1
|
Advances in the Analysis of Veterinary Drug Residues in Food Matrices by Capillary Electrophoresis Techniques. Molecules 2019; 24:molecules24244617. [PMID: 31861089 PMCID: PMC6943715 DOI: 10.3390/molecules24244617] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 12/13/2019] [Accepted: 12/14/2019] [Indexed: 12/03/2022] Open
Abstract
In the last years, the European Commission has adopted restrictive directives on food quality and safety in order to protect animal and human health. Veterinary drugs represent an important risk and the need to have sensitive and fast analytical techniques to detect and quantify them has become mandatory. Over the years, the availability of different modes, interfaces, and formats has improved the versatility, sensitivity, and speed of capillary electrophoresis (CE) techniques. Thus, CE represents a powerful tool for the analysis of a large variety of food matrices and food-related molecules with important applications in food quality and safety. This review focuses the attention of CE applications over the last decade on the detection of different classes of drugs (used as additives in animal food or present as contaminants in food products) with a potential risk for animal and human health. In addition, considering that the different sample preparation procedures have strongly contributed to CE sensitivity and versatility, the most advanced sample pre-concentration techniques are discussed here.
Collapse
|
2
|
Liu Y, Zhou W, Mao Z, Chen Z. Analysis of Evodiae Fructus by capillary electrochromatography-mass spectrometry with methyl-vinylimidazole functionalized organic polymer monolilth as stationary phases. J Chromatogr A 2019; 1602:474-480. [PMID: 31202495 DOI: 10.1016/j.chroma.2019.06.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 05/24/2019] [Accepted: 06/04/2019] [Indexed: 12/20/2022]
Abstract
Evodiae Fructus is used as a traditional Chinese medicine for the treatment of several kinds of diseases with its bioactive constituents. In this study, a capillary electrochromatography-mass spectrometry (CEC-MS) method was developed to determine three bioactive compounds including evodiamine, rutaecarpine and limonin in Evodiae Fructus fruit. Home-developed monolithic columns with methyl-vinylimidazole functionalized organic polymer monolilth as stationary phases were used in CEC-MS with excellent separation selectivity and high efficiency. The CEC-MS methods provided 4-16 folds improvement of LODs when compared with CEC-UV method. The conditions, which could affect separation efficiency and detection sensitivity, were optimized. Under optimum conditions, baseline separation with high detection sensitivity was obtained. The method showed good linearity (R2 >0.99) of 0.8-160 μg mL-1 with low limits of detection of 0.15-0.31 μg mL-1. Relative standard deviations of migration time and relative peak areas were <13.89%. Recoveries of evodiamine, rutaecarpine and limonin in Evodiae Fructus fruit were tested and calculated, which ranged from 102% to 113%. Finally, the three bioactive compounds in Evodiae Fructus herb samples from different regions were analyzed and studied. It has been demonstrated that the developed method has great potential for quality control of Evodiae Fructus herb.
Collapse
Affiliation(s)
- Yikun Liu
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, and Wuhan University School of Pharmaceutical Sciences, Wuhan, 430071, China; State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 10080, China
| | - Wei Zhou
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, and Wuhan University School of Pharmaceutical Sciences, Wuhan, 430071, China
| | - Zhenkun Mao
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, and Wuhan University School of Pharmaceutical Sciences, Wuhan, 430071, China
| | - Zilin Chen
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, and Wuhan University School of Pharmaceutical Sciences, Wuhan, 430071, China; State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 10080, China.
| |
Collapse
|
3
|
Aydoğan C, Gökaltun A, Denizli A, El‐Rassi Z. Organic polymer‐based monolithic capillary columns and their applications in food analysisψ. J Sep Sci 2019; 42:962-979. [DOI: 10.1002/jssc.201801051] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2018] [Revised: 12/13/2018] [Accepted: 12/18/2018] [Indexed: 01/09/2023]
Affiliation(s)
- Cemil Aydoğan
- Department of Food EngineeringBingöl University Bingöl Turkey
| | - Aslıhan Gökaltun
- Department of Chemical EngineeringHacettepe University Ankara Turkey
| | - Adil Denizli
- Department of ChemistryHacettepe University Ankara Turkey
| | - Ziad El‐Rassi
- Department of ChemistryOklahoma State University Stillwater OK USA
| |
Collapse
|
4
|
Mao X, Liu L, Xiao F, Ni W, Cheng X. An innovative reversed-phase monolithic column modified with 4-vinylbiphenyl and ionic liquid stationary phases for capillary electrochromatography. NEW J CHEM 2019. [DOI: 10.1039/c9nj02116g] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
A poly(VBP-co-EDMA-co-IL) monolithic column was used for electrochromatographic separation.
