1
|
Akiyama Y, Sherwood N. Systematic review of biomarker findings from clinical studies of electronic cigarettes and heated tobacco products. Toxicol Rep 2021; 8:282-294. [PMID: 33552927 PMCID: PMC7850959 DOI: 10.1016/j.toxrep.2021.01.014] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 01/21/2021] [Accepted: 01/21/2021] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Worldwide adoption of electronic cigarettes (e-cigarettes) and heated tobacco products (HTPs) has increased exponentially over the past decade. These products have been proposed as non-combustible alternatives to traditional tobacco products such as cigarettes and may thus reduce the negative health consequences associated with tobacco smoke. However, the overall health impact and safety of using these products remains unclear. This review seeks to provide an updated summary of available evidence on changes to levels of tobacco-related biomarkers to aid the overall assessment of the consequences of using e-cigarettes and HTPs. METHODS A systematic review was conducted through major databases (Medline/PubMed, Scopus, EMBASE) searching for articles directly comparing biomarker levels in humans using e-cigarettes or HTPs and those using combustible cigarettes. We included peer reviewed articles with comparative or longitudinal design and extracted key information for our purpose (type of population, demographics, biomarkers measurements, and health effects). An initial qualitative analysis was performed followed by a summary of findings. RESULTS A total of 44 studies were included from initial citations. The vast majority of the literature reported reductions in levels of biomarkers of tobacco smoke exposure (BOE), especially nicotine, MHBMA, 3-HPMA, S-PMA, 1-OHP and NNAL, when using e-cigarettes and HTPs compared to combustible cigarettes. There was a slight tendency toward a larger reduction in these biomarkers levels with the use of e-cigarettes, although direct comparisons between e-cigarettes and HTPs were lacking. There was also a trend toward positive changes in levels of biomarkers of biological effect (BOBE) with the use of e-cigarettes and HTPs. CONCLUSIONS A comparison of levels of biomarkers of tobacco-related exposure collected in clinical studies revealed that the use of e-cigarettes and HTPs could lead to a significant reduction in exposure to harmful substances compared to combusted cigarettes. In tandem, the health status of e-cigarettes and HTP users, indexed by levels of biomarkers of biological effect showed potential for improvement compared to smoking. However, larger and longer-term population-based studies are needed to further clarify these findings.
Collapse
Key Words
- BAT, British American Tobacco
- BOBE, biomarkers of biological effect
- BOE, biomarkers of tobacco smoke exposure
- Biomarkers of biological effect (BOBE)
- Biomarkers of tobacco smoke exposure (BOE)
- CHTP, Carbon-Heated Tobacco Product
- Clinical study
- E-cigarettes, electronic cigarettes
- EHCSS, Electrically Heated Cigarette Smoking System
- EVPs, electronic vapor products
- Electronic cigarette
- FV, Fontem Ventures
- HC, heated cigarette
- HTPs, heated tobacco products
- Heated tobacco products
- JT, Japan Tobacco
- NOS scale, The Newcastle-Ottawa Scale
- NSPS, nicotine-salt pod system
- NTV, Novel Tobacco vapor products
- PMI, Philip Morris International
- PRISMA, Preferred Reporting Items for Systematic Reviews and Meta-Analyses
- RAI, Reynolds American Inc
- RCT, randomized controlled trial
- RJR, R.J. Reynolds Tobacco Company
- RJRVC, R.J. Reynolds Vapor Company
- RTP, reduced-toxicant-prototype cigarette
- THP, tobacco heating product
- THS, Tobacco Heating System
- UCS, Uncontrolled smoking conditions
- WHO, World Health Organization
- mTHS, Menthol Tobacco Heating System
Collapse
Affiliation(s)
- Yukio Akiyama
- Department of Environmental Management, University of Occupational and Environmental Health, Kitakyushu, Japan
| | | |
Collapse
|
2
|
Haziza C, de La Bourdonnaye G, Donelli A, Skiada D, Poux V, Weitkunat R, Baker G, Picavet P, Lüdicke F. Favorable Changes in Biomarkers of Potential Harm to Reduce the Adverse Health Effects of Smoking in Smokers Switching to the Menthol Tobacco Heating System 2.2 for 3 Months (Part 2). Nicotine Tob Res 2020; 22:549-559. [PMID: 31125079 PMCID: PMC7164580 DOI: 10.1093/ntr/ntz084] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 05/23/2019] [Indexed: 12/17/2022]
Abstract
