1
|
Tuziuti T, Yasui K, Kanematsu W. Decrease in the Surface Tension of Nanobubble Dispersion in Water: Results of Surface Excess of Bulk Nanobubbles at Interfaces. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:5771-5778. [PMID: 37052932 DOI: 10.1021/acs.langmuir.3c00040] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
The effect of nanobubbles (NBs) on the surface tension of liquid was investigated by three methods of different measuring principles, pendant drop (PD), Wilhelmy, and du Noüy methods, over a wide range of number concentration of bulk NBs (BNBs). In all of the three methods, the surface tension decreased in proportion to the number concentration of BNBs and the proportional constant was different among the three methods. Such behavior was inferred to be caused by the surface excess of BNBs at the gas-liquid or solid-liquid interface. In the PD method, the hydrophobic interaction between BNBs and air around a drop seems to cause the surface excess of BNBs along the surface of water drops. It brings about a subtle change in its profile, resulting in the decrease in surface tension, which takes a time of hundreds of seconds. Meanwhile, in the Wilhelmy and du Noüy methods, electrostatic attractive force between BNBs and a plate or ring is a likely cause of surface excess at the solid-liquid interface, resulting in the instantaneous decrease in surface tension. This study also provides a practical methodology of comparison for surface tension of NB dispersion: surface tension shall be compared among different samples with the same measurement method. Especially in the PD method, retention time of droplets before measurement shall be the same among samples.
Collapse
Affiliation(s)
- Toru Tuziuti
- National Institute of Advanced Industrial Science and Technology (AIST), 4-205 Sakaurazaka, Moriyama-ku, Nagoya 463-8560, Japan
| | - Kyuichi Yasui
- National Institute of Advanced Industrial Science and Technology (AIST), 4-205 Sakaurazaka, Moriyama-ku, Nagoya 463-8560, Japan
| | - Wataru Kanematsu
- National Institute of Advanced Industrial Science and Technology (AIST), 4-205 Sakaurazaka, Moriyama-ku, Nagoya 463-8560, Japan
| |
Collapse
|
2
|
Altammar KA. A review on nanoparticles: characteristics, synthesis, applications, and challenges. Front Microbiol 2023; 14:1155622. [PMID: 37180257 PMCID: PMC10168541 DOI: 10.3389/fmicb.2023.1155622] [Citation(s) in RCA: 47] [Impact Index Per Article: 47.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 03/21/2023] [Indexed: 05/16/2023] Open
Abstract
The significance of nanoparticles (NPs) in technological advancements is due to their adaptable characteristics and enhanced performance over their parent material. They are frequently synthesized by reducing metal ions into uncharged nanoparticles using hazardous reducing agents. However, there have been several initiatives in recent years to create green technology that uses natural resources instead of dangerous chemicals to produce nanoparticles. In green synthesis, biological methods are used for the synthesis of NPs because biological methods are eco-friendly, clean, safe, cost-effective, uncomplicated, and highly productive. Numerous biological organisms, such as bacteria, actinomycetes, fungi, algae, yeast, and plants, are used for the green synthesis of NPs. Additionally, this paper will discuss nanoparticles, including their types, traits, synthesis methods, applications, and prospects.
