1
|
Lee C, Dennett AM, Pinson JA, Lewis AK. Caffeine consumed prior to cardiac stress testing may affect diagnostic accuracy of nuclear medicine myocardial imaging of myocardial ischemia: A systematic review and meta-analysis. J Med Imaging Radiat Sci 2024; 55:134-145. [PMID: 38233285 DOI: 10.1016/j.jmir.2023.12.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 12/15/2023] [Accepted: 12/21/2023] [Indexed: 01/19/2024]
Abstract
BACKGROUND Myocardial perfusion imaging (MPI) is a well-established, non-invasive imaging procedure for the diagnosis and evaluation of patients with known or suspected coronary artery disease. With the increasing use of pharmacologic stress agents in myocardial perfusion imaging, strict preparation, including caffeine abstinence, is required. The aim of this review was to determine the effect of caffeine consumed prior to nuclear cardiac stress testing on the diagnostic accuracy. METHODS Medline, Embase and CINAHL were searched from the earliest available time until August 2022. Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies version 2. Data pertaining to diagnostic accuracy were analysed using meta-analysis where appropriate and overall certainty of evidence evaluated using the Grades of Research, Assessment, Development and Evaluation approach. RESULTS Six studies (307 participants) from a yield of 735 articles were identified. Meta-analysis of two studies found no difference in the left ventricular ejection fraction of patients pre and post caffeine consumption (MD -0.31 %, 95% CI -4.32% to 3.7%). Meta-analysis of three studies found there was uncertainty as to whether caffeine consumption affected reversibility (MD -2.16 segments 95% CI -4.61 to 0.28) and descriptive summary of three studies found mixed results for size of stress defects. CONCLUSION The low quality evidence synthesized in this systematic review suggests caffeine may affect the diagnostic accuracy in myocardial perfusion imaging for ischemia detection in patients with chest pain and intermediate-to-high risk of coronary artery disease.
Collapse
Affiliation(s)
- Christine Lee
- Department of Nuclear Medicine, Eastern Health, Box Hill Hospital, Box Hill, Melbourne, Australia.
| | - Amy M Dennett
- Eastern Health, Allied Health Clinical Research Office, Box Hill, Australia; School of Allied Health Human Services and Sport, La Trobe University, Bundoora Australia
| | - Jo-Anne Pinson
- Sir Peter MacCallum Department of Oncology, The Radiopharmaceutical Research Laboratory, The Peter MacCallum Cancer Centre, The University of Melbourne, Melbourne, Australia; Medicinal Chemistry, Faculty of Pharmacy and Pharmaceutical Sciences, Monash Institute of Pharmaceutical Sciences, Monash University (Parkville Campus), Parkville, Australia
| | - Annie K Lewis
- Eastern Health, Allied Health Clinical Research Office, Box Hill, Australia; School of Allied Health Human Services and Sport, La Trobe University, Bundoora Australia
| |
Collapse
|
2
|
Case JA, Courter SA, McGhie AI, Patel KK, Sperry BW, Moloney E, Case KO, Burgett EV, Bateman TM. Accurate and efficient rapid acquisition early post-injection stress-first CZT SPECT myocardial perfusion imaging with tetrofosmin and attenuation correction. J Nucl Cardiol 2023; 30:2644-2654. [PMID: 37464251 DOI: 10.1007/s12350-023-03336-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 06/01/2023] [Indexed: 07/20/2023]
Abstract
INTRODUCTION Myocardial perfusion imaging (MPI) protocols have not changed significantly despite advances in instrumentation and software. We compared an early post-injection, stress-first SPECT protocol to standard delayed imaging. METHODS 95 patients referred for SPECT MPI were imaged upright and supine on a Spectrum Dynamics D-SPECT CZT system with CT attenuation correction. Patients received injection of 99mTc tetrofosmin at peak of regadenoson stress and were imaged. Early post-stress (mean 17 ± 2 minutes) and Standard 1-h delay (mean 61 ± 13 min). Three blinded readers evaluated images for overall interpretation, perceived need for rest imaging, image quality, and reader confidence. Laboratory efficiency was also evaluated. RESULTS Blinded readers had the same response for the need for rest in 77.9% of studies. Studies also had the same interpretation in 89.5% of studies. Reader confidence was high (86.0% (Early) and 90.3% (Standard p = 0.52. Image quality was good or excellent in 87.4% Early vs 96.8% Standard (p = 0.09). Time between patient check-in and end of stress imaging was 104 ± (Standard) to 60 ± 18 minutes (Early) (p < 0.001). CONCLUSION Early post-injection stress-only imaging using CZT SPECT/CT appears promising with Tc-99m tetrofosmin with similar image quality, reader confidence, diagnosis, and need for a rest scan.
Collapse
Affiliation(s)
- James A Case
- Cardiovascular Imaging Technologies, Kansas City, MO, USA.
| | | | - AIain McGhie
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Krishna K Patel
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
- Icahn School of Medicine at Mount Sinai Medical Center, New York, New York, USA
| | - Brett W Sperry
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Erin Moloney
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Katrina O Case
- Cardiovascular Imaging Technologies, Kansas City, MO, USA
- Boston University, Boston, MA, USA
| | - Eric V Burgett
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Timothy M Bateman
- Cardiovascular Imaging Technologies, Kansas City, MO, USA
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| |
Collapse
|
3
|
Duvall WL, Case J, Lundbye J, Cerqueira M. Efficiency of tetrofosmin versus sestamibi achieved through shorter injection-to-imaging times: A systematic review of the literature. J Nucl Cardiol 2021; 28:1381-1394. [PMID: 32236839 PMCID: PMC8421307 DOI: 10.1007/s12350-020-02093-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 02/19/2020] [Indexed: 11/20/2022]
Abstract
Based on superior image quality, more accurate gated images, and lower radiation exposure to patients, Technetium-99m (Tc-99m) based tracers are preferred over Thallium-201 for SPECT myocardial perfusion imaging. The two Tc-99m tracers, sestamibi and tetrofosmin, have many similar characteristics but there are differences in blood and liver clearance rates, as well as the recommended time after injection for imaging to achieve optimal image quality. Because published peer-reviewed studies examining optimal times between injection and imaging are limited, it can be difficult to identify evidence-based opportunities to optimize imaging protocols. Using systematic literature review methods, this study was designed to identify and consolidate the available evidence on the use of sestamibi compared to tetrofosmin for variable injection to imaging times in regard to test efficiency, including test length and re-scan rates, and image quality, including overall quality and cardiac to extra-cardiac ratios. The composite of this data shows that earlier imaging with tetrofosmin is equivalent to later imaging with sestamibi when assessing subjective image quality or when quantifying heart-to-extra-cardiac ratios. Image quality and heart-to-extra-cardiac ratios comparing early versus later imaging with tetrofosmin were comparable if not equivalent to each other. The equivalency of the imaging quality occurs with 15 minutes (on average) earlier imaging compared to sestamibi and 30 minutes compared to standard time tetrofosmin. The subjective findings of equivalent image quality are also shown with objective measurements of heart-to-extra-cardiac ratios. In this review, the significantly shorter injection-to-acquisition times with tetrofosmin compared to sestamibi resulted in better efficiency and less waiting times for patients; in addition, significantly higher re-scan rates with sestamibi compared to tetrofosmin due to hepatic activity contributed to better throughput with tetrofosmin.
