1
|
Ferré A, Dres M, Roche N, Antignac M, Becquemin MH, Trosini V, Vecellio L, Chantrel G, Dubus JC. [Inhalation devices: characteristics, modeling, regulation and use in routine practice. GAT Aerosolstorming, Paris 2011]. Rev Mal Respir 2012; 29:191-204. [PMID: 22405113 DOI: 10.1016/j.rmr.2011.12.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2011] [Accepted: 12/27/2011] [Indexed: 10/14/2022]
Abstract
Aerosoltherapy is a first-line treatment for chronic obstructive respiratory diseases such as asthma and COPD. Treatment modalities and devices are varied and the choice of the device must be adapted to and optimized for every patient. Spacers can be used for some categories of patients for whom the use of other devices turns out to be complicated. The improvement of these treatments requires the optimization of the lung deposition of inhaled particles; lung modeling plays an essential role in the understanding of the mechanisms of flow in the airways. Regulations must frame prescription of inhaled treatments to optimize its quality and, thus, the care for these chronic diseases. Many generally-accepted ideas concerning these treatments turn out to be false. Inhaled treatments are constantly evolving, both pharmacologically and technologically.
Collapse
Affiliation(s)
- A Ferré
- Service de pneumologie et réanimation, université Paris Descartes, Hôtel-Dieu, Paris, France
| | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Bahadori K, Quon BS, Doyle-Waters MM, Marra C, Fitzgerald JM. A systematic review of economic evaluations of therapy in asthma. J Asthma Allergy 2010; 3:33-42. [PMID: 21437038 PMCID: PMC3047905 DOI: 10.2147/jaa.s11038] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2010] [Indexed: 11/23/2022] Open
Abstract
Background: Asthma’s cost-effectiveness is a major consideration in the evaluation of its treatment options. Our objective was to perform a systematic review of the cost-effectiveness of asthma medications. Methods: We performed a systematic search of MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, OHE-HEED, Database of Abstracts of Reviews of Effects, Cochrane Central Register of Controlled Trials, Health Technology Assessments Database, NHS Economic Evaluation Database, and Web of Science and reviewed references from key articles between 1990 and Jan 2008. Results: A total of 49 RCTs met the inclusion criteria. Maintenance therapy with inhaled corticosteroids was found to be very cost-effective and in uncontrolled asthmatics patients currently being treated with ICS, the combination of an ICS/LABA represents a safe, cost-effective treatment. The simplified strategy using budesonide and formoterol for maintenance and reliever therapy was also found to be as cost-effective as salmeterol/fluticasone plus salbutamol. Omalizumab was found to be cost-effective. An important caveat with regard to the published literature is the relatively high proportion of economic evaluations which are funded by the manufacturers of specific drug treatments. Conclusion: Future studies should be completed independent of industry support and ensure that the comparator arms within studies should include dosages of drugs that are equivalent.
Collapse
|
3
|
Affiliation(s)
- Michael J Welch
- From the Allergy and Asthma Medical Group and Research Center, San Diego, California 92123, USA.
| |
Collapse
|
4
|
Adams N, Lasserson TJ, Cates CJ, Jones PW. Fluticasone versus beclomethasone or budesonide for chronic asthma in adults and children. Cochrane Database Syst Rev 2007; 2007:CD002310. [PMID: 17943772 PMCID: PMC8447218 DOI: 10.1002/14651858.cd002310.pub4] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