INTRODUCTION Tobacco Heating System (THS) 2.2, a candidate modified-risk tobacco product, aims at offering an alternative to cigarettes for smokers while substantially reducing the exposure to harmful and potentially harmful constituents found in cigarette smoke. METHODS One hundred and sixty healthy adult US smokers participated in this randomized, three-arm parallel group, controlled clinical study. Subjects were randomized in a 2:1:1 ratio to menthol Tobacco Heating System 2.2 (mTHS), menthol cigarette, or smoking abstinence for 5 days in confinement and 86 subsequent ambulatory days. Endpoints included biomarkers of exposure to harmful and potentially harmful constituents (reported in our co-publication, Part 1) and biomarkers of potential harm (BOPH). RESULTS Compliance (protocol and allocated product exposure) was 51% and 18% in the mTHS and smoking abstinence arms, respectively, on day 90. Nonetheless, favorable changes in BOPHs of lipid metabolism (total cholesterol and high- and low-density cholesterol), endothelial dysfunction (soluble intercellular adhesion molecule-1), oxidative stress (8-epi-prostaglandin F2α), and cardiovascular risk factors (eg, high-sensitivity C-reactive protein) were observed in the mTHS group. Favorable effects in other BOPHs, including ones related to platelet activation (11-dehydrothromboxane B2) and metabolic syndrome (glucose), were more pronounced in normal weight subjects. CONCLUSIONS The results suggest that the reduced exposure demonstrated when switching to mTHS is associated with overall improvements in BOPHs, which are indicative of pathomechanistic pathways underlying the development of smoking-related diseases, with some stronger effects in normal weight subjects. IMPLICATIONS Switching to mTHS was associated with favorable changes for some BOPHs indicative of biological pathway alterations (eg, oxidative stress and endothelial dysfunction). The results suggest that switching to mTHS has the potential to reduce the adverse health effects of smoking and ultimately the risk of smoking-related diseases. Switching to mTHS for 90 days led to reductions in a number of biomarkers of exposure in smokers, relative to those who continued smoking cigarettes, which were close to those observed when stopping smoking (reported in our co-publication, Part 1). Initial findings suggest reduced levels of 8-epi-prostaglandin F2α and intercellular adhesion molecule 1, when switching to mTHS for 90 days. These changes are comparable to what is observed upon smoking cessation. In normal weight subjects, additional favorable changes were seen in 11-dehydrothromboxane B2, fibrinogen, homocysteine, hs-CRP, percentage of predicted forced expiratory volume in 1 second, systolic blood pressure, diastolic blood pressure, glucose, high-density lipoprotein, apolipoprotein A1, and triglycerides. TRIAL REGISTRATION NCT01989156.
Collapse
Affiliation(s)
- Christelle Haziza
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | | | - Andrea Donelli
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Dimitra Skiada
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Valerie Poux
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Rolf Weitkunat
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Gizelle Baker
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Patrick Picavet
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Frank Lüdicke
- PMI Research and Development, Philip Morris Products S.A., Neuchâtel, Switzerland
| |
Collapse
|
3
|
Haziza C, de La Bourdonnaye G, Donelli A, Poux V, Skiada D, Weitkunat R, Baker G, Picavet P, Lüdicke F. Reduction in Exposure to Selected Harmful and Potentially Harmful Constituents Approaching Those Observed Upon Smoking Abstinence in Smokers Switching to the Menthol Tobacco Heating System 2.2 for 3 Months (Part 1). Nicotine Tob Res 2020; 22:539-548. [PMID: 30722062 PMCID: PMC7164581 DOI: 10.1093/ntr/ntz013] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 01/30/2019] [Indexed: 12/11/2022]
Abstract
Introduction The Tobacco Heating System (THS) is a “heat-not-burn” tobacco product designed to generate significantly lower levels of harmful and potentially harmful constituents (HPHCs) and present lower risk of harm than cigarettes. This study assessed the exposure reduction to selected HPHCs in smokers switching to menthol Tobacco Heating System (mTHS) 2.2 compared with smokers continuing smoking menthol cigarettes (mCCs) and smoking abstinence (SA) for 5 days in a confined setting, followed by an 86-day ambulatory period. Methods A total of 160 healthy adult US smokers participated in this randomized, three-arm parallel group, controlled clinical study. Biomarkers of exposure to 16 HPHCs were measured in blood and 24-hour urine. Safety was monitored throughout the study. Information was also gathered on product evaluation, product use, subjective effects, and clinical risk markers (co-publication Part 2). Results Nicotine uptake was comparable in both exposure groups (mTHS:mCC ratio of 96% on day 90). On day 5, biomarker of exposure levels to other HPHCs were reduced by 51%–96% in the mTHS group compared with the mCC group, and these reductions were sustained for most biomarkers of exposure over ambulatory period. After 90 days of use, the level of satisfaction with mTHS and suppression of urge to smoke were comparable to mCC. Conclusion Switching from mCCs to mTHS significantly reduced the exposure to HPHCs to levels approaching those observed in subjects who abstained from smoking for the duration of the study. Implications This study compared the impact of switching to mTHS on biomarkers of exposure, relative to continued smoking or SA. Clinical Significance Trial Registration NCT01989156 (ClinicalTrials.gov).
