1
|
Wouterlood FG. Techniques to Render Dendritic Spines Visible in the Microscope. ADVANCES IN NEUROBIOLOGY 2023; 34:69-102. [PMID: 37962794 DOI: 10.1007/978-3-031-36159-3_2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2023]
Abstract
A tiny detail visible on certain neurons at the limit of resolution in light microscopy went in 130 years of neuroscience research through a dazzling career from suspicious staining artifact to what we recognize today as a complex postsynaptic molecular machine: the dendritic spine.This chapter deals with techniques to make spines visible. The original technique, Golgi silver staining, is still being used today. Electron microscopy and automated field ion beam scanning electron microscopy are ultrahigh resolution techniques, albeit specialized. Other methods are intracellular injection, uptake of dyes, and recently the exploitation of genetically modified animals in which certain neurons express fluorescent protein in all their processes, including the nooks and crannies of their dendritic spines.
Collapse
Affiliation(s)
- Floris G Wouterlood
- Department of Anatomy & Neurosciences, Amsterdam UMC, Amsterdam, The Netherlands
| |
Collapse
|
2
|
Using a Hand-Held Gene Gun for Genetic Transformation of Tetrahymena thermophila. Methods Mol Biol 2021. [PMID: 34542863 DOI: 10.1007/978-1-0716-1661-1_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
Biolistic bombardment is widely used as a means of delivering vector-coated microparticles into microorganisms, cultured cells, and tissues. The first particle delivery system contained a helium propulsion unit (the gun) mounted in a vacuum-controlled chamber. In contrast, the hand-held gene gun does not operate within a chamber. It is completely hand-held, easy, and efficient to use, and it requires minimal space on the laboratory bench top. This chapter describes protocols for using a hand-held gene gun to deliver transformation vectors for overexpression of genes or gene replacement into the macronucleus of Tetrahymena thermophila. The protocols provide helpful information for preparing Tetrahymena for biolistic bombardment, preparation of vector-coated microcarriers, and basic gene gun operating procedures.
Collapse
|
3
|
Stewart MP, Langer R, Jensen KF. Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts. Chem Rev 2018; 118:7409-7531. [PMID: 30052023 PMCID: PMC6763210 DOI: 10.1021/acs.chemrev.7b00678] [Citation(s) in RCA: 456] [Impact Index Per Article: 65.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Intracellular delivery is a key step in biological research and has enabled decades of biomedical discoveries. It is also becoming increasingly important in industrial and medical applications ranging from biomanufacture to cell-based therapies. Here, we review techniques for membrane disruption-based intracellular delivery from 1911 until the present. These methods achieve rapid, direct, and universal delivery of almost any cargo molecule or material that can be dispersed in solution. We start by covering the motivations for intracellular delivery and the challenges associated with the different cargo types-small molecules, proteins/peptides, nucleic acids, synthetic nanomaterials, and large cargo. The review then presents a broad comparison of delivery strategies followed by an analysis of membrane disruption mechanisms and the biology of the cell response. We cover mechanical, electrical, thermal, optical, and chemical strategies of membrane disruption with a particular emphasis on their applications and challenges to implementation. Throughout, we highlight specific mechanisms of membrane disruption and suggest areas in need of further experimentation. We hope the concepts discussed in our review inspire scientists and engineers with further ideas to improve intracellular delivery.
