1
|
Villiger M, Otsuka K, Karanasos A, Doradla P, Ren J, Lippok N, Shishkov M, Daemen J, Diletti R, van Geuns RJ, Zijlstra F, Dijkstra J, van Soest G, Regar E, Nadkarni SK, Bouma BE. Repeatability Assessment of Intravascular Polarimetry in Patients. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1618-1625. [PMID: 29969412 PMCID: PMC6088245 DOI: 10.1109/tmi.2018.2815979] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Intravascular polarimetry with polarization sensitive optical frequency domain imaging (PS-OFDI) measures polarization properties of the vessel wall and offers characterization of coronary atherosclerotic lesions beyond the cross-sectional image of arterial microstructure available to conventional OFDI. A previous study of intravascular polarimetry in cadaveric human coronary arteries found that tissue birefringence and depolarization provide valuable insight into key features of atherosclerotic plaques. In addition to various tissue components, catheter and sample motion can also influence the polarization of near infrared light as used by PS-OFDI. This paper aimed to evaluate the robustness and repeatability of imaging tissue birefringence and depolarization in a clinical setting. 30 patients scheduled for percutaneous coronary intervention at the Erasmus Medical Center underwent repeated PS-OFDI pullback imaging, using commercial imaging catheters in combination with a custom-built PS-OFDI console. We identified 274 matching cross sections among the repeat pullbacks to evaluate the reproducibility of the conventional backscatter intensity, the birefringence, and the depolarization signals at each spatial location across the vessel wall. Bland-Altman analysis revealed best agreement for the birefringence measurements, followed by backscatter intensity, and depolarization, when limiting the analysis to areas of meaningful birefringence. Pearson correlation analysis confirmed highest correlation for birefringence (0.86), preceding backscatter intensity (0.83), and depolarization (0.78). Our results demonstrate that intravascular polarimetry generates robust maps of tissue birefringence and depolarization in a clinical setting. This outcome motivates the use of intravascular polarimetry for future clinical studies that investigate polarization properties of arterial atherosclerosis.
Collapse
|
2
|
Nayak R, Schifitto G, Doyley MM. Visualizing Angle-Independent Principal Strains in the Longitudinal View of the Carotid Artery: Phantom and In Vivo Evaluation. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1379-1391. [PMID: 29685590 PMCID: PMC5960628 DOI: 10.1016/j.ultrasmedbio.2018.03.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2017] [Revised: 02/08/2018] [Accepted: 03/16/2018] [Indexed: 05/03/2023]
Abstract
Non-invasive vascular elastography can evaluate the stiffness of the carotid artery by visualizing the vascular strain distribution. Axial strain estimates of the longitudinal cross section of the carotid artery are sensitive to the angle between the artery and the transducer. Anatomical variations in branching and arching of the carotid artery can affect the assessment of arterial stiffness. In this study, we hypothesized that principal strain elastograms computed using compounded plane wave imaging can reliably visualize the strain distribution in the carotid artery, independent of the transducer angle. We corroborated this hypothesis by conducting phantom and in vivo studies using a commercial ultrasound scanner (Sonix RP, Ultrasonix Medical Corp., Richmond, BC, Canada). The phantom studies were conducted using a homogeneous cryogel vessel phantom. The goal of the phantom study was to assess the feasibility of visualizing the radial deformation in the longitudinal plane of the vessel phantom, independent of the transducer angle (±30°, ±20°, ±10° and 0°). The in vivo studies were conducted on 20 healthy human volunteers in the age group 50-60 y. All echo imaging was performed at a transmit frequency of 5 MHz and sampling frequency of 40 MHz. The elastograms obtained from the phantom study revealed that for straight vessels, which had their lumen parallel to the transducer, principal strains were similar to axial strains. At non-parallel configurations (angles ±30°, ±20° and ±10°), the magnitudes of the mean principal strains were within 2.5% of the parallel configuration (0° angle) estimates and, thus, were observed to be relatively unaffected by change in angle. However, in comparison, the magnitude of the axial strain decreased with increase in angle because of coordinate dependency. Further, the pilot in vivo study indicated that the principal and axial strain elastograms were similar for subjects with relatively straight arteries. However, for arteries with arched geometry, axial strains were significantly lower (p <0.01) than the corresponding principal vascular strains, which was consistent with the results obtained from the phantom study. In conclusion, the results of the phantom and in vivo studies revealed that principal strain elastograms computed using CPW imaging could reliably visualize angle-independent vascular strains in the longitudinal plane of the carotid artery.