Collapse
Affiliation(s)
| | | | - Andrea Donelli
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Valerie Poux
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Dimitra Skiada
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Rolf Weitkunat
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Gizelle Baker
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Patrick Picavet
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Frank Lüdicke
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| |
Collapse
|
4
|
Obertova N, Navratil T, Zak I, Zakharov S. Acute exposures to e-cigarettes and heat-not-burn products reported to the Czech Toxicological Information Centre over a 7-year period (2012-2018). Basic Clin Pharmacol Toxicol 2020; 127:39-46. [PMID: 32012431 DOI: 10.1111/bcpt.13393] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 01/13/2020] [Accepted: 01/19/2020] [Indexed: 11/29/2022]
Abstract
E-cigarettes and heat-not-burn cigarettes (HNBC) present new health risks due to their rising popularity, high content of nicotine and serious adverse effects. The objective of the study was to analyse the cases of acute exposure to e-cigarettes, e-liquids and HNBC products containing nicotine that led to toxicological consultations at our poisons control centre during a 7-year period (2012-2018) and identify the categories of special concern that require further investigation and intervention. The demographic, toxicological and clinical data were analysed by descriptive statistics. Poisoning severity score (PSS) was estimated. From 119 229 consultations, 148 cases concerned acute exposure to e-cigarettes. Children and adolescents were exposed in 91 (61%) cases, including exposure of neonates and infants in 54 (36%) cases. The main route of exposure was ingestion in 129 (87%), inhalation in nine (6%), ocular in six (4%) and intravenous administration in three (2%) cases. The source of exposure was the cartridge with e-liquid (107; 72%), refillable tank in 29 (20%) and HNBC refill in nine (6%) cases. The reason for exposure was accidental in 110 (74%), incorrect application of the device in 10 (7%), abuse in six (4%), suicide attempt in six (4%) and other/unknown in 16 (11%) cases. The dose estimation was severe/lethal in 6 (4%), toxic in 53 (36%), low-to-moderate in 35 (24%) and unknown in 54 (36%) cases. Vomiting was observed in 38 (26%) patients; 72% of patients were hospitalised. In symptomatic cases, 41 patient had PSS 1, 12 patients had PSS 2, and one patient had PSS 3. Activated charcoal was applied in 57 (39%) patients, and symptomatic treatment was recommended in 75 (51%) patients. Cases of unintentional exposure of children demonstrate the need for preventive risk reduction measures.
Collapse
Affiliation(s)
- Nikola Obertova
- Toxicological Information Centre, General University Hospital, Prague, Czech Republic.,Department of Occupational Medicine, First Faculty of Medicine, Charles University, Prague, Czech Republic
| | - Tomas Navratil
- Toxicological Information Centre, General University Hospital, Prague, Czech Republic.,Department of Electrochemistry at the Nanoscale, J. Heyrovsky Institute of Physical Chemistry of the Czech Academy of Sciences, Prague, Czech Republic
| | - Ivan Zak
- Toxicological Information Centre, General University Hospital, Prague, Czech Republic.,Department of Occupational Medicine, First Faculty of Medicine, Charles University, Prague, Czech Republic
| | - Sergey Zakharov
- Toxicological Information Centre, General University Hospital, Prague, Czech Republic.,Department of Occupational Medicine, First Faculty of Medicine, Charles University, Prague, Czech Republic
| |
Collapse
|
5
|
Szostak J, Titz B, Schlage WK, Guedj E, Sewer A, Phillips B, Leroy P, Buettner A, Neau L, Trivedi K, Martin F, Ivanov NV, Vanscheeuwijck P, Peitsch MC, Hoeng J. Structural, functional, and molecular impact on the cardiovascular system in ApoE -/- mice exposed to aerosol from candidate modified risk tobacco products, Carbon Heated Tobacco Product 1.2 and Tobacco Heating System 2.2, compared with cigarette smoke. Chem Biol Interact 2020; 315:108887. [PMID: 31705857 DOI: 10.1016/j.cbi.2019.108887] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 10/14/2019] [Accepted: 10/28/2019] [Indexed: 12/26/2022]
Abstract
AIM To investigate the molecular, structural, and functional impact of aerosols from candidate modified risk tobacco products (cMRTP), the Carbon Heated Tobacco Product (CHTP) 1.2 and Tobacco Heating System (THS) 2.2, compared with that of mainstream cigarette smoke (CS) on the cardiovascular system of ApoE-/- mice. METHODS Female ApoE-/- mice were exposed to aerosols from THS 2.2 and CHTP 1.2 or to CS from the 3R4F reference cigarette for up to 6 months at matching nicotine concentrations. A Cessation and a Switching group (3 months exposure to 3R4F CS followed by filtered air or CHTP 1.2 for 3 months) were included. Cardiovascular effects were investigated by echocardiographic, histopathological, immunohistochemical, and transcriptomics analyses. RESULTS Continuous exposure to cMRTP aerosols did not affect atherosclerosis progression, heart function, left ventricular (LV) structure, or the cardiovascular transcriptome. Exposure to 3R4F CS triggered atherosclerosis progression, reduced systolic ejection fraction and fractional shortening, caused heart LV hypertrophy, and initiated significant dysregulation in the transcriptomes of the heart ventricle and thoracic aorta. Importantly, the structural, functional, and molecular changes caused by 3R4F CS were improved in the smoking cessation and switching groups. CONCLUSION Exposure to cMRTP aerosols lacked most of the CS exposure-related functional, structural, and molecular effects. Smoking cessation or switching to CHTP 1.2 aerosol caused similar recovery from the 3R4F CS effects in the ApoE-/- model, with no further acceleration of plaque progression beyond the aging-related rate.
