1
|
Ji J, Yang H, Li Y, Wang Q, Dong Y, Hu F, Wu G, Bai Z, Chai F, Liu L, Jin B. Response of the partial denitrification coupled with anaerobic ammonia oxidation system to disinfectant residues stress. JOURNAL OF HAZARDOUS MATERIALS 2025; 489:137723. [PMID: 40010223 DOI: 10.1016/j.jhazmat.2025.137723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2025] [Revised: 02/17/2025] [Accepted: 02/22/2025] [Indexed: 02/28/2025]
Abstract
The extensive use of disinfectants, especially NaClO, has resulted in chlorine disinfectant residues entering and impairing the biological treatment system. This study combined with long-term stress and transient shock of chlorine residues to comprehensively evaluate the variations of nitrogen removal performance, microbial community and antibiotic resistance genes composition in the PD/A system. The results showed that low concentration NaClO had no obvious harm to the system, but high concentration (>1 mg/L) NaClO would destroy the nitrogen removal performance of PD/A system. Interestingly, microorganisms in biofilm were more resistant to chlorine residues than that in sludge. Anaerobic ammonia oxidizing bacteria suffered more harm than denitrifying microorganisms, and chlorine residues mainly inhibited the process of converting N2H4 to N2 in anammox reaction. In addition, this study found that sludge showed a more significant increase in ARGs abundance and risk than biofilm. Moreover, risk assessments indicated that chlorine residues increased the risk of ARGs in PD/A systems.
Collapse
Affiliation(s)
- Jiantao Ji
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
| | - Haosen Yang
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
| | - Ying Li
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
| | - Qiyue Wang
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
| | - Yongen Dong
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
| | - Feiyue Hu
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
| | - Guanqi Wu
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
| | - Zhixuan Bai
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
| | - Fengguang Chai
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
| | - Lanhua Liu
- School of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China.
| | - Baodan Jin
- School of Material and Chemical Engineering, Zhengzhou University of Light Industry, Zhengzhou 450001, China.
| |
Collapse
|
2
|
Yun TS, Bhatia M, Cornelius SM, Jeon Y, Bishop WM, Kang DW, Seo Y. Release of algal organic matter from cyanobacteria following application of USEPA-registered chemical algaecides. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 370:122822. [PMID: 39413636 DOI: 10.1016/j.jenvman.2024.122822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2024] [Revised: 09/19/2024] [Accepted: 10/02/2024] [Indexed: 10/18/2024]
Abstract
Increased occurrence of harmful algal blooms significantly impedes uses of freshwater resources, especially as potable water supply. Rapid mitigation using algaecides is common; however, the potential release of algal organic matter (AOM) and cyanotoxins poses challenges due to the difficulty of removal with conventional water treatment and negative health impacts. This study evaluated four USEPA-registered algaecides for their efficacy against Microcystis aeruginosa growth and AOM and cyanotoxin release. Successful inhibition of cell growth was achieved in both unialgal and mixed culture samples at concentrations of 0.2 mg Cu/L for copper-based algaecides and 6 mg H2O2/L for peroxide-based algaecides. At 12 h after treatment (HAT), a significant increase in dissolved phycocyanin was observed, which was more pronounced with copper-based algaecides. Microbial byproduct-related and simple aromatic proteins were measured in the unialgal culture, while microbial byproduct-related proteins and humic-like substances were dominant in the mixed culture samples. In both unialgal and mixed-culture experiments, 0.2 mg Cu/L application of copper-based algaecides was the minimum dosage for cyanobacterial cell inhibition and the lowest release of AOM and cyanotoxins, with Oximycin P5 at 6 mg H2O2/L yielding similar results among peroxide-based algaecides. These results help inform water supply managers on algaecide use toward maintaining integrity of drinking water quality.
