1
|
Chen S, Zhou D, Xiong Q, Yang Y, Zhang M, Chen S. Electrochemical sensors based on composites of porous Fe 3O 4/C and carbon black for sensitive and rapid detection of propofol. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:8399-8407. [PMID: 39552219 DOI: 10.1039/d4ay01280a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2024]
Abstract
Nowadays, many people are turning to medications that can help them stay calm during surgeries and their daily lives. As an anesthetic that reduces the excitability of nerve cells, propofol can achieve sedation with the advantages of fast onset and short half-life. The development of propofol sensors has tremendous application potential because they can help healthcare professionals dynamically regulate the concentration of propofol in the blood, not only to achieve the painless surgeries that patients want, to maintain the sedation that surgeons desire, but also to prevent the respiratory failure that may occur with a patient's daily sleep aids. In this paper, we prepared Fe3O4/C/CB nanocomposites by doping carbon black on the surface of the pyrolyzed product of MIL-88B. The nanocomposites-modified glassy carbon electrodes were used to detect propofol in phosphate buffer solution. The porous nanocomposites with high electrical conductivity promoted the charge transfer on the electrode surface, improving the performance of the modified electrodes. After optimization, the linear range, the detection limit, and the sensitivity for propofol were 5.0-205 μM, 0.102 μM, and 2.850 μA cm-2 μM-1, respectively. The electrochemical sensing of propofol in a medical propofol emulsion injection and in normal human serum showed that the method was rapid and repeatable.
Collapse
Affiliation(s)
- Shouhui Chen
- Department of Chemistry, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| | - Dan Zhou
- Department of Chemistry, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| | - Qinghao Xiong
- Department of Chemistry, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| | - Yinan Yang
- Department of Chemistry, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| | - Mingyang Zhang
- Department of Chemistry, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| | - Shoulin Chen
- Department of Anesthesiology, The Second Affiliated Hospital of Nanchang University, 1 Minde Road, Nanchang 330006, China
| |
Collapse
|
2
|
Hack T, Bisarra J, Chung S, Kummari S, Hall DA. Mitigating Medication Tampering and Diversion via Real-Time Intravenous Opioid Quantification. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:756-770. [PMID: 38814775 DOI: 10.1109/tbcas.2024.3405815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
Opioid tampering and diversion pose a serious problem for hospital patients with potentially life-threatening consequences. The ongoing opioid crisis has resulted in medications used for pain management and anesthesia, such as fentanyl and morphine, being stolen, substituted with a different substance, and abused. This work aims to mitigate tampering and diversion through analytical verification of the administered drug before it enters the patient. We present an electrochemical-based sensor and miniaturized wireless potentiostat that enable real-time intravenous (IV) monitoring of opioids, specifically fentanyl and morphine. The proposed system is connected to an IV drip system during surgery or post-operation recovery. Measurement results of two opioids are presented, including calibration curves and data on the sensor performance concerning pH, temperature, interference, reproducibility, and long-term stability. Finally, we demonstrate real-time fluidic measurements connected to a flow cell to simulate IV administration and a blind study classified using a machine-learning algorithm. The system achieves limits of detection (LODs) of 1.26 µg/mL and 2.75 µg/mL for fentanyl and morphine, respectively, while operating with >1-month battery lifetime due to an optimized ultra-low power 36 µA sleep mode.
Collapse
|
3
|
Ahmed B, Reiche CF, Magda JJ, Solzbacher F, Körner J. Smart Hydrogel Swelling State Detection Based on a Power-Transfer Transduction Principle. ACS APPLIED POLYMER MATERIALS 2024; 6:5544-5554. [PMID: 38752016 PMCID: PMC11091848 DOI: 10.1021/acsapm.4c00808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 04/08/2024] [Accepted: 04/16/2024] [Indexed: 05/18/2024]
Abstract
Stimulus-responsive (smart) hydrogels are a promising sensing material for biomedical contexts due to their reversible swelling change in response to target analytes. The design of application-specific sensors that utilize this behavior requires the development of suitable transduction concepts. The presented study investigates a power-transfer-based readout approach that is sensitive to small volumetric changes of the smart hydrogel. The concept employs two thin film polyimide substrates with embedded conductive strip lines, which are shielded from each other except at the tip region, where the smart hydrogel is sandwiched in between. The hydrogel's volume change in response to a target analyte alters the distance and orientation of the thin films, affecting the amount of transferred power between the two transducer parts and, consequently, the measured sensor output voltage. With proper calibration, the output signal can be used to determine the swelling change of the hydrogel and, consequently, to quantify the stimulus. In proof-of-principle experiments with glucose- and pH-sensitive smart hydrogels, high sensitivity to small analyte concentration changes was found along with very good reproducibility and stability. The concept was tested with two exemplary hydrogels, but the transduction principle in general is independent of the specific hydrogel material, as long as it exhibits a stimulus-dependent volume change. The application vision of the presented research is to integrate in situ blood analyte monitoring capabilities into standard (micro)catheters. The developed sensor is designed to fit into a catheter without obstructing its normal use and, therefore, offers great potential for providing a universally applicable transducer platform for smart catheter-based sensing.
