1
|
Zhang Y, Mi F, Zhao Y, Geng P, Zhang S, Song H, Chen G, Yan B, Guan M. Multifunctional nanozymatic biosensors: Awareness, regulation and pathogenic bacteria detection. Talanta 2025; 292:127957. [PMID: 40154048 DOI: 10.1016/j.talanta.2025.127957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2024] [Revised: 02/24/2025] [Accepted: 03/15/2025] [Indexed: 04/01/2025]
Abstract
It is estimated that approximately 700,000 fatalities occur annually due to infections attributed to various pathogens, which are capable of dissemination via multiple environmental vectors, including air, water, and soil. Consequently, there is an urgent need to enhance and refine rapid detection technologies for pathogens to prevent and control the spread of associated diseases. This review focuses on applying nanozymes in constructing biosensors, particularly their advancement in detecting pathogenic bacteria. Nanozymes, which are nanomaterials exhibiting enzyme-like activity, combine unique magnetic, optical, and electronic properties with structural diversity. This blend of characteristics makes them highly appealing for use in biocatalytic applications. Moreover, their nanoscale dimensions facilitate effective contact with pathogenic bacteria, leading to efficient detection and antibacterial effects. This article briefly summarizes the development, classification, and strategies for regulating the catalytic activity of nanozymes. It primarily focuses on recent advancements in constructing biosensors that utilize nanozymes as probes for sensitively detecting pathogenic bacteria. The discussion covers the development of various optical and electrochemical biosensors, including colorimetric, fluorescence, surface-enhanced Raman scattering (SERS), and electrochemical methods. These approaches provide a reliable solution for the sensitive detection of pathogenic bacteria. Finally, the challenges and future development directions of nanozymes in pathogen detection are discussed.
Collapse
Affiliation(s)
- Yiyao Zhang
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China
| | - Fang Mi
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China.
| | - Yajun Zhao
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China
| | - Pengfei Geng
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China
| | - Shan Zhang
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China
| | - Han Song
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China
| | - Guotong Chen
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China
| | - Bo Yan
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China
| | - Ming Guan
- College of Chemistry and Chemical Engineering, Xinjiang Normal University, Urumqi, 830054, China.
| |
Collapse
|
2
|
Chen Y, Dai L, Zhang F, Zhao T, Jin S. A Sensitive Fluorescence Analysis Method of Pathogenic Microorganisms Based on Silicon Photomultiplier. J Fluoresc 2024:10.1007/s10895-024-03872-w. [PMID: 39180572 DOI: 10.1007/s10895-024-03872-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 07/29/2024] [Indexed: 08/26/2024]
Abstract
The monitoring of pathogenic microorganisms in water is important for public health and disease outbreaks prediction. Recently, optical detection techniques have drawn much attention due to the advantages of rapid response, security and high sensitivity. In this paper, a fluorescence spectrometer based on 375 nm exciting laser and the microchannel liquid sample flow technology is proposed. The 4 × 4 narrowband filter array was coupled to a Silicon Photomultiplier (SiPM) array with single-photon sensitivity. B500 fluorescent microspheres and Escherichia coli were used for performance evaluation of the spectrometer. As a result, it is feasible to use random particle counting method to detect the bacteria concentration level in water even low to several CFU/mL. In addition, based on Python tools and neural network algorithm models, the fluorescence spectra of different kinds of substances (biotic and abiotic) can be classified with an accuracy of more than 97%. The method was successfully applied to tap water samples. The results suggest that the proposed method is applicable for on-site bacteria detection.
Collapse
Affiliation(s)
- Yi Chen
- College of Optics and Electronic Science and Technology, China Jiliang University, Hangzhou, China
| | - Licheng Dai
- College of Optics and Electronic Science and Technology, China Jiliang University, Hangzhou, China
| | - Fei Zhang
- College of Optics and Electronic Science and Technology, China Jiliang University, Hangzhou, China
| | - Tianqi Zhao
- College of Optics and Electronic Science and Technology, China Jiliang University, Hangzhou, China.
| | - Shangzhong Jin
- College of Optics and Electronic Science and Technology, China Jiliang University, Hangzhou, China.
| |
Collapse
|
3
|
Chen J, Zhong J, Lei H, Ai Y. Label-free multidimensional bacterial characterization with an ultrawide detectable concentration range by microfluidic impedance cytometry. LAB ON A CHIP 2023; 23:5029-5038. [PMID: 37909182 DOI: 10.1039/d3lc00799e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/02/2023]
Abstract
Rapid and accurate identification of bacteria is of great importance to public health in various fields, including medical diagnostics, food safety, and environmental monitoring. However, most existing bacterial detection methods have very narrow detectable concentration ranges and limited detection information, which easily leads to wrong diagnosis and treatment. This work presents a novel high-throughput microfluidic electrical impedance-based multidimensional single-bacterium profiling system for ultrawide concentration range detection and accurate differentiation of viability and Gram types of bacteria. The electrical impedance-based microfluidic cytometry is capable of multi-frequency impedance quantification, which allows profiling of the bacteria size, concentration, and membrane impedance as an indicator of bacterial viability and Gram properties in a single flow-through interrogation. It has been demonstrated that this novel impedance cytometry has an ultrawide bacterial counting range (102-108 cells per mL), and exhibits a rapid and accurate discrimination of viability and Gram types of bacteria in a label-free manner. Escherichia coli (E. coli) has been used as an analog species for the accuracy assessment of the electrical impedance-based bacterial detection system in an authentic complex beverage matrix within 24 hours. The impedance-based quantifications of viable bacteria are consistent with those obtained by the classical bacterial colony counting method (R2 = 0.996). This work could pave the way for providing a novel microfluidic cytometry system for rapid and multidimensional bacterial detection in diverse areas.
Collapse
Affiliation(s)
- Jiahong Chen
- Guangdong Provincial Key Laboratory of Food Quality and Safety/National-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou 510642, China.
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou 510642, China
| | - Jianwei Zhong
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore.
| | - Hongtao Lei
- Guangdong Provincial Key Laboratory of Food Quality and Safety/National-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou 510642, China.
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou 510642, China
| | - Ye Ai
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore.
| |
Collapse
|
4
|
Du M, Ma J, Zhang Z, Wu G, Wu J, Wang H, Xie X, Wang C. Direct, ultrafast, and sensitive detection of environmental pathogenic microorganisms based on a graphene biosensor. Anal Chim Acta 2023; 1279:341810. [PMID: 37827618 DOI: 10.1016/j.aca.2023.341810] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 09/06/2023] [Accepted: 09/08/2023] [Indexed: 10/14/2023]
Abstract
Pathogenic microorganisms in the environment pose a serious threat to global human health. This study developed a reduced graphene oxide (rGO)-field effect transistor (FET) biosensor to realize the rapid and sensitive detection of pathogenic microorganisms. The rGO-FET sensors were prepared by in-situ thermal reduction method, and biorecognition elements were immobilized using a crosslinking agent to realize the surface functionalization of rGO. The rGO-FET biosensors can detect Escherichia coli O157:H7 as low as 1.4 CFU mL-1 within 46 s. The normalized current response was linearly correlated with E. coli concentration in the range of 1.4-1.4 × 107 CFU mL-1. The normalized current response of E. coli O157:H7 was about an order of magnitude higher than those of other microorganisms, indicating that the biosensor has good specificity. The current loss rates of the unmodified rGO-FET sensors and the biosensors modified with anti-E. coli O157:H7 after 30 days of storage at 4 °C were approximately 8% and 15%, respectively. Most importantly, the rGO-FET biosensors can directly detect real samples without pretreatment. Compared with other technologies, the rGO-FET biosensors can detect pathogenic microorganisms with a wider linear range in a shorter time, which is of great importance for the rapid warning and control of pathogenic microorganisms in the environment.
Collapse
Affiliation(s)
- Manman Du
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China; Tianjin Key Lab of Indoor Air Environmental Quality Control, Tianjin, 300072, China; Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China
| | - Jinbiao Ma
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China; Tianjin Key Lab of Indoor Air Environmental Quality Control, Tianjin, 300072, China
| | - Zhiwei Zhang
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China
| | - Guangzu Wu
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China
| | - Jianguo Wu
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China; School of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin, 300222, China
| | - Hao Wang
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China; School of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin, 300222, China
| | - Xinwu Xie
- Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China; National Bio-Protection Engineering Center, Tianjin, 300161, China.
| | - Can Wang
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China; Tianjin Key Lab of Indoor Air Environmental Quality Control, Tianjin, 300072, China.
| |
Collapse
|
5
|
Asgari S, Dhital R, Mustapha A, Lin M. Duplex detection of foodborne pathogens using a SERS optofluidic sensor coupled with immunoassay. Int J Food Microbiol 2022; 383:109947. [PMID: 36191492 DOI: 10.1016/j.ijfoodmicro.2022.109947] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 09/19/2022] [Accepted: 09/20/2022] [Indexed: 11/16/2022]
Abstract
Herein, we developed a surface-enhanced Raman spectroscopy (SERS) optofluidic sensor coupled with immunoprobes to simultaneously separate and detect the foodborne pathogens, Escherichia coli O157:H7, and Salmonella in lettuce and packed salad. The method consists of three steps of (i) enrichment to enhance detection sensitivity, (ii) selective separation and labelling of target bacteria by their specific antibody-bearing SERS-nanotags and (iii) detection of tagged bacterial cells using SERS within a hydrodynamic flow-focusing SERS optofluidic device, where even low counts of bacterial cells were detectable in the very thin-film-like sample stream. SERS-nanotags consisted of different Raman reporter molecules, representing each species, i.e., the detection of Raman reporter confirms the presence of the target pathogen. The anti-E. coli antibody used in this study functions against all strains of E. coli O157:H7 and the anti-Salmonella antibody used in this work acts on a wide range of Salmonella enterica strains. Bacterial counts of 1000, 100, and 10 CFU/ 200 g sample were successfully detected after only 15 min enrichment. Our method showed a very low detection limit value of 10 CFU/ 200 g sample for the bacterial mixture in both lettuce and packed salad, proving the efficiency and high sensitivity of our method to detect multiple pathogens in the food samples. The total analysis time, including sample preparation for simultaneous detection of multiple bacteria, was estimated to be 2 h, which is much less than the time required in conventional methods. Hence, our proposed protocol is considered a promising rapid and efficient approach for pathogen screening of food samples.