Collapse
Affiliation(s)
- Tae-Suh Yun
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH, 43606, United States of America
| | - Mudit Bhatia
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH, 43606, United States of America
| | - Sara M Cornelius
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH, 43606, United States of America
| | - Youchul Jeon
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH, 43606, United States of America
| | - West M Bishop
- SePRO Research and Technology Campus, 16013 Watson Seed Farm Rd., Whitakers, NC, 27891, United States of America
| | - Dae-Wook Kang
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH, 43606, United States of America
| | - Youngwoo Seo
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH, 43606, United States of America; Department of Chemical Engineering, University of Toledo, Mail Stop 307, 3048 Nitschke Hall, Toledo, OH, 43606, United States of America.
| |
Collapse
|
3
|
Jeon Y, Li L, Bhatia M, Ryu H, Santo Domingo JW, Brown J, Goetz J, Seo Y. Impact of harmful algal bloom severity on bacterial communities in a full-scale biological filtration system for drinking water treatment. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 927:171301. [PMID: 38423320 PMCID: PMC11333992 DOI: 10.1016/j.scitotenv.2024.171301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 12/15/2023] [Accepted: 02/25/2024] [Indexed: 03/02/2024]
Abstract
The occurrence of harmful algal blooms (HABs) in freshwater environments has been expanded worldwide with growing frequency and severity. HABs can pose a threat to public water supplies, raising concerns about safety of treated water. Many studies have provided valuable information about the impacts of HABs and management strategies on the early-stage treatment processes (e.g., pre-oxidation and coagulation/flocculation) in conventional drinking water treatment plants (DWTPs). However, the potential effect of HAB-impacted water in the granular media filtration has not been well studied. Biologically-active filters (BAFs), which are used in drinking water treatment and rely largely on bacterial community interactions, have not been examined during HABs in full-scale DWTPs. In this study, we assessed the bacterial community structure of BAFs, functional profiles, assembly processes, and bio-interactions in the community during both severe and mild HABs. Our findings indicate that bacterial diversity in BAFs significantly decreases during severe HABs due to the predominance of bloom-associated bacteria (e.g., Spingopyxis, Porphyrobacter, and Sphingomonas). The excitation-emission matrix combined with parallel factor analysis (EEM-PARAFAC) confirmed that filter influent affected by the severe HAB contained a higher portion of protein-like substances than filter influent samples during a mild bloom. In addition, BAF community functions showed increases in metabolisms associated with intracellular algal organic matter (AOM), such as lipids and amino acids, during severe HABs. Further ecological process and network analyses revealed that severe HAB, accompanied by the abundance of bloom-associated taxa and increased nutrient availability, led to not only strong stochastic processes in the assembly process, but also a bacterial community with lower complexity in BAFs. Overall, this study provides deeper insights into BAF bacterial community structure, function, and assembly in response to HABs.
Collapse
Affiliation(s)
- Youchul Jeon
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH 43606, United States of America
| | - Lei Li
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH 43606, United States of America
| | - Mudit Bhatia
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH 43606, United States of America
| | - Hodon Ryu
- Water Infrastructure Division, Center for Environmental Solutions and Emergency Response, U.S. Environmental Protection Agency, Cincinnati, OH 45268, United States of America
| | - Jorge W Santo Domingo
- Water Infrastructure Division, Center for Environmental Solutions and Emergency Response, U.S. Environmental Protection Agency, Cincinnati, OH 45268, United States of America
| | - Jess Brown
- Carollo Engineers' Research and Development Practice, Costa Mesa, CA 92626, United States of America
| | - Jake Goetz
- City of Toledo Colins Park Water Treatment, Toledo, OH 43605, United States of America
| | - Youngwoo Seo
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH 43606, United States of America; Department of Chemical and Engineering, University of Toledo, Mail Stop 307, 3048 Nitschke Hall, Toledo, OH 43606, United States of America.
| |
Collapse
|
4
|
Oliveira IM, Gomes IB, Simões LC, Simões M. A review of research advances on disinfection strategies for biofilm control in drinking water distribution systems. WATER RESEARCH 2024; 253:121273. [PMID: 38359597 DOI: 10.1016/j.watres.2024.121273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 01/31/2024] [Accepted: 02/05/2024] [Indexed: 02/17/2024]
Abstract
The presence of biofilms in drinking water distribution systems (DWDS) is responsible for water quality deterioration and a possible source of public health risks. Different factors impact the biological stability of drinking water (DW) in the distribution networks, such as the presence and concentration of nutrients, water temperature, pipe material composition, hydrodynamic conditions, and levels of disinfectant residual. This review aimed to evaluate the current state of knowledge on strategies for DW biofilm disinfection through a qualitative and quantitative analysis of the literature published over the last decade. A systematic review method was performed on the 562 journal articles identified through database searching on Web of Science and Scopus, with 85 studies selected for detailed analysis. A variety of disinfectants were identified for DW biofilm control such as chlorine, chloramine, UV irradiation, hydrogen peroxide, chlorine dioxide, ozone, and others at a lower frequency, namely, electrolyzed water, bacteriophages, silver ions, and nanoparticles. The disinfectants can impact the microbial communities within biofilms, reduce the number of culturable cells and biofilm biomass, as well as interfere with the biofilm matrix components. The maintenance of an effective residual concentration in the water guarantees long-term prevention of biofilm formation and improves the inactivation of detached biofilm-associated opportunistic pathogens. Additionally, strategies based on multi-barrier processes by optimization of primary and secondary disinfection combined with other water treatment methods improve the control of opportunistic pathogens, reduce the chlorine-tolerance of biofilm-embedded cells, as well as decrease the corrosion rate in metal-based pipelines. Most of the studies used benchtop laboratory devices for biofilm research. Even though these devices mimic the conditions found in real DWDS, future investigations on strategies for DW biofilm control should include the validity of the promising strategies against biofilms formed in real DW networks.