Collapse
Affiliation(s)
- W Lane Duvall
- Hartford Hospital, Heart and Vascular Institute, 80 Seymour Street, Hartford, CT, 06102, USA.
| | - James Case
- Cardiovascular Imaging Technologies, Kansas City, MO, USA
| | - Justin Lundbye
- The Greater Waterbury Health Network, Waterbury, CT, USA
| | - Manuel Cerqueira
- Department of Nuclear Medicine, Department of Cardiovascular Imaging, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
4
|
Iking J, Klose J, Staniszewska M, Fendler WP, Herrmann K, Rischpler C. Imaging inflammation after myocardial infarction: implications for prognosis and therapeutic guidance. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF RADIOPHARMACEUTICAL CHEMISTRY AND BIOLOGY 2020; 64:35-50. [PMID: 32077669 DOI: 10.23736/s1824-4785.20.03232-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Inflammation after myocardial infarction (MI) has been in the focus of cardiovascular research for several years as it influences the remodeling process of the ischemic heart and thereby critically determines the clinical outcome of the patient. Today, it is well appreciated that inflammation is a crucial necessity for the initiation of the natural wound healing process; however, excessive inflammation can have detrimental effects and might result in adverse ventricular remodeling which is associated with an increased risk of heart failure. Newly emerged imaging techniques facilitate the non-invasive assessment of immune cell infiltration into the ischemic myocardium and can provide greater insight into the underlying complex and dynamic repair mechanisms. Molecular imaging of inflammation in the context of MI may help with stratification of patients at high risk of adverse ventricular remodeling post-MI which may be of diagnostic, therapeutic, and prognostic value. Novel radiopharmaceuticals may additionally provide a way to combine patient monitoring and therapy. In spite of great advances in recent years in the field of imaging sciences, clinicians still need to overcome some obstacles to a wider implementation of inflammation imaging post-MI. This review focuses on inflammation as a molecular imaging target and its potential implication in prognosis and therapeutic guidance.
Collapse
Affiliation(s)
- Janette Iking
- Department of Nuclear Medicine, University Hospital Essen, Essen, Germany.,Department of Cardiology I for Coronary and Peripheral Vascular Disease, and Heart Failure, University Hospital Münster, Münster, Germany
| | - Jasmin Klose
- Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
| | | | - Wolfgang P Fendler
- Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
| | - Ken Herrmann
- Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
| | | |
Collapse
|
5
|
Diagnostic and Prognostic Value of Gated SPECT MIBI Early Post-Stress Imaging in Patients With Intermediate Duke Treadmill Score. Clin Nucl Med 2013; 38:784-9. [DOI: 10.1097/rlu.0b013e31829f8e5a] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
6
|
Low-dose single acquisition rest (99m)Tc/stress (201)Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation. Eur J Nucl Med Mol Imaging 2013; 41:536-47. [PMID: 24030670 DOI: 10.1007/s00259-013-2551-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Accepted: 08/14/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE We developed and tested a single acquisition rest (99m)Tc-sestamibi/stress (201)Tl dual isotope protocol (SDI) with the intention of improving the clinical workflow and patient comfort of myocardial perfusion single photon emission computed tomography (SPECT). METHODS The technical feasibility of SDI was evaluated by a series of anthropomorphic phantom studies on a standard SPECT camera. The attenuation map was created by a moving transmission line source. Iterative reconstruction including attenuation correction, resolution recovery and Monte Carlo simulation of scatter was used for simultaneous reconstruction of dual tracer distribution. For clinical evaluation, patient studies were compared to stress (99m)Tc and rest (99m)Tc reference images acquired in a 2-day protocol. Clinical follow-up examinations like coronary angiography (CAG) and fractional flow reserve (FFR) were included in the assessment if available. RESULTS Phantom studies demonstrated the technical feasibility of SDI. Artificial lesions inserted in the phantom mimicking ischaemia could be clearly identified. In 51/53 patients, the image quality was adequate for clinical evaluation. For the remaining two obese patients with body mass index > 32 the injected (201)Tl dose of 74 MBq was insufficient for clinical assessment. In answer to this the (201)Tl dose was adapted for obese patients in the rest of the study. In 31 patients, SDI and (99m)Tc reference images resulted in equivalent clinical assessment. Significant differences were found in 20 patients. In 18 of these 20 patients additional examinations were available. In 15 patients the diagnosis based on the SDI images was confirmed by the results of CAG or FFR. In these patients the SDI images were more accurate than the (99m)Tc reference study. In three patients minor ischaemic lesions were detected by SDI but were not confirmed by CAG. In one of these cases this was probably caused by pronounced apical thinning. For two patients no relevant clinical follow-up information was available for evaluation. CONCLUSION The proposed SDI protocol has the potential to improve clinical workflow and patient comfort and suggests improved accuracy as demonstrated in the clinical feasibility study.
Collapse
|
7
|
Iskandar A, Limone B, Parker MW, Perugini A, Kim H, Jones C, Calamari B, Coleman CI, Heller GV. Gender differences in the diagnostic accuracy of SPECT myocardial perfusion imaging: a bivariate meta-analysis. J Nucl Cardiol 2013; 20:53-63. [PMID: 23149886 DOI: 10.1007/s12350-012-9646-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2012] [Accepted: 10/19/2012] [Indexed: 12/31/2022]
Abstract
BACKGROUND It remains controversial whether the diagnostic accuracy of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) is different in men as compared to women. We performed a meta-analysis to investigate gender differences of SPECT MPI for the diagnosis of CAD (≥50% stenosis). METHOD Two investigators independently performed a systematic review of the MEDLINE and EMBASE databases from inception through January 2012 for English-language studies determining the diagnostic accuracy of SPECT MPI. We included prospective studies that compared SPECT MPI with conventional coronary angiography which provided sufficient data to calculate gender-specific true and false positives and negatives. Data from studies evaluating <20 patients of one gender were excluded. Bivariate meta-analysis was used to create summary receiver operating curves. RESULTS Twenty-six studies met inclusion criteria, representing 1,148 women and 1,142 men. Bivariate meta-analysis yielded a mean sensitivity and specificity of 84.2% (95% confidence interval [CI] 78.7%-88.6%) and 78.7% (CI 70.0%-85.3%) for SPECT MPI in women and 89.1% (CI 84.0%-92.7%) and 71.2% (CI 60.8%-79.8%) for SPECT MPI in men. There was no significant difference in the sensitivity (P = .15) or specificity (P = .23) between male and female subjects. CONCLUSION In a bivariate meta-analysis of the available literature, the diagnostic accuracy of SPECT MPI is similar for both men and women.
Collapse
Affiliation(s)
- Aline Iskandar
- Department of Medicine, University of Connecticut School of Medicine, Farmington, CT, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Philippe L, Mérino B, Blaire T, Bailliez A, Casset-Senon D, Levy M, Halley A, Divry G. Tetrofosmin early time gated post-stress single-photon emission computed tomography imaging: feasibility and potential benefits. J Nucl Cardiol 2011; 18:62-72. [PMID: 21063927 PMCID: PMC3032180 DOI: 10.1007/s12350-010-9302-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2009] [Accepted: 09/19/2010] [Indexed: 11/29/2022]
Abstract
BACKGROUND The purpose of this study is to evaluate the feasibility, the image quality, and the clinical relevance of an early gated post-stress (GPS) single-photon emission computed tomography (SPECT) tetrofosmin (Myoview™-GE Healthcare) acquisition protocol. Time delay between myocardial technetium-labeled tracer administration and SPECT acquisition is usually about 30 minutes after stress, and 45 to 60 minutes at rest: because of the absence of significant redistribution, perfusion images are related to stress even 30 minutes after stress injection, while function and thickening data obtained with gated acquisition 30 minutes after stress are mainly related to rest conditions. METHODS 194 patients were prospectively included and analyzed, in a multicenter registry. Three gated-SPECT 99(m)Tc-Tetrofosmin studies were performed per patient: GPS-SPECT, 30 minutes post-stress (GS30), and at rest (GR30). RESULTS GPS image quality was excellent/good (93.9%), and similar to GS30 images (96.6%). The presence of adjacent myocardial sub-diaphragmatic activity on GPS images was similar to GS30 images (24% vs 22%), and less frequent than on GR30 images (31%). For perfusion, thickening, and motion scores, there was no significant difference between early and 30 minute post-stress in the global patient population, but significant differences were observed between GPS and GS30 for LVEF (65% ± 15% vs 63% ± 14%). In the ischemic patients, with the stress-rest protocol, the perfusion score was 14.2 on GPS images and 12.4 on GS30 images (P = .002). CONCLUSIONS Tetrofosmin early GPS-SPECT is feasible without impairment of image quality (better count rate). Ischemic defect size on early post-stress images is slightly more pronounced than at 30 minutes: this could modify therapeutic decision. This technique produces reliable function information during early post-stress period, and might be useful for disclosing transient motion abnormalities.
