUIDs vs. scalp OPM), sensor type (magnetometers vs. gradiometers; single- vs. multi-component sensors), and signal-to-noise ratio. To that aim, we present an analytical theory based on MEG multipolar expansions that enables, once supplemented with experimental input and simulations, quantitative assessment of the limits of MEG spatial resolution in terms of two qualitatively distinct regimes. In the regime of asymptotically high-density MEG, we provide a mathematically rigorous description of how magnetic field smoothness constraints spatial resolution to a slow, logarithmic divergence. In the opposite regime of low-density MEG, it is sensor density that constraints spatial resolution to a faster increase following a square-root law. The transition between these two regimes controls how MEG spatial resolution saturates as sensors approach sources of neural activity. This two-regime model of MEG spatial resolution integrates known observations (e.g., the difficulty of improving spatial resolution by increasing sensor density, the gain brought by moving sensors on scalp, or the usefulness of multi-component sensors) and gathers them under a unifying theoretical framework that highlights the underlying physics and reveals properties inaccessible to simulations. We propose that this framework may find useful applications to benchmark the design of future OPM-based scalp MEG systems.
Collapse
Affiliation(s)
- Vincent Wens
- LN(2)T - Laboratoire de Neuroanatomie et Neuroimagerie translationnelles, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), Brussels, Belgium; Department of Translational Neuroimaging, H.U.B. - Hôpital Erasme, Brussels, Belgium.
| |
Collapse
|
36
|
Schofield H, Boto E, Shah V, Hill RM, Osborne J, Rea M, Doyle C, Holmes N, Bowtell R, Woolger D, Brookes MJ. Quantum enabled functional neuroimaging: the why and how of magnetoencephalography using optically pumped magnetometers. CONTEMPORARY PHYSICS 2023; 63:161-179. [PMID: 38463461 PMCID: PMC10923587 DOI: 10.1080/00107514.2023.2182950] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 02/06/2023] [Indexed: 03/12/2024]
Abstract
Non-invasive imaging has transformed neuroscientific discovery and clinical practice, providing a non-invasive window into the human brain. However, whilst techniques like MRI generate ever more precise images of brain structure, in many cases, it's the function within neural networks that underlies disease. Here, we review the potential for quantum-enabled magnetic field sensors to shed light on such activity. Specifically, we describe how optically pumped magnetometers (OPMs) enable magnetoencephalographic (MEG) recordings with higher accuracy and improved practicality compared to the current state-of-the-art. The paper is split into two parts: first, we describe the work to date on OPM-MEG, detailing why this novel biomagnetic imaging technique is proving disruptive. Second, we explain how fundamental physics, including quantum mechanics and electromagnetism, underpins this developing technology. We conclude with a look to the future, outlining the potential for OPM-MEG to initiate a step change in the understanding and management of brain health.
Collapse
Affiliation(s)
- Holly Schofield
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
- Cerca Magnetics Limited, Nottingham, UK
| | - Elena Boto
- Cerca Magnetics Limited, Nottingham, UK
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | | | - Ryan M Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
- Cerca Magnetics Limited, Nottingham, UK
| | | | - Molly Rea
- Cerca Magnetics Limited, Nottingham, UK
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | | | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
- Cerca Magnetics Limited, Nottingham, UK
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | | | - Matthew J Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
- Cerca Magnetics Limited, Nottingham, UK
| |
Collapse
|
37
|
Kida T, Tanaka E, Kakigi R, Inui K. Brain-wide network analysis of resting-state neuromagnetic data. Hum Brain Mapp 2023; 44:3519-3540. [PMID: 36988453 DOI: 10.1002/hbm.26295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 03/16/2023] [Accepted: 03/20/2023] [Indexed: 03/30/2023] Open
Abstract
The present study performed a brain-wide network analysis of resting-state magnetoencephalograms recorded from 53 healthy participants to visualize elaborate brain maps of phase- and amplitude-derived graph-theory metrics at different frequencies. To achieve this, we conducted a vertex-wise computation of threshold-independent graph metrics by combining proportional thresholding and a conjunction analysis and applied them to a correlation analysis of age and brain networks. Source power showed a frequency-dependent cortical distribution. Threshold-independent graph metrics derived from phase- and amplitude-based connectivity showed similar or different distributions depending on frequency. Vertex-wise age-brain correlation maps revealed that source power at the beta band and the amplitude-based degree at the alpha band changed with age in local regions. The present results indicate that a brain-wide analysis of neuromagnetic data has the potential to reveal neurophysiological network features in the human brain in a resting state.
