Zong H, Yurdakul C, Zhao J, Wang Z, Chen F, Ünlü MS, Cheng JX. Bond-selective full-field optical coherence tomography. OPTICS EXPRESS 2023; 31:41202-41218. [PMID: 38087525 DOI: 10.1364/oe.503861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 11/10/2023] [Indexed: 12/18/2023]
Abstract
Optical coherence tomography (OCT) is a label-free, non-invasive 3D imaging tool widely used in both biological research and clinical diagnosis. Conventional OCT modalities can only visualize specimen tomography without chemical information. Here, we report a bond-selective full-field OCT (BS-FF-OCT), in which a pulsed mid-infrared laser is used to modulate the OCT signal through the photothermal effect, achieving label-free bond-selective 3D sectioned imaging of highly scattering samples. We first demonstrate BS-FF-OCT imaging of 1 µm PMMA beads embedded in agarose gel. Next, we show 3D hyperspectral imaging of up to 75 µm of polypropylene fiber mattress from a standard surgical mask. We then demonstrate BS-FF-OCT imaging on biological samples, including cancer cell spheroids and C. elegans. Using an alternative pulse timing configuration, we finally demonstrate the capability of BS-FF-OCT on imaging a highly scattering myelinated axons region in a mouse brain tissue slice.
Collapse
|
2
|
Ni J, Hong H, Zhang Y, Tang S, Han Y, Fang Z, Zhang Y, Zhou N, Wang Q, Liu Y, Li Z, Wang Y, Dong M. Development of a non-invasive method for skin cholesterol detection: pre-clinical assessment in atherosclerosis screening. Biomed Eng Online 2021; 20:52. [PMID: 34074299 PMCID: PMC8170999 DOI: 10.1186/s12938-021-00889-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 05/18/2021] [Indexed: 12/17/2022] Open
Abstract
Background Establishing a high-accuracy and non-invasive method is essential for evaluating cardiovascular disease. Skin cholesterol is a novel marker for assessing the risk of atherosclerosis and can be used as an independent risk factor of early assessment of atherosclerotic risk. Methods We propose a non-invasive skin cholesterol detection method based on absorption spectroscopy. Detection reagents specifically bind to skin cholesterol and react with indicator to produce colored products, the skin cholesterol content can be obtained through absorption spectrum information on colored products detected by non-invasive technology. Gas chromatography is used to measure cholesterol extracted from the skin to verify the accuracy and reliability of the non-invasive test method. A total of 342 subjects were divided into normal group (n = 115), disease group (n = 110) and risk group (n = 117). All subjects underwent non-invasive skin cholesterol test. The diagnostic accuracy of the measured value was analyzed by receiver-operating characteristic (ROC) curve. Results The proposed method is able to identify porcine skin containing gradient concentration of cholesterol. The values measured by non-invasive detection method were significantly correlated with gas chromatography measured results (r = 0.9074, n = 73, p < 0.001). Bland–Altman bias was − 72.78 ± 20.03 with 95% limits of agreement − 112.05 to − 33.51, falling within the prespecified clinically non-significant range. We further evaluated the method of patients with atherosclerosis and risk population as well as normal group, patients and risk atherosclerosis group exhibited higher skin cholesterol content than normal group (all P < 0.001). The area under the ROC curve for distinguishing Normal/Disease group was 0.8642 (95% confidence interval, 0.8138 to 0.9146), meanwhile, the area under the ROC curve for distinguishing Normal/Risk group was 0.8534 (95% confidence interval, 0.8034 to 0.9034). Conclusions The method demonstrated its capability of detecting different concentration of skin cholesterol. This non-invasive skin cholesterol detection system may potentially be used as a risk assessment tool for atherosclerosis screening, especially for a large population. Supplementary Information The online version contains supplementary material available at 10.1186/s12938-021-00889-1.
