1
|
Daruwala KD, Baskaran KV. Detection of ninhydrin-glyphosate in groundwater via the colour chart-assisted digital camera method. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 339:126253. [PMID: 40273772 DOI: 10.1016/j.saa.2025.126253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2025] [Revised: 04/15/2025] [Accepted: 04/16/2025] [Indexed: 04/26/2025]
Abstract
This study introduces a novel application of a one-time and multistandard colour chart across three instruments using colour visible spectrophotometer (colour VS), digital single-lens reflex (DSLR) cameras, and mobile camera (MC) analysis to quantify glyphosate (GP) in groundwater samples. The image captured by the digital cameras and the absorbance of the colour VS data of the ninhydrin-GP complexation reaction of the standards were detected by the colour space of the human eye model. The colour ranges were from yellow to brown (colour VS) and red (digital cameras). The results of MC provided enhanced luminance and appropriate ΔE levels, with similar relative standard deviations (RSD) to those of colour VS. The deviations for DSLR were greater and showed better theoretical detection levels. The recovery yield analysis of real-time ground water samples at 50-500 ng/mL in 75 mL was greater for the DSLR (116 %). This method was better than liquid chromatography-tandem mass spectrometry (LC-MS/MS) and MC analysis. However, the MC and LC-MS/MS methods were better in terms of accuracy (98.9 % and 84 % respectively) and precision (99.9 % for both) closeness in a 1:1 linear analytical comparison. The DSLR overestimated the concentrations due to ion interference. However, MC showed no interfering ions at 500 µg/mL due to its unique LED flash light, unlike colour VS, which was affected by phosphate and nitrate. This study was able to achieve real-time monitoring via cost-effective, user-friendly point-of-care technology, eliminating the need for expensive sensor fabrication and repeated standardisation methods. This might pave the way for possible integration of artificial intelligence, machine learning and deep learning models using colour chart data. Therefore, the our multistandard colour chart may also assist in standardizing other camera sensors through harmonization approach.
Collapse
Affiliation(s)
- Kainaz Dhanjisha Daruwala
- Dr. K.C.Patel Research and Development Centre, Charotar University of Science and Technology, Anand, Gujarat, India; P.D.Patel Institute of Applied Sciences, Charotar University of Science and Technology, Anand, Gujarat, India
| | - Kamesh Viswanathan Baskaran
- Dr. K.C.Patel Research and Development Centre, Charotar University of Science and Technology, Anand, Gujarat, India.
| |
Collapse
|
2
|
Deng K, Guo H, Li X, Li T, Di T, Ma R, Lei D, Zhang Y, Wang J, Kong W. Two swords combination: Smartphone-assisted ratiometric fluorescent and paper sensors for dual-mode detection of glyphosate in edible malt. Food Chem 2024; 454:139744. [PMID: 38797096 DOI: 10.1016/j.foodchem.2024.139744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 05/11/2024] [Accepted: 05/17/2024] [Indexed: 05/29/2024]
Abstract
The long-term and excessive use of glyphosate (GLY) in diverse matrices has caused serious hazard to the human and environment. However, the ultrasensitive detection of GLY still remains challenging. In this study, the smartphone-assisted dual-signal mode ratiometric fluorescent and paper sensors based on the red-emissive gold nanoclusters (R-AuNCs) and blue-emissive carbon dots (B-CDs) were ingeniously designed accurate and sensitive detection of GLY. Upon the presence of GLY, it would quench the fluorescence of B-CDs through dynamic quenching effect, and strengthen the fluorescence response of R-AuNCs due to aggregation-induced enhancement effect. Through calculating the GLY-induced fluorescence intensity ratio of B-CDs to R-AuNCs by using a fluorescence spectrophotometer, low to 0.218 μg/mL of GLY could be detected in lab in a wide concentration range of 0.3-12 μg/mL with high recovery of 94.7-103.1% in the spiked malt samples. The smartphone-assisted ratiometric fluorescent sensor achieved in the 96-well plate could monitor 0-11 μg/mL of GLY with satisfactory recovery of 94.1-107.0% in real edible malt matrices for high-throughput analysis. In addition, a portable smartphone-assisted ratiometric paper sensor established through directly depositing the combined B-CDs/R-AuNCs probes on the test strip could realize on-site measurement of 2-8 μg/mL of GLY with good linear relationship. This study provides new insights into developing the dual-signal ratiometric sensing platforms for the in-lab sensitive detection, high-throughput analysis, and on-site portable measurement of more trace contaminants in foods, clinical and environmental samples.
Collapse
Affiliation(s)
- Kai Deng
- School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China
| | - Haipeng Guo
- State Key Laboratory of Southwestern Chinese Medicine Resources, Pharmacy College, Chengdu University of Traditional Chinese Medicine, Chengdu 611137, China
| | - Xueying Li
- School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China
| | - Te Li
- School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China
| | - Tingting Di
- Beijing Hospital of Traditional Chinese Medicine, Capital Medical University, Beijing Institute of Traditional Chinese Medicine, Beijing 100010, China
| | - Runran Ma
- School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China
| | - Doudou Lei
- State Key Laboratory of Southwestern Chinese Medicine Resources, Pharmacy College, Chengdu University of Traditional Chinese Medicine, Chengdu 611137, China
| | - Yining Zhang
- School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China
| | - Jiabo Wang
- School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China
| | - Weijun Kong
- School of Traditional Chinese Medicine, Capital Medical University, Beijing 100069, China; Laboratory for Clinical Medicine, Capital Medical University, Beijing 100069, China.
| |
Collapse
|
3
|
Jared NM, Johnson ZT, Pola CC, Bez KK, Bez K, Hooe SL, Breger JC, Smith EA, Medintz IL, Neihart NM, Claussen JC. Biomimetic laser-induced graphene fern leaf and enzymatic biosensor for pesticide spray collection and monitoring. NANOSCALE HORIZONS 2024; 9:1543-1556. [PMID: 38985448 DOI: 10.1039/d4nh00010b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/11/2024]
Abstract
Monitoring of pesticide concentration distribution across farm fields is crucial to ensure precise and efficient application while preventing overuse or untreated areas. Inspired by nature's wettability patterns, we developed a biomimetic fern leaf pesticide collection patch using laser-induced graphene (LIG) alongside an external electrochemical LIG biosensor. This "collect-and-sense" system allows for rapid pesticide spray monitoring in the farm field. The LIG is synthesized and patterned on polyimide through a high-throughput gantry-based CO2 laser process, making it amenable to scalable manufacturing. The resulting LIG-based leaf exhibits a remarkable water collection capacity, harvesting spray mist/fog at a rate approximately 11 times greater than a natural ostrich fern leaf when the collection is normalized to surface area. The developed three-electrode LIG pesticide biosensor, featuring a working electrode functionalized with electrodeposited platinum nanoparticles (PtNPs) and the enzyme glycine oxidase, displayed a linear range of 10-260 μM, a detection limit of 1.15 μM, and a sensitivity of 5.64 nA μM-1 for the widely used herbicide glyphosate. Also, a portable potentiostat with a user-friendly interface was developed for remote operation, achieving an accuracy of up to 97%, when compared to a standard commercial benchtop potentiostat. The LIG "collect-and-sense" system can consistently collect and monitor glyphosate spray after 24-48 hours of spraying, a time that corresponds to the restricted-entry interval required to enter most farm fields after pesticide spraying. Hence, this innovative "collect-and-sense" system not only advances precision agriculture by enabling monitoring and mapping of pesticide distribution but also holds the potential to significantly reduce environmental impact, enhance crop management practices, and contribute to the sustainable and efficient use of agrochemicals in modern agriculture.