Collapse
Affiliation(s)
- Tetsuo Kida
- Higher Brain Function Unit, Department of Functioning and Disability, Institute for Developmental Research, Aichi Developmental Disability Center, Kasugai, Japan
- Department of Functioning and Disability, Institute for Developmental Research, Aichi Developmental Disability Center, Kasugai, Japan
- Department of Integrative Physiology, National Institute for Physiological Sciences, Okazaki, Japan
- Section of Brain Function Information, Supportive Center for Brain Research, National Institute for Physiological Sciences, Okazaki, Japan
| | - Emi Tanaka
- Brain and Mind Research Center, Nagoya University, Nagoya, Japan
| | - Ryusuke Kakigi
- Department of Integrative Physiology, National Institute for Physiological Sciences, Okazaki, Japan
| | - Koji Inui
- Department of Functioning and Disability, Institute for Developmental Research, Aichi Developmental Disability Center, Kasugai, Japan
- Department of Integrative Physiology, National Institute for Physiological Sciences, Okazaki, Japan
- Section of Brain Function Information, Supportive Center for Brain Research, National Institute for Physiological Sciences, Okazaki, Japan
| |
Collapse
|
38
|
Hillebrand A, Holmes N, Sijsma N, O'Neill GC, Tierney TM, Liberton N, Stam AH, van Klink N, Stam CJ, Bowtell R, Brookes MJ, Barnes GR. Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers. Sci Rep 2023; 13:4623. [PMID: 36944674 PMCID: PMC10030968 DOI: 10.1038/s41598-023-31111-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 03/06/2023] [Indexed: 03/23/2023] Open
Abstract
Magneto- and electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio (SNR) and thereby the sensitivity to activity from deep structures such as the hippocampus. This effect is amplified in children, for whom adult-sized fixed-helmet systems are typically too big. Moreover, ictal recordings with fixed-helmet systems are problematic because of limited movement tolerance and/or logistical considerations. Optically Pumped Magnetometers (OPMs) can be placed directly on the scalp, thereby improving SNR and enabling recordings during seizures. We aimed to demonstrate the performance of OPMs in a clinical population. Seven patients with challenging cases of epilepsy underwent MEG recordings using a 12-channel OPM-system and a 306-channel cryogen-based whole-head system: three adults with known deep or weak (low SNR) sources of interictal epileptiform discharges (IEDs), along with three children with focal epilepsy and one adult with frequent seizures. The consistency of the recorded IEDs across the two systems was assessed. In one patient the OPMs detected IEDs that were not found with the SQUID-system, and in two patients no IEDs were found with either system. For the other patients the OPM data were remarkably consistent with the data from the cryogenic system, noting that these were recorded in different sessions, with comparable SNRs and IED-yields overall. Importantly, the wearability of OPMs enabled the recording of seizure activity in a patient with hyperkinetic movements during the seizure. The observed ictal onset and semiology were in agreement with previous video- and stereo-EEG recordings. The relatively affordable technology, in combination with reduced running and maintenance costs, means that OPM-based MEG could be used more widely than current MEG systems, and may become an affordable alternative to scalp EEG, with the potential benefits of increased spatial accuracy, reduced sensitivity to volume conduction/field spread, and increased sensitivity to deep sources. Wearable MEG thus provides an unprecedented opportunity for epilepsy, and given its patient-friendliness, we envisage that it will not only be used for presurgical evaluation of epilepsy patients, but also for diagnosis after a first seizure.
Collapse
Affiliation(s)
- Arjan Hillebrand
- Department of Clinical Neurophysiology and Magnetoencephalography Center, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081HV, Amsterdam, The Netherlands.
- Brain Imaging, Amsterdam Neuroscience, Amsterdam, The Netherlands.
