1
|
Zangl P, Collart C, Persoons R. Air, Skin, and Biological Monitoring of French Fire Instructors' Exposure to Particles/PAHs During Controlled Fire and Mitigation Strategies. TOXICS 2025; 13:106. [PMID: 39997920 PMCID: PMC11860349 DOI: 10.3390/toxics13020106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2024] [Revised: 12/31/2024] [Accepted: 01/10/2025] [Indexed: 02/26/2025]
Abstract
Occupational exposure as a firefighter was recently classified as carcinogenic to humans by the IARC. Fire instructors' exposure to carcinogenic PAHs is a major concern, and studies that have tried to assess the determinants of their exposure are scarce. An air and biomonitoring study was conducted in fire instructors performing simulated training exercises in enclosed containers. Air samples were collected, as well as urine samples from 22 firefighting instructors, and skin wipes were collected from FFs' skin at the end of the exercises. PAH metabolites (1-hydroxypyrene, 3-hydroxybenzo(a)pyrene, 2/3-hydroxyfluorene, and 2/3-hydroxyphenanthrene) were measured in urine samples at three sampling times (beginning of shift, end of shift, and next morning). Airborne PAHs were dominated by low molecular weight compounds (naphthalene), and levels were as high as 67 µg·m-3 close to the containers, decreasing at higher distances. Skin contamination was observed both on the neck/face and hands/wrists of fire instructors and pilots. Ten times lower skin contamination was observed when nitrile undergloves were worn. High internal exposure was measured, with 1-hydroxypyrene and 3-hydroxybenzo(a)pyrene levels frequently exceeding maximum recommended values in occupational settings (up to 2.8 µmol/mol creatinine for 1-OHP, 14 µmol/mol creatinine for ΣOH-PAH, and 1.0 nmol/mol creatinine for 3-OHBaP), whereas benzene exposure was revealed to be very low. These types of exposure were found to derive both from dermal absorption (combustion products deposited on the skin) and inhalation (when removing SCBA outside the containers). Several recommendations are proposed in order to reduce both exposure routes (nitrile undergloves and half-masks in the vicinity of containers), harmonise decontamination (PPEs) and cleaning procedures, and prevent the dermal absorption of PAH from turnout gear. This study emphasises the complex PAH exposure profiles of fire instructors and characterises the main drivers of exposure, highlighting the need for better mitigation strategies.
Collapse
Affiliation(s)
- Pauline Zangl
- Service Départemental d’Incendie et de Secours (SDIS) Isère, 38000 Grenoble, France; (P.Z.); (C.C.)
- Grenoble Teaching Hospital, EPSP-TIMC Laboratory, Université Grenoble Alpes, 38400 Grenoble, France
| | - Clément Collart
- Service Départemental d’Incendie et de Secours (SDIS) Isère, 38000 Grenoble, France; (P.Z.); (C.C.)
| | - Renaud Persoons
- Grenoble Teaching Hospital, EPSP-TIMC Laboratory, Université Grenoble Alpes, 38400 Grenoble, France
| |
Collapse
|
2
|
Lovén K, Hagvall L, Rex J, Nilsson CA, Malmborg V, Pagels J, Strandberg B, Hedmer M. Characterization of exposure to air pollutants for workers in and around fires. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2024; 21:878-894. [PMID: 39418654 DOI: 10.1080/15459624.2024.2406244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2024]
Abstract
Firefighters can be occupationally exposed to a wide range of airborne pollutants during fire-extinguishing operations. The overall study aim was to characterize occupational exposure to smoke for several groups of workers responding to fires, with specific aims to determine the correlations between exposure markers and to biologically assess their systemic exposure to polycyclic aromatic hydrocarbons (PAHs) in urine. Personal exposure measurements of equivalent black carbon (eBC), elemental carbon (EC), organic carbon (OC), nitrogen dioxide (NO2), PAHs, lung deposited surface area (LDSA), and particle number concentration (PNC) of ultrafine particles were performed on firefighters, observers, and post-fire workers during firefighting exercises. Urine samples were collected before and after exposure and analyzed for PAH metabolites. Additional routes for PAH skin exposure were investigated by wipe sampling on defined surfaces: equipment, personal protective equipment (PPE), and vehicles. Among workers without PPE, observers generally had higher exposures than post-fire workers. The observers and post-fire workers had an occupational exposure to smoke measured e.g. as EC of 7.3 µg m-3 and 1.9 µg m-3, respectively. There was a good agreement between measurements of carbonaceous particles measured as EC from filters and as eBC with high time resolution, especially for the observers and post-fire workers. Ultrafine particle exposure measured as LDSA was two times higher for observers compared to the post-fire workers. The urinary levels of PAH metabolites were generally higher in firefighters and observers compared to post-fire workers. Investigation of PAH contamination on firefighters' PPE revealed high PAH contamination on surfaces with frequent skin contact both before and after cleaning. Exposure to smoke can be assessed with several different exposure markers. For workers residing unprotected around fire scenes, there can be high peak exposures depending on their behavior concerning the smoke plume. Several workers had high urinary PAH metabolite concentrations even though they were exposed to low air concentrations of PAHs, indicating skin absorption of PAH as a plausible exposure route.
Collapse
Affiliation(s)
- Karin Lovén
- Division of Occupational and Environmental Medicine, Department of Laboratory Medicine, Lund University, Lund, Sweden
- Department of Occupational and Environmental Medicine, Region Skåne, Lund, Sweden
| | - Lina Hagvall
- Division of Occupational and Environmental Medicine, Department of Laboratory Medicine, Lund University, Lund, Sweden
- Department of Occupational and Environmental Medicine, Region Skåne, Lund, Sweden
| | - Johannes Rex
- Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Lund University, Lund, Sweden
| | - Carina A Nilsson
- Department of Occupational and Environmental Medicine, Region Skåne, Lund, Sweden
| | - Vilhelm Malmborg
- Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Lund University, Lund, Sweden
| | - Joakim Pagels
- Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Lund University, Lund, Sweden
| | - Bo Strandberg
- Division of Occupational and Environmental Medicine, Department of Laboratory Medicine, Lund University, Lund, Sweden
- Department of Occupational and Environmental Medicine, Region Skåne, Lund, Sweden
| | - Maria Hedmer
- Division of Occupational and Environmental Medicine, Department of Laboratory Medicine, Lund University, Lund, Sweden
- Department of Occupational and Environmental Medicine, Region Skåne, Lund, Sweden
| |
Collapse
|
3
|
Grünfeld J, Møller P, Vogel U, Jensen SP, Kofoed-Sørensen V, Andersen MHG. Assessment of Polycyclic Aromatic Hydrocarbon Exposure in Trainee Firefighters Using PAH CALUX Bioassay. TOXICS 2024; 12:825. [PMID: 39591003 PMCID: PMC11598809 DOI: 10.3390/toxics12110825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2024] [Revised: 11/04/2024] [Accepted: 11/14/2024] [Indexed: 11/28/2024]
Abstract
This work investigated the application of a reporter gene bioassay in assessing polycyclic aromatic hydrocarbon (PAH) exposure in trainee firefighters. In the PAH CALUX bioassay, the PAH-induced activation of the aryl hydrocarbon receptor in a reporter cell line is recorded by increased luminescence. A repeated measurement study was performed, collecting urine and skin wipe samples at two baseline sessions (spring and autumn) and after three firefighting sessions: one with wood fuel, one with gas fuel, and one without fire. The bioassay response was expressed as benzo[a]pyrene equivalents, which was compared to levels of 16 EPA criteria PAHs in skin wipe samples and 8 hydroxylated PAHs (OH-PAHs) in urine samples quantified by chromatography-tandem mass spectrometry techniques. Benzo[a]pyrene equivalents and PAH levels in skin wipes indicated larger exposure to PAHs during the wood session compared to the other sessions. The urine bioassay showed non-significant effect sizes after all sessions, whereas the chemical analysis showed increased OH-PAH levels after the gas session. The non-significant changes observed for the session without fire suggest a negligible exposure from contaminated gear. In conclusion, the bioassay response for skin wipes shows that trainee firefighters were exposed to higher levels of potentially toxic PAHs during the wood fire training session.