Collapse
Affiliation(s)
- Martin P. Stewart
- Department of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, USA
- The Koch Institute for Integrative Cancer Research,
Massachusetts Institute of Technology, Cambridge, USA
| | - Robert Langer
- Department of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, USA
- The Koch Institute for Integrative Cancer Research,
Massachusetts Institute of Technology, Cambridge, USA
| | - Klavs F. Jensen
- Department of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, USA
| |
Collapse
|
4
|
Unraveling Individual Differences In The HIV-1 Transgenic Rat: Therapeutic Efficacy Of Methylphenidate. Sci Rep 2018; 8:136. [PMID: 29317696 PMCID: PMC5760575 DOI: 10.1038/s41598-017-18300-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Accepted: 12/07/2017] [Indexed: 01/12/2023] Open
Abstract
Despite the heterogeneity of HIV-1 associated neurocognitive disorders (HAND), assignment of categorical diagnoses based on the level of impairment (e.g., Frascati criteria) obfuscates the well-acknowledged variability observed within the population of HIV-1+ individuals. The present study sought to elucidate the natural heterogeneity in adult HIV-1 transgenic (Tg) rats using three interrelated aims. First, heterogeneity of the HIV-1 transgene was examined using a pretest-posttest design to assess therapeutic efficacy of oral self-administration (OSA) of methylphenidate (MPH; 2.4 ± 0.2 mg/kg), targeting neurotransmitter alterations in HIV-1, on temporal processing. Approximately 42% of HIV-1 Tg animals displayed an improvement in temporal processing following OSA of MPH. Second, repeated OSA of MPH (22–27 days) altered dendritic spine morphology in layer II-III pyramidal neurons in the medial prefrontal cortex. HIV-1 Tg animals exhibited a population shift towards longer spines with decreased head diameter on lower order branches; a shift associated with temporal processing impairment. Third, in HIV-1 Tg animals, dendritic spine backbone length (µm) was associated with temporal processing impairment; a brain/behavior relationship not observed in control animals. Assessing the therapeutic efficacy of MPH revealed heterogeneity in the neural mechanisms underlying neurocognitive impairments, providing a key target for individualized therapeutic and diagnostic approaches for HAND.
Collapse
|
5
|
Pirmoradi FN, Pattekar AV, Linn F, Recht MI, Volkel AR, Wang Q, Anderson GB, Veiseh M, Kjono S, Peeters E, Uhland SA, Chow EM. A microarray MEMS device for biolistic delivery of vaccine and drug powders. Hum Vaccin Immunother 2016; 11:1936-44. [PMID: 26090875 PMCID: PMC4635881 DOI: 10.1080/21645515.2015.1029211] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
We report a biolistic technology platform for physical delivery of particle formulations of drugs or vaccines using parallel arrays of microchannels, which generate highly collimated jets of particles with high spatial resolution. Our approach allows for effective delivery of therapeutics sequentially or concurrently (in mixture) at a specified target location or treatment area. We show this new platform enables the delivery of a broad range of particles with various densities and sizes into both in vitro and ex vivo skin models. Penetration depths of ∼1 mm have been achieved following a single ejection of 200 µg high-density gold particles, as well as 13.6 µg low-density polystyrene-based particles into gelatin-based skin simulants at 70 psi inlet gas pressure. Ejection of multiple shots at one treatment site enabled deeper penetration of ∼3 mm in vitro, and delivery of a higher dose of 1 mg gold particles at similar inlet gas pressure. We demonstrate that particle penetration depths can be optimized in vitro by adjusting the inlet pressure of the carrier gas, and dosing is controlled by drug reservoirs that hold precise quantities of the payload, which can be ejected continuously or in pulses. Future investigations include comparison between continuous versus pulsatile payload deliveries. We have successfully delivered plasmid DNA (pDNA)-coated gold particles (1.15 µm diameter) into ex vivo murine and porcine skin at low inlet pressures of ∼30 psi. Integrity analysis of these pDNA-coated gold particles confirmed the preservation of full-length pDNA after each particle preparation and jetting procedures. This technology platform provides distinct capabilities to effectively deliver a broad range of particle formulations into skin with specially designed high-speed microarray ejector nozzles.
Collapse
|
6
|
Gotesman M, Williams SA. Using a Handheld Gene Gun for Genetic Transformation of Tetrahymena thermophila. Methods Mol Biol 2016; 1365:373-383. [PMID: 26498798 DOI: 10.1007/978-1-4939-3124-8_22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This chapter describes protocols for using a handheld gene gun to deliver transformation vectors for overexpression of genes or gene replacement in the macronucleus of Tetrahymena thermophila. The protocols provide helpful information for preparing Tetrahymena for biolistic bombardment, preparation of vector-coated microcarriers, and basic gene gun operating procedures.