BACKGROUND Beclomethasone dipropionate (BDP) and budesonide (BUD) are commonly prescribed inhaled corticosteroids for the treatment of asthma. Fluticasone propionate (FP) is newer agent with greater potency in in-vitro assays. OBJECTIVES To compare the efficacy and safety of Fluticasone to Beclomethasone or Budesonide in the treatment of chronic asthma. SEARCH STRATEGY We searched the Cochrane Airways Group trial register (January 2007) and reference lists of articles. We contacted trialists and pharmaceutical companies for additional studies and searched abstracts of major respiratory society meetings (1997 to 2006). SELECTION CRITERIA Randomised trials in children and adults comparing Fluticasone to either Beclomethasone or Budesonide in the treatment of chronic asthma. DATA COLLECTION AND ANALYSIS Two reviewers independently assessed articles for inclusion and methodological quality. One reviewer extracted data. Quantitative analyses were undertaken using RevMan analyses 1.0.1. MAIN RESULTS Seventy-one studies (14,602 participants) representing 74 randomised comparisons met the inclusion criteria. Methodological quality was fair. Dose ratio 1:2: FP produced a significantly greater end of treatment FEV1 (0.04 litres (95% CI 0 to 0.07 litres), end of treatment and change in morning PEF, but not change in FEV1 or evening PEF. This applied to all drug doses, age groups, and delivery devices. No difference between FP and BDP/BUD were seen for trial withdrawals. FP led to fewer symptoms and less rescue medication use. When given at half the dose of BDP/BUD, FP led to a greater likelihood of pharyngitis. There was no difference in the likelihood of oral candidiasis. Plasma cortisol and 24 hour urinary cortisol was measured frequently but data presentation was limited. Dose ratio 1:1: FP produced a statistically significant difference in morning PEF, evening PEF, and FEV1 over BDP or BUD. The effects on exacerbations were mixed. There were no significant differences incidence of hoarseness, pharyngitis, candidiasis, or cough. AUTHORS' CONCLUSIONS Fluticasone given at half the daily dose of beclomethasone or budesonide leads to small improvements in measures of airway calibre, but it appears to have a higher risk of causing sore throat and when given at the same daily dose leads to increased hoarseness. There are concerns about adrenal suppression with Fluticasone given to children at doses greater than 400 mcg/day, but the randomised trials included in this review did not provide sufficient data to address this issue.
Collapse
Affiliation(s)
- N Adams
- Worthing & Southlands NHS Trust, Respiratory Medicine, Worthing, UK.
| | | | | | | |
Collapse
|
5
|
Gawchik SM. Successful treatment of previously uncontrolled adult asthma with budesonide inhalation suspension: five-year case histories. Ann Pharmacother 2007; 41:1728-33. [PMID: 17698895 DOI: 10.1345/aph.1k133] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
OBJECTIVE To determine whether nebulized budesonide inhalation suspension (BIS) is effective in treating adults with asthma that has been uncontrolled by inhaled therapies. CASE SUMMARIES Three adults with severe persistent asthma were switched to BIS after poor outcomes with other controller medications, including inhaled corticosteroids (ICSs). BIS dosages were initiated with 1 mg twice daily. Based on physician discretion as symptoms improved, dosages were decreased to 0.5 mg twice daily (2 pts.) or once daily (1 pt.). Patients were instructed to self-manage their asthma, increasing their dosages during periods of asthma worsening. Peak expiratory flow (PEF) was assessed before and after the initiation of BIS. The number of healthcare visits and oral corticosteroid courses recorded in patient medical records during the 3 years before and 5 years after initiation of BIS therapy were compared. In all 3 cases, BIS improved asthma control. BIS consistently increased PEF and reduced the number of urgent care visits and oral corticosteroid courses. All patients reported satisfaction with BIS therapy. DISCUSSION Despite proven effectiveness of ICSs for persistent asthma, some patients fail to respond optimally to treatment administered via an inhaler. These 3 case reports suggest that BIS is effective in treating adults with severe persistent asthma who fail to respond optimally to treatment with other ICS preparations. Failure to use inhalers properly, previous poor adherence in 1 case, or patient preference for the nebulizer might explain why nebulized BIS was more effective than other inhaler therapies. CONCLUSIONS Switching adults with uncontrolled asthma to BIS therapy may be a valuable treatment option for those who are unable to achieve optimal asthma control, despite asthma education and training on inhaler technique.
Collapse
Affiliation(s)
- Sandra M Gawchik
- Asthma and Allergy Associates, Crozer-Chester Medical Center, 1 President's Dr., Upland, PA 19013, USA.
