1
|
Recent progress on developing of plasmon biosensing of tumor biomarkers: Efficient method towards early stage recognition of cancer. Biomed Pharmacother 2020; 132:110850. [PMID: 33068930 DOI: 10.1016/j.biopha.2020.110850] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 09/21/2020] [Accepted: 10/04/2020] [Indexed: 12/18/2022] Open
Abstract
Cancer is the second most extended disease with an improved death rate over the past several time. Due to the restrictions of cancer analysis methods, the patient's real survival rate is unknown. Therefore, early stage diagnosis of cancer is crucial for its strong detection. Bio-analysis based on biomarkers may help to overcome the problem Biosensors with high sensitivity and specificity, low-cost, high analysis speed and minimum limit of detection are practical alternatives for laboratory tests. Surface plasmon resonance (SPR) is reaching a maturity level sufficient for their application in detection and determination cancer biomarkers in clinical samples. This review discusses main concepts and performance characteristics of SPR biosensor. Mainly, it focuses on newly emerged enhanced SPR biosensors towards high-throughput and ultrasensitive screening of cancer biomarkers such as PSA, α-fetoprotein, CEA, CA125, CA 15-3, HER2, ctDNA, ALCAM, hCG, VEGF, TNF, Interleukin, IFN-γ, CD24, CD44, Ferritin, COLIV using labeling processes with focusing on the future application in biomedical research and clinical diagnosis. This article reviews current status of the field, showcasing a series of early successes in the application of SPR for clinical bioanalysis of cancer related biomolecules and detailing a series of considerations regarding sensing schemes, exposing issues with analysis in biofluids, while providing an outlook of the challenges currently associated with plasmonic materials, bioreceptor selection, microfluidics, and validation of a clinical bioassay for applying SPR biosensors to clinical samples. Research opportunities are proposed to further advance the field and transition SPR biosensors from research proof-of-concept stage to actual clinical usage.
Collapse
|
2
|
Stability of Polydopamine Coatings on Gold Substrates Inspected by Surface Plasmon Resonance Imaging. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2018; 34:3565-3571. [PMID: 29505722 DOI: 10.1021/acs.langmuir.7b03143] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Polydopamine (PDA)-based surface modification has been used in a variety of fields. However, a vague impression on the stability of PDA still exists due to a lack of systematic studies. To ascertain the issue and make better use of this surface modification method, a technique of surface plasmon resonance imaging (SPRi) was exploited to study the stability of PDA coated on gold surface. The results showed that PDA-coating stability was largely dependent on the pH of aqueous solutions, giving detachment ratios up to 66% and 80% at pH 1.0 and pH 14.0, respectively. However, increasing the ionic strength of aqueous solutions could reduce the detachment of PDA in strong acid and strong alkali conditions. Besides, organic solvents also made a difference on the PDA-coating stability. Among the tested 10 kinds of organic solvents, including n-hexane, toluene, ethyl ether, tetrahydrofuran, ethyl acetate, isopropanol, acetone, acetonitrile, dimethylformamide (DMF), and dimethyl sulfoxide (DMSO), DMSO caused the most serious detachment of PDA, up to 56%, followed by DMF with a detachment ratio of 31%. Ultrasonication caused less than 10% detachment of the coated PDA. It should be mentioned that the PDA coatings deposited on gold surface were not detached completely in all the test conditions, even at pH 14.0 (ca. 20% PDA retained). In alkaline conditions, detachment competes with further polymerization, which gave a slight increase of the SPRi signals at pH 9.0-11.0. Based on the obtained information about PDA-coating stability, thickness-controllable and alkali-resistant PDA coatings were prepared. Moreover, the alkali-resistant PDA coatings remained reactive to biomolecules, supporting further functionalization of PDA coatings.