Collapse
Affiliation(s)
- Khadijah A. Altammar
- Department of Biology, College of Science, University of Hafr Al Batin, Hafr Al-Batin, Saudi Arabia
| |
Collapse
|
3
|
Rhaman MM, Islam MR, Akash S, Mim M, Noor alam M, Nepovimova E, Valis M, Kuca K, Sharma R. Exploring the role of nanomedicines for the therapeutic approach of central nervous system dysfunction: At a glance. Front Cell Dev Biol 2022; 10:989471. [PMID: 36120565 PMCID: PMC9478743 DOI: 10.3389/fcell.2022.989471] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Accepted: 08/08/2022] [Indexed: 12/12/2022] Open
Abstract
In recent decades, research scientists, molecular biologists, and pharmacologists have placed a strong emphasis on cutting-edge nanostructured materials technologies to increase medicine delivery to the central nervous system (CNS). The application of nanoscience for the treatment of neurodegenerative diseases (NDs) such as Alzheimer’s disease (AD), Parkinson’s disease (PD), multiple sclerosis (MS), Huntington’s disease (HD), brain cancer, and hemorrhage has the potential to transform care. Multiple studies have indicated that nanomaterials can be used to successfully treat CNS disorders in the case of neurodegeneration. Nanomedicine development for the cure of degenerative and inflammatory diseases of the nervous system is critical. Nanoparticles may act as a drug transporter that can precisely target sick brain sub-regions, boosting therapy success. It is important to develop strategies that can penetrate the blood–brain barrier (BBB) and improve the effectiveness of medications. One of the probable tactics is the use of different nanoscale materials. These nano-based pharmaceuticals offer low toxicity, tailored delivery, high stability, and drug loading capacity. They may also increase therapeutic effectiveness. A few examples of the many different kinds and forms of nanomaterials that have been widely employed to treat neurological diseases include quantum dots, dendrimers, metallic nanoparticles, polymeric nanoparticles, carbon nanotubes, liposomes, and micelles. These unique qualities, including sensitivity, selectivity, and ability to traverse the BBB when employed in nano-sized particles, make these nanoparticles useful for imaging studies and treatment of NDs. Multifunctional nanoparticles carrying pharmacological medications serve two purposes: they improve medication distribution while also enabling cell dynamics imaging and pharmacokinetic study. However, because of the potential for wide-ranging clinical implications, safety concerns persist, limiting any potential for translation. The evidence for using nanotechnology to create drug delivery systems that could pass across the BBB and deliver therapeutic chemicals to CNS was examined in this study.
Collapse
Affiliation(s)
- Md. Mominur Rhaman
- Department of Pharmacy, Faculty of Allied Health Sciences, Daffodil International University, Dhaka, Bangladesh
- *Correspondence: Md. Mominur Rhaman, ; Rohit Sharma,
| | - Md. Rezaul Islam
- Department of Pharmacy, Faculty of Allied Health Sciences, Daffodil International University, Dhaka, Bangladesh
| | - Shopnil Akash
- Department of Pharmacy, Faculty of Allied Health Sciences, Daffodil International University, Dhaka, Bangladesh
| | - Mobasharah Mim
- Department of Pharmacy, Faculty of Allied Health Sciences, Daffodil International University, Dhaka, Bangladesh
| | - Md. Noor alam
- Department of Pharmacy, Faculty of Allied Health Sciences, Daffodil International University, Dhaka, Bangladesh
| | - Eugenie Nepovimova
- Department of Chemistry, Faculty of Science, University of Hradec Králové, Hradec Králové, Czech Republic
| | - Martin Valis
- Department of Neurology, Charles University in Prague, Faculty of Medicine in Hradec Králové and University Hospital, Hradec Králové, Czech Republic
| | - Kamil Kuca
- Department of Chemistry, Faculty of Science, University of Hradec Králové, Hradec Králové, Czech Republic
- Andalusian Research Institute in Data Science and Computational Intelligence (DaSCI), University of Granada, Granada, Spain
| | - Rohit Sharma
- Department of Rasa Shastra and Bhaishajya Kalpana, Faculty of Ayurveda, Institute of Medical Sciences, Banaras Hindu University, Varanasi, India
- *Correspondence: Md. Mominur Rhaman, ; Rohit Sharma,
| |
Collapse
|
4
|
Jiang C, Liu S, Zhang T, Liu Q, Alvarez PJJ, Chen W. Current Methods and Prospects for Analysis and Characterization of Nanomaterials in the Environment. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:7426-7447. [PMID: 35584364 DOI: 10.1021/acs.est.1c08011] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Analysis and characterization of naturally occurring and engineered nanomaterials in the environment are critical for understanding their environmental behaviors and defining real exposure scenarios for environmental risk assessment. However, this is challenging primarily due to the low concentration, structural heterogeneity, and dynamic transformation of nanomaterials in complex environmental matrices. In this critical review, we first summarize sample pretreatment methods developed for separation and preconcentration of nanomaterials from environmental samples, including natural waters, wastewater, soils, sediments, and biological media. Then, we review the state-of-the-art microscopic, spectroscopic, mass spectrometric, electrochemical, and size-fractionation methods for determination of mass and number abundance, as well as the morphological, compositional, and structural properties of nanomaterials, with discussion on their advantages and limitations. Despite recent advances in detecting and characterizing nanomaterials in the environment, challenges remain to improve the analytical sensitivity and resolution and to expand the method applications. It is important to develop methods for simultaneous determination of multifaceted nanomaterial properties for in situ analysis and characterization of nanomaterials under dynamic environmental conditions and for detection of nanoscale contaminants of emerging concern (e.g., nanoplastics and biological nanoparticles), which will greatly facilitate the standardization of nanomaterial analysis and characterization methods for environmental samples.