- Systems and Network Neurosciences, Amsterdam Neuroscience, Amsterdam, The Netherlands.
| | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Ndedi Sijsma
- Department of Clinical Neurophysiology and Magnetoencephalography Center, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081HV, Amsterdam, The Netherlands
| | - George C O'Neill
- Wellcome Centre for Human Neuroimaging, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, WC1N 3AR, UK
| | - Tim M Tierney
- Wellcome Centre for Human Neuroimaging, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, WC1N 3AR, UK
| | - Niels Liberton
- Department of Medical Technology, 3D Innovation Lab, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Anine H Stam
- Department of Clinical Neurophysiology and Magnetoencephalography Center, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081HV, Amsterdam, The Netherlands
| | - Nicole van Klink
- Department of Neurology and Neurosurgery, UMC Utrecht Brain Center, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - Cornelis J Stam
- Department of Clinical Neurophysiology and Magnetoencephalography Center, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081HV, Amsterdam, The Netherlands
- Brain Imaging, Amsterdam Neuroscience, Amsterdam, The Netherlands
- Neurodegeneration, Amsterdam Neuroscience, Amsterdam, The Netherlands
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Matthew J Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Gareth R Barnes
- Wellcome Centre for Human Neuroimaging, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, WC1N 3AR, UK
| |
Collapse
|
39
|
Su S, Xu Z, He X, Yin C, Kong M, Zhang X, Ruan Y, Li K, Lin Q. An Integrated Single-Beam Three-Axis High-Sensitivity Magnetometer. SENSORS (BASEL, SWITZERLAND) 2023; 23:3148. [PMID: 36991859 PMCID: PMC10058269 DOI: 10.3390/s23063148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 03/08/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.
Collapse
Affiliation(s)
- Shengran Su
- Zhejiang Provincial Key Laboratory for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Zhenyuan Xu
- Zhejiang Provincial Key Laboratory for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
- Hangzhou Qmag Technology Co., Ltd., Hangzhou 310023, China
| | - Xiang He
- Zhejiang Provincial Key Laboratory for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Chanling Yin
- Zhejiang Provincial Key Laboratory for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Miao Kong
- Zhejiang Provincial Key Laboratory for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Xuyuan Zhang
- Zhejiang Provincial Key Laboratory for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Yi Ruan
- Zhejiang Provincial Key Laboratory for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Kan Li
- Zhejiang Provincial Key Laboratory for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| | - Qiang Lin
- Zhejiang Provincial Key Laboratory for Quantum Precision Measurement, College of Science, Zhejiang University of Technology, Hangzhou 310023, China
| |
Collapse
|
40
|
Gutteling TP, Bonnefond M, Clausner T, Daligault S, Romain R, Mitryukovskiy S, Fourcault W, Josselin V, Le Prado M, Palacios-Laloy A, Labyt E, Jung J, Schwartz D. A New Generation of OPM for High Dynamic and Large Bandwidth MEG: The 4He OPMs-First Applications in Healthy Volunteers. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23052801. [PMID: 36905007 PMCID: PMC10006929 DOI: 10.3390/s23052801] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 02/16/2023] [Accepted: 02/24/2023] [Indexed: 06/06/2023]
Abstract
MagnetoEncephaloGraphy (MEG) provides a measure of electrical activity in the brain at a millisecond time scale. From these signals, one can non-invasively derive the dynamics of brain activity. Conventional MEG systems (SQUID-MEG) use very low temperatures to achieve the necessary sensitivity. This leads to severe experimental and economical limitations. A new generation of MEG sensors is emerging: the optically pumped magnetometers (OPM). In OPM, an atomic gas enclosed in a glass cell is traversed by a laser beam whose modulation depends on the local magnetic field. MAG4Health is developing OPMs using Helium gas (4He-OPM). They operate at room temperature with a large dynamic range and a large frequency bandwidth and output natively a 3D vectorial measure of the magnetic field. In this study, five 4He-OPMs were compared to a classical SQUID-MEG system in a group of 18 volunteers to evaluate their experimental performances. Considering that the 4He-OPMs operate at real room temperature and can be placed directly on the head, our assumption was that 4He-OPMs would provide a reliable recording of physiological magnetic brain activity. Indeed, the results showed that the 4He-OPMs showed very similar results to the classical SQUID-MEG system by taking advantage of a shorter distance to the brain, despite having a lower sensitivity.