Collapse
Affiliation(s)
- Justyna Szostak
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Bjoern Titz
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Walter K Schlage
- Biology Consultant, Max-Baermann-Str. 21, 51429, Bergisch Gladbach, Germany.
| | - Emmanuel Guedj
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Alain Sewer
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Blaine Phillips
- PMI R&D, Philip Morris International Research Laboratories Pte. Ltd., Science Park II, Singapore.
| | - Patrice Leroy
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | | | - Laurent Neau
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Keyur Trivedi
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Florian Martin
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Nikolai V Ivanov
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Patrick Vanscheeuwijck
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Manuel C Peitsch
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| |
Collapse
|
6
|
Lüdicke F, Picavet P, Baker G, Haziza C, Poux V, Lama N, Weitkunat R. Effects of Switching to the Tobacco Heating System 2.2 Menthol, Smoking Abstinence, or Continued Cigarette Smoking on Biomarkers of Exposure: A Randomized, Controlled, Open-Label, Multicenter Study in Sequential Confinement and Ambulatory Settings (Part 1). Nicotine Tob Res 2019; 20:161-172. [PMID: 28177489 PMCID: PMC5896533 DOI: 10.1093/ntr/ntw287] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Accepted: 10/25/2016] [Indexed: 12/02/2022]
Abstract
Introduction The menthol Tobacco Heating System 2.2 (mTHS) is a newly developed candidate modified-risk tobacco product intended to reduce exposure to the harmful and potentially harmful constituents (HPHCs) of conventional cigarette (CC) smoke. This study examined the impact of switching to mTHS on biomarkers of exposure to HPHCs relative to menthol CCs (mCCs) and smoking abstinence (SA). Methods In this three-arm, parallel-group study, 160 Japanese adult smokers (23–65 years; smoking ≥10 mCCs per day) were randomized to mTHS (n = 78), mCC (n = 42), or SA (n = 40) for 5 days in confinement and 85 days in ambulatory settings. Endpoints included biomarkers of exposure to HPHCs, human puffing topography, safety, and subjective effects of smoking measures. Results After 5 days of product use, the concentrations of carboxyhemoglobin, 3-hydroxypropylmercapturic acid, monohydroxybutenyl mercapturic acid, and S-phenylmercapturic acid were 55%, 49%, 87%, and 89% lower (p < .001), respectively, in the mTHS group than in the mCC group. Other biomarkers of exposure (measured as secondary endpoints) were 50%–94% lower in the mTHS group than in the mCC group on day 5. These reductions in the mTHS group were maintained at day 90, similar to the SA group. Switching to mTHS was associated with changes in human puffing topography (shorter puff intervals and more frequent puffs). The urge-to-smoke and smoking satisfaction levels on day 90 were similar in the mTHS and the mCC groups. Conclusion Switching from mCCs to mTHS significantly reduced exposure to HPHCs relative to continuing smoking mCCs with concentrations similar to those observed following SA in Japanese adult smokers. Implications This randomized study compared the impact of switching to a modified-risk tobacco product candidate mTHS on biomarkers of exposure to HPHCs of cigarette smoke relative to continuing smoking cigarettes or abstaining from smoking in sequential confinement and ambulatory settings. The study showed that switching to mTHS was associated with significant biomarker reductions within 5 days in confinement, these reductions being maintained throughout the ambulatory setting up to day 90. The results provide evidence that switching to mTHS reduces real-life exposure to HPHCs in adult smokers.
Collapse
Affiliation(s)
- Frank Lüdicke
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Patrick Picavet
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Gizelle Baker
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Christelle Haziza
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Valerie Poux
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Nicola Lama
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| | - Rolf Weitkunat
- Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland
| |
Collapse
|
7
|
Nabavizadeh P, Liu J, Havel CM, Ibrahim S, Derakhshandeh R, Jacob Iii P, Springer ML. Vascular endothelial function is impaired by aerosol from a single IQOS HeatStick to the same extent as by cigarette smoke. Tob Control 2018; 27:s13-s19. [PMID: 30206183 PMCID: PMC6202192 DOI: 10.1136/tobaccocontrol-2018-054325] [Citation(s) in RCA: 94] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 05/10/2018] [Accepted: 05/11/2018] [Indexed: 12/22/2022]
Abstract
BACKGROUND Heated tobacco products (also called 'heat-not-burn' products) heat tobacco at temperatures below that of combustion, causing nicotine and other compounds to aerosolise. One such product, IQOS from Philip Morris International, is being marketed internationally with claims of harm reduction. We sought to determine whether exposure to IQOS aerosol impairs arterial flow-mediated dilation (FMD), a measure of vascular endothelial function that is impaired by tobacco smoke. METHODS We exposed anaesthetised rats (n=8/group) via nose cone to IQOS aerosol from single HeatSticks, mainstream smoke from single Marlboro Red cigarettes or clean air for a series of consecutive 30 s cycles over 1.5-5 min. Each cycle consisted of 15 or 5 s of exposure followed by removal from the nose cone. We measured pre-exposure and postexposure FMD, and postexposure serum nicotine and cotinine. RESULTS FMD was impaired comparably by ten 15 s exposures and ten 5 s exposures to IQOS aerosol and to cigarette smoke, but not by clean air. Serum nicotine levels were similar to plasma levels after humans have smoked one cigarette, confirming that exposure conditions had real-world relevance. Postexposure nicotine levels were ~4.5-fold higher in rats exposed to IQOS than to cigarettes, despite nicotine being measured in the IQOS aerosol at ~63% the amount measured in smoke. When IQOS exposure was briefer, leading to comparable serum nicotine levels to the cigarette group, FMD was still comparably impaired. CONCLUSIONS Acute exposures to IQOS aerosol impairs FMD in rats. IQOS use does not necessarily avoid the adverse cardiovascular effects of smoking cigarettes.