Collapse
Affiliation(s)
- Sara Asgari
- Food Science Program, Division of Food, Nutrition & Exercise Sciences, University of Missouri, Columbia, MO 65211, USA
| | - Rajiv Dhital
- Food Science Program, Division of Food, Nutrition & Exercise Sciences, University of Missouri, Columbia, MO 65211, USA
| | - Azlin Mustapha
- Food Science Program, Division of Food, Nutrition & Exercise Sciences, University of Missouri, Columbia, MO 65211, USA
| | - Mengshi Lin
- Food Science Program, Division of Food, Nutrition & Exercise Sciences, University of Missouri, Columbia, MO 65211, USA.
| |
Collapse
|
6
|
Daniel F, Kesterson D, Lei K, Hord C, Patel A, Kaffenes A, Congivaram H, Prakash S. Application of Microfluidics for Bacterial Identification. Pharmaceuticals (Basel) 2022; 15:ph15121531. [PMID: 36558982 PMCID: PMC9781190 DOI: 10.3390/ph15121531] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Revised: 11/29/2022] [Accepted: 12/05/2022] [Indexed: 12/14/2022] Open
Abstract
Bacterial infections continue to pose serious public health challenges. Though anti-bacterial therapeutics are effective remedies for treating these infections, the emergence of antibiotic resistance has imposed new challenges to treatment. Often, there is a delay in prescribing antibiotics at initial symptom presentation as it can be challenging to clinically differentiate bacterial infections from other organisms (e.g., viruses) causing infection. Moreover, bacterial infections can arise from food, water, or other sources. These challenges have demonstrated the need for rapid identification of bacteria in liquids, food, clinical spaces, and other environments. Conventional methods of bacterial identification rely on culture-based approaches which require long processing times and higher pathogen concentration thresholds. In the past few years, microfluidic devices paired with various bacterial identification methods have garnered attention for addressing the limitations of conventional methods and demonstrating feasibility for rapid bacterial identification with lower biomass thresholds. However, such culture-free methods often require integration of multiple steps from sample preparation to measurement. Research interest in using microfluidic methods for bacterial identification is growing; therefore, this review article is a summary of current advancements in this field with a focus on comparing the efficacy of polymerase chain reaction (PCR), loop-mediated isothermal amplification (LAMP), and emerging spectroscopic methods.
Collapse
Affiliation(s)
- Fraser Daniel
- Department of Mechanical and Aerospace Engineering, College of Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Delaney Kesterson
- Center for Life Sciences Education, The Ohio State University, Columbus, OH 43210, USA
| | - Kevin Lei
- Department of Chemical and Biomolecular Engineering, College of Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Catherine Hord
- Center for Life Sciences Education, The Ohio State University, Columbus, OH 43210, USA
| | - Aarti Patel
- Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Anastasia Kaffenes
- Department of Neuroscience, College of Arts and Sciences and College of Medicine, The Ohio State University, Columbus, OH 43210, USA
| | - Harrshavasan Congivaram
- School of Health and Rehabilitation Sciences, College of Medicine, The Ohio State University, Columbus, OH 43210, USA
| | - Shaurya Prakash
- Department of Mechanical and Aerospace Engineering, College of Engineering, The Ohio State University, Columbus, OH 43210, USA
- Correspondence:
| |
Collapse
|
7
|
Valiūnienė A, Ziziunaite G, Virbickas P. Application of Prussian Blue in Electrochemical and Optical Sensing of Free Chlorine. SENSORS (BASEL, SWITZERLAND) 2022; 22:7768. [PMID: 36298120 PMCID: PMC9606938 DOI: 10.3390/s22207768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Revised: 09/30/2022] [Accepted: 10/10/2022] [Indexed: 06/16/2023]
Abstract
In this paper, an electrochemical free chlorine (FCL) sensor was formed by modifying a fluorine-doped tin oxide-coated glass slide (glass|FTO) with a layer of Prussian blue (glass|FTO|PB). The glass|FTO|PB sensor exhibited a wide linear detection range from 1.7 to 99.2 μmol L-1 of FCL with a sensitivity of ~0.8 µA cm-2 μmol-1 L and showed high selectivity for FCL. However, ClO3-, ClO4- and NO3- ions have induced only a negligible amperometric response that is highly beneficial for a real-life sample analysis as these ions are commonly found in chlorine-treated water. Moreover, in this work, optical absorption measurement-based investigations of partially reduced PB were carried out as a means to characterize PB catalytic activity towards FCL and to investigate the possibility of applying PB for the optical detection of FCL.
Collapse
|
8
|
Qiu B, Chen X, Xu F, Wu D, Zhou Y, Tu W, Jin H, He G, Chen S, Sun D. Nanofiber self-consistent additive manufacturing process for 3D microfluidics. MICROSYSTEMS & NANOENGINEERING 2022; 8:102. [PMID: 36119377 PMCID: PMC9477890 DOI: 10.1038/s41378-022-00439-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 07/22/2022] [Accepted: 07/27/2022] [Indexed: 06/13/2023]
Abstract
3D microfluidic devices have emerged as powerful platforms for analytical chemistry, biomedical sensors, and microscale fluid manipulation. 3D printing technology, owing to its structural fabrication flexibility, has drawn extensive attention in the field of 3D microfluidics fabrication. However, the collapse of suspended structures and residues of sacrificial materials greatly restrict the application of this technology, especially for extremely narrow channel fabrication. In this paper, a 3D printing strategy named nanofiber self-consistent additive manufacturing (NSCAM) is proposed for integrated 3D microfluidic chip fabrication with porous nanofibers as supporting structures, which avoids the sacrificial layer release process. In the NSCAM process, electrospinning and electrohydrodynamic jet (E-jet) writing are alternately employed. The porous polyimide nanofiber mats formed by electrospinning are ingeniously applied as both supporting structures for the suspended layer and percolating media for liquid flow, while the polydimethylsiloxane E-jet writing ink printed on the nanofiber mats (named construction fluid in this paper) controllably permeates through the porous mats. After curing, the resultant construction fluid-nanofiber composites are formed as 3D channel walls. As a proof of concept, a microfluidic pressure-gain valve, which contains typical features of narrow channels and movable membranes, was fabricated, and the printed valve was totally closed under a control pressure of 45 kPa with a fast dynamic response of 52.6 ms, indicating the feasibility of NSCAM. Therefore, we believe NSCAM is a promising technique for manufacturing microdevices that include movable membrane cavities, pillar cavities, and porous scaffolds, showing broad applications in 3D microfluidics, soft robot drivers or sensors, and organ-on-a-chip systems.
Collapse
Affiliation(s)
- Bin Qiu
- Fujian Micro/Nano Manufacturing Engineering Technology Research Center, Xiamen University, Xiamen, 361102 China
| | - Xiaojun Chen
- School of Mechanical and Electrical Engineering, Lingnan Normal University, Zhanjiang, 524000 China
| | - Feng Xu
- Fujian Micro/Nano Manufacturing Engineering Technology Research Center, Xiamen University, Xiamen, 361102 China
| | - Dongyang Wu
- Fujian Micro/Nano Manufacturing Engineering Technology Research Center, Xiamen University, Xiamen, 361102 China
| | - Yike Zhou
- Fujian Micro/Nano Manufacturing Engineering Technology Research Center, Xiamen University, Xiamen, 361102 China
| | - Wenchang Tu
- Fujian Micro/Nano Manufacturing Engineering Technology Research Center, Xiamen University, Xiamen, 361102 China
| | - Hang Jin
- Fujian Micro/Nano Manufacturing Engineering Technology Research Center, Xiamen University, Xiamen, 361102 China
| | - Gonghan He
- Fujian Micro/Nano Manufacturing Engineering Technology Research Center, Xiamen University, Xiamen, 361102 China
| | - Songyue Chen
- Fujian Micro/Nano Manufacturing Engineering Technology Research Center, Xiamen University, Xiamen, 361102 China
| | - Daoheng Sun
- Fujian Micro/Nano Manufacturing Engineering Technology Research Center, Xiamen University, Xiamen, 361102 China
| |
Collapse
|
9
|
Liu YS, Deng Y, Chen CK, Khoo BL, Chua SL. Rapid detection of microorganisms in a fish infection microfluidics platform. JOURNAL OF HAZARDOUS MATERIALS 2022; 431:128572. [PMID: 35278965 DOI: 10.1016/j.jhazmat.2022.128572] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 02/14/2022] [Accepted: 02/23/2022] [Indexed: 06/14/2023]
Abstract
Inadequate access to clean water is detrimental to human health and aquatic industries. Waterborne pathogens can survive prolonged periods in aquatic bodies, infect commercially important seafood, and resist water disinfection, resulting in human infections. Environmental agencies and research laboratories require a relevant, portable, and cost-effective platform to monitor microbial pathogens and assess their risk of infection on a large scale. Advances in microfluidics enable better control and higher precision than traditional culture-based pathogen monitoring approaches. We demonstrated a rapid, high-throughput fish-based teleost (fish)-microbe (TelM) microfluidic-based device that simultaneously monitors waterborne pathogens in contaminated waters and assesses their infection potential under well-defined settings. A chamber-associated port allows direct access to the animal, while the transparency of the TelM platform enables clear observation of sensor readouts. As proof-of-concept, we established a wound infection model using Pseudomonas aeruginosa-contaminated water in the TelM platform, where bacteria formed biofilms on the wound and secreted a biofilm metabolite, pyoverdine. Pyoverdine was used as fluorescent sensor to correlate P. aeruginosa contamination to infection. The TelM platform was validated with environmental waterborne microbes from marine samples. Overall, the TelM platform can be readily applied to assess microbial and chemical risk in aquatic bodies in resource-constrained settings.
