1
|
Petzold LM, Busse M, Mohr H, Pellegata NS, Pfeiffer F, Herzen J. Development of a H&E multi-agent-staining method for laboratory-microCT applied to endocrine glands of MENX rats. DEVELOPMENTS IN X-RAY TOMOGRAPHY XV 2024:3. [DOI: 10.1117/12.3029584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
2
|
Zandarco S, Günther B, Riedel M, Breitenhuber G, Kirst M, Achterhold K, Pfeiffer F, Herzen J. Speckle tracking phase-contrast computed tomography at an inverse Compton X-ray source. OPTICS EXPRESS 2024; 32:28472-28488. [PMID: 39538663 DOI: 10.1364/oe.528701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Accepted: 06/10/2024] [Indexed: 11/16/2024]
Abstract
Speckle-based X-ray imaging (SBI) is a phase-contrast method developed at and for highly coherent X-ray sources, such as synchrotrons, to increase the contrast of weakly absorbing objects. Consequently, it complements the conventional attenuation-based X-ray imaging. Meanwhile, attempts to establish SBI at less coherent laboratory sources have been performed, ranging from liquid metal-jet X-ray sources to microfocus X-ray tubes. However, their lack of coherence results in interference fringes not being resolved. Therefore, algorithms were developed which neglect the interference effects. Here, we demonstrate phase-contrast computed tomography employing SBI in a laboratory-setting with an inverse Compton X-ray source. In this context, we investigate and compare also the performance of the at synchrotron conventionally used phase-retrieval algorithms for SBI, unified modulated pattern analysis (UMPA) with a phase-retrieval method developed for low coherence systems (LCS). We successfully retrieve a full computed tomography in a phantom as well as in biological specimens, such as larvae of the greater wax moth (Galleria mellonella), a model system for studies of pathogens and infections. In this context, we additionally demonstrate quantitative phase-contrast computed tomography using SBI at a low coherent set-up.
Collapse
|
3
|
Tao S, Tian Z, Bai L, Xu Y, Kuang C, Liu X. Phase retrieval for X-ray differential phase contrast radiography with knowledge transfer learning from virtual differential absorption model. Comput Biol Med 2024; 168:107711. [PMID: 37995534 DOI: 10.1016/j.compbiomed.2023.107711] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 10/31/2023] [Accepted: 11/15/2023] [Indexed: 11/25/2023]
Abstract
Grating-based X-ray phase contrast radiography and computed tomography (CT) are promising modalities for future medical applications. However, the ill-posed phase retrieval problem in X-ray phase contrast imaging has hindered its use for quantitative analysis in biomedical imaging. Deep learning has been proved as an effective tool for image retrieval. However, in practical grating-based X-ray phase contrast imaging system, acquiring the ground truth of phase to form image pairs is challenging, which poses a great obstacle for using deep leaning methods. Transfer learning is widely used to address the problem with knowledge inheritance from similar tasks. In the present research, we propose a virtual differential absorption model and generate a training dataset with differential absorption images and absorption images. The knowledge learned from the training is transferred to phase retrieval with transfer learning techniques. Numerical simulations and experiments both demonstrate its feasibility. Image quality of retrieved phase radiograph and phase CT slices is improved when compared with representative phase retrieval methods. We conclude that this method is helpful in both X-ray 2D and 3D imaging and may find its applications in X-ray phase contrast radiography and X-ray phase CT.
Collapse
Affiliation(s)
- Siwei Tao
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Zonghan Tian
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Ling Bai
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yueshu Xu
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310027, China; State Key Laboratory of Extreme Photonics and Instrumentation, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 315100, China
| | - Cuifang Kuang
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310027, China; State Key Laboratory of Extreme Photonics and Instrumentation, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 315100, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, 030006, China.
| | - Xu Liu
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, 310027, China; State Key Laboratory of Extreme Photonics and Instrumentation, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 315100, China; Ningbo Research Institute, Zhejiang University, Ningbo, 315100, China.
| |
Collapse
|
4
|
Omori NE, Bobitan AD, Vamvakeros A, Beale AM, Jacques SDM. Recent developments in X-ray diffraction/scattering computed tomography for materials science. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2023; 381:20220350. [PMID: 37691470 PMCID: PMC10493554 DOI: 10.1098/rsta.2022.0350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Accepted: 07/17/2023] [Indexed: 09/12/2023]
Abstract
X-ray diffraction/scattering computed tomography (XDS-CT) methods are a non-destructive class of chemical imaging techniques that have the capacity to provide reconstructions of sample cross-sections with spatially resolved chemical information. While X-ray diffraction CT (XRD-CT) is the most well-established method, recent advances in instrumentation and data reconstruction have seen greater use of related techniques like small angle X-ray scattering CT and pair distribution function CT. Additionally, the adoption of machine learning techniques for tomographic reconstruction and data analysis are fundamentally disrupting how XDS-CT data is processed. The following narrative review highlights recent developments and applications of XDS-CT with a focus on studies in the last five years. This article is part of the theme issue 'Exploring the length scales, timescales and chemistry of challenging materials (Part 2)'.
Collapse
Affiliation(s)
- Naomi E. Omori
- Finden Limited, Merchant House, 5 East St Helens Street,Abingdon OX14 5EG, UK
| | - Antonia D. Bobitan
- Finden Limited, Merchant House, 5 East St Helens Street,Abingdon OX14 5EG, UK
- Department of Chemistry, University College London, 20 Gordon Street, London WC1H 0AJ, UK
- Research Complex at Harwell, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, Oxon OX11 0FA, UK
| | - Antonis Vamvakeros
- Finden Limited, Merchant House, 5 East St Helens Street,Abingdon OX14 5EG, UK
- Dyson School of Design Engineering, Imperial College London, London SW7 2DB, UK
| | - Andrew M. Beale
- Finden Limited, Merchant House, 5 East St Helens Street,Abingdon OX14 5EG, UK
- Department of Chemistry, University College London, 20 Gordon Street, London WC1H 0AJ, UK
- Research Complex at Harwell, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, Oxon OX11 0FA, UK
| | - Simon D. M. Jacques
- Finden Limited, Merchant House, 5 East St Helens Street,Abingdon OX14 5EG, UK
| |
Collapse
|
5
|
Tao S, Tian Z, Bai L, Wang W, Xu Y, Kuang C, Liu X. Tri-directional x-ray phase contrast multimodal imaging using one hexagonal mesh modulator. Phys Med Biol 2023; 68:195017. [PMID: 37652041 DOI: 10.1088/1361-6560/acf5c3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 08/31/2023] [Indexed: 09/02/2023]
Abstract
Objective. X-ray phase contrast imaging is a promising technique for future clinical diagnostic as it can provide enhanced contrast in soft tissues compared to traditional x-ray attenuation-contrast imaging. However, the strict requirements on the x-ray coherence and the precise alignment of optical elements limit its applications towards clinical use. To solve this problem, mesh-based x-ray phase contrast imaging method with one hexagonal mesh is proposed for easy alignment and better image visualization.Approach. The mesh produces structured illuminations and the detector captures its distortions to reconstruct the absorption, differential phase contrast (DPC) and dark-field (DF) images of the sample. In this work, we fabricated a hexagonal mesh to simultaneously retrieve DPC and DF signals in three different directions with single shot. A phase retrieval algorithm to obtain artifacts-free phase from DPC images with three different directions is put forward and false color dark-field image is also reconstructed with tri-directional images. Mesh-shifting method based on this hexagonal mesh modulator is also proposed to reconstruct images with better image quality at the expense of increased dose.Main results. In numerical simulations, the proposed hexagonal mesh outperforms the traditional square mesh in image evaluation metrics performance and false color visualization with the same radiation dose. The experimental results demonstrate its feasiblity in real imaging systems and its advantages in quantitive imaging and better visualization. The proposed hexagonal mesh is easy to fabricate and can be successfully applied to x-ray source with it spot size up to 300μm.Significance. This work opens new possibilities for quantitative x-ray non-destructive imaging and may also be instructive for research fields such as x-ray structured illumination microscopy (SIM), x-ray spectral imaging and x-ray phase contrast and dark-field computed tomography (CT).
Collapse
Affiliation(s)
- Siwei Tao
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Zonghan Tian
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Ling Bai
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Wei Wang
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Yueshu Xu
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
- State Key Laboratory of Extreme Photonics and Instrumentation, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou 315100, People's Republic of China
| | - Cuifang Kuang
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
- State Key Laboratory of Extreme Photonics and Instrumentation, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou 315100, People's Republic of China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, People's Republic of China
| | - Xu Liu
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
- State Key Laboratory of Extreme Photonics and Instrumentation, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou 315100, People's Republic of China
- Ningbo Research Institute, Zhejiang University, Ningbo 315100, People's Republic of China
| |
Collapse
|
6
|
Pfeiffer F, Willer K, Viermetz M, Pfeiffer D. [Dark-field imaging and computed tomography : Novel X-ray-based contrast imaging modality with great promise for pulmonary imaging]. RADIOLOGIE (HEIDELBERG, GERMANY) 2023:10.1007/s00117-023-01161-4. [PMID: 37341743 DOI: 10.1007/s00117-023-01161-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Accepted: 05/03/2023] [Indexed: 06/22/2023]
Abstract
INTRODUCTION The spatial and contrast resolution of conventional planar or computed tomographic X‑ray techniques is not sufficient to investigate microstructures of tissues. Dark-field imaging with X‑rays is an emerging technology that recently provided the first clinical results and makes diagnostic use of interactions of the beams with tissue due to their wave character. APPLICATION Dark-field imaging can provide information about the microscopic structure or porosity of the tissue under investigation that is otherwise inaccessible. This makes it a valuable complement to conventional X‑ray imaging, which can only account for attenuation. Our results demonstrate that X‑ray dark-field imaging provides pictorial information about the underlying microstructure of the lung in humans. Given the close relationship between alveolar structure and the functional state of the lung, this is of great importance for diagnosis and therapy monitoring and may contribute to a better understanding of lung diseases in the future. In the early detection of chronic obstructive pulmonary disease, which is usually associated with structural impairment of the lung, this novel technique could help to facilitate its diagnosis. PERSPECTIVE The application of dark-field imaging to computed tomography is still under development because it is technically difficult. Meanwhile, a prototype for experimental application has been developed and is currently being tested on a variety of materials. Use in humans is conceivable especially for tissues whose microstructure favors characteristic interactions due to the wave nature of the X‑rays.
Collapse
Affiliation(s)
- Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748, Garching, Deutschland.