Collapse
|
9
|
Riou LM, Broisat A. Novel SPECT perfusion imaging agents with improved myocardial or liver kinetics: experimental studies and the need for clinical evaluation. J Nucl Cardiol 2010; 17:771-4. [PMID: 20683788 DOI: 10.1007/s12350-010-9275-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
10
|
Kaneko K, Ito M, Takanashi T, Hashizume E, Owashi K, Kaneko H, Ide Y, Oguma M. Computed tomography and scintigraphy vs. cardiac catheterization for coronary disease screening prior to noncardiac surgery. Intern Med 2010; 49:1703-10. [PMID: 20720346 DOI: 10.2169/internalmedicine.49.3507] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
OBJECTIVE The goal of this study was to investigate the utility of multidetector-row computed tomography (MDCT) and adenosine triphosphate stress cardiac single photon emission computed tomography (ATP-SPECT) in evaluating coronary artery disease (CAD) in patients scheduled for non-cardiac surgery. PATIENTS AND METHODS We routinely performed echocardiography and exercise stress electrocardiography as preoperative cardiac screening examinations for patients scheduled for non-cardiac surgery under general anesthesia. Of 848 consecutive preoperative patients (Non-invasive Group), 49 patients with abnormalities of these screening examinations had MDCT and ATP-SPECT. Of 809 consecutive preoperative patients studied at an earlier time (Invasive Group), 58 patients with abnormalities of these screening examinations had cardiac catheterization as an additional cardiac examination. RESULTS The number of patients in the non-invasive and invasive subgroups having additional screening examinations was comparable, and there was no significant difference in perioperative cardiac events between the two subgroups. Based on results of the additional tests in the two subgroups, preoperative prophylactic invasive treatment for CAD was carried out in a small number of patients, again with no significant differences between the groups. However, total medical expenses for the additional cardiac examinations were significantly reduced in the non-invasive subgroup compared with the invasive subgroup (140,030+/-34,800 vs. 187,170+/-26,120 yen, respectively, p=0.0002). CONCLUSION Non-invasive examination prior to noncardiac surgery using MDCT and ATP-SPECT in a subgroup of patients suspected of having CAD appears to be a useful screening procedure. Compared with invasive cardiac catheterization, CT testing has comparable diagnostic utility without an increase in perioperative cardiac events, and in addition, it has an improved cost-benefit profile.
Collapse
Affiliation(s)
- Kazuyoshi Kaneko
- Department of Internal Medicine, Municipal Sakata Hospital, Sakata, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Petretta M, Costanzo P, Acampa W, Imbriaco M, Ferro A, Filardi PP, Cuocolo A. Noninvasive assessment of coronary anatomy and myocardial perfusion: going toward an integrated imaging approach. J Cardiovasc Med (Hagerstown) 2008; 9:977-86. [PMID: 18799959 DOI: 10.2459/jcm.0b013e328306f311] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Many noninvasive imaging techniques are available for the evaluation of patients with known or suspected chronic coronary artery disease. Among these, computed tomography-based techniques allow the quantification of coronary atherosclerotic calcium and noninvasive imaging of coronary arteries, whereas nuclear cardiology is the most widely used noninvasive approach for the assessment of myocardial perfusion. The available single-photon emission computed tomography flow agents are characterized by a cardiac uptake proportional to myocardial blood flow. In addition, different positron emission tomography tracers may be used for the quantitative measurement of myocardial blood flow and coronary flow reserve. Extensive research is currently being performed in the development of noninvasive coronary angiography and myocardial perfusion imaging using cardiac magnetic resonance. Finally, new multimodality imaging systems have been recently developed, bringing together anatomical and functional information. This review sought to provide a description of the relative merits of noninvasive imaging techniques in the assessment of coronary anatomy and myocardial perfusion in patients with known or suspected coronary artery disease.
Collapse
Affiliation(s)
- Mario Petretta
- Department of Clinical Medicine, Cardiovascular and Immunological Sciences, University Federico II, Italy
| | | | | | | | | | | | | |
Collapse
|
12
|
|
13
|
Adenosine Tc-99m Tetrofosmin SPECT in Differentiation of Ischemic From Nonischemic Cardiomyopathy in Patients With LV Systolic Dysfunction. Clin Nucl Med 2008; 33:459-63. [DOI: 10.1097/rlu.0b013e3181779271] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
14
|
Adams GL, Shaw LK, Tuttle RH, Hanson MW, Pagnanelli R, Borges-Neto S. Prediction of mortality in patients with coronary artery disease undergoing vasodilator stress testing: A comparison between 99mTc-tetrofosmin and 99mTc-sestamibi. Nucl Med Commun 2007; 28:457-63. [PMID: 17460536 DOI: 10.1097/mnm.0b013e328174442d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the prognostic ability of the imaging agents 99mTc-sestamibi versus 99mTc-tetrofosmin to predict mortality outcomes in patients with documented coronary artery disease and undergoing vasodilator stress testing. MATERIALS AND METHODS The study included 2147 consecutive patients who underwent rest and stress single photon emission computed tomographic (SPECT) examination with either 99mTc-sestamibi (n=1128) or 99mTc-tetrofosmin (n=1019). Information relating to all-cause death and cardiovascular death was collected over a 4-year study period. Unadjusted Kaplan-Meier estimates were compared for the two imaging agents. Cox proportional hazard models were examined to determine the incremental contribution of SPECT sum stress score (SSS) and the imaging agent after adjusting for clinical and demographic characteristics. Additionally, the interaction between SSS and agent was examined to determine if the effect of SSS on prognosis was different for the two agents. RESULTS Vasodilator agents were used for stress testing in all patients who received 99mTc-tetrofosmin and 99mTc-sestamibi. Despite differences in patient risk factors Kaplan-Meier estimates were similar for the two groups of patients. Resulting P-values for differences between models for the end points of (1) death from any cause and (2) cardiovascular death showed that SSS combined with clinical index was significantly better than a model that adjusted for only baseline characteristics (P<0.0001 for both endpoints). The addition of imaging agent (99mTc-tetrofosmin or 99mTc-sestamibi) to the model containing both SSS and the clinical characteristics did not show further significant improvement (P=0.62, P=0.96 for death from any cause and cardiovascular death, respectively). CONCLUSION The type of clinically available 99mTc-labelled myocardial perfusion agents did not affect interpretation of results for prognostic assessment.
Collapse
Affiliation(s)
- George L Adams
- Department of Medicine (Cardiology), Duke University Medical Center, Durham, North Carolina 27710, USA
| | | | | | | | | | | |
Collapse
|
15
|
Manka-Waluch A, Palmedo H, Reinhardt MJ, Joe AY, Manka C, Guhlke S, Biersack HJ, Bucerius J. Myocardial uptake characteristics of three 99mTc-labeled tracers for myocardial perfusion imaging one hour after rest injection. Ann Nucl Med 2007; 20:663-70. [PMID: 17385304 DOI: 10.1007/bf02984677] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE 99mTc-tetrofosmin and 99mTc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a 99mTc-MIBI preparation from a different manufacturer (99mTc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of 99mTc-tetrofosmin as well as of two different 99mTc-labeled MIBI tracers with regard to differences in imaging quality under resting conditions. METHODS Sixty patients (mean age 63.8 years +/- 1.25) with known or suspected coronary artery disease but without evidence of rest-ischemia were included. Twenty patients in each group were examined by a two-day-rest-stress protocol using the three 99mTc-labeled tracers. Visual analysis of all images was performed by two experienced physicians blinded with regard to the applied tracer. Regions of interest (ROI) were defined over the heart, lung and whole body only in the rest imaging in order to calculate heart-to-lung, lung-to-whole body-, and heart-to-whole body-ratios. RESULTS The heart-to-lung ratio was statistically significant higher for 99mTc-cardiospect-MIBI as compared to 99mTc-sestamibi as well as to 99mTc-tetrofosmin. Furthermore, a significantly higher heart-to-lung ratio was found for 99mTc-sestamibi as compared to 99mTc-tetrofosmin. The heart-to-whole body-ratio and the lung-to-whole body-ratio were equivalent between all tracers. Visual analysis revealed only slight differences regarding image quality between all tracers. CONCLUSIONS ROI analysis surprisingly revealed a significant higher myocardial uptake and consequently a higher heart-to-lung ratio for 99mTc-cardiospect-MIBI. Whether this leads to a better visual image quality has to be evaluated in future studies with larger study populations as well as semiquantitative segmental analysis of the myocardial perfusion images.