Collapse
Affiliation(s)
- Jingshu Ni
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science , Chinese Academy of Sciences, Hefei, 230031, China.,University of Science and Technology of China, Hefei, 230026, China
| | - Haiou Hong
- Health Management Center, First Affiliated Hospital of University of Science and Technology of China, Hefei, China
| | - Yang Zhang
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science , Chinese Academy of Sciences, Hefei, 230031, China.,University of Science and Technology of China, Hefei, 230026, China
| | - Shiqi Tang
- Health Management Center, Renmin Hospital of WuHan University, Wuhan, 430060, China
| | - Yongsheng Han
- Department of Cardiovascular Medicine, First Affiliated Hospital of University of Science and Technology of China, Hefei, 230001, China
| | - Zhaohui Fang
- Department of Endocrinology, The First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Hefei, 230031, China
| | - Yuanzhi Zhang
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science , Chinese Academy of Sciences, Hefei, 230031, China.,Wanjiang Center for Development of Emerging Industrial Technology, Tongling, 244000, China
| | - Nan Zhou
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science , Chinese Academy of Sciences, Hefei, 230031, China.,Wanjiang Center for Development of Emerging Industrial Technology, Tongling, 244000, China
| | - Quanfu Wang
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science , Chinese Academy of Sciences, Hefei, 230031, China.,Wanjiang Center for Development of Emerging Industrial Technology, Tongling, 244000, China
| | - Yong Liu
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science , Chinese Academy of Sciences, Hefei, 230031, China.,University of Science and Technology of China, Hefei, 230026, China.,Wanjiang Center for Development of Emerging Industrial Technology, Tongling, 244000, China
| | - Zhongsheng Li
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science , Chinese Academy of Sciences, Hefei, 230031, China
| | - YiKun Wang
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science , Chinese Academy of Sciences, Hefei, 230031, China. .,University of Science and Technology of China, Hefei, 230026, China.
| | - Meili Dong
- Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science , Chinese Academy of Sciences, Hefei, 230031, China. .,University of Science and Technology of China, Hefei, 230026, China.
| |
Collapse
|
3
|
Mayerhöfer TG, Pahlow S, Popp J. Recent technological and scientific developments concerning the use of infrared spectroscopy for point-of-care applications. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 251:119411. [PMID: 33450450 DOI: 10.1016/j.saa.2020.119411] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 12/27/2020] [Accepted: 12/29/2020] [Indexed: 06/12/2023]
Abstract
In this contribution we review selected point-of-care applications of infrared spectroscopy and the technological innovations they are based on. After a short introduction summarizing the general idea behind point-of-care applications we introduce the reader to important infrared spectroscopy sensing principles on a very basic level. We discuss the role of optical components like quantum cascade lasers, supercontinuum sources, waveguides and how they are potentially going to revolutionize point-of-care applications. First, we focus on the technological solutions of some principal problems like increasing the pathlength in a transmission cell to enhance the sensitivity for solutes in aqueous solutions and discuss indirect methods which circumvent the problem of low transmittance. In the second part we show how the technological progress of the last decades enabled scientific progress leading to selected concrete and outstanding point-of-care solutions and applications based on infrared spectroscopy. These include the detection and quantification of malaria parasitemia, early recognition of Alzheimer's disease long before the onset of clinical symptoms and a non-invasive method for testing the blood glucose content. The selected examples demonstrate and showcase that infrared spectroscopy is on the way to become an indispensable technique for point-of-care applications.
Collapse
Affiliation(s)
- Thomas G Mayerhöfer
- Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Str. 9, D-07745 Jena, Germany; Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Jena, D-07743, Helmholtzweg 4, Germany
| | - Susanne Pahlow
- Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Str. 9, D-07745 Jena, Germany; Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Jena, D-07743, Helmholtzweg 4, Germany
| | - Jürgen Popp
- Leibniz Institute of Photonic Technology (IPHT), Albert-Einstein-Str. 9, D-07745 Jena, Germany; Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Jena, D-07743, Helmholtzweg 4, Germany.