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Deutschland.
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, 81675, München, Deutschland.
| | - Konstantin Willer
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748, Garching, Deutschland
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Deutschland
| | - Manuel Viermetz
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748, Garching, Deutschland
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Deutschland
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, 81675, München, Deutschland
- Institute for Advanced Study, Technical University of Munich, 85748, Garching, Deutschland
| |
Collapse
|
7
|
Vijayakumar J, Goudarzi NM, Eeckhaut G, Schrijnemakers K, Cnudde V, Boone MN. Characterization of Pharmaceutical Tablets by X-ray Tomography. Pharmaceuticals (Basel) 2023; 16:ph16050733. [PMID: 37242516 DOI: 10.3390/ph16050733] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 05/07/2023] [Accepted: 05/08/2023] [Indexed: 05/28/2023] Open
Abstract
Solid dosage forms such as tablets are extensively used in drug administration for their simplicity and large-scale manufacturing capabilities. High-resolution X-ray tomography is one of the most valuable non-destructive techniques to investigate the internal structure of the tablets for drug product development as well as for a cost effective production process. In this work, we review the recent developments in high-resolution X-ray microtomography and its application towards different tablet characterizations. The increased availability of powerful laboratory instrumentation, as well as the advent of high brilliance and coherent 3rd generation synchrotron light sources, combined with advanced data processing techniques, are driving the application of X-ray microtomography forward as an indispensable tool in the pharmaceutical industry.
Collapse
Affiliation(s)
- Jaianth Vijayakumar
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| | - Niloofar Moazami Goudarzi
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| | - Guy Eeckhaut
- Janssen Pharmaceutica, Turnhoutseweg 30, 2340 Beerse, Belgium
| | | | - Veerle Cnudde
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Pore-Scale Processes in Geomaterials Research (PProGRess), Department of Geology, Ghent University, Krijgslaan 281/S8, 9000 Gent, Belgium
- Environmental Hydrogeology, Department of Earth Sciences, Faculty of Geosciences, Utrecht University, Princetonlaan 8A, 3584 CD Utrecht, The Netherlands
| | - Matthieu N Boone
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| |
Collapse
|
8
|
Zhai R, Fang B, Lai Y, Peng B, Bai H, Liu X, Li L, Huang W. Small-molecule fluorogenic probes for mitochondrial nanoscale imaging. Chem Soc Rev 2023; 52:942-972. [PMID: 36514947 DOI: 10.1039/d2cs00562j] [Citation(s) in RCA: 40] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Mitochondria are inextricably linked to the development of diseases and cell metabolism disorders. Super-resolution imaging (SRI) is crucial in enhancing our understanding of mitochondrial ultrafine structures and functions. In addition to high-precision instruments, super-resolution microscopy relies heavily on fluorescent materials with unique photophysical properties. Small-molecule fluorogenic probes (SMFPs) have excellent properties that make them ideal for mitochondrial SRI. This paper summarizes recent advances in the field of SMFPs, with a focus on the chemical and spectroscopic properties required for mitochondrial SRI. Finally, we discuss future challenges in this field, including the design principles of SMFPs and nanoscopic techniques.
Collapse
Affiliation(s)
- Rongxiu Zhai
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering (IBME), Northwestern Polytechnical University, Xi'an 710072, China.
| | - Bin Fang
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering (IBME), Northwestern Polytechnical University, Xi'an 710072, China. .,School of Materials Science and Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China
| | - Yaqi Lai
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering (IBME), Northwestern Polytechnical University, Xi'an 710072, China.
| | - Bo Peng
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering (IBME), Northwestern Polytechnical University, Xi'an 710072, China.
| | - Hua Bai
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering (IBME), Northwestern Polytechnical University, Xi'an 710072, China.
| | - Xiaowang Liu
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering (IBME), Northwestern Polytechnical University, Xi'an 710072, China.
| | - Lin Li
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering (IBME), Northwestern Polytechnical University, Xi'an 710072, China. .,The Institute of Flexible Electronics (IFE, Future Technologies), Xiamen University, Xiamen 361005, Fujian, China
| | - Wei Huang
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering (IBME), Northwestern Polytechnical University, Xi'an 710072, China. .,The Institute of Flexible Electronics (IFE, Future Technologies), Xiamen University, Xiamen 361005, Fujian, China
| |
Collapse
|
9
|
Dierks H, Stjärneblad P, Wallentin J. A versatile laboratory setup for high resolution X-ray phase contrast tomography and scintillator characterization. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2023; 31:1-12. [PMID: 36404526 PMCID: PMC9912733 DOI: 10.3233/xst-221294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/11/2022] [Accepted: 10/30/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND X-ray micro-tomography (μCT) is a powerful non-destructive 3D imaging method applied in many scientific fields. In combination with propagation-based phase-contrast, the method is suitable for samples with low absorption contrast. Phase contrast tomography has become available in the lab with the ongoing development of micro-focused tube sources, but it requires sensitive and high-resolution X-ray detectors. The development of novel scintillation detectors, particularly for microscopy, requires more flexibility than available in commercial tomography systems. OBJECTIVE We aim to develop a compact, flexible, and versatile μCT laboratory setup that combines absorption and phase contrast imaging as well as the option to use it for scintillator characterization. Here, we present details on the design and implementation of the setup. METHODS We used the setup for μCT in absorption and propagation-based phase-contrast mode, as well as to study a perovskite scintillator. RESULTS We show the 2D and 3D performance in absorption and phase contrast mode, as well as how the setup can be used for testing new scintillator materials in a realistic imaging environment. A spatial resolution of around 1.3μm is measured in 2D and 3D. CONCLUSIONS The setup meets the needs for common absorption μCT applications and offers increased contrast in phase contrast mode. The availability of a versatile laboratory μCT setup allows not only for easy access to tomographic measurements, but also enables a prompt monitoring and feedback beneficial for advances in scintillator fabrication.
Collapse
Affiliation(s)
- Hanna Dierks
- Lund University, Synchrotron Radiation Research and NanoLund, Lund, Sweden
| | - Philip Stjärneblad
- Lund University, Synchrotron Radiation Research and NanoLund, Lund, Sweden
| | - Jesper Wallentin
- Lund University, Synchrotron Radiation Research and NanoLund, Lund, Sweden
| |
Collapse
|
10
|
Yang JS, Jeon SY, Choi JH. Acquisition of a single grid-based phase-contrast X-ray image using instantaneous frequency and noise filtering. Biomed Eng Online 2022; 21:92. [PMID: 36575491 PMCID: PMC9793636 DOI: 10.1186/s12938-022-01061-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 12/20/2022] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND To obtain phase-contrast X-ray images, single-grid imaging systems are effective, but Moire artifacts remain a significant issue. The solution for removing Moire artifacts from an image is grid rotation, which can distinguish between these artifacts and sample information within the Fourier space. However, the mechanical movement of grid rotation is slower than the real-time change in Moire artifacts. Thus, Moire artifacts generated during real-time imaging cannot be removed using grid rotation. To overcome this problem, we propose an effective method to obtain phase-contrast X-ray images using instantaneous frequency and noise filtering. RESULT The proposed phase-contrast X-ray image using instantaneous frequency and noise filtering effectively suppressed noise with Moire patterns. The proposed method also preserved the clear edge of the inner and outer boundaries and internal anatomical information from the biological sample, outperforming conventional Fourier analysis-based methods, including absorption, scattering, and phase-contrast X-ray images. In particular, when comparing the phase information for the proposed method with the x-axis gradient image from the absorption image, the proposed method correctly distinguished two different types of soft tissue and the detailed information, while the latter method did not. CONCLUSION This study successfully achieved a significant improvement in image quality for phase-contrast X-ray images using instantaneous frequency and noise filtering. This study can provide a foundation for real-time bio-imaging research using three-dimensional computed tomography.
Collapse
Affiliation(s)
- Jae-Suk Yang
- grid.255649.90000 0001 2171 7754Division of Mechanical and Biomedical Engineering, Graduate Program in System Health Science and Engineering, Ewha Womans University, Seoul, 03760 Republic of Korea
| | - Sun-Young Jeon
- grid.255649.90000 0001 2171 7754Division of Mechanical and Biomedical Engineering, Graduate Program in System Health Science and Engineering, Ewha Womans University, Seoul, 03760 Republic of Korea
| | - Jang-Hwan Choi
- grid.255649.90000 0001 2171 7754Division of Mechanical and Biomedical Engineering, Graduate Program in System Health Science and Engineering, Ewha Womans University, Seoul, 03760 Republic of Korea
| |
Collapse
|
11
|
Lioliou G, Roche i Morgó O, Marathe S, Wanelik K, Cipiccia S, Olivo A, Hagen CK. Cycloidal-spiral sampling for three-modal x-ray CT flyscans with two-dimensional phase sensitivity. Sci Rep 2022; 12:21336. [PMID: 36494470 PMCID: PMC9734192 DOI: 10.1038/s41598-022-25999-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 12/07/2022] [Indexed: 12/13/2022] Open
Abstract
We present a flyscan compatible acquisition scheme for three-modal X-Ray Computed Tomography (CT) with two-dimensional phase sensitivity. Our approach is demonstrated using a "beam tracking" setup, through which a sample's attenuation, phase (refraction) and scattering properties can be measured from a single frame, providing three complementary contrast channels. Up to now, such setups required the sample to be stepped at each rotation angle to sample signals at an adequate rate, to prevent resolution losses, anisotropic resolution, and under-sampling artefacts. However, the need for stepping necessitated a step-and-shoot implementation, which is affected by motors' overheads and increases the total scan time. By contrast, our proposed scheme, by which continuous horizontal and vertical translations of the sample are integrated with its rotation (leading to a "cycloidal-spiral" trajectory), is fully compatible with continuous scanning (flyscans). This leads to greatly reduced scan times while largely preserving image quality and isotropic resolution.