Collapse
Affiliation(s)
- Isabel Maria Oliveira
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal
| | - Inês Bezerra Gomes
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal
| | - Lúcia Chaves Simões
- CEB - Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057 Braga, Portugal; LABBELS - Associate Laboratory in Biotechnology, Bioengineering and Microelectromechanical Systems, Braga/Guimarães, Portugal
| | - Manuel Simões
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal.
| |
Collapse
|
5
|
Zheng S, Lin T, Chen H, Zhang X, Jiang F. Impact of changes in biofilm composition response following chlorine and chloramine disinfection on nitrogenous disinfection byproduct formation and toxicity risk in drinking water distribution systems. WATER RESEARCH 2024; 253:121331. [PMID: 38377929 DOI: 10.1016/j.watres.2024.121331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 01/17/2024] [Accepted: 02/16/2024] [Indexed: 02/22/2024]
Abstract
In practical drinking water treatment, chlorine and chloramine disinfection exhibit different mechanisms that affect biofilm growth. This study focused on the influence of biofilm composition changes, especially extracellular polymeric substance (EPS) fractions, on the potential formation and toxicity of nitrogenous disinfection by-products (N-DBP). Significant differences in microbial diversity and community structure were observed between the chlorine and chloramine treatments. Notably, the biofilms from the chloramine-treated group had higher microbial dominance and greater accumulation of organic precursors, as evidenced by the semi-quantitative confocal laser-scanning microscopy assay of more concentrated microbial aggregates and polysaccharide proteins in the samples. Additionally, the chloramine-treated group compared with chlorine had a higher EPS matrix content, with a 13.5 % increase in protein. Furthermore, the protein distribution within the biofilm differed; in the chlorine group, proteins were concentrated in the central region, whereas in the chloramine group, proteins were primarily located at the water-biofilm interface. Notably, functional prediction analyses of protein fractions in biofilms revealed specific functional regulation patterns and increased metabolism-related abundance of proteins in the chlorine-treated group. This increase was particularly pronounced for proteins such as dehydrogenases, reductases, transcription factors, and acyl-CoA dehydrogenases. By combining the Fukui function and density functional calculations to further analyse the effect of biofilm component changes on N-DBP production under chlorine/chloramine and by assessing the toxicity risk potential of N-DBP, it was determined that chloramine disinfection is detrimental to biofilm control and the accumulation of protein precursors has a higher formation potential of N-DBPs and toxicity risk, increasing the health risk of drinking water.
Collapse
Affiliation(s)
- Songyuan Zheng
- Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing 210098, China; College of Environment, Hohai University, Nanjing 210098, China
| | - Tao Lin
- Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing 210098, China; College of Environment, Hohai University, Nanjing 210098, China.