Collapse
Affiliation(s)
- Johanna Grünfeld
- The National Research Centre for the Working Environment, 2100 Copenhagen, Denmark
- Department of Public Health, Section of Environmental Health, University of Copenhagen, 1014 Copenhagen, Denmark
| | - Peter Møller
- Department of Public Health, Section of Environmental Health, University of Copenhagen, 1014 Copenhagen, Denmark
| | - Ulla Vogel
- The National Research Centre for the Working Environment, 2100 Copenhagen, Denmark
| | - Simon Pelle Jensen
- The National Research Centre for the Working Environment, 2100 Copenhagen, Denmark
| | - Vivi Kofoed-Sørensen
- The National Research Centre for the Working Environment, 2100 Copenhagen, Denmark
| | | |
Collapse
|
4
|
Frederiksen M, Jensen SP, Andersen MHG, Vogel U, Saber AT. Online SPE-LC-MS-MS method for eight hydroxylated metabolites of polycyclic aromatic hydrocarbons in urine and determination of optimal sampling time after firefighter training. Toxicol Lett 2024; 400:9-15. [PMID: 38977139 DOI: 10.1016/j.toxlet.2024.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 07/01/2024] [Accepted: 07/02/2024] [Indexed: 07/10/2024]
Abstract
Polycyclic aromatic compounds (PAHs) are formed during incomplete combustion and firefighters are inadvertently at risk of being exposed to these and other hazardous compounds. Exposure to PAHs is often estimated by measuring their hydroxylated metabolites (OH-PAH) in urine. Here, an online-SPE LC-MS-MS method was set up for eight OH-PAHs thus increasing sample throughput and minimizing manual handling. The method was validated over a 5-month period and showed good reproducibility with intra- and inter-day variation of 2.4-8.1 % and 1.6-6.5 %, respectively, of low-level samples and accuracy (91.6-104.8 %) for a standard reference material. The method was applied to urine samples from conscripts training to become firefighters to determine the optimal sampling time for this training activity before a large intervention study. In total, six conscripts sampled urine 6-8 times over a 40-hr period during a 3-day training course. All eight metabolites were detected in ≥ 97 % of the samples and showed peak excretion 4-6 hrs after the training corresponding to 8-10 hrs after first exposure. Samples taken the morning after the exercise contained low levels of most metabolites. Consequently, 4-6 hrs post exposure is recommended as the optimal sampling time for quantification of PAH exposure and monitoring of potential differences in exposure.
Collapse
Affiliation(s)
- Marie Frederiksen
- The National Research Centre for the Working Environment, Lersø Parkalle 105, Copenhagen 2100, Denmark.
| | - Simon Pelle Jensen
- The National Research Centre for the Working Environment, Lersø Parkalle 105, Copenhagen 2100, Denmark
| | | | - Ulla Vogel
- The National Research Centre for the Working Environment, Lersø Parkalle 105, Copenhagen 2100, Denmark; DTU Food, Technical University of Denmark, Kgs. Lyngby 2800, Denmark
| | - Anne Thoustrup Saber
- The National Research Centre for the Working Environment, Lersø Parkalle 105, Copenhagen 2100, Denmark
| |
Collapse
|
5
|
Cardona B, Rodgers KM, Trowbridge J, Buren H, Rudel RA. Breast Cancer-Related Chemical Exposures in Firefighters. TOXICS 2024; 12:707. [PMID: 39453127 PMCID: PMC11511222 DOI: 10.3390/toxics12100707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 09/12/2024] [Accepted: 09/20/2024] [Indexed: 10/26/2024]
Abstract
To fill a research gap on firefighter exposures and breast cancer risk, and guide exposure reduction, we aimed to identify firefighter occupational exposures linked to breast cancer. We conducted a systematic search and review to identify firefighter chemical exposures and then identified the subset that was associated with breast cancer. To do this, we compared the firefighter exposures with chemicals that have been shown to increase breast cancer risk in epidemiological studies or increase mammary gland tumors in experimental toxicology studies. For each exposure, we assigned a strength of evidence for the association with firefighter occupation and for the association with breast cancer risk. We identified twelve chemicals or chemical groups that were both linked to breast cancer and were firefighter occupational exposures, including polycyclic aromatic hydrocarbons, volatile aromatics, per- and polyfluoroalkyl substances, persistent organohalogens, and halogenated organophosphate flame retardants. Many of these were found at elevated levels in firefighting environments and were statistically significantly higher in firefighters after firefighting or when compared to the general population. Common exposure sources included combustion byproducts, diesel fuel and exhaust, firefighting foams, and flame retardants. Our findings highlight breast-cancer-related chemical exposures in the firefighting profession to guide equitable worker's compensation policies and exposure reduction.
Collapse
Affiliation(s)
| | - Kathryn M. Rodgers
- Department of Environmental Health, Boston University School of Public Health, Boston, MA 02118, USA
| | - Jessica Trowbridge
- Department of Obstetrics Gynecology and Reproductive Sciences, University of California San Francisco, San Francisco, CA 94143, USA
| | - Heather Buren
- United Fire Service Women, San Francisco, CA 94140, USA
| | | |
Collapse
|
6
|
Lang F, Wollschläger D, Letzel DIS, Roßbach B. Renal excretion of 1,2-dihydroxynaphthalene (DHN) in firefighting instructors after exposure to polycyclic aromatic hydrocarbons (PAHs) during live fire training. Sci Rep 2024; 14:15230. [PMID: 38956405 PMCID: PMC11219744 DOI: 10.1038/s41598-024-62388-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 05/16/2024] [Indexed: 07/04/2024] Open
Abstract
Exposure of firefighting instructors to polycyclic aromatic hydrocarbons (PAHs) such as naphthalene is unavoidable during live fire training. The study aimed to investigate naphthalene uptake by measuring the urinary excretion of the naphthalene metabolite 1,2-dihydroxynaphthalene (DHN), to describe the DHN elimination kinetics and to evaluate the results by comparison to further biomarkers of PAH exposure. N = 6 male non-smoking firefighting instructors completed five training sessions each in a residential fire simulation unit under respiratory protection. All participants provided two urine samples before and another seven samples within an 18-h-interval after each session. DHN was detected by gas chromatography/tandem mass spectrometry (GC-MS/MS) in all samples (n = 237) with median concentrations ranging from 3.3 µg/g crea. (range 0.9-10.2) before exposure to 134.2 µg/g crea. (43.4-380.4) post exposure. Maximum elimination found 3.3 h (median) after onset of exposure decreased with a mean half-life of 6.6 h to 27.1 µg/g crea. (15.7-139.5) 18 h after training. DHN sensitively indicated a presumed dermal naphthalene intake during training, showing similar elimination kinetics like other naphthalene metabolites. Internal exposure of the participants transiently exceeded exposures determined for non-smokers in the general population, but was lower than at other workplaces with PAH exposure. Despite limited uptake, accumulation is possible with daily exposure.
Collapse
Affiliation(s)
- Felix Lang
- Institute of Occupational, Social and Environmental Medicine, University Medical Center, Johannes Gutenberg-University, Obere Zahlbacher Strasse 67, 55131, Mainz, Germany.