Collapse
Affiliation(s)
- G. Lioliou
- grid.83440.3b0000000121901201Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT UK
| | - O. Roche i Morgó
- grid.83440.3b0000000121901201Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT UK
| | - S. Marathe
- grid.18785.330000 0004 1764 0696Diamond Light Source, Harwell Science and Innovation Campus, Fermi Avenue, Didcot, OX11 0DE UK
| | - K. Wanelik
- grid.18785.330000 0004 1764 0696Diamond Light Source, Harwell Science and Innovation Campus, Fermi Avenue, Didcot, OX11 0DE UK
| | - S. Cipiccia
- grid.83440.3b0000000121901201Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT UK
| | - A. Olivo
- grid.83440.3b0000000121901201Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT UK
| | - C. K. Hagen
- grid.83440.3b0000000121901201Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT UK
| |
Collapse
|
12
|
Sanctorum J, Sijbers J, De Beenhouwer J. Virtual grating approach for Monte Carlo simulations of edge illumination-based x-ray phase contrast imaging. OPTICS EXPRESS 2022; 30:38695-38708. [PMID: 36258428 DOI: 10.1364/oe.472145] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 09/05/2022] [Indexed: 06/16/2023]
Abstract
The design of new x-ray phase contrast imaging setups often relies on Monte Carlo simulations for prospective parameter studies. Monte Carlo simulations are known to be accurate but time consuming, leading to long simulation times, especially when many parameter variations are required. This is certainly the case for imaging methods relying on absorbing masks or gratings, with various tunable properties, such as pitch, aperture size, and thickness. In this work, we present the virtual grating approach to overcome this limitation. By replacing the gratings in the simulation with virtual gratings, the parameters of the gratings can be changed after the simulation, thereby significantly reducing the overall simulation time. The method is validated by comparison to explicit grating simulations, followed by representative demonstration cases.
Collapse
|
13
|
Zhang G, Li J, Deng K, Yue S, Xie W. Reweighted L1-norm regularized phase retrieval for x-ray differential phase contrast radiograph. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:043706. [PMID: 35489897 DOI: 10.1063/5.0081145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 03/10/2022] [Indexed: 06/14/2023]
Abstract
Talbot-Lau x-ray grating interferometry greatly decreases the requirements on x-ray sources to realize differential phase contrast imaging and has found many applications in industrial and medical imaging. Phase retrieval from the noisy differential signal is crucial for quantitative analysis, comparison, and fusion with other imaging modalities. In this paper, we introduce a reweighted L1-norm based nonlinear regularization method for the phase retrieval problem. Both simulation and experimental results demonstrated that, comparing with the widely used L1-norm based regularization method and Wiener filter method, the proposed method is more effective both in eliminating the strip noises and in preserving the image detail.
Collapse
Affiliation(s)
- Guangya Zhang
- Chinese Academy of Engineering Physics, Institute Fluid Physics, Mianyang 621999, China
| | - Jing Li
- Chinese Academy of Engineering Physics, Institute Fluid Physics, Mianyang 621999, China
| | - Kai Deng
- Chinese Academy of Engineering Physics, Institute Fluid Physics, Mianyang 621999, China
| | - Songjie Yue
- Chinese Academy of Engineering Physics, Institute Fluid Physics, Mianyang 621999, China
| | - Weiping Xie
- Chinese Academy of Engineering Physics, Institute Fluid Physics, Mianyang 621999, China
| |
Collapse
|
14
|
Fabrication of X-ray absorption gratings by centrifugal deposition of bimodal tungsten particles in high aspect ratio silicon templates. Sci Rep 2022; 12:5405. [PMID: 35354819 PMCID: PMC8968707 DOI: 10.1038/s41598-022-08222-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 03/03/2022] [Indexed: 11/08/2022] Open
Abstract
Grating-based X-ray imaging employs high aspect ratio absorption gratings to generate contrast induced by attenuating, phase-shifting, and small-angle scattering properties of the imaged object. The fabrication of the absorption gratings remains a crucial challenge of the method on its pathway to clinical applications. We explore a simple and fast centrifugal tungsten particle deposition process into silicon-etched grating templates, which has decisive advantages over conventional methods. For that, we use a bimodal tungsten particle suspension which is introduced into a custom designed grating holder and centrifuged at over 1000×g. Gratings with 45 µm period, 450 µm depth, and 170 mm × 38 mm active area are successfully processed reaching a homogeneous absorber filling. The effective absorbing tungsten thickness in the trenches is 207 µm resulting in a filling ratio of 46.6% compared to a voidless filling. The grating was tested in a Talbot–Lau interferometer designed for clinical X-ray dark-field computed tomography, where visibilities up to 33.6% at 60 kV were achieved.
Collapse
|
15
|
Semi-classical Monte Carlo algorithm for the simulation of X-ray grating interferometry. Sci Rep 2022; 12:2485. [PMID: 35169138 PMCID: PMC8847374 DOI: 10.1038/s41598-022-05965-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Accepted: 01/12/2022] [Indexed: 11/08/2022] Open
Abstract
Traditional simulation techniques such as wave optics methods and Monte Carlo (MC) particle transport cannot model both interference and inelastic scattering phenomena within one framework. Based on the rules of quantum mechanics to calculate probabilities, we propose a new semi-classical MC algorithm for efficient and simultaneous modeling of scattering and interference processes. The similarities to MC particle transport allow the implementation as a flexible c++ object oriented extension of EGSnrc-a well-established MC toolkit. In addition to previously proposed Huygens principle based transport through optics components, new variance reduction techniques for the transport through gratings are presented as transport options to achieve the required improvement in speed and memory costs necessary for an efficient exploration (system design-dose estimations) of the medical implementation of X-ray grating interferometry (GI), an emerging imaging technique currently subject of tremendous efforts towards clinical translation. The feasibility of simulation of interference effects is confirmed in four academic cases and an experimental table-top GI setup. Comparison with conventional MC transport show that deposited energy features of EGSnrc are conserved.
Collapse
|
16
|
Yin M, Yuan M, Deng K, Li J, Zhang G, Zhu J, Xie W, Wu J. Subcutaneous Low-Density Foreign Bodies Detection via Grating-Based Multimodal X-ray Imaging. J Digit Imaging 2022; 35:365-373. [PMID: 35064371 PMCID: PMC8921381 DOI: 10.1007/s10278-021-00569-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 11/10/2021] [Accepted: 12/08/2021] [Indexed: 11/28/2022] Open
Abstract
Detecting low-density foreign bodies within soft tissues still stands for a serious challenge. Grating-based multimodal X-ray imaging typically has low hardware requirements while simultaneously providing three kinds of imaging information, i.e., absorption, phase-contrast, and dark-field. We aimed to explore the capacity of grating-based multimodal X-ray imaging technology for detecting common foreign bodies within subcutaneous tissues, and to assess the advantages as well as disadvantages of the three kinds of images obtained via grating-based X-ray multimodal technology in relation to diverse kinds of foreign bodies within different tissues. In this study, metal, glass, wood, plastic, graphite, and ceramic foreign bodies were injected into chunks of the pig adipose tissue and chicken thigh muscles. Next, a grating-based multimodal X-ray imaging device developed in our laboratory was used to detect the above foreign bodies within the adipose and muscle tissues. Our results show that grating-based multimodal X-ray imaging clearly revealed the subcutaneous foreign bodies within the adipose and muscle tissues by acquiring complementary absorption, phase-contrast, and dark-field imaging data in a single shot. Grating-based multimodal X-ray imaging has an exciting potential to detect foreign bodies underneath the epidermis.
Collapse
Affiliation(s)
- Meifang Yin
- Department of Burn and Plastic Surgery, Department of Wound Repair, Shenzhen Institute of Translational Medicine, The First Affiliated Hospital of Shenzhen University, Second People's Hospital, ShenzhenShenzhen, 518035, China
| | - Mingzhou Yuan
- Department of Burn Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China
| | - Kai Deng
- Institute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, 621999, China
| | - Jing Li
- Institute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, 621999, China
| | - Guangya Zhang
- Institute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, 621999, China
| | - Jiayuan Zhu
- Department of Burn Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China
| | - Weiping Xie
- Institute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, 621999, China.
| | - Jun Wu
- Department of Burn and Plastic Surgery, Department of Wound Repair, Shenzhen Institute of Translational Medicine, The First Affiliated Hospital of Shenzhen University, Second People's Hospital, ShenzhenShenzhen, 518035, China.
| |
Collapse
|
17
|
Birnbacher L, Braig EM, Pfeiffer D, Pfeiffer F, Herzen J. Quantitative X-ray phase contrast computed tomography with grating interferometry : Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography. Eur J Nucl Med Mol Imaging 2021; 48:4171-4188. [PMID: 33846846 PMCID: PMC8566444 DOI: 10.1007/s00259-021-05259-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 02/11/2021] [Indexed: 11/25/2022]
Abstract
The ability of biomedical imaging data to be of quantitative nature is getting increasingly important with the ongoing developments in data science. In contrast to conventional attenuation-based X-ray imaging, grating-based phase contrast computed tomography (GBPC-CT) is a phase contrast micro-CT imaging technique that can provide high soft tissue contrast at high spatial resolution. While there is a variety of different phase contrast imaging techniques, GBPC-CT can be applied with laboratory X-ray sources and enables quantitative determination of electron density and effective atomic number. In this review article, we present quantitative GBPC-CT with the focus on biomedical applications.
Collapse
Affiliation(s)
- Lorenz Birnbacher
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Eva-Maria Braig
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Franz Pfeiffer
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Julia Herzen
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany.
| |
Collapse
|
18
|
Ram S, Han MK. X-ray dark field imaging: a tool for early diagnosis of emphysema in chronic obstructive pulmonary disease? LANCET DIGITAL HEALTH 2021; 3:e691-e692. [PMID: 34711374 DOI: 10.1016/s2589-7500(21)00230-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Accepted: 09/09/2021] [Indexed: 11/25/2022]
Affiliation(s)
- Sundaresh Ram
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - MeiLan K Han
- Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, MI 48109, USA.
| |
Collapse
|
19
|
Pyakurel U, Sun W, Cheung P, D'Moore D, Zhang X, MacDonald CA, Petruccelli JC. Phase and dark-field imaging with mesh-based structured illumination and polycapillary optics. Med Phys 2021; 48:6642-6657. [PMID: 34554583 DOI: 10.1002/mp.15247] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 08/23/2021] [Accepted: 09/07/2021] [Indexed: 12/30/2022] Open
Abstract
PURPOSE X-ray phase and dark-field (DF) imaging have been shown to improve the diagnostic capabilities of X-ray systems. However, these methods have found limited clinical use due to the need for multiple precision gratings with limited field of view or requirements on X-ray coherence that may not be easily translated to clinical practice. This work aims to develop a practicable X-ray phase and DF imaging system that could be translated and practiced in the clinic. METHODS This work employs a conventional source to create structured illumination with a simple wire mesh. A mesh-shifting algorithm is used to allow wider Fourier windowing to enhance resolution. Deconvolution of the source spot width and camera resolution improves accuracy. Polycapillary optics are employed to enhance coherence. The effects of incorporating optics with two different focal lengths are compared. Information apparent in enhanced absorption images, phase images, and DF images of fat embedded phantoms were compared and subjected to a limited receiver operator characteristic (ROC) study. The DF images of the moist and dry porous object (sponges) were compared. RESULTS The mesh-based phase and DF imaging system constructs images with three different information types: scatter-free absorption images, differential phase images, and scatter magnitude/DF images, simultaneously from the same original image. The polycapillary optic enhances the coherence of the beam. The deblurring technique corrects the phase signal error due to geometrical blur and the limitation of the camera modulation transfer function (MTF) and removes image artifacts to improve the resolution in a single shot. The mesh-shifting method allows the use of a wider Fourier processing window, which gives even higher resolution, at the expense of an increased dose. The limited ROC study confirms the efficacy of the system over the conventional system. DF images of moist and dry porous object show the significance of the system in the imaging of lung infections. CONCLUSION The mesh-based X-ray phase and DF imaging system is an inexpensive and easy setup in terms of alignment and data acquisition and can produce phase and DF images in a single shot with wide field of view. The system shows significant potential for use in diagnostic imaging in a clinical setting.