| | - Han Chen
- Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing 210098, China; College of Environment, Hohai University, Nanjing 210098, China
| | - Xue Zhang
- Suzhou Water Supply Company, Suzhou 215002, China
| | - Fuchun Jiang
- Suzhou Water Supply Company, Suzhou 215002, China
| |
Collapse
|
6
|
Unrine JM, McCoy N, Christian WJ, Gautam Y, Ormsbee L, Sanderson W, Draper R, Mooney M, Cromer M, Pennell K, Hoover AG. Spatial and seasonal variation in disinfection byproducts concentrations in a rural public drinking water system: A case study of Martin County, Kentucky, USA. PLOS WATER 2024; 3:e0000227. [PMID: 39175793 PMCID: PMC11340270 DOI: 10.1371/journal.pwat.0000227] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 08/24/2024]
Abstract
To increase our understanding of the factors that influence formation of disinfection byproducts (DBPs) in rural drinking systems, we investigated the spatial and seasonal variation in trihalomethane (THM) and haloacetic acid (HAA) concentrations in relation to various chemical and physical variables in a rural public drinking water system in Martin County, Kentucky, USA. We collected drinking water samples from 97 individual homes over the course of one year and analyzed them for temperature, electrical conductivity, pH, free chlorine, total chlorine, THMs (chloroform, bromodichloromethane, dibromochloromethane, dichlorobromomethane, and bromoform) and HAAs (monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, bromoacetic acid, and dibromoacetic acid). Spatial autocorrelation analysis showed only weak overall clustering for HAA concentrations and none for THMs. The relationship between modeled water age and TTHM or HAA5 concentrations varied seasonally. In contrast, there was strong variation for both HAA and THMs, with concentrations of HAA peaking in mid-summer and THMs peaking in early fall. Multiple regression analysis revealed that THM concentrations were strongly correlated with conductivity, while HAA concentrations were more strongly correlated with water temperature. Individual DBP species that only contained chlorine halogen groups were strongly correlated with temperature, while compounds containing bromine were more strongly correlated with conductivity. Further investigation revealed that increased drinking water conductivity associated with low discharge of the Tug Fork River, the source water, is highly correlated with increased concentrations of bromide. Discharge and conductivity of the Tug Fork River changed dramatically through the year contributing to a seasonal peak in bromide concentrations in the late summer and early fall and appeared to be a driver of brominated THM concentrations. Brominated DBPs tend to have higher toxicity than DBPs containing only chlorine, therefore this study provides important insight into the seasonal factors driving risk from exposure to DBPs in rural drinking water systems impacted by bromide.
Collapse
Affiliation(s)
- Jason M. Unrine
- Department of Plant and Soil Sciences, University of Kentucky, Lexington, Kentucky, United States of America
- Kentucky Water Research Institute, University of Kentucky, Lexington, Kentucky, United States of America
| | - Nina McCoy
- Martin County Concerned Citizens, Inc., Inez, Kentucky, United States of America
| | - W. Jay Christian
- Department of Epidemiology and Environmental Health, University of Kentucky, Lexington, Kentucky, United States of America
| | - Yogesh Gautam
- Department of Civil Engineering, University of Kentucky, Lexington, Kentucky, United States of America
| | - Lindell Ormsbee
- Department of Civil Engineering, University of Kentucky, Lexington, Kentucky, United States of America
| | - Wayne Sanderson
- Department of Biosystems and Agricultural Engineering, University of Kentucky, Lexington, Kentucky, United States of America
| | - Ricki Draper
- Livelihoods Knowledge Exchange Network, Lexington, Kentucky, United States of America
- Appalachian Citizens’ Law Center, Inc., Whitesburg, Kentucky, United States of America
| | - Madison Mooney
- Martin County Concerned Citizens, Inc., Inez, Kentucky, United States of America
- Livelihoods Knowledge Exchange Network, Lexington, Kentucky, United States of America
| | - Mary Cromer
- Appalachian Citizens’ Law Center, Inc., Whitesburg, Kentucky, United States of America
| | - Kelly Pennell
- Department of Civil Engineering, University of Kentucky, Lexington, Kentucky, United States of America
| | - Anna G. Hoover
- Department of Epidemiology and Environmental Health, University of Kentucky, Lexington, Kentucky, United States of America
| |
Collapse
|
7
|
Zhang T, Li K, Liu X. DBP-FP change of biofilm in drinking water distribution system induced by sequential UV and chlorine disinfection: Effect of UV dose and influencing mechanism. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 338:122716. [PMID: 37832779 DOI: 10.1016/j.envpol.2023.122716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 09/27/2023] [Accepted: 10/07/2023] [Indexed: 10/15/2023]
Abstract
The issue of biofilm-related disinfection byproducts (DBPs) in drinking water distribution system (DWDS) has garnered significant attention. This study sought to examine the changes in biofilm-originated halogenated DBP formation potential (biofilm DBP-FP) in simulated continuous-flow DWDSs subjected to sequential UV and chlorine disinfection (UV-Cl2) treatments with varying UV doses and to propose the underlying mechanism. The formation potential of trihalomethanes (THMs), haloacetic acids (HAAs), and the total organic halogen (TOX, X = Cl and Br) produced by biofilm were measured. Results showed that the biofilm TOCl-FP was at a minimum with a UV dose of 80 mJ/cm2, corresponding to the lowest amounts of protein and polysaccharides in the extracellular polymeric substances (EPS). Sphingobium, Methylobacterium, and Sphingomonas played a crucial role in protein and polysaccharide biosynthesis. Bacterial community composition characterization together with metabolic function analysis indicated that dominant bacteria varied and metabolic function shifted due to UV-Cl2 disinfection, with Alphaproteobacteria increasing in relative abundance and Bacteroidia showing the opposite trend with increasing UV doses. Correlation analysis suggested that the UV-Cl2 disinfection process led to changes in the water matrix, including organics, inorganics, bacteria, and components that provide environmental pressure for the biofilm. These changes ultimately influenced the properties of the biofilm EPS, which had a direct impact on biofilm DBP-FP.