Collapse
|
3
|
Multiplex Surface Plasmon Resonance Imaging-Based Biosensor for Human Pancreatic Islets Hormones Quantification. Anal Chem 2018; 90:3132-3139. [DOI: 10.1021/acs.analchem.7b04288] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
4
|
Optimization of 3D Surfaces of Dextran with Different Molecule Weights for Real-Time Detection of Biomolecular Interactions by a QCM Biosensor. Polymers (Basel) 2017; 9:E409. [PMID: 30965713 PMCID: PMC6418631 DOI: 10.3390/polym9090409] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 08/25/2017] [Accepted: 08/29/2017] [Indexed: 02/05/2023] Open
Abstract
Quartz crystal microbalance (QCM) has been extensively applied in real-time and label-free biomolecular interaction studies. However, the sensitive detection by QCM technology remains challenging, mainly due to the limited surface immobilization capacity. Here, a three-dimensional (3D) carboxymethyl dextran coated gold sensor chip surface was successfully fabricated with dextran of different molecular weight (100, 500 and 2000 kDa, respectively). To evaluate the 3D carboxymethyl dextran surface immobilization capacity, the 3D surface was used for studying antigen⁻antibody interactions on the QCM biosensor. The results showed that the protein immobilization capacity of the 3D carboxymethyl dextran (2000 kDa) surface exceeded more than 4 times the capacity of the 2D carboxyl surface, and 2 times the capacity of the traditional 3D carboxymethyl dextran (500 kDa) surface. Furthermore, the kinetic and affinity properties of antigen⁻antibody interactions were performed. Most notably, the optimized 3D carboxymethyl dextran (2000 kDa) surface could be used for small molecule detection, where the binding of biotinylated oligo (0.67 kDa) reached 8.1 Hz. The results confirmed that a 3D carboxymethyl dextran (2000 kDa) surface can be exploited for sensitive detection of low molecular weight analytes, which have great potential applications for characterizing the interactions between small molecule drugs and proteins.
Collapse
|
5
|
A versatile microparticle-based immunoaggregation assay for macromolecular biomarker detection and quantification. PLoS One 2015; 10:e0115046. [PMID: 25658837 PMCID: PMC4319848 DOI: 10.1371/journal.pone.0115046] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Accepted: 11/18/2014] [Indexed: 12/13/2022] Open
Abstract
The rapid, sensitive and low-cost detection of macromolecular biomarkers is critical in clinical diagnostics, environmental monitoring, research, etc. Conventional assay methods usually require bulky, expensive and designated instruments and relative long assay time. For hospitals and laboratories that lack immediate access to analytical instruments, fast and low-cost assay methods for the detection of macromolecular biomarkers are urgently needed. In this work, we developed a versatile microparticle (MP)-based immunoaggregation method for the detection and quantification of macromolecular biomarkers. Antibodies (Abs) were firstly conjugated to MP through streptavidin-biotin interaction; the addition of macromolecular biomarkers caused the aggregation of Ab-MPs, which were subsequently detected by an optical microscope or optical particle sizer. The invisible nanometer-scale macromolecular biomarkers caused detectable change of micrometer-scale particle size distributions. Goat anti-rabbit immunoglobulin and human ferritin were used as model biomarkers to demonstrate MP-based immunoaggregation assay in PBS and 10% FBS to mimic real biomarker assay in the complex medium. It was found that both the number ratio and the volume ratio of Ab-MP aggregates caused by biomarker to all particles were directly correlated to the biomarker concentration. In addition, we found that the detection range could be tuned by adjusting the Ab-MP concentration. We envision that this novel MP-based immunoaggregation assay can be combined with multiple detection methods to detect and quantify macromolecular biomarkers at the nanogram per milliliter level.
Collapse
|
6
|
Label-free detection of Pb2+ based on aggregation-induced emission enhancement of Au-nanoclusters. RSC Adv 2015. [DOI: 10.1039/c5ra03449c] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The luminescence intensity of the glutathione capped Au-nanoclusters could be enhanced due to the formation of aggregates, and was employed for the visual detection of Pb2+.