Collapse
Affiliation(s)
- Uttam Pyakurel
- Department of Physics, University at Albany, Albany, New York, USA
| | - Weiyuan Sun
- Department of Physics, University at Albany, Albany, New York, USA
| | - Pikting Cheung
- Department of Physics, University at Albany, Albany, New York, USA
| | - Desirée D'Moore
- Department of Physics, University at Albany, Albany, New York, USA
| | - Xiaoyun Zhang
- Department of Physics, University at Albany, Albany, New York, USA.,Nuclear Science and Technology, Beijing Normal University, Beijing, China
| | | | | |
Collapse
|
20
|
Olivo A. Edge-illumination x-ray phase-contrast imaging. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2021; 33:363002. [PMID: 34167096 PMCID: PMC8276004 DOI: 10.1088/1361-648x/ac0e6e] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 06/07/2021] [Accepted: 06/24/2021] [Indexed: 05/08/2023]
Abstract
Although early demonstration dates back to the mid-sixties, x-ray phase-contrast imaging (XPCI) became hugely popular in the mid-90s, thanks to the advent of 3rd generation synchrotron facilities. Its ability to reveal object features that had so far been considered invisible to x-rays immediately suggested great potential for applications across the life and the physical sciences, and an increasing number of groups worldwide started experimenting with it. At that time, it looked like a synchrotron facility was strictly necessary to perform XPCI with some degree of efficiency-the only alternative being micro-focal sources, the limited flux of which imposed excessively long exposure times. However, new approaches emerged in the mid-00s that overcame this limitation, and allowed XPCI implementations with conventional, non-micro-focal x-ray sources. One of these approaches showing particular promise for 'real-world' applications is edge-illumination XPCI: this article describes the key steps in its evolution in the context of contemporary developments in XPCI research, and presents its current state-of-the-art, especially in terms of transition towards practical applications.
Collapse
Affiliation(s)
- Alessandro Olivo
- Department of Medical Physics and Biomedical Engineering, UCL, London, United Kingdom
| |
Collapse
|
21
|
Calcified cartilage revealed in whole joint by X-ray phase contrast imaging. OSTEOARTHRITIS AND CARTILAGE OPEN 2021; 3:100168. [DOI: 10.1016/j.ocarto.2021.100168] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 04/09/2021] [Indexed: 11/19/2022] Open
|
22
|
Zheng M, Zhao Y, Han S, Ji D, Li Y, Lv W, Xin X, Zhao X, Hu C. Iterative reconstruction algorithm based on discriminant adaptive-weighted TV regularization for fibrous biological tissues using in-line X-ray phase-contrast imaging. BIOMEDICAL OPTICS EXPRESS 2021; 12:2460-2483. [PMID: 33996241 PMCID: PMC8086461 DOI: 10.1364/boe.418898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Revised: 03/10/2021] [Accepted: 03/16/2021] [Indexed: 05/07/2023]
Abstract
In-line X-ray phase-contrast computed tomography (IL-PCCT) can produce high-contrast and high-resolution images of biological samples, and it has a great advantage with regard to imaging the microstructures and morphologies of fibrous biological tissues (FBTs). Filtered back projection (FBP) is widely used in ILPCCT. However, it requires long scanning times and high radiation doses to produce high-quality CT images, and this restricts its applicability in biomedical and preclinical studies on FBTs. To solve this problem, a novel IL-PCCT reconstruction algorithm is proposed to decrease the radiation dose by reducing the number of projections and reconstruct high-quality CT images of FBTs. The proposed algorithm incorporates the FBP method into the iterative reconstruction framework. Considering the area types and anisotropic edge properties of FBTs, a discriminant adaptive-weighted total variation model is introduced to optimize the intermediate reconstructed images. A fibrous phantom simulation and real experiment were performed to assess the performance of the proposed algorithm. Simulation and experimental results demonstrated that the proposed algorithm is an effective IL-PCCT reconstruction method for FBTs with incomplete projection data, and it has a great ability to suppress artifacts and preserve the edges of fibrous structures.
Collapse
Affiliation(s)
- Mengting Zheng
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin 300070, China
- These authors contributed equally to this work
| | - Yuqing Zhao
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin 300070, China
- These authors contributed equally to this work
| | - Shuo Han
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin 300070, China
| | - Dongjiang Ji
- The School of Science, Tianjin University of Technology and Education, Tianjin 300222, China
| | - Yimin Li
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin 300070, China
| | - Wenjuan Lv
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin 300070, China
| | - Xiaohong Xin
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin 300070, China
| | - Xinyan Zhao
- Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing100050, China
| | - Chunhong Hu
- School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin 300070, China
| |
Collapse
|
23
|
Abstract
Numerous advances have been made in X-ray technology in recent years. X-ray imaging plays an important role in the nondestructive exploration of the internal structures of objects. However, the contrast of X-ray absorption images remains low, especially for materials with low atomic numbers, such as biological samples. X-ray phase-contrast images have an intrinsically higher contrast than absorption images. In this review, the principles, milestones, and recent progress of X-ray phase-contrast imaging methods are demonstrated. In addition, prospective applications are presented.
Collapse
|
24
|
Emons J, Fasching PA, Wunderle M, Heindl F, Rieger J, Horn F, Pelzer G, Ritter A, Weber T, Radicke M, Polifka I, Wachter DL, Wenkel E, Michel T, Uder M, Hartmann A, Anton G, Beckmann MW, Schulz-Wendtland R, Jud SM. Assessment of the additional clinical potential of X-ray dark-field imaging for breast cancer in a preclinical setup. Ther Adv Med Oncol 2020; 12:1758835920957932. [PMID: 32994806 PMCID: PMC7502853 DOI: 10.1177/1758835920957932] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 08/20/2020] [Indexed: 12/01/2022] Open
Abstract
Background: Mammography can identify calcifications up to 50–100 μm in size as a surrogate parameter for breast cancer or ductal carcinoma in situ (DCIS). Microcalcifications measuring <50 µm are also associated with breast cancer or DCIS and are frequently not detected on mammography, although they can be detected with dark-field imaging. This study examined whether additional breast examination using X-ray dark-field imaging can increase the detection rate of calcifications. Advances in knowledge: (1) evaluation of additional modality of breast imaging; (2) specific evaluation of breast calcifications. Implications for patient care: the addition of X-ray dark-field imaging to conventional mammography could detect additional calcifications. Methods: Talbot–Lau X-ray phase–contrast imaging and X-ray dark-field imaging were used to acquire images of breast specimens. The radiation dosage with the technique is comparable with conventional mammography. Three X-ray gratings with periods of 5–10 µm between the X-ray tube and the flat-panel detector provide three different images in a single sequence: the conventional attenuation image, differential phase image, and dark-field image. The images were read by radiologists. Radiological findings were marked and examined pathologically. The results were described in a descriptive manner. Results: A total of 81 breast specimens were investigated with the two methods; 199 significant structures were processed pathologically, consisting of 123 benign and 76 malignant lesions (DCIS or invasive breast cancer). X-ray dark-field imaging identified 15 additional histologically confirmed carcinoma lesions that were visible but not declared suspicious on digital mammography alone. Another four malignant lesions that were not visible on mammography were exclusively detected with X-ray dark-field imaging. Conclusions: Adding X-ray dark-field imaging to digital mammography increases the detection rate for breast cancer and DCIS associated lesions with micrometer-sized calcifications. The use of X-ray dark-field imaging may be able to provide more accurate and detailed radiological classification of suspicious breast lesions. Adding X-ray dark-field imaging to mammography may be able to increase the detection rate and improve preoperative planning in deciding between mastectomy or breast-conserving therapy, particularly in patients with invasive lobular breast cancer.
Collapse
Affiliation(s)
- Julius Emons
- Department of Gynecology and Obstetrics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Bayern, Germany
| | - Peter A Fasching
- Department of Gynecology and Obstetrics, Erlangen University Hospital, Comprehensive Cancer Center Erlangen-EMN, Universitätsstrasse 21-23, Erlangen 91054, Germany
| | - Marius Wunderle
- Department of Gynecology and Obstetrics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Bayern, Germany
| | - Felix Heindl
- Department of Gynecology and Obstetrics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Bayern, Germany
| | - Jens Rieger
- Erlangen Center for Astroparticle Physics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Germany
| | - Florian Horn
- Erlangen Center for Astroparticle Physics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Germany
| | - Georg Pelzer
- Erlangen Center for Astroparticle Physics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Germany
| | - Andre Ritter
- Erlangen Center for Astroparticle Physics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Germany
| | - Thomas Weber
- Erlangen Center for Astroparticle Physics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Germany
| | | | - Iris Polifka
- Institute of Pathology, Erlangen University Hospital, Erlangen, Germany
| | - David L Wachter
- Institute of Pathology, Erlangen University Hospital, Erlangen, Germany
| | - Evelyn Wenkel
- Institute of Diagnostic Radiology, Erlangen University Hospital, Erlangen, Bayern, Germany
| | - Thilo Michel
- Erlangen Center for Astroparticle Physics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Germany
| | - Michael Uder
- Institute of Diagnostic Radiology, Erlangen University Hospital, Erlangen, Bayern, Germany
| | - Arndt Hartmann
- Institute of Pathology, Erlangen University Hospital, Erlangen, Germany
| | - Gisela Anton
- Erlangen Center for Astroparticle Physics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Germany
| | - Matthias W Beckmann
- Department of Gynecology and Obstetrics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Bayern, Germany
| | | | - Sebastian M Jud
- Department of Gynecology and Obstetrics, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen, Bayern, Germany
| |
Collapse
|
25
|
Kim Y, Kim D, Lee S, Kim J, Hussey DS, Lee SW. Neutron grating interferometer with an analyzer grating based on a light blocker. OPTICS EXPRESS 2020; 28:23284-23293. [PMID: 32752327 DOI: 10.1364/oe.391678] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 06/26/2020] [Indexed: 06/11/2023]
Abstract
We study an analyzer grating based on a scintillation light blocker for a Talbot-Lau grating interferometer. This is an alternative way to analyze the Talbot self-image without the need for an often difficult to fabricate absorption grating for the incident radiation. The feasibility of this approach using a neutron beam has been evaluated and experiments have been conducted at the cold neutron imaging facility of the NIST center for Neutron Research. The neutron grating interferometer with the proposed analyzer grating successfully produced attenuation, differential phase, and dark-field contrast images. In addition, numerical simulations were performed to simulate the Talbot pattern and visibility using scintillation screens of different thicknesses and there is good agreement with the experimental measurements. The results show potential for reducing the difficulty of fabricating analyzer grating, and a possibility for the so-called shadow effect to be eliminated and large-area gratings to be produced, especially when applied to X-rays. We report the performance of the analyzer grating based on a light blocker and evaluate its feasibility for the grating interferometer.