Collapse
|
16
|
Hambÿe ASE, Delsarte P, Vervaet AM. Influence of the different biokinetics of sestamibi and tetrofosmin on the interpretation of myocardial perfusion imaging in daily practice. Nucl Med Commun 2007; 28:383-90. [PMID: 17414888 DOI: 10.1097/mnm.0b013e3280e40d85] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
AIM Digestive activity can interfere with the interpretation of myocardial perfusion single photon emission computed tomography using sestamibi or tetrofosmin. Compared with sestamibi, the liver clearance of tetrofosmin is more rapid, but its absolute cardiac uptake is lower. In this study, the activity of sestamibi and tetrofosmin was quantified after exercise or pharmacological stress and at rest to objectify the biokinetic differences and to evaluate whether there is a correlation between quantitative measurements and the visual assessment of image quality. METHODS Left ventricular activity and five ratios (R1-R5) of cardiac to adjacent extra-cardiac activity were quantified in 204 sestamibi (68 exercise stress/56 pharmacological stress/80 rest) and 221 tetrofosmin (67 exercise stress/59 pharmacological stress/95 rest) studies. Image quality was assessed by a three-point score (1, good; 2, moderate; 3, poor) and correlated with the heart to left supra-diaphragmatic region (R1) and heart to right supra-diaphragmatic region (R2) ratios. RESULTS The mean left ventricular activity was higher for sestamibi, especially at rest (sestamibi, 0.21+/-0.05 counts/pixel/injected MBq; tetrofosmin, 0.16+/-0.042 counts/pixel/injected MBq; P<0.001). By contrast, most ratios were higher with tetrofosmin, particularly for the exercise stress and rest studies. Using the three-point quality scoring, more sestamibi than tetrofosmin studies were scored as 3 (12.2% versus 6.3%), also particularly for the exercise stress and rest studies. A highly significant relationship was found between decreasing R1 and R2 and an increasing quality score, regardless of the radiopharmaceutical used (P values between 0.02 and <0.001). CONCLUSIONS Despite a lower cardiac uptake, the more rapid liver clearance of tetrofosmin than sestamibi significantly improves the ratios of cardiac to digestive activity, especially after exercise or at rest. These quantitative differences in biokinetics result in less poor scans with tetrofosmin in daily practice.
Collapse
|
17
|
Matsumoto N, Sato Y, Suzuki Y, Yoda S, Kunimasa T, Kato M, Tadehara F, Lewin HC, Hyun MC, Saito S. Usefulness of rapid low-dose/high-dose 1-day 99mTc-sestamibi ECG-gated myocardial perfusion single-photon emission computed tomography. Circ J 2007; 70:1585-9. [PMID: 17127804 DOI: 10.1253/circj.70.1585] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND The clinical usefulness of a rapid rest low-dose/stress high-dose (dose ratio =1:5) (99m)Tc-sestamibi myocardial perfusion single-photon emission computed tomography (SPECT) protocol for the detection of coronary artery disease was evaluated. METHODS AND RESULTS In 89 patients, rest images were obtained immediately after the injection of (99m)Tc-sestamibi (256.1+/-28.4 MBq) followed by drinking water (400 ml). Exercise or vasodilator stress test was performed immediately after the completion of rest imaging with the injection of (99m)Tc-sestamibi (1312.3 +/-167.6 MBq). Prior to the post-stress imaging, patients were asked again to drink water (400 ml) in order to eliminate subdiaphragmatic tracer activity. The myocardial count ratio (stress/rest) of (99m)Tc-sestamibi was calculated. Image quality was scored using a 4-point scale system (4= excellent, 3= good, 2= poor, 1= unacceptable). Coronary angiography was performed in 56 patients within 1 month of the SPECT scan. All patients successfully performed the protocol and total examination time was 108+/-7 min. The myocardial count ratio of (99m)Tc-sestamibi was always greater than 6. The image quality was satisfactory both at rest (3.4+/-0.9) and after stress (3.9+/-0.2). The sensitivity and specificity to detect coronary artery stenosis >50% was 84% and 97%, respectively. CONCLUSIONS This rapid one-day (99m)Tc-sestamibi protocol provides adequate image quality and diagnostic accuracy for detecting coronary artery disease.
Collapse
Affiliation(s)
- Naoya Matsumoto
- Department of Cardiology, Nihon University School of Medicine, Tokyo, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
McGhie AI, Gould KL, Willerson JT. Nuclear Cardiology. CARDIOVASCULAR MEDICINE 2007. [DOI: 10.1007/978-1-84628-715-2_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
|
19
|
Abstract
Nuclear cardiology has made significant advances since the first reports of planar scintigraphy for the evaluation of left ventricular perfusion and function. While the current "state of the art" of gated myocardial perfusion single-photon emission computed tomographic (SPECT) imaging offers invaluable diagnostic and prognostic information for the evaluation of patients with suspected or known coronary artery disease (CAD), advances in the cellular and molecular biology of the cardiovascular system have helped to usher in a new modality in nuclear cardiology, namely, molecular imaging. In this review, we will discuss the current state of the art in nuclear cardiology, which includes SPECT and positron emission tomographic evaluation of myocardial perfusion, evaluation of left ventricular function by gated myocardial perfusion SPECT and gated blood pool SPECT, and the evaluation of myocardial viability with PET and SPECT methods. In addition, we will discuss the future of nuclear cardiology and the role that molecular imaging will play in the early detection of CAD at the level of the vulnerable plaque, the evaluation of cardiac remodeling, and monitoring of important new therapies including gene therapy and stem cell therapy.
Collapse
|
20
|
Matsunari I, Taki J, Nakajima K, Tonami N. (99m)Tc-tetrofosmin as a prognostic agent? Eur J Nucl Med Mol Imaging 2005; 33:1-3. [PMID: 16292581 DOI: 10.1007/s00259-005-1881-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
21
|
Dilsizian V, Bateman TM, Bergmann SR, Des Prez R, Magram MY, Goodbody AE, Babich JW, Udelson JE. Metabolic Imaging With β-Methyl-
p
-[
123
I]-Iodophenyl-Pentadecanoic Acid Identifies Ischemic Memory After Demand Ischemia. Circulation 2005; 112:2169-74. [PMID: 16186423 DOI: 10.1161/circulationaha.104.530428] [Citation(s) in RCA: 146] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background—
After myocardial ischemia, prolonged suppression of fatty acid metabolism may persist despite restoration of blood flow, which is called metabolic stunning. We hypothesized that a branched-chain fatty acid, β-methyl-
p
-[
123
I]-iodophenyl-pentadecanoic acid (BMIPP), might identify the presence of myocardial ischemia late after demand ischemia at rest up to 30 hours later.