Collapse
Affiliation(s)
- Pooneh Nabavizadeh
- Cardiovascular Research Institute, University of California, San Francisco, San Francisco, California, USA
| | - Jiangtao Liu
- Cardiovascular Research Institute, University of California, San Francisco, San Francisco, California, USA
| | - Christopher M Havel
- Division of Clinical Pharmacology and Experimental Therapeutics, University of California, San Francisco, San Francisco, California, USA
| | - Sharina Ibrahim
- Division of Cardiology, University of California, San Francisco, San Francisco, California, USA
| | - Ronak Derakhshandeh
- Cardiovascular Research Institute, University of California, San Francisco, San Francisco, California, USA
| | - Peyton Jacob Iii
- Division of Clinical Pharmacology and Experimental Therapeutics, University of California, San Francisco, San Francisco, California, USA
- Center for Tobacco Control Research and Education, University of California, San Francisco, San Francisco, California, USA
| | - Matthew L Springer
- Cardiovascular Research Institute, University of California, San Francisco, San Francisco, California, USA
- Division of Cardiology, University of California, San Francisco, San Francisco, California, USA
- Center for Tobacco Control Research and Education, University of California, San Francisco, San Francisco, California, USA
| |
Collapse
|
8
|
Suitability of biomarkers of biological effects (BOBEs) for assessing the likelihood of reducing the tobacco related disease risk by new and innovative tobacco products: A literature review. Regul Toxicol Pharmacol 2018; 94:203-233. [DOI: 10.1016/j.yrtph.2018.02.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Revised: 02/04/2018] [Accepted: 02/05/2018] [Indexed: 02/07/2023]
|
9
|
Martin F, Vuillaume G, Baker G, Sponsiello-Wang Z, Ricci PF, Lüdicke F, Weitkunat R. Quantifying the risk-reduction potential of new Modified Risk Tobacco Products. Regul Toxicol Pharmacol 2018; 92:358-369. [PMID: 29258927 DOI: 10.1016/j.yrtph.2017.12.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 12/04/2017] [Accepted: 12/15/2017] [Indexed: 12/31/2022]
Abstract
Quantitative risk assessment of novel Modified Risk Tobacco Products (MRTP) must rest on indirect measurements that are indicative of disease development prior to epidemiological data becoming available. For this purpose, a Population Health Impact Model (PHIM) has been developed to estimate the reduction in the number of deaths from smoking-related diseases following the introduction of an MRTP. One key parameter of the model, the F-factor, describes the effective dose upon switching from cigarette smoking to using an MRTP. Biomarker data, collected in clinical studies, can be analyzed to estimate the effects of switching to an MRTP as compared to quitting smoking. Based on transparent assumptions, a link function is formulated that translates these effects into the F-factor. The concepts of 'lack of sufficiency' and 'necessity' are introduced, allowing for a parametrization of a family of link functions. These can be uniformly sampled, thus providing different 'scenarios' on how biomarker-based evidence can be translated into the F-factor to inform the PHIM.
Collapse
Affiliation(s)
- Florian Martin
- Philip Morris International Research & Development, Neuchâtel, Switzerland
| | - Gregory Vuillaume
- Philip Morris International Research & Development, Neuchâtel, Switzerland
| | - Gizelle Baker
- Philip Morris International Research & Development, Neuchâtel, Switzerland
| | | | | | - Frank Lüdicke
- Philip Morris International Research & Development, Neuchâtel, Switzerland
| | - Rolf Weitkunat
- Philip Morris International Research & Development, Neuchâtel, Switzerland.