Collapse
Affiliation(s)
- Rohit Nayak
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York, USA.
| | - Giovanni Schifitto
- Department of Neurology, School of Medicine and Dentistry, University of Rochester Medical Center, Rochester, New York, USA
| | - Marvin M Doyley
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York, USA; Department of Biomedical Engineering, University of Rochester, Rochester, New York, USA
| |
Collapse
|
3
|
Tedoriya T, Siniawski H, Tambeur L, Huebler M, Hetzer R. Coronary Artery Assessment by Epicardial Pulsed Doppler Ultrasound. Asian Cardiovasc Thorac Ann 2016. [DOI: 10.1177/021849230100900402] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
An intraoperative method was developed for direct investigation of the coronary arteries using an epicardial high-frequency two-dimensional Doppler ultrasound transducer. This fingertip 7.5-MHz transducer was used in 30 patients undergoing coronary artery bypass surgery to measure blood flow in the coronary arteries and bypass grafts. In all the patients, clear images of the coronary arteries and the bypass grafts were obtained in the beating heart, and coronary blood flow could be measured to evaluate the degree of stenosis. There were no significant differences between the measurements obtained with the Doppler transducer and a transit-time ultrasonic flowmeter of blood flow in the left internal thoracic artery graft to the left anterior descending coronary artery, indicating that the Doppler method produces accurate and reproducible measurements. This method can provide useful intraoperative information about the coronary artery system in emergency operations such as acute aortic dissection.
Collapse
Affiliation(s)
- Takeo Tedoriya
- Department of Cardiothoracic and Vascular Surgery German Heart Institute Berlin Berlin, Germany
| | - Henrik Siniawski
- Department of Cardiothoracic and Vascular Surgery German Heart Institute Berlin Berlin, Germany
| | - Luc Tambeur
- Department of Cardiothoracic and Vascular Surgery German Heart Institute Berlin Berlin, Germany
| | - Michael Huebler
- Department of Cardiothoracic and Vascular Surgery German Heart Institute Berlin Berlin, Germany
| | - Roland Hetzer
- Department of Cardiothoracic and Vascular Surgery German Heart Institute Berlin Berlin, Germany
| |
Collapse
|
4
|
Breburda CS, Koester H, Moosdorf R. Intraoperative assessment of coronary grafts by novel digital epivascular imaging. J Am Soc Echocardiogr 2003; 16:347-54. [PMID: 12712017 DOI: 10.1016/s0894-7317(03)00006-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
OBJECTIVE We sought to validate and evaluate 2 novel intraoperative ultrasound probes for epicoronary and epiaortic imaging. BACKGROUND The noninvasive intraoperative assessment of successful coronary artery bypass grafting remains a challenge. METHODS A total of 19 consecutive patients (4 female, 15 male; mean age 60.5 +/- 13.8 years SD, range 34-84) underwent coronary artery bypass grafting. The epivascular probes (GE Ultrasound) were validated in vitro and intraoperatively. Coronary arteries, grafts, and ascending aorta were imaged and quantified. RESULTS Mean adjusted flow measured by flowmeter was 3.25 L, SE 0.47 (range: 1-5.5 L) and was 3.15 L, SE 0.46 (range: 1-5.0 L) by ultrasound, with r = 0.97, P <.0001. Intraoperatively, 56 native coronary vessels were bypassed using 15 left internal mammary artery grafts, 25 vein grafts, and 16 venous jump grafts. A total of 15 left internal mammary artery grafts (100%), 12 left internal mammary artery anastomoses (80%), 20 vein grafts (15 left anterior descending coronary arteries, left circumflex artery grafts, 5 right coronary artery grafts) (80%), 4 jump grafts (25%), and 15 ascending aortas (78%) were successfully imaged by inexperienced surgeons. Doppler flow measurements were possible in 50 vessels (89%). Mean lumen diameter for graft arteries (veins) was 2 mm (2.87 mm), maximal velocity was 72 cm/s (46 cm/s), and mean velocity was 29 cm/s (21 cm/s) with a mean flow rate of 70 mL/m (55 mL/m). CONCLUSIONS We conclude that: (1) the novel intraoperative probes measure validated flow; (2) intraoperative hemodynamic assessment of graft patency is feasible without a learning curve; and (3) these findings should encourage the routine use of these intraoperative epivascular digital ultrasound probes.