Collapse
Affiliation(s)
- Benozir Ahmed
- Department
of Electrical & Computer Engineering, University of Utah, Salt Lake
City, Utah 84112, United States
| | - Christopher F. Reiche
- Department
of Electrical & Computer Engineering, University of Utah, Salt Lake
City, Utah 84112, United States
| | - Jules J. Magda
- Department
of Chemical Engineering, University of Utah, Salt Lake City, Utah 84112, United States
| | - Florian Solzbacher
- Department
of Electrical & Computer Engineering, University of Utah, Salt Lake
City, Utah 84112, United States
| | - Julia Körner
- Faculty
of
Electrical Engineering & Computer Science, Leibniz Universität Hannover, 30167 Hannover, Germany
| |
Collapse
|
4
|
Marenco A, Pillai RG, Harris KD, Chan NWC, Jemere AB. Electrochemical Determination of Fentanyl Using Carbon Nanofiber-Modified Electrodes. ACS OMEGA 2024; 9:17592-17601. [PMID: 38645354 PMCID: PMC11024940 DOI: 10.1021/acsomega.4c00816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 03/21/2024] [Accepted: 03/27/2024] [Indexed: 04/23/2024]
Abstract
In this work, we report the direct electrochemical oxidation of fentanyl using commercial screen-printed carbon electrodes (SPCEs) modified with carboxyl-functionalized carbon nanofibers (fCNFs). CNFs have surface chemistry and reactivity similar to carbon nanotubes (CNTs), yet they are easier to produce and are of a lower cost than CNTs. By monitoring the current produced during the electrochemical oxidation of fentanyl, variables such as fCNF loading, fentanyl accumulation time, electrolyte pH, and differential pulse voltammetry parameters were optimized. Under an optimized set of conditions, the fCNF/SPCEs responded linearly to fentanyl in the concentration range of 0.125-10 μM, with a limit of detection of 75 nM. The fCNF/SPCEs also demonstrated excellent selectivity against common cutting agents found in illicit drugs (e.g., glucose, sucrose, caffeine, acetaminophen, and theophylline) and interferents found in biological samples (e.g., ascorbic acid, NaCl, urea, creatinine, and uric acid). The performance of the sensor was also successfully tested using fentanyl spiked into an artificial urine sample. The straightforward electrode assembly process, low cost, ease of use, and rapid response make the fCNF/SPCEs prime candidates for the detection of fentanyl in both physiological samples and street drugs.
Collapse
Affiliation(s)
- Armando
J. Marenco
- National
Research Council Canada—Nanotechnology Research Centre, 11421 Saskatchewan Drive, Edmonton, Alberta T6G 2M9, Canada
| | - Rajesh G. Pillai
- National
Research Council Canada—Nanotechnology Research Centre, 11421 Saskatchewan Drive, Edmonton, Alberta T6G 2M9, Canada
| | - Kenneth D. Harris
- National
Research Council Canada—Nanotechnology Research Centre, 11421 Saskatchewan Drive, Edmonton, Alberta T6G 2M9, Canada
- Department
of Mechanical Engineering, University of
Alberta, Edmonton, Alberta T6G 1H9, Canada
| | - Nora W. C. Chan
- Defence
Research and Development Canada, Suffield
Research Centre, P.O. Box 4000, Stn. Main, Medicine Hat, Alberta T1A 8K6, Canada
| | - Abebaw B. Jemere
- National
Research Council Canada—Nanotechnology Research Centre, 11421 Saskatchewan Drive, Edmonton, Alberta T6G 2M9, Canada
- Department
of Chemistry, Queen’s University, Kingston, Ontario K7L 3N6, Canada
| |
Collapse
|
5
|
Abdoullateef BMT, El-Din Al-Mofty S, Azzazy HME. Nanoencapsulation of general anaesthetics. NANOSCALE ADVANCES 2024; 6:1361-1373. [PMID: 38419874 PMCID: PMC10898439 DOI: 10.1039/d3na01012k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 01/28/2024] [Indexed: 03/02/2024]
Abstract
General anaesthetics are routinely used to sedate patients during prolonged surgeries and administered via intravenous injection and/or inhalation. All anaesthetics have short half-lives, hence the need for their continuous administration. This causes several side effects such as pain, vomiting, nausea, bradycardia, and on rare occasions death post-administration. Several clinical trials studied the synergetic effect of a combination of anaesthetic drugs to reduce the drug load. Another solution is to encapsulate anaesthetics in nanoparticles to reduce their dose and side effects as well as achieve their sustained release manner. Different types of nanoparticles were developed as carriers of intravenous and intrathecal anaesthetics generating platforms which facilitate drug transport across the blood-brain barrier (BBB). Nanocarriers encapsulating common anaesthetic drugs such as propofol, etomidate, and ketamine were developed and characterized in terms of size, stability, onset and duration of loss of right reflex, and tolerance to pain in small animal models. The review discusses the types of nanocarriers used to reduce the side effects of the anaesthetic drugs while prolonging the sedation time. More rigorous studies are still required to evaluate the nanocarrier formulations regarding their ability to deliver anaesthetic drugs across the BBB, safety, and finally applicability in clinical settings.