Collapse
Affiliation(s)
- Tuqiao Zhang
- Zhejiang Key Laboratory of Drinking Water Safety and Distribution Technology, Zhejiang University, Hangzhou, 310058, PR China
| | - Kexin Li
- Zhejiang Key Laboratory of Drinking Water Safety and Distribution Technology, Zhejiang University, Hangzhou, 310058, PR China
| | - Xiaowei Liu
- Zhejiang Key Laboratory of Drinking Water Safety and Distribution Technology, Zhejiang University, Hangzhou, 310058, PR China; Ocean College, Zhejiang University, Hangzhou, 310058, PR China.
| |
Collapse
|
8
|
Zheng S, Lin T, Zhang X, Jiang F. Response mechanisms of pipe wall biofilms in water supply networks under different disinfection strategy pressures and the effect of mediating halogenated acetonitrile formation. CHEMOSPHERE 2023; 344:140382. [PMID: 37806328 DOI: 10.1016/j.chemosphere.2023.140382] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 08/23/2023] [Accepted: 10/05/2023] [Indexed: 10/10/2023]
Abstract
Residual chlorine and biofilm coexistence is inevitable in drinking water transmission and distribution networks. Understanding the microbial response and its mediated effects on disinfection byproducts under different categories of residual chlorine stress is essential to ensure water safety. The aim of our study was to determine the response of pipe wall biofilms to residual chlorine pressure in chlorine and chloramine systems and to understand the microbially mediated effects on the formation and migration of haloacetonitriles (HANs), typical nitrogenous disinfection byproducts. According to the experimental results, the biofilm response changes under pressure, with significant differences noted in morphological characteristics, the extracellular polymeric substances (EPS) spatial structure, bacterial diversity, and functional abundance potential. Upon incubation with residual chlorine (1.0 ± 0.2 mg/L), the biofilm biomass per unit area, EPS, community abundance, and diversity increased in the chloramine group, and the percentage of viable bacteria increased, potentially indicating that the chloramine group provides a richer variety of organic matter precursors. Compared with the chloramine group, the chlorination group exhibited increased haloacetonitrile formation potential (HANFP), with Rhodococcus (43.2%) dominating the system, whereas the prediction abundance of metabolic functions was advantageous, especially with regard to amino acid metabolism, carbohydrate metabolism, and the biodegradation and metabolism of foreign chemicals. Under chlorine stress, pipe wall biofilms play a stronger role in mediating HAN production. It is inferred that chlorine may stimulates microbial interactions, and more metabolites (e.g., EPS) consume chlorine to protect microbial survival. EPS dominates in biofilms, in which proteins exhibit greater HANFP than polysaccharides.