Collapse
|
26
|
Imaging features in post-mortem x-ray dark-field chest radiographs and correlation with conventional x-ray and CT. Eur Radiol Exp 2019; 3:25. [PMID: 31292790 PMCID: PMC6620231 DOI: 10.1186/s41747-019-0104-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Accepted: 05/29/2019] [Indexed: 02/01/2023] Open
Abstract
Background Although x-ray dark-field imaging has been intensively investigated for lung imaging in different animal models, there is very limited data about imaging features in the human lungs. Therefore, in this work, a reader study on nine post-mortem human chest x-ray dark-field radiographs was performed to evaluate dark-field signal strength in the lungs, intraobserver and interobserver agreement, and image quality and to correlate with findings of conventional x-ray and CT. Methods In this prospective work, chest x-ray dark-field radiography with a tube voltage of 70 kVp was performed post-mortem on nine humans (3 females, 6 males, age range 52–88 years). Visual quantification of dark-field and transmission signals in the lungs was performed by three radiologists. Results were compared to findings on conventional x-rays and 256-slice computed tomography. Image quality was evaluated. For ordinal data, median, range, and dot plots with medians and 95% confidence intervals are presented; intraobserver and interobserver agreement were determined using weighted Cohen κ. Results Dark-field signal grading showed significant differences between upper and middle (p = 0.004–0.016, readers 1–3) as well as upper and lower zones (p = 0.004–0.016, readers 1–2). Median transmission grading was indifferent between all lung regions. Intraobserver and interobserver agreements were substantial to almost perfect for grading of both dark-field (κ = 0.793–0.971 and κ = 0.828–0.893) and transmission images (κ = 0.790–0.918 and κ = 0.700–0.772). Pulmonary infiltrates correlated with areas of reduced dark-field signal. Image quality was rated good for dark-field images. Conclusions Chest x-ray dark-field images provide information of the lungs complementary to conventional x-ray and allow reliable visual quantification of dark-field signal strength. Electronic supplementary material The online version of this article (10.1186/s41747-019-0104-7) contains supplementary material, which is available to authorized users.
Collapse
|
27
|
Duan J, Hu C, Qiu Q, Zhang J, Meng H, Wang K, Dong H, Wei H, Yin Y. Characterization of microvessels and parenchyma in in-line phase contrast imaging CT: healthy liver, cirrhosis and hepatocellular carcinoma. Quant Imaging Med Surg 2019; 9:1037-1046. [PMID: 31367557 DOI: 10.21037/qims.2019.06.12] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Background Hepatocellular carcinoma (HCC) is a cancer with a poor prognosis, and approximately 80% of HCC cases develop from cirrhosis. Imaging techniques in the clinic seem to be insufficient for revealing the microstructures of liver disease. In recent years, phase contrast imaging CT (PCI-CT) has opened new avenues for biomedical applications owing to its unprecedented spatial and contrast resolution. The aim of this study was to present three-dimensional (3D) visualization of human healthy liver, cirrhosis and HCC using a PCI-CT technique called in-line phase contrast imaging CT (ILPCI-CT) and to quantitatively evaluate the variations of these tissues, focusing on the liver parenchyma and microvasculature. Methods Tissue samples from 9 surgical specimens of normal liver (n=3), cirrhotic liver (n=2), and HCC (n=4) were imaged using ILPCI-CT at the Shanghai Synchrotron Radiation Facility (SSRF) without contrast agents. 3D visualization of all ex vivo liver samples are presented. To quantitatively evaluate the vessel features, the vessel branch angles of each sample were clearly depicted. Additionally, radiomic features of the liver parenchyma extracted from the 3D images were measured. To evaluate the stability of the features, the percent coefficient of variation (%COV) was calculated for each radiomic feature. A %COV <30 was considered to be low variation. Finally, one-way ANOVA, followed by Tukey's test, was used to determine significant changes among the different liver specimens. Results ILPCI-CT allows for a clearer view of the architecture of the vessels and reveals more structural details than does conventional radiography. Combined with the 3D visualization technique, ILPCI-CT enables the acquisition of an accurate description of the 3D vessel morphology in liver samples. Qualitative descriptions and quantitative assessment of microvessels demonstrated clear differences among human healthy liver, cirrhotic liver and HCC. In total, 38 (approximately 51%) radiomic features had low variation, including 11 first-order features, 16 GLCM features, 6 GLRLM features and 5 GLSZM features. The differences in the mean vessel branch angles and 3 radiomic features (first-order entropy, GLCM-inverse variance and GLCM-sum entropy) were statistically significant among the three groups of samples. Conclusions ILPCI-CT may allow for morphologic descriptions and quantitative evaluation of vessel microstructures and parenchyma in human healthy liver, cirrhotic liver and HCC. Vessel branch angles and radiomic features extracted from liver parenchyma images can be used to distinguish the three kinds of liver tissues.
Collapse
Affiliation(s)
- Jinghao Duan
- School of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China.,Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan 250117, China
| | - Chunhong Hu
- College of Biomedical Engineering, Tianjin Medical University, Tianjin 300070, China
| | - Qingtao Qiu
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan 250117, China
| | - Jing Zhang
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan 250117, China
| | - Huipeng Meng
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Keqiang Wang
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Huajiang Dong
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Hong Wei
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan 250117, China
| | - Yong Yin
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Ji'nan 250117, China
| |
Collapse
|
28
|
Gustschin N, Gustschin A, Meyer P, Viermetz M, Riederer P, Herzen J, Mohr J, Pfeiffer F. Quality and parameter control of X-ray absorption gratings by angular X-ray transmission. OPTICS EXPRESS 2019; 27:15943-15955. [PMID: 31163783 DOI: 10.1364/oe.27.015943] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Accepted: 02/17/2019] [Indexed: 06/09/2023]
Abstract
Here we report on a non-destructive, spatially resolving and easy to implement quality and parameter control method for high aspect ratio X-ray absorption gratings. Based on angular X-ray transmission measurements, our proposed technique allows to determine the duty cycle, the transmittance, the height, as well as the local inclination of the absorbing grating structures. A key advantage of the presented method is a fast and extensive grating quality evaluation without the need of implementing an entire grating interferometer. In addition to the local and surface-based analysis using a scanning electron microscope, our non-destructive method provides global averaged macroscopic and spatially resolved grating structure information without the requirement of resolving individual grating lines.
Collapse
|
29
|
3D grating-based X-ray phase-contrast computed tomography for high-resolution quantitative assessment of cartilage: An experimental feasibility study with 3T MRI, 7T MRI and biomechanical correlation. PLoS One 2019; 14:e0212106. [PMID: 30763375 PMCID: PMC6375589 DOI: 10.1371/journal.pone.0212106] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Accepted: 01/28/2019] [Indexed: 01/21/2023] Open
Abstract
Objective Aim of this study was, to demonstrate the feasibility of high-resolution grating-based X-ray phase-contrast computed tomography (PCCT) for quantitative assessment of cartilage. Materials and methods In an experimental setup, 12 osteochondral samples were harvested from n = 6 bovine knees (n = 2 each). From each knee, one cartilage sample was degraded using 2.5% Trypsin. In addition to PCCT and biomechanical cartilage stiffness measurements, 3T and 7T MRI was performed including MSME SE T2 and ME GE T2* mapping sequences for relaxationtime measurements. Paired t-tests and receiver operating characteristics (ROC) curves were used for statistical analyses. Results PCCT provided high-resolution images for improved morphological cartilage evaluation as compared to 3T and 7T MRI. Quantitative analyses revealed significant differences between the superficial and the deep cartilage layer for T2 mapping as well as for PCCT (P<0.05). No significant difference was detected for PCCT between healthy and degraded samples (P>0.05). MRI and stiffness measurements showed significant differences between healthy and degraded osteochondral samples. Accuracy in the prediction of cartilage degradation was excellent for MRI and biomechanical analyses. Conclusion In conclusion, high-resolution grating-based X-ray PCCT cartilage imaging is feasible. In addition to MRI and biomechanical analyses it provides complementary, water content independent, information for improved morphological and quantitative characterization of articular cartilage ultrastructure.
Collapse
|
30
|
Baran P, Mayo S, McCormack M, Pacile S, Tromba G, Dullin C, Zanconati F, Arfelli F, Dreossi D, Fox J, Prodanovic Z, Cholewa M, Quiney H, Dimmock M, Nesterets Y, Thompson D, Brennan P, Gureyev T. High-Resolution X-Ray Phase-Contrast 3-D Imaging of Breast Tissue Specimens as a Possible Adjunct to Histopathology. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:2642-2650. [PMID: 29994112 DOI: 10.1109/tmi.2018.2845905] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Histopathological analysis is the current gold standard in breast cancer diagnosis and management, however, as imaging technology improves, the amount of potential diagnostic information that may be demonstrable radiologically should also increase. We aimed to evaluate the potential clinical usefulness of 3-D phase-contrast micro-computed tomography (micro-CT) imaging at high spatial resolutions as an adjunct to conventional histological microscopy. Ten breast tissue specimens, 2 mm in diameter, were scanned at the SYRMEP beamline of the Elettra Synchrotron using the propagation-based phase-contrast micro-tomography method. We obtained pixel size images, which were analyzed and compared with corresponding histological sections examined under light microscopy. To evaluate the effect of spatial resolution on breast cancer diagnosis, scans with four different pixel sizes were also performed. Our comparative analysis revealed that high-resolution images can enable, at a near-histological level, detailed architectural assessment of tissue that may permit increased breast cancer diagnostic sensitivity and specificity when compared with current imaging practices. The potential clinical applications of this method are also discussed.