Collapse
Affiliation(s)
- Basma M T Abdoullateef
- Department of Chemistry, School of Sciences and Engineering, The American University in Cairo New Cairo, AUC Avenue, SSE # 1184, P.O. Box 74 Cairo 11835 Egypt +20 226152559
| | - Saif El-Din Al-Mofty
- Department of Chemistry, School of Sciences and Engineering, The American University in Cairo New Cairo, AUC Avenue, SSE # 1184, P.O. Box 74 Cairo 11835 Egypt +20 226152559
| | - Hassan M E Azzazy
- Department of Chemistry, School of Sciences and Engineering, The American University in Cairo New Cairo, AUC Avenue, SSE # 1184, P.O. Box 74 Cairo 11835 Egypt +20 226152559
- Department of Nanobiophotonics, Leibniz Institute of Photonic Technology Albert Einstein Str. 9 Jena 07745 Germany
| |
Collapse
|
6
|
Abstract
The monitoring of vital signs in patients undergoing anesthesia began with the very first case of anesthesia and has evolved alongside the development of anesthesiology ever since. Patient monitoring started out as a manually performed, intermittent, and qualitative assessment of the patient's general well-being in the operating room. In its evolution, patient monitoring development has responded to the clinical need, for example, when critical incident studies in the 1980s found that many anesthesia adverse events could be prevented by improved monitoring, especially respiratory monitoring. It also facilitated and perhaps even enabled increasingly complex surgeries in increasingly higher-risk patients. For example, it would be very challenging to perform and provide anesthesia care during some of the very complex cardiovascular surgeries that are almost routine today without being able to simultaneously and reliably monitor multiple pressures in a variety of places in the circulatory system. Of course, anesthesia patient monitoring itself is enabled by technological developments in the world outside of the operating room. Throughout its history, anesthesia patient monitoring has taken advantage of advancements in material science (when nonthrombogenic polymers allowed the design of intravascular catheters, for example), in electronics and transducers, in computers, in displays, in information technology, and so forth. Slower product life cycles in medical devices mean that by carefully observing technologies such as consumer electronics, including user interfaces, it is possible to peek ahead and estimate with confidence the foundational technologies that will be used by patient monitors in the near future. Just as the discipline of anesthesiology has, the patient monitoring that accompanies it has come a long way from its beginnings in the mid-19th century. Extrapolating from careful observations of the prevailing trends that have shaped anesthesia patient monitoring historically, patient monitoring in the future will use noncontact technologies, will predict the trajectory of a patient's vital signs, will add regional vital signs to the current systemic ones, and will facilitate directed and supervised anesthesia care over the broader scope that anesthesia will be responsible for.
Collapse
Affiliation(s)
- Kai Kuck
- From the Departments of Anesthesiology and Biomedical Engineering, University of Utah, Salt Lake City, Utah
| | | | | |
Collapse
|
7
|
Kafley C, K RP, Kummari S, Lakavath K, Kotagiri YG. Ti 3C 2T x-rGO-chitosan-based microcatheter sensor for real-time continuous monitoring of propofol: toward improved anesthetic management. Mikrochim Acta 2023; 190:388. [PMID: 37700189 DOI: 10.1007/s00604-023-05969-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 08/27/2023] [Indexed: 09/14/2023]
Abstract
We are aiming to develop an electrochemical microcatheter sensor for the detection and real-time continuous monitoring of propofol (PPF), which is an anesthetic drug majorly used during medical treatment. This proposed microcatheter-based sensing strategy meets the challenge of real-time periodic and continuous monitoring of propofol by using d-Ti3C2Tx-rGO-chi-modified carbon paste microcatheter sensor transducer. The sensing methodology relies on voltammetry and chronoamperometry transduction methods. The reusable microcatheter sensor was fabricated by embedding the three electrodes into a few millimeters-wide Teflon tube. The nanocomposite was characterized using advanced analytical instruments such as XRD, FE-SEM, EDX, Raman spectroscopy, and XPS. Further, electrode interfacial properties were characterized with voltammetry and electrochemical impedance spectroscopy. The electroanalytical performance of the modified microcatheter sensor was tested for the detection of PPF in phosphate buffer by using chronoamperometry with a wide linear range of 5 to 110 µM (at an applied potential of 0.3 V vs. Ag/AgCl). The sensor's practical potency was confirmed in human serum with a dynamic linear range of 10 to 130 µM. The sensor exhibited a good limit of detection values in phosphate buffer (2 µM) and natural human plasma (4 µM). The new sensor displays different dimensions of information while displaying high sensitivity, selectivity, and long-term stability. The outstanding analytical performance of the developed sensor holds considerable promise for the continuous monitoring of propofol, its effective management, and optimization of the doses in the patient's body.
Collapse
Affiliation(s)
- Chandan Kafley
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad Kerala, 678557, India
| | - Rahul P K
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad Kerala, 678557, India
| | - Shekher Kummari
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad Kerala, 678557, India
| | - Kavitha Lakavath
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad Kerala, 678557, India
| | - Yugender Goud Kotagiri
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad Kerala, 678557, India.
| |
Collapse
|
8
|
Nakhodchi S, Alizadeh N. Dynamic headspace solid-phase extraction at room temperature: a theoretical model, method, and application for propofol analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:1478-1484. [PMID: 36876859 DOI: 10.1039/d2ay02099h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Herein, a simple dynamic headspace solid-phase extraction (DHS-SPE) process at room temperature was used for a material that is sensitive to increase in the temperature. A proposed method was implemented to rapidly extract propofol (PF) from a complex matrix before fluorescence spectroscopy analysis, within a short sampling time without involving a hot plate or stirrer. A mini diaphragm pump was used to circulate the headspace gas. As the headspace gas flows over the sample solution surface, bubbles form and release analytes from the liquid into the headspace. During the extraction process, the headspace gas passes through the coated metal foam as a sorbent that is placed in a homemade glass vessel and analytes are trapped from the gas phase. A theoretical model of DHS-SPE based on the consecutive first-order process is proposed in this study. A mathematical solution for the dynamic process of mass transfer was obtained by correlating the variation in analyte concentration in the headspace and adsorber with the pump speed and amount of analyte extracted to the solid phase. Using electrochemically Nafion-doped polypyrrole (PPy-Naf) film on nickel foam as the solid-phase coupled to fluorescence detection, a linear dynamic range over the concentration range of 100-500 nM with a detection limit of 15 nM was obtained. This method was applied successfully for PF determination in human serum sample matrices without the interference of co-administered drugs, such as cisatracurium, which have significant emission spectrum overlap. The developed method can lead to a new idea for sample pretreatment, which is compatible with many analytical techniques and has been successfully combined with fluorescence spectroscopy in this work. This format of sampling simplifies the transfer of analytes from complex matrices to the headspace for the extraction and preconcentration process, eliminating the heating step and the need for expensive equipment.