Methods and Results—
In 32 patients with exercise-induced ischemia on thallium SPECT, BMIPP was injected at rest within 30 hours of ischemia. SPECT images were acquired beginning 10 minutes after injection (early) and again 30 minutes after injection (delayed). Thallium and BMIPP SPECT data were read separately by 3 observers blinded to other imaging and clinical data. Agreement between BMIPP and thallium data for the presence of an abnormality on the patient level was 91% (95% CI, 75 to 98) for the early BMIPP data and 94% (95% CI, 79 to 99) for the delayed BMIPP data. Agreement between delayed BMIPP and thallium was 95% among 21 patients studied on the same day, a mean of 6.2±1.4 hours after exercise-induced ischemia, and 91% among the 11 patients studied on the next calendar day, a mean of 24.9±2.6 hours after ischemia (
P
=NS). The magnitude of resting BMIPP metabolic defect by semiquantitative visual analysis was correlated to the magnitude of exercise-induced thallium perfusion defect (
r
=0.6,
P
<0.001 for early BMIPP;
r
=0.5,
P
=0.005 for delayed BMIPP).
Conclusions—
Metabolic imaging with BMIPP identifies patients with recent exercise-induced myocardial ischemia. These findings support the concept that BMIPP imaging can successfully demonstrate the metabolic imprint of a stress-induced ischemic episode, also known as ischemic memory.
Collapse
Affiliation(s)
- Vasken Dilsizian
- Division of Nuclear Medicine, University of Maryland Hospital and School of Medicine, Baltimore, MD 21201-1595, USA.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Slart RHJA, Bax JJ, Sluiter WJ, van Veldhuisen DJ, Jager PL. Added value of attenuation-corrected Tc-99m tetrofosmin SPECT for the detection of myocardial viability: comparison with FDG SPECT. J Nucl Cardiol 2004; 11:689-96. [PMID: 15592192 DOI: 10.1016/j.nuclcard.2004.06.131] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND The aim of this study was to evaluate the value of attenuation correction of technetium 99m tetrofosmin single photon emission computed tomography (SPECT) imaging for the detection of myocardial viability. METHODS AND RESULTS A head-to-head comparison between resting Tc-99m tetrofosmin SPECT and fluorine 18 fluorodeoxyglucose (FDG) SPECT was performed. Both the noncorrected and attenuation-corrected Tc-99m tetrofosmin SPECT images were compared with the FDG images that served as the reference for viability. Consecutive patients (n = 33) with chronic coronary artery disease and left ventricular dysfunction were included. Segmental Tc-99m tetrofosmin and FDG data were displayed in polar maps (17-segment model), and the segments were normalized to peak activity by use of the 4D-MSPECT software program. Segments with normalized FDG activity greater than 50% were considered viable. A similar cutoff value to assess viability was used for the noncorrected and attenuation-corrected Tc-99m tetrofosmin images. Regional contractile function was determined from the gated Tc-99m tetrofosmin images and scored as normokinesia, hypokinesia, or akinesia/dyskinesia. Of all segments, 482 (85%) were viable on FDG SPECT. Of these, 427 (89%) were classified as viable with noncorrected Tc-99m tetrofosmin. Thus 55 (11%) were underestimated with noncorrected Tc-99m tetrofosmin SPECT; these segments were mainly located in the inferior and inferoseptal regions. Attenuation correction changed the classification of 39 (70%) of the underestimated segments to viable. By use of attenuation correction, the agreement between Tc-99m tetrofosmin and FDG imaging improved from 84% to 90%. Similar observations were made when the analysis was restricted to the dysfunctional segments. CONCLUSION The addition of attenuation correction to Tc-99m tetrofosmin SPECT significantly improved detection of myocardial viability in patients with chronic coronary artery disease, although minimal underestimation of viability remained as compared with FDG SPECT imaging.
Collapse
Affiliation(s)
- Riemer H J A Slart
- Department of Nuclear Medicine, Groningen University Medical Center, Hanzeplein 1, PO Box 30001, 9700 RB Groningen, The Netherlands.
| | | | | | | | | |
Collapse
|
23
|
Borges-Neto S, Tuttle RH, Shaw LK, Smith WT, Jain D, Coleman RE, Whellan D. Outcome Prediction in Patients at High Risk for Coronary Artery Disease: Comparison between99mTc Tetrofosmin and99mTc Sestamibi. Radiology 2004; 232:58-65. [PMID: 15220493 DOI: 10.1148/radiol.2321030279] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To determine if there was any difference in the ability of physicians to predict prognosis with technetium 99m ((99m)Tc) sestamibi or (99m)Tc tetrofosmin in a large consecutive series of patients at high risk for coronary artery disease who underwent coronary angiography. MATERIALS AND METHODS This study included 1,818 consecutive patients who underwent a rest and stress single photon emission computed tomographic (SPECT) examination with either (99m)Tc sestamibi (n = 915) or (99m)Tc tetrofosmin (n = 903) and cardiac catheterization. A clinical index was generated and consisted of clinical and demographic variables. Information concerning death, cardiovascular death, and nonfatal myocardial infarction was 93% complete during the 1.5-year study period. Cox proportional hazards models were generated to help determine the incremental contribution of SPECT sum stress score (SSS) and the imaging agent variable to the clinical index. RESULTS Exercise was used for stress testing in 473 (52%) patients who received (99m)Tc tetrofosmin and 519 (57%) patients who received (99m)Tc sestamibi (P =.06). Cardiovascular death or myocardial infarction occurred in 130 patients. Resulting P values for chi(2) differences between models for the end points of (a) death from any cause, (b) cardiovascular death, and (c) cardiovascular death or myocardial infarction showed that SSS combined with clinical index was a significantly better model than adjusting for only baseline characteristics (P =.001, P <.001, P =.004, respectively). Incremental addition of either (99m)Tc tetrofosmin or (99m)Tc sestamibi to those models containing SSS and the clinical index did not show further significant improvement (P =.87, P =.88, and P =.26 for death from any cause, cardiovascular death, and cardiovascular death or myocardial infarction, respectively). CONCLUSION This study shows that the type of clinically available (99m)Tc-labeled myocardial perfusion agents should not affect interpretation of results for risk stratification and prognostic assessment.
Collapse
Affiliation(s)
- Salvador Borges-Neto
- Department of Medicine, Duke Clinical Research Institute and Drexel School of Medicine, Duke University Medical Center, PO Box 3949, Durham, NC 27710, USA.
| | | | | | | | | | | | | |
Collapse
|
24
|
Groutars RGEJ, Verzijlbergen JF, Tiel-van Buul MMC, Zwinderman AH, Ascoop CAPL, van Hemel NM, van der Wall EE. The accuracy of 1-day dual-isotope myocardial SPECT in a population with high prevalence of coronary artery disease. Int J Cardiovasc Imaging 2003; 19:229-38. [PMID: 12834160 DOI: 10.1023/a:1023637804898] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND In order to evaluate the diagnostic efficacy of the 1-day separate acquisition dual-isotope single-photon emission computed tomography (SPECT) protocol, using 201Tl for the rest and 99mTc-tetrofosmin for the stress images, a consecutive series of patients with suspected or known coronary artery disease (CAD) was studied that also underwent coronary angiography. METHODS The results of myocardial SPECT, using a semi-quantitative visual analysis, were acquired in 123 patients and compared with the results of coronary angiography. Sensitivity and specificity were calculated, using thresholds of > or = 50 and > or = 70% stenosis. As an alternative for specificity, the normalcy rate was determined in a separate group of 87 patients with a < 5% pre-test likelihood of CAD. RESULTS The prevalence of CAD using > or =50 and > or = 70% stenosis was 88 and 78%, respectively. The sensitivity for detection of patients with > or = 50 and > or = 70% stenosis was 94 and 97%, respectively while specificity was 62 and 59%, respectively. The high rate of false positive perfusion defects resulting in a low specificity could be explained by specific clinical issues. However, the routine assessment with additional clinical and electrocardiographic data resulted in a correct interpretation of most of the false positive perfusion defects. The positive predictive value was 92 and 85% and the negative predictive value 46 and 77%, using thresholds of > or = 50 and > or = 70% stenosis, respectively. The normalcy rate was 91%. CONCLUSION The one-day separate acquisition rest 201Tl/stress 99mTc-tetrofosmin SPECT protocol is an efficient procedure for myocardial perfusion scintigraphy with high sensitivity for detection of CAD. Specific clinical issues caused a low value for specificity. Therefore, clinical information and knowledge of the electrocardiogram is essential for a correct interpretation of SPECT images.