Collapse
Affiliation(s)
- Yang Sylvia Liu
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China
| | - Yanlin Deng
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
| | - Chun Kwan Chen
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
| | - Bee Luan Khoo
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China; Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China; City University of Hong Kong - Futian Shenzhen Research Institute, China.
| | - Song Lin Chua
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China; State Key Laboratory of Chemical Biology and Drug Discovery, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China; Research Centre for Deep Space Explorations, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China; Shenzhen Key Laboratory of Food Biological Safety Control, China.
| |
Collapse
|
10
|
A Mobile Laboratory Enables Fecal Pollution Source Tracking in Catchments Using Onsite qPCR Assays. WATER 2022. [DOI: 10.3390/w14081224] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Onsite molecular diagnostics can revolutionize fecal pollution source tracking. We aimed to validate a method for onsite qPCR assays with a miniature speaker-sized Q qPCR instrument and other portable equipment items. We showed that marker genes for total bacteria (16S) and E. coli (rodA) in 100 mL of river water measured with this method agreed within ±0.3 log10 units with results obtained when using conventional laboratory equipment items. We then deployed the portable method in a mobile laboratory (‘lab in a van’) and quantified HF183 marker genes for human host associated Bacteroides in river water within 3 h of sampling. We also used the mobile laboratory to investigate urban river water and effluents from two storm drains and a retention pond and collected comprehensive microbial and physicochemical water quality data. We found significantly higher HF183 gene levels in the older storm drain compared to the river water (6.03 ± 0.04 vs. 4.23 ± 0.03 log10 gene copies per 100 mL), and a principal component analysis revealed that storm drain effluent retention in a pond beneficially altered water characteristics, making them more like those of the receiving river. In conclusion, onsite qPCR assays can be performed with portable equipment items to quickly test water.
Collapse
|
11
|
Trojanowicz M, Pyszynska M. Flow-Injection Methods in Water Analysis-Recent Developments. Molecules 2022; 27:1410. [PMID: 35209198 PMCID: PMC8879103 DOI: 10.3390/molecules27041410] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/11/2022] [Accepted: 02/15/2022] [Indexed: 12/10/2022] Open
Abstract
Widespread demand for the analysis and control of water quality and supply for human activity and ecosystem sustainability has necessitated the continuous improvement of water analysis methods in terms of their reliability, efficiency, and costs. To satisfy these requirements, flow-injection analysis using different detection methods has successfully been developed in recent decades. This review, based on about 100 original research papers, presents the achievements in this field over the past ten years. Various methodologies for establishing flow-injection measurements are reviewed, together with microfluidics and portable systems. The developed applications mostly concern not only the determination of inorganic analytes but also the speciation analysis of different elements, and the determination of several total indices of water quality. Examples of the determination of organic residues (e.g., pesticides, phenolic compounds, and surfactants) in natural surface waters, seawater, groundwater, and drinking water have also been identified. Usually, changes in the format of manual procedures for flow-injection determination results in the improvement of various operational parameters, such as the limits of detection, the sampling rate, or selectivity in different matrices.
Collapse
Affiliation(s)
- Marek Trojanowicz
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 02-195 Warsaw, Poland;
- Department of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| | - Marta Pyszynska
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 02-195 Warsaw, Poland;
| |
Collapse
|
12
|
Separation and detection of E. coli O157:H7 using a SERS-based microfluidic immunosensor. Mikrochim Acta 2022; 189:111. [DOI: 10.1007/s00604-022-05187-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 01/11/2022] [Indexed: 10/19/2022]
|
13
|
Xiang N, Ni Z. Hand-Powered Inertial Microfluidic Syringe-Tip Centrifuge. BIOSENSORS 2021; 12:14. [PMID: 35049644 PMCID: PMC8774109 DOI: 10.3390/bios12010014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Revised: 12/27/2021] [Accepted: 12/28/2021] [Indexed: 12/05/2022]
Abstract
Conventional sample preparation techniques require bulky and expensive instruments and are not compatible with next-generation point-of-care diagnostic testing. Here, we report a manually operated syringe-tip inertial microfluidic centrifuge (named i-centrifuge) for high-flow-rate (up to 16 mL/min) cell concentration and experimentally demonstrate its working mechanism and performance. Low-cost polymer films and double-sided tape were used through a rapid nonclean-room process of laser cutting and lamination bonding to construct the key components of the i-centrifuge, which consists of a syringe-tip flow stabilizer and a four-channel paralleled inertial microfluidic concentrator. The unstable liquid flow generated by the manual syringe was regulated and stabilized with the flow stabilizer to power inertial focusing in a four-channel paralleled concentrator. Finally, we successfully used our i-centrifuge for manually operated cell concentration. This i-centrifuge offers the advantages of low device cost, simple hand-powered operation, high-flow-rate processing, and portable device volume. Therefore, it holds potential as a low-cost, portable sample preparation tool for point-of-care diagnostic testing.
Collapse
Affiliation(s)
- Nan Xiang
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, China;
- State Key Laboratory of Bioelectronics, Southeast University, Nanjing 210096, China
| | - Zhonghua Ni
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, China;
- State Key Laboratory of Bioelectronics, Southeast University, Nanjing 210096, China
| |
Collapse
|
14
|
Poboży E, Trojanowicz M. Application of Capillary Electrophoresis for Determination of Inorganic Analytes in Waters. Molecules 2021; 26:6972. [PMID: 34834063 PMCID: PMC8625978 DOI: 10.3390/molecules26226972] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 11/12/2021] [Accepted: 11/15/2021] [Indexed: 11/16/2022] Open
Abstract
Aside from HPLC and GC, capillary electrophoresis (CE) is one of the most important techniques for high-performance separations in modern analytical chemistry. Its main advantages are the possibility of using different detection techniques, the possibility of in-capillary sample processing for preconcentration or derivatization, and ease of instrumental miniaturization down to the microfluidic scale. Those features are utilized in the separation of macromolecules in biochemistry and in genetic investigations, but they can be also used in determinations of inorganic ions in water analysis. This review, based on about 100 original research works, presents applications of CE methods in water analysis reported in recent decade, mostly regarding conductivity detection or indirect UV detection. The developed applications include analysis of high salinity sea waters, as well as analysis of other surface waters and drinking waters.
Collapse
Affiliation(s)
- Ewa Poboży
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland;
| | - Marek Trojanowicz
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland;
- Laboratory of Nuclear Analytical Techniques, Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw, Poland
| |
Collapse
|
15
|
Wang HB, Wu YH, Luo LW, Yu T, Xu A, Xue S, Chen GQ, Ni XY, Peng L, Chen Z, Wang YH, Tong X, Bai Y, Xu YQ, Hu HY. Risks, characteristics, and control strategies of disinfection-residual-bacteria (DRB) from the perspective of microbial community structure. WATER RESEARCH 2021; 204:117606. [PMID: 34500181 PMCID: PMC8390064 DOI: 10.1016/j.watres.2021.117606] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 08/19/2021] [Accepted: 08/23/2021] [Indexed: 05/19/2023]
Abstract
The epidemic of COVID-19 has aroused people's particular attention to biosafety. A growing number of disinfection products have been consumed during this period. However, the flaw of disinfection has not received enough attention, especially in water treatment processes. While cutting down the quantity of microorganisms, disinfection processes exert a considerable selection effect on bacteria and thus reshape the microbial community structure to a great extent, causing the problem of disinfection-residual-bacteria (DRB). These systematic and profound changes could lead to the shift in regrowth potential, bio fouling potential, as well as antibiotic resistance level and might cause a series of potential risks. In this review, we collected and summarized the data from the literature in recent 10 years about the microbial community structure shifting of natural water or wastewater in full-scale treatment plants caused by disinfection. Based on these data, typical DRB with the most reporting frequency after disinfection by chlorine-containing disinfectants, ozone disinfection, and ultraviolet disinfection were identified and summarized, which were the bacteria with a relative abundance of over 5% in the residual bacteria community and the bacteria with an increasing rate of relative abundance over 100% after disinfection. Furthermore, the phylogenic relationship and potential risks of these typical DRB were also analyzed. Twelve out of fifteen typical DRB genera contain pathogenic strains, and many were reported of great secretion ability. Pseudomonas and Acinetobacter possess multiple disinfection resistance and could be considered as model bacteria in future studies of disinfection. We also discussed the growth, secretion, and antibiotic resistance characteristics of DRB, as well as possible control strategies. The DRB phenomenon is not limited to water treatment but also exists in the air and solid disinfection processes, which need more attention and more profound research, especially in the period of COVID-19.