Collapse
Affiliation(s)
- Sarah Nakhodchi
- Department of Chemistry, Factually of Basic Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
| | - Naader Alizadeh
- Department of Chemistry, Factually of Basic Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
| |
Collapse
|
9
|
Arjun AM, Krishna PH, Nath AR, Rasheed PA. A review on advances in the development of electrochemical sensors for the detection of anesthetic drugs. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:4040-4052. [PMID: 36173296 DOI: 10.1039/d2ay01290a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Surgeries are a crucial medical intervention that has saved countless lives from time immemorial. To reduce pain during surgeries patients are administered with anesthetic drugs, which cause loss of sensation and thus reduce the pain involved. However, anesthetists control the effects of the drug by depending on pharmacokinetic calculations, which may vary from patient to patient, thus leading to a reduction in the quality of anesthetic care and adverse effects. To avoid these adverse effects, it is highly necessary to implement a real time monitoring of plasma drug concentration, which will adjust the drug infusion and maintain the levels of drug within therapeutic levels. To implement such a system, it is highly essential to analyze current advances in electrochemical sensor systems for different types of anesthetic drugs like opioids, intravenous anesthetics, and neuromuscular blockers. This review focuses on the present strategy of electrochemical sensors implemented for the detection of anesthetic drugs and it helps towards developing a real time drug dispensing system with respect to the plasma concentration of the drug. This analysis will contribute towards establishing highly effective real time drug dispensing systems like the total intravenous anesthesia technique and patient-controlled analgesia. Such systems will lead to better usage of anesthetic drugs and improve the quality of anesthetic care thus making surgeries safer and more painless.
Collapse
Affiliation(s)
- Ajith Mohan Arjun
- Department of Biological Sciences and Engineering, Indian Institute of Technology Palakkad, Palakkad, Kerala, India-678 557.
| | - Prasannakumari H Krishna
- Department of Anaesthesiology, Regional Cancer Center, Medical College Campus, Post Bag No. 2417, Thiruvananthapuram, India 695011
| | - Anish R Nath
- DST Unit on Nanoscience and Thematic Unit of Excellence, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India-600036
| | - P Abdul Rasheed
- Department of Biological Sciences and Engineering, Indian Institute of Technology Palakkad, Palakkad, Kerala, India-678 557.
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad, Kerala, India-678 557
| |
Collapse
|
10
|
Jun D, Sammis G, Rezazadeh-Azar P, Ginoux E, Bizzotto D. Development of a Graphene-Oxide-Deposited Carbon Electrode for the Rapid and Low-Level Detection of Fentanyl and Derivatives. Anal Chem 2022; 94:12706-12714. [PMID: 36082424 PMCID: PMC9494301 DOI: 10.1021/acs.analchem.2c02057] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
![]()
The opioid overdose
crisis in North America worsened during the
COVID-19 pandemic, with multiple jurisdictions reporting more deaths
per day due to the fentanyl-contaminated drug supply than COVID-19.
The rapid quantitative detection of fentanyl in the illicit opioid
drug supply or in bodily fluids at biologically relevant concentrations
(i.e., <80 nM) remains a significant challenge. Electroanalytical
techniques are inexpensive and can be used to rapidly detect fentanyl,
but detection limits need to be improved. Herein, we detail the development
of an electrochemical-based fentanyl analytical detection strategy
that used a glassy carbon electrode modified with electrochemically
reduced graphene oxide (ERGO) via electrophoretic deposition. The
resulting surface was further electrochemically reduced in the presence
of fentanyl to enhance the sensitivity. Multiple ERGO thicknesses
were prepared in order to prove the versatility and ability to fine-tune
the layer to the desired response. Fentanyl was detected at <10
ppb (<30 nM) with a limit of detection of 2 ppb and a calibration
curve that covered 4 orders of concentration (from 1 ppb to 10 ppm).
This method was sensitive to fentanyl analogues such as carfentanil.
Interference from the presence of 100-fold excess of other opioids
(heroin, cocaine) or substances typically found in illicit drug samples
(e.g. caffeine and sucrose) was not significant.
Collapse
Affiliation(s)
- Daniel Jun
- AMPEL, University of British Columbia, Vancouver V6T1Z4, Canada.,Department of Chemistry, University of British Columbia, 2036 Main Mall, Vancouver V6T1Z1, Canada
| | - Glenn Sammis
- Department of Chemistry, University of British Columbia, 2036 Main Mall, Vancouver V6T1Z1, Canada
| | - Pouya Rezazadeh-Azar
- Complex Pain and Addiction Services, Department of Psychiatry, Vancouver General Hospital, Vancouver V5Z 1M9, Canada.,Department of Psychiatry, University of British Columbia, Vancouver V6T2A1, Canada
| | - Erwann Ginoux
- AMPEL, University of British Columbia, Vancouver V6T1Z4, Canada
| | - Dan Bizzotto
- AMPEL, University of British Columbia, Vancouver V6T1Z4, Canada.,Department of Chemistry, University of British Columbia, 2036 Main Mall, Vancouver V6T1Z1, Canada
| |
Collapse
|
11
|
Yence M, Cetinkaya A, Kaya SI, Ozkan SA. Recent Developments in the Sensitive Electrochemical Assay of Common Opioid Drugs. Crit Rev Anal Chem 2022; 54:882-895. [PMID: 35853096 DOI: 10.1080/10408347.2022.2099732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Opioids are a class of drugs used to treat moderate to severe pain and have short-term adverse effects. Nevertheless, they are considered necessary for pain management. However, well-known hazards are connected with an opioid prescription, such as overuse, addiction, and overdose deaths. For example, the death rate from opioid analgesic poisoning in the USA approximately doubled, owing to the overuse and addiction of opioid analgesics. Also, opioids are a very important group of analytes in forensic chemistry, so it is necessary to use reliable, fast, and sensitive analytical tools to determine opioid analgesics. This review focuses on the opioid overdose crisis, the properties of commonly used opioid drugs, their mechanism, effects, and some chromatographic and spectroscopic detection methods are explained briefly. Then most essentially recent developments covering the last ten years in the sensitive electrochemical methods of common opioid analgesics, their innovations and features, and future research directions are presented.