| |
Collapse
|
6
|
Cates CJ, Bestall J, Adams N. Holding chambers versus nebulisers for inhaled steroids in chronic asthma. Cochrane Database Syst Rev 2006; 2006:CD001491. [PMID: 16437434 PMCID: PMC8407361 DOI: 10.1002/14651858.cd001491.pub2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Inhaled corticosteroids are available in the form of a suspension for nebulisation, although the role of this mode of therapy in the treatment of chronic asthma is still unclear. OBJECTIVES To assess the efficacy and safety of inhaled corticosteroids delivered via nebuliser versus holding chamber for the treatment of chronic asthma. SEARCH STRATEGY We searched the Cochrane Airways Group Trial Register (1999) and reference lists of articles. We contacted the authors of studies and pharmaceutical companies for additional studies and hand-searched the British Journal of Clinical Research, European Journal of Clinical Research and major respiratory society meeting abstracts (1997-1999). Date of last search August 2005. SELECTION CRITERIA Randomised controlled trials comparing nebuliser to holding chamber in the delivery of inhaled corticosteroids for the treatment of chronic asthma. All age groups of patients were considered. Two reviewers assessed articles for inclusion; two reviewers independently assessed included studies for methodological quality. DATA COLLECTION AND ANALYSIS One reviewer extracted data; authors were contacted to clarify missing information. Quantitative analyses were undertaken using Review Manager 4.1 with MetaView 3.1. MAIN RESULTS Two studies were selected for inclusion (63 subjects), both concerned adults. An additional small study including 14 children was identified for the 2005 update. Methodological quality was variable. Due to design differences it was not appropriate to pool the studies. The single high quality study compared budesonide 2000-8000 mcg delivered via Pari Inhalier Boy jet nebuliser with inspiration-only inhalation to budesonide 1600 mcg via large volume spacer. The nebuliser delivery led to higher morning peak expiratory flow values (25 L/min p<0.01), higher evening values (30L/min, p<0.01), lower rescue beta2 agonist use and symptom scores compared to the holding chamber delivery. AUTHORS' CONCLUSIONS Budesonide in high dose delivered by the particular nebuliser used in the only double-blinded study that could be included in this review was more effective than budesonide 1600 mcg via a large volume spacer. However, it is not clear whether this was an effect of nominal dose delivered or delivery system. Cost, compliance and patient preference are important determinants of clinical effectiveness that still require further assessment. Future studies are needed to evaluate the relative effectiveness of inhaled corticosteroids delivered by different combinations of nebuliser/compressor compared to holding chamber. Moreover, further studies assessing these delivery methods are needed in infants and pre-school children, as these are groups that are likely to be considered for treatment with nebulised corticosteroids.
Collapse
Affiliation(s)
- C J Cates
- Bushey Health Centre, Manor View Practice, London Road, Bushey, Watford, Hertfordshire, UK, WD2 2NN.
| | | | | |
Collapse
|
7
|
Kozma CM, Slaton TL, Monz BU, Hodder R, Reese PR. Development and validation of a patient satisfaction and preference questionnaire for inhalation devices. ACTA ACUST UNITED AC 2005; 4:41-52. [PMID: 15725049 DOI: 10.2165/00151829-200504010-00005] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
INTRODUCTION The Patient Satisfaction and Preference Questionnaire (PASAPQ) is a multi-item measure of respiratory inhalation device satisfaction and preference designed to be easily understood and administered to patients with asthma and COPD. This study assessed its validity, reliability and responsiveness and explored the between-group difference in PASAPQ scores that is meaningful. METHODS The field test version was developed using literature, focus groups and expert opinion. Item reduction followed. The assessment of the validity, reliability and responsiveness of the PASAPQ utilized data from two clinical studies comparing devices delivering the same medication, and was performed with pre-specified criteria. A minimally important difference (MID) was estimated using both anchor- and distribution-based approaches. RESULTS Two factors of the PASAPQ, 'performance' and 'convenience', were consistent across studies. Missing and out-of-range data were minimal (<1%) and respondents used a full range of response options. All items correlated most highly with their hypothesized scale and all exceeded the minimum correlation criteria of 0.40. Cronbach's alfa was high (0.87-0.94), providing support for internal reliability for the PASAPQ. Correlations of the overall satisfaction item with the performance domain ranged from 0.78 to 0.91, the convenience domain ranged from 0.54 to 0.71, and the total score ranged from 0.78 to 0.90. These moderate-to-strong correlations provide substantial support for the validity of the PASAPQ domains and total score. Discriminate validity was assessed by calculating PASAPQ scores for patients' ratings of the device that they preferred compared with the other, non-preferred device. The preferred device was rated higher on all satisfaction measures, supporting the ability of the PASAPQ to discriminate between preferred and non-preferred devices. Although a difference of 3 or 4 points may be sufficient to observe a small effect difference between groups, most of the MID estimates were in the 8-10 point range. DISCUSSION AND CONCLUSION Our analyses across asthma, COPD and patients with mixed respiratory disease (with features of both COPD and asthma), study designs and data sets lead us to conclude that the PASAPQ is a practical, valid, reliable and responsive instrument for measuring respiratory device satisfaction. Furthermore, a difference in satisfaction scores between treatment groups of 10 points is, conservatively, a difference that is meaningful to patients.