Collapse
Affiliation(s)
- Songyuan Zheng
- Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, PR China; College of Environment, Hohai University, Nanjing, 210098, PR China
| | - Tao Lin
- Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing, 210098, PR China; College of Environment, Hohai University, Nanjing, 210098, PR China.
| | - Xue Zhang
- Suzhou Water Supply Company, Suzhou, 215002, China
| | - Fuchun Jiang
- Suzhou Water Supply Company, Suzhou, 215002, China
| |
Collapse
|
9
|
Cen C, Zhang K, Zhang T, Wu J, Mao X. Exploring the ignored role of escaped algae in a pilot-scale DWDS: Disinfectant consumption, DBP yield and risk formation. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 337:122599. [PMID: 37739259 DOI: 10.1016/j.envpol.2023.122599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Revised: 09/04/2023] [Accepted: 09/20/2023] [Indexed: 09/24/2023]
Abstract
Insufficient treatments during bloom-forming seasons allow algae to enter the subsequent drinking water distribution system (DWDS). Yet, scarce information is available regarding the role escaped algae to play in the DWDS, and how they interact with the system. Thus, three scenarios were conducted: a pilot DWDS with algae (a), pipe water (b), and pipe water with algae (c). Experimental results showed that, compared to biofilm and bulk water, escaped algae required fewer disinfectants. Competition for disinfectants varied with algal strains (Microcystis aeruginosa, MA; Pseudanabaena sp., PS) and disinfectant types (chlorine, Cl2; chloriamine, NH2Cl). Algae in the MA-Cl2 group showed the highest demand (6.25%-36.02%). However, the low-concentration disinfectants distributed to algae could trigger distinct algal status alternations. Cl2 diffused into intact MA cells and reacted with intracellular compositions. Damaged PS cells reached 100% within 2 h. Typical disinfection byproducts (DBPs), including trihalomethanes (THMs), haloacetic acids and halogenated acetonitriles were examined. Disinfectant types and algal strains affected DBP yield and distribution. Although disinfectants consumed by algae might not promote dissolved DBP formation, especially for THMs. DBP formation of the other components was affected by escaped algae via changing disinfectant assignment (reduced by 45.45% for MA-Cl2) and transformation efficiency (by 34.52%). The cytotoxicity risks were estimated. Dissolved DBP-induced risks were not added when escaped algae occurred, whereas disruption and release of intracellular substances increased risks; the maximum cytotoxicity did not occur at 12 h rather than at the end (24 h). Overall, this study provided an innovative perspective on algal-related water quality issues in water systems.
Collapse
Affiliation(s)
- Cheng Cen
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, 310058, China; Zhejiang Key Laboratory of Drinking Water Safety and Distribution Technology, Hangzhou, 310058, China
| | - Kejia Zhang
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, 310058, China; Zhejiang Key Laboratory of Drinking Water Safety and Distribution Technology, Hangzhou, 310058, China; Innovation Center of Yangtze River Delta, Zhejiang University, Jiaxing, 314100, China.
| | - Tuqiao Zhang
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, 310058, China; Zhejiang Key Laboratory of Drinking Water Safety and Distribution Technology, Hangzhou, 310058, China; Innovation Center of Yangtze River Delta, Zhejiang University, Jiaxing, 314100, China
| | - Jiajia Wu
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, 310058, China; Zhejiang Key Laboratory of Drinking Water Safety and Distribution Technology, Hangzhou, 310058, China
| | - Xinwei Mao
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, 310058, China; Zhejiang Key Laboratory of Drinking Water Safety and Distribution Technology, Hangzhou, 310058, China
| |
Collapse
|
10
|
Li S, Niu Z, Zhang Y. The prevalence of extra- and intra- cellular antibiotic resistance genes and the relationship with bacterial community in different layers of biofilm in the simulated drinking water pipelines. JOURNAL OF WATER PROCESS ENGINEERING 2023; 53:103780. [DOI: 10.1016/j.jwpe.2023.103780] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
11
|
Sójka O, van der Mei HC, van Rijn P, Gagliano MC. Zwitterionic poly(sulfobetaine methacrylate)-based hydrogel coating for drinking water distribution systems to inhibit adhesion of waterborne bacteria. Front Bioeng Biotechnol 2023; 11:1066126. [PMID: 36896012 PMCID: PMC9989184 DOI: 10.3389/fbioe.2023.1066126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 02/08/2023] [Indexed: 02/25/2023] Open
Abstract
Presence of biofilms in drinking water distribution systems (DWDS) can be a nuisance, leading to several operational and maintenance issues (i.e., increased secondary disinfectants demand, pipe damage or increased flow resistance), and so far, no single control practice was found to be sufficiently effective. Here, we propose poly (sulfobetaine methacrylate) (P(SBMA))-based hydrogel coating application as a biofilm control strategy in DWDS. The P(SBMA) coating was synthetized through photoinitiated free radical polymerization on polydimethylsiloxane with different combinations of SBMA as a monomer, and N, N'-methylenebis (acrylamide) (BIS) as a cross-linker. The most stable coating in terms of its mechanical properties was obtained using 20% SBMA with a 20:1 SBMA:BIS ratio. The coating was characterized using Scanning Electron Microscopy, Energy Dispersive X-Ray Spectroscopy, and water contact angle measurements. The anti-adhesive performance of the coating was evaluated in a parallel-plate flow chamber system against adhesion of four bacterial strains representing genera commonly identified in DWDS biofilm communities, Sphingomonas and Pseudomonas. The selected strains exhibited varying adhesion behaviors in terms of attachment density and bacteria distribution on the surface. Despite these differences, after 4 h, presence of the P(SBMA)-based hydrogel coating significantly reduced the number of adhering bacteria by 97%, 94%, 98% and 99%, for Sphingomonas Sph5, Sphingomonas Sph10, Pseudomonas extremorientalis and Pseudomonas aeruginosa, respectively, compared to non-coated surfaces. These findings motivate further research into a potential application of a hydrogel anti-adhesive coating as a localized biofilm control strategy in DWDS, especially on materials known to promote excessive biofilm growth.