Collapse
|
31
|
High resolution laboratory grating-based X-ray phase-contrast CT. Sci Rep 2018; 8:15884. [PMID: 30367132 PMCID: PMC6203738 DOI: 10.1038/s41598-018-33997-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Accepted: 10/03/2018] [Indexed: 12/20/2022] Open
Abstract
The conventional form of computed tomography using X-ray attenuation without any contrast agents is of limited use for the characterization of soft tissue in many fields of medical and biological studies. Grating-based phase-contrast computed tomography (gbPC-CT) is a promising alternative imaging method solving the low soft tissue contrast without the need of any contrast agent. While highly sensitive measurements are possible using conventional X-ray sources the spatial resolution does often not fulfill the requirements for specific imaging tasks, such as visualization of pathologies. The focus of this study is the increase in spatial resolution without loss of sensitivity. To overcome this limitation a super-resolution reconstruction based on sub-pixel shifts involving a deconvolution of the image data during each iteration is applied. In our study we achieve an effective pixel size of 28 μm with a conventional rotating anode tube and a photon-counting detector. We also demonstrate that the method can upgrade existing setups to measure tomographies with higher resolution. The results show the increase in resolution at high sensitivity and with the ability to make quantitative measurements. The combination of sparse sampling and statistical iterative reconstruction may be used to reduce the total measurement time. In conclusion, we present high-quality and high-resolution tomographic images of biological samples to demonstrate the experimental feasibility of super-resolution reconstruction.
Collapse
|
32
|
Matsuda K, Lopez JCA, Rehman S, Misawa M, Suzuki Y, Takeuchi A, Yasumoto M, Hibino K, Roy M, Hanayama R, Ishii K. Differential interference contrast microscopy for cells using hard x-ray holography. APPLIED OPTICS 2018; 57:4795-4801. [PMID: 30118100 DOI: 10.1364/ao.57.004795] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Accepted: 05/15/2018] [Indexed: 06/08/2023]
Abstract
We propose a differential interference contrast method for cells using hard x-ray Gabor holography and knife-edge filtering in the spatial frequency domain, without relying on beam shearing. A phase object is holographically recorded and reconstructed by computer. Interference between the wavefronts of zeroth order weighted by ejπ/2 in the positive frequency region produces a dark image. Similarly, interference between the wavefronts of the zeroth order weighted by ej3π/2 in the negative frequency region produces a bright image. By adding these two intensity distributions, good quality phase-contrast images of 8-μm-diameter polystyrene beads and human HeLa cells were obtained.
Collapse
|
33
|
Lee H, Lim H, Jeon D, Park C, Lee D, Cho H, Seo C, Kim K, Kim G, Park S, Kang S, Park J, Kim W, Lim Y, Woo T. Eliminating artifacts in single-grid phase-contrast x-ray imaging for improving image quality. Comput Biol Med 2018; 97:74-82. [DOI: 10.1016/j.compbiomed.2018.04.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 04/03/2018] [Accepted: 04/19/2018] [Indexed: 10/17/2022]
|
34
|
Hauke C, Bartl P, Leghissa M, Ritschl L, Sutter SM, Weber T, Zeidler J, Freudenberger J, Mertelmeier T, Radicke M, Michel T, Anton G, Meinel FG, Baehr A, Auweter S, Bondesson D, Gaass T, Dinkel J, Reiser M, Hellbach K. A preclinical Talbot-Lau prototype for x-ray dark-field imaging of human-sized objects. Med Phys 2018; 45:2565-2571. [DOI: 10.1002/mp.12889] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 03/09/2018] [Accepted: 03/09/2018] [Indexed: 12/13/2022] Open
Affiliation(s)
- C. Hauke
- Siemens Healthcare GmbH; 91301 Forchheim Germany
- Erlangen Centre for Astroparticle Physics; FAU Erlangen-Nuremberg; 91058 Erlangen Germany
| | - P. Bartl
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - M. Leghissa
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - L. Ritschl
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - S. M. Sutter
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - T. Weber
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - J. Zeidler
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | | | | | - M. Radicke
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - T. Michel
- Erlangen Centre for Astroparticle Physics; FAU Erlangen-Nuremberg; 91058 Erlangen Germany
| | - G. Anton
- Erlangen Centre for Astroparticle Physics; FAU Erlangen-Nuremberg; 91058 Erlangen Germany
| | - F. G. Meinel
- Department of Diagnostic and Interventional Radiology; University of Rostock Medical Center; 18057 Rostock Germany
| | - A. Baehr
- Department of Veterinary Science; LMU Munich; 85764 Oberschleissheim Germany
| | - S. Auweter
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - D. Bondesson
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - T. Gaass
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - J. Dinkel
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - M. Reiser
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - K. Hellbach
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| |
Collapse
|
35
|
Vedantham S, Karellas A. Emerging Breast Imaging Technologies on the Horizon. Semin Ultrasound CT MR 2018; 39:114-121. [PMID: 29317033 DOI: 10.1053/j.sult.2017.09.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Early detection of breast cancers by mammography in conjunction with adjuvant therapy has contributed to reduction in breast cancer mortality. Mammography remains the "gold-standard" for breast cancer screening but is limited by tissue superposition. Digital breast tomosynthesis and more recently, dedicated breast computed tomography have been developed to alleviate the tissue superposition problem. However, all of these modalities rely upon x-ray attenuation contrast to provide anatomical images, and there are ongoing efforts to develop and clinically translate alternative modalities. These emerging modalities could provide for new contrast mechanisms and may potentially improve lesion detection and diagnosis. In this article, several of these emerging modalities are discussed with a focus on technologies that have advanced to the stage of in vivo clinical evaluation.
Collapse
Affiliation(s)
- Srinivasan Vedantham
- Department of Medical Imaging, University of Arizona College of Medicine, Banner University Medical Center, Tucson, AZ.
| | - Andrew Karellas
- Department of Medical Imaging, University of Arizona College of Medicine, Banner University Medical Center, Tucson, AZ
| |
Collapse
|
36
|
Marschner M, Birnbacher L, Willner M, Chabior M, Herzen J, Noël PB, Pfeiffer F. Revising the lower statistical limit of x-ray grating-based phase-contrast computed tomography. PLoS One 2017; 12:e0184217. [PMID: 28877253 PMCID: PMC5587302 DOI: 10.1371/journal.pone.0184217] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2016] [Accepted: 08/21/2017] [Indexed: 11/18/2022] Open
Abstract
Phase-contrast x-ray computed tomography (PCCT) is currently investigated as an interesting extension of conventional CT, providing high soft-tissue contrast even if examining weakly absorbing specimen. Until now, the potential for dose reduction was thought to be limited compared to attenuation CT, since meaningful phase retrieval fails for scans with very low photon counts when using the conventional phase retrieval method via phase stepping. In this work, we examine the statistical behaviour of the reverse projection method, an alternative phase retrieval approach and compare the results to the conventional phase retrieval technique. We investigate the noise levels in the projections as well as the image quality and quantitative accuracy of the reconstructed tomographic volumes. The results of our study show that this method performs better in a low-dose scenario than the conventional phase retrieval approach, resulting in lower noise levels, enhanced image quality and more accurate quantitative values. Overall, we demonstrate that the lower statistical limit of the phase stepping procedure as proposed by recent literature does not apply to this alternative phase retrieval technique. However, further development is necessary to overcome experimental challenges posed by this method which would enable mainstream or even clinical application of PCCT.
Collapse
Affiliation(s)
- Mathias Marschner
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748 Garching, Germany
- * E-mail:
| | - Lorenz Birnbacher
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748 Garching, Germany
| | - Marian Willner
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748 Garching, Germany
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, 81675 München, Germany
| | - Michael Chabior
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748 Garching, Germany
| | - Julia Herzen
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748 Garching, Germany
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, 81675 München, Germany
| | - Peter B. Noël
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748 Garching, Germany
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, 81675 München, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748 Garching, Germany
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, 81675 München, Germany
- Institute for Advanced Study, Technical University of Munich, 85748 Garching, Germany
| |
Collapse
|
37
|
Enhanced dynamic range x-ray imaging. Comput Biol Med 2017; 82:40-48. [PMID: 28160695 DOI: 10.1016/j.compbiomed.2017.01.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2016] [Revised: 01/18/2017] [Accepted: 01/23/2017] [Indexed: 11/23/2022]
Abstract
X-ray images can suffer from excess contrast. Often, image exposure is chosen to visually optimize the region of interest, but at the expense of over- and underexposed regions elsewhere in the image. When image values are interpreted quantitatively as projected absorption, both over- and underexposure leads to the loss of quantitative information. We propose to combine multiple exposures into a composite that uses only pixels from those exposures in which they are neither under- nor overexposed. The composite image is created in analogy to visible-light high dynamic range photography. We present the mathematical framework for the recovery of absorbance from such composite images and demonstrate the method with biological and non-biological samples. We also show with an aluminum step-wedge that accurate recovery of step thickness from the absorbance values is possible, thereby highlighting the quantitative nature of the presented method. Due to the higher amount of detail encoded in an enhanced dynamic range x-ray image, we expect that the number of retaken images can be reduced, and patient exposure overall reduced. We also envision that the method can improve dual energy absorptiometry and even computed tomography by reducing the number of low-exposure ("photon-starved") projections.
Collapse
|
38
|
Schröter TJ, Koch FJ, Meyer P, Kunka D, Meiser J, Willer K, Gromann L, De Marco F, Herzen J, Noel P, Yaroshenko A, Hofmann A, Pfeiffer F, Mohr J. Large field-of-view tiled grating structures for X-ray phase-contrast imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:015104. [PMID: 28147659 DOI: 10.1063/1.4973632] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
X-ray grating-based interferometry promises unique new diagnostic possibilities in medical imaging and materials analysis. To transfer this method from scientific laboratories or small-animal applications to clinical radiography applications, compact setups with a large field of view (FoV) are required. Currently the FoV is limited by the grating area, which is restricted due to the complex manufacturing process. One possibility to increase the FoV is tiling individual grating tiles to create one large area grating mounted on a carrier substrate. We investigate theoretically the accuracy needed for a tiling process in all degrees of freedom by applying a simulation approach. We show how the resulting precision requirements can be met using a custom-built frame for exact positioning. Precise alignment is achieved by comparing the fringe patterns of two neighboring grating tiles in a grating interferometer. With this method, the FoV can be extended to practically any desired length in one dimension. First results of a phase-contrast scanning setup with a full FoV of 384 mm × 24 mm show the suitability of this method.