Collapse
Affiliation(s)
- Merve Yence
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - S Irem Kaya
- Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
12
|
Tracking Antioxidant Status in Spinal Cord Injured Rodents: A Voltammetric Method Suited for Clinical Translation. World Neurosurg 2022; 161:e183-e191. [PMID: 35093575 DOI: 10.1016/j.wneu.2022.01.099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 01/22/2022] [Accepted: 01/23/2022] [Indexed: 11/23/2022]
Abstract
BACKGROUND Spinal cord injury (SCI) triggers a signalling cascade that produces oxidative stress and damages the spinal cord. Voltammetry is a clinically accessible technique to detect, monitor, and guide correction of this potentially reversible secondary injury mechanism. Voltammetry is well suited for clinical translation because the method is inexpensive, simple, rapid, and portable. Voltammetry relies on the measurement of anodic current from a reagent-free, electrochemical reaction on the surface of a small electrode. METHODS The present study tested the use of new disposable carbon nanotube based screen printed electrodes (CNT-SPE) for the voltammetric measurement of antioxidant current (AC). Spinal cord, cerebrospinal fluid, and plasma were obtained from Sprague-Dawley rats after SCI. Locomotor function after SCI was assessed by using the Basso, Beattie, Bresnahan (BBB) score. RESULTS The more severe SCI caused a decline in spinal cord AC419 at 10 minutes (P < 0.05), 4 hours (P < 0.0001), and 1 day (P < 0.01) after injury compared with sham controls. It also caused a decline in plasma AC375 at 1 (P < 0.001) and 3 days (P < 0.05) after injury compared with their pre-injury baseline. Spinal cord AC419 correlated with plasma AC375 (r = 0.49, P < 0.01) and BBB score (r = 0.66, P < 0.0001) at 1 day after SCI. CONCLUSIONS AC measured by CNT-SPE demonstrated a time- and severity-dependent decline after SCI. Plasma AC could serve as a surrogate marker for spinal cord AC.
Collapse
|
13
|
Choińska MK, Šestáková I, Hrdlička V, Skopalová J, Langmaier J, Maier V, Navrátil T. Electroanalysis of Fentanyl and Its New Analogs: A Review. BIOSENSORS 2022; 12:bios12010026. [PMID: 35049654 PMCID: PMC8774265 DOI: 10.3390/bios12010026] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 12/25/2021] [Accepted: 12/30/2021] [Indexed: 11/16/2022]
Abstract
The review describes fentanyl and its analogs as new synthetic opioids and the possibilities of their identification and determination using electrochemical methods (e.g., voltammetry, potentiometry, electrochemiluminescence) and electrochemical methods combined with various separation methods. The review also covers the analysis of new synthetic opioids, their parent compounds, and corresponding metabolites in body fluids, such as urine, blood, serum, and plasma, necessary for a fast and accurate diagnosis of intoxication. Identifying and quantifying these addictive and illicit substances and their metabolites is necessary for clinical, toxicological, and forensic purposes. As a reaction to the growing number of new synthetic opioid intoxications and increasing fatalities observed over the past ten years, we provide thorough background for developing new biosensors, screen-printed electrodes, or other point-of-care devices.
Collapse
Affiliation(s)
- Marta Katarzyna Choińska
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23 Prague, Czech Republic; (M.K.C.); (V.H.); (J.L.); (T.N.)
- UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Albertov 6, 128 43 Prague, Czech Republic
| | - Ivana Šestáková
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23 Prague, Czech Republic; (M.K.C.); (V.H.); (J.L.); (T.N.)
- Correspondence: (I.Š.); (J.S.); Tel.: +420-266-053-875 (I.Š.); +420-585-634-442 (J.S.)
| | - Vojtěch Hrdlička
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23 Prague, Czech Republic; (M.K.C.); (V.H.); (J.L.); (T.N.)
| | - Jana Skopalová
- Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, 17. Listopadu 12, 771 46 Olomouc, Czech Republic;
- Correspondence: (I.Š.); (J.S.); Tel.: +420-266-053-875 (I.Š.); +420-585-634-442 (J.S.)
| | - Jan Langmaier
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23 Prague, Czech Republic; (M.K.C.); (V.H.); (J.L.); (T.N.)
| | - Vítězslav Maier
- Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, 17. Listopadu 12, 771 46 Olomouc, Czech Republic;
| | - Tomáš Navrátil
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23 Prague, Czech Republic; (M.K.C.); (V.H.); (J.L.); (T.N.)