| |
Collapse
|
10
|
Lüdicke F, Baker G, Magnette J, Picavet P, Weitkunat R. Reduced Exposure to Harmful and Potentially Harmful Smoke Constituents With the Tobacco Heating System 2.1. Nicotine Tob Res 2017; 19:168-175. [PMID: 27613951 PMCID: PMC5234364 DOI: 10.1093/ntr/ntw164] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Accepted: 06/27/2016] [Indexed: 11/23/2022]
Abstract
INTRODUCTION Heating rather than burning tobacco reduces levels of harmful and potentially harmful constituents, and consumer products using this approach aim to reduce exposure to tobacco toxicants. The Tobacco Heating System (THS) version 2.1 has been enhanced from earlier prototypes with an improved heat control and sensorial experience and thereby user acceptance. Exposure measurements are required to determine whether it may be possible to reduce the individual health risk compared to smoking combustible cigarettes (CCs). METHODS This controlled clinical study randomly assigned 40 smokers to either a group continuing to use of their own CC brand (n = 20) or a group switching to THS 2.1 (n = 20) for 5 days. Biomarkers of exposure were measured at baseline and on day 1 through day 5. Product consumption, Human Puffing Topography, the occurrence of adverse events, and an assessment of subjective effects, such as smoking satisfaction and enjoyment of respiratory tract sensations, were also determined. RESULTS The group of smokers who switched to THS 2.1 adapted their puffing behavior initially through longer puff duration and more puffs. During the duration of the study, total puff volume returned to baseline levels and the mean daily product consumption increased but with similar nicotine exposure compared to baseline CC use. Biomarkers of exposure to tobacco smoke toxicants which inform product risk assessment were significantly reduced with THS use compared to the CC group. THS 2.1 users experienced less reinforcing effects with THS 2.1 than with their own cigarette brand. CONCLUSIONS THS 2.1 is a promising alternative to smoking CCs. Notwithstanding possible use adaption through consumption or puffing behavior, the exposure to harmful smoke constituents was markedly reduced with the new heated tobacco platform. IMPLICATIONS Exposure markers to harmful and potentially harmful smoke constituents were lowered with the THS 2.1. Heating tobacco instead of burning can offer a potentially lower risk of delivering nicotine compared to CCs.
Collapse
Affiliation(s)
- Frank Lüdicke
- Philip Morris Products S.A., Research & Development, Neuchâtel, Switzerland
| | - Gizelle Baker
- Philip Morris Products S.A., Research & Development, Neuchâtel, Switzerland
| | - John Magnette
- Philip Morris Products S.A., Research & Development, Neuchâtel, Switzerland
| | - Patrick Picavet
- Philip Morris Products S.A., Research & Development, Neuchâtel, Switzerland
| | - Rolf Weitkunat
- Philip Morris Products S.A., Research & Development, Neuchâtel, Switzerland
| |
Collapse
|
11
|
Evaluation of the Tobacco Heating System 2.2. Part 1: Description of the system and the scientific assessment program. Regul Toxicol Pharmacol 2016; 81 Suppl 2:S17-S26. [DOI: 10.1016/j.yrtph.2016.07.006] [Citation(s) in RCA: 169] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Accepted: 07/08/2016] [Indexed: 11/19/2022]
|
12
|
Pisinger C, Døssing M. A systematic review of health effects of electronic cigarettes. Prev Med 2014; 69:248-60. [PMID: 25456810 DOI: 10.1016/j.ypmed.2014.10.009] [Citation(s) in RCA: 322] [Impact Index Per Article: 29.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2014] [Revised: 09/19/2014] [Accepted: 10/09/2014] [Indexed: 11/18/2022]
Abstract
OBJECTIVE To provide a systematic review of the existing literature on health consequences of vaporing of electronic cigarettes (ECs). METHODS Search in: PubMed, EMBASE and CINAHL. INCLUSION CRITERIA Original publications describing a health-related topic, published before 14 August 2014. PRISMA recommendations were followed. We identified 1101 studies; 271 relevant after screening; 94 eligible. RESULTS We included 76 studies investigating content of fluid/vapor of ECs, reports on adverse events and human and animal experimental studies. Serious methodological problems were identified. In 34% of the articles the authors had a conflict of interest. Studies found fine/ultrafine particles, harmful metals, carcinogenic tobacco-specific nitrosamines, volatile organic compounds, carcinogenic carbonyls (some in high but most in low/trace concentrations), cytotoxicity and changed gene expression. Of special concern are compounds not found in conventional cigarettes, e.g. propylene glycol. Experimental studies found increased airway resistance after short-term exposure. Reports on short-term adverse events were often flawed by selection bias. CONCLUSIONS Due to many methodological problems, severe conflicts of interest, the relatively few and often small studies, the inconsistencies and contradictions in results, and the lack of long-term follow-up no firm conclusions can be drawn on the safety of ECs. However, they can hardly be considered harmless.
Collapse
Affiliation(s)
- Charlotta Pisinger
- Research Centre for Prevention and Health, Glostrup Hospital, DK-2600 Glostrup, Denmark.
| | - Martin Døssing
- Medicinsk Afdeling, Frederikssund Hospital, DK-3600 Frederikssund, Denmark
| |
Collapse
|
13
|
Tricker AR, Jang IJ, Martin Leroy C, Lindner D, Dempsey R. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 4: Eight-day randomized clinical trial in Korea. Regul Toxicol Pharmacol 2012; 64:S45-53. [PMID: 22951346 DOI: 10.1016/j.yrtph.2012.08.013] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 11/25/2022]
Abstract
A randomized, controlled, open-label parallel-group, single-center study to determine biomarkers of exposure to 12 selected harmful and potentially harmful constituents (HPHC) in cigarette smoke and urinary excretion of mutagenic material in 72 male and female Korean subjects smoking Lark One cigarettes (1.0mg tar, 0.1mg nicotine, and 1.5mg CO) at baseline. Subjects were randomized to continue smoking Lark One cigarettes, or switch to an Electrically Heated Cigarette Smoking System (EHCSS) and EHCSS-K3 cigarette (3mg tar, 0.2mg nicotine, and 0.6 mg CO), or to no-smoking. The mean decreases from baseline to Day 8 were statistically significant (all p<0.05) for 10 of 12 HPHC in mainstream cigarette smoke including CO (the primary objective) in the EHCSS-K3 group (range: -1.5% to -74.2%). Exposure to the other determined HPHC was not significantly different. In the Lark One group, the mean exposure to 6 of 12 HPHC in cigarette smoke was significantly (all p<0.05) decreased; however, exposure to CO was significantly increased. The largest mean reductions in biomarkers of exposure to HPHC occurred in smokers who switched to no-smoking (-3.4% to -98.9%). The mean excretion of mutagenic material was significantly decreased (p<0.05) in the EHCSS-K3 and no-smoking groups (-31.8% and -45.3%, respectively), and increased in the Lark One group (+31.5%).