Collapse
Affiliation(s)
- Nathan M Jared
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, USA.
| | - Zachary T Johnson
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, USA.
| | - Cicero C Pola
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, USA.
| | - Kristi K Bez
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, USA.
| | - Krishangee Bez
- Department of Chemistry, Iowa State University, Ames, Iowa 50011, USA
| | - Shelby L Hooe
- Center for Bio/Molecular Science and Engineering, Code 6900, Naval Research Laboratory, Washington, DC 20375, USA
| | - Joyce C Breger
- Center for Bio/Molecular Science and Engineering, Code 6900, Naval Research Laboratory, Washington, DC 20375, USA
| | - Emily A Smith
- Department of Chemistry, Iowa State University, Ames, Iowa 50011, USA
| | - Igor L Medintz
- Center for Bio/Molecular Science and Engineering, Code 6900, Naval Research Laboratory, Washington, DC 20375, USA
| | - Nathan M Neihart
- Department of Electrical Engineering, Iowa State University, Ames, Iowa 50011, USA
| | - Jonathan C Claussen
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, USA.
| |
Collapse
|
4
|
Che S, Zhuge Y, Shao X, Peng X, Fu H, She Y. A fluorescence ionic probe utilizing Cu 2+ assisted competition for detecting glyphosate abused in green tea. Food Chem 2024; 447:138859. [PMID: 38479145 DOI: 10.1016/j.foodchem.2024.138859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/16/2024] [Accepted: 02/24/2024] [Indexed: 04/10/2024]
Abstract
Food fraud caused by the violation of glyphosate use in tea is frequently exposed, posing a potential health risk to consumers and undermining trust in food safety. In the work, an ionic fluorescent probe "[P66614] [4HQCA]-Cu2+ (PHQCA-Cu2+)" was constructed using Cu2+ and ionic liquids coordination through a competitive coordination strategy to detect glyphosate. This probe exhibited a prominent "turn-on" fluorescence response in glyphosate detection. PHQCA-Cu2+was destroyed by glyphosate with its strong coordination capability, and a new complex re-formed simultaneously between glyphosate and the Cu2+ in it, where Cu2+ served as an "invisible indicator" influencing fluorescence changes. Remarkably, PHQCA-Cu2+formed rapidly within 5 s, demonstrated exceptional sensitivity and selectivity, and satisfactory detection performance on paper strips impregnated withPHQCA-Cu2+.Importantly,PHQCA-Cu2+showed excellent recoveries in various green tea, which offered a viable method for identifying contaminated products from the supply chain quickly to enhance overall food safety surveillance.
Collapse
Affiliation(s)
- Siying Che
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China
| | - Yiwan Zhuge
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China
| | - Xinxiang Shao
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China
| | - Xiutan Peng
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China
| | - Haiyan Fu
- College of Pharmacy, South-Central University for Nationalities, Wuhan 430074, China
| | - Yuanbin She
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China.
| |
Collapse
|
5
|
Jiang W, Tang Q, Zhu Y, Gu X, Wu L, Qin Y. Research progress of microfluidics-based food safety detection. Food Chem 2024; 441:138319. [PMID: 38218144 DOI: 10.1016/j.foodchem.2023.138319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/17/2023] [Accepted: 12/27/2023] [Indexed: 01/15/2024]
Abstract
High demands for food safety detection and analysis have been advocated with people's increasing living standards. Even though numerous analytical testing techniques have been proposed, their widespread adoption is still constrained by the high limit of detection, narrow detection ranges, and high implementation costs. Due to their advantages, such as reduced sample and reagent consumption, high sensitivity, automation, low cost, and portability, using microfluidic devices for food safety monitoring has generated significant interest. This review provides a comprehensive overview of the latest microfluidic detection platforms (published in recent 4 years) and their applications in food safety, aiming to provide references for developing efficient research strategies for food contaminant detection and facilitating the transition of these platforms from laboratory research to practical field use.
Collapse
Affiliation(s)
- Wenjun Jiang
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China
| | - Qu Tang
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China
| | - Yidan Zhu
- Medical School, Nantong University, Nantong, Jiangsu 226001, PR China
| | - Xijuan Gu
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China
| | - Li Wu
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China; School of Life Science, Nantong University, Nantong, Jiangsu 226001, PR China.
| | - Yuling Qin
- Nantong Key Laboratory of Public Health and Medical Analysis, School of Public Health, Nantong University, Nantong, Jiangsu 226019, PR China.
| |
Collapse
|
6
|
Soman SS, Samad SA, Venugopalan P, Kumawat N, Kumar S. Microfluidic paper analytic device (μPAD) technology for food safety applications. BIOMICROFLUIDICS 2024; 18:031501. [PMID: 38706979 PMCID: PMC11068414 DOI: 10.1063/5.0192295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 04/15/2024] [Indexed: 05/07/2024]
Abstract
Foodborne pathogens, food adulterants, allergens, and toxic chemicals in food can cause major health hazards to humans and animals. Stringent quality control measures at all stages of food processing are required to ensure food safety. There is, therefore, a global need for affordable, reliable, and rapid tests that can be conducted at different process steps and processing sites, spanning the range from the sourcing of food to the end-product acquired by the consumer. Current laboratory-based food quality control tests are well established, but many are not suitable for rapid on-site investigations and are costly. Microfluidic paper analytical devices (μPADs) are a fast-growing field in medical diagnostics that can fill these gaps. In this review, we describe the latest developments in the applications of microfluidic paper analytic device (μPAD) technology in the food safety sector. State-of-the-art μPAD designs and fabrication methods, microfluidic assay principles, and various types of μPAD devices with food-specific applications are discussed. We have identified the prominent research and development trends and future directions for maximizing the value of microfluidic technology in the food sector and have highlighted key areas for improvement. We conclude that the μPAD technology is promising in food safety applications by using novel materials and improved methods to enhance the sensitivity and specificity of the assays, with low cost.
Collapse
Affiliation(s)
- Soja Saghar Soman
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, UAE
| | - Shafeek Abdul Samad
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, UAE
| | | | - Nityanand Kumawat
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, P.O. Box 129188, UAE
| | | |
Collapse
|
7
|
Boontongto T, Santaladchaiyakit Y, Burakham R. Molecularly imprinted polymer-coated paper for the selective extraction of organophosphorus pesticides from fruits, vegetables, and cereal grains. Talanta 2024; 270:125536. [PMID: 38101032 DOI: 10.1016/j.talanta.2023.125536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 12/02/2023] [Accepted: 12/06/2023] [Indexed: 12/17/2023]
Abstract
Biodegradable molecularly imprinted polymer-coated paper (MIP@paper) was effectively produced by polymerization using azinphos-methyl as a template molecule, terephthalic acid as a functional monomer, ethylene glycol dimethacrylate as a cross-linker, and aqueous ethanol as a green porogenic solvent. The material was subsequently composited onto cellulose paper, which served as the natural substrate, by dip coating with the aid of chitosan and citric acid natural adhesive. The properties, such as static and dynamic adsorption, selectivity, and reusability, were assessed. At rapid adsorption equilibrium (10 min), the MIP@paper had a high adsorption capacity in the range of 2.5-3.7 mg g-1 and good recognition with imprinting factors up to 2.1. In addition, the proposed MIP@paper was utilized efficiently as a sorbent for dispersive solid phase extraction (d-SPE) of eight organophosphorus pesticides (OPPs) prior to high-performance liquid chromatography (HPLC) analysis. The d-SPE-HPLC method displayed low detection limits of 1.2-4.5 μg kg-1 and significant enrichment factors (up to 320-fold). The proposed method was effectively applied for the determination of OPP residues in agricultural products, including fruits, vegetables, and cereal grains, with satisfactory spiked recoveries (80.1-119.1 %). Thus, the MIP@paper material provided a selective and environmentally favorable method for extracting and determining organophosphorus pesticides.
Collapse
Affiliation(s)
- Tittaya Boontongto
- Materials Chemistry Research Center, Department of Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Yanawath Santaladchaiyakit
- Department of Chemistry, Faculty of Engineering, Rajamangala University of Technology Isan, Khon Kaen Campus, Khon Kaen 40000, Thailand
| | - Rodjana Burakham
- Materials Chemistry Research Center, Department of Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand.
| |
Collapse
|
8
|
Yang CL, Yu LH, Pang YH, Shen XF. A colorimetric sensing platform with smartphone for organophosphorus pesticides detection based on PANI-MnO 2 nanozyme. Anal Chim Acta 2024; 1286:342045. [PMID: 38049237 DOI: 10.1016/j.aca.2023.342045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/15/2023] [Accepted: 11/17/2023] [Indexed: 12/06/2023]
Abstract
Organophosphorus pesticides (OPs) are of great concern due to its potential harms on human health and the environment. Herein, a budget-friendly, rapid and convenient colorimetric sensing platform is developed for detection of OPs in the environmental and food samples. The sensing element, PANI-MnO2 nanozyme with excellent oxidase mimetic activity is synthesized at room temperature, which is able to directly oxidize 3,3,5,5-tetramethylbenzidine (TMB) to generate blue colored oxidized TMB (OxTMB) within 2 min. Ascorbic acid (AA) can inhibit the oxidization reaction of TMB, consequently causing the blue color fading. Ascorbic acid 2-phosphate (AAP) could be hydrolyzed to produce AA by alkaline phosphatase (ALP). In the presence of OPs can effectively decrease ALP activity, resulting in the recovery of catalytic activity of PANI-MnO2. Therefore, sensitive and selective OPs detection is achieved. Under the optimal conditions, excellent detection performance in term of glyphosate as a model is achieved with a linear range from 0.50 to 50 μM, the detection limit is 0.39 μM (S/N = 3). The utility of method is further improved by combining a portable smartphone platform with a color picking application. The colorimetric platform achieves instrument-free detection of OPs and overcomes the uneven color distribution of traditional paper-based chip, providing an alternative strategy for the qualitative discernment and semi-quantitative analysis of OPs on-site.