Collapse
|
7
|
Surface plasmon resonance immunoassay for the detection of the TNFα biomarker in human serum. Talanta 2013; 119:492-7. [PMID: 24401446 DOI: 10.1016/j.talanta.2013.11.063] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2013] [Revised: 11/20/2013] [Accepted: 11/23/2013] [Indexed: 11/15/2022]
Abstract
A simple method for the detection of TNF-alpha protein biomarker in human serum with great sensitivity has been developed using a surface plasmon resonance biosensor. Signal amplification based on a sandwich immunoassay including gold nanoparticles was used. Detection in serum proved to be challenging due to high undesirable non-specific binding to the sensor surface stemming from the matrix nature of the sample. After optimization of the assay parameters and, in the case of serum, of a sample dilution buffer to minimize the non-specific binding, very low limits of detection were achieved: 11.6 pg/mL (211 fM) and 54.4 pg/mL (989 fM) for spiked buffer and human serum respectively. The amplification steps with high affinity biotinylated antibodies and streptavidin-fuctionalized nanoparticles greatly enhanced the signal with the advantage of additional specificity. Due to its simplicity and sensitivity, the immunoassay has proved feasible to be used for detection of low concentration biomarkers in real samples.
Collapse
|
8
|
Recent developments and applications of surface plasmon resonance biosensors for the detection of mycotoxins in foodstuffs. Food Chem 2012; 132:1549-1554. [DOI: 10.1016/j.foodchem.2011.10.109] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2010] [Revised: 06/16/2011] [Accepted: 10/29/2011] [Indexed: 11/20/2022]
|
9
|
Demonstration of near infrared gas sensing using gold nanodisks on functionalized silicon. OPTICS EXPRESS 2011; 19:7664-7672. [PMID: 21503075 DOI: 10.1364/oe.19.007664] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
In this work, we demonstrate experimentally the use of an array of gold nanodisks on functionalized silicon for chemosensing purposes. The metallic nanostructures are designed to display a very strong plasmonic resonance in the infrared regime, which results in highly sensitive sensing. Unlike usual experiments which are based on the functionalization of the metal surface, we functionalized here the silicon substrate. This silicon surface was modified chemically by buildup of an organosilane self-assembled monolayer (SAM) containing isocyanate as functional group. These groups allow for an easy surface regeneration by simple heating, thanks to the thermally reversible interaction isocyanate-analyte, which allows the cyclic use of the sensor. The technique showed a high sensitivity to surface binding events in gas and allowed the surface regeneration by heating of the sensor at 150 °C. A relative wavelength shift ∆λ(max)λ(0)=0.027 was obtained when the saturation level was reached.
Collapse
|
10
|
Carbon nanotube-assisted enhancement of surface plasmon resonance signal. Anal Biochem 2011; 408:206-11. [DOI: 10.1016/j.ab.2010.09.026] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2010] [Revised: 08/01/2010] [Accepted: 09/17/2010] [Indexed: 10/19/2022]
|
11
|
Sensitive and selective detection of mycoplasma in cell culture samples using cantilever sensors. Biotechnol Bioeng 2010; 105:1069-77. [PMID: 20014143 DOI: 10.1002/bit.22637] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this article we report a new biosensor-based method that is more sensitive and rapid than the current approach for detecting mycoplasma in cell culture samples. Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors respond to mass change via resonant frequency change. They are sensitive at femtogram level and can be used directly in liquid for label-free detection. Common cell culture contaminant, Acholeplasma laidlawii was detected in both buffer and cell culture medium. Two different sources (positive control from a commercial kit and ATCC 23206) were analyzed using antibody-immobilized PEMC sensor. Resonant frequency decrease caused by binding of A. laidlawii was monitored in real-time using an impedance analyzer. Positive detection was confirmed by a second antibody binding. The limit of detection (LOD) was lower than 10(3) CFU/mL in cell culture medium using PEMC sensor while parallel ELISA assays showed LOD as 10(7) CFU/mL. This study shows that PEMC sensor can be used for sensitive and rapid mycoplasma detection in cell culture samples.