Collapse
|
5
|
Fayad ZA, Fuster V, Fallon JT, Jayasundera T, Worthley SG, Helft G, Aguinaldo JG, Badimon JJ, Sharma SK. Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 2000; 102:506-10. [PMID: 10920061 DOI: 10.1161/01.cir.102.5.506] [Citation(s) in RCA: 336] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND High-resolution MRI has the potential to noninvasively image the human coronary artery wall and define the degree and nature of coronary artery disease. Coronary artery imaging by MR has been limited by artifacts related to blood flow and motion and by low spatial resolution. METHODS AND RESULTS We used a noninvasive black-blood (BB) MRI (BB-MR) method, free of motion and blood-flow artifacts, for high-resolution (down to 0.46 mm in-plane resolution and 3-mm slice thickness) imaging of the coronary artery lumen and wall. In vivo BB-MR of both normal and atherosclerotic human coronary arteries was performed in 13 subjects: 8 normal subjects and 5 patients with coronary artery disease. The average coronary wall thickness for each cross-sectional image was 0.75+/-0.17 mm (range, 0.55 to 1.0 mm) in the normal subjects. MR images of coronary arteries in patients with >/=40% stenosis as assessed by x-ray angiography showed localized wall thickness of 4.38+/-0.71 mm (range, 3.30 to 5.73 mm). The difference in maximum wall thickness between the normal subjects and patients was statistically significant (P<0.0001). CONCLUSIONS In vivo high-spatial-resolution BB-MR provides a unique new method to noninvasively image and assess the morphological features of human coronary arteries. This may allow the identification of atherosclerotic disease before it is symptomatic. Further studies are necessary to identify the different plaque components and to assess lesions in asymptomatic patients and their outcomes.
Collapse
Affiliation(s)
- Z A Fayad
- Zena and Michael A. Wiener Cardiovascular Institute, Department of Radiology, Mount Sinai School of Medicine, New York, NY 10029, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Hort W, Schwartzkopff B. Anatomie und Pathologie der Koronararterien. PATHOLOGIE DES ENDOKARD, DER KRANZARTERIEN UND DES MYOKARD 2000. [DOI: 10.1007/978-3-642-56944-9_3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
7
|
Verin V, Popowski Y. Intraarterial beta irradiation to reduce restenosis after PTCA. Experimental and clinical experience. Herz 1998; 23:347-55. [PMID: 9816520 DOI: 10.1007/bf03043599] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The present data demonstrate clinical feasibility of intracoronary beta brachytherapy and fail to reveal any complications that could be attributed to it. Definitive conclusions regarding safety will have to await longer term evaluation. Proof of efficacy will require strict dose finding evaluation of higher doses than those used in the present pilot study followed by a controlled, randomized trial using both clinical and angiographic end-points.
Collapse
Affiliation(s)
- V Verin
- Cardiology Center, University Hospital, Geneva, Switzerland.
| | | |
Collapse
|
8
|
Ishikura F, Matsuwaka R, Sakakibara T, Sakata Y, Hirayama A, Kodama K. Clinical application of power Doppler imaging to visualize coronary arteries in human beings. J Am Soc Echocardiogr 1998; 11:219-27. [PMID: 9560745 DOI: 10.1016/s0894-7317(98)70083-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Supplementation of angiographic information during bypass procedures is an attractive goal for the echocardiographic researcher. Compared with color flow mapping, power Doppler imaging is superior in terms of identifying small vessels and noise suppression because of the use of Doppler signal strength for imaging. Although power Doppler imaging does not provide information about flow velocity or its direction, it does show detailed vessel flow in a static organ. Our study was designed to obtain angiographic images of the coronary artery by the use of power Doppler imaging in 31 patients during open heart surgery. During cold cardioplegic infusion, the epicardial coronary artery and the coronary artery within myocardium, such as the septal perforator, could be well visualized by power Doppler imaging. There was good correlation between the diameters of coronary arteries measured from power Doppler imaging and those from quantitative coronary angiography (r = 0.964, p < 0.0001). We obtained clear and accurate images of the coronary artery by using power Doppler imaging during cardiac standstill. These images might provide meaningful supplemental information to the operator, such as confirming the target coronary artery during the cardioplegia and choosing the appropriate arterial portion for a bypass operation.
Collapse
Affiliation(s)
- F Ishikura
- Cardiovascular Division, Cardiovascular Surgery, Osaka Police Hospital
| | | | | | | | | | | |
Collapse
|
9
|
Oniki T, Iwakami M. Is arterial remodeling truly a compensatory biological reaction? A mechanical deformation hypothesis. Atherosclerosis 1997; 132:115-8. [PMID: 9247366 DOI: 10.1016/s0021-9150(97)00052-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
It has been recognized that arterial enlargement occurs in relation to the formation of atherosclerotic plaque. Previous studies on arterial remodeling have disregarded the role of mechanical deformation and have suggested that compensatory mechanisms occur to maintain arterial flow. We postulated that primary atherosclerotic enlargement and mechanical deformation are the predominant causes of the arterial remodeling. This hypothesis better explains the morphological changes without suggesting additional biological reactions.