Collapse
Affiliation(s)
- Chuanjia Jiang
- College of Environmental Science and Engineering, Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, Nankai University, 38 Tongyan Rd., Tianjin 300350, China
| | - Songlin Liu
- College of Environmental Science and Engineering, Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, Nankai University, 38 Tongyan Rd., Tianjin 300350, China
| | - Tong Zhang
- College of Environmental Science and Engineering, Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, Nankai University, 38 Tongyan Rd., Tianjin 300350, China
| | - Qian Liu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Pedro J J Alvarez
- Department of Civil and Environmental Engineering, Rice University, 6100 Main Street, Houston, Texas 77005, United States
| | - Wei Chen
- College of Environmental Science and Engineering, Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, Nankai University, 38 Tongyan Rd., Tianjin 300350, China
| |
Collapse
|
5
|
Babu KS, Amamcharla JK. Generation methods, stability, detection techniques, and applications of bulk nanobubbles in agro-food industries: a review and future perspective. Crit Rev Food Sci Nutr 2022; 63:9262-9281. [PMID: 35467989 DOI: 10.1080/10408398.2022.2067119] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Nanobubble (NB) technologies have received considerable attention for various applications due to their low cost, eco-friendliness, scale-up potential, process control, and unique physical characteristics. NB stands for nanoscopic gaseous cavities, typically <1 μm in diameter. NBs can exist on surfaces (surface or interfacial NBs) and be dispersed in a bulk liquid phase (bulk NBs). Compared to the microbubbles, NBs exhibit high specific surface area, negative surface charge, and better adsorption. Bulk NBs can be generated by hydrodynamic/acoustic cavitation, electrolysis, water-solvent mixing, nano-membrane filtration, and so on. NBs exhibit extraordinary longevity compared to microbubbles, prompting the interest of the scientific community aiming for potential applications including medicine, agriculture, food, wastewater treatment, surface cleaning, and so on. Based on the limited amount of research work available regarding the influence of NBs on food matrices, further research, however, needs to be done to provide more insights into its applications in food industries. This review provides an overview of the generation methods for NBs, techniques to evaluate them, and a discussion of their stability and several applications in various fields of science were discussed. However, recent studies have revealed that, despite the many benefits of NB technologies, several NB generating approaches are still limited in their application in specific agro-food industries. Further study should focus on process optimization, integrating various NB generation techniques/combining with other emerging technologies in order to achieve rapid technical progress and industrialization of NB-based technologies.HighlightsNanobubbles (NBs) are stable spherical entities of gas within liquid and are operationally defined as having diameters less than 1 µm.Currently, various reported theories still lack the ability to explain the evidence and stability of NBs in water, numerous NB applications have emerged due to the unique properties of NBs.NB technologies can be applied to various food and dairy products (e.g. yogurt and ice cream) and other potential applications, including agriculture (e.g. seed germination and plant growth), wastewater treatment, surface cleaning, and so on.
Collapse
Affiliation(s)
- Karthik S Babu
- Department of Animal Sciences and Industry/Food Science Institute, Kansas State University, Manhattan, Kansas, USA
| | - Jayendra K Amamcharla
- Department of Animal Sciences and Industry/Food Science Institute, Kansas State University, Manhattan, Kansas, USA
| |
Collapse
|
6
|
Quattrini F, Berrecoso G, Crecente-Campo J, Alonso MJ. Asymmetric flow field-flow fractionation as a multifunctional technique for the characterization of polymeric nanocarriers. Drug Deliv Transl Res 2021; 11:373-395. [PMID: 33521866 PMCID: PMC7987708 DOI: 10.1007/s13346-021-00918-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/19/2021] [Indexed: 12/28/2022]
Abstract
The importance of polymeric nanocarriers in the field of drug delivery is ever-increasing, and the accurate characterization of their properties is paramount to understand and predict their behavior. Asymmetric flow field-flow fractionation (AF4) is a fractionation technique that has gained considerable attention for its gentle separation conditions, broad working range, and versatility. AF4 can be hyphenated to a plurality of concentration and size detectors, thus permitting the analysis of the multifunctionality of nanomaterials. Despite this potential, the practical information that can be retrieved by AF4 and its possible applications are still rather unfamiliar to the pharmaceutical scientist. This review was conceived as a primer that clearly states the "do's and don'ts" about AF4 applied to the characterization of polymeric nanocarriers. Aside from size characterization, AF4 can be beneficial during formulation optimization, for drug loading and drug release determination and for the study of interactions among biomaterials. It will focus mainly on the advances made in the last 5 years, as well as indicating the problematics on the consensus, which have not been reached yet. Methodological recommendations for several case studies will be also included.