Collapse
Affiliation(s)
- Tjerk P. Gutteling
- CERMEP-Imagerie du Vivant, MEG Departement, 69000 Lyon, France
- CRNL, UMR_S 1028, HCL, Université Lyon 1, 69000 Lyon, France
| | | | - Tommy Clausner
- CRNL, UMR_S 1028, HCL, Université Lyon 1, 69000 Lyon, France
| | | | | | | | - William Fourcault
- CEA LETI, Minatec Campus, Université Grenoble Alpes, 38000 Grenoble, France
| | - Vincent Josselin
- CEA LETI, Minatec Campus, Université Grenoble Alpes, 38000 Grenoble, France
| | | | | | | | - Julien Jung
- CRNL, UMR_S 1028, HCL, Université Lyon 1, 69000 Lyon, France
| | - Denis Schwartz
- CERMEP-Imagerie du Vivant, MEG Departement, 69000 Lyon, France
- CRNL, UMR_S 1028, HCL, Université Lyon 1, 69000 Lyon, France
| |
Collapse
|
41
|
Aslam N, Zhou H, Urbach EK, Turner MJ, Walsworth RL, Lukin MD, Park H. Quantum sensors for biomedical applications. NATURE REVIEWS. PHYSICS 2023; 5:157-169. [PMID: 36776813 PMCID: PMC9896461 DOI: 10.1038/s42254-023-00558-3] [Citation(s) in RCA: 67] [Impact Index Per Article: 33.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Accepted: 01/10/2023] [Indexed: 05/09/2023]
Abstract
Quantum sensors are finding their way from laboratories to the real world, as witnessed by the increasing number of start-ups in this field. The atomic length scale of quantum sensors and their coherence properties enable unprecedented spatial resolution and sensitivity. Biomedical applications could benefit from these quantum technologies, but it is often difficult to evaluate the potential impact of the techniques. This Review sheds light on these questions, presenting the status of quantum sensing applications and discussing their path towards commercialization. The focus is on two promising quantum sensing platforms: optically pumped atomic magnetometers, and nitrogen-vacancy centres in diamond. The broad spectrum of biomedical applications is highlighted by four case studies ranging from brain imaging to single-cell spectroscopy.
Collapse
Affiliation(s)
- Nabeel Aslam
- Department of Physics, Harvard University, Cambridge, MA USA
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA USA
- Institute of Condensed Matter Physics, Technische Universität Braunschweig, Braunschweig, Germany
| | - Hengyun Zhou
- Department of Physics, Harvard University, Cambridge, MA USA
| | - Elana K. Urbach
- Department of Physics, Harvard University, Cambridge, MA USA
| | - Matthew J. Turner
- Quantum Technology Center, University of Maryland, College Park, MD USA
- Department of Electrical and Computer Engineering, University of Maryland, College Park, MD USA
| | - Ronald L. Walsworth
- Quantum Technology Center, University of Maryland, College Park, MD USA
- Department of Electrical and Computer Engineering, University of Maryland, College Park, MD USA
- Department of Physics, University of Maryland, College Park, MD USA
| | | | - Hongkun Park
- Department of Physics, Harvard University, Cambridge, MA USA
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA USA
| |
Collapse
|
42
|
Bezsudnova Y, Koponen LM, Barontini G, Jensen O, Kowalczyk AU. Optimising the sensing volume of OPM sensors for MEG source reconstruction. Neuroimage 2022; 264:119747. [PMID: 36403733 PMCID: PMC7615061 DOI: 10.1016/j.neuroimage.2022.119747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 10/17/2022] [Accepted: 11/08/2022] [Indexed: 11/19/2022] Open
Abstract
Magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has been hailed as the future of electrophysiological recordings from the human brain. In this work, we investigate how the dimensions of the sensing volume (the vapour cell) affect the performance of both a single OPM-MEG sensor and a multi-sensor OPM-MEG system. We consider a realistic noise model that accounts for background brain activity and residual noise. By using source reconstruction metrics such as localization accuracy and time-course reconstruction accuracy, we demonstrate that the best overall sensitivity and reconstruction accuracy are achieved with cells that are significantly longer and wider that those of the majority of current commercial OPM sensors. Our work provides useful tools to optimise the cell dimensions of OPM sensors in a wide range of environments.