Collapse
Affiliation(s)
- Olga Sójka
- Wetsus, European Centre of Excellence for Sustainable Water Technology, Leeuwarden, Netherlands.,Department of Biomedical Engineering, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Henny C van der Mei
- Department of Biomedical Engineering, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Patrick van Rijn
- Department of Biomedical Engineering, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Maria Cristina Gagliano
- Wetsus, European Centre of Excellence for Sustainable Water Technology, Leeuwarden, Netherlands
| |
Collapse
|
12
|
Baranwal P, Kang DW, Seo Y. Impacts of algal organic matter and humic substances on microcystin-LR removal and their biotransformation during the biodegradation process. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 852:157993. [PMID: 35964751 DOI: 10.1016/j.scitotenv.2022.157993] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 08/08/2022] [Accepted: 08/08/2022] [Indexed: 06/15/2023]
Abstract
The application of bioaugmentation (i.e., injection of contaminant-degrading microorganisms) has shown its potential to remove harmful cyanotoxins like microcystin-LR (MC-LR) from drinking water sources. However, the natural organic matter (NOM) present in both natural and engineered water systems might affect the bacterial biodegradation of MC-LR. Therefore, for the successful application of bioaugmentation for MC-LR removal in water treatment, it is important to understand NOM effects on MC-LR biodegradation. In this study, the impact of NOM [algal organic matter (AOM) and humic substances (HS)] on MC-LR biodegradation was evaluated in the presence of varying concentrations of NOM by monitoring MC-LR biodegradation kinetics. The changes in NOM composition during MC-LR biodegradation were also characterized by a five-component Parallel factor (PARAFAC) model using 336 excitation-emission matrix (EEM) spectra collected at different sampling points. Our results showed decreases in MC-LR biodegradation rate of 1.6-and 3.4-fold in the presence of AOM and HS, respectively. The expression of the functional mlrA gene exhibited a similar trend to the MC-LR degradation rate at different NOM concentrations. EEM-PARAFAC analyses and NOM molecular size fractionation results indicated a relatively greater production of terrestrial humic-like components (57%) and a decrease of protein-like components. Two-dimensional correlation spectroscopy (2D-COS) analyses further confirmed that low molecular weight protein-like components were initially utilized by bacteria, followed by the formation of higher molecular weight humic-like components, likely due to microbial metabolism.
Collapse
Affiliation(s)
- Parul Baranwal
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH 43606, United States
| | - Dae-Wook Kang
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH 43606, United States
| | - Youngwoo Seo
- Department of Civil and Environmental Engineering, University of Toledo, Mail Stop 307, 3006 Nitschke Hall, Toledo, OH 43606, United States; Department of Chemical Engineering, University of Toledo, Mail Stop 307, 3048 Nitschke Hall, Toledo, OH 43606, United States.