Collapse
Affiliation(s)
- Chris M Kozma
- College of Pharmacy, University of South Carolina, Columbia, South Carolina, USA
| | | | | | | | | |
Collapse
|
8
|
Adams N, Bestall JM, Lasserson TJ, Jones PW. Inhaled fluticasone versus inhaled beclomethasone or inhaled budesonide for chronic asthma in adults and children. Cochrane Database Syst Rev 2005:CD002310. [PMID: 15846637 DOI: 10.1002/14651858.cd002310.pub3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Beclomethasone dipropionate (BDP) and budesonide (BUD) are commonly prescribed inhaled corticosteroids for the treatment of asthma. Fluticasone propionate (FP) is newer agent with greater potency in in-vitro assays. OBJECTIVES To compare the efficacy and safety of Fluticasone to Beclomethasone or Budesonide in the treatment of chronic asthma. SEARCH STRATEGY We searched the Cochrane Airways Group trial register (January 2004) and reference lists of articles. We contacted trialists and pharmaceutical companies for additional studies and searched abstracts of major respiratory society meetings (1997 to 2003). SELECTION CRITERIA Randomised trials in children and adults comparing Fluticasone to either Beclomethasone or Budesonide in the treatment of chronic asthma. DATA COLLECTION AND ANALYSIS Two reviewers independently assessed articles for inclusion and methodological quality. One reviewer extracted data. Quantitative analyses were undertaken using RevMan analyses 1.0.1. MAIN RESULTS Fifty six studies (12, 119 participants) met the inclusion criteria. Methodological quality was variable. Dose ratio 1:2: FP produced a significantly greater FEV1 (0.14 litres, 95% Confidence Interval (CI) 0.06 to 0.22), morning PEF (11.10 L/min, 95%CI 3.12 to 19.09 L/min) and evening PEF (9.31 L/min, 95%CI 5.12 to 13.5 L/min). This applied to all drug doses, age groups, and delivery devices. No difference between FP and BDP/BUD were seen for trial withdrawals. Symptoms and rescue medication use were widely reported but few trials provided sufficient data for analysis. When given at half the dose of BDP/BUD, FP led to a greater likelihood of pharyngitis. There was no difference in the likelihood of oral candidiasis. Plasma cortisol and 24 hour urinary cortisol was measured frequently but data presentation was limited. Dose ratio 1:1: FP produced a statistically significant difference in am PEF (9.58 L/min (95% CI 5.20 to 13.97)), pm PEF (7.41 L/min (95% CI 2.61 to 12.22)), and FEV1 (0.09 L (0.02 to 0.17)). The effects on exacerbations were mixed. There was an increase in the incidence of hoarseness, but no significant difference in pharyngitis, candidiasis, or cough. AUTHORS' CONCLUSIONS Fluticasone given at half the daily dose of beclomethasone or budesonide leads to small improvements in measures of airway calibre, but it appears to have a higher risk of causing hoarseness when given at the same daily dose. Future studies should attempt to establish the relative efficacy of inhaled steroids delivered with CFC-free propellants.
Collapse
|
9
|
Persson U, Ghatnekar O. Cost-effectiveness analysis of inhaled corticosteroids in asthma: a review of the analytical standards. Respir Med 2003; 97:1-11. [PMID: 12556004 DOI: 10.1053/rmed.2002.1405] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To determine whether published cost-effectiveness studies on inhaled corticosteroids (ICS) in asthma adhered to basic analytical standards as defined in health economic textbooks and in guidelines assessing and comparing efficacy and safety. METHODS Original cost-effectiveness studies published between 1990 and 2000 in general medical or economic journals were reviewed to assess the adherence to five fundamental methodological principles: (1) design of the study, (2) choice of perspective and corresponding costs, (3) choice of outcome measure, (4) marginal cost analysis, and (5) sensitivity analysis and discussion about external validity. For each principle, the studies were ranked as high, medium or low quality. RESULTS Most of the 18 studies included were ranked medium on the first two principles. The studies adhered to a higher degree to the remaining three principles. Only three studies were high ranked in all five principles. The number of principles fulfilled increased over time. Studies comparing pharmaceutical products from competing companies were typically short-term studies, designed for other purposes than health economic analyses, and, in general, did not use therapeutically equivalent dosing. CONCLUSIONS Attention should be drawn to the study design, the weak correspondence between perspective and costs, and especially to the impact of bias in health economic results when comparing different doses of ICSs.