Collapse
Affiliation(s)
- Tobias J Schröter
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Frieder J Koch
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Pascal Meyer
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Danays Kunka
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Jan Meiser
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Konstantin Willer
- Chair of Biomedical Physics, Department of Physics and Institute of Medical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Lukas Gromann
- Chair of Biomedical Physics, Department of Physics and Institute of Medical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Fabio De Marco
- Chair of Biomedical Physics, Department of Physics and Institute of Medical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Julia Herzen
- Chair of Biomedical Physics, Department of Physics and Institute of Medical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Peter Noel
- Chair of Biomedical Physics, Department of Physics and Institute of Medical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Andre Yaroshenko
- Chair of Biomedical Physics, Department of Physics and Institute of Medical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Andreas Hofmann
- Institute for Applied Computer Science, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics and Institute of Medical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Jürgen Mohr
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| |
Collapse
|
39
|
Marschner M, Birnbacher L, Mechlem K, Noichl W, Fehringer A, Willner M, Scherer K, Herzen J, Noël PB, Pfeiffer F. Two-shot X-ray dark-field imaging. OPTICS EXPRESS 2016; 24:27032-27045. [PMID: 27857430 DOI: 10.1364/oe.24.027032] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In this article, we report on a novel acquisition scheme for time- and dose-saving retrieval of dark-field data in grating-based phase-contrast imaging. In comparison to currently available techniques, the proposed approach only requires two phase steps. More importantly, our method is capable of accurately retrieving the dark-field signal where conventional approaches fail, for instance in the case of very low photon statistics. Finally, we successfully extend two-shot dark-field imaging to tomographic investigations, by implementing an iterative reconstruction with appropriate weights. Our results indicate an important progression towards the clinical feasibility of dark-field tomography.
Collapse
|
40
|
Marschner M, Willner M, Potdevin G, Fehringer A, Noël PB, Pfeiffer F, Herzen J. Helical X-ray phase-contrast computed tomography without phase stepping. Sci Rep 2016; 6:23953. [PMID: 27052368 PMCID: PMC4823776 DOI: 10.1038/srep23953] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2014] [Accepted: 03/17/2016] [Indexed: 01/15/2023] Open
Abstract
X-ray phase-contrast computed tomography (PCCT) using grating interferometry provides enhanced soft-tissue contrast. The possibility to use standard polychromatic laboratory sources enables an implementation into a clinical setting. Thus, PCCT has gained significant attention in recent years. However, phase-contrast CT scans still require significantly increased measurement times in comparison to conventional attenuation-based CT imaging. This is mainly due to a time-consuming stepping of a grating, which is necessary for an accurate retrieval of the phase information. In this paper, we demonstrate a novel scan technique, which directly allows the determination of the phase signal without a phase-stepping procedure. The presented work is based on moiré fringe scanning, which allows fast data acquisition in radiographic applications such as mammography or in-line product analysis. Here, we demonstrate its extension to tomography enabling a continuous helical sample rotation as routinely performed in clinical CT systems. Compared to standard phase-stepping techniques, the proposed helical fringe-scanning procedure enables faster measurements, an extended field of view and relaxes the stability requirements of the system, since the gratings remain stationary. Finally, our approach exceeds previously introduced methods by not relying on spatial interpolation to acquire the phase-contrast signal.
Collapse
Affiliation(s)
- M Marschner
- Lehrstuhl für Biomedizinische Physik, Physik-Department &Institut für Medizintechnik, Technische Universität München, 85748 Garching, Germany
| | - M Willner
- Lehrstuhl für Biomedizinische Physik, Physik-Department &Institut für Medizintechnik, Technische Universität München, 85748 Garching, Germany
| | - G Potdevin
- Lehrstuhl für Biomedizinische Physik, Physik-Department &Institut für Medizintechnik, Technische Universität München, 85748 Garching, Germany
| | - A Fehringer
- Lehrstuhl für Biomedizinische Physik, Physik-Department &Institut für Medizintechnik, Technische Universität München, 85748 Garching, Germany
| | - P B Noël
- Lehrstuhl für Biomedizinische Physik, Physik-Department &Institut für Medizintechnik, Technische Universität München, 85748 Garching, Germany.,Institut für diagnostische und interventionelle Radiologie, Klinikum rechts der Isar, Technische Universität München, 81675 München, Germany
| | - F Pfeiffer
- Lehrstuhl für Biomedizinische Physik, Physik-Department &Institut für Medizintechnik, Technische Universität München, 85748 Garching, Germany.,Institut für diagnostische und interventionelle Radiologie, Klinikum rechts der Isar, Technische Universität München, 81675 München, Germany
| | - J Herzen
- Lehrstuhl für Biomedizinische Physik, Physik-Department &Institut für Medizintechnik, Technische Universität München, 85748 Garching, Germany
| |
Collapse
|
41
|
Li P, Zhang K, Bao Y, Ren Y, Ju Z, Wang Y, He Q, Zhu Z, Huang W, Yuan Q, Zhu P. Angular signal radiography. OPTICS EXPRESS 2016; 24:5829-5845. [PMID: 27136780 DOI: 10.1364/oe.24.005829] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Microscopy techniques using visible photons, x-rays, neutrons, and electrons have made remarkable impact in many scientific disciplines. The microscopic data can often be expressed as the convolution of the spatial distribution of certain properties of the specimens and the inherent response function of the imaging system. The x-ray grating interferometer (XGI), which is sensitive to the deviation angle of the incoming x-rays, has attracted significant attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the comprehensive and analytical theoretical framework is yet to be presented. Herein, we propose a theoretical framework termed angular signal radiography (ASR) to describe the imaging process of the XGI system in a classical, comprehensive and analytical manner. We demonstrated, by means of theoretical deduction and synchrotron based experiments, that the spatial distribution of specimens' physical properties, including absorption, refraction and scattering, can be extracted by ASR in XGI. Implementation of ASR in XGI offers advantages such as simplified phase retrieval algorithm, reduced overall radiation dose, and improved image acquisition speed. These advantages, as well as the limitations of the proposed method, are systematically investigated in this paper.
Collapse
|
42
|
Meiser J, Willner M, Schröter T, Hofmann A, Rieger J, Koch F, Birnbacher L, Schüttler M, Kunka D, Meyer P, Faisal A, Amberger M, Duttenhofer T, Weber T, Hipp A, Ehn S, Walter M, Herzen J, Schulz J, Pfeiffer F, Mohr J. Increasing the field of view in grating based X-ray phase contrast imaging using stitched gratings. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2016; 24:379-388. [PMID: 27257876 DOI: 10.3233/xst-160552] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Grating based X-ray differential phase contrast imaging (DPCI) allows for high contrast imaging of materials with similar absorption characteristics. In the last years' publications, small animals or parts of the human body like breast, hand, joints or blood vessels have been studied. Larger objects could not be investigated due to the restricted field of view limited by the available grating area. In this paper, we report on a new stitching method to increase the grating area significantly: individual gratings are merged on a carrier substrate. Whereas the grating fabrication process is based on the LIGA technology (X-ray lithography and electroplating) different cutting and joining methods have been evaluated. First imaging results using a 2×2 stitched analyzer grating in a Talbot-Lau interferometer have been generated using a conventional polychromatic X-ray source. The image quality and analysis confirm the high potential of the stitching method to increase the field of view considerably.
Collapse
Affiliation(s)
- J Meiser
- Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany
| | - M Willner
- Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany
| | - T Schröter
- Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany
| | - A Hofmann
- Institute for Applied Computer Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - J Rieger
- Erlangen Center for Astroparticle Physics, Friedrich - Alexander - Universität Erlangen - Nürnberg, Erlangen, Germany
| | - F Koch
- Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany
| | - L Birnbacher
- Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany
| | - M Schüttler
- Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany
- Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany
| | - D Kunka
- Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany
| | - P Meyer
- Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany
| | - A Faisal
- Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany
| | - M Amberger
- Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany
| | | | - T Weber
- Erlangen Center for Astroparticle Physics, Friedrich - Alexander - Universität Erlangen - Nürnberg, Erlangen, Germany
| | - A Hipp
- Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany
- Institute of Materials Research, Helmholtz-Zentrum Geesthacht, Geesthacht, Germany
| | - S Ehn
- Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany
| | - M Walter
- Microworks GmbH, Karlsruhe, Germany
| | - J Herzen
- Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany
| | - J Schulz
- Microworks GmbH, Karlsruhe, Germany
| | - F Pfeiffer
- Department of Physics and Institute of Medical Engineering, Technische Universität München, Garching, Germany
| | - J Mohr
- Institute of Microstructure Technology, Karlsruhe Institute of Technology Eggenstein-Leopoldshafen, Germany
| |
Collapse
|
43
|
Frølich S, Leemreize H, Jakus A, Xiao X, Shah R, Birkedal H, Almer JD, Stock SR. Diffraction tomography and Rietveld refinement of a hydroxyapatite bone phantom. J Appl Crystallogr 2016. [DOI: 10.1107/s1600576715022633] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
A model sample consisting of two different hydroxyapatite (hAp) powders was used as a bone phantom to investigate the extent to which X-ray diffraction tomography could map differences in hAp lattice constants and crystallite size. The diffraction data were collected at beamline 1-ID, the Advanced Photon Source, using monochromatic 65 keV X-radiation, a 25 × 25 µm pinhole beam and translation/rotation data collection. The diffraction pattern was reconstructed for each volume element (voxel) in the sample, and Rietveld refinement was used to determine the hAp lattice constants. The crystallite size for each voxel was also determined from the 00.2 hAp diffraction peak width. The results clearly show that differences between hAp powders could be measured with diffraction tomography.