Collapse
Affiliation(s)
- Anthony R Tricker
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland.
| | | | | | | | | |
Collapse
|
14
|
Martin Leroy C, Jarus-Dziedzic K, Ancerewicz J, Lindner D, Kulesza A, Magnette J. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 7: A one-month, randomized, ambulatory, controlled clinical study in Poland. Regul Toxicol Pharmacol 2012; 64:S74-84. [PMID: 22951349 DOI: 10.1016/j.yrtph.2012.08.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 01/01/2023]
Abstract
This randomized, open-label, ambulatory, controlled clinical study investigated biomarkers associated with cardiovascular risk and biomarkers of exposure to 10 selected harmful and potentially harmful constituents (HPHC) in cigarette smoke in 316 male and female Polish smokers. Subjects were randomized to continue smoking conventional cigarettes (CC; N=79) or switch to smoking the Electrically Heated Cigarette Smoking System series-K cigarette (EHCSS-K6; N=237). Biomarker assessments were performed at several time points during the study at baseline and during the 1-month investigational period. The primary biomarkers were high-sensitivity C-reactive protein and white blood cell counts. No statistically significant differences in the two primary biomarkers were found between the study groups at the end of the study. End-of-study comparisons of secondary biomarkers between study groups indicated an increase in high-density lipoprotein cholesterol, and reductions in red blood cell count, hemoglobin, and hematocrit levels in the EHCSS-K6 group. All biomarkers of exposure to cigarette smoke HPHC were decreased in the EHCSS-K6 group, despite an increase in cigarette consumption, compared to the CC group. There were no apparent differences in any of the safety assessment parameters between the groups, and the overall incidence of study-related adverse events was low.
Collapse
Affiliation(s)
- Claire Martin Leroy
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland
| | | | | | | | | | | |
Collapse
|
15
|
Tricker AR, Stewart AJ, Leroy CM, Lindner D, Schorp MK, Dempsey R. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 3: Eight-day randomized clinical trial in the UK. Regul Toxicol Pharmacol 2012; 64:S35-44. [PMID: 22940436 DOI: 10.1016/j.yrtph.2012.08.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 01/26/2023]
Abstract
A randomized, controlled, open-label, parallel-group, single-center study to determine biomarkers of exposure to nine selected harmful and potentially harmful constituents (HPHC) in cigarette smoke and urinary excretion of mutagenic material in 160 male and female subjects smoking Marlboro cigarettes (6 mg tar, 0.5mg nicotine, and 7.0mg CO) at baseline. Subjects were randomized to continue smoking Marlboro cigarettes, or switch to using an Electrically Heated Cigarette Smoking System (EHCSS) smoking one of two EHCSS series-K cigarettes, the EHCSS-K6 cigarette (5mg tar, 0.3mg nicotine, and 0.6 mg CO) or the EHCSS-K3 cigarette (3mg tar, 0.2mg nicotine, and 0.6 mg CO), or switch to smoking Philip Morris One cigarettes (1mg tar, 0.1mg nicotine, and 2.0mg CO), or to no-smoking. The mean decreases from baseline to Day 8 were statistically significant (p ≤ 0.05) for all determined HPHC including benzene and CO (the primary objectives), and urinary excretion of mutagenic material in the EHCSS-K6 (range -35.5 ± 29.2% to -79.4 ± 14.6% [mean ± standard deviation]), EHCSS-K3 (range -41.2 ± 26.6% to -83.1 ± 9.2%), and PM1 (range -14.6 ± 24.1% to -39.4 ± 17.5%) groups. The largest reductions in exposure occurred in the no-smoking group (range -55.4 ± 45.0% to -100.0 ± 0.0%).