Collapse
Affiliation(s)
- Yulia Bezsudnova
- School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham, B15 2TT, United Kingdom
| | - Lari M Koponen
- Centre for Human Brain Health, School of Psychology, University of Birmingham, Edgbaston, Birmingham, B15 2SA, United Kingdom
| | - Giovanni Barontini
- School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham, B15 2TT, United Kingdom; Centre for Human Brain Health, School of Psychology, University of Birmingham, Edgbaston, Birmingham, B15 2SA, United Kingdom
| | - Ole Jensen
- Centre for Human Brain Health, School of Psychology, University of Birmingham, Edgbaston, Birmingham, B15 2SA, United Kingdom
| | - Anna U Kowalczyk
- Centre for Human Brain Health, School of Psychology, University of Birmingham, Edgbaston, Birmingham, B15 2SA, United Kingdom.
| |
Collapse
|
43
|
Rea M, Boto E, Holmes N, Hill R, Osborne J, Rhodes N, Leggett J, Rier L, Bowtell R, Shah V, Brookes MJ. A 90-channel triaxial magnetoencephalography system using optically pumped magnetometers. Ann N Y Acad Sci 2022; 1517:107-124. [PMID: 36065147 PMCID: PMC9826099 DOI: 10.1111/nyas.14890] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Magnetoencephalography (MEG) measures the small magnetic fields generated by current flow in neural networks, providing a noninvasive metric of brain function. MEG is well established as a powerful neuroscientific and clinical tool. However, current instrumentation is hampered by cumbersome cryogenic field-sensing technologies. In contrast, MEG using optically pumped magnetometers (OPM-MEG) employs small, lightweight, noncryogenic sensors that provide data with higher sensitivity and spatial resolution, a natural scanning environment (including participant movement), and adaptability to any age. However, OPM-MEG is new and the optimum way to design a system is unknown. Here, we construct a novel, 90-channel triaxial OPM-MEG system and use it to map motor function during a naturalistic handwriting task. Results show that high-precision magnetic field control reduced background fields to ∼200 pT, enabling free participant movement. Our triaxial array offered twice the total measured signal and better interference rejection compared to a conventional (single-axis) design. We mapped neural oscillatory activity to the sensorimotor network, demonstrating significant differences in motor network activity and connectivity for left-handed versus right-handed handwriting. Repeatability across scans showed that we can map electrophysiological activity with an accuracy ∼4 mm. Overall, our study introduces a novel triaxial OPM-MEG design and confirms its potential for high-performance functional neuroimaging.
Collapse
Affiliation(s)
- Molly Rea
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | - Elena Boto
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | - Ryan Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | | | - Natalie Rhodes
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | - James Leggett
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | - Lukas Rier
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| | | | - Matthew J. Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and AstronomyUniversity of NottinghamNottinghamUK
| |
Collapse
|
44
|
Pedersen M, Abbott DF, Jackson GD. Wearable OPM-MEG: A changing landscape for epilepsy. Epilepsia 2022; 63:2745-2753. [PMID: 35841260 PMCID: PMC9805039 DOI: 10.1111/epi.17368] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Revised: 07/13/2022] [Accepted: 07/14/2022] [Indexed: 01/09/2023]
Abstract
Magnetoencephalography with optically pumped magnometers (OPM-MEG) is an emerging and novel, cost-effective wearable system that can simultaneously record neuronal activity with high temporal resolution ("when" neuronal activity occurs) and spatial resolution ("where" neuronal activity occurs). This paper will first outline recent methodological advances in OPM-MEG compared to conventional superconducting quantum interference device (SQUID)-MEG before discussing how OPM-MEG can become a valuable and noninvasive clinical support tool in epilepsy surgery evaluation. Although OPM-MEG and SQUID-MEG share similar data features, OPM-MEG is a wearable design that fits children and adults, and it is also robust to head motion within a magnetically shielded room. This means that OPM-MEG can potentially extend the application of MEG into the neurobiology of severe childhood epilepsies with intellectual disabilities (e.g., epileptic encephalopathies) without sedation. It is worth noting that most OPM-MEG sensors are heated, which may become an issue with large OPM sensor arrays (OPM-MEG currently has fewer sensors than SQUID-MEG). Future implementation of triaxial sensors may alleviate the need for large OPM sensor arrays. OPM-MEG designs allowing both awake and sleep recording are essential for potential long-term epilepsy monitoring.