Collapse
|
44
|
AHA classification of coronary and carotid atherosclerotic plaques by grating-based phase-contrast computed tomography. Eur Radiol 2015; 26:3223-33. [PMID: 26679184 DOI: 10.1007/s00330-015-4143-z] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2015] [Revised: 07/20/2015] [Accepted: 11/30/2015] [Indexed: 10/22/2022]
Abstract
OBJECTIVES To evaluate the potential of grating-based phase-contrast computed-tomography (gb-PCCT) to classify human carotid and coronary atherosclerotic plaques according to modified American Heart Association (AHA) criteria. METHODS Experiments were carried out at a laboratory-based set-up consisting of X-ray tube (40 kVp), grating-interferometer and detector. Eighteen human carotid and coronary artery specimens were examined. Histopathology served as the standard of reference. Vessel cross-sections were classified as AHA lesion type I/II, III, IV/V, VI, VII or VIII plaques by two independent reviewers blinded to histopathology. Conservative measurements of diagnostic accuracies for the detection and differentiation of plaque types were evaluated. RESULTS A total of 127 corresponding gb-PCCT/histopathology sections were analyzed. Based on histopathology, lesion type I/II was present in 12 (9.5 %), III in 18 (14.2 %), IV/V in 38 (29.9 %), VI in 16 (12.6 %), VII in 34 (26.8 %) and VIII in 9 (7.0 %) cross-sections. Sensitivity, specificity and positive and negative predictive value were ≥0.88 for most analyzed plaque types with a good level of agreement (Cohen's kappa = 0.90). Overall, results were better in carotid (kappa = 0.97) than in coronary arteries (kappa = 0.85). Inter-observer agreement was high with kappa = 0.85, p < 0.0001. CONCLUSIONS These results indicate that gb-PCCT can reliably classify atherosclerotic plaques according to modified AHA criteria with excellent agreement to histopathology. KEY POINTS • Different atherosclerotic plaque types display distinct morphological features in phase-contrast CT. • Phase-contrast CT can detect and differentiate AHA plaque types. • Calcifications caused streak artefacts and reduced sensitivity in type VI lesions. • Overall agreement was higher in carotid than in coronary arteries.
Collapse
|
45
|
Koch FJ, Schröter TJ, Kunka D, Meyer P, Meiser J, Faisal A, Khalil MI, Birnbacher L, Viermetz M, Walter M, Schulz J, Pfeiffer F, Mohr J. Note: Gratings on low absorbing substrates for x-ray phase contrast imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:126114. [PMID: 26724095 DOI: 10.1063/1.4939055] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Grating based X-ray phase contrast imaging is on the verge of being applied in clinical settings. To achieve this goal, compact setups with high sensitivity and dose efficiency are necessary. Both can be increased by eliminating unwanted absorption in the beam path, which is mainly due to the grating substrates. Fabrication of gratings via deep X-ray lithography can address this issue by replacing the commonly used silicon substrate with materials with lower X-ray absorption that fulfill certain boundary conditions. Gratings were produced on both graphite and polymer substrates without compromising on structure quality. These gratings were tested in a three-grating setup with a source operated at 40 kVp and lead to an increase in the detector photon count rate of almost a factor of 4 compared to a set of gratings on silicon substrates. As the visibility was hardly affected, this corresponds to a significant increase in sensitivity and therefore dose efficiency.
Collapse
Affiliation(s)
- F J Koch
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - T J Schröter
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - D Kunka
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - P Meyer
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - J Meiser
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - A Faisal
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - M I Khalil
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| | - L Birnbacher
- Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, Munich, Germany
| | - M Viermetz
- Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, Munich, Germany
| | - M Walter
- Microworks GmbH, Karlsruhe, Germany
| | - J Schulz
- Microworks GmbH, Karlsruhe, Germany
| | - F Pfeiffer
- Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, Munich, Germany
| | - J Mohr
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
| |
Collapse
|
46
|
Hipp A, Willner M, Herzen J, Auweter S, Chabior M, Meiser J, Achterhold K, Mohr J, Pfeiffer F. Energy-resolved visibility analysis of grating interferometers operated at polychromatic X-ray sources. OPTICS EXPRESS 2014; 22:30394-30409. [PMID: 25606986 DOI: 10.1364/oe.22.030394] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Grating interferometry has been successfully adapted at standard X-ray tubes and is a promising candidate for a broad use of phase-contrast imaging in medical diagnostics or industrial testing. The achievable image quality using this technique is mainly dependent on the interferometer performance with the interferometric visibility as crucial parameter. The presented study deals with experimental investigations of the spectral dependence of the visibility in order to understand the interaction between the single contributing energies. Especially for the choice which type of setup has to be preferred using a polychromatic source, this knowledge is highly relevant. Our results affirm previous findings from theoretical investigations but also show that measurements of the spectral contributions to the visibility are necessary to fully characterize and optimize a grating interferometer and cannot be replaced by only relying on simulated data up to now.
Collapse
|
47
|
Yang Y, Tang X. Complex dark-field contrast and its retrieval in x-ray phase contrast imaging implemented with Talbot interferometry. Med Phys 2014; 41:101914. [PMID: 25281966 DOI: 10.1118/1.4896098] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Under the existing theoretical framework of x-ray phase contrast imaging methods implemented with Talbot interferometry, the dark-field contrast refers to the reduction in interference fringe visibility due to small-angle x-ray scattering of the subpixel microstructures of an object to be imaged. This study investigates how an object's subpixel microstructures can also affect the phase of the intensity oscillations. METHODS Instead of assuming that the object's subpixel microstructures distribute in space randomly, the authors' theoretical derivation starts by assuming that an object's attenuation projection and phase shift vary at a characteristic size that is not smaller than the period of analyzer grating G₂ and a characteristic length dc. Based on the paraxial Fresnel-Kirchhoff theory, the analytic formulae to characterize the zeroth- and first-order Fourier coefficients of the x-ray irradiance recorded at each detector cell are derived. Then the concept of complex dark-field contrast is introduced to quantify the influence of the object's microstructures on both the interference fringe visibility and the phase of intensity oscillations. A method based on the phase-attenuation duality that holds for soft tissues and high x-ray energies is proposed to retrieve the imaginary part of the complex dark-field contrast for imaging. Through computer simulation study with a specially designed numerical phantom, they evaluate and validate the derived analytic formulae and the proposed retrieval method. RESULTS Both theoretical analysis and computer simulation study show that the effect of an object's subpixel microstructures on x-ray phase contrast imaging method implemented with Talbot interferometry can be fully characterized by a complex dark-field contrast. The imaginary part of complex dark-field contrast quantifies the influence of the object's subpixel microstructures on the phase of intensity oscillations. Furthermore, at relatively high energies, for soft tissues it can be retrieved for imaging with a method based on the phase-attenuation duality. CONCLUSIONS The analytic formulae derived in this work to characterize the complex dark-field contrast in x-ray phase contrast imaging method implemented with Talbot interferometry are of significance, which may initiate more activities in the research and development of x-ray differential phase contrast imaging for extensive biomedical applications.
Collapse
Affiliation(s)
- Yi Yang
- Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Drive, C-5018, Atlanta, Georgia 30322
| | - Xiangyang Tang
- Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Drive, C-5018, Atlanta, Georgia 30322
| |
Collapse
|
48
|
Millard TP, Endrizzi M, Diemoz PC, Hagen CK, Olivo A. Monte Carlo model of a polychromatic laboratory based edge illumination x-ray phase contrast system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:053702. [PMID: 24880377 DOI: 10.1063/1.4873328] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A Monte Carlo model of a polychromatic laboratory based (coded aperture) edge illumination x-ray phase contrast imaging system has been developed and validated against experimental data. The ability for the simulation framework to be used to model two-dimensional images is also shown. The Monte Carlo model has been developed using the McXtrace engine and is polychromatic, i.e., results are obtained through the use of the full x-ray spectrum rather than an effective energy. This type of simulation can in future be used to model imaging of objects with complex geometry, for system prototyping, as well as providing a first step towards the development of a simulation for modelling dose delivery as a part of translating the imaging technique for use in clinical environments.
Collapse
Affiliation(s)
- T P Millard
- Department of Medical Physics and Bioengineering, University College London, Malet Place, Gower Street, London WC1E 6BT, United Kingdom
| | - M Endrizzi
- Department of Medical Physics and Bioengineering, University College London, Malet Place, Gower Street, London WC1E 6BT, United Kingdom
| | - P C Diemoz
- Department of Medical Physics and Bioengineering, University College London, Malet Place, Gower Street, London WC1E 6BT, United Kingdom
| | - C K Hagen
- Department of Medical Physics and Bioengineering, University College London, Malet Place, Gower Street, London WC1E 6BT, United Kingdom
| | - A Olivo
- Department of Medical Physics and Bioengineering, University College London, Malet Place, Gower Street, London WC1E 6BT, United Kingdom
| |
Collapse
|
49
|
Pelliccia D, Paganin DM. Multi-modal hard x-ray imaging with a laboratory source using selective reflection from a mirror. BIOMEDICAL OPTICS EXPRESS 2014; 5:1153-1159. [PMID: 24761297 PMCID: PMC3985998 DOI: 10.1364/boe.5.001153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2014] [Revised: 03/08/2014] [Accepted: 03/10/2014] [Indexed: 06/03/2023]
Abstract
Multi-modal hard x-ray imaging sensitive to absorption, refraction, phase and scattering contrast is demonstrated using a simple setup implemented with a laboratory source. The method is based on selective reflection at the edge of a mirror, aligned to partially reflect a pencil x-ray beam after its interaction with a sample. Quantitative scattering contrast from a test sample is experimentally demonstrated using this method. Multi-modal imaging of a house fly (Musca domestica) is shown as proof of principle of the technique for biological samples.
Collapse
|
50
|
Sarapata A, Stayman JW, Finkenthal M, Siewerdsen JH, Pfeiffer F, Stutman D. High energy x-ray phase contrast CT using glancing-angle grating interferometers. Med Phys 2014; 41:021904. [PMID: 24506625 PMCID: PMC3981561 DOI: 10.1118/1.4860275] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2013] [Revised: 12/10/2013] [Accepted: 12/17/2013] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. METHODS DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. RESULTS Using a glancing angle interferometer at high x-ray energy (∼ 45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. CONCLUSIONS DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.
Collapse
Affiliation(s)
- A Sarapata
- Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218 and Department of Physics and Institute of Medical Engineering, Technische Universität München, 85748 Garching, Germany
| | - J W Stayman
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21218
| | - M Finkenthal
- Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218
| | - J H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21218
| | - F Pfeiffer
- Department of Physics and Institute of Medical Engineering, Technische Universität München, 85748 Garching, Germany
| | - D Stutman
- Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218
| |
Collapse
|