Collapse
Affiliation(s)
- Cheng-Lin Yang
- State Key Laboratory of Food Science and Resources, School of Food Science and Technology, Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi 214122, China
| | - Li-Hong Yu
- State Key Laboratory of Food Science and Resources, School of Food Science and Technology, Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi 214122, China
| | - Yue-Hong Pang
- State Key Laboratory of Food Science and Resources, School of Food Science and Technology, Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China
| | - Xiao-Fang Shen
- State Key Laboratory of Food Science and Resources, School of Food Science and Technology, Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi 214122, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi 214122, China.
| |
Collapse
|
9
|
Chen GY, Chen LX, Gao J, Chen C, Guan J, Cao Z, Hu Y, Yang FQ. A Novel Molecularly Imprinted Sensor Based on CuO Nanoparticles with Peroxidase-like Activity for the Selective Determination of Astragaloside-IV. BIOSENSORS 2023; 13:959. [PMID: 37998134 PMCID: PMC10669883 DOI: 10.3390/bios13110959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 10/22/2023] [Accepted: 10/25/2023] [Indexed: 11/25/2023]
Abstract
In this work, dopamine (DA) was polymerized on the surface of CuO nanoparticles (CuO NPs) to form a molecularly imprinted polymer (MIP@PDA/CuO NPs) for the colorimetric detection of astragaloside-IV (AS-IV). The synthesis process of MIP is simple and easy to operate, without adding other monomers or initiators. CuO NPs has high peroxidase (POD)-like activity that can catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) to generate oxidized TMB (OxTMB) in the presence of H2O2, having a maximum ultraviolet-visible (UV-Vis) absorption peak at 652 nm. The AS-IV can specifically bind to the surface imprinted cavities and prevent the entry of TMB and H2O2, which will lead to the inhibition of the catalytic reaction. Therefore, a new approach based on the POD-like activity of MIP@PDA/CuO NPs for AS-IV detection was developed with a linear range from 0.000341 to 1.024 mg/mL. The LOD and LOQ are 0.000991 and 0.000341 mg/mL, respectively. The developed method can accurately determine AS-IV in Huangqi Granules and different batches of Ganweikang Tablets, which are similar to the results measured by HPLC-ELSD and meet the requirements of Chinese Pharmacopoeia (2020 edition) for the amount of AS-IV in Huangqi Granules. The combination of MIP with CuO NPs not only endows the detection of AS-IV with high selectivity and reliability, but also expands the application of nanozymes in the detection of small-molecule compounds that have weak UV absorption, and do not have reducibility or oxidation properties.
Collapse
Affiliation(s)
- Guo-Ying Chen
- Department of Pharmaceutical Engineering, School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China; (G.-Y.C.); (L.-X.C.)
| | - Ling-Xiao Chen
- Department of Pharmaceutical Engineering, School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China; (G.-Y.C.); (L.-X.C.)
| | - Jin Gao
- Jiaheng Pharmaceutical Technology Co., Ltd., Zhuhai 519000, China; (J.G.); (C.C.); (J.G.); (Z.C.)
| | - Chengyu Chen
- Jiaheng Pharmaceutical Technology Co., Ltd., Zhuhai 519000, China; (J.G.); (C.C.); (J.G.); (Z.C.)
| | - Jianli Guan
- Jiaheng Pharmaceutical Technology Co., Ltd., Zhuhai 519000, China; (J.G.); (C.C.); (J.G.); (Z.C.)
| | - Zhiming Cao
- Jiaheng Pharmaceutical Technology Co., Ltd., Zhuhai 519000, China; (J.G.); (C.C.); (J.G.); (Z.C.)
- Henan Fusen Pharmaceutical Co., Ltd., Nanyang 473000, China
| | - Yuanjia Hu
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macao 999078, China
| | - Feng-Qing Yang
- Department of Pharmaceutical Engineering, School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China; (G.-Y.C.); (L.-X.C.)
| |
Collapse
|
10
|
Nazim T, Lusina A, Cegłowski M. Recent Developments in the Detection of Organic Contaminants Using Molecularly Imprinted Polymers Combined with Various Analytical Techniques. Polymers (Basel) 2023; 15:3868. [PMID: 37835917 PMCID: PMC10574876 DOI: 10.3390/polym15193868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 09/13/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023] Open
Abstract
Molecularly imprinted polymers (MIPs) encompass a diverse array of polymeric matrices that exhibit the unique capacity to selectively identify a designated template molecule through specific chemical moieties. Thanks to their pivotal attributes, including exceptional selectivity, extended shelf stability, and other distinct characteristics, this class of compounds has garnered interest in the development of highly responsive sensor systems. As a result, the incorporation of MIPs in crafting distinctive sensors and analytical procedures tailored for specific analytes across various domains has increasingly become a common practice within contemporary analytical chemistry. Furthermore, the range of polymers amenable to MIP formulation significantly influences the potential utilization of both conventional and innovative analytical methodologies. This versatility expands the array of possibilities in which MIP-based sensing can be employed in recognition systems. The following review summarizes the notable progress achieved within the preceding seven-year period in employing MIP-based sensing techniques for analyte determination.
Collapse
Affiliation(s)
| | | | - Michał Cegłowski
- Faculty of Chemistry, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland; (T.N.); (A.L.)
| |
Collapse
|
11
|
Mazuryk J, Klepacka K, Kutner W, Sharma PS. Glyphosate Separating and Sensing for Precision Agriculture and Environmental Protection in the Era of Smart Materials. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023. [PMID: 37384557 DOI: 10.1021/acs.est.3c01269] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/01/2023]
Abstract
The present article critically and comprehensively reviews the most recent reports on smart sensors for determining glyphosate (GLP), an active agent of GLP-based herbicides (GBHs) traditionally used in agriculture over the past decades. Commercialized in 1974, GBHs have now reached 350 million hectares of crops in over 140 countries with an annual turnover of 11 billion USD worldwide. However, rolling exploitation of GLP and GBHs in the last decades has led to environmental pollution, animal intoxication, bacterial resistance, and sustained occupational exposure of the herbicide of farm and companies' workers. Intoxication with these herbicides dysregulates the microbiome-gut-brain axis, cholinergic neurotransmission, and endocrine system, causing paralytic ileus, hyperkalemia, oliguria, pulmonary edema, and cardiogenic shock. Precision agriculture, i.e., an (information technology)-enhanced approach to crop management, including a site-specific determination of agrochemicals, derives from the benefits of smart materials (SMs), data science, and nanosensors. Those typically feature fluorescent molecularly imprinted polymers or immunochemical aptamer artificial receptors integrated with electrochemical transducers. Fabricated as portable or wearable lab-on-chips, smartphones, and soft robotics and connected with SM-based devices that provide machine learning algorithms and online databases, they integrate, process, analyze, and interpret massive amounts of spatiotemporal data in a user-friendly and decision-making manner. Exploited for the ultrasensitive determination of toxins, including GLP, they will become practical tools in farmlands and point-of-care testing. Expectedly, smart sensors can be used for personalized diagnostics, real-time water, food, soil, and air quality monitoring, site-specific herbicide management, and crop control.
