1
|
Rozman M, Lukšič M. Electrode Materials for Flexible Electrochromics. Int J Mol Sci 2025; 26:3260. [PMID: 40244101 PMCID: PMC11989306 DOI: 10.3390/ijms26073260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2025] [Revised: 03/27/2025] [Accepted: 03/28/2025] [Indexed: 04/18/2025] Open
Abstract
Flexible electrochromic devices (ECDs) represent a distinctive category in optoelectronics, leveraging advanced materials to achieve tunable coloration under applied electric voltage. This review delves into recent advancements in electrode materials for ECDs, with a focus on silver nanowires, metal meshes, conductive polymers, carbon nanotubes, and transparent conductive ceramics. Each material is evaluated based on its manufacturing methods and integration potential. The analysis highlights the prominent role of transparent conductive ceramics and conductive polymers due to their versatility and scalability, while also addressing challenges such as environmental stability and production costs. Use of other alternative materials, such as metal meshes, carbon materials, nanowires and others, are presented here as a comparison as well. Emerging hybrid systems and advanced coating techniques are identified as promising solutions to overcome limitations regarding flexibility and durability. This review underscores the critical importance of electrode innovation in enhancing the performance, sustainability, and application scope of flexible ECDs for next-generation technologies.
Collapse
Affiliation(s)
- Martin Rozman
- Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia;
| | | |
Collapse
|
2
|
Pourmostafa A, Bhusal A, Haridas Menon N, Li Z, Basuray S, Miri AK. Integrating conductive electrodes into hydrogel-based microfluidic chips for real-time monitoring of cell response. Front Bioeng Biotechnol 2024; 12:1421592. [PMID: 39257447 PMCID: PMC11384590 DOI: 10.3389/fbioe.2024.1421592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Accepted: 07/31/2024] [Indexed: 09/12/2024] Open
Abstract
The conventional real-time screening in organs-on-chips is limited to optical tracking of pre-tagged cells and biological agents. This work introduces an efficient biofabrication protocol to integrate tunable hydrogel electrodes into 3D bioprinted-on-chips. We established our method of fabricating cell-laden hydrogel-based microfluidic chips through digital light processing-based 3D bioprinting. Our conductive ink includes poly-(3,4-ethylene-dioxythiophene)-polystyrene sulfonate (PEDOT: PSS) microparticles doped in polyethylene glycol diacrylate (PEGDA). We optimized the manufacturing process of PEDOT: PSS microparticles characterized our conductive ink for different 3D bioprinting parameters, geometries, and materials conditions. While the literature is limited to 0.5% w/v for PEDOT: PSS microparticle concentration, we increased their concentration to 5% w/v with superior biological responses. We measured the conductivity in the 3-15 m/m for a range of 0.5%-5% w/v microparticles, and we showed the effectiveness of 3D-printed electrodes for predicting cell responses when encapsulated in gelatin-methacryloyl (GelMA). Interestingly, a higher cellular activity was observed in the case of 5% w/v microparticles compared to 0.5% w/v microparticles. Electrochemical impedance spectroscopy measurements indicated significant differences in cell densities and spheroid sizes embedded in GelMA microtissues.