Collapse
Affiliation(s)
- U Persson
- IHE, The Swedish Institute for Health Economics, Lund, Sweden.
| | | |
Collapse
|
10
|
Whitford H, Walters EH, Levvey B, Kotsimbos T, Orsida B, Ward C, Pais M, Reid S, Williams T, Snell G. Addition of inhaled corticosteroids to systemic immunosuppression after lung transplantation: a double-blind, placebo-controlled trial. Transplantation 2002; 73:1793-9. [PMID: 12085003 DOI: 10.1097/00007890-200206150-00016] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND It is postulated that bronchiolitis obliterans syndrome (BOS) is preceded by airway inflammation that has been described even in stable lung transplant recipients. Airway inflammation is known to be suppressed by inhaled steroids in other chronic inflammatory lung diseases, e.g., asthma and chronic obstructive pulmonary disease. BOS is the major cause of morbidity and mortality after lung transplantation. OBJECTIVE To examine the effect of inhaled corticosteroids on the development of BOS in lung transplant recipients. METHODS Thirty patients were recruited and randomized in a double-blind fashion to receive either 750 microg of fluticasone propionate (FP) or an identical-appearing placebo twice daily for 3 months; 20 of this group continued until 2 years posttransplantation. Detailed spirometry was performed regularly throughout the study. RESULTS In the short-term study no differences were found in any examined parameters. In the long-term component of the study no differences were found in the development of neither BOS nor survival. There were minor differences in bronchoalveolar lavage (BAL) lymphocyte percentages. CONCLUSIONS FP is ineffective for the prevention of BOS after lung transplantation despite the airway inflammation that characterizes this condition. Inadequate local delivery, timing of the therapy relative to transplantation and inherent steroid resistance of this condition may explain the negative finding of this study.
Collapse
Affiliation(s)
- Helen Whitford
- Department of Respiratory Medicine, The Alfred Hospital, Commercial Road, Prahran, Victoria, Australia 3181
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Sullivan SD, Weiss KB. Health economics of asthma and rhinitis. II. Assessing the value of interventions. J Allergy Clin Immunol 2001; 107:203-10. [PMID: 11174182 DOI: 10.1067/mai.2001.112851] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Health care providers and payers are being asked to weigh data on the economic impact of new interventions along with clinical evidence when making decisions about the care of patients. The notion of incorporating formal health economic assessments into clinical and resource decisions is a difficult concept for many in the health care sector. However, it is the reality in today's environment. To effectively participate in these ongoing discussions, clinicians and other decision makers must be able to understand and critically assess the evidence on economic impact of medical interventions. This second of 2 articles describes the elements of comparative economic evaluations, reviewing the published literature on asthma and rhinitis in an attempt to critically appraise the studies from the perspective of one who might use data for decision making. Unfortunately, the quality of the economic evidence in these two disease states is not extensive. Until better economic analyses are conducted and made available, the allocation of resources for asthma and allergic rhinitis will continue to primarily rely on expert opinion rather than evidence-based literature.
Collapse
Affiliation(s)
- S D Sullivan
- Department of Pharmacy, University of Washington School of Pharmacy, Seattle, USA
| | | |
Collapse
|
12
|
Cada DJ, Levien T, Baker DE. Budesonide Inhalation Suspension. Hosp Pharm 2001. [DOI: 10.1177/001857870103600206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Each month, subscribers to The Formulary® Monograph Service receive five to six researched monographs on drugs that are newly released or are in late Phase III trials. The monographs are targeted to your Pharmacy and Therapeutics Committee. Subscribers also receive monthly one-page summary monographs on the agents that are useful for agendas and pharmacy/nursing in-services. A comprehensive target drug utilization evaluation (DUE) is also provided each month. The monographs are published in printed form and on diskettes that allow customization. Subscribers to the The Formulary Monograph Service also receive access to a pharmacy bulletin board called The Formulary Information Exchange (The F.I.X). All topics pertinent to clinical pharmacy are discussed on The F.I.X. Through the cooperation of The Formulary, Hospital Pharmacy publishes selected reviews in this column. If you would like information about The Formulary Monograph Service or The F.I.X., call The Formulary at 800-322-4349. The February 2001 Formulary monographs are iron sucrose injection, oxybate sodium, diclofenac sodium gel, tacrolimus ointment, and docosanol. The DUE is on iron sucrose injection.