Collapse
Affiliation(s)
- T Oniki
- Department of Internal Medicine, Kawaguchi Kogyo General Hospital, Kawaguchi-shi, Saitama, Japan
| | | |
Collapse
|
10
|
Abstract
It is increasingly recognized that sex steroids have, among many other effects, the ability to cause vasodilation. The vasodilatory effects of estradiol have been the best documented and described. At low concentrations, estradiol has the ability to improve impaired endothelium dependent (nitric oxide mediated) relaxation in estrogen deficient subjects. At high concentrations, estradiol causes vasodilation principally by endothelium independent mechanisms, in a gender independent fashion, which appear to involve a number of pathways such as ATP-dependent K+ channels. Testosterone also has ability, at higher doses, to cause vasodilation of the coronary circulation, in a gender independent fashion. The mechanisms of sex steroid-induced vasodilation are reviewed in this article.
Collapse
Affiliation(s)
- S J Hutchison
- Division of Cardiology, University of California, San Francisco, USA
| | | | | | | |
Collapse
|
11
|
Podesser B, Wollenek G, Seitelberger R, Siegel H, Wolner E, Firbas W, Tschabitscher M. Epicardial branches of the coronary arteries and their distribution in the rabbit heart: the rabbit heart as a model of regional ischemia. Anat Rec (Hoboken) 1997; 247:521-7. [PMID: 9096792 DOI: 10.1002/(sici)1097-0185(199704)247:4<521::aid-ar11>3.0.co;2-r] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND The rabbit heart has been frequently used to study regional ischemia, but there is hardly any detailed information on the epicardial branching of the coronary arteries. Therefore, we wanted to determine whether there is a constant branching pattern and how comparable this pattern is with the human heart. METHODS We investigated epicardial branching of the coronary arteries in 30 adult rabbit hearts. For vessel visualisation, we used injections of Technovit, followed by corrosion. RESULTS We found that there is not one constant pattern but rather a bifurcation or a trifurcation of the arteria coronaria sinistra (15 of 15 hearts). The left coronary artery is always the dominant artery; a vessel comparable to the human ramus interventricularis anterior is rarely found in the bifurcation type. The ramus circumflexus is a constant but minor branch of the posterior or posterolateral division and does not originate directly from the main stem of the left coronary artery, as it does in humans. As a consequence, ligation of the left ramus interventricularis anterior leads to severe ischemic injury only where trifurcation exists (50% of our population). A ligation of the ramus circumflexus proximal to its origin produces a large posterolateral infarction in the bifurcation type (50% of our population). CONCLUSIONS Because a defined ischemic area is difficult to reproduce under these anatomical conditions, the rabbit heart may be a model only for regional ischemia if the investigator is knowledgeable about the distributions of the coronary arteries.
Collapse
Affiliation(s)
- B Podesser
- Department of Cardiothoracic Surgery General Hospital Vienna, Austria
| | | | | | | | | | | | | |
Collapse
|
12
|
Verin V, Urban P, Popowski Y, Schwager M, Nouet P, Dorsaz PA, Chatelain P, Kurtz JM, Rutishauser W. Feasibility of intracoronary beta-irradiation to reduce restenosis after balloon angioplasty. A clinical pilot study. Circulation 1997; 95:1138-44. [PMID: 9054842 DOI: 10.1161/01.cir.95.5.1138] [Citation(s) in RCA: 103] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND With the aim of decreasing the incidence of restenosis after coronary balloon angioplasty, we developed a technique of intracoronary beta-irradiation using an endoluminally centered pure metallic 90Y source. The purpose of the present study was to evaluate the clinical feasibility and safety profile of this approach with a dose of 18 Gy delivered to the inner arterial surface. METHODS AND RESULTS Between June 21 and November 15, 1995, fifteen patients (6 women and 9 men; mean age, 71 +/- 5 years) underwent intracoronary beta-irradiation immediately after a conventional percutaneous transluminal coronary angioplasty (PTCA) procedure. The PTCA/irradiation procedure was technically feasible in all attempted cases, and the delivery of the 18 Gy dose was accomplished without complications. In 4 patients, the intervention was completed through intra-arterial stent implantation because of dissection induced by the initial PTCA. During the follow-up period of 178 +/- 17 days (range, 150 to 225 days), no complication occurred that could be attributed to radiation therapy. No aneurysm or angiographically detectable thrombus was observed in any of the irradiated arterial segments. The clinical event rate (4 of 15 patients underwent further target lesion revascularization) and the angiographic follow-up (6 of 15 patients had a > 50%-diameter stenosis at the previously treated site) did not suggest a marked impact on the expected restenosis rate. CONCLUSIONS This early experience demonstrates that our approach is feasible, and no side effects attributable to radiation were noted during a 6-month period of follow-up. Whether higher doses of beta-irradiation will favorably affect post-PTCA restenosis in patients must await further evaluation.