Collapse
Affiliation(s)
- Jarosław Mazuryk
- Department of Electrode Processes, Institute of Physical Chemistry, Polish Academy of Sciences, 01-224 Warsaw, Poland
- Bio & Soft Matter, Institute of Condensed Matter and Nanosciences, Université catholique de Louvain, 1 Place Louis Pasteur, 1348 Louvain-la-Neuve, Belgium
| | - Katarzyna Klepacka
- Functional Polymers Research Team, Institute of Physical Chemistry, Polish Academy of Sciences, 01-224 Warsaw, Poland
- ENSEMBLE3 sp. z o. o., 01-919 Warsaw, Poland
- Faculty of Mathematics and Natural Sciences. School of Sciences, Cardinal Stefan Wyszynski University in Warsaw, 01-938 Warsaw, Poland
| | - Włodzimierz Kutner
- Faculty of Mathematics and Natural Sciences. School of Sciences, Cardinal Stefan Wyszynski University in Warsaw, 01-938 Warsaw, Poland
- Modified Electrodes for Potential Application in Sensors and Cells Research Team, Institute of Physical Chemistry, Polish Academy of Sciences, 01-224 Warsaw, Poland
| | - Piyush Sindhu Sharma
- Functional Polymers Research Team, Institute of Physical Chemistry, Polish Academy of Sciences, 01-224 Warsaw, Poland
| |
Collapse
|
12
|
Sodkrathok P, Karuwan C, Kamsong W, Tuantranont A, Amatatongchai M. Patulin-imprinted origami 3D-ePAD based on graphene screen-printed electrode modified with Mn-ZnS quantum dot coated with a molecularly imprinted polymer. Talanta 2023; 262:124695. [PMID: 37229813 DOI: 10.1016/j.talanta.2023.124695] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 04/27/2023] [Accepted: 05/19/2023] [Indexed: 05/27/2023]
Abstract
We developed a novel, compact, three-dimensional electrochemical paper-based analytical device (3D-ePAD) for patulin (PT) determination. The selective and sensitive PT-imprinted Origami 3D-ePAD was constructed based on a graphene screen-printed electrode modified with manganese-zinc sulfide quantum dots coated with patulin imprinted polymer (Mn-ZnS QDs@PT-MIP/GSPE). The Mn-ZnS QDs@PT-MIP was synthesized using 2-oxindole as the template, methacrylic acid (MAA) as a monomer, N,N'-(1,2-dihydroxyethylene) bis (acrylamide) (DHEBA) as cross-linker and 2,2'-azobis (2-methylpropionitrile) (AIBN) as initiator, respectively. The Origami 3D-ePAD was designed with hydrophobic barrier layers formed on filter paper to provide three-dimensional circular reservoirs and assembled electrodes. The synthesized Mn-ZnS QDs@PT-MIP was quickly loaded on the electrode surface by mixing with graphene ink and then screen-printing on the paper. The PT-imprinted sensor provides the greatest enhancement in redox response and electrocatalytic activity, which we attributed to synergetic effects. This arose from an excellent electrocatalytic activity and good electrical conductivity of Mn-ZnS QDs@PT-MIP, which improved electron transfer between PT and the electrode surface. Under the optimized DPV conditions, a well-defined PT oxidation peak appears at +0.15 V (vs Ag/AgCl) using 0.1 M of phosphate buffer (pH 6.5) containing 5 mM K3Fe(CN)6 as the supporting electrolyte. Our developed PT imprinted Origami 3D-ePAD revealed excellent linear dynamic ranges of 0.001-25 μM, with a detection limit of 0.2 nM. Detection performance indicated that our Origami 3D-ePAD possesses outstanding detection performance from fruits and CRM in terms of high accuracy (%Error for inter-day is 1.11%) and precision (%RSD less than 4.1%). Therefore, the proposed method is well-suited as an alternative platform for ready-to-use sensors in food safety. The imprinted Origami 3D-ePAD is an excellent disposable device with a simple, cost-effective, and fast analysis, and it is ready to use for determining patulin in actual samples.
Collapse
Affiliation(s)
- Porntip Sodkrathok
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Chanpen Karuwan
- Graphene and Printed Electronics for Dual-Use Applications Research Division (GPERD), National Science and Technology Development Agency (NSTDA), Pathum Thani, 12120, Thailand
| | - Wichayaporn Kamsong
- Graphene and Printed Electronics for Dual-Use Applications Research Division (GPERD), National Science and Technology Development Agency (NSTDA), Pathum Thani, 12120, Thailand
| | - Adisorn Tuantranont
- Graphene and Printed Electronics for Dual-Use Applications Research Division (GPERD), National Science and Technology Development Agency (NSTDA), Pathum Thani, 12120, Thailand
| | - Maliwan Amatatongchai
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
| |
Collapse
|
13
|
Assi N, Rypar T, Macka M, Adam V, Vaculovicova M. Microfluidic paper-based fluorescence sensor for L-homocysteine using a molecularly imprinted polymer and in situ-formed fluorescent quantum dots. Talanta 2023; 255:124185. [PMID: 36634429 DOI: 10.1016/j.talanta.2022.124185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/29/2022] [Accepted: 12/07/2022] [Indexed: 01/07/2023]
Abstract
Microfluidic paper-based analytical devices modified with molecularly imprinted polymers (μPADs@MIPs) were developed for fluorescent detection of targeted thiols via in situ UV-induced formation of quantum dots (μPADs@MIPs@QDs). The selectivity enhancement by the MIP layer formed on the filter paper surface was demonstrated for the isolation of L-homocysteine from wine. Followed by the addition of metal precursors solution (Zn/Cd/Cu) and UV irradiation, fluorescent quantum dots were formed thus enabling quantitative detection of the thiol (serving as a QD capping agent). The effect of different semiconductors was investigated to achieve a lower band gap and higher fluorescence intensity. Increasing fluorescence intensity in the presence of thiol groups was obtained for the following precursors mixture composition: ZnCdCu/S > ZnCd/S > ZnCu/S > ZnS. The proposed method has a good relationship between the fluorescence intensity of ZnCdCu/S QDs and L-homocysteine in a linear range from 0.74 to 7.40 μM with a limit of detection (LOD) and quantification (LOQ) of 0.51 and 1.71 μM respectively. This method was applied for the determination of L-homocysteine in white wine with RSD under 6.37%.
Collapse
Affiliation(s)
- Navid Assi
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ 613 00, Brno, Czech Republic
| | - Tomas Rypar
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ 613 00, Brno, Czech Republic
| | - Mirek Macka
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic
| | - Vojtech Adam
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ 613 00, Brno, Czech Republic
| | - Marketa Vaculovicova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ 613 00, Brno, Czech Republic.
| |
Collapse
|
14
|
Wang M, Qiu J, Zhu C, Hua Y, Yu J, Jia L, Xu J, Li J, Li Q. A Fluorescent Molecularly Imprinted Polymer-Coated Paper Sensor for On-Site and Rapid Detection of Glyphosate. Molecules 2023; 28:molecules28052398. [PMID: 36903643 PMCID: PMC10004823 DOI: 10.3390/molecules28052398] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 02/22/2023] [Accepted: 02/27/2023] [Indexed: 03/08/2023] Open
Abstract
Due to the massive use and abuse of pesticides, practices which have led to serious threats to human health, the research community must develop on-site and rapid detection technology of pesticide residues to ensure food safety. Here, a paper-based fluorescent sensor, integrated with molecularly imprinted polymer (MIP) targeting glyphosate, was prepared by a surface-imprinting strategy. The MIP was synthesized by a catalyst-free imprinting polymerization technique and exhibited highly selective recognition capability for glyphosate. The MIP-coated paper sensor not only remained selective, but also displayed a limit of detection of 0.29 µmol and a linear detection range from 0.5 to 10 µmol. Moreover, the detection time only took about 5 min, which is beneficial for rapid detection of glyphosate in food samples. The detection accuracy of such paper sensor was good, with a spiked recovery rate of 92-117% in real samples. The fluorescent MIP-coated paper sensor not only has good specificity, which is helpful to reduce the food matrix interference and shorten the sample pretreatment time, but it also has the merits of high stability, low-cost and ease of operation and carrying, displaying great potential for application in the on-site and rapid detection of glyphosate for food safety.
Collapse
Affiliation(s)
- Meng Wang
- Jiangsu Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation Base, Ministry of Science and Technology, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Jun Qiu
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Chennuo Zhu
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Yunyan Hua
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Jie Yu
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Lulu Jia
- State Grid Jiangxi Electric Power Research Institute, Nanchang 330096, China
| | - Jianhong Xu
- Jiangsu Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation Base, Ministry of Science and Technology, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China
- Correspondence: (J.X.); (J.L.); (Q.L.)
| | - Jianlin Li
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
- Correspondence: (J.X.); (J.L.); (Q.L.)
| | - Qianjin Li
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
- Correspondence: (J.X.); (J.L.); (Q.L.)
| |
Collapse
|
15
|
Amatatongchai M, Thimoonnee S, Somnet K, Chairam S, Jarujamrus P, Nacapricha D, Lieberzeit PA. Origami 3D-microfluidic paper-based analytical device for detecting carbaryl using mesoporous silica-platinum nanoparticles with a molecularly imprinted polymer shell. Talanta 2023; 254:124202. [PMID: 36549139 DOI: 10.1016/j.talanta.2022.124202] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/14/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022]
Abstract
Herein, we present a novel Origami 3D-μPAD for colorimetric carbaryl detection using a super-efficient catalyst, namely mesoporous silica-platinum nanoparticles coated with a molecularly imprinted polymer (MSN-PtNPs@MIP). Morphological and structural characterization reveals that coating MIP on the MSN-PtNPs surface significantly increases the selective area, leading to larger numbers of imprinting sites for improved sensitivity and selectivity in determining carbaryl. The as-prepared MSN-PtNPs@MIP was used for catalytic oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H2O2. Carbaryl selectively binds to the cavities embedded on the MSN-PtNPs surface and subsequently inhibits TMB oxidation leading the color to change to light blue. The change of reaction color from dark blue to light blue depends on the concentration of carbaryl within the 3D-μPAD detection zone. This design integrates the advantages of highly efficient sample delivery through micro channels (top layer) and efficient partition/separation paths (bottom layer) of the cellulose substrate to achieve both improved detection sensitivity and selectivity. Assay on the Origami 3D-μPAD can determine carbaryl by ImageJ detection, over a dynamic range of 0.002-20.00 mg kg-1, with a very low limit of detection at 1.5 ng g-1. The developed 3D-μPAD exhibit high accuracy when applied to detect carbaryl in fruits, with satisfactory recoveries from 90.1% to 104.0% and relative differences from the reference HPLC values less than 5.0%. Furthermore, the fabricated Origami 3D-μPAD provides reliable durability and good reproducibility (3.19% RSD for fifteen devices).