Collapse
Affiliation(s)
- Dennis J. Cada
- The Formulary; 601 West First Avenue, Spokane, WA 99201-3899
| | - Terri Levien
- Drug Information Pharmacist, Drug Information Center, Washington State University at Spokane; 601 West First Avenue, Spokane, WA 99201-3899
| | - Danial E. Baker
- Drug Information Center and College of Pharmacy, Washington State University at Spokane, 601 West First Avenue, Spokane, WA 99201-3899
| |
Collapse
|
13
|
Cates CJ, Adams N, Bestall J. Holding chambers versus nebulisers for inhaled steroids in chronic asthma. Cochrane Database Syst Rev 2001:CD001491. [PMID: 11405994 DOI: 10.1002/14651858.cd001491] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Inhaled corticosteroids are available in the form of a suspension for nebulisation, although the role of this mode of therapy in the treatment of chronic asthma is still unclear. OBJECTIVES To assess the efficacy and safety of inhaled corticosteroids delivered via nebuliser versus holding chamber for the treatment of chronic asthma. SEARCH STRATEGY We searched the Cochrane Airways Group Trial Register (1999) and reference lists of articles. We contacted the authors of studies and pharmaceutical companies for additional studies and hand-searched the British Journal of Clinical Research, European Journal of Clinical Research and major respiratory society meeting abstracts (1997-1999). SELECTION CRITERIA Randomised controlled trials comparing nebuliser to holding chamber in the delivery of inhaled corticosteroids for the treatment of chronic asthma. All age groups of patients were considered. Two reviewers assessed articles for inclusion; two reviewers independently assessed included studies for methodological quality. DATA COLLECTION AND ANALYSIS One reviewer extracted data; authors were contacted to clarify missing information. Quantitative analyses were undertaken using Review Manager 4.1 with MetaView 3.1. MAIN RESULTS Two studies were selected for inclusion (63 subjects), both concerned adults. Methodological quality was variable. Due to design differences it was not appropriate to pool the studies. The single high quality study compared budesonide 2000-8000 mcg delivered via Pari Inhalier Boy jet nebuliser with inspiration-only inhalation to budesonide 1600 mcg via large volume spacer. The nebuliser delivery led to higher morning peak expiratory flow values (25 L/min p<0.01), higher evening values (30L/min, p<0.01), lower rescue beta2 agonist use and symptom scores compared to the holding chamber delivery. REVIEWER'S CONCLUSIONS Budesonide in high dose delivered by the particular nebuliser used in the only double-blinded study that could be included in this review was more effective than budesonide 1600 mcg via a large volume spacer. However, it is not clear whether this was an effect of nominal dose delivered or delivery system. Cost, compliance and patient preference are important determinants of clinical effectiveness that have not been assessed. Future studies are needed to evaluate the relative effectiveness of inhaled corticosteroids delivered by different combinations of nebuliser/compressor compared to holding chamber. Moreover, further studies assessing these delivery methods are needed in infants and pre-school children, as these are groups that are likely to be considered for treatment with nebulised corticosteroids.
Collapse
Affiliation(s)
- C J Cates
- Dept Physiological Medicine, St George's Hospital Medical School, Cranmer Terrace, London, UK, SW17 ORE.
| | | | | |
Collapse
|
14
|
Menendez R, Stanford RH, Edwards L, Kalberg C, Rickard K. Cost-efficacy analysis of fluticasone propionate versus zafirlukast in patients with persistent asthma. PHARMACOECONOMICS 2001; 19:865-874. [PMID: 11596838 DOI: 10.2165/00019053-200119080-00008] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To compare the relative value of an inhaled corticosteroid, fluticasone propionate 88 microg twice daily, versus an oral leukotriene receptor antagonist, zafirlukast 20 mg twice daily, in patients with persistent asthma currently receiving short acting beta2-agonists alone. STUDY DESIGN A cost-efficacy analysis using resource utilisation and clinical data obtained prospectively from a multicentre, randomised, double-blind, double-dummy, placebo-controlled 12-week clinical trial conducted in the US. PERSPECTIVE Third-party payor. PATIENTS AND METHODS A total of 451 corticosteroid-naive patients with persistent asthma were treated with either fluticasone propionate 88 microg twice daily or zafirlukast 20 mg twice daily. All patients were given salbutamol (albuterol) to be used as rescue medication. Data were examined using intent-to-treat analysis. RESULTS Mean daily per person cost-efficacy ratios using improvement in forced expiratory volume in 1 second (FEV1) [> or = 12% increase from baseline] were $US 3.47 for fluticasone propionate compared with $US 7.81 for zafirlukast (1999 values). The mean daily per person cost-efficacy ratios for symptom-free days obtained were $US 5.51 for fluticasone propionate compared with $US 14.98 for zafirlukast. These cost-efficacy ratios remained in favour of fluticasone propionate after a robust sensitivity analysis. CONCLUSIONS Treatment with fluticasone propionate 88 kg twice daily was the most cost effective treatment compared with zafirlukast 20 mg twice daily in this 12-week clinical trial. This analysis supports the use of fluticasone propionate 88 microg twice daily as first-line treatment in patients with persistent asthma previously treated with short-acting beta2-agonist alone.