| | - Daniel Wollschläger
- Institute of Medical Biostatistics, Epidemiology and Informatics (IMBEI), University Medical Center, Johannes Gutenberg-University, Mainz, Germany
| | - Dipl-Ing Stephan Letzel
- Institute of Occupational, Social and Environmental Medicine, University Medical Center, Johannes Gutenberg-University, Obere Zahlbacher Strasse 67, 55131, Mainz, Germany
| | - Bernd Roßbach
- Institute of Occupational, Social and Environmental Medicine, University Medical Center, Johannes Gutenberg-University, Obere Zahlbacher Strasse 67, 55131, Mainz, Germany
| |
Collapse
|
7
|
Bakali U, Baum JLR, Louzado-Feliciano P, Killawala C, Santiago KM, Pauley JL, Dikici E, Schaefer Solle N, Kobetz EN, Bachas LG, Deo SK, Caban-Martinez AJ, Daunert S. Characterization of fire investigators' polyaromatic hydrocarbon exposures using silicone wristbands. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2024; 278:116349. [PMID: 38714081 PMCID: PMC11215797 DOI: 10.1016/j.ecoenv.2024.116349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 03/31/2024] [Accepted: 04/16/2024] [Indexed: 05/09/2024]
Abstract
BACKGROUND Exposures to polyaromatic hydrocarbons (PAHs) contribute to cancer in the fire service. Fire investigators are involved in evaluations of post-fire scenes. In the US, it is estimated that there are up to 9000 fire investigators, compared to approximately 1.1 million total firefighting personnel. This exploratory study contributes initial evidence of PAH exposures sustained by this understudied group using worn silicone passive samplers. OBJECTIVES Evaluate PAH exposures sustained by fire investigators at post-fire scenes using worn silicone passive samplers. Assess explanatory factors and health risks of PAH exposure at post-fire scenes. METHODS As part of a cross-sectional study design, silicone wristbands were distributed to 16 North Carolina fire investigators, including eight public, seven private, and one public and private. Wristbands were worn during 46 post-fire scene investigations. Fire investigators completed pre- and post-surveys providing sociodemographic, occupational, and post-fire scene characteristics. Solvent extracts from wristbands were analyzed via gas chromatography-mass spectrometry (GC-MS). Results were used to estimate vapor-phase PAH concentration in the air at post-fire scenes. RESULTS Fire investigations lasted an average of 148 minutes, standard deviation ± 93 minutes. A significant positive correlation (r=0.455, p<.001) was found between investigation duration and PAH concentrations on wristbands. Significantly greater time-normalized PAH exposures (p=0.039) were observed for investigations of newer post-fire scenes compared to older post-fire scenes. Regulatory airborne PAH exposure limits were exceeded in six investigations, based on exposure to estimated vapor-phase PAH concentrations in the air at post-fire scenes. DISCUSSION Higher levels of off-gassing and suspended particulates at younger post-fire scenes may explain greater PAH exposure. Weaker correlations are found between wristband PAH concentration and investigation duration at older post-fire scenes, suggesting reduction of off-gassing PAHs over time. Exceedances of regulatory PAH limits indicate a need for protection against vapor-phase contaminants, especially at more recent post-fire scenes.
Collapse
Affiliation(s)
- Umer Bakali
- Department of Biochemistry and Molecular Biology, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA
| | - Jeramy L R Baum
- Department of Biochemistry and Molecular Biology, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA; Department of Chemistry, College of Arts and Sciences, University of Miami, Coral Gables, FL, USA
| | - Paola Louzado-Feliciano
- Department of Public Health Sciences, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA
| | - Chitvan Killawala
- Department of Biochemistry and Molecular Biology, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA; Department of Biomedical Engineering, College of Engineering, University of Miami, Coral Gables, FL, USA
| | - Katerina M Santiago
- Department of Public Health Sciences, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA
| | - Jeffrey L Pauley
- International Association of Arson Investigators, Bowie, MD, USA
| | - Emre Dikici
- Department of Biochemistry and Molecular Biology, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA; Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute of the University of Miami (BioNIUM), Miami, FL, USA
| | - Natasha Schaefer Solle
- Sylvester Comprehensive Cancer Center, University of Miami, Miami, FL, USA; Department of Medicine, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA
| | - Erin N Kobetz
- Department of Public Health Sciences, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA; Sylvester Comprehensive Cancer Center, University of Miami, Miami, FL, USA; Department of Medicine, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA
| | - Leonidas G Bachas
- Department of Chemistry, College of Arts and Sciences, University of Miami, Coral Gables, FL, USA
| | - Sapna K Deo
- Department of Biochemistry and Molecular Biology, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA; Sylvester Comprehensive Cancer Center, University of Miami, Miami, FL, USA; Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute of the University of Miami (BioNIUM), Miami, FL, USA
| | - Alberto J Caban-Martinez
- Department of Public Health Sciences, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA; Sylvester Comprehensive Cancer Center, University of Miami, Miami, FL, USA.
| | - Sylvia Daunert
- Department of Biochemistry and Molecular Biology, Leonard M. Miller School of Medicine, University of Miami, Miami, FL, USA; Sylvester Comprehensive Cancer Center, University of Miami, Miami, FL, USA; Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute of the University of Miami (BioNIUM), Miami, FL, USA
| |
Collapse
|
8
|
Paiva AM, Barros B, Oliveira M, Alves S, Esteves F, Fernandes A, Vaz J, Slezáková K, Teixeira JP, Costa S, Morais S. Biomonitoring of polycyclic aromatic hydrocarbons exposure and short-time health effects in wildland firefighters during real-life fire events. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 926:171801. [PMID: 38508274 DOI: 10.1016/j.scitotenv.2024.171801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 02/27/2024] [Accepted: 03/16/2024] [Indexed: 03/22/2024]
Abstract
Human biomonitoring data retrieved from real-life wildland firefighting in Europe and, also, worldwide are scarce. Thus, in this study, 176 Portuguese firefighters were biomonitored pre- and post- unsimulated wildfire combating (average:12-13 h; maximum: 55 h) to evaluate the impact on the levels of urinary polycyclic aromatic hydrocarbons hydroxylated metabolites (OHPAH; quantified by high-performance liquid chromatography with fluorescence detection) and the associated short-term health effects (symptoms, and total and differentiated white blood cells). Correlations between these variables and data retrieved from the self-reported questionnaires were also investigated. Firefighters were organized into four groups according to their exposure to wildfire emissions and their smoking habits: non-smoking non-exposed (NSNExp), non-smoking exposed (NSExp), smoking non-exposed (SNExp), and smoking and exposed (SExp). The most abundant metabolites were 1-hydroxynaphthalene and 1-hydroxyacenaphthene (1OHNaph + 1OHAce) (98-99 %), followed by 2-hydroxyfluorene (2OHFlu) (0.2-1.1 %), 1-hydroxyphenanthrene (1OHPhen) (0.2-0.4 %), and 1-hydroxypyrene (1OHPy) (0.1-0.2 %); urinary 3-hydroxybenzo(a)pyrene was not detected. The exposure to wildfire emissions significantly elevated the median concentrations of each individual and total OHPAH compounds in all groups, but this effect was more pronounced in non-smoking (1.7-4.2 times; p ≤ 0.006) than in smoking firefighters (1.3-1.6 times; p ≤ 0.03). The greatest discriminant of exposure to wildfire emissions was 1OHNaph + 1OHAce (increase of 4.2 times), while for tobacco smoke it was 2OHFlu (increase of 10 times). Post-exposure, white blood cells count significantly increased ranging from 1.4 (smokers, p = 0.025) to 3.7-fold (non-smokers, p < 0.001), which was accompanied by stronger significant correlations (0.480 < r < 0.882; p < 0.04) between individual and total OHPAH and total white blood cells (and lymphocytes > monocytes > neutrophils in non-smokers), evidencing the impact of PAH released from wildfire on immune cells. This study identifies Portuguese firefighters with high levels of biomarkers of exposure to PAH and points out the importance of adopting biomonitoring schemes, that include multiple biomarkers of exposure and biomarkers of effect, and implementing mitigations strategies.
Collapse
Affiliation(s)
- Ana Margarida Paiva
- REQUIMTE/LAQV, ISEP, Polytechnic of Porto, Rua Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Bela Barros
- REQUIMTE/LAQV, ISEP, Polytechnic of Porto, Rua Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Marta Oliveira
- REQUIMTE/LAQV, ISEP, Polytechnic of Porto, Rua Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Sara Alves
- Instituto Politécnico de Bragança, UICISA: E, Unidade de Investigação em Ciências da Saúde: Enfermagem, Campus de Santa Apolónia, 5300-253 Bragança, Portugal
| | - Filipa Esteves
- Environmental Health Department, National Institute of Health Dr. Ricardo Jorge, Rua Alexandre Herculano 321, 4000-055 Porto, Portugal; Department of Public Health and Forensic Sciences, Medical School, Faculty of Medicine, University of Porto, Rua Dr. Plácido da Costa, 4200-450 Porto, Portugal; EPIUnit, Instituto de Saúde Pública da Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal
| | - Adília Fernandes
- Instituto Politécnico de Bragança, UICISA: E, Unidade de Investigação em Ciências da Saúde: Enfermagem, Campus de Santa Apolónia, 5300-253 Bragança, Portugal
| | - Josiana Vaz
- CIMO, Instituto Politécnico de Bragança, Centro de Investigação de Montanha, Campus Santa Apolónia, 5300-253 Bragança, Portugal; SusTEC, Instituto Politécnico de Bragança, Sustec - Associate Laboratory for Sustainability and Technology in Inland Regions, Campus Santa Apolónia, 5300-253 Bragança, Portugal
| | - Klára Slezáková
- LEPABE-ALiCE, Departamento de Engenharia Química, Faculdade de Engenharia, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - João Paulo Teixeira
- Environmental Health Department, National Institute of Health Dr. Ricardo Jorge, Rua Alexandre Herculano 321, 4000-055 Porto, Portugal; EPIUnit, Instituto de Saúde Pública da Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal
| | - Solange Costa
- Environmental Health Department, National Institute of Health Dr. Ricardo Jorge, Rua Alexandre Herculano 321, 4000-055 Porto, Portugal; EPIUnit, Instituto de Saúde Pública da Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal
| | - Simone Morais
- REQUIMTE/LAQV, ISEP, Polytechnic of Porto, Rua Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal.