| |
Collapse
|
4
|
Kim SJ, Lee HJ, Lee JH, Oh H, Park S, Lim DH, Park MS, Lee JB. In vivo determination of the Infrared-A protection factor on human skin. Skin Res Technol 2021; 27:814-823. [PMID: 33665925 DOI: 10.1111/srt.13026] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 02/13/2021] [Indexed: 01/22/2023]
Abstract
BACKGROUND Chronic exposure to infrared A (IR-A) irradiation causes photoaging. However, daily or acute exposure to IR-A rarely induces erythema or pigmentation. Thus, evaluation of the physiological changes taking place on the skin surface is insufficient for clinical investigations. MATERIALS AND METHODS We fabricated a novel device to obtain the IR-A protection factor (IPF) on human skin. This device consists of an artificial light source that mimics the actual IR-A intensity of sunlight, and a spectrophotometer to measure the spectral reflectance on the skin surface. The IPF can be determined by measuring the difference in spectral reflectance on the skin before and after the use of products and can be verified by the statistical criterion. A validation study was performed using different light intensities and two experimenters. Finally, we monitored the IPF on 12 commercial cosmetics. RESULTS After considering the IPF and L*-values, we selected the optimal sample and performed a validation study. Neither the intensity of IR-A irradiation or the experimenters significantly affected the IPF. 12 commercial products exhibited their own IPF values and were verified by statistical criteria, with one exception. CONCLUSION The present IPF evaluation method was concluded to be robust and reliable. This method is simple and safe for the subjects, and could be helpful for the development of IR-A protection products and the confirmation of product performances.
Collapse
|
5
|
Heise HM, Delbeck S, Marbach R. Noninvasive Monitoring of Glucose Using Near-Infrared Reflection Spectroscopy of Skin-Constraints and Effective Novel Strategy in Multivariate Calibration. BIOSENSORS 2021; 11:bios11030064. [PMID: 33673679 PMCID: PMC7997402 DOI: 10.3390/bios11030064] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Revised: 02/22/2021] [Accepted: 02/23/2021] [Indexed: 05/10/2023]
Abstract
For many years, successful noninvasive blood glucose monitoring assays have been announced, among which near-infrared (NIR) spectroscopy of skin is a promising analytical method. Owing to the tiny absorption bands of the glucose buried among a dominating variable spectral background, multivariate calibration is required to achieve applicability for blood glucose self-monitoring. The most useful spectral range with important analyte fingerprint signatures is the NIR spectral interval containing combination and overtone vibration band regions. A strategy called science-based calibration (SBC) has been developed that relies on a priori information of the glucose signal ("response spectrum") and the spectral noise, i.e., estimates of the variance of a sample population with negligible glucose dynamics. For the SBC method using transcutaneous reflection skin spectra, the response spectrum requires scaling due to the wavelength-dependent photon penetration depth, as obtained by Monte Carlo simulations of photon migration based on estimates of optical tissue constants. Results for tissue glucose concentrations are presented using lip NIR-spectra of a type-1 diabetic subject recorded under modified oral glucose tolerance test (OGTT) conditions. The results from the SBC method are extremely promising, as statistical calibrations show limitations under the conditions of ill-posed equation systems as experienced for tissue measurements. The temporal profile differences between the glucose concentration in blood and skin tissue were discussed in detail but needed to be further evaluated.
Collapse
Affiliation(s)
- H. Michael Heise
- Interdisciplinary Center for Life Sciences, South-Westphalia University of Applied Sciences, Frauenstuhlweg 31, 58644 Iserlohn, Germany;
- Correspondence: ; Tel.: +49-2371-566412
| | - Sven Delbeck
- Interdisciplinary Center for Life Sciences, South-Westphalia University of Applied Sciences, Frauenstuhlweg 31, 58644 Iserlohn, Germany;
| | - Ralf Marbach
- CLAAS Selbstfahrende Erntemaschinen, Muehlenwinkel 1, 33428 Harsewinkel, Germany;
| |
Collapse
|
6
|
Delbeck S, Heise HM. Evaluation of Opportunities and Limitations of Mid-Infrared Skin Spectroscopy for Noninvasive Blood Glucose Monitoring. J Diabetes Sci Technol 2021; 15:19-27. [PMID: 32590911 PMCID: PMC7780363 DOI: 10.1177/1932296820936224] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
BACKGROUND A wide range of optical techniques has recently been presented for the development of noninvasive methods for blood glucose sensing based on multivariate skin spectrum analysis, and most recent studies are reviewed in short by us. The vibrational spectral fingerprints of glucose, as especially found in the mid-infrared or Raman spectrum, have been suggested for achieving largest selectivity for the development of noninvasive blood glucose methods. METHODS Here, the different aspects on integral skin measurements are presented, which are much dependent on the absorption characteristics of water as the main skin constituent. In particular, different mid-infrared measurement techniques as realized recently are discussed. The limitations of the use of the attenuated total reflection technique in particular are elaborated, and confounding skin or saliva spectral features are illustrated and discussed in the light of recently published works, claiming that the attenuated total reflection technique can be utilized for noninvasive measurements. RESULTS It will be shown that the penetration depth of the infrared radiation with wavelengths around 10 µm is the essential parameter, which can be modulated by different measurement techniques as with photothermal or diffuse reflection. However, the law of physics is limiting the option of using the attenuated total reflection technique with waveguides from diamond or similar optical materials. CONCLUSIONS There are confounding features from mucosa, stratum corneum, or saliva, which have been misinterpreted for glucose measurements. Results of an earlier study with multivariate evaluation based on glucose fingerprint features are again referred to as a negative experimental proof.