Collapse
Affiliation(s)
- Ayda Pourmostafa
- Department of Biomedical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Newark, NJ, United States
| | - Anant Bhusal
- Department of Mechanical Engineering, Rowan University, Glassboro, NJ, United States
| | - Niranjan Haridas Menon
- Department of Chemical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Glassboro, Newark, NJ, United States
| | - Zhenglong Li
- Department of Chemical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Glassboro, Newark, NJ, United States
| | - Sagnik Basuray
- Department of Chemical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Glassboro, Newark, NJ, United States
| | - Amir K Miri
- Department of Biomedical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Newark, NJ, United States
| |
Collapse
|
3
|
Hossain MS, Khaleque MA, Ali MR, Bacchu MS, Hossain MI, Aly Saad Aly M, Khan MZH. Poly(3,4-ethylenedioxythiophene):Polystyrene Sulfonate-Modified Electrode for the Detection of Furosemide in Pharmaceutical Products. ACS OMEGA 2023; 8:16851-16858. [PMID: 37214665 PMCID: PMC10193417 DOI: 10.1021/acsomega.3c00463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Accepted: 04/19/2023] [Indexed: 05/24/2023]
Abstract
Furosemide (4-chloro-2-(furan-2-ylmethylamino)-5-sulfamoyl benzoic acid) is a widely used, FDA-approved drug prescribed for several symptoms associated with heart, kidney, liver failure, or chronic high blood pressure. In this work, a glassy carbon working electrode modified with poly(3,4-ethylenedioxythiophene):polystyrene sulfonate is developed to detect furosemide (FURO) with high sensitivity and precise selectivity. The modified electrode was also characterized using field emission scanning electron microscopy, attenuated total reflectance-Fourier transform infrared, and cyclic voltammetry. Here, an efficient and cost- and time-efficient technique to study the furosemide mechanism of reaction in an acidic liquid medium is presented. An electrochemical oxidation of loop diuretic furosemide was investigated in a supporting electrolyte, 0.01 M of phosphate buffer (at a pH level of 4.0) at 25 ± 0.1 °C using a differential pulse voltammetric (DPV) technique. Under optimized parameters, the developed sensor displays a wide detection range of furosemide concentrations of 6.0 × 10-6 to 1.0 × 10-4 M with a detection limit of 2.0 × 10-6 M using DPV. The presented sensor offers a robust and high-precision technique with an excellent reproducibility to detect furosemide in as a real sample such as urine and pharmaceutical products.
Collapse
Affiliation(s)
- Md. Shamim Hossain
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Md. Abdul Khaleque
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Md. Romzan Ali
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Md. Sadek Bacchu
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Md. Ikram Hossain
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Mohamed Aly Saad Aly
- Department
of Electrical and Computer Engineering at Georgia Tech Shenzhen Institute
(GTSI), Tianjin University, Shenzhen, Guangdong 518052, China
| | - Md. Zaved Hossain Khan
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| |
Collapse
|
4
|
Mintz Hemed N, Leal-Ortiz S, Zhao ET, Melosh NA. On-Demand, Reversible, Ultrasensitive Polymer Membrane Based on Molecular Imprinting Polymer. ACS NANO 2023; 17:5632-5643. [PMID: 36913954 PMCID: PMC10062346 DOI: 10.1021/acsnano.2c11618] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 03/08/2023] [Indexed: 06/18/2023]
Abstract
The development of in vivo, longitudinal, real-time monitoring devices is an essential step toward continuous, precision health monitoring. Molecularly imprinted polymers (MIPs) are popular sensor capture agents that are more robust than antibodies and have been used for sensors, drug delivery, affinity separations, assays, and solid-phase extraction. However, MIP sensors are typically limited to one-time use due to their high binding affinity (>107 M-1) and slow-release kinetics (<10-4 μM/sec). To overcome this challenge, current research has focused on stimuli-responsive MIPs (SR-MIPs), which undergo a conformational change induced by external stimuli to reverse molecular binding, requiring additional chemicals or outside stimuli. Here, we demonstrate fully reversible MIP sensors based on electrostatic repulsion. Once the target analyte is bound within a thin film MIP on an electrode, a small electrical potential successfully releases the bound molecules, enabling repeated, accurate measurements. We demonstrate an electrostatically refreshed dopamine sensor with a 760 pM limit of detection, linear response profile, and accuracy even after 30 sensing-release cycles. These sensors could repeatedly detect <1 nM dopamine released from PC-12 cells in vitro, demonstrating they can longitudinally measure low concentrations in complex biological environments without clogging. Our work provides a simple and effective strategy for enhancing the use of MIPs-based biosensors for all charged molecules in continuous, real-time health monitoring and other sensing applications.