Collapse
Affiliation(s)
- R Menendez
- Allergy and Asthma Center of El Paso, Texas 79925, USA.
| | | | | | | | | |
Collapse
|
15
|
Hvizdos KM, Jarvis B. Budesonide inhalation suspension: a review of its use in infants, children and adults with inflammatory respiratory disorders. Drugs 2000; 60:1141-78. [PMID: 11129126 DOI: 10.2165/00003495-200060050-00010] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Budesonide, a topically active corticosteroid, has a broad spectrum of clinically significant local anti-inflammatory effects in patients with inflammatory lung diseases including persistent asthma. In infants and young children with persistent asthma, day- and night-time symptom scores, and the number of days in which beta2-agonist bronchodilators were required, were significantly lower during randomised, double-blind treatment with budesonide inhalation suspension 0.5 to 2 mg/day than placebo in 3 multicentre trials. Significantly fewer children discontinued therapy with budesonide inhalation suspension than with placebo because of worsening asthma symptoms in a study that included children who were receiving inhaled corticosteroids at baseline. Recent evidence indicates that budesonide inhalation suspension is significantly more effective than nebulised sodium cromoglycate in improving control of asthma in young children with persistent asthma. At a dosage of 2 mg/day, budesonide inhalation suspension significantly reduced the number of asthma exacerbations and requirements for systemic corticosteroids in preschool children with severe persistent asthma. In children with acute asthma or wheezing, the preparation was as effective as, or more effective than oral prednisolone in improving symptoms. In children with croup, single 2 or 4mg dosages of budesonide inhalation suspension were significantly more effective than placebo and as effective as oral dexamethasone 0.6 mg/kg or nebulised L-epinephrine (adrenaline) 4mg in alleviating croup symptoms and preventing or reducing the duration of hospitalisation. Early initiation of therapy with budesonide inhalation suspension 1 mg/day appears to reduce the need for mechanical ventilation and decrease overall corticosteroid usage in preterm very low birthweight infants at risk for chronic lung disease. In adults with persistent asthma, budesonide inhalation suspension < or =8 mg/day has been compared with inhaled budesonide 1.6 mg/day and fluticasone propionate 2 mg/day administered by metered dose inhaler. Greater improvements in asthma control occurred in patients during treatment with budesonide inhalation suspension than with budesonide via metered dose inhaler, whereas fluticasone propionate produced greater increases in morning peak expiratory flow rates than nebulised budesonide. Several small studies suggest that the preparation has an oral corticosteroid-sparing effect in adults with persistent asthma and that it may be as effective as oral corticosteroids during acute exacerbations of asthma or chronic obstructive pulmonary disease. The frequency of adverse events was similar in children receiving budesonide inhalation suspension 0.25 to 2 mg/day or placebo in 12-week studies. During treatment with budesonide inhalation suspension 0.5 to 1 mg/day in 3 nonblind 52-week studies, growth velocity in children was generally unaffected; however, a small but statistically significant decrease in growth velocity was detected in children who were not using inhaled corticosteroids prior to the introduction of budesonide inhalation suspension. Hypothalamic-pituitary-adrenal axis function was not affected by short (12 weeks) or long (52 weeks) term treatment with nebulised budesonide. In conclusion, budesonide inhalation suspension is the most widely available nebulised corticosteroid, and in the US is the only inhaled corticosteroid indicated in children aged > or =1 year with persistent asthma. The preparation is suitable for use in infants, children and adults with persistent asthma and in infants and children with croup.
Collapse
Affiliation(s)
- K M Hvizdos
- Adis International Limited, Auckland, New Zealand.
| | | |
Collapse
|