Collapse
|
12
|
A rapid method for detection of PrP by surface plasmon resonance (SPR). Arch Virol 2009; 154:1901-8. [DOI: 10.1007/s00705-009-0532-4] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2009] [Accepted: 09/29/2009] [Indexed: 12/21/2022]
|
13
|
Rapid and label-free bacteria detection by surface plasmon resonance (SPR) biosensors. Biotechnol J 2009; 4:1003-11. [PMID: 19288516 DOI: 10.1002/biot.200800316] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Surface Plasmon Resonance (SPR) biosensor technology has been successfully used for the detection of various analytes such as proteins, drugs, DNA, and microorganisms. SPR-based immunosensors that coupled with a specific antigen-antibody reaction, have become a promising tool for the quantification of bacteria as it offers sensitive, specific, rapid, and label-free detection. In this paper, we review the important issues in the development of SPR-based immunoassays for bacteria detection, concentrating on instrumentation, surface functionalization, liquid handling, and surface regeneration. In addition, this review touches on the recent advances in SPR biosensing for sensitivity enhancement.
Collapse
|
14
|
Surface plasmon resonance biosensor for direct detection of antibodies against human growth hormone. Analyst 2009; 134:2051-7. [DOI: 10.1039/b907315a] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
15
|
Screening of High-Affinity scFvs From a Ribosome Displayed Library Using BIAcore Biosensor. Appl Biochem Biotechnol 2008; 152:224-34. [DOI: 10.1007/s12010-008-8251-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2007] [Accepted: 04/18/2008] [Indexed: 10/21/2022]
|
16
|
Detection of human proteins using arrayed imaging reflectometry. Biosens Bioelectron 2008; 24:334-7. [PMID: 18599284 DOI: 10.1016/j.bios.2008.05.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2008] [Revised: 05/06/2008] [Accepted: 05/20/2008] [Indexed: 11/17/2022]
Abstract
Assays built upon protein arrays are critical tools in determining the basic nature of biology, and have considerable promise in diagnosing human disease. These protein arrays aid in the elucidation of mapping pathway interactions, disease biomarker discovery, and regulatory processes. The solutions used in these experiments, including cellular lysate and serum, are inherently complex mixtures and are high in total protein content. Therefore, array-based assays must be robust and maintain a high level of selectivity and sensitivity. We report herein that arrayed imaging reflectometry (AIR), a label-free biosensing platform we have previously disclosed, is highly suitable for the detection of human proteins in complex solutions. In particular, we demonstrate array-based detection of cytokines in buffered solutions, and in undiluted human serum.
Collapse
|
17
|
Colloidal-based localized surface plasmon resonance (LSPR) biosensor for the quantitative determination of stanozolol. Anal Bioanal Chem 2008; 391:1813-20. [DOI: 10.1007/s00216-008-2022-z] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2007] [Revised: 02/13/2008] [Accepted: 02/22/2008] [Indexed: 12/01/2022]
|
18
|
Anti-rabbit immunoglobulin G detection in complex medium by PM-RAIRS and QCM. Biosens Bioelectron 2007; 22:2884-90. [PMID: 17229565 DOI: 10.1016/j.bios.2006.12.009] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2006] [Revised: 11/28/2006] [Accepted: 12/01/2006] [Indexed: 11/20/2022]
Abstract
Two antibody immobilisation procedures were compared to set up an immunosensor for goat anti-rabbit immunoglobulin (anti-rIgG), i.e. rIgG covalently bound or immobilised via affinity to protein A (PrA). In both cases, the first layer of protein was covalently bound to a mixed self-assembled monolayer (SAM) of mercaptoundecanoic acid (MUA) and mercaptohexanol (C6OH) on a gold surface. The elaboration of the sensitive surfaces, as well as their selectivity and sensitivity were studied step by step by polarization modulation-reflection absorption infra-red spectroscopy (PM-RAIRS) and quartz crystal microbalance (QCM) with impedance measurement. QCM measurements showed that the viscoelastic properties of the antibody layer were markedly modified during the antigen recognition when the antibody was bound by affinity to PrA. The specific detection of antigen within a complex medium was assessed by PM-RAIRS thanks to the grafting of cobalt-carbonyl probes. Affinity constants between the immobilised rIgG and the anti-rIgG were determined from PM-RAIRS analysis.