Collapse
Affiliation(s)
- Hao-Bin Wang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Yin-Hu Wu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China.
| | - Li-Wei Luo
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Tong Yu
- School of Environmental and Municipal Engineering, Qingdao University of Technology, Qingdao 266000, PR China
| | - Ao Xu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China; Research Institute for Environmental Innovation (Suzhou), Tsinghua, Suzhou Jiangsu 215163, PR China
| | - Song Xue
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Gen-Qiang Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Xin-Ye Ni
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Lu Peng
- Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, PR China
| | - Zhuo Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Yun-Hong Wang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Xin Tong
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Yuan Bai
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Yu-Qing Xu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China; Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, PR China.
| |
Collapse
|
16
|
Bordbar MM, Sheini A, Hashemi P, Hajian A, Bagheri H. Disposable Paper-Based Biosensors for the Point-of-Care Detection of Hazardous Contaminations-A Review. BIOSENSORS 2021; 11:316. [PMID: 34562906 PMCID: PMC8464915 DOI: 10.3390/bios11090316] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 08/29/2021] [Accepted: 09/01/2021] [Indexed: 02/07/2023]
Abstract
The fast detection of trace amounts of hazardous contaminations can prevent serious damage to the environment. Paper-based sensors offer a new perspective on the world of analytical methods, overcoming previous limitations by fabricating a simple device with valuable benefits such as flexibility, biocompatibility, disposability, biodegradability, easy operation, large surface-to-volume ratio, and cost-effectiveness. Depending on the performance type, the device can be used to analyze the analyte in the liquid or vapor phase. For liquid samples, various structures (including a dipstick, as well as microfluidic and lateral flow) have been constructed. Paper-based 3D sensors are prepared by gluing and folding different layers of a piece of paper, being more user-friendly, due to the combination of several preparation methods, the integration of different sensor elements, and the connection between two methods of detection in a small set. Paper sensors can be used in chromatographic, electrochemical, and colorimetric processes, depending on the type of transducer. Additionally, in recent years, the applicability of these sensors has been investigated in various applications, such as food and water quality, environmental monitoring, disease diagnosis, and medical sciences. Here, we review the development (from 2010 to 2021) of paper methods in the field of the detection and determination of toxic substances.
Collapse
Affiliation(s)
- Mohammad Mahdi Bordbar
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran 19945, Iran;
| | - Azarmidokht Sheini
- Department of Mechanical Engineering, Shohadaye Hoveizeh Campus of Technology, Shahid Chamran University of Ahvaz, Dashte Azadegan 78986, Iran;
| | - Pegah Hashemi
- Research and Development Department, Farin Behbood Tashkhis Ltd., Tehran 16471, Iran;
| | - Ali Hajian
- Institute of Sensor and Actuator Systems, TU Wien, Gusshausstrasse 27-29, 1040 Vienna, Austria;
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran 19945, Iran;
| |
Collapse
|
17
|
Ajish JK, Abraham HM, Subramanian M, Kumar KSA. A Reusable Column Method Using Glycopolymer-Functionalized Resins for Capture-Detection of Proteins and Escherichia coli. Macromol Biosci 2020; 21:e2000342. [PMID: 33336880 DOI: 10.1002/mabi.202000342] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 11/27/2020] [Indexed: 11/08/2022]
Abstract
The use of glycopolymer-functionalized resins (Resin-Glc), as a solid support, in column mode for bacterial/protein capture and quantification is explored. The Resin-Glc is synthesized from commercially available chloromethylated polystyrene resin and glycopolymer, and is characterized by fourier transform infrared spectroscopy, thermogravimetry, and elemental analysis. The percentage of glycopolymer functionalized on Resin-Glc is accounted to be 5 wt%. The ability of Resin-Glc to selectively capture lectin, Concanavalin A, over Peanut Agglutinin, reversibly, is demonstrated for six cycles of experiments. The bacterial sequestration study using SYBR (Synergy Brands, Inc.) Green I tagged Escherichia coli/Staphylococcus aureus reveals the ability of Resin-Glc to selectively capture E. coli over S. aureus. The quantification of captured cells in the column is carried out by enzymatic colorimetric assay using methylumbelliferyl glucuronide as the substrate. The E. coli capture studies reveal a consistent capture efficiency of 105 CFU (Colony Forming Units) g-1 over six cycles. Studies with spiked tap water samples show satisfactory results for E. coli cell densities ranging from 102 to 107 CFU mL-1 . The method portrayed can serve as a basis for the development of a reusable solid support in capture and detection of proteins and bacteria.
Collapse
Affiliation(s)
- Juby K Ajish
- Radiation and Photochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
| | - Hephziba Maria Abraham
- Department of Polymer Science and Rubber Technology, Cochin University of Science and Technology, Kochi, 682020, India
| | - Mahesh Subramanian
- Bio-Organic Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
| | - K S Ajish Kumar
- Bio-Organic Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
| |
Collapse
|
18
|
Burklund A, Petryk JD, Hoopes PJ, Zhang JXJ. Microfluidic enrichment of bacteria coupled to contact-free lysis on a magnetic polymer surface for downstream molecular detection. BIOMICROFLUIDICS 2020; 14:034115. [PMID: 32642021 PMCID: PMC7316515 DOI: 10.1063/5.0011908] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 05/28/2020] [Indexed: 05/02/2023]
Abstract
We report on a microsystem that couples high-throughput bacterial immunomagnetic capture to contact-free cell lysis using an alternating current magnetic field (AMF) to enable downstream molecular characterization of bacterial nucleic acids. Traditional methods for cell lysis rely on either dilutive chemical methods, expensive biological reagents, or imprecise physical methods. We present a microchip with a magnetic polymer substrate (Mag-Polymer microchip), which enables highly controlled, on-chip heating of biological targets following exposure to an AMF. First, we present a theoretical framework for the quantitation of power generation for single-domain magnetic nanoparticles embedded in a polymer matrix. Next, we demonstrate successful bacterial DNA recovery by coupling (1) high-throughput, sensitive microfluidic immunomagnetic capture of bacteria to (2) on-chip, contact-free bacterial lysis using an AMF. The bacterial capture efficiency exceeded 76% at 50 ml/h at cell loads as low as ∼10 CFU/ml, and intact DNA was successfully recovered at starting bacterial concentrations as low as ∼1000 CFU/ml. Using the presented methodology, cell lysis becomes non-dilutive, temperature is precisely controlled, and potential contamination risks are eliminated. This workflow and substrate modification could be easily integrated in a range of micro-scale diagnostic systems for infectious disease.
Collapse
Affiliation(s)
- Alison Burklund
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755, USA
| | - James D. Petryk
- Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire 03755, USA
| | | | | |
Collapse
|
19
|
Khnouf R, Han C. Isotachophoresis-Enhanced Immunoassays: Challenges and opportunities. IEEE NANOTECHNOLOGY MAGAZINE 2020. [DOI: 10.1109/mnano.2020.2966028] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
20
|
Wang T, Yu C, Xie X. Microfluidics for Environmental Applications. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2020; 179:267-290. [PMID: 32440697 DOI: 10.1007/10_2020_128] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Microfluidic and lab-on-a-chip systems have become increasingly important tools across many research fields in recent years. As a result of their small size and precise flow control, as well as their ability to enable in situ process visualization, microfluidic systems are increasingly finding applications in environmental science and engineering. Broadly speaking, their main present applications within these fields include use as sensors for water contaminant analysis (e.g., heavy metals and organic pollutants), as tools for microorganism detection (e.g., virus and bacteria), and as platforms for the investigation of environment-related problems (e.g., bacteria electron transfer and biofilm formation). This chapter aims to review the applications of microfluidics in environmental science and engineering - with a particular focus on the foregoing topics. The advantages and limitations of microfluidics when compared to traditional methods are also surveyed, and several perspectives on the future of research and development into microfluidics for environmental applications are offered.
Collapse
Affiliation(s)
- Ting Wang
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Cecilia Yu
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Xing Xie
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
| |
Collapse
|
21
|
Jaywant SA, Arif KM. A Comprehensive Review of Microfluidic Water Quality Monitoring Sensors. SENSORS (BASEL, SWITZERLAND) 2019; 19:E4781. [PMID: 31684136 PMCID: PMC6864743 DOI: 10.3390/s19214781] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 10/29/2019] [Accepted: 10/31/2019] [Indexed: 12/20/2022]
Abstract
Water crisis is a global issue due to water contamination and extremely restricted sources of fresh water. Water contamination induces severe diseases which put human lives at risk. Hence, water quality monitoring has become a prime activity worldwide. The available monitoring procedures are inadequate as most of them require expensive instrumentation, longer processing time, tedious processes, and skilled lab technicians. Therefore, a portable, sensitive, and selective sensor with in situ and continuous water quality monitoring is the current necessity. In this context, microfluidics is the promising technology to fulfill this need due to its advantages such as faster reaction times, better process control, reduced waste generation, system compactness and parallelization, reduced cost, and disposability. This paper presents a review on the latest enhancements of microfluidic-based electrochemical and optical sensors for water quality monitoring and discusses the relative merits and shortcomings of the methods.
Collapse
Affiliation(s)
- Swapna A Jaywant
- Department of Mechanical and Electrical Engineering, SF&AT, Massey University, Auckland 0632, New Zealand.
| | - Khalid Mahmood Arif
- Department of Mechanical and Electrical Engineering, SF&AT, Massey University, Auckland 0632, New Zealand.
| |
Collapse
|
22
|
Hansen CB, Kerrouche A, Tatari K, Rasmussen A, Ryan T, Summersgill P, Desmulliez MPY, Bridle H, Albrechtsen HJ. Monitoring of drinking water quality using automated ATP quantification. J Microbiol Methods 2019; 165:105713. [PMID: 31476354 DOI: 10.1016/j.mimet.2019.105713] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 08/28/2019] [Accepted: 08/29/2019] [Indexed: 11/28/2022]
Abstract
A microfluidic based system was developed for automated online method for the rapid detection and monitoring of drinking water contamination utilising microbial Adrenosine-5'-Triphosphate (ATP) as a bacterial indicator. The system comprises a polymethyl methacrylate based microfluidic cartridge inserted into an enclosure incorporating the functions of fluid storage and delivery, lysis steps and real-time detection. Design, integration and operation of the resulting automated system are reported, including the lysis method, the design of the mixing circuit, the choices of flow rate, temperature and reagent amount. Calibration curves of both total and free ATP were demonstrated to be highly linear over a range from 2.5-5000 pg/mL with the limit of detection being lower than 2.5 pg/mL of total ATP. The system was trialled in a lab study with different types of water, with lysis efficiency being found to be strongly dependent upon water type. Further development is required before online implementation.