Collapse
Affiliation(s)
- Federico Quattrini
- Center for Research in Molecular Medicine and Chronic Diseases, Singular Research Centers, 15782, Santiago de Compostela, Spain
| | - Germán Berrecoso
- Center for Research in Molecular Medicine and Chronic Diseases, Singular Research Centers, 15782, Santiago de Compostela, Spain
- Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), IDIS Research Institute, 15706, Santiago de Compostela, Spain
- Department of Pharmacy and Pharmaceutical Technology, School of Pharmacy, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain
| | - José Crecente-Campo
- Center for Research in Molecular Medicine and Chronic Diseases, Singular Research Centers, 15782, Santiago de Compostela, Spain.
- Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), IDIS Research Institute, 15706, Santiago de Compostela, Spain.
- Department of Pharmacy and Pharmaceutical Technology, School of Pharmacy, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain.
| | - María José Alonso
- Center for Research in Molecular Medicine and Chronic Diseases, Singular Research Centers, 15782, Santiago de Compostela, Spain.
- Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), IDIS Research Institute, 15706, Santiago de Compostela, Spain.
- Department of Pharmacy and Pharmaceutical Technology, School of Pharmacy, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain.
| |
Collapse
|
7
|
Kanematsu W, Tuziuti T, Yasui K. The influence of storage conditions and container materials on the long term stability of bulk nanobubbles — Consideration from a perspective of interactions between bubbles and surroundings. Chem Eng Sci 2020. [DOI: 10.1016/j.ces.2020.115594] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
8
|
Rabies Vaccine Characterization by Nanoparticle Tracking Analysis. Sci Rep 2020; 10:8149. [PMID: 32424186 PMCID: PMC7235079 DOI: 10.1038/s41598-020-64572-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 04/20/2020] [Indexed: 11/09/2022] Open
Abstract
There are concerns that effectiveness and consistency of biopharmaceutical formulations, including vaccines, may be compromised by differences in size, concentration and shape of particles in suspension. Thus, a simple method that can help monitor and characterize these features is needed. Here, nanoparticle tracking analysis (NTA) was used to characterize particle concentration and size distribution of a highly-purified rabies vaccine (RABV), produced in Vero cells without raw materials of animal origin (RMAO). The NTA technique was qualified for characterization of RABV particles by assessing the stability profile of vaccine particles over 5-55 °C. Antigenicity of the viral particle was also monitored with the enzyme-linked immunosorbent assay (ELISA) and NTA. RABV particle size diameters were 100-250 nm (mean:150 nm), similar to sizes obtained when labelled with rabies anti-G D1-25 monoclonal antibody, suggesting mainly antigenic virus-like particles, also confirmed by transmission electron microscopy. Thermal stress at 55 °C decreased the concentration of anti-G D1-25-labelled particles from 144 hours, coherent with conformational changes leading to loss of G protein antigenicity without impacting aggregation. Results from RABV antigenicity assessment during the 24 months monitoring of stability showed good correlation between NTA and ELISA. NTA is a suitable approach for the characterization of biopharmaceutical suspensions.
Collapse
|
9
|
Poon C, Patel AA. Organic and inorganic nanoparticle vaccines for prevention of infectious diseases. NANO EXPRESS 2020. [DOI: 10.1088/2632-959x/ab8075] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
10
|
Nanoparticle Tracking Analysis to Examine the Temperature-Induced Aggregation of Proteins. Methods Mol Biol 2019. [PMID: 31342424 DOI: 10.1007/978-1-4939-9678-0_10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
In recent years, nanoparticle tracking analysis (NTA) has emerged as an alternative tool for particle size characterization. Especially when examining polydisperse systems, individual particle to particle tracking allows for higher peak resolution than dynamic light scattering techniques. However, NTA requires an experienced user with a good insight into how the different settings can affect the determination of particle size and size distributions. This chapter provides a guideline for protein aggregation studies using the example of temperature-induced aggregation of IgG at low concentration.