Collapse
Affiliation(s)
- V Verin
- Cardiology Center, University Hospital, Geneva, Switzerland
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Abstract
This article provides the reader with some idea of the principles and techniques of three-dimensional reconstruction using intravascular imaging data. The article also describes new intravascular ultrasound imaging devices that have the ability to interrogate the arterial wall ahead of the imaging catheter.
Collapse
Affiliation(s)
- D D McPherson
- Division of Cardiology, Northwestern University Medical School, Chicago, Illinois, USA
| | | |
Collapse
|
14
|
Kimura BJ, Russo RJ, Bhargava V, McDaniel MB, Peterson KL, DeMaria AN. Atheroma morphology and distribution in proximal left anterior descending coronary artery: in vivo observations. J Am Coll Cardiol 1996; 27:825-31. [PMID: 8613610 DOI: 10.1016/0735-1097(95)00551-x] [Citation(s) in RCA: 99] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
OBJECTIVES This study sought to examine, in vivo, the shape and position of atheroma in the proximal left anterior descending coronary artery. BACKGROUND The prevalence, shape and location of atheromas involving the proximal left anterior descending artery have implications regarding the role of disturbed shear forces in the genesis of atherosclerosis. However, no data are available regarding in vivo findings or advanced disease. METHODS Forty-two consecutive high quality intravascular ultrasound images were examined from patients with atherosclerotic disease in the proximal left anterior descending artery just distal to the left main bifurcation. Lesion percent area stenosis and maximal, minimal and flow divider intimal-medial thickness were measured at the region immediately after the circumflex takeoff. The angle formed by the midpoint of the flow divider, the human center of gravity and the maximal plaque thickness were determined. RESULTS Eccentricity of vessel wall atheroma was observed such that the maximal wall thickness (1.42 +/- 0.50 mm [mean +/- SD]) differed significantly from minimal wall thickness (0.17 +/- 0.098 mm). Further, the region of vessel wall manifesting maximal thickness was greater than the flow divider thickness (0.26 +/- 0.16 mm). Maximal plaque thickness spared the region of the flow divider in 100% of cases and was positioned at a mean angle of 193 +/- 49 degrees from the center of the flow divider. Eccentric morphology was maintained across the 24% to 80% range of area stenosis. CONCLUSIONS Atheromas in the very proximal left anterior descending artery are located opposite the circumflex takeoff, spare the flow divider and maintain eccentricity across a wide range of vessel stenoses. These in vivo morphologic data support the potential role of fluid dynamic mechanical factors in atherogenesis and have implications regarding the success of catheter-based interventional procedures at the site.
Collapse
Affiliation(s)
- B J Kimura
- Division of Cardiovascular Medicine, University of California-San Diego Medical Center, California 92103, USA
| | | | | | | | | | | |
Collapse
|
15
|
McPherson DD, Sirna S, Collins SM, Ross AF, Moyers JR, Kane BJ, Hiratzka LF, Marcus ML, Kerber RE. Can atherosclerotic coronary arteries vasodilate? An intraoperative high-frequency epicardial echocardiographic study. Am J Cardiol 1995; 76:21-5. [PMID: 7793397 DOI: 10.1016/s0002-9149(99)80794-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Our purpose was to evaluate the vasodilating responses of atherosclerotic coronary arteries using intraoperative high-frequency (12 MHz) epicardial echocardiography. We obtained continuous high-frequency epicardial echocardiographic recordings during surgery, and determined cross-sectional lumen area from 17 coronary arterial segments (12 patients). Nitroglycerin (100 to 400 micrograms/min) was administered intravenously to reduce mean (+/- SEM) arterial pressure 14 +/- 1.8 mm Hg. The cross-sectional arterial images were classified using 3 different parameters: arterial lumen area, percentage of the arterial wall circumference that was atherosclerotic (wall thickness > 0.7 mm), and presence of an eccentrically shaped arterial lumen (maximal/minimal luminal diameter > 1.5). Nine arterial segments had small (< 5.0 mm2) arterial lumens (1.7 +/- 0.40 mm2 [+/- SEM; range 0.6 to 3.9]). With nitroglycerin, the luminal area increased 0.8 +/- 0.28 mm2 (range 0 to 2.5), and 39 +/- 12.1% (range 0 to 117). The remaining 8 segments had larger (> 5.0 mm2) lumens (8.7 +/- 0.91 mm2 [range 5.0 to 11.9]). With nitroglycerin the luminal area increased 4.3 +/- 1.11 mm2 (range 1.4 to 11.4), and 51 +/- 10.2% (range 16 to 96). Seven arterial segments had eccentric lumens; mean maximal/minimal ratio was 1.8 +/- 0.08 (range 1.6 to 2.0). The area increased 39 +/- 7.3% (range 16 to 71) with nitroglycerin. In the 10 concentrically shaped lumens (maximal/minimal lumen diameters 1.3 +/- 0.04 [range 1.1 to 1.5]), nitroglycerin increased luminal area by 48 +/- 12.6% (range 0 to 117) (p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- D D McPherson