Collapse
Affiliation(s)
- Sven Delbeck
- South-Westphalia University of Applied Sciences, Interdisciplinary Center for Life Sciences, Iserlohn, Germany
| | - H. Michael Heise
- South-Westphalia University of Applied Sciences, Interdisciplinary Center for Life Sciences, Iserlohn, Germany
- H. Michael Heise, PhD, South-Westphalia University of Applied Sciences, Interdisciplinary Center for Life Sciences, Frauenstuhlweg 31, D-58644 Iserlohn, Germany.
| |
Collapse
|
7
|
Rassel S, Xu C, Zhang S, Ban D. Noninvasive blood glucose detection using a quantum cascade laser. Analyst 2020; 145:2441-2456. [PMID: 32167098 DOI: 10.1039/c9an02354b] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A Quantum Cascade Laser (QCL) was invented in the late 90s as a promising mid-infrared light source and it has contributed to the fields of industry, military, medicine, and biology. The room temperature operation, watt-level output power, compact size, and wide tuning capability of this laser advanced the field of noninvasive blood glucose detection with the use of transmission, absorption, and photoacoustic spectroscopy. This review provides a complete overview of the recent progress and technical details of these spectroscopy techniques, using QCL as an infrared light source for detecting blood glucose concentrations in diabetic patients.
Collapse
Affiliation(s)
- Shazzad Rassel
- Waterloo Institute for Nanotechnology and Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada.
| | | | | | | |
Collapse
|
8
|
Pena AM, Chen X, Pence IJ, Bornschlögl T, Jeong S, Grégoire S, Luengo GS, Hallegot P, Obeidy P, Feizpour A, Chan KF, Evans CL. Imaging and quantifying drug delivery in skin - Part 2: Fluorescence andvibrational spectroscopic imaging methods. Adv Drug Deliv Rev 2020; 153:147-168. [PMID: 32217069 PMCID: PMC7483684 DOI: 10.1016/j.addr.2020.03.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2019] [Revised: 03/10/2020] [Accepted: 03/18/2020] [Indexed: 01/31/2023]
Abstract
Understanding the delivery and diffusion of topically-applied drugs on human skin is of paramount importance in both pharmaceutical and cosmetics research. This information is critical in early stages of drug development and allows the identification of the most promising ingredients delivered at optimal concentrations to their target skin compartments. Different skin imaging methods, invasive and non-invasive, are available to characterize and quantify the spatiotemporal distribution of a drug within ex vivo and in vivo human skin. The first part of this review detailed invasive imaging methods (autoradiography, MALDI and SIMS). This second part reviews non-invasive imaging methods that can be applied in vivo: i) fluorescence (conventional, confocal, and multiphoton) and second harmonic generation microscopies and ii) vibrational spectroscopic imaging methods (infrared, confocal Raman, and coherent Raman scattering microscopies). Finally, a flow chart for the selection of imaging methods is presented to guide human skin ex vivo and in vivo drug delivery studies.