| |
Collapse
|
14
|
Rivkin B, Becker C, Singh B, Aziz A, Akbar F, Egunov A, Karnaushenko DD, Naumann R, Schäfer R, Medina-Sánchez M, Karnaushenko D, Schmidt OG. Electronically integrated microcatheters based on self-assembling polymer films. SCIENCE ADVANCES 2021; 7:eabl5408. [PMID: 34919439 PMCID: PMC8682992 DOI: 10.1126/sciadv.abl5408] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Accepted: 11/02/2021] [Indexed: 05/22/2023]
Abstract
Existing electronically integrated catheters rely on the manual assembly of separate components to integrate sensing and actuation capabilities. This strongly impedes their miniaturization and further integration. Here, we report an electronically integrated self-assembled microcatheter. Electronic components for sensing and actuation are embedded into the catheter wall through the self-assembly of photolithographically processed polymer thin films. With a diameter of only about 0.1 mm, the catheter integrates actuated digits for manipulation and a magnetic sensor for navigation and is capable of targeted delivery of liquids. Fundamental functionalities are demonstrated and evaluated with artificial model environments and ex vivo tissue. Using the integrated magnetic sensor, we develop a strategy for the magnetic tracking of medical tools that facilitates basic navigation with a high resolution below 0.1 mm. These highly flexible and microsized integrated catheters might expand the boundary of minimally invasive surgery and lead to new biomedical applications.
Collapse
Affiliation(s)
- Boris Rivkin
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
| | - Christian Becker
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
| | - Balram Singh
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
| | - Azaam Aziz
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
| | - Farzin Akbar
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
| | - Aleksandr Egunov
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
| | - Dmitriy D. Karnaushenko
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
| | - Ronald Naumann
- Max Planck Institute of Molecular Cell Biology and Genetics, Transgenic Core Facility, Pfotenhauerstrasse 108, 01307 Dresden, Germany
| | - Rudolf Schäfer
- Institute for Metallic Materials, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
| | - Mariana Medina-Sánchez
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
- Corresponding author. (M.M.-S.); (D.K.); (O.G.S.)
| | - Daniil Karnaushenko
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
- Corresponding author. (M.M.-S.); (D.K.); (O.G.S.)
| | - Oliver G. Schmidt
- Institute for Integrative Nanosciences, Institute for Solid State and Materials Research Dresden (Leibniz IFW Dresden), 01069 Dresden, Germany
- Material Systems for Nanoelectronics, Chemnitz University of Technology, 09107 Chemnitz, Germany
- Research Center for Materials, Architectures and Integration of Nanomembranes (MAIN), Rosenbergstraße 6, TU Chemnitz, 09126 Chemnitz, Germany
- Nanophysics, Faculty of Physics, TU Dresden, 01062 Dresden, Germany
- Corresponding author. (M.M.-S.); (D.K.); (O.G.S.)
| |
Collapse
|
15
|
Gomes NO, Mendonça CD, Machado SAS, Oliveira ON, Raymundo-Pereira PA. Flexible and integrated dual carbon sensor for multiplexed detection of nonylphenol and paroxetine in tap water samples. Mikrochim Acta 2021; 188:359. [PMID: 34599426 DOI: 10.1007/s00604-021-05024-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 09/10/2021] [Indexed: 11/28/2022]
Abstract
Multiplex detection of emerging pollutants is essential to improve quality control of water treatment plants, which requires portable systems capable of real-time monitoring. In this paper we describe a flexible, dual electrochemical sensing device that detects nonylphenol and paroxetine in tap water samples. The platform contains two voltammetric sensors, with different working electrodes that were either pretreated or functionalized. Each working electrode was judiciously tailored to cover the concentration range of interest for nonylphenol and paroxetine, and square wave voltammetry was used for detection. An electrochemical pretreatment with sulfuric acid on the printed electrode enabled a selective detection of nonylphenol in 1.0-10 × 10-6 mol L-1 range with a limit of detection of 8.0 × 10-7 mol L-1. Paroxetine was detected in the same range with a limit of detection of 6.7 × 10-7 mol L-1 using the printed electrode coated with a layer of carbon spherical shells. Simultaneous detection of the two analytes was achieved in tap water samples within 1 min, with no fouling and no interference effects. The long-term monitoring capability of the dual sensor was demonstrated in phosphate buffer for 45 days. This performance is statistically equivalent to that of high-performance liquid chromatography (HPLC) for water analysis. The dual-sensor platform is generic and may be extended to other water pollutants and clinical biomarkers in real-time monitoring of the environment and health conditions. Silver pseudo-reference electrodes for paroxetine (REP) and nonylphenol (REN), working electrodes for paroxetine (WP) and nonylphenol (WN), and auxiliary electrode (AE). USP refers to the University of Sao Paulo. "Red" is reduced form and "Oxi" is oxidized form of analytes.
Collapse
Affiliation(s)
- Nathalia O Gomes
- São Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP, CEP 13566-590, Brazil
| | - Camila D Mendonça
- São Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP, CEP 13566-590, Brazil
| | - Sergio A S Machado
- São Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP, CEP 13566-590, Brazil
| | - Osvaldo N Oliveira
- São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, CEP 13560-970, Brazil
| | - Paulo A Raymundo-Pereira
- São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, CEP 13560-970, Brazil.