| |
Collapse
|
13
|
Shi X, Clark GG, Huang C, Nguyen TH, Yuan B. Chlorine decay and disinfection by-products formation during chlorination of biofilms formed with simulated drinking water containing corrosion inhibitors. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 815:152763. [PMID: 34990663 DOI: 10.1016/j.scitotenv.2021.152763] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/21/2021] [Accepted: 12/25/2021] [Indexed: 06/14/2023]
Abstract
Corrosion inhibitors used to reduce pipe corrosion can alter the physical structure and biochemical components of the biofilm in premise plumbing systems. We studied the effects of corrosion inhibitors on chlorine decay and associated disinfection by-products (DBPs) formation by biofilms grown with simulated drinking water amended with silicate, phosphate, and the phosphate blends. Experiments were conducted with either intact biofilms or biofilm materials dispersed in solution during sonication (referred to as biomass). While there was no significant difference in chlorine decay among biomass from different biofilms, biomass from the phosphate blend biofilm showed the lowest trihalomethane (THMs) and haloacetic acids (HAAs) formation. The chlorine decay rate constants from the biofilm experiment were ranked as: phosphate blends > phosphate ≈ groundwater (GW) > silicate. The kinetics of chlorine decay and formation of DBPs were successfully described by pseudo-first-order kinetics. These fitting parameters were used to predict the DBPs formation in a realistic premise plumbing system. The results showed that biofilm-derived THMs and HAAs increased with increasing chlorine concentration, while THMs and HAAs first increased and then stabilized to a maximum with increasing biofilm total organic carbon (TOC) concentration. In general, the biofilms grown with phosphate-based corrosion inhibitors resulted in lower DBPs formation yield but higher bacterial release, which could potentially increase the risk of user exposure to opportunistic pathogens in drinking water. The silicate biofilms showed the largest yield coefficient of DBPs formation but had the least biomass and lower bacterial release.
Collapse
Affiliation(s)
- Xiaoyang Shi
- Xiamen Key Laboratory of Municipal and Industrial Solid Waste Utilization and Pollution Control, College of Civil Engineering, Huaqiao University, Xiamen, Fujian 361021, PR China
| | - Gemma G Clark
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, United States
| | - Conghui Huang
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, United States
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, United States
| | - Baoling Yuan
- Xiamen Key Laboratory of Municipal and Industrial Solid Waste Utilization and Pollution Control, College of Civil Engineering, Huaqiao University, Xiamen, Fujian 361021, PR China.
| |
Collapse
|
14
|
Qi P, Li T, Hu C, Li Z, Bi Z, Chen Y, Zhou H, Su Z, Li X, Xing X, Chen C. Effects of cast iron pipe corrosion on nitrogenous disinfection by-products formation in drinking water distribution systems via interaction among iron particles, biofilms, and chlorine. CHEMOSPHERE 2022; 292:133364. [PMID: 34933025 DOI: 10.1016/j.chemosphere.2021.133364] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Revised: 11/28/2021] [Accepted: 12/16/2021] [Indexed: 06/14/2023]
Abstract
The effects of cast iron pipe corrosion on nitrogenous disinfection by-products formation (N-DBPs) in drinking water distribution systems (DWDSs) were investigated. The results verified that in the effluent of corroded DWDSs simulated by annular reactors with corroded cast iron coupons, typical N-DBPs, including haloacetamides, halonitromethanes, and haloacetonitriles, increased significantly compared with the influent of DWDSs. In addition, more dissolved organic carbon, adenosine triphosphate, and iron particles were simultaneously detected in the bulk water of corroded DWDSs, thereby indicating that abundant iron particles acted as a "protective umbrella" for microorganisms. Under the condition of corroded DWDSs, the extracellular polymeric substances gradually exhibited distinct characteristics, including a higher content and lower flocculation efficiency, thereby resulting in a large supply of N-DBPs precursors. Corroded cast iron pipes, equivalent to a unique microbial interface, induced completely distinct microbial community structures and metabolic functions in DWDSs, thereby enhancing the formation of N-DBPs. This is the first study to successfully reveal the interactions among iron particles, biofilms, and chlorine in DWDSs, which may help to fully understand the biofilm transformation and microbial community succession in DWDSs.
Collapse
Affiliation(s)
- Peng Qi
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Tong Li
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Chun Hu
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Zesong Li
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Zhihao Bi
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Youyi Chen
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Huishan Zhou
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Ziliang Su
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Xinjun Li
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Xueci Xing
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China.
| | - Chaoxiang Chen
- Nanzhou Waterworks of Guangzhou Water Supply Co. Ltd., Guangzhou, 510000, China
| |
Collapse
|