Collapse
Affiliation(s)
- Ana-Maria Pena
- L'Oréal Research and Innovation, 1 avenue Eugène Schueller BP22, 93600 Aulnay-sous-Bois, France
| | - Xueqin Chen
- L'Oréal Research and Innovation, 1 avenue Eugène Schueller BP22, 93600 Aulnay-sous-Bois, France
| | - Isaac J Pence
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, CNY149-3, 13(th) St, Charlestown, MA 02129, United States of America
| | - Thomas Bornschlögl
- L'Oréal Research and Innovation, 1 avenue Eugène Schueller BP22, 93600 Aulnay-sous-Bois, France
| | - Sinyoung Jeong
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, CNY149-3, 13(th) St, Charlestown, MA 02129, United States of America
| | - Sébastien Grégoire
- L'Oréal Research and Innovation, 1 avenue Eugène Schueller BP22, 93600 Aulnay-sous-Bois, France.
| | - Gustavo S Luengo
- L'Oréal Research and Innovation, 1 avenue Eugène Schueller BP22, 93600 Aulnay-sous-Bois, France
| | - Philippe Hallegot
- L'Oréal Research and Innovation, 1 avenue Eugène Schueller BP22, 93600 Aulnay-sous-Bois, France
| | - Peyman Obeidy
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, CNY149-3, 13(th) St, Charlestown, MA 02129, United States of America
| | - Amin Feizpour
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, CNY149-3, 13(th) St, Charlestown, MA 02129, United States of America
| | - Kin F Chan
- Simpson Interventions, Inc., Woodside, CA 94062, United States of America
| | - Conor L Evans
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, CNY149-3, 13(th) St, Charlestown, MA 02129, United States of America.
| |
Collapse
|
9
|
Kim SJ, Bae J, Lee SE, Lee JB, Park CH, Lim DH, Park MS, Ha J. A novel in vivo test method for evaluating the infrared radiation protection provided by sunscreen products. Skin Res Technol 2019; 25:890-895. [PMID: 31338921 DOI: 10.1111/srt.12754] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Accepted: 06/27/2019] [Indexed: 01/28/2023]
Abstract
BACKGROUND Infrared radiation (IR) exposure generates reactive oxygen species and induces matrix metalloproteinase-1 expression in human skin. Moreover, while not as acute as ultraviolet radiation, repeated infrared irradiation can result in the photoaging of skin. Broad-spectrum sunscreens can protect skin from IR, but no human in vivo test methods for the evaluation of sunscreens' IR protection effect have been developed. We aimed to develop such a method. MATERIALS AND METHODS We included 155 Korean subjects in our three-part clinical study. The IR reflectance of subjects' skin was measured using a benchtop model of an IR light source and a reflectance measuring probe. We measured the IR reflectance in relation to skin color and hydration level to set up our experimental conditions. We then calculated the infrared protection factors (IPFs) of cosmetic emulsions as the IR reflectance ratio between cosmetic sunscreen-applied skin and non-sunscreen-applied skin and assessed the relationship between IPFs and the amount of sunscreen ingredients. Finally, this method was validated using several commercial sunscreen cosmetics. RESULTS Skin color and hydration level did not influence the IR reflectance of subjects' skin. The IPFs of cosmetic sunscreens showed a positive correlation with the amount of inorganic sunscreen ingredients. CONCLUSION In this study, we developed a simple, fast, and ethically acceptable human in vivo test method for evaluating the IPFs of cosmetic sunscreens.
Collapse
Affiliation(s)
- Su Ji Kim
- Cosmax Inc, Bundang-gu, Seongnam, Korea
| | - Jiyoun Bae
- I.E.C. Korea, Yeongtong-gu, Suwon, Korea
| | | | | | | | | | | | | |
Collapse
|
10
|
Schwaighofer A, Brandstetter M, Lendl B. Quantum cascade lasers (QCLs) in biomedical spectroscopy. Chem Soc Rev 2017; 46:5903-5924. [DOI: 10.1039/c7cs00403f] [Citation(s) in RCA: 102] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
This review focuses on the recent applications of QCLs in mid-IR spectroscopy of clinically relevant samples.
Collapse
Affiliation(s)
- Andreas Schwaighofer
- Institute of Chemical Technologies and Analytics
- Vienna University of Technology
- 1060 Vienna
- Austria
| | | | - Bernhard Lendl
- Institute of Chemical Technologies and Analytics
- Vienna University of Technology
- 1060 Vienna
- Austria
| |
Collapse
|