Collapse
|
19
|
Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin. Biosens Bioelectron 2007; 22:1382-9. [PMID: 16870423 DOI: 10.1016/j.bios.2006.06.012] [Citation(s) in RCA: 122] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2006] [Revised: 06/08/2006] [Accepted: 06/15/2006] [Indexed: 11/26/2022]
Abstract
A simple and rapid continuous-flow immunosensor based on surface plasmon resonance (SPR) has been developed for detection of insulin as low as 1 ng ml-1 (ppb) with a response time of less than 5 min. At first, a heterobifunctional oligo(ethyleneglycol)-dithiocarboxylic acid derivative (OEG-DCA) containing dithiol and carboxyl end groups was used to functionalize the thin Au-film of SPR chip. Insulin was covalently bound to the Au-thiolate monolayer of OEG-DCA for activating the sensor surface to immunoaffinity interactions. An on-line competitive immunosensing principle is examined for detection of insulin, in which the direct affinity binding of anti-insulin antibody to the insulin on sensor surface is examined in the presence and absence of various concentrations of insulin. Immunoreaction of anti-insulin antibody with the sensor surface was optimized with reference to antibody concentration, sample analysis time and flow-rate to provide the desired detection limit and determination range. With the immunosensor developed, the lowest detectable concentration of insulin is 1 ng ml-1 and the determination range covers a wide concentration of 1-300 ng ml-1. The developed OEG-monolayer based sensor chip exhibited high resistance to non-specific adsorption of proteins, and an uninterrupted highly sensitive detection of insulin from insulin-impregnated serum samples has been demonstrated. After an immunoreaction cycle, active sensor surface was regenerated simply by a brief flow of an acidic buffer (glycine.HCl; pH 2.0) for less than 1 min. A same sensor chip was found reusable for more than 25 cycles without an appreciable change in the original sensor activity.
Collapse
|
20
|
A strategy for sensitivity and specificity enhancements in prostate specific antigen-α1-antichymotrypsin detection based on surface plasmon resonance. Biosens Bioelectron 2006; 21:2106-13. [PMID: 16310353 DOI: 10.1016/j.bios.2005.10.014] [Citation(s) in RCA: 118] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2005] [Revised: 10/05/2005] [Accepted: 10/17/2005] [Indexed: 11/27/2022]
Abstract
A biochip based on surface plasmon resonance was fabricated to detect prostate specific antigen-alpha(1)-antichymotrypsin (PSA-ACT complex) in both HBS buffer and human serum. To reduce non-specific binding and steric hindrance effect, the chemical surface of the sensor chips was constructed by using various oligo(ethylene glycol) mixtures of different molar ratios of HS(CH2)11(OCH2CH2)6OCH2COOH and HS(CH2)11(OCH2CH2)3OH. The self-assembled monolayers were biotinylated to facilitate the immobilization of streptavidin. Using the chip surfaces, PSA-ACT complex in HBS buffer and human serum was detected at 20.7 and 47.5 ng/ml by primary immunoresponse, respectively. However, the limit of detection could be simply enhanced by a sandwich strategy to improve the sensitivity and specificity of the immunoassay. An intact PSA polyclonal antibody was used as an amplifying agent in the strategy. As a result, PSA-ACT complex concentrations as low as 10.2 and 18.1 ng/ml were found in the HBS buffer and human serum sample, respectively. The result indicates that this approach could satisfy our goal without modifying the secondary interactant.
Collapse
|
21
|
Quantitative detection of doping substances by a localised surface plasmon sensor. Biosens Bioelectron 2006; 21:1345-9. [PMID: 15935632 DOI: 10.1016/j.bios.2005.04.019] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2005] [Revised: 04/18/2005] [Accepted: 04/29/2005] [Indexed: 10/25/2022]
Abstract
Within this communication, consistent evidence of a quantitative biosensing principle for steroidal residue analysis is presented. Our approach uses a simple method for the quantitative determination of an anabolic agent called stanozolol (Sz). Sz (Mw 328) is widely used in sports, horse racing and as a growth promoter in animals for human consumption. Through the use of localised surface plasmons (LSPs), sustained by three-dimensional noble metal nanostructures, we have developed a highly specific, label-less immunosensor for the detection of this small organic molecule to low levels (nM range). A main practical advantage over conventional flat extended film surface plasmon resonance (SPR) systems is the simplicity of the optical configuration, since there is no need for cumbersome total internal reflection illumination, thus making integration easier. In addition, the active area of the LSP-based sensor is smaller, decreasing the minimum detectable number of molecules involved in the binding event. Assay times are short and the set-up is comprised of relatively cheap instrumentation. Detection levels found here are comparable with SPR, even at this early stage of development and with further modifications, we envisage sensing down to pM (10(-12)) levels.