Collapse
Affiliation(s)
- C B Hansen
- Technical University of Denmark, Lyngby, Denmark
| | | | - K Tatari
- Technical University of Denmark, Lyngby, Denmark
| | - A Rasmussen
- Technical University of Denmark, Lyngby, Denmark
| | | | | | - M P Y Desmulliez
- Multi-Modal Sensing and Micro-Manipulation Centre (CAPTURE), Institute of Sensors, Signals and Systems (ISSS), Heriot-Watt University, Edinburgh, Scotland EH14 4AS, UK
| | - H Bridle
- Institute of Biological Chemistry, Biophysics and Bioengineering, Heriot-Watt University, Edinburgh, Scotland EH14 4AS, UK.
| | | |
Collapse
|
23
|
Gorgannezhad L, Stratton H, Nguyen NT. Microfluidic-Based Nucleic Acid Amplification Systems in Microbiology. MICROMACHINES 2019; 10:E408. [PMID: 31248141 PMCID: PMC6630468 DOI: 10.3390/mi10060408] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 06/14/2019] [Accepted: 06/17/2019] [Indexed: 02/07/2023]
Abstract
Rapid, sensitive, and selective bacterial detection is a hot topic, because the progress in this research area has had a broad range of applications. Novel and innovative strategies for detection and identification of bacterial nucleic acids are important for practical applications. Microfluidics is an emerging technology that only requires small amounts of liquid samples. Microfluidic devices allow for rapid advances in microbiology, enabling access to methods of amplifying nucleic acid molecules and overcoming difficulties faced by conventional. In this review, we summarize the recent progress in microfluidics-based polymerase chain reaction devices for the detection of nucleic acid biomarkers. The paper also discusses the recent development of isothermal nucleic acid amplification and droplet-based microfluidics devices. We discuss recent microfluidic techniques for sample preparation prior to the amplification process.
Collapse
Affiliation(s)
- Lena Gorgannezhad
- Queensland Micro- and Nanotechnology Centre, Nathan Campus, Griffith University, 170 Kessels Road, Brisbane QLD 4111, Australia.
- School of Environment and Science, Nathan Campus, Griffith University, 170 Kessels Road, Brisbane QLD 4111, Australia.
| | - Helen Stratton
- School of Environment and Science, Nathan Campus, Griffith University, 170 Kessels Road, Brisbane QLD 4111, Australia.
| | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology Centre, Nathan Campus, Griffith University, 170 Kessels Road, Brisbane QLD 4111, Australia.
| |
Collapse
|
24
|
Rapid On-Site Detection and Quantification of Foodborne Pathogens Using Microfluidic Devices. Methods Mol Biol 2019. [PMID: 30580399 DOI: 10.1007/978-1-4939-9000-9_5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
The potential for foodborne infectious disease outbreaks has increased not only on a local scale but also on a regional and international scale. Simple, rapid, and accurate methods to enumerate pathogenic bacteria in food and drink are required to prevent the spread of these bacteria. Here, I describe applications of a microfluidic device for on-chip fluorescent staining and semiautomated counting of target bacteria in food samples.
Collapse
|
25
|
Brainard J, Hammer CC, Bouzid M, Hunter PR. Emerging pathogens and deliberate attacks on European water supplies: a scenario planning workshop. JOURNAL OF WATER AND HEALTH 2019; 17:463-476. [PMID: 31095521 DOI: 10.2166/wh.2019.248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Microbiological contamination of drinking water supplies is an ever-present concern for water utility managers. Most such threats are routine, well-recognised and described. Therefore, they can usually be prevented using standard protection measures. Incidents involving emerging pathogens and malicious attacks are inherently less predictable. In a multi-stage process over one day, participants with backgrounds in microbiology, medicine, infrastructure, data analysis, environmental or public health and facility management developed qualitative scenarios on potential threats posed by either an emergent pathogen in or a microbiological attack on drinking water supplies in a European country. Participants were guided via structured activities to identify key factors that would impact the magnitude and severity of such an emergency. Plausible variant states for each key factor were determined, and participants constructed sequences of events to create scenario outlines. Five scenarios in outline form are reported which incorporate genuine possible future events as well as pathogens of international concern. Common features that would exacerbate all scenarios were under-investment in public services, inadequate water quality testing, and monitoring and lack of resources to keep water supplies safe. Participant evaluation of their scenario planning experience was broadly very positive and the scenario planning process was received as credible and relevant.
Collapse
Affiliation(s)
- Julii Brainard
- Norwich Medical School, University of East Anglia, Norwich NR4 7TJ, Norfolk, UK E-mail:
| | - Charlotte C Hammer
- Norwich Medical School, University of East Anglia, Norwich NR4 7TJ, Norfolk, UK E-mail:
| | - Maha Bouzid
- Norwich Medical School, University of East Anglia, Norwich NR4 7TJ, Norfolk, UK E-mail:
| | - Paul R Hunter
- Norwich Medical School, University of East Anglia, Norwich NR4 7TJ, Norfolk, UK E-mail:
| |
Collapse
|
26
|
Chylewska A, Ogryzek M, Makowski M. Modern Approach to Medical Diagnostics - the Use of Separation Techniques in Microorganisms Detection. Curr Med Chem 2019; 26:121-165. [DOI: 10.2174/0929867324666171023164813] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2016] [Revised: 04/20/2017] [Accepted: 05/20/2016] [Indexed: 11/22/2022]
Abstract
Background:Analytical chemistry and biotechnology as an interdisciplinary fields of science have been developed during many years and are experiencing significant growth, to cover a wide range of microorganisms separation techniques and methods, utilized for medical therapeutic and diagnostic purposes. Currently scientific reports contribute by introducing electrophoretical and immunological methods and formation of devices applied in food protection (avoiding epidemiological diseases) and healthcare (safety ensuring in hospitals).Methods:Electrophoretic as well as nucleic-acid-based or specific immunological methods have contributed tremendously to the advance of analyses in recent three decades, particularly in relation to bacteria, viruses and fungi identifications, especially in medical in vitro diagnostics, as well as in environmental or food protection.Results:The paper presents the pathogen detection competitiveness of these methods against conventional ones, which are still too time consuming and also labor intensive. The review is presented in several parts following the current trends in improved pathogens separation and detection methods and their subsequent use in medical diagnosis.Discussion:Part one, consists of elemental knowledge about microorganisms as an introduction to their characterization: descriptions of divisions, sizes, membranes (cells) components. Second section includes the development, new technological and practical solution descriptions used in electrophoretical procedures during microbes analyses, with special attention paid to bio-samples analyses like blood, urine, lymph or wastewater. Third part covers biomolecular areas that have created a basis needed to identify the progress, limitations and challenges of nucleic-acid-based and immunological techniques discussed to emphasize the advantages of new separative techniques in selective fractionating of microorganisms.
Collapse
Affiliation(s)
- Agnieszka Chylewska
- Laboratory of Intermolecular Interactions, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80- 308 Gdansk, Poland
| | - Małgorzata Ogryzek
- Laboratory of Intermolecular Interactions, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80- 308 Gdansk, Poland
| | - Mariusz Makowski
- Laboratory of Intermolecular Interactions, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80- 308 Gdansk, Poland
| |
Collapse
|
27
|
Zhang Y, Xu CQ, Guo T, Hong L. An automated bacterial concentration and recovery system for pre-enrichment required in rapid Escherichia coli detection. Sci Rep 2018; 8:17808. [PMID: 30546076 PMCID: PMC6292886 DOI: 10.1038/s41598-018-35970-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Accepted: 11/09/2018] [Indexed: 12/18/2022] Open
Abstract
One of the biggest challenges in rapid low concentration bacterial detection is the pre-concentration or pre-enrichment, which aims to increase bacteria concentration and reduce sample volume for easy bacterial detection. In practical bacterial detection, large-volume water samples with a pathogenic bacterial concentration of less than 1 CFU/mL have to be tested rapidly. The reported biosensors either have insufficient detection limit or have limited capability of handling a sufficiently large water sample. Therefore, a high-performance automated pre-enrichment process is strongly demanded in rapid practical bacterial detection. In this paper, a practical high performance automated bacterial concentration and recovery system (ABCRS) based on the combination of a ceramic membrane and tangential flow filtration technique was presented with short processing time (less than one hour), low pre-enrichment limit (≤0.005 CFU/mL), high concentration ratio (≥ 500), high recovery efficiency (~ 90%), and small final retentate volume (≤ 5 mL).