Collapse
Affiliation(s)
- Maliwan Amatatongchai
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Thailand.
| | - Suphatsorn Thimoonnee
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Kanpitcha Somnet
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Sanoe Chairam
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Purim Jarujamrus
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Duangjai Nacapricha
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok, 10400, Thailand
| | - Peter A Lieberzeit
- University of Vienna, Faculty for Chemistry, Department of Physical Chemistry, 1090, Vienna, Austria
| |
Collapse
|
16
|
Wang S, Xu S, Zhou Q, Liu Z, Xu Z. State-of-the-art molecular imprinted colorimetric sensors and their on-site inspecting applications. J Sep Sci 2023:e2201059. [PMID: 36842066 DOI: 10.1002/jssc.202201059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/19/2023] [Accepted: 02/22/2023] [Indexed: 02/27/2023]
Abstract
Molecular imprinted colorimetric sensors can realize visual semi-quantitative analysis without the use of any equipment. With the advantages of low cost, fast response, ease of handling, and excellent recognition ability, the molecular imprinted colorimetric sensor shows great application potential in the field of sample rapid assay. Molecular imprinted colorimetric sensors can be prepared in various forms to meet the needs of different sample determination, such as film, hydrogel, strip, and adsorption coating. In this review, the preparation methods for various types of molecularly imprinted colorimetric sensors are systematically introduced. Their applications in the field of on-site biological sample detection, drug detection, disease treatment, chiral substance detection and separation, environmental analysis, and food safety detection are introduced. The limitations encountered in the practical application are presented, and the future development directions prospect.
Collapse
Affiliation(s)
- Sitao Wang
- Faculty of Science, Kunming University of Science and Technology, Kunming, P. R. China
| | - Shufang Xu
- Faculty of Science, Kunming University of Science and Technology, Kunming, P. R. China
| | - Qingqing Zhou
- Faculty of Science, Kunming University of Science and Technology, Kunming, P. R. China
| | - Zhimin Liu
- Faculty of Science, Kunming University of Science and Technology, Kunming, P. R. China
| | - Zhigang Xu
- Faculty of Science, Kunming University of Science and Technology, Kunming, P. R. China
| |
Collapse
|
17
|
Burnage SC, Bell J, Wan W, Kislenko E, Rurack K. Combining a hybrid chip and tube microfluidic system with fluorescent molecularly imprinted polymer (MIP) core-shell particles for the derivatisation, extraction, and detection of peptides with N-terminating phosphorylated tyrosine. LAB ON A CHIP 2023; 23:466-474. [PMID: 36655759 DOI: 10.1039/d2lc00955b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
The reliable identification and quantitation of phosphorylated amino acids, peptides and proteins is one of the key challenges in contemporary bioanalytical research, an area of particular interest when attempting to diagnose and treat diseases at an early stage. We have developed a synthetic probe for targeting phosphorylated amino acids, based on core-shell submicron-sized particles consisting of a silica core, coated with a molecularly imprinted polymer (MIP) shell. The MIP layer contains a fluorescent probe crosslinker which binds selectively to phosphorylated tyrosine (pY) moieties with a significant imprinting factor (IF) and responds with a "light-up" fluorescence signal. The bead-based ratiometric detection scheme has been successfully transferred to a microfluidic chip format and its applicability to rapid assays has been exemplarily shown by discriminating a pY-terminating oligopeptide against its non-phosphorylated counterpart. Such miniaturised devices could lead to an automated pY or pY N-terminated peptide measurement system in the future. The setup combines a modular microfluidic system for amino acid derivatisation, extraction (by micropillar co-flow) and selective adsorption and detection with the fluorescent MIP core-shell particle probes. A miniaturised optical assembly for low-light fluorescence measurements was also developed, based on miniaturised opto-electronic parts and optical fibres. The emission from the MIP particles upon binding of pY or pY N-terminated peptides could be monitored in real-time.
Collapse
Affiliation(s)
- Samual C Burnage
- Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489 Berlin, Germany.
| | - Jérémy Bell
- Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489 Berlin, Germany.
| | - Wei Wan
- Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489 Berlin, Germany.
| | - Evgeniia Kislenko
- Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489 Berlin, Germany.
| | - Knut Rurack
- Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489 Berlin, Germany.
| |
Collapse
|
18
|
Mazuryk J, Klepacka K, Piechowska J, Kalecki J, Derzsi L, Piotrowski P, Paszke P, Pawlak DA, Berneschi S, Kutner W, Sharma PS. In-Capillary Photodeposition of Glyphosate-Containing Polyacrylamide Nanometer-Thick Films. ACS APPLIED POLYMER MATERIALS 2023; 5:223-235. [PMID: 36660253 PMCID: PMC9841503 DOI: 10.1021/acsapm.2c01461] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 11/07/2022] [Indexed: 06/17/2023]
Abstract
The present research reports on in-water, site-specific photodeposition of glyphosate (GLP)-containing polyacrylamide (PAA-GLP) nanometer-thick films (nanofilms) on an inner surface of fused silica (fused quartz) microcapillaries presilanized with trimethoxy(octen-7-yl)silane (TMOS). TMOS was chosen because of the vinyl group presence in its structure, enabling its participation in the (UV light)-activated free-radical polymerization (UV-FRP) after its immobilization on a fused silica surface. The photodeposition was conducted in an aqueous (H2O/ACN; 3:1, v/v) solution, using UV-FRP (λ = 365 nm) of the acrylamide (AA) functional monomer, the N,N'-methylenebis(acrylamide) (BAA) cross-linking monomer, GLP, and the azobisisobutyronitrile (AIBN) UV-FRP initiator. Acetonitrile (ACN) was used as the porogen and the solvent to dissolve monomers and GLP. Because of the micrometric diameters of microcapillaries, the silanization and photodeposition procedures were first optimized on fused silica slides. The introduction of TMOS, as well as the formation of PAA and PAA-GLP nanofilms, was determined using atomic force microscopy (AFM), scanning electron microscopy with energy-dispersive X-ray (SEM-EDX) spectroscopy, and confocal micro-Raman spectroscopy. Particularly, AFM and SEM-EDX measurements determined nanofilms' thickness and GLP content, respectively, whereas in-depth confocal (micro-Raman spectroscopy)-assisted imaging of PAA- and PAA-GLP-coated microcapillary inner surfaces confirmed the successful photodeposition. Moreover, we examined the GLP impact on polymer gelation by monitoring hydration in a hydrogel and a dried powder PAA-GLP. Our study demonstrated the usefulness of the in-capillary micro-Raman spectroscopy imaging and in-depth profiling of GLP-encapsulated PAA nanofilms. In the future, our simple and inexpensive procedure will enable the fabrication of polymer-based microfluidic chemosensors or adsorptive-separating devices for GLP detection, determination, and degradation.