| |
Collapse
|
9
|
Lee NM, Tadesse AW, Ekpe OD, Lee SY, Kwon JW, Kim W, Cho YH, Oh JE. Assessment of PAH exposure and health risks among South Korean firefighters based on urinary PAH metabolites. CHEMOSPHERE 2024; 353:141429. [PMID: 38364917 DOI: 10.1016/j.chemosphere.2024.141429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 02/06/2024] [Accepted: 02/08/2024] [Indexed: 02/18/2024]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) comprise a group of compounds resulting from the incomplete combustion of organic matter. Firefighters engaged in fire suppression are highly exposed to PAHs. This study centered on evaluating the exposure levels and health risks of PAHs in South Korean firefighters involved in firefighting activities. The concentrations of 10 PAH metabolites in the urine of firefighters were measured immediately after, and two weeks post their engagement in extinguishing a large tire factory fire. The levels of OH-PAHs in urine samples immediately after fire suppression were elevated by a factor of 1.01-1.84 compared to urine samples from non-exposed period. The median concentration of total PAH metabolites (OH-PAHs) was higher in urine samples immediately after fire suppression (5910 ng/g creatinine) than in urine samples from non-exposed periods (5020 ng/g creatinine). However, the ∑OH-PAH levels in firefighters' urine were related to personal habits such as smoking. The concentrations of all individual OH-PAHs in the urine samples of nonsmokers exhibited a substantial increase, ranging from 1.37 to 2.3 times, clearly demonstrating that firefighting activities were a substantial source of PAH exposure. The calculated values associated with the health risks stemming from exposure to PAHs, including carcinogenic risk, total estimated daily intake (TEDI), and hazard quotients/index (HQs/HI), all fell within acceptable limits, indicating negligible risk. However, the HQ/HI values and TEDI for individual and total PAH exposures, except those for naphthalene, were 1.36-2.00 times higher in firefighters' samples taken after firefighting operations compared to those during regular duty. This underscores the need for more comprehensive investigations to comprehend the singular impact of firefighting activities due to the diverse sources of PAH emissions in the environment.
Collapse
Affiliation(s)
- Na Mi Lee
- Department of Civil and Environmental Engineering, Pusan National University, Busan, 46241, Republic of Korea
| | - Ababo Workineh Tadesse
- Department of Civil and Environmental Engineering, Pusan National University, Busan, 46241, Republic of Korea; Ambo University, Ambo, Ethiopia
| | - Okon Dominic Ekpe
- Department of Civil and Environmental Engineering, Pusan National University, Busan, 46241, Republic of Korea
| | - So Yun Lee
- National Fire Research Institute of Korea, Asan, 31555, Republic of Korea
| | - Ji Woon Kwon
- National Fire Research Institute of Korea, Asan, 31555, Republic of Korea
| | - Won Kim
- Wonjin Institute for Occupational and Environmental Health, Seoul, 02221, Republic of Korea
| | - Young Hwan Cho
- Wonjin Institute for Occupational and Environmental Health, Seoul, 02221, Republic of Korea
| | - Jeong-Eun Oh
- Department of Civil and Environmental Engineering, Pusan National University, Busan, 46241, Republic of Korea; Institute for Environment and Energy, Pusan National University, Busan, 46241, Republic of Korea.
| |
Collapse
|
10
|
Koslitz S, Heinrich B, Käfferlein HU, Koch HM, Pelzl T, Pitzke K, Köster D, Weiß T, Harth V, Brüning T, Behrens T, Taeger D. Biomonitoring of polycyclic aromatic hydrocarbons in firefighters at fire training facilities and in employees at respiratory protection and hose workshops. Front Public Health 2023; 11:1277812. [PMID: 38152667 PMCID: PMC10751366 DOI: 10.3389/fpubh.2023.1277812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 11/03/2023] [Indexed: 12/29/2023] Open
Abstract
Introduction Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic to humans and are formed by incomplete combustion. PAHs are always present during firefighting operations, and fire department members can be exposed to them in the workplace. Methods In this study, we analyzed 1-hydroxypyrene (1-OHP) in 36 urine samples from nine firefighters, collected before and after fire training sessions, and 32 urine samples from eight employees at respiratory protection and hose workshops. To assess breakthrough PAH exposure through personal protective equipment and potential dermal uptake, some of the workshop employees wore cotton garments under their regular workwear. Cotton samples were then examined for the presence of 17 semi-volatile and low-volatility PAHs. Results After firefighting exercises, we observed approximately a fivefold increase in mean 1-OHP concentrations in samples from firefighters, from 0.24 μg/L to 1.17 μg/L (maximum: 5.31 μg/L). In contrast, 1-OHP levels in workshop employees were found to be low, with the majority of urine samples yielding concentrations below the limit of quantification (LOQ: 0.05 μg/L, maximum: 0.11 μg/L). Similarly, low PAH levels were found on the workshop employees' cotton undergarments, with maximum concentrations of 250 and 205 ng/g for pyrene and benzo[a]pyrene, respectively. Discussion In conclusion, significant increases in 1-OHP in urine were observed in firefighters after training sessions, whereas work-related exposure remained low among workshop employees.
Collapse
Affiliation(s)
- Stephan Koslitz
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Birgit Heinrich
- Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA), Sankt Augustin, Germany
| | - Heiko U. Käfferlein
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Holger M. Koch
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Tim Pelzl
- Department of Fire Services, Rescue Services, and Fire Protection of the German Social Accident Insurance, German Social Accident Insurance Institution for the Public Sector in Baden-Württemberg, Stuttgart, Germany
| | - Katrin Pitzke
- Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA), Sankt Augustin, Germany
| | - Daniel Köster
- Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA), Sankt Augustin, Germany
| | - Tobias Weiß
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Volker Harth
- Institute for Occupational and Maritime Medicine (ZfAM), University Medical Centre Hamburg-Eppendorf (UKE), Hamburg, Germany
| | - Thomas Brüning
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Thomas Behrens
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Dirk Taeger
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| |
Collapse
|
11
|
Pálešová N, Maitre L, Stratakis N, Řiháčková K, Pindur A, Kohoutek J, Šenk P, Bartošková Polcrová A, Gregor P, Vrijheid M, Čupr P. Firefighters and the liver: Exposure to PFAS and PAHs in relation to liver function and serum lipids (CELSPAC-FIREexpo study). Int J Hyg Environ Health 2023; 252:114215. [PMID: 37418783 DOI: 10.1016/j.ijheh.2023.114215] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 06/23/2023] [Accepted: 06/23/2023] [Indexed: 07/09/2023]
Abstract
INTRODUCTION Firefighting is one of the most hazardous occupations due to exposure to per- and polyfluoroalkyl substances (PFAS) and polycyclic aromatic hydrocarbons (PAHs). Such exposure is suspected to affect the cardiometabolic profile, e.g., liver function and serum lipids. However, only a few studies have investigated the impact of this specific exposure among firefighters. METHODS Men included in the CELSPAC-FIREexpo study were professional firefighters (n = 52), newly recruited firefighters in training (n = 58), and controls (n = 54). They completed exposure questionnaires and provided 1-3 samples of urine and blood during the 11-week study period to allow assessment of their exposure to PFAS (6 compounds) and PAHs (6 compounds), and to determine biomarkers of liver function (alanine aminotransferase (ALT), gamma-glutamyl transferase (GGT), aspartate aminotransferase (AST), alkaline phosphatase (ALP) and total bilirubin (BIL)) and levels of serum lipids (total cholesterol (CHOL), low-density lipoprotein cholesterol (LDL) and triglycerides (TG)). The associations between biomarkers were investigated both cross-sectionally using multiple linear regression (MLR) and Bayesian weighted quantile sum (BWQS) regression and prospectively using MLR. The models were adjusted for potential confounders and false discovery rate correction was applied to account for multiplicity. RESULTS A positive association between exposure to PFAS and PAH mixture and BIL (β = 28.6%, 95% CrI = 14.6-45.7%) was observed by the BWQS model. When the study population was stratified, in professional firefighters and controls the mixture showed a positive association with CHOL (β = 29.5%, CrI = 10.3-53.6%) and LDL (β = 26.7%, CrI = 8.3-48.5%). No statistically significant associations with individual compounds were detected using MLR. CONCLUSIONS This study investigated the associations between exposure to PFAS and PAHs and biomarkers of cardiometabolic health in the Czech men, including firefighters. The results suggest that higher exposure to a mixture of these compounds is associated with an increase in BIL and the alteration of serum lipids, which can result in an unfavourable cardiometabolic profile.