Collapse
Affiliation(s)
- Xiangju Mao
- Zhengzhou Institute of Multipurpose Utilization of Mineral Resources
- CAGS
- Zhengzhou 450006
- P. R. China
- China National Engineering Research Center for Utilization of Industrial Minerals
| | - Lu Liu
- Zhengzhou Institute of Multipurpose Utilization of Mineral Resources
- CAGS
- Zhengzhou 450006
- P. R. China
- China National Engineering Research Center for Utilization of Industrial Minerals
| | - Fang Xiao
- Zhengzhou Institute of Multipurpose Utilization of Mineral Resources
- CAGS
- Zhengzhou 450006
- P. R. China
- China National Engineering Research Center for Utilization of Industrial Minerals
| | - Wenshan Ni
- Zhengzhou Institute of Multipurpose Utilization of Mineral Resources
- CAGS
- Zhengzhou 450006
- P. R. China
- China National Engineering Research Center for Utilization of Industrial Minerals
| | - Xintao Cheng
- Zhengzhou Institute of Multipurpose Utilization of Mineral Resources
- CAGS
- Zhengzhou 450006
- P. R. China
- China National Engineering Research Center for Utilization of Industrial Minerals
| |
Collapse
|
5
|
Wang J, Ding C, Xiao J, Jia W, Chen Y, Lin X, Xie Z. Quinine-modified polymer monolithic column with reversed-phase /strong anion-exchange mixed-mode for pressurized capillary electrochromatography. Electrophoresis 2018; 39:1504-1511. [DOI: 10.1002/elps.201800003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2018] [Revised: 02/28/2018] [Accepted: 03/13/2018] [Indexed: 11/05/2022]
Affiliation(s)
- Jiabin Wang
- Institute of Food Safety and Environment Monitoring; Fuzhou University; Fuzhou P. R. China
- Institute of Biomedical and Pharmaceutical Technology; Fuzhou University; Fuzhou P. R. China
| | - Changying Ding
- Institute of Food Safety and Environment Monitoring; Fuzhou University; Fuzhou P. R. China
| | - Jianhua Xiao
- Institute of Biomedical and Pharmaceutical Technology; Fuzhou University; Fuzhou P. R. China
| | - Wenchao Jia
- Institute of Food Safety and Environment Monitoring; Fuzhou University; Fuzhou P. R. China
| | - Yongxuan Chen
- Fujian Inspection and Research Institute for product quality; National Center of Processed Foods Quality Supervision and Inspection; Fuzhou P. R. China
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring; Fuzhou University; Fuzhou P. R. China
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring; Fuzhou University; Fuzhou P. R. China
| |
Collapse
|
6
|
D'Orazio G, Asensio-Ramos M, Fanali C, Hernández-Borges J, Fanali S. Capillary electrochromatography in food analysis. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.06.012] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
7
|
Moravcová D, Rantamäki AH, Duša F, Wiedmer SK. Monoliths in capillary electrochromatography and capillary liquid chromatography in conjunction with mass spectrometry. Electrophoresis 2016; 37:880-912. [PMID: 26800083 DOI: 10.1002/elps.201500520] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2015] [Revised: 12/18/2015] [Accepted: 12/21/2015] [Indexed: 12/29/2022]
Abstract
Here, we have reviewed separation studies utilizing monolithic capillary columns for separation of compounds preceding MS analysis. The review is divided in two parts according to the used separation method, namely CEC and capillary LC (cLC). Based on our overview, monolithic CEC-MS technique have been more focused on the syntheses of highly specialized and selective separation phase materials for fast and efficient separation of specific types of analytes. In contrast, monolithic cLC-MS is more widely used and is often employed, for instance, in the analysis of oligonucleotides, metabolites, and peptides and proteins in proteomic studies. While poly(styrene-divinylbenzene)-based and silica-based monolithic capillaries found their place in proteomic analyses, the other laboratory-synthesized monoliths still wait for their wider utilization in routine analyses. The development of new monolithic materials will most likely continue due to the demand of more efficient and rapid separation of increasingly complex samples.