- Department of Medicine, University of Iowa, Iowa City, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Herrera CJ, Frazin LJ, Dau PC, DeFrino P, Stone NJ, Mehlman DJ, Vonesh MJ, Talano JV, McPherson DD. Atherosclerotic plaque evolution in the descending thoracic aorta in familial hypercholesterolemic patients. A transesophageal echo study. ARTERIOSCLEROSIS AND THROMBOSIS : A JOURNAL OF VASCULAR BIOLOGY 1994; 14:1723-9. [PMID: 7947595 DOI: 10.1161/01.atv.14.11.1723] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
We explored the concept that transesophageal echocardiography can be used as a tool to detect, characterize, and study plaque morphology in the descending thoracic aorta. The pattern of atherosclerotic plaques in the descending thoracic aorta in familial hypercholesterolemic (FH) patients was evaluated. Additionally, evolution of plaque characteristics as a result of therapy was analyzed. In a randomized prospective protocol, eight FH patients (five men and three women, aged 23 to 65 years [mean +/- SD, 42 +/- 14 years]) receiving standard therapy (n = 3; baseline low-density lipoprotein [LDL] cholesterol, 222 +/- 71 mg/dL, mean +/- SD) or LDL apheresis (n = 5; baseline LDL cholesterol, 262 +/- 51 mg/dL) were studied. Baseline and follow-up (mean, 12 months) transesophageal echocardiographic studies were performed. Measurements obtained were atherosclerotic plaque area (PA), aortic wall area (WA), total arterial area (TAA), and plaque-to-wall area ratio (PWR). LDL cholesterol decreased in both groups. The greatest severity of plaque was detected at 30 to 35 cm from the incisors (approximately 15 to 20 cm from the aortic arch). The smallest plaques were present at the arch and more distal descending aorta. In the control group, TAA, PA, and PWR did not change significantly (P = NS versus baseline). In the LDL-apheresis group, TAA increased (P < .05 versus baseline), PA decreased in three of five patients (P = NS versus baseline), and PWR fell (P < .05 versus baseline).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- C J Herrera
- Department of Medicine, Evanston Hospital, Ill
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Di Mario C, Strikwerda S, Gil R, de Feyter PJ, de Jaegere P, Serruys PW. Response of conductance and resistance coronary vessels to scalar concentrations of acetylcholine: assessment with quantitative angiography and intracoronary Doppler echography in 29 patients with coronary artery disease. Am Heart J 1994; 127:514-31. [PMID: 8122597 DOI: 10.1016/0002-8703(94)90658-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Abnormal vasoreactivity of the large conductance arteries has been observed in the presence of impaired endothelial function. More recently, experimental and clinical reports have shown that in early coronary atherosclerosis the impairment of the endothelium-mediated vasodilatation also involves the resistance arteries. The aim of this study is the correlation of endothelium-dependent vasodilatation of conductance and resistance vessels in coronary arteries without significant stenoses. In 29 patients (aged 57 +/- 9 years, 24 men and 5 women) undergoing coronary angioplasty, a Doppler guide wire and a perfusion catheter were introduced into the proximal segment of an artery with less than 30% diameter stenosis. Selective infusions of papaverine (bolus of 7 mg), acetylcholine (continuous infusion of 0.036, 0.36, and 3.6 micrograms/ml at a flow rate of 2 ml/min), and isosorbide dinitrate (bolus of 3 mg) were sequentially performed. Heart rate, aortic blood pressure, and blood flow velocity were continuously measured. Mean cross-sectional areas of a proximal and a distal arterial segment were measured in baseline conditions, at the end of each infusion of acetylcholine, and at the peak effect of isosorbide dinitrate with quantitative angiography (CAAS System; Pie Medical Data, Maastricht, The Netherlands). Coronary blood flow was calculated from the time-averaged flow velocity and the cross-sectional area at the site of the Doppler sample volume. Coronary flow resistance was calculated as mean aortic pressure divided by coronary flow. All of the concentrations of acetylcholine induced a significant vasoconstriction of the studied artery. At the maximal concentration of acetylcholine all but three patients (90%) showed a reduction of cross-sectional area (-24% +/- 20% and -22% +/- 20% for the proximal and distal segments, respectively, p < 0.00001). Flow velocity showed a significant increase only with the two highest concentrations of acetylcholine. The maximal concentration induced a 105% +/- 138% increase from the baseline flow velocity (p < 0.001). The coronary flow changes after acetylcholine showed a large interpatient variability, with a mean increase from baseline after the highest dose of +43% +/- 85% (range, -60% +/- 239%), with the presence of a flow reduction in 10 patients (35%). No clinical or angiographic variables showed a significant correlation with the cross-sectional area, flow velocity, and flow changes after infusion of acetylcholine.(ABSTRACT TRUNCATED AT 400 WORDS)