Collapse
Affiliation(s)
- Jaroslaw Mazuryk
- Electrode
Processes Research Team, Institute of Physical
Chemistry Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
- Bio
& Soft Matter, Institute of Condensed Matter and Nanosciences, Université catholique de Louvain, 1 Place Louis Pasteur, 1348 Louvain-la-Neuve, Belgium
| | - Katarzyna Klepacka
- Functional
Polymers Research Team, Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
- ENSEMBLE3
sp. z o. o., Wólczyńska
133, 01-919 Warsaw, Poland
| | - Joanna Piechowska
- Functional
Polymers Research Team, Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Jakub Kalecki
- Functional
Polymers Research Team, Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Ladislav Derzsi
- Microfluidics
and Complex Fluids Research Team, Institute
of Physical Chemistry Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Piotr Piotrowski
- Faculty
of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
- ENSEMBLE3
sp. z o. o., Wólczyńska
133, 01-919 Warsaw, Poland
| | - Piotr Paszke
- Faculty
of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
- ENSEMBLE3
sp. z o. o., Wólczyńska
133, 01-919 Warsaw, Poland
| | - Dorota A. Pawlak
- Faculty
of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
- ENSEMBLE3
sp. z o. o., Wólczyńska
133, 01-919 Warsaw, Poland
| | - Simone Berneschi
- Institute
of Applied Physics “Nello Carrara”—National Research
Council (IFAC-CNR), Via Madonna del Piano, 10, 50019 Sesto Fiorentino, FI, Italy
| | - Wlodzimierz Kutner
- Electrode
Processes Research Team, Institute of Physical
Chemistry Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
- Faculty
of Mathematics and Natural Sciences. School of Sciences, Cardinal Stefan Wyszynski University in Warsaw, Wóycickiego 1/3, 01-938 Warsaw, Poland
| | - Piyush Sindhu Sharma
- Functional
Polymers Research Team, Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| |
Collapse
|
19
|
Magnetic fluorescent probe of hydroxylated-halloysite and nitrogen-doped graphene quantum dots in molecularly imprinted polymer to enrich and determine marbofloxacin. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
20
|
Cheng Y, Li G, Huang X, Qian Z, Peng C. Label-Free Fluorescent Turn-On Glyphosate Sensing Based on DNA-Templated Silver Nanoclusters. BIOSENSORS 2022; 12:bios12100832. [PMID: 36290969 PMCID: PMC9599485 DOI: 10.3390/bios12100832] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 09/24/2022] [Accepted: 10/03/2022] [Indexed: 05/31/2023]
Abstract
In this work, a label-free fluorescent detection method for glyphosate, based on DNA-templated silver nanoclusters (DNA-Ag NCs) and a Cu2+-ion-modulated strategy, was developed. In the presence of Cu2+, the fluorescence of the DNA-Ag NCs was quenched. Glyphosate can restore the fluorescence of DNA-Ag NCs. By analyzing the storage stability of the obtained DNA-Ag NCs using different DNA templates, specific DNA-Ag NCs were selected for the construction of the glyphosate sensor. The ultrasensitive detection of glyphosate was achieved by optimizing the buffer pH and Cu2+ concentration. The sensing of glyphosate demonstrated a linear response in the range of 1.0-50 ng/mL. The limit of detection (LOD) was 0.2 ng/mL. The proposed method was successfully applied in the detection of glyphosate in a real sample, indicating its high application potential for glyphosate detection.
Collapse
Affiliation(s)
- Yuliang Cheng
- State Key Laboratory of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, China
- School of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, China
| | - Guowen Li
- State Key Laboratory of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, China
- School of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, China
| | - Xiufang Huang
- State Key Laboratory of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, China
- School of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, China
| | - Zhijuan Qian
- Nanjing Customs District Light Industry 375 Productsand Children’s Products Inspection Center, Yangzhou 225009, China
| | - Chifang Peng
- State Key Laboratory of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, China
- School of Food Science and Technology, Jiangnan University, Lihu Road 1800, Wuxi 214122, China
- International Joint Laboratory on Food Safety, Jiangnan University, Lihu Road 1800, Wuxi 214122, China
| |
Collapse
|
21
|
Shakeel A, Rizwan K, Farooq U, Iqbal S, Iqbal T, Awwad NS, Ibrahium HA. Polymer based nanocomposites: A strategic tool for detection of toxic pollutants in environmental matrices. CHEMOSPHERE 2022; 303:134923. [PMID: 35568211 DOI: 10.1016/j.chemosphere.2022.134923] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 04/11/2022] [Accepted: 05/07/2022] [Indexed: 06/15/2023]
Abstract
A large fraction of population is suffering from waterborne diseases due to the contaminated drinking water. Both anthropogenic and natural sources are responsible for water contamination. Revolution in industrial and agriculture sectors along with a huge increase in human population has brought more amount of wastes like heavy metals, pesticides and antibiotics. These toxins are very harmful for human health, therefore, it is necessary to sense their presence in environment. Conventional strategies face various problems in detection and quantification of these pollutants such as expensive equipment and requirement of high maintenance with limited portability. Recently, nanostructured devices have been developed to detect environmental pollutants. Polymeric nanocomposites have been found robust, cost effective, highly efficient and accurate for sensing various environmental pollutants and this is due to their porous framework, multi-functionalities, redox properties, great conductivity, catalytic features, facile operation at room temperature and large surface area. Synergistic effects between polymeric matrix and nanomaterials are responsible for improved sensing features and environmental adaptability. This review focuses on the recent advancement in polymeric nanocomposites for sensing heavy metals, pesticides and antibiotics. The advantages, disadvantages, operating conditions and future perspectives of polymeric nanocomposites for sensing toxic pollutants have also been discussed.
Collapse
Affiliation(s)
- Ahmad Shakeel
- Laboratory of Process Engineering, NeptunLab, Department of Microsystems Engineering (IMTEK), Albert Ludwig University of Freiburg, Freiburg, 79110, Germany; Freiburg Materials Research Center (FMF), Albert Ludwig University of Freiburg, Freiburg, 79104, Germany; Department of Chemical, Polymer & Composite Materials Engineering, University of Engineering & Technology, New Campus (KSK), Lahore, 54890, Pakistan; Faculty of Civil Engineering and Geosciences, Department of Hydraulic Engineering, Delft University of Technology, Stevinweg 1, 2628, CN, Delft, the Netherlands
| | - Komal Rizwan
- Department of Chemistry, University of Sahiwal, Sahiwal, 57000, Pakistan.
| | - Ujala Farooq
- Faculty of Aerospace Engineering, Department of Aerospace Structures and Materials, Delft University of Technology, Kluyverweg 1, 2629, HS, Delft, the Netherlands.
| | - Shahid Iqbal
- Department of Chemistry, School of Natural Sciences (SNS), National University of Sciences and Technology (NUST), H-12, Islamabad, 46000, Pakistan
| | - Tanveer Iqbal
- Department of Chemical, Polymer & Composite Materials Engineering, University of Engineering & Technology, New Campus (KSK), Lahore, 54890, Pakistan
| | - Nasser S Awwad
- Chemistry Department, Faculty of Science, King Khalid University, P.O. Box 9004, Abha, 61413, Saudi Arabia
| | - Hala A Ibrahium
- Biology Department, Faculty of Science, King Khalid University, P.O. Box 9004, Abha, 61413, Saudi Arabia; Department of Semi Pilot Plant, Nuclear Materials Authority, P.O. Box 530, El Maadi, Egypt
| |
Collapse
|
22
|
Kimani M, Kislenko E, Gawlitza K, Rurack K. Fluorescent molecularly imprinted polymer particles for glyphosate detection using phase transfer agents. Sci Rep 2022; 12:14151. [PMID: 35986032 PMCID: PMC9391380 DOI: 10.1038/s41598-022-16825-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 07/18/2022] [Indexed: 01/19/2023] Open
Abstract
In this work, molecular imprinting was combined with direct fluorescence detection of the pesticide Glyphosate (GPS). Firstly, the solubility of highly polar GPS in organic solvents was improved by using lipophilic tetrabutylammonium (TBA+) and tetrahexylammonium (THA+) counterions. Secondly, to achieve fluorescence detection, a fluorescent crosslinker containing urea-binding motifs was used as a probe for GPS-TBA and GPS-THA salts in chloroform, generating stable complexes through hydrogen bond formation. The GPS/fluorescent dye complexes were imprinted into 2-3 nm fluorescent molecularly imprinted polymer (MIP) shells on the surface of sub-micron silica particles using chloroform as porogen. Thus, the MIP binding behavior could be easily evaluated by fluorescence titrations in suspension to monitor the spectral changes upon addition of the GPS analytes. While MIPs prepared with GPS-TBA and GPS-THA both displayed satisfactory imprinting following titration with the corresponding analytes in chloroform, GPS-THA MIPs displayed better selectivity against competing molecules. Moreover, the THA+ counterion was found to be a more powerful phase transfer agent than TBA+ in a biphasic assay, enabling the direct fluorescence detection and quantification of GPS in water. A limit of detection of 1.45 µM and a linear range of 5-55 µM were obtained, which match well with WHO guidelines for the acceptable daily intake of GPS in water (5.32 µM).