Collapse
|
25
|
Papaioannou GI, Heller GV. Risk assessment by myocardial perfusion imaging for coronary revascularization, medical therapy, and noncardiac surgery. Cardiol Rev 2003; 11:60-72. [PMID: 12620131 DOI: 10.1097/01.crd.0000052100.88341.f9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Stress myocardial perfusion imaging (MPI) has become an important tool in risk stratification of patients with known coronary artery disease. A normal myocardial perfusion scan has a high negative predictive value and is associated with low annual mortality rate (< 1%). Patients with extensive ischemia (> 20% of the left ventricle), defects in more than 1 coronary vascular territory, transient or persistent left ventricular cavity dilation, and ejection fraction less than 45% have a high annual mortality rate (> 3%). Those patients should undergo coronary revascularization whenever feasible, as the cardiac event rate increases in proportion to the magnitude of the jeopardized myocardium. Stress MPI can be used to demonstrate ischemia in patients with symptoms early after coronary artery bypass surgery (< 5 years) or in those without symptoms late (>/= 5 years) after coronary artery bypass surgery. With respect to patients who underwent percutaneous interventions, stress MPI can help detect in-stent restenosis early after the intervention (3-6 months) or assess the progression of native coronary disease afterward. Since preliminary data suggest that a reduction in the perfusion defect size may translate to a reduction of coronary events, stress MPI can help assess the efficacy of medical management of coronary disease. Finally, stress MPI is indicated for perioperative cardiac risk stratification for noncardiac surgery in patients with intermediate risk predictors (mild angina, prior myocardial infarction or heart failure symptoms, diabetes mellitus, renal insufficiency) and poor functional capacity or in those who undergo high-risk surgery with significant implications in further preoperative management.
Collapse
Affiliation(s)
- Georgios I Papaioannou
- Cardiovascular Fellow, Nuclear Cardiology Laboratory, Hartford Hospital, University of Connecticut Medical Center, Hartford, Connecticut 06102, USA
| | | |
Collapse
|
26
|
Acampa W, Petretta M, Florimonte L, Mattera A, Cuocolo A. Prognostic value of exercise cardiac tomography performed late after percutaneous coronary intervention in symptomatic and symptom-free patients. Am J Cardiol 2003; 91:259-63. [PMID: 12565079 DOI: 10.1016/s0002-9149(02)03151-x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The long-term prognostic value of single-photon emission computed tomography (SPECT) performed late after percutaneous coronary intervention (PCI) has not been extensively evaluated. Moreover, the role of myocardial ischemia at SPECT in symptom-free patients after PCI is not clear. This study was designed to determine the long-term prognostic value of SPECT in predicting cardiac events after PCI in symptomatic and symptom-free patients. Exercise technetium-99m sestamibi SPECT was performed in 206 patients between 12 and 18 months after PCI. All patients were followed for a mean period of 37 +/- 16 months. Cardiac death, nonfatal myocardial infarction, and late revascularization procedures were considered to be events. Myocardial ischemia at SPECT was detectable in 44 patients. During follow-up, 24 patients experienced events (cardiac death in 4 patients, myocardial infarction in 10, and late revascularization in 10). At univariate analysis, the summed stress score (p <0.05) and summed difference score (p <0.001) were significant predictors of cardiac events. Event-free survival curves showed a higher event rate in patients with than without ischemia (p <0.001). The occurrence of cardiac events was higher in the presence of ischemia at SPECT in symptomatic and symptom-free patients (both p <0.001). The results of this study demonstrate that the extent and severity of myocardial ischemia at exercise SPECT performed between 12 and 18 months after PCI predicts cardiac events during long-term follow-up in symptomatic and symptom-free patients.
Collapse
Affiliation(s)
- Wanda Acampa
- Department of Biomorphological and Functional Sciences, Institute of Biostructures and Bioimaging of the National Council of Research, Naples, Italy
| | | | | | | | | |
Collapse
|
27
|
Ravizzini GC, Hanson MW, Shaw LK, Wong TZ, Hagge RJ, Pagnanelli RA, Jain D, Lima HS, Coleman RE, Borges-Neto S. Efficiency comparison between 99m Tc-tetrofosmin and 99m Tc-sestamibi myocardial perfusion studies. Nucl Med Commun 2002; 23:203-8. [PMID: 11891477 DOI: 10.1097/00006231-200203000-00002] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The purpose of this investigation was to compare the efficiency of two different imaging protocols using two different clinically available 99mTc labelled myocardial perfusion tracers. One thousand one hundred and thirty-four imaging studies were performed prospectively, using either 99mTc-tetrofosmin or 99mTc-sestamibi, alternating the use of each tracer for a total period of 8 months. 99mTc-tetrofosmin rest studies were performed with injections of 259MBq-370MBq and imaging 30 min later. Exercise studies were performed with injections of 777MBq-1.11GBq and imaging 20 min later. 99mTc-sestamibi studies used doses similar to those in the 99mTc-tetrofosmin studies. Imaging followed a standard procedure, at 60 min after rest injection, and 30 min after exercise. For patients undergoing pharmacological stress testing99mTc-sestamibi was imaged 45 min after injection and 99mTc-tetrofosmin was imaged 30 min after injection. Variables analysed were (1) injection-to-imaging time for the procedure, and (2) the number of repeated scans because of extra cardiac activity. The completion time for the rest study was significantly shorter for 99mTc-tetrofosmin compared to 99mTc-sestamibi (47.7+/-21.7 min vs 74.3+/-25.8 min P<0.0001). Likewise, the total study time was shorter for 99mTc-tetrofosmin compared to 99mTc-sestamibi (90+/-32.7 min vs 124+/-37 min, P<0.0001). More importantly, the number of repeated scans was higher with 99mTc-sestamibi compared to 99mTc-tetrofosmin, 21.4% vs 10%, P=0.001 for rest studies and 16.4% vs 7.9% P=0.001 [corrected] for rest and stress. It was concluded that, using a same day rest/stress protocol, 99mTc-tetrofosmin provided higher patient throughput with fewer repeat scans. These factors may be considered for efficiency improvement in nuclear cardiology laboratories using 99mTc perfusion tracers.
Collapse
Affiliation(s)
- G C Ravizzini
- Dept of Radiology (Nuclear Medicine), Duke University Medical Center, Durham, NC 27710, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Abstract
This article focuses on the following areas of myocardial perfusion imaging: radiotracer and protocol options, pharmacologic stress agents, and protocols and functional assessment with ECG-gated single photon emission CT.