Collapse
Affiliation(s)
- Nofar Mintz Hemed
- Department
of Materials Science and Engineering, Stanford
University, Stanford, California 94305, United States
| | - Sergio Leal-Ortiz
- Department
of Psychiatry and Behavioral Sciences, Stanford
University, Stanford, California 94304, United States
| | - Eric T. Zhao
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
| | - Nicholas A. Melosh
- Department
of Materials Science and Engineering, Stanford
University, Stanford, California 94305, United States
| |
Collapse
|
5
|
All-solid-state potentiometric salicylic acid sensor for in-situ measurement of plant. Anal Bioanal Chem 2023; 415:1979-1989. [PMID: 36864309 DOI: 10.1007/s00216-023-04616-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 02/14/2023] [Accepted: 02/17/2023] [Indexed: 03/04/2023]
Abstract
Using PEDOT as the conductive polymer, an innovative small-scale sensor for directly measuring salicylate ions in plants was developed, which avoided the complicated sample pretreatment of traditional analytical methods and realized the rapid detection of salicylic acid. The results demonstrate that this all-solid-state potentiometric salicylic acid sensor is easy to miniaturize, has a longer lifetime (≥1 month), is more robust, and can be directly used for the detection of salicylate ions in real samples without any additional pretreatment. The developed sensor has a good Nernst slope (63.6 ± 0.7 mV/decade), the linear range is 10-2 ~ 10-6 M, and the detection limit can reach (2.8 × 10-7 M). The selectivity, reproducibility, and stability of the sensor were evaluated. The sensor can perform stable, sensitive, and accurate in situ measurement of salicylic acid in plants, and it is an excellent tool for determining salicylic acid ions in plants in vivo.
Collapse
|
6
|
Ahnood A, Chambers A, Gelmi A, Yong KT, Kavehei O. Semiconducting electrodes for neural interfacing: a review. Chem Soc Rev 2023; 52:1491-1518. [PMID: 36734845 DOI: 10.1039/d2cs00830k] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
In the past 50 years, the advent of electronic technology to directly interface with neural tissue has transformed the fields of medicine and biology. Devices that restore or even replace impaired bodily functions, such as deep brain stimulators and cochlear implants, have ushered in a new treatment era for previously intractable conditions. Meanwhile, electrodes for recording and stimulating neural activity have allowed researchers to unravel the vast complexities of the human nervous system. Recent advances in semiconducting materials have allowed effective interfaces between electrodes and neuronal tissue through novel devices and structures. Often these are unattainable using conventional metallic electrodes. These have translated into advances in research and treatment. The development of semiconducting materials opens new avenues in neural interfacing. This review considers this emerging class of electrodes and how it can facilitate electrical, optical, and chemical sensing and modulation with high spatial and temporal precision. Semiconducting electrodes have advanced electrically based neural interfacing technologies owing to their unique electrochemical and photo-electrochemical attributes. Key operation modalities, namely sensing and stimulation in electrical, biochemical, and optical domains, are discussed, highlighting their contrast to metallic electrodes from the application and characterization perspective.
Collapse
Affiliation(s)
- Arman Ahnood
- School of Engineering, RMIT University, VIC 3000, Australia
| | - Andre Chambers
- School of Physics, University of Melbourne, Melbourne, Victoria 3010, Australia
| | - Amy Gelmi
- School of Science, RMIT University, VIC 3000, Australia
| | - Ken-Tye Yong
- School of Biomedical Engineering, University of Sydney, Sydney, NSW 2006, Australia.,The University of Sydney Nano Institute, Sydney, NSW 2006, Australia.
| | - Omid Kavehei
- School of Biomedical Engineering, University of Sydney, Sydney, NSW 2006, Australia.,The University of Sydney Nano Institute, Sydney, NSW 2006, Australia.
| |
Collapse
|
7
|
Er E, Kemal Ateş A. Design of an electrochemical sensing platform based on MoS2-PEDOT:PSS nanocomposite for the detection of epirubicin in biological samples. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
|
8
|
Niederhoffer T, Vanhoestenberghe A, Lancashire HT. Methods of poly(3,4)-ethylenedioxithiophene (PEDOT) electrodeposition on metal electrodes for neural stimulation and recording. J Neural Eng 2023; 20. [PMID: 36603213 DOI: 10.1088/1741-2552/acb084] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 01/05/2023] [Indexed: 01/06/2023]
Abstract
Conductive polymers are of great interest in the field of neural electrodes because of their potential to improve the interfacial properties of electrodes. In particular, the conductive polymer poly (3,4)-ethylenedioxithiophene (PEDOT) has been widely studied for neural applications.Objective:This review compares methods for electrodeposition of PEDOT on metal neural electrodes, and analyses the effects of deposition methods on morphology and electrochemical performance.Approach:Electrochemical performances were analysed against several deposition method choices, including deposition charge density and co-ion, and correlations were explained to morphological and structural arguments as well as characterisation methods choices.Main results:Coating thickness and charge storage capacity are positively correlated with PEDOT electrodeposition charge density. We also show that PEDOT coated electrode impedance at 1 kHz, the only consistently reported impedance quantity, is strongly dependent upon electrode radius across a wide range of studies, because PEDOT coatings reduces the reactance of the complex impedance, conferring a more resistive behaviour to electrodes (at 1 kHz) dominated by the solution resistance and electrode geometry. This review also summarises how PEDOT co-ion choice affects coating structure and morphology and shows that co-ions notably influence the charge injection limit but have a limited influence on charge storage capacity and impedance. Finally we discuss the possible influence of characterisation methods to assess the robustness of comparisons between published results using different methods of characterisation.Significance:This review aims to serve as a common basis for researchers working with PEDOT by showing the effects of deposition methods on electrochemical performance, and aims to set a standard for accurate and uniform reporting of methods.