Collapse
Affiliation(s)
- C Di Mario
- Cardiac Catheterization Laboratory, Erasmus University, Rotterdam, The Netherlands
| | | | | | | | | | | |
Collapse
|
18
|
Evans JL, Ng KH, Vonesh MJ, Kramer BL, Meyers SN, Mills TA, Kane BJ, Aldrich WN, Jang YT, Yock PG. Arterial imaging with a new forward-viewing intravascular ultrasound catheter, I. Initial studies. Circulation 1994; 89:712-7. [PMID: 8313559 DOI: 10.1161/01.cir.89.2.712] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
BACKGROUND Intravascular ultrasound (IVUS) of arteries is limited by the inability of current instruments to visualize beyond the catheter tip. We have developed a prototype 4-mm-diameter forward-viewing IVUS catheter (Cardiovascular Imaging Systems, Sunnyvale, Calif) that has the ability to provide B-mode cross-sectional ultrasound data for a distance of up to 2 cm distal to the catheter tip. METHODS AND RESULTS To study the utility of this device, a 20-MHz forward-viewing IVUS catheter was used to examine 13 arterial segments (5 human femoral arteries, 1 human carotid artery, 7 canine arteries) in vitro and 1 phantom. After imaging, all data were compared with histology (Histo). In all cases, the IVUS catheter provided forward-viewing images corresponding to the arterial geometry and demonstrated vascular landmarks and atherosclerotic lesions. There was a good correlation between Histo-determined luminal diameters (LD) and IVUS-determined diameters for a distance of 14 mm ahead of the catheter tip: IVUS LD = 1.0 Histo LD + 1.3 (r = .87). CONCLUSIONS These preliminary data suggest that a forward-viewing IVUS catheter is feasible, accurate, and useful for evaluation of arterial geometry distal to the catheter tip.
Collapse
Affiliation(s)
- J L Evans
- Feinberg Cardiovascular Research Institute, Northwestern University Medical School, Chicago, Ill
| | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Porter TR, Sears T, Xie F, Michels A, Mata J, Welsh D, Shurmur S. Intravascular ultrasound study of angiographically mildly diseased coronary arteries. J Am Coll Cardiol 1993; 22:1858-65. [PMID: 8245340 DOI: 10.1016/0735-1097(93)90770-2] [Citation(s) in RCA: 78] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVES We hypothesized that intravascular ultrasound may identify significant coronary artery narrowing in the mildly diseased coronary artery of patients with insignificant or one- or two-vessel coronary artery disease. BACKGROUND Necropsy studies have revealed that coronary angiography may underestimate stenosis severity in vessels that appear mildly diseased. Intravascular ultrasound has been shown to detect atherosclerotic changes in angiographically normal coronary arteries and to correlate better with histologic findings. METHODS In 20 patients, we performed intravascular ultrasound imaging (3.5F catheter, 30-MHz transducer) in 37 coronary arteries that were considered mildly diseased (<50% diameter narrowing) by qualitative angiography. The angiographic diagnosis was no significant coronary artery disease in eight patients, one-vessel disease in seven and two-vessel disease in five. Each vessel, except for the left main coronary artery, was divided into proximal, mid and distal segments. Percent area narrowing and minimal lumen diameter were subsequently quantified by both ultrasound and quantitative angiography. RESULTS Mean maximal arterial area narrowing by ultrasound in the 67 segments studied was 36 +/- 20% (range 0% to 80.2%) and 19 +/- 23% (range 0% to 82%) by quantitative angiography of these same segments (p < 0.001, paired t test). Mean minimal lumen diameter of the segment was 3.3 +/- 0.9 mm by ultrasound and 2.7 +/- 0.8 mm by quantitative angiography. In 10 patients there were 19 angiographically mildly diseased segments where the percent arterial area narrowing by ultrasound was > or = 50%. Intravascular ultrasound revealed that the more proximal (reference) segment had > 25% intimal thickening in 12 of the 19 underestimated segments. In six stenosed segments (32%), total vessel area increased compared with that of the adjacent proximal vessel segment because of compensatory dilation. CONCLUSIONS Intravascular ultrasound identifies potentially significant coronary artery disease in vessels that appear to be only mildly diseased by angiography.