Collapse
Affiliation(s)
- Yushan Zhang
- Faculty of Engineering, McMaster University, Hamilton, Canada
| | - Chang-Qing Xu
- Faculty of Engineering, McMaster University, Hamilton, Canada.
| | - Tianyi Guo
- Forsee Instruments Ltd., Hamilton, Canada
| | - Lingcheng Hong
- Jiangsu Delin Environmental Protection Technology Co., Ltd., Jiangsu, China
| |
Collapse
|
28
|
Lin X, Huang X, Zhu Y, Urmann K, Xie X, Hoffmann MR. Asymmetric Membrane for Digital Detection of Single Bacteria in Milliliters of Complex Water Samples. ACS NANO 2018; 12:10281-10290. [PMID: 30211534 PMCID: PMC6202633 DOI: 10.1021/acsnano.8b05384] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Accepted: 09/13/2018] [Indexed: 05/22/2023]
Abstract
In this work, we introduce an asymmetric membrane as a simple and robust nanofluidic platform for digital detection of single pathogenic bacteria directly in 10 mL of unprocessed environmental water samples. The asymmetric membrane, consisting of uniform micropores on one side and a high density of vertically aligned nanochannels on the other side, was prepared within 1 min by a facile method. The single membrane covers all the processing steps from sample concentration, purification, and partition to final digital loop-mediated isothermal amplification (LAMP). By simple filtration, bacteria were enriched and partitioned inside the micropores, while inhibitors typically found in the environmental samples ( i.e., proteins, heavy metals, and organics) were washed away through the nanochannels. Meanwhile, large particles, indigenous plankton, and positively charged pollutants in the samples were excluded by using a sacrificial membrane stacked on top. After initial filtration, modified LAMP reagents, including NaF and lysozyme, were loaded onto the membrane. Each pore in the asymmetric membrane functioned as an individual nanoreactor for selective, rapid, and efficient isothermal amplification of single bacteria, generating a bright fluorescence for direct counting. Even though high levels of inhibitors were present, absolute quantification of Escherichia coli and Salmonella directly in an unprocessed environmental sample (seawater and pond water) was achieved within 1 h, with sensitivity down to single cell and a dynamic range of 0.3-10000 cells/mL. The simple and low-cost analysis platform described herein has an enormous potential for the detection of pathogens, exosomes, stem cells, and viruses as well as single-cell heterogeneity analysis in environmental, food, and clinical research.
Collapse
Affiliation(s)
- Xingyu Lin
- Linde
+ Robinson Laboratories, California Institute
of Technology, Pasadena, California 91125, United States
| | - Xiao Huang
- Linde
+ Robinson Laboratories, California Institute
of Technology, Pasadena, California 91125, United States
| | - Yanzhe Zhu
- Linde
+ Robinson Laboratories, California Institute
of Technology, Pasadena, California 91125, United States
| | - Katharina Urmann
- Linde
+ Robinson Laboratories, California Institute
of Technology, Pasadena, California 91125, United States
| | - Xing Xie
- Linde
+ Robinson Laboratories, California Institute
of Technology, Pasadena, California 91125, United States
- School
of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Michael R. Hoffmann
- Linde
+ Robinson Laboratories, California Institute
of Technology, Pasadena, California 91125, United States
- E-mail:
| |
Collapse
|
29
|
Fernandes AC, Gernaey KV, Krühne U. “Connecting worlds – a view on microfluidics for a wider application”. Biotechnol Adv 2018; 36:1341-1366. [DOI: 10.1016/j.biotechadv.2018.05.001] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 04/30/2018] [Accepted: 05/01/2018] [Indexed: 01/19/2023]
|
30
|
Wang J, Yu X, Wang Y, Pan X, Li D. Detection of viability of micro-algae cells by optofluidic hologram pattern. BIOMICROFLUIDICS 2018; 12:024111. [PMID: 29657655 PMCID: PMC5876039 DOI: 10.1063/1.5021179] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Accepted: 03/16/2018] [Indexed: 06/08/2023]
Abstract
A rapid detection of micro-algae activity is critical for analysis of ship ballast water. A new method for detecting micro-algae activity based on lens-free optofluidic holographic imaging is presented in this paper. A compact lens-free optofluidic holographic imaging device was developed. This device is mainly composed of a light source, a small through-hole, a light propagation module, a microfluidic chip, and an image acquisition and processing module. The excited light from the light source passes through a small hole to reach the surface of the micro-algae cells in the microfluidic chip, and a holographic image is formed by the diffraction light of surface of micro-algae cells. The relation between the characteristics in the hologram pattern and the activity of micro-algae cells was investigated by using this device. The characteristics of the hologram pattern were extracted to represent the activity of micro-algae cells. To demonstrate the accuracy of the presented method and device, four species of micro-algae cells were employed as the test samples and the comparison experiments between the alive and dead cells of four species of micro-algae were conducted. The results show that the developed method and device can determine live/dead microalgae cells accurately.
Collapse
Affiliation(s)
- Junsheng Wang
- College of Information and Science Technology, Dalian Maritime University, Dalian 116026, China
| | - Xiaomei Yu
- College of Information and Science Technology, Dalian Maritime University, Dalian 116026, China
| | - Yanjuan Wang
- College of Information and Science Technology, Dalian Maritime University, Dalian 116026, China
| | - Xinxiang Pan
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China
| | - Dongqing Li
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario N2L3G1, Canada
| |
Collapse
|
31
|
Zulkifli SN, Rahim HA, Lau WJ. Detection of contaminants in water supply: A review on state-of-the-art monitoring technologies and their applications. SENSORS AND ACTUATORS. B, CHEMICAL 2018; 255:2657-2689. [PMID: 32288249 PMCID: PMC7126548 DOI: 10.1016/j.snb.2017.09.078] [Citation(s) in RCA: 92] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Revised: 08/22/2017] [Accepted: 09/13/2017] [Indexed: 05/12/2023]
Abstract
Water monitoring technologies are widely used for contaminants detection in wide variety of water ecology applications such as water treatment plant and water distribution system. A tremendous amount of research has been conducted over the past decades to develop robust and efficient techniques of contaminants detection with minimum operating cost and energy. Recent developments in spectroscopic techniques and biosensor approach have improved the detection sensitivities, quantitatively and qualitatively. The availability of in-situ measurements and multiple detection analyses has expanded the water monitoring applications in various advanced techniques including successful establishment in hand-held sensing devices which improves portability in real-time basis for the detection of contaminant, such as microorganisms, pesticides, heavy metal ions, inorganic and organic components. This paper intends to review the developments in water quality monitoring technologies for the detection of biological and chemical contaminants in accordance with instrumental limitations. Particularly, this review focuses on the most recently developed techniques for water contaminant detection applications. Several recommendations and prospective views on the developments in water quality assessments will also be included.
Collapse
Affiliation(s)
| | - Herlina Abdul Rahim
- Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
| | - Woei-Jye Lau
- Advanced Membrane Technology Research Centre (AMTEC), Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
| |
Collapse
|
32
|
Ha NS, Sadeghi S, van Dam RM. Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals. MICROMACHINES 2017; 8:E337. [PMID: 30400527 PMCID: PMC6190332 DOI: 10.3390/mi8110337] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 11/08/2017] [Accepted: 11/18/2017] [Indexed: 01/18/2023]
Abstract
Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET) or single photon emission tomography (SPECT) scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers) must undergo quality control (QC) testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i) pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii) radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a discussion of efforts to directly miniaturize the test or examples in the literature that could be implemented for miniaturized QC testing.
Collapse
Affiliation(s)
- Noel S Ha
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California Los Angeles, Los Angeles, CA 90095, USA.
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA.
| | - Saman Sadeghi
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA.
| | - R Michael van Dam
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California Los Angeles, Los Angeles, CA 90095, USA.
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA.
| |
Collapse
|
33
|
Sesen M, Alan T, Neild A. Droplet control technologies for microfluidic high throughput screening (μHTS). LAB ON A CHIP 2017. [PMID: 28631799 DOI: 10.1039/c7lc00005g] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The transition from micro well plate and robotics based high throughput screening (HTS) to chip based screening has already started. This transition promises reduced droplet volumes thereby decreasing the amount of fluids used in these studies. Moreover, it significantly boosts throughput allowing screening to keep pace with the overwhelming number of molecular targets being discovered. In this review, we analyse state-of-the-art droplet control technologies that exhibit potential to be used in this new generation of screening devices. Since these systems are enclosed and usually planar, even some of the straightforward methods used in traditional HTS such as pipetting and reading can prove challenging to replicate in microfluidic high throughput screening (μHTS). We critically review the technologies developed for this purpose in depth, describing the underlying physics and discussing the future outlooks.
Collapse
Affiliation(s)
- Muhsincan Sesen
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia.
| | | | | |
Collapse
|
34
|
Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system. Sci Rep 2017; 7:3092. [PMID: 28596545 PMCID: PMC5465085 DOI: 10.1038/s41598-017-03293-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 04/26/2017] [Indexed: 11/09/2022] Open
Abstract
Legionnaires' disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 104 cells/ml, but lower numbers of L. pneumophila cells (101 to 103 cells/ml) could be detected following concentration of 0.5-3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.
Collapse
|
35
|
Guo R, McGoverin C, Swift S, Vanholsbeeck F. A rapid and low-cost estimation of bacteria counts in solution using fluorescence spectroscopy. Anal Bioanal Chem 2017; 409:3959-3967. [PMID: 28389919 PMCID: PMC5437196 DOI: 10.1007/s00216-017-0347-1] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Revised: 03/08/2017] [Accepted: 03/28/2017] [Indexed: 11/15/2022]
Abstract
The fluorescence spectrum of bacterially bound acridine orange (AO) was investigated to evaluate its use for the rapid enumeration of bacteria. Escherichia coli ATCC 25922 samples were stained with 2 × 10-2, 2 × 10-3 or 2 × 10-4% w/v AO, followed by 3, 2 or 0 washing cycles, respectively, and fluorescence spectra were recorded using a fibre-based spectroscopic system. Independent component analysis was used to analyse the spectral datasets for each staining method. Bacterial concentration order of magnitude classification models were calculated using independent component weights. The relationship between fluorescence intensity of bound AO and bacterial concentration was not linear. However, the spectral signals collected for AO stain concentration-bacterial concentration pairs were reproducible and unique enough to enable classification of samples. When above 105 CFU ml-1, it was possible to rapidly determine what the order of magnitude of bacterial concentration of a sample was using a combination of two of the sample preparation methods. A relatively inexpensive (around US$10 per test) rapid method (within 25 min of sampling) for enumeration of bacteria by order of magnitude will reduce the time and cost of microbiological tests requiring gross concentration information. Graphical Abstract Fluorescence spectra of bacterially bound acridine orange (AO) were used for the rapid enumeration of bacteria. Order of magnitude bacterial concentration classification models were calculated using independent components analysis of these fluorescence spectra. When above 105 CFU ml-1, it was possible to rapidly determine the order of magnitude of bacterial concentration of a sample using a combination of two sample preparation methods.