Collapse
Affiliation(s)
- Thomas Niederhoffer
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom
| | - Anne Vanhoestenberghe
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Henry T Lancashire
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom
| |
Collapse
|
9
|
Park SG, Rhee C, Jadhav DA, Eisa T, Al-Mayyahi RB, Shin SG, Abdelkareem MA, Chae KJ. Tailoring a highly conductive and super-hydrophilic electrode for biocatalytic performance of microbial electrolysis cells. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 856:159105. [PMID: 36181811 DOI: 10.1016/j.scitotenv.2022.159105] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 09/14/2022] [Accepted: 09/24/2022] [Indexed: 06/16/2023]
Abstract
Bioelectrochemical hydrogen production via microbial electrolysis cells (MECs) has attracted attention as the next generation of technology for the hydrogen economy. MECs work by electrochemically active bacteria reducing organic compounds at the anode. However, the hydrophobic nature of carbon-based anodes suppresses the release of the produced gas and water penetration, which significantly reduces the possibility of microbial attachment. Consequently, a limited surface area of the anode is used, which decreases hydrogen production efficiency. In this study, the bifunctional material poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) was applied to the surface of a three-dimensional carbon felt anode to enhance the hydrogen production efficiency of an MEC owing to the high conductivity of PEDOT and super-hydrophilicity of PSS. In experiments, the PEDOT:PSS-modified anode almost doubled the hydrogen production efficiency of the MEC compared with the control anode owing to the increased capacitance current (239.3 %) and biofilm formation (220.7 %). The modified anode reduced the time required for the MEC to reach a steady state of hydrogen production by 14 days compared to the control anode. Microbial community profiles demonstrated that the modified anode had a greater abundance of electrochemically active bacteria than the control anode. This simple method could be widely applied to various bioelectrochemical systems (e.g., microbial fuel cells and solar cells) and to scaling up MECs.
Collapse
Affiliation(s)
- Sung-Gwan Park
- Department of Environmental Engineering, College of Ocean Science and Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-gu, Busan 49112, Republic of Korea; Interdisciplinary Major of Ocean Renewable Energy Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-gu, Busan 49112, Republic of Korea
| | - Chaeyoung Rhee
- Department of Energy Engineering, Future Convergence Technology Research Institute, Gyeongsang National University, 501 Jinju-daero, Jinju, Gyeongnam 52828, Republic of Korea
| | - Dipak A Jadhav
- Department of Environmental Engineering, College of Ocean Science and Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-gu, Busan 49112, Republic of Korea
| | - Tasnim Eisa
- Department of Environmental Engineering, College of Ocean Science and Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-gu, Busan 49112, Republic of Korea; Interdisciplinary Major of Ocean Renewable Energy Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-gu, Busan 49112, Republic of Korea
| | - Riyam B Al-Mayyahi
- Department of Environmental Engineering, College of Ocean Science and Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-gu, Busan 49112, Republic of Korea; Interdisciplinary Major of Ocean Renewable Energy Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-gu, Busan 49112, Republic of Korea
| | - Seung Gu Shin
- Department of Energy Engineering, Future Convergence Technology Research Institute, Gyeongsang National University, 501 Jinju-daero, Jinju, Gyeongnam 52828, Republic of Korea
| | - Mohammad Ali Abdelkareem
- Chemical Engineering Department, Faculty of Engineering, Minia University, Minia, Egypt; Center of Advanced Materials Research, Research Institute of Science and Engineering, University of Sharjah, P.O. Box 27272, Sharjah, United Arab Emirates; Department of Sustainable and Renewable Energy Engineering, University of Sharjah, PO Box 27272, Sharjah, United Arab Emirates.