Collapse
Affiliation(s)
- Nina Pálešová
- RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic
| | - Léa Maitre
- ISGlobal, Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain; CIBER de Epidemiología y Salud Pública (CIBERESP), Madrid, Spain
| | - Nikos Stratakis
- ISGlobal, Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain; CIBER de Epidemiología y Salud Pública (CIBERESP), Madrid, Spain
| | - Katarína Řiháčková
- RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic
| | - Aleš Pindur
- RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic; Faculty of Sports Studies, Masaryk University, Kamenice 753/5, 625 00, Czech Republic; Training Centre of Fire Rescue Service, Fire Rescue Service of the Czech Republic, Ministry of the Interior, Trnkova 85, 628 00, Brno, Czech Republic
| | - Jiří Kohoutek
- RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic
| | - Petr Šenk
- RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic
| | | | - Petr Gregor
- RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic
| | - Martine Vrijheid
- ISGlobal, Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain; CIBER de Epidemiología y Salud Pública (CIBERESP), Madrid, Spain
| | - Pavel Čupr
- RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic.
| |
Collapse
|
12
|
Barros B, Oliveira M, Morais S. Biomonitoring of firefighting forces: a review on biomarkers of exposure to health-relevant pollutants released from fires. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART B, CRITICAL REVIEWS 2023; 26:127-171. [PMID: 36748115 DOI: 10.1080/10937404.2023.2172119] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Occupational exposure as a firefighter has recently been classified as a carcinogen to humans by International Agency for Research on Cancer (IARC). Biomonitoring has been increasingly used to characterize exposure of firefighting forces to contaminants. However, available data are dispersed and information on the most relevant and promising biomarkers in this context of firefighting is missing. This review presents a comprehensive summary and critical appraisal of existing biomarkers of exposure including volatile organic compounds such as polycyclic aromatic hydrocarbons, several other persistent other organic pollutants as well as heavy metals and metalloids detected in biological fluids of firefighters attending different fire scenarios. Urine was the most characterized matrix, followed by blood. Firefighters exhaled breath and saliva were poorly evaluated. Overall, biological levels of compounds were predominantly increased in firefighters after participation in firefighting activities. Biomonitoring studies combining different biomarkers of exposure and of effect are currently limited but exploratory findings are of high interest. However, biomonitoring still has some unresolved major limitations since reference or recommended values are not yet established for most biomarkers. In addition, half-lives values for most of the biomarkers have thus far not been defined, which significantly hampers the design of studies. These limitations need to be tackled urgently to improve risk assessment and support implementation of better more effective preventive strategies.
Collapse
Affiliation(s)
- Bela Barros
- REQUIMTE-LAQV,Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Porto, Portugal
| | - Marta Oliveira
- REQUIMTE-LAQV,Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Porto, Portugal
| | - Simone Morais
- REQUIMTE-LAQV,Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Porto, Portugal
| |
Collapse
|
13
|
Taeger D, Koslitz S, Käfferlein HU, Pelzl T, Heinrich B, Breuer D, Weiss T, Harth V, Behrens T, Brüning T. Exposure to polycyclic aromatic hydrocarbons assessed by biomonitoring of firefighters during fire operations in Germany. Int J Hyg Environ Health 2023; 248:114110. [PMID: 36634384 DOI: 10.1016/j.ijheh.2023.114110] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 12/16/2022] [Accepted: 01/04/2023] [Indexed: 01/12/2023]
Abstract
BACKGROUND Firefighters are exposed to a variety of hazardous substances including carcinogens such as polycyclic aromatic hydrocarbons (PAH) during firefighting. In order to minimize the uptake of such substances into the body, firefighters wear personal protective equipment. Only few data exist from real-life firefighting missions and under common although highly variable exposure scenarios such as fighting fires in residential buildings, outdoor, and vehicle fires. The aim of this study is to assess the levels of 1-Hydroxypyrene (1-OHP) as marker for incorporated PAH during firefighting operations in Germany using biomonitoring methods. METHODS We analyzed urine samples for 1-OHP from 77 firefighters who reported firefighting operations (with and without creatinine adjustment). Urine samples were collected before (baseline) and, where applicable, after firefighting operations at three time points subsequent (2-4, 6-8, and 12 h). RESULTS Compared to the baseline measurements, mean 1-OHP concentrations after firefighting missions were doubled (0.14 vs. 0.31 μg/L urine, 0.13 μg/g vs. 0.27 μg/g creatinine) and this increase was observed 2-4 h after firefighting. Firefighting in residential buildings (N = 54) and of outdoor and vehicle fires (N = 17) occurred most frequently, whereas blazes, vegetation fires, and fires in underground facilities (N = 6) were rarely encountered. For residential building fires, a 3-fold increase in mean 1-OPH concentrations was observed, whereas no increase could be observed for outdoor and vehicle fires. The highest increase was observed for firefighters with interior attack missions (0.11 μg/L vs. 0.48 μg/L 1-OHP) despite the use of self-contained breathing apparatus (SCBA). During the suppression of outdoor or vehicle fires using SCBA, again, no increase was observed. Although PAH are taken up during certain firefighting missions, the 1-OHP levels almost entirely remained (in 64 of the 77 reported missions) within the normal range of the German general population, i.e., below the reference levels (95th percentiles) of smokers (0.73 μg/g creatinine) and non-smokers (0.30 μg/g creatine). CONCLUSION Under study conditions, properly applied protective clothing and wearing of SCBA led to a significant reduction of PAH exposure levels. But there are individual situations in which PAH are increasingly incorporated since the incorporation depends on several factors and can be extremely variable. In contrast to many workplaces with high occupational exposure levels, firefighters are not exposed to PAH on a daily basis. Nevertheless, the possibility of an individual increased cancer risk for a particular firefighter cannot completely be ruled out.