Collapse
Affiliation(s)
- Mangor Pedersen
- Department of Psychology and NeuroscienceAuckland University of TechnologyAucklandNew Zealand
| | - David F. Abbott
- Florey Institute of Neuroscience and Mental HealthMelbourneVictoriaAustralia,Department of Medicine, Austin Health and Florey Department of Neuroscience and Mental HealthUniversity of MelbourneMelbourneVictoriaAustralia
| | - Graeme D. Jackson
- Florey Institute of Neuroscience and Mental HealthMelbourneVictoriaAustralia,Department of Medicine, Austin Health and Florey Department of Neuroscience and Mental HealthUniversity of MelbourneMelbourneVictoriaAustralia
| |
Collapse
|
45
|
Tierney TM, Mellor S, O'Neill GC, Timms RC, Barnes GR. Spherical harmonic based noise rejection and neuronal sampling with multi-axis OPMs. Neuroimage 2022; 258:119338. [PMID: 35636738 PMCID: PMC10509822 DOI: 10.1016/j.neuroimage.2022.119338] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 05/04/2022] [Accepted: 05/26/2022] [Indexed: 10/18/2022] Open
Abstract
In this study we explore the interference rejection and spatial sampling properties of multi-axis Optically Pumped Magnetometer (OPM) data. We use both vector spherical harmonics and eigenspectra to quantify how well an array can separate neuronal signal from environmental interference while adequately sampling the entire cortex. We found that triaxial OPMs have superb noise rejection properties allowing for very high orders of interference (L=6) to be accounted for while minimally affecting the neural space (2dB attenuation for a 60-sensor triaxial system). We show that at least 11th order (143 spatial degrees of freedom) irregular solid harmonics or 95 eigenvectors of the lead field are needed to model the neural space for OPM data (regardless of number of axes measured). This can be adequately sampled with 75-100 equidistant triaxial sensors (225-300 channels) or 200 equidistant radial channels. In other words, ordering the same number of channels in triaxial (rather than purely radial) configuration may give significant advantages not only in terms of external noise rejection but also by minimizing cost, weight and cross-talk.
Collapse
Affiliation(s)
- Tim M Tierney
- Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, 12 Queen Square, London WC1N 3AR, UK.
| | - Stephanie Mellor
- Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, 12 Queen Square, London WC1N 3AR, UK
| | - George C O'Neill
- Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, 12 Queen Square, London WC1N 3AR, UK
| | - Ryan C Timms
- Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, 12 Queen Square, London WC1N 3AR, UK
| | - Gareth R Barnes
- Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, University College London, 12 Queen Square, London WC1N 3AR, UK
| |
Collapse
|
46
|
Brookes MJ, Leggett J, Rea M, Hill RM, Holmes N, Boto E, Bowtell R. Magnetoencephalography with optically pumped magnetometers (OPM-MEG): the next generation of functional neuroimaging. Trends Neurosci 2022; 45:621-634. [PMID: 35779970 PMCID: PMC10465236 DOI: 10.1016/j.tins.2022.05.008] [Citation(s) in RCA: 97] [Impact Index Per Article: 32.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 05/06/2022] [Accepted: 05/24/2022] [Indexed: 10/17/2022]
Abstract
Magnetoencephalography (MEG) measures human brain function via assessment of the magnetic fields generated by electrical activity in neurons. Despite providing high-quality spatiotemporal maps of electrophysiological activity, current MEG instrumentation is limited by cumbersome field sensing technologies, resulting in major barriers to utility. Here, we review a new generation of MEG technology that is beginning to lift many of these barriers. By exploiting quantum sensors, known as optically pumped magnetometers (OPMs), 'OPM-MEG' has the potential to dramatically outperform the current state of the art, promising enhanced data quality (better sensitivity and spatial resolution), adaptability to any head size/shape (from babies to adults), motion robustness (participants can move freely during scanning), and a less complex imaging platform (without reliance on cryogenics). We discuss the current state of this emerging technique and describe its far-reaching implications for neuroscience.