Collapse
Affiliation(s)
- Rachel Guo
- The Dodd-Walls Centre for Photonic and Quantum Technologies, Department of Physics, The University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand
| | - Cushla McGoverin
- The Dodd-Walls Centre for Photonic and Quantum Technologies, Department of Physics, The University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand
| | - Simon Swift
- Department of Molecular Medicine and Pathology, The University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand
| | - Frederique Vanholsbeeck
- The Dodd-Walls Centre for Photonic and Quantum Technologies, Department of Physics, The University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand.
| |
Collapse
|
36
|
Fernandez RE, Rohani A, Farmehini V, Swami NS. Review: Microbial analysis in dielectrophoretic microfluidic systems. Anal Chim Acta 2017; 966:11-33. [PMID: 28372723 PMCID: PMC5424535 DOI: 10.1016/j.aca.2017.02.024] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 02/03/2017] [Accepted: 02/20/2017] [Indexed: 12/13/2022]
Abstract
Infections caused by various known and emerging pathogenic microorganisms, including antibiotic-resistant strains, are a major threat to global health and well-being. This highlights the urgent need for detection systems for microbial identification, quantification and characterization towards assessing infections, prescribing therapies and understanding the dynamic cellular modifications. Current state-of-the-art microbial detection systems exhibit a trade-off between sensitivity and assay time, which could be alleviated by selective and label-free microbial capture onto the sensor surface from dilute samples. AC electrokinetic methods, such as dielectrophoresis, enable frequency-selective capture of viable microbial cells and spores due to polarization based on their distinguishing size, shape and sub-cellular compositional characteristics, for downstream coupling to various detection modalities. Following elucidation of the polarization mechanisms that distinguish bacterial cells from each other, as well as from mammalian cells, this review compares the microfluidic platforms for dielectrophoretic manipulation of microbials and their coupling to various detection modalities, including immuno-capture, impedance measurement, Raman spectroscopy and nucleic acid amplification methods, as well as for phenotypic assessment of microbial viability and antibiotic susceptibility. Based on the urgent need within point-of-care diagnostics towards reducing assay times and enhancing capture of the target organism, as well as the emerging interest in isolating intact microbials based on their phenotype and subcellular features, we envision widespread adoption of these label-free and selective electrokinetic techniques.
Collapse
Affiliation(s)
- Renny E Fernandez
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA 22904, USA
| | - Ali Rohani
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA 22904, USA
| | - Vahid Farmehini
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA 22904, USA
| | - Nathan S Swami
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA 22904, USA.
| |
Collapse
|
37
|
Jimenez M, Miller B, Bridle HL. Efficient separation of small microparticles at high flowrates using spiral channels: Application to waterborne pathogens. Chem Eng Sci 2017. [DOI: 10.1016/j.ces.2015.08.042] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
38
|
Burlage RS, Tillmann J. Biosensors of bacterial cells. J Microbiol Methods 2016; 138:2-11. [PMID: 28040457 DOI: 10.1016/j.mimet.2016.12.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Revised: 12/24/2016] [Accepted: 12/24/2016] [Indexed: 10/20/2022]
Abstract
Biosensors are devices which utilize both an electrical component (transducer) and a biological component to study an environment. They are typically used to examine biological structures, organisms and processes. The field of biosensors has now become so large and varied that the technology can often seem impenetrable. Yet the principles which underlie the technology are uncomplicated, even if the details of the mechanisms are elusive. In this review we confine our analysis to relatively current advancements in biosensors for the detection of whole bacterial cells. This includes biosensors which rely on an added labeled component and biosensors which do not have a labeled component and instead detect the binding event or bound structure on the transducer. Methods to concentrate the bacteria prior to biosensor analysis are also described. The variety of biosensor types and their actual and potential uses are described.
Collapse
Affiliation(s)
- Robert S Burlage
- Department of Pharmaceutical and Administrative Science, Concordia University School of Pharmacy, 12800 N. Lake Shore Dr., Mequon, WI 53097, United States.
| | - Joshua Tillmann
- Department of Pharmaceutical and Administrative Science, Concordia University School of Pharmacy, 12800 N. Lake Shore Dr., Mequon, WI 53097, United States
| |
Collapse
|
39
|
Jimenez M, Bridle H. Microfluidics for effective concentration and sorting of waterborne protozoan pathogens. J Microbiol Methods 2016; 126:8-11. [PMID: 27074367 DOI: 10.1016/j.mimet.2016.04.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2016] [Revised: 04/07/2016] [Accepted: 04/07/2016] [Indexed: 11/24/2022]
Abstract
We report on an inertial focussing based microfluidics technology for concentrating waterborne protozoa, achieving a 96% recovery rate of Cryptosporidium parvum and 86% for Giardia lamblia at a throughput (mL/min) capable of replacing centrifugation. The approach can easily be extended to other parasites and also bacteria.
Collapse
Affiliation(s)
- M Jimenez
- Institute of Biological Chemistry, Biophysics and Bioengineering, Heriot-Watt University, Riccarton, Scotland, Edinburgh EH14 4AS, United Kingdom.
| | - H Bridle
- Institute of Biological Chemistry, Biophysics and Bioengineering, Heriot-Watt University, Riccarton, Scotland, Edinburgh EH14 4AS, United Kingdom
| |
Collapse
|
40
|
Juang YJ, Chang JS. Applications of microfluidics in microalgae biotechnology: A review. Biotechnol J 2016; 11:327-35. [DOI: 10.1002/biot.201500278] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Revised: 10/29/2015] [Accepted: 12/25/2015] [Indexed: 11/08/2022]
Affiliation(s)
- Yi-Je Juang
- Department of Chemical Engineering; National Cheng Kung University; Tainan Taiwan
| | - Jo-Shu Chang
- Department of Chemical Engineering; National Cheng Kung University; Tainan Taiwan
| |
Collapse
|
41
|
Abstract
A dynamic development of methodologies of analytical flow injection measurements during four decades since their invention has reinforced the solid position of flow analysis in the arsenal of techniques and instrumentation of contemporary chemical analysis.
Collapse
Affiliation(s)
- Marek Trojanowicz
- Laboratory of Nuclear Analytical Methods
- Institute of Nuclear Chemistry and Technology
- 03-195 Warsaw
- Poland
- Department of Chemistry
| | - Kamila Kołacińska
- Laboratory of Nuclear Analytical Methods
- Institute of Nuclear Chemistry and Technology
- 03-195 Warsaw
- Poland
| |
Collapse
|
42
|
Esfahani MMN, Tarn MD, Choudhury TA, Hewitt LC, Mayo AJ, Rubin TA, Waller MR, Christensen MG, Dawson A, Pamme N. Lab-on-a-chip workshop activities for secondary school students. BIOMICROFLUIDICS 2016; 10:011301. [PMID: 26865902 PMCID: PMC4744233 DOI: 10.1063/1.4940884] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Accepted: 01/09/2016] [Indexed: 05/16/2023]
Abstract
The ability to engage and inspire younger generations in novel areas of science is important for bringing new researchers into a burgeoning field, such as lab-on-a-chip. We recently held a lab-on-a-chip workshop for secondary school students, for which we developed a number of hands-on activities that explained various aspects of microfluidic technology, including fabrication (milling and moulding of microfluidic devices, and wax printing of microfluidic paper-based analytical devices, so-called μPADs), flow regimes (gradient formation via diffusive mixing), and applications (tissue analysis and μPADs). Questionnaires completed by the students indicated that they found the workshop both interesting and informative, with all activities proving successful, while providing feedback that could be incorporated into later iterations of the event.
Collapse
Affiliation(s)
| | - Mark D Tarn
- Department of Chemistry, University of Hull , Cottingham Road, Hull HU6 7RX, United Kingdom
| | - Tahmina A Choudhury
- Department of Chemistry, University of Hull , Cottingham Road, Hull HU6 7RX, United Kingdom
| | - Laura C Hewitt
- Department of Chemistry, University of Hull , Cottingham Road, Hull HU6 7RX, United Kingdom
| | - Ashley J Mayo
- Department of Chemistry, University of Hull , Cottingham Road, Hull HU6 7RX, United Kingdom
| | - Theodore A Rubin
- Department of Chemistry, University of Hull , Cottingham Road, Hull HU6 7RX, United Kingdom
| | - Mathew R Waller
- Department of Chemistry, University of Hull , Cottingham Road, Hull HU6 7RX, United Kingdom
| | - Martin G Christensen
- Department of Chemistry, University of Hull , Cottingham Road, Hull HU6 7RX, United Kingdom
| | - Amy Dawson
- School of Biological, Biomedical and Environmental Sciences, University of Hull , Cottingham Road, Hull HU6 7RX, United Kingdom
| | - Nicole Pamme
- Department of Chemistry, University of Hull , Cottingham Road, Hull HU6 7RX, United Kingdom
| |
Collapse
|
43
|
Faustino V, Catarino SO, Lima R, Minas G. Biomedical microfluidic devices by using low-cost fabrication techniques: A review. J Biomech 2015; 49:2280-2292. [PMID: 26671220 DOI: 10.1016/j.jbiomech.2015.11.031] [Citation(s) in RCA: 153] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2015] [Accepted: 11/11/2015] [Indexed: 12/23/2022]
Abstract
One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made to develop low-cost alternatives for the fabrication of microstructures, avoiding the use of cleanroom facilities. Recently, low-cost techniques without cleanroom facilities that feature aspect ratios more than 20, for fabricating those SU-8 moulds have been gaining popularity among biomedical research community. In those techniques, Ultraviolet (UV) exposure equipment, commonly used in the Printed Circuit Board (PCB) industry, replaces the more expensive and less available Mask Aligner that has been used in the last 15 years for SU-8 patterning. Alternatively, non-lithographic low-cost techniques, due to their ability for large-scale production, have increased the interest of the industrial and research community to develop simple, rapid and low-cost microfluidic structures. These alternative techniques include Print and Peel methods (PAP), laserjet, solid ink, cutting plotters or micromilling, that use equipment available in almost all laboratories and offices. An example is the xurography technique that uses a cutting plotter machine and adhesive vinyl films to generate the master moulds to fabricate microfluidic channels. In this review, we present a selection of the most recent lithographic and non-lithographic low-cost techniques to fabricate microfluidic structures, focused on the features and limitations of each technique. Only microfabrication methods that do not require the use of cleanrooms are considered. Additionally, potential applications of these microfluidic devices in biomedical engineering are presented with some illustrative examples.