Collapse
Affiliation(s)
- M D Cerqueira
- Department of Medicine, Georgetown University Hospital, Washington, DC 20007, USA.
| | | |
Collapse
|
29
|
Ballinger JR. 99m
Tc‐Tetrofosmin for Functional Imaging of P‐glycoprotein Modulation In Vivo. J Clin Pharmacol 2001. [DOI: 10.1177/0091270001417007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
30
|
Elhendy A, van Domburg RT, Sozzi FB, Poldermans D, Bax JJ, Roelandt JR. Impact of hypertension on the accuracy of exercise stress myocardial perfusion imaging for the diagnosis of coronary artery disease. BRITISH HEART JOURNAL 2001; 85:655-61. [PMID: 11359747 PMCID: PMC1729751 DOI: 10.1136/heart.85.6.655] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
AIM To compare the accuracy of exercise stress myocardial perfusion single photon emission computed tomography (SPECT) imaging for the diagnosis of coronary artery disease in patients with and without hypertension. METHODS A symptom limited bicycle exercise stress test in conjunction with 99m technetium sestamibi or tetrofosmin SPECT imaging was performed in 332 patients (mean (SD) age, 57 (10) years; 257 men, 75 women) without previous myocardial infarction who underwent coronary angiography. Of these, 137 (41%) had hypertension. Rest SPECT images were acquired 24 hours after the stress test. An abnormal scan was defined as one with reversible or fixed perfusion defects. RESULTS In hypertensive patients, myocardial perfusion abnormalities were detected in 79 of 102 patients with significant coronary artery disease and in nine of 35 patients without. In normotensive patients, myocardial perfusion abnormalities were detected in 104 of 138 patients with significant coronary artery disease and in 16 of 57 patients without. There were no differences between normotensive and hypertensive patients in sensitivity (77% (95% confidence interval (CI) 69% to 86%) v 75% (95% CI 68% to 83%)), specificity (74% (95% CI 60% to 89%) v 72% (95% CI 60% to 84%)), and accuracy (77% (95% CI 70% to 84%) v 74% (95% CI 68% to 80%)) of exercise SPECT for diagnosing coronary artery disease. The accuracy of SPECT was greater than electrocardiography, both in hypertensive patients (p = 0.005) and in normotensive patients (p = 0.0001). For the detection of coronary artery disease in individual vessels, sensitivity was 58% (95% CI 51% to 65%) v 57% (95% CI 51% to 64%), specificity was 86% (95% CI 82% to 90%) v 85% (95% CI 81% to 89%), and accuracy was 74% (95% CI 70% to 78%) v 74% (95% CI 70% to 78%) in patients with and without hypertension (NS). CONCLUSIONS In the usual clinical setting, the value of exercise myocardial perfusion scintigraphy for diagnosing coronary artery disease is not degraded by the presence of hypertension.
Collapse
Affiliation(s)
- A Elhendy
- Mayo Clinic, Plummer Building A1, 200 1st Street SW, Rochester, Minnesota 55905, USA.
| | | | | | | | | | | |
Collapse
|
31
|
Bavelaar-Croon CD, Pauwels EK, van der Wall EE. Gated single-photon emission computed tomographic myocardial imaging: a new tool in clinical cardiology. Am Heart J 2001; 141:383-90. [PMID: 11231435 DOI: 10.1067/mhj.2001.112780] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND Gated single-photon emission computed tomography (gated SPECT) myocardial perfusion imaging allows the analysis of left ventricular (LV) perfusion and function during the same acquisition. RESULTS Gated SPECT provides additional information to myocardial perfusion, which improves test specificity in patients with known or suspected coronary artery disease and hence diminishes the amount of borderline diagnosis. Because gated SPECT provides reliable information on LV ejection fraction and LV volumes, it is also a valuable tool in risk stratification. In addition, from gated SPECT, images can be reconstructed from which wall motion can be assessed showing a good correlation with wall motion assessed by accepted imaging modalities as echocardiography, magnetic resonance imaging, and contrast angiography. In the future wall motion analysis from gated SPECT may also be used for revascularization stratification. CONCLUSIONS Gated SPECT gives important additional information beyond myocardial perfusion imaging alone, which could have major clinical implications for optimal patient management.
Collapse
Affiliation(s)
- C D Bavelaar-Croon
- Division of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 AZ, Leiden, The Netherlands
| | | | | |
Collapse
|
32
|
Soman P, Taillefer R, DePuey EG, Udelson JE, Lahiri A. Enhanced detection of reversible perfusion defects by Tc-99m sestamibi compared to Tc-99m tetrofosmin during vasodilator stress SPECT imaging in mild-to-moderate coronary artery disease. J Am Coll Cardiol 2001; 37:458-62. [PMID: 11216963 DOI: 10.1016/s0735-1097(00)01148-7] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVES We prospectively compared dipyridamole single-photon emission computed tomography (SPECT) imaging with Tc-99m sestamibi and Tc-99m tetrofosmin for the detection of reversible perfusion defects in patients with mild-to-moderate coronary artery disease. BACKGROUND Tc-99m tetrofosmin has a lower first-pass myocardial extraction fraction compared to Tc-99m sestamibi and thus could underestimate mild perfusion defects. METHODS Eighty-one patients with 50% to 90% stenosis in one or two major epicardial vessels without previous myocardial infarction, and seven with <5% probability of coronary artery disease underwent dipyridamole SPECT imaging with both agents. The SPECT data were analyzed quantitatively. RESULTS Tc-99m sestamibi detected reversible perfusion defects in a greater number of segments (total 363 and 285, p < 0.001, and mean +/- SD, 2.2 +/- 3.0 and 1.8 +/- 2.5 per patient, p = 0.008, for Tc-99m sestamibi and Tc-99m tetrofosmin, respectively), demonstrated a larger extent of perfusion defect (mean +/- SD, 15.8% +/- 12.3% and 12.0% +/- 11.4%, p < 0.03, for Tc-99m sestamibi and Tc-99m tetrofosmin, respectively) and more often correctly identified patients with disease in more than one coronary artery (p = 0.02). There was better defect contrast with Tc-99m sestamibi (defect/normal wall count ratios were 0.60 +/- 0.15 vs. 0.73 +/- 0.14 for Tc-99m sestamibi and Tc99m tetrofosmin, respectively, p = 0.01, for reversible defects seen in identical segments with both agents; and 0.73 +/- 0.16 vs 0.79 +/- 0.17, respectively, p <0.01, for reversible defects detected with either agent alone). There was no significant difference in diagnostic sensitivity or image quality. CONCLUSIONS These differences between two commonly used tracers may have significant diagnostic and prognostic implications.
Collapse
Affiliation(s)
- P Soman
- Department of Cardiovascular Medicine, Northwick Park & St. Marks Hospitals, NHS Trust and Institute of Medical Research, Harrow, United Kingdom
| | | | | | | | | |
Collapse
|
33
|
Bavelaar-Croon CD, Atsma DE, van der Wall EE, Dibbets-Schneider P, Zwinderman AH, Pauwels EK. The additive value of gated SPET myocardial perfusion imaging in patients with known and suspected coronary artery disease. Nucl Med Commun 2001; 22:45-55. [PMID: 11233551 DOI: 10.1097/00006231-200101000-00007] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
In myocardial perfusion scintigraphy, the clinical significance of fixed defects presents some difficulty. In this study, we evaluated whether additional information on left ventricular function assessed by quantitative gated single-photon emission computed tomography (gated SPET) would increase the diagnostic yield of the study in such patients. We studied 55 patients with a previous myocardial infarction and 20 patients without a previous myocardial infarction using gated SPET 99Tc(m)-tetrofosmin myocardial perfusion imaging. Each patient had to have a persistent perfusion defect consisting of at least three contiguous segments in the same vascular territory. The left ventricle was divided into 20 segments which were analysed for perfusion and wall thickening on a 4-point severity scale. Of the 55 patients with myocardial infarction, 19 (35%) patients showed preserved wall thickening in the region of the previous infarction with fixed perfusion abnormalities, which suggested residual myocardial viability. In the 20 patients without myocardial infarction, preserved wall thickening was seen in 10 (50%) patients with fixed perfusion defects, suggesting an attenuation artefact. Conversely, in 16 (29%) patients in the myocardial infarction group and two (10%) patients in the non-myocardial infarction group normal perfusion was associated with severely diminished wall thickening possibly due to stunning. We found an excellent correlation between wall thickening and left ventricular ejection fraction both for the patients with myocardial infarction and the patients without myocardial infarction (r = 0.86 and r = 0.82, respectively, both P<0.0001). A reasonable correlation between perfusion and left ventricular ejection fraction was found for the patients with myocardial infarction (r = 0.41, P = 0.002), and a non-significant correlation for the patients without myocardial infarction (r = 0.37, P = 0.1). Quantitative gated SPET myocardial imaging allows the detection of residual wall thickening in patients with a previous myocardial infarction who show severe fixed perfusion defects. In patients without myocardial infarction, gated SPET imaging allows differentiation between an attenuation artefact and a fixed perfusion defect due to coronary artery disease. In addition, gated SPET may show diminished ventricular function in normally perfused segments possibly due to myocardial stunning. The addition of gated SPET myocardial perfusion imaging increases diagnostic confidence and may have direct clinical implications for optimal patient management.