Collapse
Affiliation(s)
- Martha Kimani
- grid.71566.330000 0004 0603 5458Chemical and Optical Sensing Division (1.9), Bundesanstalt für Materialforschung und -prüfung (BAM), 12200 Berlin, Germany
| | - Evgeniia Kislenko
- grid.71566.330000 0004 0603 5458Chemical and Optical Sensing Division (1.9), Bundesanstalt für Materialforschung und -prüfung (BAM), 12200 Berlin, Germany
| | - Kornelia Gawlitza
- grid.71566.330000 0004 0603 5458Chemical and Optical Sensing Division (1.9), Bundesanstalt für Materialforschung und -prüfung (BAM), 12200 Berlin, Germany
| | - Knut Rurack
- grid.71566.330000 0004 0603 5458Chemical and Optical Sensing Division (1.9), Bundesanstalt für Materialforschung und -prüfung (BAM), 12200 Berlin, Germany
| |
Collapse
|
23
|
Balciunas D, Plausinaitis D, Ratautaite V, Ramanaviciene A, Ramanavicius A. Towards electrochemical surface plasmon resonance sensor based on the molecularly imprinted polypyrrole for glyphosate sensing. Talanta 2022; 241:123252. [PMID: 35121544 DOI: 10.1016/j.talanta.2022.123252] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2021] [Revised: 12/24/2021] [Accepted: 01/19/2022] [Indexed: 12/16/2022]
Abstract
In this research the molecular imprinting technology was applied for the formation of glyphosate-sensitive layer. The glyphosate imprinted conducting polymer polypyrrole (MIPpy) was deposited on a gold chip/electrode and used as an electrochemical surface plasmon resonance (ESPR) sensor. The results described in this study disclose some restrictions and challenges, which arise during the development of glyphosate ESPR sensor based on the molecularly imprinted polymer development stage. It was demonstrated, that glyphosate could significantly affect the electrochemical deposition process of molecularly imprinted polymer on the electrode. The results of cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and surface plasmon resonance (SPR) have demonstrated that glyphosate molecules tend to interact with bare gold electrode and thus hinder the polypyrrole deposition. As a possible solution, the formation of a self-assembled monolayer (SAM) of 11-(1H-Pyrrol-1-yl)undecane-1-thiol (PUT) before electrochemical deposition of MIPpy and NIPpy was applied. Dissociation constant (KD) and free energy of Gibbs (ΔG0) values of glyphosate on MIPpy and Ppy without glyphosate imprints (NIPpy) were calculated. For the interaction of glyphosate with MIPpy the KD was determined as 38.18 ± 2.33⋅10-5 and ΔG0 as -19.51 ± 0.15 kJ/mol.
Collapse
Affiliation(s)
- Domas Balciunas
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT, 03225, Vilnius, Lithuania
| | - Deivis Plausinaitis
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT, 03225, Vilnius, Lithuania
| | - Vilma Ratautaite
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT, 03225, Vilnius, Lithuania; Nanotechnology Laboratory, Department of Functional Materials and Electronics, Center for Physical Sciences and Technology (FTMC), Saulėtekio av. 3, LT, 10257, Vilnius, Lithuania
| | - Almira Ramanaviciene
- NanoTechnas - Center for Nanotechnology and Material Science, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT, 03225, Vilnius, Lithuania
| | - Arunas Ramanavicius
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT, 03225, Vilnius, Lithuania; Nanotechnology Laboratory, Department of Functional Materials and Electronics, Center for Physical Sciences and Technology (FTMC), Saulėtekio av. 3, LT, 10257, Vilnius, Lithuania.
| |
Collapse
|
24
|
Red-Emitting Polymerizable Guanidinium Dyes as Fluorescent Probes in Molecularly Imprinted Polymers for Glyphosate Detection. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10030099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
The development of methodologies to sense glyphosate has gained momentum due to its toxicological and ecotoxicological effects. In this work, a red-emitting and polymerizable guanidinium benzoxadiazole probe was developed for the fluorescence detection of glyphosate. The interaction of the fluorescent probe and the tetrabutylammonium salt of glyphosate was studied via UV/vis absorption and fluorescence spectroscopy in chloroform and acetonitrile. The selective recognition of glyphosate was achieved by preparing molecularly imprinted polymers, able to discriminate against other common herbicides such as 2,4-dichlorophenoxyacetic acid (2,4-D) and 3,6-dichloro-2-methoxybenzoic acid (dicamba), as thin layers on submicron silica particles. The limits of detection of 4.8 µM and 0.6 µM were obtained for the sensing of glyphosate in chloroform and acetonitrile, respectively. The reported system shows promise for future application in the sensing of glyphosate through further optimization of the dye and the implementation of a biphasic assay with water/organic solvent mixtures for sensing in aqueous environmental samples.
Collapse
|
25
|
Thimoonnee S, Somnet K, Ngaosri P, Chairam S, Karuwan C, Kamsong W, Tuantranont A, Amatatongchai M. Fast, sensitive and selective simultaneous determination of paraquat and glyphosate herbicides in water samples using a compact electrochemical sensor. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:820-833. [PMID: 35142761 DOI: 10.1039/d1ay02201f] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
We report a new ready-to-use sensor for simultaneous determination of paraquat (PQ) and glyphosate (GLY) based on a graphite screen-printed electrode modified with a dual-molecularly imprinted polymer coated on a mesoporous silica-platinum core. Amino-mesoporous silica nanoparticles (MSN-NH2) were first synthesized by a simple co-condensation method using tetraethyl orthosilicate and 3-aminopropyltrimethoxysilane. PtNPs were then decorated on the surface of MSN-NH2 by chemical reduction. Finally, the dual-MIP was successfully coated on the MSN-PtNP core. This 3D-surface-imprinting strategy enhances the conductivity and monodispersity of the MSN-PtNPs@d-MIP. Quantitative analysis was performed by differential pulse voltammetry with an oxidation current appearing at -0.95 V for PQ and +0.97 V for GLY. The dual-MIP sensor shows good linear calibration curves in the range of 0.025-500 μM for both analytes with detection limits of 3.1 nM and 4.0 nM for PQ and GLY, respectively. The dual-MIP sensor shows high selectivity and specificity, attributed to the increased affinity of the imprinted cavities formed on the polymer film for the target PQ and GLY molecules. The proposed dual-MIP sensor was successfully applied to detect PQ and GLY concentrations simultaneously in water samples. The ready-to-use dual-MIP sensor is well suited for water-quality control and on-site applications without sophisticated instrumentation.
Collapse
Affiliation(s)
- Suphatsorn Thimoonnee
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand.
| | - Kanpitcha Somnet
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand.
| | - Pattanun Ngaosri
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand.
| | - Sanoe Chairam
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand.
| | - Chanpen Karuwan
- Graphene Sensor Laboratory (GPL), Graphene and Printed Electronics for Dual-Use Applications Research Division (GPERD), National Security and Dual-Use Technology Center (NSD), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Wichayaporn Kamsong
- Graphene Sensor Laboratory (GPL), Graphene and Printed Electronics for Dual-Use Applications Research Division (GPERD), National Security and Dual-Use Technology Center (NSD), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Adisorn Tuantranont
- Graphene Sensor Laboratory (GPL), Graphene and Printed Electronics for Dual-Use Applications Research Division (GPERD), National Security and Dual-Use Technology Center (NSD), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Maliwan Amatatongchai
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand.
| |
Collapse
|
26
|
Nontawong N, Ngaosri P, Chunta S, Jarujamrus P, Nacapricha D, Lieberzeit PA, Amatatongchai M. Smart sensor for assessment of oxidative/nitrative stress biomarkers using a dual-imprinted electrochemical paper-based analytical device. Anal Chim Acta 2022; 1191:339363. [PMID: 35033235 DOI: 10.1016/j.aca.2021.339363] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 12/06/2021] [Accepted: 12/06/2021] [Indexed: 12/15/2022]
Abstract
We present a novel dual-imprinted electrochemical paper-based analytical device (Di-ePAD) to simultaneously determine 8-hydroxy-2'-deoxyguanosine (8-OHdG) and 3-nitrotyrosine (3-NT) and assess oxidative and nitrative biomarkers in urine and plasma samples. The Di-ePAD was designed with hydrophobic barrier layers formed on filter paper to provide three-dimensional circular reservoirs and assembled electrodes. The molecularly imprinted polymer (MIP) was synthesized using a silica nanosphere decorated with silver nanoparticles (SiO2@AgNPs) as a core covered with dual-analyte imprinted sites on the polymer to recognize selectively and bind the target biomarkers. This strategy drives monodispersity and enhances the conductivity of the resulting MIP core-shell products. 3-NT-MIP and 8-OHdG-MIP were synthesized by successively coating the surface of SiO2@AgNPs with l-Cysteine via the thiol group, then terminating with MIP shells. The dual imprinted core-shell composites possess attractive properties for the target biomarkers' sensing, including catalytic activity, selectivity, and good conductivity. The Di-ePAD revealed excellent linear dynamic ranges of 0.01-500 μM for 3-NT and 0.05-500 μM for 8-OHdG, with detection limits of 0.0027 μM for 3-NT and 0.0138 μM for 8-OHdG. This newly developed method based on the synergistic effects of SiO2@AgNPs combined with promising properties of MIP offers outstanding selectivity, sensitivity, reproducibility, simplicity, and low cost for quantitative analysis of 3-NT and 8-OHdG. The proposed Di-ePAD showed good accuracy and precision when applied to actual samples, including urine and serum samples validated by a conventional HPLC method.