Collapse
Affiliation(s)
- Michael Gotesman
- Department of Biology, Technion - Israel Institute of Technology, Technion, Haifa, 3200003, Israel.
| | | |
Collapse
|
7
|
Saleem M, Lee KH. Synthesis, Characterization and Photophysical Properties of Novel Azole Derivatives. J Fluoresc 2015; 25:217-26. [DOI: 10.1007/s10895-015-1505-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2014] [Accepted: 01/02/2015] [Indexed: 10/24/2022]
|
8
|
Arsenault J, Nagy A, Henderson JT, O'Brien JA. Regioselective biolistic targeting in organotypic brain slices using a modified gene gun. J Vis Exp 2014:e52148. [PMID: 25407047 PMCID: PMC4249736 DOI: 10.3791/52148] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Transfection of DNA has been invaluable for biological sciences and with recent advances to organotypic brain slice preparations, the effect of various heterologous genes could thus be investigated easily while maintaining many aspects of in vivo biology. There has been increasing interest to transfect terminally differentiated neurons for which conventional transfection methods have been fraught with difficulties such as low yields and significant losses in viability. Biolistic transfection can circumvent many of these difficulties yet only recently has this technique been modified so that it is amenable for use in mammalian tissues. New modifications to the accelerator chamber have enhanced the gene gun's firing accuracy and increased its depths of penetration while also allowing the use of lower gas pressure (50 psi) without loss of transfection efficiency as well as permitting a focused regioselective spread of the particles to within 3 mm. In addition, this technique is straight forward and faster to perform than tedious microinjections. Both transient and stable expression are possible with nanoparticle bombardment where episomal expression can be detected within 24 hr and the cell survival was shown to be better than, or at least equal to, conventional methods. This technique has however one crucial advantage: it permits the transfection to be localized within a single restrained radius thus enabling the user to anatomically isolate the heterologous gene's effects. Here we present an in-depth protocol to prepare viable adult organotypic slices and submit them to regioselective transfection using an improved gene gun.
Collapse
Affiliation(s)
- Jason Arsenault
- Leslie Dan Faculty of Pharmacy, University of Toronto; MRC-Laboratory of Molecular Biology, Cambridge, UK
| | - Andras Nagy
- Leslie Dan Faculty of Pharmacy, University of Toronto
| | | | | |
Collapse
|
9
|
Martin-Ortigosa S, Wang K. Proteolistics: a biolistic method for intracellular delivery of proteins. Transgenic Res 2014; 23:743-56. [PMID: 25092532 DOI: 10.1007/s11248-014-9807-y] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2014] [Accepted: 05/29/2014] [Indexed: 11/26/2022]
Abstract
In this work, an intracellular protein delivery methodology termed "proteolistics" is described. This method utilizes a biolistic gun apparatus and involves a simple protein/projectile preparation step. The protein to be delivered is mixed with a gold particle microprojectile suspension and is placed onto a gene gun cartridge, where it is dehydrated using either lyophilization or room-temperature air-drying. Subsequent intracellular protein delivery is achieved in plant and mammalian tissues upon bombardment. Because the method does not require modification of delivery agents or cargo biomolecules and involves a simple physical deposition of the protein onto the microprojectiles, there is no restriction on protein type in terms of molecular weight, isoelectric point or tertiary structure. Because the method delivers protein through the widely used gene gun system, it can be readily applied to any tissue or organism amenable to biolistics. A variety of proteins with molecular weight ranging from 24 to 68 kDa and isoelectric point from 4.8 to 10.1 were tested in this work. It is anticipated that this simple and versatile technique will offer biologists a powerful tool for basic research in areas such as understanding of cell and gene functions and for biotechnological applications such as genome editing.
Collapse
Affiliation(s)
- Susana Martin-Ortigosa
- Center for Plant Transformation, Plant Sciences Institute and Department of Agronomy, Iowa State University, Ames, IA, 50011, USA,
| | | |
Collapse
|
10
|
Neutralization of Nogo-A enhances synaptic plasticity in the rodent motor cortex and improves motor learning in vivo. J Neurosci 2014; 34:8685-98. [PMID: 24966370 DOI: 10.1523/jneurosci.3817-13.2014] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The membrane protein Nogo-A is known as an inhibitor of axonal outgrowth and regeneration in the CNS. However, its physiological functions in the normal adult CNS remain incompletely understood. Here, we investigated the role of Nogo-A in cortical synaptic plasticity and motor learning in the uninjured adult rodent motor cortex. Nogo-A and its receptor NgR1 are present at cortical synapses. Acute treatment of slices with function-blocking antibodies (Abs) against Nogo-A or against NgR1 increased long-term potentiation (LTP) induced by stimulation of layer 2/3 horizontal fibers. Furthermore, anti-Nogo-A Ab treatment increased LTP saturation levels, whereas long-term depression remained unchanged, thus leading to an enlarged synaptic modification range. In vivo, intrathecal application of Nogo-A-blocking Abs resulted in a higher dendritic spine density at cortical pyramidal neurons due to an increase in spine formation as revealed by in vivo two-photon microscopy. To investigate whether these changes in synaptic plasticity correlate with motor learning, we trained rats to learn a skilled forelimb-reaching task while receiving anti-Nogo-A Abs. Learning of this cortically controlled precision movement was improved upon anti-Nogo-A Ab treatment. Our results identify Nogo-A as an influential molecular modulator of synaptic plasticity and as a regulator for learning of skilled movements in the motor cortex.