Collapse
Affiliation(s)
- Anthony R Tricker
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland.
| | | | | | | | | | | |
Collapse
|
16
|
Zenzen V, Diekmann J, Gerstenberg B, Weber S, Wittke S, Schorp MK. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 2: Smoke chemistry and in vitro toxicological evaluation using smoking regimens reflecting human puffing behavior. Regul Toxicol Pharmacol 2012; 64:S11-34. [PMID: 22922180 DOI: 10.1016/j.yrtph.2012.08.004] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 11/28/2022]
Abstract
Chemical analysis of up to 49 harmful and potentially harmful constituents (HPHC) in mainstream smoke, in vitro cytotoxicity of the particulate and gas/vapor phase of mainstream smoke determined in the Neutral Red Uptake assay, and in vitro bacterial mutagenicity of the particulate phase determined in the Salmonella typhimurium Reverse Mutation (Ames) assay are reported for three Electrically Heated Cigarette Smoking System (EHCSS) series-K cigarettes, the University of Kentucky Reference Cigarette 2R4F, and a number of comparator commercial conventional lit-end cigarettes (CC) under ISO machine-smoking conditions and a total of 25 additional smoking regimens reflecting 'human puffing behavior' (HPB). The smoking machines were set to deliver nicotine yields for the EHCSS and comparator CC derived from the 10th percentile to the 90th percentile of nicotine uptake distributions in smokers determined in two clinical studies. Duplication of the smoking intensity 'per cigarette' on a smoking machine may provide an insight into product performance that is directly relevant to obtaining scientific evidence for reduced exposure substantiation based on mainstream cigarette smoke HPHC-to-nicotine regressions. The reported data support an overall evaluation of reduced exposure to HPHC and biological activity.
Collapse
Affiliation(s)
- Volker Zenzen
- Philip Morris International R&D, Philip Morris Research Laboratories GmbH, Fuggerstrasse 3, 51149 Cologne, Germany
| | | | | | | | | | | |
Collapse
|
17
|
Schorp MK, Tricker AR, Dempsey R. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 1: Non-clinical and clinical insights. Regul Toxicol Pharmacol 2012; 64:S1-10. [PMID: 22940435 DOI: 10.1016/j.yrtph.2012.08.008] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 01/16/2023]
Abstract
The following series of papers presents an extensive assessment of the Electrically Heated Cigarette Smoking System EHCSS series-K cigarette vs. conventional lit-end cigarettes (CC) as an example for an extended testing strategy for evaluation of reduced exposure. The EHCSS produces smoke through electrical heating of tobacco. The EHCSS series-K heater was designed for exclusive use with EHCSS cigarettes, and cannot be used to smoke (CC). Compared to the University of Kentucky Reference Research cigarette 2R4F and a series of commercial CC, mainstream cigarette smoke of both the non-menthol and menthol-flavored EHCSS cigarettes showed a reduced delivery of a series of selected harmful and potentially harmful constituents (HPHC), mutagenic activity determined using the Salmonella typhimurium Reverse Mutation (Ames) assay, and cytotoxicity in the Neutral Red Uptake Assay. Clinical evaluations confirmed reduced exposure to HPHC and excretion of mutagenic material under controlled clinical conditions. Reductions in HPHC exposure were confirmed in a real-world ambulatory clinical study. Potential biomarkers of cardiovascular risk were also reduced under real-world ambulatory conditions. A modeling approach, 'nicotine bridging', was developed based on the determination of nicotine exposure in clinical evaluations which indicated that exposure to HPHC for which biomarkers of exposure do not exist would also be reduced.
Collapse
Affiliation(s)
- Matthias K Schorp
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland.
| | | | | |
Collapse
|
18
|
Tricker AR, Kanada S, Takada K, Leroy CM, Lindner D, Schorp MK, Dempsey R. Reduced exposure evaluation of an Electrically Heated Cigarette Smoking System. Part 5: 8-Day randomized clinical trial in Japan. Regul Toxicol Pharmacol 2012; 64:S54-63. [PMID: 22940437 DOI: 10.1016/j.yrtph.2012.08.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 01/09/2023]
Abstract
A randomized, controlled, open-label, parallel-group, single-center study to determine biomarkers of exposure to twelve selected harmful and potentially harmful constituents (HPHCs) in cigarette smoke and urinary excretion of mutagenic material in 128 male and female Japanese subjects smoking Marlboro cigarettes (6 mg tar, 0.5mg nicotine, and 7.0mg CO) at baseline. Subjects were randomized to continue smoking Marlboro cigarettes, or switch to the Electrically Heated Cigarette Smoking System (EHCSS) and smoke either the EHCSS-K6 (5mg tar, 0.3mg nicotine, and 0.6 mg CO) or the EHCSS-K3 (3mg tar, 0.2mg nicotine, and 0.6 mg CO) cigarette, or switch to smoking Lark One cigarettes (1mg tar, 0.1mg nicotine, and 2.0mg CO), or to no-smoking. The mean decreases from baseline to Day 8 were statistically significant (p ≤ 0.05) for all cigarette smoke HPHC including CO (the primary objective) and excretion of mutagenic material in the EHCSS-K6 (range: -14.6% to -75.6%) and EHCSS-K3 (range: -9.8% to -73.0%) groups. Statistically significant reductions (all p ≤ 0.05) in exposure to ten cigarette smoke HPHC (range: -5.9% to -34.6%), but not urinary mutagenicity, were observed in the Lark One group. The largest mean reductions in exposure to HPHC (all p ≤ 0.01 level) occurred in the no-smoking group (range: -13.7% to -97.6%).
Collapse
Affiliation(s)
- Anthony R Tricker
- Philip Morris International R&D, Philip Morris Products SA, Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland.
| | | | | | | | | | | | | |
Collapse
|