Collapse
Affiliation(s)
- Dirk Taeger
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany.
| | - Stephan Koslitz
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Heiko U Käfferlein
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Tim Pelzl
- Unfallkasse Baden-Württemberg (UKBW), Germany
| | - Birgit Heinrich
- Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA), Sankt Augustin, Germany
| | - Dietmar Breuer
- Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA), Sankt Augustin, Germany
| | - Tobias Weiss
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Volker Harth
- Institute for Occupational and Maritime Medicine (ZfAM), University Medical Centre Hamburg-Eppendorf (UKE), Germany
| | - Thomas Behrens
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| | - Thomas Brüning
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bochum, Germany
| |
Collapse
|
14
|
Horn GP, Stakes K, Neumann DL, Madrzykowski D, Fent KW. Exposure Risks and Potential Control Measures for a Fire Behavior Lab Training Structure: Part B. Chemical Gas Concentrations. FIRE TECHNOLOGY 2023; 59:3255-3282. [PMID: 38650825 PMCID: PMC11034741 DOI: 10.1007/s10694-023-01447-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 06/09/2023] [Indexed: 04/25/2024]
Abstract
Firefighters' or instructors' exposure to airborne chemicals during live-fire training may depend on fuels being burned, fuel orientation and participants' location within the structure. This study was designed to evaluate the impact of different control measures on exposure risk to combustion byproducts during fire dynamics training where fuel packages are mounted at or near the ceiling. These measures included substitution of training fuels (low density wood fiberboard, oriented strand board (OSB), pallets, particle board, plywood) and adoption of engineering controls such as changing the location of the instructor and students using the structure. Experiments were conducted for two different training durations: the typical six ventilation cycle (6-cycle) and a shorter three ventilation cycle (3-cycle) with a subset of training fuels. In Part A of this series, we characterized the fire dynamics within the structure, including the ability of each fuel to provide an environment that achieves the training objectives. Here, in Part B, airborne chemical concentrations are reported at the location where fire instructors would typically be operating. We hypothesized that utilizing a training fuel package with solid wood pallets would result in lower concentrations of airborne contaminants at the rear instructor location than wood-based sheet products containing additional resins and/or waxes. In the 6-cycle experiments (at the rear instructor location), OSB-fueled fires produced the highest median concentrations of benzene and 1,3 butadiene, plywood-fueled fires produced the highest total polycyclic aromatic hydrocarbon (PAH) concentrations, particle board-fueled fires produced the highest methyl isocyanate concentrations, and pallet-fueled fires produced the highest hydrogen chloride concentrations. All fuels other than particle board produced similarly high levels of formaldehyde at the rear instructor location. The OSB fuel package created the most consistent fire dynamics over 6-cycles, while fiberboard resulted in consistent fire dynamics only for the first three cycles. In the follow-on 3-cycle experiment, PAH, benzene, and aldehyde concentrations were similar for the OSB and fiberboard-fueled fires. Air sampling did not identify any clear differences between training fires from burning solid wood pallets and those that incorporate wood-based sheet products for this commonly employed fuel arrangement with fuels mounted high in the compartment. However, it was found that exposure can be reduced by moving firefighters and instructors lower in the compartment and/or by moving the instructor in charge of ventilation from the rear of the structure (where highest concentrations were consistently measured) to an outside position.
Collapse
Affiliation(s)
- Gavin P Horn
- Fire Safety Research Institute, UL Research Institutes, 6200 Old Dobbin Lane, Suite 150, Columbia, MD, 21045, USA
| | - Keith Stakes
- Fire Safety Research Institute, UL Research Institutes, 6200 Old Dobbin Lane, Suite 150, Columbia, MD, 21045, USA
| | - Danielle L Neumann
- Asset and Sustainability Performance, UL Solutions, Lake Forest, CA, USA
| | - Daniel Madrzykowski
- Fire Safety Research Institute, UL Research Institutes, 6200 Old Dobbin Lane, Suite 150, Columbia, MD, 21045, USA
| | - Kenneth W Fent
- National Institute for Occupational Safety & Health, Cincinnati, OH, USA
| |
Collapse
|
15
|
Scherer G, Scherer M, Rögner N, Pluym N. Assessment of the exposure to polycyclic aromatic hydrocarbons in users of various tobacco/nicotine products by suitable urinary biomarkers. Arch Toxicol 2022; 96:3113-3126. [PMID: 35909193 DOI: 10.1007/s00204-022-03349-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Accepted: 07/21/2022] [Indexed: 11/02/2022]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) occur naturally (bitumen and oils) and are formed during all incomplete combustions of organic materials. PAH exposure sources are manifold and include specific workplaces, ambient air, various foodstuffs, tobacco smoke and some medications. At least four members of this class of chemicals have been classified as proven or probable human carcinogens. Assessment of the exposure to PAHs with suitable methods is of importance, particularly in users of new-generation tobacco/nicotine products, which are intended to replace combustible cigarettes (CCs), a major source of non-occupational exposure to PAHs. In a clinical study comprising a period of 74 h under confinement, we investigated the exposure to naphthalene (Nap), fluorene (Flu), phenanthrene (Phe), pyrene (Pyr) and benzo[a]pyrene (BaP) by measuring urinary monohydroxy-PAH (OH-PAH) derived from these parent compounds in habitual users of CCs, electronic cigarettes (ECs), heated tobacco products (HTPs), oral tobacco (OT), and nicotine replacement therapy products (NRTs). Non-users (NU) of any tobacco/nicotine products served as (negative) control group. Smokers exhibited the highest levels for all PAH biomarkers measured, almost all of which were significantly different from the NU and user groups of all other products investigated. CC smokers were the only group which showed a significant relationship between almost all PAH biomarkers and dose markers such as daily consumption, urinary nicotine equivalents (Nequ) and plasma cotinine (CotP). The ratios in urinary OH-PAH between CC and all other groups were dependent on the biomarker and range from < 2 to > 10. These ratios could at least partly be explained by the enzymes involved, their region-selectivity and inducibility by smoking. In conclusion, cigarette smokers (CC) were the only group, which showed product use dependent exposure to PAHs, whereas users of EC, HTP, NRT and OT were not distinguishable from NU of any tobacco/nicotine products.
Collapse
Affiliation(s)
- Gerhard Scherer
- ABF, Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstraße 5, 82152, Planegg, Germany.
| | - Max Scherer
- ABF, Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstraße 5, 82152, Planegg, Germany
| | - Nadine Rögner
- ABF, Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstraße 5, 82152, Planegg, Germany
| | - Nikola Pluym
- ABF, Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstraße 5, 82152, Planegg, Germany
| |
Collapse
|
16
|
Sousa G, Teixeira J, Delerue-Matos C, Sarmento B, Morais S, Wang X, Rodrigues F, Oliveira M. Exposure to PAHs during Firefighting Activities: A Review on Skin Levels, In Vitro/In Vivo Bioavailability, and Health Risks. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:12677. [PMID: 36231977 PMCID: PMC9565977 DOI: 10.3390/ijerph191912677] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 09/30/2022] [Accepted: 09/30/2022] [Indexed: 06/16/2023]
Abstract
Occupational exposure as a firefighter is a complex activity that continuously exposes subjects to several health hazards including fire emissions during firefighting. Firefighters are exposed to polycyclic aromatic hydrocarbons (PAHs), known as toxic, mutagenic, and carcinogenic compounds, by inhalation, dermal contact, and ingestion. In this work, a literature overview of firefighters' dermal exposure to PAHs after firefighting and data retrieved from skin in vitro/in vivo studies related to their dermal absorption, bioavailability, and associated toxicological and carcinogenic effects are reviewed. The evidence demonstrates the contamination of firefighters' skin with PAHs, mainly on the neck (2.23-62.50 ng/cm2), wrists (0.37-8.30 ng/cm2), face (2.50-4.82 ng/cm2), and hands (1.59-4.69 ng/cm2). Concentrations of possible/probable carcinogens (0.82-33.69 ng/cm2), including benzopyrene isomers, were found on firefighters' skin. PAHs penetrate the skin tissues, even at low concentrations, by absorption and/or diffusion, and are locally metabolized and distributed by the blood route to other tissues/organs. Lighter PAHs presented increased dermal permeabilities and absorption rates than heavier compounds. Topical PAHs activate the aryl hydrocarbon receptor and promote the enzymatic generation of reactive intermediates that may cause protein and/or DNA adducts. Future research should include in vitro/in vivo assays to perform a more realistic health risk assessment and to explore the contribution of dermal exposure to PAHs total internal dose.