| | - Kyu-Jung Chae
- Department of Environmental Engineering, College of Ocean Science and Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-gu, Busan 49112, Republic of Korea; Interdisciplinary Major of Ocean Renewable Energy Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-gu, Busan 49112, Republic of Korea.
| |
Collapse
|
10
|
Bhaskara S, Sakorikar T, Chatterjee S, Shabari Girishan K, Pandya HJ. Recent advancements in Micro-engineered devices for surface and deep brain animal studies: A review. SENSING AND BIO-SENSING RESEARCH 2022. [DOI: 10.1016/j.sbsr.2022.100483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
11
|
Nde DT, Jhung SH, Lee HJ. Electrocatalytic Determination of Hydrazine Concentrations with Polyelectrolyte Supported AuCo Nanoparticles on Carbon Electrodes. Catal Today 2022. [DOI: 10.1016/j.cattod.2022.03.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
12
|
Functionalization Strategies of PEDOT and PEDOT:PSS Films for Organic Bioelectronics Applications. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9080212] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Organic bioelectronics involves the connection of organic semiconductors with living organisms, organs, tissues, cells, membranes, proteins, and even small molecules. In recent years, this field has received great interest due to the development of all kinds of devices architectures, enabling the detection of several relevant biomarkers, the stimulation and sensing of cells and tissues, and the recording of electrophysiological signals, among others. In this review, we discuss recent functionalization approaches for PEDOT and PEDOT:PSS films with the aim of integrating biomolecules for the fabrication of bioelectronics platforms. As the choice of the strategy is determined by the conducting polymer synthesis method, initially PEDOT and PEDOT:PSS films preparation methods are presented. Later, a wide variety of PEDOT functionalization approaches are discussed, together with bioconjugation techniques to develop efficient organic-biological interfaces. Finally, and by making use of these approaches, the fabrication of different platforms towards organic bioelectronics devices is reviewed.
Collapse
|
13
|
Puttananjegowda K, Takshi A, Thomas S. Silicon Carbide Nanoparticles based Nanofibrous Membrane in Comparison with Thin-Film Enzymatic Glucose Sensor. IEEE Trans Nanobioscience 2021; 20:577-580. [PMID: 34310315 DOI: 10.1109/tnb.2021.3100466] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This work presents, silicon carbide nanoparticles (SiCNPs) embedded in a conductive polymer (CP) to be electrospun to fabricate a nanofibrous membrane and a thin-film. Electrochemical enzymatic glucose sensing mechanism of an electrospun nanofibrous membrane (ENFM) of SiCNPs in a CP compared to a spin-coated-thin-film (SCTF) of SiCNPs in a CP. Fiber alignment in the form of a matrix is a key factor that determines the physical properties of nanofiber membrane compared to thin-film. It is found that glucose sensing electrodes formed by a SiCNPs-ENFM has enhanced binding of the glucose oxidase (GOx) enzyme within the fibrous membrane as compared to a SiCNPs-SCTF. The SiCNPs-ENFM and SiCNPs-SCTF glucose sensing electrodes were characterized for morphology by using scanning electron microscopy (SEM) and for electrochemical activity by using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA) methods. SiCNPs-ENFM based glucose electrodes shown a detection range from a 0.5 mM to 20 mM concentration with a better sensitivity of 387.57 μA/gmMcm2, and low limit of detection (LOD) 552.89 nM compared to SiCNPs-SCTF with sensitivity of 6.477 μA/gmMcm2 and LOD of 60.87 μM. The change in current level with SiCNPs-ENFM was ~14% contrast to ~75% with the SiCNPs-SCTF based glucose sensor over 50 days. The electrochemical analysis results demonstrated that the SiCNPs-ENFM electrode provides enhanced sensitivity, better limit of detection (LOD), and durability compared to SiCNPs-SCTF based glucose sensing electrode.