Collapse
Affiliation(s)
- Vera Faustino
- MEMS-UMinho Research Unit, Universidade do Minho, DEI, Campus de Azurém, 4800-058 Guimarães, Portugal; Transport Phenomena Research Center, Department of Chemical Engineering, Engineering Faculty, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.
| | - Susana O Catarino
- MEMS-UMinho Research Unit, Universidade do Minho, DEI, Campus de Azurém, 4800-058 Guimarães, Portugal; Transport Phenomena Research Center, Department of Chemical Engineering, Engineering Faculty, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.
| | - Rui Lima
- MEtRiCS, Department of Mechanical Engineering, Minho University, Campus de Azurém, 4800-058 Guimarães, Portugal; Transport Phenomena Research Center, Department of Chemical Engineering, Engineering Faculty, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolonia, 5301-857 Bragança, Portugal.
| | - Graça Minas
- MEMS-UMinho Research Unit, Universidade do Minho, DEI, Campus de Azurém, 4800-058 Guimarães, Portugal.
| |
Collapse
|
44
|
Fong EJ, Huang C, Hamilton J, Benett WJ, Bora M, Burklund A, Metz TR, Shusteff M. A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice. J Vis Exp 2015. [PMID: 26651055 PMCID: PMC4692749 DOI: 10.3791/53051] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
A major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15-1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection, system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.
Collapse
Affiliation(s)
- Erika J Fong
- Materials Engineering Division, Lawrence Livermore National Laboratory; Department of Biomedical Engineering, Boston University
| | - Chao Huang
- Materials Engineering Division, Lawrence Livermore National Laboratory
| | - Julie Hamilton
- Materials Engineering Division, Lawrence Livermore National Laboratory
| | - William J Benett
- Materials Engineering Division, Lawrence Livermore National Laboratory
| | - Mihail Bora
- Materials Engineering Division, Lawrence Livermore National Laboratory
| | - Alison Burklund
- Materials Engineering Division, Lawrence Livermore National Laboratory
| | - Thomas R Metz
- Materials Engineering Division, Lawrence Livermore National Laboratory
| | - Maxim Shusteff
- Materials Engineering Division, Lawrence Livermore National Laboratory;
| |
Collapse
|
45
|
Integrated Microfluidic Nucleic Acid Isolation, Isothermal Amplification, and Amplicon Quantification. MICROARRAYS 2015; 4:474-89. [PMID: 27600235 PMCID: PMC4996405 DOI: 10.3390/microarrays4040474] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Revised: 10/02/2015] [Accepted: 10/10/2015] [Indexed: 02/06/2023]
Abstract
Microfluidic components and systems for rapid (<60 min), low-cost, convenient, field-deployable sequence-specific nucleic acid-based amplification tests (NAATs) are described. A microfluidic point-of-care (POC) diagnostics test to quantify HIV viral load from blood samples serves as a representative and instructive example to discuss the technical issues and capabilities of “lab on a chip” NAAT devices. A portable, miniaturized POC NAAT with performance comparable to conventional PCR (polymerase-chain reaction)-based tests in clinical laboratories can be realized with a disposable, palm-sized, plastic microfluidic chip in which: (1) nucleic acids (NAs) are extracted from relatively large (~mL) volume sample lysates using an embedded porous silica glass fiber or cellulose binding phase (“membrane”) to capture sample NAs in a flow-through, filtration mode; (2) NAs captured on the membrane are isothermally (~65 °C) amplified; (3) amplicon production is monitored by real-time fluorescence detection, such as with a smartphone CCD camera serving as a low-cost detector; and (4) paraffin-encapsulated, lyophilized reagents for temperature-activated release are pre-stored in the chip. Limits of Detection (LOD) better than 103 virons/sample can be achieved. A modified chip with conduits hosting a diffusion-mode amplification process provides a simple visual indicator to readily quantify sample NA template. In addition, a companion microfluidic device for extracting plasma from whole blood without a centrifuge, generating cell-free plasma for chip-based molecular diagnostics, is described. Extensions to a myriad of related applications including, for example, food testing, cancer screening, and insect genotyping are briefly surveyed.
Collapse
|
46
|
Fine-Scale Spatial Heterogeneity in the Distribution of Waterborne Protozoa in a Drinking Water Reservoir. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2015; 12:11910-28. [PMID: 26404350 PMCID: PMC4586715 DOI: 10.3390/ijerph120911910] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Accepted: 09/15/2015] [Indexed: 01/31/2023]
Abstract
Background: The occurrence of faecal pathogens in drinking water resources constitutes a threat to the supply of safe drinking water, even in industrialized nations. To efficiently assess and monitor the risk posed by these pathogens, sampling deserves careful design, based on preliminary knowledge on their distribution dynamics in water. For the protozoan pathogens Cryptosporidium and Giardia, only little is known about their spatial distribution within drinking water supplies, especially at fine scale. Methods: Two-dimensional distribution maps were generated by sampling cross-sections at meter resolution in two different zones of a drinking water reservoir. Samples were analysed for protozoan pathogens as well as for E. coli, turbidity and physico-chemical parameters. Results: Parasites displayed heterogeneous distribution patterns, as reflected by significant (oo)cyst density gradients along reservoir depth. Spatial correlations between parasites and E. coli were observed near the reservoir inlet but were absent in the downstream lacustrine zone. Measurements of surface and subsurface flow velocities suggest a role of local hydrodynamics on these spatial patterns. Conclusion: This fine-scale spatial study emphasizes the importance of sampling design (site, depth and position on the reservoir) for the acquisition of representative parasite data and for optimization of microbial risk assessment and monitoring. Such spatial information should prove useful to the modelling of pathogen transport dynamics in drinking water supplies.
Collapse
|
47
|
Megasonic sonication for cost-effective and automatable elution of Cryptosporidium from filters and membranes. J Microbiol Methods 2015; 118:123-7. [PMID: 26363087 DOI: 10.1016/j.mimet.2015.09.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2015] [Revised: 09/03/2015] [Accepted: 09/03/2015] [Indexed: 11/21/2022]
Abstract
Sample processing is a highly challenging stage in the monitoring of waterborne pathogens. This step is time-consuming, requires highly trained technicians and often results in low recovery rates of pathogens. In the UK but also in other parts of the world, Cryptosporidium is the only pathogen directly tested for in routine operational monitoring. The traditional sampling process involves the filtration of 1000L of water, semi-automated elution of the filters and membranes with recovery rates of about 30-40% typically. This paper explores the use of megasonic sonication in an attempt to increase recovery rates and reduce both the time required for processing and the number of labour-intensive steps. Results demonstrate that megasonic energy assisted elution is equally effective as the traditional manual process in terms of recovery rates. Major advantages are however offered in terms of reduction of the elution volume enabling the current centrifugation stage to be avoided. This saves time, equipment and staff costs and critically removes the step in the process that would be most challenging to automate, paving the way thereby for highly effective automated solutions to pathogens monitoring.
Collapse
|
48
|
Jensen CD, Müeller C. Predictor–Response Analysis of Fiber Optic Enzymatic Biosensors Constructed with Nonmodified E. coli BL21 (DE3) pGELAF+ Sensing 1,2-Dichloroethane. Appl Biochem Biotechnol 2015; 176:987-98. [DOI: 10.1007/s12010-015-1623-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Accepted: 04/06/2015] [Indexed: 11/27/2022]
|
49
|
Jimenez M, Bridle HL. Angry pathogens, how to get rid of them: introducing microfluidics for waterborne pathogen separation to children. LAB ON A CHIP 2015; 15:947-57. [PMID: 25435144 DOI: 10.1039/c4lc00944d] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The purpose of this paper is to present a new approach for introducing to a non-scientific audience a major public health issue: access to safe drinking water. Access to safe drinking water is a privilege in developed countries and an urgent need in the third world, which implies always more efficient and reliable engineering tools to be developed. As a major global challenge it is important to make children aware of this problem for understanding (i) what safe drinking water is, (ii) how ingenious techniques are developed for this purpose and (iii) the role of microfluidics in this area. This paper focuses on different microfluidic-based techniques to separate and detect pathogens in drinking water that have been adapted to be performed by a young audience in a simplified, recreational and interactive way.
Collapse
Affiliation(s)
- Melanie Jimenez
- Heriot-Watt University, Microfluidic Biotech Group, Institute of Biological Chemistry, Biophysics and Bioengineering (IB3), Riccarton, Edinburgh, UK.
| | | |
Collapse
|
50
|
|