Collapse
Affiliation(s)
- Gabriel Sousa
- REQUIMTE/LAQV, Instituto Superior de Engenharia, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Joana Teixeira
- REQUIMTE/LAQV, Instituto Superior de Engenharia, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Cristina Delerue-Matos
- REQUIMTE/LAQV, Instituto Superior de Engenharia, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Bruno Sarmento
- CESPU-Instituto de Investigação e Formação Avançada em Ciências e Tecnologias da Saúde, Instituto Universitário de Ciências da Saúde, 4585-116 Gandra, Portugal
- Instituto de Investigação e Inovação em Saúde, Universidade do Porto, 4200-135 Porto, Portugal
| | - Simone Morais
- REQUIMTE/LAQV, Instituto Superior de Engenharia, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Xianyu Wang
- QAEHS-Queensland Alliance for Environmental Health Sciences, The University of Queensland, Woolloongabba, QLD 4102, Australia
| | - Francisca Rodrigues
- REQUIMTE/LAQV, Instituto Superior de Engenharia, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| | - Marta Oliveira
- REQUIMTE/LAQV, Instituto Superior de Engenharia, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
| |
Collapse
|
17
|
Horn GP, Fent KW, Kerber S, Smith DL. Hierarchy of contamination control in the fire service: Review of exposure control options to reduce cancer risk. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2022; 19:538-557. [PMID: 35853136 PMCID: PMC9928012 DOI: 10.1080/15459624.2022.2100406] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The international fire service community is actively engaged in a wide range of activities focused on development, testing, and implementation of effective approaches to reduce exposure to contaminants and the related cancer risk. However, these activities are often viewed independent of each other and in the absence of the larger overall effort of occupational health risk mitigation. This narrative review synthesizes the current research on fire service contamination control in the context of the National Institute for Occupational Safety and Health (NIOSH) Hierarchy of Controls, a framework that supports decision making around implementing feasible and effective control solutions in occupational settings. Using this approach, we identify evidence-based measures that have been investigated and that can be implemented to protect firefighters during an emergency response, in the fire apparatus and at the fire station, and identify several knowledge gaps that remain. While a great deal of research and development has been focused on improving personal protective equipment for the various risks faced by the fire service, these measures are considered less effective. Administrative and engineering controls that can be used during and after the firefight have also received increased research interest in recent years. However, less research and development have been focused on higher level control measures such as engineering, substitution, and elimination, which may be the most effective, but are challenging to implement. A comprehensive approach that considers each level of control and how it can be implemented, and that is mindful of the need to balance contamination risk reduction against the fire service mission to save lives and protect property, is likely to be the most effective.
Collapse
Affiliation(s)
- Gavin P Horn
- Fire Safety Research Institute, UL Research Institutes, Columbia, Maryland
- Illinois Fire Service Institute, Champaign, Illinois
| | - Kenneth W Fent
- National Institute for Occupational Safety & Health, Cincinnati, Ohio
| | - Steve Kerber
- Fire Safety Research Institute, UL Research Institutes, Columbia, Maryland
| | - Denise L Smith
- Illinois Fire Service Institute, Champaign, Illinois
- Skidmore College, Saratoga Springs, New York
| |
Collapse
|
18
|
Louro H, Gomes BC, Saber AT, Iamiceli AL, Göen T, Jones K, Katsonouri A, Neophytou CM, Vogel U, Ventura C, Oberemm A, Duca RC, Fernandez MF, Olea N, Santonen T, Viegas S, Silva MJ. The Use of Human Biomonitoring to Assess Occupational Exposure to PAHs in Europe: A Comprehensive Review. TOXICS 2022; 10:toxics10080480. [PMID: 36006159 PMCID: PMC9414426 DOI: 10.3390/toxics10080480] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/05/2022] [Accepted: 08/13/2022] [Indexed: 06/02/2023]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) are among the chemicals with proven impact on workers' health. The use of human biomonitoring (HBM) to assess occupational exposure to PAHs has become more common in recent years, but the data generated need an overall view to make them more usable by regulators and policymakers. This comprehensive review, developed under the Human Biomonitoring for Europe (HBM4EU) Initiative, was based on the literature available from 2008-2022, aiming to present and discuss the information on occupational exposure to PAHs, in order to identify the strengths and limitations of exposure and effect biomarkers and the knowledge needs for regulation in the workplace. The most frequently used exposure biomarker is urinary 1-hydroxypyrene (1-OH-PYR), a metabolite of pyrene. As effect biomarkers, those based on the measurement of oxidative stress (urinary 8-oxo-dG adducts) and genotoxicity (blood DNA strand-breaks) are the most common. Overall, a need to advance new harmonized approaches both in data and sample collection and in the use of appropriate biomarkers in occupational studies to obtain reliable and comparable data on PAH exposure in different industrial sectors, was noted. Moreover, the use of effect biomarkers can assist to identify work environments or activities of high risk, thus enabling preventive risk mitigation and management measures.
Collapse
Affiliation(s)
- Henriqueta Louro
- Department of Human Genetics, National Institute of Health Dr. Ricardo Jorge (INSA), Av. Padre Cruz, 1649-016 Lisbon, Portugal
- Centre for Toxicogenomics and Human Health (ToxOmics), Nova Medical School, Universidade NOVA de Lisboa, Campo dos Mártires da Pátria, 130, 1169-056 Lisbon, Portugal
| | - Bruno Costa Gomes
- Department of Human Genetics, National Institute of Health Dr. Ricardo Jorge (INSA), Av. Padre Cruz, 1649-016 Lisbon, Portugal
- Centre for Toxicogenomics and Human Health (ToxOmics), Nova Medical School, Universidade NOVA de Lisboa, Campo dos Mártires da Pátria, 130, 1169-056 Lisbon, Portugal
| | - Anne Thoustrup Saber
- National Research Centre for the Working Environment, DK-2100 Copenhagen, Denmark
| | | | - Thomas Göen
- IPASUM, Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany
| | - Kate Jones
- Health and Safety Executive, Buxton, Derbyshire SK17 9JN, UK
| | - Andromachi Katsonouri
- Cyprus State General Laboratory, Ministry of Health, P.O. Box 28648, Nicosia 2081, Cyprus
| | - Christiana M. Neophytou
- Cyprus State General Laboratory, Ministry of Health, P.O. Box 28648, Nicosia 2081, Cyprus
- Department of Life Sciences, European University Cyprus, Nicosia 2404, Cyprus
| | - Ulla Vogel
- National Research Centre for the Working Environment, DK-2100 Copenhagen, Denmark
- National Food Institute, Technical University of Denmark, Kemitorvet, Bygning 202, DK-2800 Kgs Lyngby, Denmark
| | - Célia Ventura
- Department of Human Genetics, National Institute of Health Dr. Ricardo Jorge (INSA), Av. Padre Cruz, 1649-016 Lisbon, Portugal
- Centre for Toxicogenomics and Human Health (ToxOmics), Nova Medical School, Universidade NOVA de Lisboa, Campo dos Mártires da Pátria, 130, 1169-056 Lisbon, Portugal
| | - Axel Oberemm
- German Federal Institute for Risk Assessment, Max-Dohrn-Straße 8-10, 10589 Berlin, Germany
| | - Radu Corneliu Duca
- Unit Environmental Hygiene and Human Biological Monitoring, Department of Health Protection, Laboratoire National de Santé (LNS), 1, Rue Louis Rech, 3555 Dudelange, Luxembourg
- Centre for Environment and Health, Department of Public Health and Primary Care, KU Leuven (University of Leuven), O&N 5b, Herestraat 49, 3000 Leuven, Belgium
| | - Mariana F. Fernandez
- Centre of Biomedical Research (CIBM), University of Granada, 18016 Granada, Spain
- Biosanitary Research Institute of Granada (ibs.GRANADA), 18012 Granada, Spain
- CIBER de Epidemiología y Salud Pública (CIBERESP), 28029 Madrid, Spain
| | - Nicolas Olea
- Centre of Biomedical Research (CIBM), University of Granada, 18016 Granada, Spain
- Biosanitary Research Institute of Granada (ibs.GRANADA), 18012 Granada, Spain
- CIBER de Epidemiología y Salud Pública (CIBERESP), 28029 Madrid, Spain
| | - Tiina Santonen
- Finnish Institute of Occupational Health, 00250 Helsinki, Finland
| | - Susana Viegas
- Public Health Research Centre, NOVA National School of Public Health, Universidade NOVA de Lisboa, 1600-560 Lisbon, Portugal
- Comprehensive Health Research Center (CHRC), 1169-056 Lisbon, Portugal
| | - Maria João Silva
- Department of Human Genetics, National Institute of Health Dr. Ricardo Jorge (INSA), Av. Padre Cruz, 1649-016 Lisbon, Portugal
- Centre for Toxicogenomics and Human Health (ToxOmics), Nova Medical School, Universidade NOVA de Lisboa, Campo dos Mártires da Pátria, 130, 1169-056 Lisbon, Portugal
| |
Collapse
|
19
|
Hwang J, Xu C, Grunsted P, Agnew RJ, Malone TR, Clifton S, Thompson K, Xu X. Urinary Metabolites of Polycyclic Aromatic Hydrocarbons in Firefighters: A Systematic Review and Meta-Analysis. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:8475. [PMID: 35886320 PMCID: PMC9318785 DOI: 10.3390/ijerph19148475] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 07/05/2022] [Accepted: 07/06/2022] [Indexed: 02/04/2023]
Abstract
Firefighters are intermittently exposed to complex, mixed pollutants in random settings. Of those pollutants, PAHs (polycyclic aromatic hydrocarbons) are the most commonly studied and best understood. PAH exposure can occur via multiple routes; therefore, the levels of hydroxylated metabolites of PAHs in urine have been used as a biomonitoring tool for risk assessment. We performed a systematic review and meta-analysis of the literature to estimate the levels of urinary hydroxylated PAH (OHPAH) among firefighters, determine risk attributions, and, finally, evaluate the scope of preventive efforts and their utility as diagnostic tools. The meta-regression confirmed increases in OHPAH concentrations after fire activities by up to 1.71-times (p-values: <0.0001). Samples collected at a time point of 2−4 h after a fire suppression showed a consistent, statistically significant pattern as compared with baseline samples. The National Fire Protection Association (NFPA) standard 1582 Standard on Comprehensive Occupational Medical Program for Fire Departments lists various health examinations, including a urinalysis for occupational chemical exposure if indicated and medical screening for cancers and cardiovascular diseases. Biomonitoring is a valuable screening tool for assessing occupational exposure and the results of this meta-analysis support their inclusion in regular health screenings for firefighters.