Collapse
|
14
|
Ajmal Mokhtar SM, Alvarez de Eulate E, Sethumadhavan V, Yamada M, Prow TW, Evans DR. Electrochemical stability of
PEDOT
for wearable
on‐skin
application. J Appl Polym Sci 2021. [DOI: 10.1002/app.51314] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Siti Musliha Ajmal Mokhtar
- Future Industries Institute University of South Australia Mawson Lakes Australia
- Faculty of Electrical Engineering Universiti Teknologi Mara, Johor Branch, Pasir Gudang Campus Masai Malaysia
| | | | | | - Miko Yamada
- Future Industries Institute University of South Australia Mawson Lakes Australia
| | - Tarl W. Prow
- Future Industries Institute University of South Australia Mawson Lakes Australia
| | - Drew R. Evans
- Future Industries Institute University of South Australia Mawson Lakes Australia
| |
Collapse
|
15
|
Puttananjegowda K, Takshi A, Thomas S. Silicon carbide nanoparticles electrospun nanofibrous enzymatic glucose sensor. Biosens Bioelectron 2021; 186:113285. [PMID: 34004507 DOI: 10.1016/j.bios.2021.113285] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 04/17/2021] [Accepted: 04/18/2021] [Indexed: 01/06/2023]
Abstract
This paper presents an electrospun-nanofibrous-membrane (ENFM) of silicon carbide nanoparticles (SiCNPs) with a conductive polymer (CP) for an electrochemical enzymatic glucose sensor. The surface area of a fiber matrix is a key physical property of a nanofiber membrane for enzyme binding. It is found that glucose sensing electrodes, having a SiCNPs-ENFM nanostructure, show enhanced binding of glucose oxidase (GOx) enzyme within the fibrous membrane. Morphological characterization of SiCNPs based ENFM was performed by using scanning electron microscopy (SEM) and using transmission electron microscopy (TEM) for SiC nanoparticles. The electrochemical analysis of SiCNPs-ENFM electrode was conducted by using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA) methods. Glucose concentration was detected at +0.6 V in a 5 mM potassium ferricyanide electrolyte. SiCNPs-ENFM based glucose electrodes show a detection range from 0.5 mM to 20 mM concentration with the sensitivity of 30.75 μA/mM cm2 and the detection limit was 0.56 μM. The lower change in current response for SiCNPs-ENFM based glucose sensing electrodes was observed for a 50 day period.
Collapse
Affiliation(s)
| | - Arash Takshi
- Department of Electrical Engineering, University of South Florida, Tampa, Florida, USA.
| | - Sylvia Thomas
- Department of Electrical Engineering, University of South Florida, Tampa, Florida, USA.
| |
Collapse
|
16
|
Maity S, Datta S, Mishra M, Banerjee S, Das S, Chatterjee K. Poly(3,4 ethylenedioxythiophene)‐tosylate—Its synthesis, properties and various applications. POLYM ADVAN TECHNOL 2020. [DOI: 10.1002/pat.5193] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Shilpa Maity
- Department of Physics Jadavpur University Kolkata India
| | - Salini Datta
- Department of Physics Techno India University Kolkata India
| | - Megha Mishra
- Department of Physics Techno India University Kolkata India
| | | | - Sukhen Das
- Department of Physics Jadavpur University Kolkata India
| | | |
Collapse
|
17
|
Gunapu DVSK, Mudigunda VS, Das A, Rengan AK, Vanjari SRK. Facile synthesis and characterization of Poly (3, 4-ethylenedioxythiophene)/Molybdenum disulfide (PEDOT/MoS2) composite coatings for potential neural electrode applications. J APPL ELECTROCHEM 2020. [DOI: 10.1007/s10800-020-01447-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
18
|
Izzati Ramli N, Alya Batrisya Ismail N, Abd-Wahab F, Wardatul Amani Wan Salim W. Cyclic Voltammetry and Electrical Impedance Spectroscopy of Electrodes Modified with PEDOT:PSS-Reduced Graphene Oxide Composite. TRANSPARENT CONDUCTING FILMS 2019. [DOI: 10.5772/intechopen.80715] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
19
|
Batrisya Ismail NA, Abd-Wahab F, Amani Wan Salim WW. Cyclic Voltammetry and Electrochemical Impedance Spectroscopy of Partially Reduced Graphene Oxide - PEDOT:PSS Transducer for Biochemical Sensing. 2018 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES) 2018. [DOI: 10.1109/iecbes.2018.8626618] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|