Collapse
Affiliation(s)
- Dana Moravcová
- Institute of Analytical Chemistry of the CAS, v. v. i, Brno, Czech Republic
| | | | - Filip Duša
- Institute of Analytical Chemistry of the CAS, v. v. i, Brno, Czech Republic
| | | |
Collapse
|
8
|
Hernández-Mesa M, D'Orazio G, Rocco A, García-Campaña AM, Blanco CC, Fanali S. Capillary electrochromatography-mass spectrometry for the determination of 5-nitroimidazole antibiotics in urine samples. Electrophoresis 2015. [PMID: 26200811 DOI: 10.1002/elps.201500126] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The separation of eight antibiotics belonging to 5-nitroimidazole family was carried out by means of CEC coupled with MS. Preliminary experiments were carried out with ultraviolet detection in order to select the proper stationary and mobile phase. Among the different stationary phases studied (namely Lichrospher C18, 5 μm particle size; Cogent(TM) Bidentate C18, 4.2 μm; Pinnacle II™ Phenyl, 3 μm; Pinnacle II™ Cyano, 3 μm), Cogent™ Bidentate C18 (4.2 μm) gave the best performance. For CEC-MS coupling, a laboratory assembled liquid-junction-nano-spray interface was used. In order to achieve a good sensitivity, special attention was paid to both optimization of the sheath liquid composition as well as selection of the injection mode. Under optimized CEC-ESI-MS conditions, the separation was accomplished within 22 min by using a column packed with a mixture of Bidentate C18:Lichrospher Silica-60 (5 μm) 3:1 w/w, an inlet pressure of 11 bar, a voltage of 15 kV, and a mobile phase composed by 45:10:45 v/v/v ACN/MeOH/water containing ammonium acetate (5 mM pH 5). A combined hydrodynamic and electrokinetic injection of 8 bar, 15 kV, and 96 s was adopted. The method was validated in terms of repeatability and intermediate precision of retention times and peak areas, linearity, and LODs and LOQs. RSDs values were <2.9% for retention times and <16.1% for peak areas in both intraday and interday experiments. LOQ values were between 0.09 and 0.42 μg/mL for all compounds. Finally, the method was applied to the determination of three most employed 5-nitroimidazole antibiotics (metronidazole, secnidazole, and ternidazole) in spiked urine samples, subjected to a SPE procedure. Recovery values in the 67-103% range were obtained. Furthermore, for the selected antibiotics, CEC-MS(2) spectra were obtained providing the unambiguous confirmation of these drugs in urine samples.
Collapse
Affiliation(s)
- Maykel Hernández-Mesa
- Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Monterotondo, Italy.,Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Granada, Spain
| | - Giovanni D'Orazio
- Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Monterotondo, Italy
| | - Anna Rocco
- Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Monterotondo, Italy
| | - Ana M García-Campaña
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Granada, Spain
| | - Carmen Cruces Blanco
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Granada, Spain
| | - Salvatore Fanali
- Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Monterotondo, Italy
| |
Collapse
|
9
|
Liu WL, Lirio S, Yang Y, Wu LT, Hsiao SY, Huang HY. A poly(alkyl methacrylate-divinylbenzene-vinylbenzyl trimethylammonium chloride) monolithic column for solid-phase microextraction. J Chromatogr A 2015; 1395:32-40. [DOI: 10.1016/j.chroma.2015.03.066] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2015] [Revised: 03/23/2015] [Accepted: 03/24/2015] [Indexed: 10/23/2022]
|
10
|
Domínguez-Vega E, Pérez-Fernández V, Crego AL, García MÁ, Marina ML. Recent advances in CE analysis of antibiotics and its use as chiral selectors. Electrophoresis 2014; 35:28-49. [PMID: 24395661 DOI: 10.1002/elps.201300347] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Revised: 10/06/2013] [Accepted: 10/06/2013] [Indexed: 12/24/2022]
Abstract
Antibiotics are a class of therapeutic molecules widely employed in both human and veterinary medicine. This article reviews the most recent advances in the analysis of antibiotics by CE in pharmaceutical, environmental, food, and biomedical fields. Emphasis is placed on the strategies to increase sensitivity as diverse off-line, in-line, and on-line preconcentration approaches and the use of different detection systems. The use of CE in the microchip format for the analysis of antibiotics is also reviewed in this article. Moreover, since the use of antibiotics as chiral selectors in CE has grown in the last years, a new section devoted to this aspect has been included. This review constitutes an update of previous published reviews and covers the literature published from June 2011 until June 2013.
Collapse
Affiliation(s)
- Elena Domínguez-Vega
- Department of Biomolecular Analysis, Faculty of Sciences, Utrecht University, Utrecht, The Netherlands
| | | | | | | | | |
Collapse
|
11
|
Analyses of polycyclic aromatic hydrocarbons in seafood by capillary electrochromatography–atmospheric pressure chemical ionization/mass spectrometry. J Chromatogr A 2013; 1313:132-8. [DOI: 10.1016/j.chroma.2013.08.035] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Revised: 07/24/2013] [Accepted: 08/12/2013] [Indexed: 01/26/2023]
|