Collapse
Affiliation(s)
- Nongyao Nontawong
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Pattanun Ngaosri
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Suticha Chunta
- Faculty of Medical Technology, Prince of Songkla University, Songkhla, 90110, Thailand
| | - Purim Jarujamrus
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand
| | - Duangjai Nacapricha
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok, 10400, Thailand
| | - Peter A Lieberzeit
- University of Vienna, Faculty for Chemistry, Department of Physical Chemistry, 1090, Vienna, Austria
| | - Maliwan Amatatongchai
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand; Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Thailand.
| |
Collapse
|
27
|
Pang R, Zhu Q, Wei J, Meng X, Wang Z. Enhancement of the Detection Performance of Paper-Based Analytical Devices by Nanomaterials. Molecules 2022; 27:508. [PMID: 35056823 PMCID: PMC8779822 DOI: 10.3390/molecules27020508] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Revised: 12/29/2021] [Accepted: 01/10/2022] [Indexed: 12/01/2022] Open
Abstract
Paper-based analytical devices (PADs), including lateral flow assays (LFAs), dipstick assays and microfluidic PADs (μPADs), have a great impact on the healthcare realm and environmental monitoring. This is especially evident in developing countries because PADs-based point-of-care testing (POCT) enables to rapidly determine various (bio)chemical analytes in a miniaturized, cost-effective and user-friendly manner. Low sensitivity and poor specificity are the main bottlenecks associated with PADs, which limit the entry of PADs into the real-life applications. The application of nanomaterials in PADs is showing great improvement in their detection performance in terms of sensitivity, selectivity and accuracy since the nanomaterials have unique physicochemical properties. In this review, the research progress on the nanomaterial-based PADs is summarized by highlighting representative recent publications. We mainly focus on the detection principles, the sensing mechanisms of how they work and applications in disease diagnosis, environmental monitoring and food safety management. In addition, the limitations and challenges associated with the development of nanomaterial-based PADs are discussed, and further directions in this research field are proposed.
Collapse
Affiliation(s)
- Renzhu Pang
- Department of Thyroid Surgery, The First Hospital of Jilin University, Changchun 130021, China; (R.P.); (J.W.)
| | - Qunyan Zhu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China;
| | - Jia Wei
- Department of Thyroid Surgery, The First Hospital of Jilin University, Changchun 130021, China; (R.P.); (J.W.)
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China;
| | - Xianying Meng
- Department of Thyroid Surgery, The First Hospital of Jilin University, Changchun 130021, China; (R.P.); (J.W.)
| | - Zhenxin Wang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China;
- School of Applied Chemical Engineering, University of Science and Technology of China, Hefei 230026, China
| |
Collapse
|
28
|
Gu Y, Gao T, Zhang F, Lu C, Cao W, Fu Z, Hu C, Lyu L. Surface sulfur vacancies enhanced electron transfer over Co-ZnS quantum dots for efficient degradation of plasticizer micropollutants by peroxymonosulfate activation. CHINESE CHEM LETT 2021. [DOI: 10.1016/j.cclet.2021.12.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
29
|
Mamipour Z, Nematollahzadeh A, Kompany-Zareh M. Molecularly imprinted polymer grafted on paper and flat sheet for selective sensing and diagnosis: a review. Mikrochim Acta 2021; 188:279. [PMID: 34331135 DOI: 10.1007/s00604-021-04930-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 07/05/2021] [Indexed: 12/14/2022]
Abstract
Molecularly imprinted polymers are efficient and selective adsorbents which act as artificial receptors for desired compounds with the ability to recognize the size, shape, and functional groups of the compounds simultaneously. A molecularly imprinted polymer is prepared by the polymerization of functional monomers around a template (analyte) molecule. Afterward, the removal of the template from the polymer matrix leaves a selective cavity behind. The fabrication and development of molecularly imprinted polymers grew rapidly, due to their low cost, simple preparation, selectivity, sensitivity, and stable physicochemical properties. Traditionally, molecularly imprinted polymers can be synthesized using two main methods, namely bulk and surface imprinting. For more efficient use of the latter method, researchers have developed molecularly imprinted polymers grafted on the solid-phase matrix (substrate). This grafting technique would be particularly useful for surface imprinting of macromolecules, such as proteins. Cellulose fibers of papers with unique properties such as being abundant, retaining a porous structure, having good adsorption properties, and possessing hydroxyl groups naturally have gained much attention as substrate. The goal of this review is to introduce molecularly imprinted polymer-grafted or molecularly imprinted polymer-coated paper, as an interesting, simple, and efficient method in the detection and separation of small and large molecules. Therefore, in the present paper, several recent preparation techniques and applications of molecularly imprinted polymer-grafted paper are reviewed and discussed in detail. Green, cost-effective, selective, and sensitive paper-based sensor prepared via grafting molecularly imprinted polymer on paper surface with the potential use for online detection trace of analytes in the point-of-care testing.
Collapse
Affiliation(s)
- Zahra Mamipour
- Department of Chemistry, Institute of Advanced Studies in Basic Sciences, Zanjan, Iran.,Chemical Engineering Department, University of Mohaghegh Ardabili, P.O. Box 179, Ardabil, Iran
| | - Ali Nematollahzadeh
- Chemical Engineering Department, University of Mohaghegh Ardabili, P.O. Box 179, Ardabil, Iran.
| | - Mohsen Kompany-Zareh
- Department of Chemistry, Institute of Advanced Studies in Basic Sciences, Zanjan, Iran. .,Department of Chemistry, Dalhousie University, PO Box 15000, Halifax, NS, B3H 4R2, Canada.
| |
Collapse
|
30
|
Alahmad W, Varanusupakul P, Varanusupakul P. Recent Developments and Applications of Microfluidic Paper-Based Analytical Devices for the Detection of Biological and Chemical Hazards in Foods: A Critical Review. Crit Rev Anal Chem 2021; 53:233-252. [PMID: 34304654 DOI: 10.1080/10408347.2021.1949695] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Nowadays, food safety has become a major concern for the sustainability of global public health. Through the production and distribution steps, food can be contaminated by either chemical hazards or pathogens, and the determination of these plays a critical role in the processes of ensuring food safety. Therefore, the development of analytical tools that can provide rapid screening of these hazards is highly necessary. Microfluidic paper-based analytical devices (µPADs) have advanced significantly in recent years as they are rapid and low-cost analytical screening tools for testing contaminated food products. This review focuses on recent developments of µPADs for various applications in the food safety field. A description of the fabrication of selected papers is briefly discussed, and evaluation of the μPADs' performance with regard to their precision and accuracy as well as their limits of detection is critically assessed. The advantages and disadvantages of these devices are highlighted.
Collapse
Affiliation(s)
- Waleed Alahmad
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
| | | | - Pakorn Varanusupakul
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
31
|
Díaz-Álvarez M, Martín-Esteban A. Molecularly Imprinted Polymer-Quantum Dot Materials in Optical Sensors: An Overview of Their Synthesis and Applications. BIOSENSORS 2021; 11:bios11030079. [PMID: 33805669 PMCID: PMC7999655 DOI: 10.3390/bios11030079] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 03/10/2021] [Accepted: 03/11/2021] [Indexed: 05/03/2023]
Abstract
In the last decades analytical methods have focused on the determination of target analytes at very low concentration levels. This has been accomplished through the use of traditional analytical methods that usually require high reagent consumption, expensive equipment and long pretreatment steps. Thus, there is a demand for simple, rapid, highly selective and user-friendly detection procedures. Quantum dots (QDs) are semiconductor fluorescent nanomaterials with unique optoelectronic properties that have shown great potential for the development of fluorescence probes. Besides, the combination of QDs with molecularly imprinted polymer (MIPs), synthetic materials with selective recognition, have been proposed as useful materials in the development of optical sensors. The resulting MIP-QDs optical sensors integrate the advantages of both techniques: the high sensitivity of QDs-based fluorescence sensors and the high selectivity of MIPs. This review gives a brief overview of the strategies for the synthesis of MIPs-QDs based optical sensors, highlighting the modifications in the synthesis procedure that improve the sensor performance. Finally, a revision of recent applications in sensing and bioimaging is presented.
Collapse
|
32
|
Kazemifard N, Ensafi AA, Dehkordi ZS. A review of the incorporation of QDs and imprinting technology in optical sensors – imprinting methods and sensing responses. NEW J CHEM 2021. [DOI: 10.1039/d1nj01104a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
This review aims to cover the simultaneous method of using molecularly imprinted technology and quantum dots (QDs) as well as its application in the field of optical sensors.
Collapse
Affiliation(s)
- Nafiseh Kazemifard
- Department of Chemistry
- Isfahan University of Technology
- Isfahan 84156-83111
- Iran
| | - Ali A. Ensafi
- Department of Chemistry
- Isfahan University of Technology
- Isfahan 84156-83111
- Iran
| | | |
Collapse
|