Collapse
|
11
|
Roscoe RF, Mactutus CF, Booze RM. HIV-1 transgenic female rat: synaptodendritic alterations of medium spiny neurons in the nucleus accumbens. J Neuroimmune Pharmacol 2014; 9:642-53. [PMID: 25037595 DOI: 10.1007/s11481-014-9555-z] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2013] [Accepted: 07/08/2014] [Indexed: 12/31/2022]
Abstract
HIV-1 associated neurocognitive deficits are increasing in prevalence, although the neuronal basis for these deficits is unclear. HIV-1 Tg rats constitutively express 7 of 9 HIV-associated proteins, and may be useful for studying the neuropathological substrates of HIV-1 associated neurocognitive disorders (HAND). In this study, adult female HIV-1 Tg rats and F344 control rats had similar growth rates, estrous cyclicity and startle reflex inhibition to a visual prepulse stimulus. Medium spiny neurons (MSNs) in the nucleus accumbens (NAcc) were ballistically-labeled utilizing the indocarbocyanine dye DiI. The branching complexity of MSNs in the NAcc was significantly decreased in HIV-1 Tg rats, relative to controls; moreover, the shorter length and decreased volume of dendritic spines, but unchanged head diameter, in HIV-1 Tg rats suggested a reduction of longer spines and an increase in shorter, less projected spines, indicating a population shift to a more immature spine phenotype. Collectively, these results from HIV-1 Tg female rats indicated significant synaptodendritic alterations of MSNs in the NAcc occur as a consequence of chronic, low-level, exposure to HIV-1 associated proteins.
Collapse
Affiliation(s)
- Robert F Roscoe
- Laboratory of Behavioral Neuroscience, Department of Psychology, University of South Carolina, 29208, Columbia, SC, USA
| | | | | |
Collapse
|
12
|
Zhang D, Das DB, Rielly CD. Potential of microneedle-assisted micro-particle delivery by gene guns: a review. Drug Deliv 2013; 21:571-87. [PMID: 24313864 DOI: 10.3109/10717544.2013.864345] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
CONTEXT Gene guns have been used to deliver deoxyribonucleic acid (DNA) loaded micro-particle and breach the muscle tissue to target cells of interest to achieve gene transfection. OBJECTIVE This article aims to discuss the potential of microneedle (MN) assisted micro-particle delivery from gene guns, with a view to reducing tissue damage. METHODS Using a range of sources, the main gene guns for micro-particle delivery are reviewed along with the primary features of their technology, e.g. their design configurations, the material selection of the micro-particle, the driving gas type and pressure. Depending on the gene gun system, the achieved penetration depths in the skin are discussed as a function of the gas pressure, the type of the gene gun system and particle size, velocity and density. The concept of MN-assisted micro-particles delivery which consists of three stages (namely, acceleration, separation and decoration stage) is discussed. In this method, solid MNs are inserted into the skin to penetrate the epidermis/dermis layer and create holes for particle injection. Several designs of MN array are discussed and the insertion mechanism is explored, as it determines the feasibility of the MN-based system for particle transfer. RESULTS This review suggests that one of the problems of gene guns is that they need high operating pressures, which may result in direct or indirect tissue/cells damage. MNs seem to be a promising method which if combined with the gene guns may reduce the operating pressures for these devices and reduce tissue/cell damages. CONCLUSIONS There is sufficient potential for MN-assisted particle delivery systems.