| |
Collapse
|
16
|
Cohen R, Bitton RE, Herzallh NS, Cohen Y, Yehezkeli O. Utilization of FAD-Glucose Dehydrogenase from T. emersonii for Amperometric Biosensing and Biofuel Cell Devices. Anal Chem 2021; 93:11585-11591. [PMID: 34383460 PMCID: PMC8631703 DOI: 10.1021/acs.analchem.1c02157] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Accepted: 08/02/2021] [Indexed: 11/29/2022]
Abstract
Flavin-dependent glucose dehydrogenases (FAD-GDH) are oxygen-independent enzymes with high potential to be used as biocatalysts in glucose biosensing applications. Here, we present the construction of an amperometric biosensor and a biofuel cell device, which are based on a thermophilic variant of the enzyme originated from Talaromyces emersonii. The enzyme overexpression in Escherichia coli and its isolation and performance in terms of maximal bioelectrocatalytic currents were evaluated. We examined the biosensor's bioelectrocatalytic activity in 2,6-dichlorophenolindophenol-, thionine-, and dichloro-naphthoquinone-mediated electron transfer configurations or in a direct electron transfer one. We showed a negligible interference effect and good stability for at least 20 h for the dichloro-naphthoquinone configuration. The constructed biosensor was also tested in interstitial fluid-like solutions to show high bioelectrocatalytic current responses. The bioanode was coupled with a bilirubin oxidase-based biocathode to generate 270 μW/cm2 in a biofuel cell device.
Collapse
Affiliation(s)
- Roy Cohen
- Faculty
of Biotechnology and Food Engineering, Technion—Israel
Institute of Technology, Haifa 3200003, Israel
| | - Rachel E. Bitton
- Faculty
of Biotechnology and Food Engineering, Technion—Israel
Institute of Technology, Haifa 3200003, Israel
| | - Nidaa S. Herzallh
- Faculty
of Biotechnology and Food Engineering, Technion—Israel
Institute of Technology, Haifa 3200003, Israel
| | - Yifat Cohen
- Faculty
of Biotechnology and Food Engineering, Technion—Israel
Institute of Technology, Haifa 3200003, Israel
| | - Omer Yehezkeli
- Faculty
of Biotechnology and Food Engineering, Technion—Israel
Institute of Technology, Haifa 3200003, Israel
- Russell
Berrie Nanotechnology Institute, Technion—Israel
Institute of Technology, Haifa 3200003, Israel
- The
Nancy and Stephen Grand Technion Energy Program, Technion—Israel Institute of Technology, Haifa 3200003, Israel
| |
Collapse
|
17
|
Verrinder E, Wester N, Leppänen E, Lilius T, Kalso E, Mikladal B, Varjos I, Koskinen J, Laurila T. Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood. ACS OMEGA 2021; 6:11563-11569. [PMID: 34056312 PMCID: PMC8154029 DOI: 10.1021/acsomega.1c00773] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 04/06/2021] [Indexed: 05/04/2023]
Abstract
Disposable single-use electrochemical sensor strips were used for quantitative detection of small concentrations of morphine in untreated capillary whole blood. Single-walled carbon nanotube (SWCNT) networks were fabricated on a polymer substrate to produce flexible, reproducible sensor strips with integrated reference and counter electrodes, compatible with industrial-scale processes. A thin Nafion coating was used on top of the sensors to enable direct electrochemical detection in whole blood. These sensors were shown to detect clinically relevant concentrations of morphine both in buffer and in whole blood samples. Small 38 μL finger-prick blood samples were spiked with 2 μL of morphine solution of several concentrations and measured without precipitation of proteins or any other further pretreatment. A linear range of 0.5-10 μM was achieved in both matrices and a detection limit of 0.48 μM in buffer. In addition, to demonstrate the applicability of the sensor in a point-of-care device, single-determination measurements were done with capillary samples from three subjects. An average recovery of 60% was found, suggesting that the sensor only measures the free, unbound fraction of the drug. An interference study with other opioids and possible interferents showed the selectivity of the sensor. This study clearly indicates that these Nafion/SWCNT sensor strips show great promise as a point-of-care rapid test for morphine in blood.
Collapse
Affiliation(s)
- Elsi Verrinder
- Department
of Electrical Engineering and Automation, Aalto University, Tietotie 3, Espoo 02150, Finland
| | - Niklas Wester
- Department
of Chemistry and Materials Science, Aalto
University, Kemistintie
1, Espoo 02150, Finland
| | - Elli Leppänen
- Department
of Electrical Engineering and Automation, Aalto University, Tietotie 3, Espoo 02150, Finland
| | - Tuomas Lilius
- Department
of Pharmacology, University of Helsinki, Haartmaninkatu 8, Helsinki 00290, Finland
- Department
of Clinical Pharmacology, University of
Helsinki and Helsinki University Hospital, Tukholmankatu 8C, Helsinki 00290, Finland
- Emergency
Medicine, University of Helsinki and Department of Emergency Medicine
and Services, Helsinki University Hospital, Helsinki 00014, Finland
| | - Eija Kalso
- Department
of Pharmacology, University of Helsinki, Haartmaninkatu 8, Helsinki 00290, Finland
- Department
of Anesthesiology, Intensive Care and Pain Medicine, University of Helsinki and Helsinki University Hospital, Haartmaninkatu 2A, Helsinki 00290, Finland
| | | | - Ilkka Varjos
- Canatu
Oy, Tiilenlyöjänkuja 9, Vantaa 01720, Finland
| | - Jari Koskinen
- Department
of Chemistry and Materials Science, Aalto
University, Kemistintie
1, Espoo 02150, Finland
| | - Tomi Laurila
- Department
of Electrical Engineering and Automation, Aalto University, Tietotie 3, Espoo 02150, Finland
- Department
of Chemistry and Materials Science, Aalto
University, Kemistintie
1, Espoo 02150, Finland
| |
Collapse
|
18
|
Clifford A, Das J, Yousefi H, Mahmud A, Chen JB, Kelley SO. Strategies for Biomolecular Analysis and Continuous Physiological Monitoring. J Am Chem Soc 2021; 143:5281-5294. [PMID: 33793215 DOI: 10.1021/jacs.0c13138] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Portable devices capable of rapid disease detection and health monitoring are crucial to decentralizing diagnostics from clinical laboratories to the patient point-of-need. Although technologies have been developed targeting this challenge, many require the use of reporter molecules or reagents that complicate the automation and autonomy of sensors. New work in the field has targeted reagentless approaches to enable breakthroughs that will allow personalized monitoring of a wide range of biomarkers on demand. This Perspective focuses on the ability of reagentless platforms to revolutionize the field of sensing by allowing rapid and real-time analysis in resource-poor settings. First, we will highlight advantages of reagentless sensing techniques, specifically electrochemical detection strategies. Advances in this field, including the development of wearable and in situ sensors capable of real-time monitoring of biomarkers such as nucleic acids, proteins, viral particles, bacteria, therapeutic agents, and metabolites, will be discussed. Reagentless platforms which allow for wash-free, calibration free-detection with increased dynamic range are highlighted as a key technological advance for autonomous sensing applications. Furthermore, we will highlight remaining challenges which must be overcome to enable widespread use of reagentless devices. Finally, future prospects and potential breakthroughs in precision medicine that will arise as a result of further development of reagentless sensing approaches are discussed.