Collapse
Affiliation(s)
- C D Bavelaar-Croon
- Department of Radiology, Leiden University Medical Center, The Netherlands.
| | | | | | | | | | | |
Collapse
|
34
|
Hurwitz GA, McLaughlin DS, Slomka PJ. Comparing the image quality of myocardial perfusion agents in the clinical laboratory: small test groups and large reference populations. Nucl Med Commun 2000; 21:907-15. [PMID: 11130331 DOI: 10.1097/00006231-200010000-00004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Myocardial perfusion studies have been performed for 6 years using technetium-99m (99Tcm)-sestamibi (MIBI). In this study we evaluated a newer agent, 99Tcm-tetrofosmin (TF), on a trial basis for 2 weeks, and compared the results from each week to those in an adjacent week of MIBI use. The routine protocol included weight-based dosing, frequent dipyridamole use, and separate-day rest and stress wherever possible. During the first week, TF was used with 'usual' image timing, i.e. stress tomography performed 30-60 min after stress, and ancillary immediate images performed 4 min after injection. For the second week, 'early' tomography was performed 15-30 min after stress. TF scans (n = 53) were compared with MIBI scans for the adjacent weeks (n = 54) and with a historical reference series (n = 1800). Blinded analysis was made of tomographic image quality, peak myocardial counts and background activity (lung and abdomen) on immediate and delayed acquisitions and on tomographic reconstructions. The TF and MIBI test groups were similar with respect to gender, weight, stress protocol, tracer doses, imaging times and scintigraphic findings. Using analysis of variance, the tomographic quality scores were similar for the two observers, with stress>rest (P<0.0001), 'usual'>'early' (P<0.001) and MIBI>TF (P<0.05). Myocardial counts were approximately 20% higher with the MIBI test group than with TF at all times after stress (P=0.001), and were similar to the reference population. MIBI with usual timing gave more favourable stress abdominal background ratios than the other three agent/timing combinations. Satisfactory images could be obtained with TF, but no apparent advantage over MIBI could be attained with earlier post-stress imaging. Subtle advantages for MIBI over TF were suggested by comparison of the small test groups. In our local imaging context, these conclusions were reinforced by a large control series.
Collapse
Affiliation(s)
- G A Hurwitz
- Department of Diagnostic Radiology/Nuclear Medicine, London Health Sciences Centre, Ontario, Canada.
| | | | | |
Collapse
|
35
|
Levine MG, Ahlberg AW, Mann A, White MP, McGill CC, Mendes de Leon C, Piriz JM, Waters D, Heller GV. Comparison of exercise, dipyridamole, adenosine, and dobutamine stress with the use of Tc-99m tetrofosmin tomographic imaging. J Nucl Cardiol 1999; 6:389-96. [PMID: 10461605 DOI: 10.1016/s1071-3581(99)90004-1] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
PURPOSE The purpose of this study was to compare defect extent and severity and myocardial uptake with exercise and pharmacologic stress with technetium-99m (Tc-99m) tetrofosmin tomographic myocardial perfusion imaging. BACKGROUND Detection of stress-induced myocardial perfusion defects depends on both a disparity in blood flow between normal and stenotic vessels and the extraction fraction and linearity of myocardial uptake of the tracer. There are limited clinical data for exercise or pharmacologic stress with Tc-99m tetrofosmin tomographic myocardial perfusion imaging. METHODS Thirty-one patients with coronary artery disease and 7 with a < 5% likelihood of coronary artery disease underwent on separate days Tc-99m tetrofosmin single-photon emission computed tomographic imaging at rest and after exercise, dipyridamole, adenosine, and dobutamine stress. Images were interpreted by a blinded consensus of 3 experienced readers with a 17-segment model and 5-point scoring system. RESULTS Compared with exercise, the summed stress score was smaller with dipyridamole (P < .01), and the reversibility score was smaller with both dipyridamole (P < .01) and dobutamine (P < .05), whereas the number of abnormal and reversible segments was less with both dipyridamole (P < .01 and P < .001, respectively) and dobutamine (both P < .05). No significant differences were found in the summed stress or reversibility scores and the number of abnormal or reversible segments between exercise and adenosine. CONCLUSIONS Compared with exercise, defect extent, severity, and reversibility are less with dipyridamole and dobutamine with Tc-99m tetrofosmin single photon emission computed tomographic imaging.
Collapse
Affiliation(s)
- M G Levine
- Nuclear Cardiology Laboratory, Hartford Hospital, Conn. 06102-5037, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Abstract
99mTc labeled myocardial perfusion tracers have significantly advanced the field of noninvasive diagnostic evaluation and risk stratification of patients with known or suspected coronary artery disease by providing comprehensive information about myocardial perfusion and function from a single study. Of various currently available invasive and noninvasive test modalities, myocardial perfusion imaging provides the most powerful prognostic information that is incremental to the information obtained from invasive evaluation. Future research should focus on the development of perfusion tracers that linearly track myocardial blood flow over a wide range and have minimal splanchnic uptake. Availability of an effective attenuation and scatter correction program would further eliminate some of the current limitations of this technique.
Collapse
Affiliation(s)
- D Jain
- Section of Cardiovascular Medicine, Yale University School of Medicine, New Haven, CT 06520, USA
| |
Collapse
|
37
|
Nicolai E, Cuocolo A, Acampa W, Varrone A, Pace L, Salvatore M. Exercise-test Tc-99m tetrofosmin SPECT in patients with chronic ischemic left ventricular dysfunction: direct comparison with Ti-201 reinjection. J Nucl Cardiol 1999; 6:270-7. [PMID: 10385182 DOI: 10.1016/s1071-3581(99)90038-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND This study was designed to compare the results of exercise-rest technetium-99m tetrofosmin single photon emission computed tomography (SPECT) with those of thallium-201 reinjection at rest after exercise-redistribution imaging in the same patients with chronic ischemic left ventricular (LV) dysfunction. METHODS Within 1 week, 33 patients with chronic myocardial infarction and LV dysfunction underwent exercise-rest tetrofosmin SPECT and Tl-201 reinjection at rest after exercise-redistribution imaging. In each patient, regional tetrofosmin and Tl-201 activity was quantitatively measured in 22 myocardial segments. Regional LV function was assessed in corresponding segments by echocardiography. RESULTS Agreement in the evaluation of regional perfusion status between tetrofosmin and Tl-201 imaging was observed in 78% of the 726 total segments, with a kappa value of 0.61. In segments with normal function at echocardiography (n = 436), no difference between Tl-201 and tetrofosmin uptake was observed. In hypokinetic segments (n = 138), exercise tetrofosmin uptake was lower (P < .01) as compared with exercise Tl-201 activity, whereas no difference was observed between tetrofosmin uptake at rest as compared with Tl-201 activity on redistribution and reinjection images. In segments with severe functional impairment (akinetic or dyskinetic, n = 152), tetrofosmin uptake on exercise images was reduced (P < .01) as compared with exercise Tl-201 activity; furthermore, tetrofosmin uptake at rest was lower (P < .01) as compared with Tl-201 activity on both redistribution and reinjection images. In these segments, concordance in the detection of myocardial viability between tetrofosmin and Tl-201 imaging was observed in 138 (91%) of the 152 segments, with a kappa value of 0.77. CONCLUSIONS In patients with chronic coronary artery disease and LV dysfunction quantitative exercise-rest tetrofosmin and Tl-201 reinjection SPECT provide similar information in the assessment of perfusion status and in the detection of myocardial viability.
Collapse
Affiliation(s)
- E Nicolai
- Nuclear Medicine Center of the National Council of Research (CNR), Department of Biomorphological and Functional Sciences, University Federico II, Napoli, Italy
| | | | | | | | | | | |
Collapse
|