Collapse
Affiliation(s)
- Matthew J Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK.
| | - James Leggett
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Molly Rea
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Ryan M Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Elena Boto
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| |
Collapse
|
47
|
Integrated Polarization-Splitting Grating Coupler for Chip-Scale Atomic Magnetometer. BIOSENSORS 2022; 12:bios12070529. [PMID: 35884332 PMCID: PMC9313279 DOI: 10.3390/bios12070529] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 07/13/2022] [Accepted: 07/13/2022] [Indexed: 01/20/2023]
Abstract
Atomic magnetometers (AMs) are widely acknowledged as one of the most sensitive kind of instruments for bio-magnetic field measurement. Recently, there has been growing interest in developing chip-scale AMs through nanophotonics and current CMOS-compatible nanofabrication technology, in pursuit of substantial reduction in volume and cost. In this study, an integrated polarization-splitting grating coupler is demonstrated to achieve both efficient coupling and polarization splitting at the D1 transition wavelength of rubidium (795 nm). With this device, linearly polarized probe light that experienced optical rotation due to magnetically induced circular birefringence (of alkali medium) can be coupled and split into individual output ports. This is especially advantageous for emerging chip-scale AMs in that differential detection of ultra-weak magnetic field can be achieved through compact planar optical components. In addition, the device is designed with silicon nitride material on silicon dioxide that is deposited on a silicon substrate, being compatible with the current CMOS nanofabrication industry. Our study paves the way for the development of on-chip AMs that are the foundation for future multi-channel high-spatial resolution bio-magnetic imaging instruments.
Collapse
|
48
|
Nugent AC, Benitez Andonegui A, Holroyd T, Robinson SE. On-scalp magnetocorticography with optically pumped magnetometers: Simulated performance in resolving simultaneous sources. NEUROIMAGE. REPORTS 2022; 2:100093. [PMID: 35692456 PMCID: PMC9186482 DOI: 10.1016/j.ynirp.2022.100093] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Currently, the gold standard for high-resolution mapping of cortical electrophysiological activity is invasive electrocorticography (ECoG), a procedure that carries with it the risk of serious morbidity and mortality. Due to these risks, the use of ECoG is largely limited to pre-surgical mapping in intractable epilepsy. Nevertheless, many seminal studies in neuroscience have utilized ECoG to explore domains such as visual perception, attention, auditory processing, and sensorimotor behavior. Studies such as these, occurring in patients with epilepsy rather than healthy controls, may lack generalizability, and are limited by the placement of the electrode arrays over the presumed seizure focus. This manuscript explores the use of optically pumped magnetometers (OPMs) to create a non-invasive alternative to ECoG, which we refer to as magnetocorticography. Because prior ECoG studies reveal that most cognitive processes are driven by multiple, simultaneous independent neuronal assemblies, we characterize the ability of a theoretical 56-channel dense OPM array to resolve simultaneous independent sources, and compare it to currently available SQUID devices, as well as OPM arrays with inter-sensor spacings more typical of other systems in development. Our evaluation of this theoretical system assesses many potential sources of error, including errors of sensor calibration and position. In addition, we investigate the influence of geometrical and anatomical factors on array performance. Our simulations reveal the potential of high-density, on-scalp OPM MEG devices to localize electrophysiological brain responses at unprecedented resolution for a non-invasive device.
Collapse
|
49
|
Marhl U, Sander T, Jazbinšek V. Simulation Study of Different OPM-MEG Measurement Components. SENSORS 2022; 22:s22093184. [PMID: 35590874 PMCID: PMC9105726 DOI: 10.3390/s22093184] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 04/15/2022] [Accepted: 04/20/2022] [Indexed: 02/04/2023]
Abstract
Magnetoencephalography (MEG) is a neuroimaging technique that measures the magnetic fields of the brain outside of the head. In the past, the most suitable magnetometer for MEG was the superconducting quantum interference device (SQUID), but in recent years, a new type has also been used, the optically pumped magnetometer (OPM). OPMs can be configured to measure multiple directions of magnetic field simultaneously. This work explored whether combining multiple directions of the magnetic field lowers the source localization error of brain sources under various conditions of noise. We simulated dipolar-like sources for multiple configurations of both SQUID- and OPM-MEG systems. To test the performance of a given layout, we calculated the average signal-to-noise ratio and the root mean square of the simulated magnetic field; furthermore, we evaluated the performance of the dipole fit. The results showed that the field direction normal to the scalp yields a higher signal-to-noise ratio and that ambient noise has a much lower impact on its localization error; therefore, this is the optimal choice for source localization when only one direction of magnetic field can be measured. For a low number of OPMs, combining multiple field directions greatly improves the source localization results. Lastly, we showed that MEG sensors that can be placed closer to the brain are more suitable for localizing deeper sources.