Collapse
Affiliation(s)
- Amanda Clifford
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Ontario M5S 3M2, Canada
| | - Jagotamoy Das
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Ontario M5S 3M2, Canada
| | - Hanie Yousefi
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Ontario M5S 3M2, Canada
| | - Alam Mahmud
- The Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, Toronto, Ontario M5S 3G4, Canada
| | - Jenise B Chen
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | - Shana O Kelley
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Ontario M5S 3M2, Canada
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
- Institute for Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3G9, Canada
| |
Collapse
|
19
|
Yáñez-Sedeño P, González-Cortés A, Campuzano S, Pingarrón JM. Multimodal/Multifunctional Nanomaterials in (Bio)electrochemistry: Now and in the Coming Decade. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E2556. [PMID: 33352731 PMCID: PMC7766190 DOI: 10.3390/nano10122556] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 12/13/2020] [Accepted: 12/16/2020] [Indexed: 01/15/2023]
Abstract
Multifunctional nanomaterials, defined as those able to achieve a combined effect or more than one function through their multiple functionalization or combination with other materials, are gaining increasing attention in the last years in many relevant fields, including cargo targeted delivery, tissue engineering, in vitro and/or in vivo diseases imaging and therapy, as well as in the development of electrochemical (bio)sensors and (bio)sensing strategies with improved performance. This review article aims to provide an updated overview of the important advances and future opportunities exhibited by electrochemical biosensing in connection to multifunctional nanomaterials. Accordingly, representative aspects of recent approaches involving metal, carbon, and silica-based multifunctional nanomaterials are selected and critically discussed, as they are the most widely used multifunctional nanomaterials imparting unique capabilities in (bio)electroanalysis. A brief overview of the main remaining challenges and future perspectives in the field is also provided.
Collapse
Affiliation(s)
- Paloma Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (A.G.-C.); (J.M.P.)
| | | | - Susana Campuzano
- Departamento de Química Analítica, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (A.G.-C.); (J.M.P.)
| | | |
Collapse
|
20
|
Teymourian H, Parrilla M, Sempionatto JR, Montiel NF, Barfidokht A, Van Echelpoel R, De Wael K, Wang J. Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs. ACS Sens 2020; 5:2679-2700. [PMID: 32822166 DOI: 10.1021/acssensors.0c01318] [Citation(s) in RCA: 175] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Wearable electrochemical sensors capable of noninvasive monitoring of chemical markers represent a rapidly emerging digital-health technology. Recent advances toward wearable continuous glucose monitoring (CGM) systems have ignited tremendous interest in expanding such sensor technology to other important fields. This article reviews for the first time wearable electrochemical sensors for monitoring therapeutic drugs and drugs of abuse. This rapidly emerging class of drug-sensing wearable devices addresses the growing demand for personalized medicine, toward improved therapeutic outcomes while minimizing the side effects of drugs and the related medical expenses. Continuous, noninvasive monitoring of therapeutic drugs within bodily fluids empowers clinicians and patients to correlate the pharmacokinetic properties with optimal outcomes by realizing patient-specific dose regulation and tracking dynamic changes in pharmacokinetics behavior while assuring the medication adherence of patients. Furthermore, wearable electrochemical drug monitoring devices can also serve as powerful screening tools in the hands of law enforcement agents to combat drug trafficking and support on-site forensic investigations. The review covers various wearable form factors developed for noninvasive monitoring of therapeutic drugs in different body fluids and toward on-site screening of drugs of abuse. The future prospects of such wearable drug monitoring devices are presented with the ultimate goals of introducing accurate real-time drug monitoring protocols and autonomous closed-loop platforms toward precise dose regulation and optimal therapeutic outcomes. Finally, current unmet challenges and existing gaps are discussed for motivating future technological innovations regarding personalized therapy. The current pace of developments and the tremendous market opportunities for such wearable drug monitoring platforms are expected to drive intense future research and commercialization efforts.
Collapse
Affiliation(s)
- Hazhir Teymourian
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Marc Parrilla
- AXES Research Group, Bioscience Engineering Department, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Juliane R. Sempionatto
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Noelia Felipe Montiel
- AXES Research Group, Bioscience Engineering Department, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Abbas Barfidokht
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Robin Van Echelpoel
- AXES Research Group, Bioscience Engineering Department, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Karolien De Wael
- AXES Research Group, Bioscience Engineering Department, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Joseph Wang
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| |
Collapse
|