Collapse
Affiliation(s)
- Dongwei Zhang
- Department of Chemical Engineering, Loughborough University , Loughborough, Leicestershire , UK
| | | | | |
Collapse
|
13
|
Fluorescent nanoparticles for intracellular sensing: A review. Anal Chim Acta 2012; 751:1-23. [DOI: 10.1016/j.aca.2012.09.025] [Citation(s) in RCA: 237] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2012] [Revised: 09/13/2012] [Accepted: 09/16/2012] [Indexed: 12/31/2022]
|
14
|
Morgan JL, Kerschensteiner D. Coating particles with carbocyanine dyes. Cold Spring Harb Protoc 2011; 2011:1507-11. [PMID: 22135671 DOI: 10.1101/pdb.prot067041] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Imaging and reconstruction of developing neurons require cells that are labeled in a way that distinguishes them from their neighbors. This can be achieved with ballistic labeling, which refers to the delivery of a cell label by means of carrier particles (tungsten or gold) propelled from a pressurized gun. Ballistic delivery can reach many dispersed cells in one shot and can deploy a wide variety of cell markers to neurons in diverse preparations. The three most commonly used types of ballistic labels are carbocyanine dyes, dextran-conjugated fluorescent markers, and DNA plasmids. The primary advantage of ballistic labeling is that multiple dispersed cells can be labeled quickly in live or fixed tissue. This article describes a protocol for coating tungsten particles (∼1 µm in diameter) with carbocyanine dyes, which are widely used to label neurons in tissue and neural cells in suspension. These dyes are lipophilic and highly fluorescent within lipid bilayers. Because tissue damage worsens with the increasing pressure required for deeper bullet penetration, ballistic labeling of neurons is most effective when the target cells are near the surface of the preparation. This protocol was developed for labeling ganglion cells in retinal flat mounts.
Collapse
|
15
|
Seabold GK, Daunais JB, Rau A, Grant KA, Alvarez VA. DiOLISTIC labeling of neurons from rodent and non-human primate brain slices. J Vis Exp 2010:2081. [PMID: 20644510 PMCID: PMC3156079 DOI: 10.3791/2081] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
DiOLISTIC staining uses the gene gun to introduce fluorescent dyes, such as DiI, into neurons of brain slices (Gan et al., 2009; O'Brien and Lummis, 2007; Gan et al., 2000). Here we provide a detailed description of each step required together with exemplary images of good and bad outcomes that will help when setting up the technique. In our experience, a few steps proved critical for the successful application of DiOLISTICS. These considerations include the quality of the DiI-coated bullets, the extent of fixative exposure, and the concentration of detergent used in the incubation solutions. Tips and solutions for common problems are provided. This is a versatile labeling technique that can be applied to multiple animal species at a wide range of ages. Unlike other fluorescent labeling techniques that are limited to preparations from young animals or restricted to mice because they rely on the expression of a fluorescent transgene, DiOLISTIC labeling can be applied to animals of all ages, species and genotypes and it can be used in combination with immunostaining to identify a specific subpopulation of cells. Here we demonstrate the use of DiOLISTICS to label neurons in brain slices from adult mice and adult non-human primates with the purpose of quantifying dendrite branching and dendritic spine morphology.
Collapse
Affiliation(s)
- Gail K Seabold
- Section on Neuronal Structure, Laboratory for Integrative Neuroscience, NIH - National Institute of Health, Bethesda, MD, USA
| | | | | | | | | |
Collapse
|
16
|
Abstract
Neurons in vitro are different from any other cell types in their sensitivity and complexity. Growing, differentiating, transfecting, and recording from single neurons and neuronal networks all present particular challenges. Some of the difficulties arise from the small scale of cellular structures, and have already seen substantial advances due to nanotechnology, particularly highly fluorescent semiconductor nanoparticles. Other issues have less obvious solutions, but the complex and often surprising way that novel nanomaterials react with cells have suggested some revolutionary approaches. We review some of the ways nanomaterials and nanostructures can contribute to in vitro neuroscience, with a particular focus on emphasizing techniques that are widely accessible to many laboratories and on providing references to protocols and methods. The issues of nanotoxicology of greatest interest to cultured neurons are discussed. Finally, we present some future trends and challenges in nano-neuroscience.
Collapse
Affiliation(s)
- Daniel R Cooper
- Department of Biomedical Engineering, McGill University, 3775 Rue University, Montreal, QC H3A 2B4 Canada.
| | | |
Collapse
|