Collapse
|
22
|
Determination of lactoferrin in bovine milk, colostrum and infant formulas by optical biosensor analysis. Int Dairy J 2005. [DOI: 10.1016/j.idairyj.2004.09.003] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
23
|
Enhanced sensitivity of surface plasmon resonance (SPR) immunoassays using a peroxidase-catalyzed precipitation reaction and its application to a protein microarray. J Immunol Methods 2005; 297:125-32. [PMID: 15777936 DOI: 10.1016/j.jim.2004.12.007] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2004] [Revised: 11/30/2004] [Accepted: 12/01/2004] [Indexed: 11/15/2022]
Abstract
We describe a method to improve the sensitivity of surface plasmon resonance (SPR) immunoassays using a horseradish peroxidase (HRP)-catalyzed precipitation reaction. The precipitation reaction catalyzed by HRP bound to the SPR biosensor surface via a sandwich immunoassay induced a shift in the SPR angle. Human interferon (IFN)-gamma at concentrations ranging from 0.01 to 100 ng/ml was detectable by this method. We also show that this biocatalytic signal amplification method can be applied to SPR imaging (SPRI), in an immunoassay of multiple proteins on a protein microarray format.
Collapse
|
24
|
A Novel Method for Determination of Cattle Bovine Ephemeral Fever Virus in Liquid with Quartz Crystal Microbalance Immunosensor. ANAL LETT 2005. [DOI: 10.1081/al-200045133] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
25
|
Abstract
In the year 2003 there was a 17% increase in the number of publications citing work performed using optical biosensor technology compared with the previous year. We collated the 962 total papers for 2003, identified the geographical regions where the work was performed, highlighted the instrument types on which it was carried out, and segregated the papers by biological system. In this overview, we spotlight 13 papers that should be on everyone's 'must read' list for 2003 and provide examples of how to identify and interpret high-quality biosensor data. Although we still find that the literature is replete with poorly performed experiments, over-interpreted results and a general lack of understanding of data analysis, we are optimistic that these shortcomings will be addressed as biosensor technology continues to mature.
Collapse
|
26
|
Nanoparticle labels in immunosensing using optical detection methods. Biosens Bioelectron 2004; 20:2454-69. [PMID: 15854819 DOI: 10.1016/j.bios.2004.11.003] [Citation(s) in RCA: 210] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2004] [Revised: 11/04/2004] [Accepted: 11/04/2004] [Indexed: 10/26/2022]
Abstract
Efforts to improve the performance of immunoassays and immunosensors by incorporating different kinds of nanostructures have gained considerable momentum over the last decade. Apart from liposomes, which will not be discussed here, most groups focus on artificial, particulate marker systems, both organic and inorganic. The underlying detection procedures may be based either on electro-magnetical or optical techniques. This review will be confined to the latter only, comprising nanoparticle applications generating signals as diverse as static and time-resolved luminescence, one- and two-photon absorption, Raman and Rayleigh scattering as well as surface plasmon resonance and others. In general, all endeavors cited are geared to achieve one or more of the following goals: lowering of detection limits (if possible, down to single-molecule level), parallel integration of multiple signals (multiplexing), signal amplification by several orders of magnitude and prevention of photobleaching effects with concomitant maintenance of antigen binding specificity and sensitivity. Inorganic nanoparticle labels based on noble metals, semiconductor quantum dots and nanoshells appear to be the most versatile systems for these bioanalytical applications of nanophotonics.
Collapse
|