Collapse
Affiliation(s)
- Urban Marhl
- Faculty of Natural Sciences and Mathematics, University of Maribor, Koroška cesta 160, 2000 Maribor, Slovenia
- Department of Physics, Institute of Mathematics, Physics and Mechanics, Jadranska ulica 19, 1000 Ljubljana, Slovenia;
- Correspondence:
| | - Tilmann Sander
- Physikalisch-Technische Bundesanstalt, Abbestraße 2, 10587 Berlin, Germany;
| | - Vojko Jazbinšek
- Department of Physics, Institute of Mathematics, Physics and Mechanics, Jadranska ulica 19, 1000 Ljubljana, Slovenia;
| |
Collapse
|
50
|
Zahran S, Mahmoudzadeh M, Wallois F, Betrouni N, Derambure P, Le Prado M, Palacios-Laloy A, Labyt E. Performance Analysis of Optically Pumped 4He Magnetometers vs. Conventional SQUIDs: From Adult to Infant Head Models. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22083093. [PMID: 35459077 PMCID: PMC9024855 DOI: 10.3390/s22083093] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 03/30/2022] [Accepted: 04/08/2022] [Indexed: 05/27/2023]
Abstract
Optically pumped magnetometers (OPMs) are new, room-temperature alternatives to superconducting quantum interference devices (SQUIDs) for measuring the brain's magnetic fields. The most used OPM in MagnetoEncephaloGraphy (MEG) are based on alkali atoms operating in the spin-exchange relaxation-free (SERF) regime. These sensors do not require cooling but have to be heated. Another kind of OPM, based on the parametric resonance of 4He atoms are operated at room temperature, suppressing the heat dissipation issue. They also have an advantageous bandwidth and dynamic range more suitable for MEG recordings. We quantitatively assessed the improvement (relative to a SQUID magnetometers array) in recording the magnetic field with a wearable 4He OPM-MEG system through data simulations. The OPM array and magnetoencephalography forward models were based on anatomical MRI data from an adult, a nine-year-old child, and 10 infants aged between one month and two years. Our simulations showed that a 4He OPMs array offers markedly better spatial specificity than a SQUID magnetometers array in various key performance areas (e.g., signal power, information content, and spatial resolution). Our results are also discussed regarding previous simulation results obtained for alkali OPM.
Collapse
Affiliation(s)
- Saeed Zahran
- INSERM, U1105, GRAMFC, Université de Picardie Jules Verne, CHU Sud, 80000 Amiens, France; (S.Z.); (M.M.); (F.W.)
| | - Mahdi Mahmoudzadeh
- INSERM, U1105, GRAMFC, Université de Picardie Jules Verne, CHU Sud, 80000 Amiens, France; (S.Z.); (M.M.); (F.W.)
| | - Fabrice Wallois
- INSERM, U1105, GRAMFC, Université de Picardie Jules Verne, CHU Sud, 80000 Amiens, France; (S.Z.); (M.M.); (F.W.)
| | - Nacim Betrouni
- INSERM, U1172, CHU de Lille, Université de Lille, Degenerative & Vascular Cognitive Disorders, 59000 Lille, France; (N.B.); (P.D.)
| | - Philippe Derambure
- INSERM, U1172, CHU de Lille, Université de Lille, Degenerative & Vascular Cognitive Disorders, 59000 Lille, France; (N.B.); (P.D.)
| | - Matthieu Le Prado
- Laboratoire d’Electronique et de Technologies de l’Information, CEA, 38054 Grenoble, France; (M.L.P.); (A.P.-L.)
- Mag4health, 9 Avenue Paul Verlaine, 38000 Grenoble, France
| | - Agustin Palacios-Laloy
- Laboratoire d’Electronique et de Technologies de l’Information, CEA, 38054 Grenoble, France; (M.L.P.); (A.P.-L.)
| | - Etienne Labyt
- Laboratoire d’Electronique et de Technologies de l’Information, CEA, 38054 Grenoble, France; (M.L.P.); (A.P.-L.)
- CEA Tech Hauts de France, 59000 Lille, France
| |
Collapse
|