Collapse
Affiliation(s)
- T R Porter
- Section of Cardiology, University of Nebraska Medical Center, Omaha 68198-2265
| | | | | | | | | | | | | |
Collapse
|
20
|
Faletra F, Cipriani M, Corno R, Calì G, Mantero A, Cantoni S, Formentini A, Danzi GB, Pezzano A. Transthoracic high-frequency echocardiographic detection of atherosclerotic lesions in the descending portion of the left coronary artery. J Am Soc Echocardiogr 1993; 6:290-8. [PMID: 8333978 DOI: 10.1016/s0894-7317(14)80066-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
To assess the ability of transthoracic high-frequency two-dimensional echocardiography to detect atherosclerotic lesions in the descending portion of the left coronary artery, 30 consecutive patients with suspected coronary artery disease underwent two-dimensional echocardiographic examination 24 to 96 hours before coronary angiography. The descending portion of the left coronary artery was arbitrarily divided into a mid segment (the portion of the coronary vessel embedded in the anterior interventricular sulcus) and an apical segment (the portion turning around the cardiac apex into the posterior interventricular sulcus). The mid segment was imaged in 24 and the apical segment in 25 of the 30 patients for a total of 49 out of 60 segments (82%). Comparison of the echocardiographically visualized segments with the corresponding angiographic segments indicated that a correct echocardiographic diagnosis of significant stenosis was made in 11 out of 12 segments. There were no false positive results. Thus the sensitivity and specificity of high-frequency transthoracic echocardiography in the detection of significant stenosis in the imaged segments were 92% and 100%, respectively. Compared with angiography, additional information concerning the status of the arterial wall, the presence of calcific plaques, and the cross-sectional extent of the obstructive lesions was obtained by echocardiography in eight patients.
Collapse
Affiliation(s)
- F Faletra
- Central Cardiology Service, A. De Gasperis Cardiology Department, Niguarda-Cà Granda Hospital, Milano, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Vos J, de Feyter PJ, Simoons ML, Tijssen JG, Deckers JW. Retardation and arrest of progression or regression of coronary artery disease: a review. Prog Cardiovasc Dis 1993; 35:435-54. [PMID: 8497659 DOI: 10.1016/0033-0620(93)90028-c] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Affiliation(s)
- J Vos
- Thoraxcenter, University Hospital Dijkzigt, Erasmus University Rotterdam, Rotterdam, The Netherlands
| | | | | | | | | |
Collapse
|
22
|
McPherson DD, Johnson MR, Collins SM, Kieso RA, Marcus ML, Kerber RE. Validation by high-frequency epicardial echocardiography of a new method of analyzing coronary angiography quantitatively in coronary artery disease. Am J Cardiol 1993; 71:28-32. [PMID: 8420232 DOI: 10.1016/0002-9149(93)90705-h] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
In coronary atherosclerosis, the arterial lumen size and shape can be markedly irregular, eccentric and variable. Traditional angiographic interpretation, emphasizing percent diameter stenosis, has been criticized as an inadequate descriptor of such diseased arteries. Computerized quantitative angiographic technologies, yielding a true lumen area measurement, may be superior. High-frequency epicardial echocardiography (HFEE) is a technique that allows on-line evaluation of coronary arterial wall and lumen at the time of cardiac surgery. It has been extensively validated and yields accurate measurements of normal and diseased coronary lumen areas. This study compares quantitative coronary angiography (QCA) estimates of lumen area to those obtained by HFEE to determine if the computerized angiographic method more accurately predicts residual luminal area than traditional angiographic percent diameter stenosis measurements. Although actual luminal morphology was quite variable, there was a good correlation between lumen areas determined by HFEE versus QCA: r = 0.85, n = 67, HFEE = 0.8 QCA - 0.1 (HFEE 4.0 +/- 0.30 mm2, mean +/- SEM range 0.3 to 14.0; QCA 5.1 +/- 0.40 mm2, range 0.7 to 11.8). Percent diameter stenosis determined from the angiograms did not correlate well with HFEE or QCA measurements of residual luminal area. Separation of "normal" arterial segments (defined as < 25% diameter stenosis) from "abnormal" segments (> 50% diameter stenosis) by angiography did not agree with lumen areas as defined by either HFEE or QCA. Better separation occurred when QCA-determined luminal areas were used to separate normal from abnormal arterial segments.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- D D McPherson
- Department of Medicine, Northwestern Memorial Hospital, Northwestern University, Chicago, Illinois 60611
| | | | | | | | | | | |
Collapse
|