Collapse
Affiliation(s)
- Jooyeon Hwang
- Department of Occupational and Environmental Health, Hudson College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
| | - Chao Xu
- Department of Biostatistics and Epidemiology, Hudson College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA; (C.X.); (P.G.)
| | - Paul Grunsted
- Department of Biostatistics and Epidemiology, Hudson College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA; (C.X.); (P.G.)
| | - Robert J. Agnew
- Fire Protection & Safety Engineering Technology Program, College of Engineering, Architecture and Technology, Oklahoma State University, Stillwater, OK 74078, USA;
| | - Tara R. Malone
- Department of Health Sciences Library and Information Management, Graduate College, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA; (T.R.M.); (S.C.)
| | - Shari Clifton
- Department of Health Sciences Library and Information Management, Graduate College, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA; (T.R.M.); (S.C.)
| | - Krista Thompson
- Department of Internal Medicine, University of Texas Southwestern Medical School, Dallas, TX 75390, USA;
| | - Xin Xu
- Shanghai Anti-Doping Laboratory, Shanghai University of Sport, Shanghai 200438, China;
| |
Collapse
|
20
|
Bakali U, Baum JLR, Killawala C, Kobetz EN, Solle NS, Deo SK, Caban-Martinez AJ, Bachas LG, Daunert S. Mapping carcinogen exposure across urban fire incident response arenas using passive silicone-based samplers. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2021; 228:112929. [PMID: 34768049 DOI: 10.1016/j.ecoenv.2021.112929] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 09/05/2021] [Accepted: 10/19/2021] [Indexed: 06/13/2023]
Abstract
Carcinogens are emitted in significant quantities at fire scenes and are a major contributor in the increased cancer risk observed in firefighters when compared to the general population. A knowledge gap exists in the current understanding of the distribution of these toxic compounds within a localized fire incident response arena. Here, we employ stationary silicone-based passive samplers at controlled live fire trainings to evaluate the deposition behavior of polyaromatic hydrocarbons (PAHs) emitted by fires. Our findings indicate significantly greater total PAH exposure in fires fueled by biomass and wood compared to fires burning cleaner fuels, such as propane. A 22% increase in total PAH deposition and a 68% increase in high molecular weight PAH deposition was recorded for biomass fueled fires compared to propane fueled fires. Furthermore, we observe that heavier molecular weight PAHs exhibit a pronounced deposition front within a certain radius of the hot zone, whereas low molecular weight PAHs are more uniformly distributed throughout the area. These findings highlight that the warm zones and cold zones of fire situations yield elevated levels of carcinogen exposure to first responders within them. We anticipate that these findings will help inform decisions made by emergency personnel when evaluating risk for the hot zone, warm zone, and cold zone of urban fires helping ease the carcinogenic risk experienced.
Collapse
Affiliation(s)
- Umer Bakali
- Department of Biochemistry and Molecular Biology University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Jeramy L R Baum
- Department of Chemistry, University of Miami, Coral Gables, FL, USA
| | - Chitvan Killawala
- Department of Biochemistry and Molecular Biology University of Miami, Miller School of Medicine, Miami, FL, USA; Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA
| | - Erin N Kobetz
- Public Health Sciences and Sylvester Comprehensive Cancer Center, USA; Medicine and Sylvester Comprehensive Cancer Center, USA; Sylvester Comprehensive Cancer Center, USA
| | - Natasha Schaefer Solle
- Medicine and Sylvester Comprehensive Cancer Center, USA; Sylvester Comprehensive Cancer Center, USA
| | - Sapna K Deo
- Department of Biochemistry and Molecular Biology University of Miami, Miller School of Medicine, Miami, FL, USA; Sylvester Comprehensive Cancer Center, USA
| | - Alberto J Caban-Martinez
- Public Health Sciences and Sylvester Comprehensive Cancer Center, USA; Sylvester Comprehensive Cancer Center, USA
| | | | - Sylvia Daunert
- Department of Biochemistry and Molecular Biology University of Miami, Miller School of Medicine, Miami, FL, USA; Sylvester Comprehensive Cancer Center, USA.
| |
Collapse
|
21
|
Alharbi BH, Pasha MJ, Al-Shamsi MAS. Firefighter exposures to organic and inorganic gas emissions in emergency residential and industrial fires. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 770:145332. [PMID: 33515879 DOI: 10.1016/j.scitotenv.2021.145332] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 01/17/2021] [Accepted: 01/17/2021] [Indexed: 06/12/2023]
Abstract
The gas emissions generated from fires could cause mortalities and diseases in firefighters. Gas emissions from fire contain a mixture of a wide range of organic and inorganic gases, depending on several elements that are not currently known. In this study, firefighters were equipped with portable gas detectors to measure selected organic and inorganic gases in 26 emergency fire incidents. The fire incidents were categorized as industrial or residential based on their source. The exposure of firefighters to volatile organic compounds (VOCs) in residential fires was double that in industrial fires. This is probably due to the contents of the houses, as more VOCs are released from textiles and furniture. The concentration of toluene, which is widely used in cosmetics and paints in housing, was fifteen-fold higher in residential fires than industrial fires. The exposure of firefighters to inorganic gases was much higher in industrial fires than residential fires. The concentration of hydrogen chloride, which is generated from the combustion of chlorinated plastics, such as industrial pipes and cables, in industrial fires was 18-fold higher than that in residential fires. Additionally, in this study, we found that the concentration of VOCs that poses cancer and non-cancer health risk to firefighters increases in residential fire incidents to almost three times that in industrial fire incidents. Hydrogen sulfide and sulfur dioxide concentrations were higher in industrial fire incidents than in residential fire incidents. The level of hydrogen sulfide and sulfur dioxide were 19-fold and 8-fold higher, respectively, in industrial fire incidents than in residential fire incidents. This study reveals that gas emissions vary widely between industrial and residential fires.
Collapse
Affiliation(s)
- Badr H Alharbi
- National Centre for Environmental Technology (NCET), Life Science & Environment Research Institute (LSERI), King Abdulaziz City for Science & Technology (KACST), Saudi Arabia
| | - Mohammad J Pasha
- National Centre for Environmental Technology (NCET), Life Science & Environment Research Institute (LSERI), King Abdulaziz City for Science & Technology (KACST), Saudi Arabia
| | - Mohammed Ahmad S Al-Shamsi
- National Centre for Environmental Technology (NCET), Life Science & Environment Research Institute (LSERI), King Abdulaziz City for Science & Technology (KACST), Saudi Arabia.
| |
Collapse
|