Collapse
|
11
|
Ermert D, Laabei M, Weckel A, Mörgelin M, Lundqvist M, Björck L, Ram S, Linse S, Blom AM. The Molecular Basis of Human IgG-Mediated Enhancement of C4b-Binding Protein Recruitment to Group A Streptococcus. Front Immunol 2019; 10:1230. [PMID: 31214187 PMCID: PMC6557989 DOI: 10.3389/fimmu.2019.01230] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 05/14/2019] [Indexed: 11/25/2022] Open
Abstract
Streptococcus pyogenes infects over 700 million people worldwide annually. Immune evasion strategies employed by the bacteria include binding of the complement inhibitors, C4b-binding protein (C4BP) and Factor H in a human-specific manner. We recently showed that human IgG increased C4BP binding to the bacterial surface, which promoted streptococcal immune evasion and increased mortality in mice. We sought to identify how IgG promotes C4BP binding to Protein H, a member of the M protein family. Dimerization of Protein H is pivotal for enhanced binding to human C4BP. First, we illustrated that Protein H, IgG, and C4BP formed a tripartite complex. Second, surface plasmon resonance revealed that Protein H binds IgG solely through Fc, but not Fab domains, and with high affinity (IgG-Protein H: KD = 0.4 nM; IgG-Fc-Protein H: KD ≤ 1.6 nM). Each IgG binds two Protein H molecules, while up to six molecules of Protein H bind one C4BP molecule. Third, interrupting Protein H dimerization either by raising temperature to 41°C or with a synthetic peptide prevented IgG-Protein H interactions. IgG-Fc fragments or monoclonal human IgG permitted maximal C4BP binding when used at concentrations from 0.1 to 10 mg/ml. In contrast, pooled human IgG enhanced C4BP binding at concentrations up to 1 mg/ml; decreased C4BP binding at 10 mg/ml occurred probably because of Fab-streptococcal interactions at these high IgG concentrations. Taken together, our data show how S. pyogenes exploits human IgG to evade complement and enhance its virulence. Elucidation of this mechanism could aid design of new therapeutics against S. pyogenes.
Collapse
Affiliation(s)
- David Ermert
- Division of Medical Protein Chemistry, Department of Translational Medicine, Lund University, Malmö, Sweden.,Division of Infectious Diseases and Immunology, Department of Medicine, University of Massachusetts Medical School, Worcester, MA, United States
| | - Maisem Laabei
- Division of Medical Protein Chemistry, Department of Translational Medicine, Lund University, Malmö, Sweden
| | - Antonin Weckel
- Division of Medical Protein Chemistry, Department of Translational Medicine, Lund University, Malmö, Sweden
| | | | - Martin Lundqvist
- Department of Biochemistry and Structural Biology, Center for Molecular Protein Science, Lund University, Lund, Sweden
| | - Lars Björck
- Division of Infection Medicine, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Sanjay Ram
- Division of Infectious Diseases and Immunology, Department of Medicine, University of Massachusetts Medical School, Worcester, MA, United States
| | - Sara Linse
- Department of Biochemistry and Structural Biology, Center for Molecular Protein Science, Lund University, Lund, Sweden
| | - Anna M Blom
- Division of Medical Protein Chemistry, Department of Translational Medicine, Lund University, Malmö, Sweden
| |
Collapse
|
12
|
Biophysical virus particle specific characterization to sharpen the definition of virus stability. Eur J Pharm Biopharm 2018; 132:62-69. [PMID: 30118752 DOI: 10.1016/j.ejpb.2018.08.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Revised: 08/10/2018] [Accepted: 08/13/2018] [Indexed: 12/31/2022]
Abstract
Vaccine thermostability is key to successful global immunization programs as it may have a significant impact on the continuous cold-chain maintenance logistics, as well as affect vaccine potency. Modern biological and biophysical techniques were combined to in-depth characterize the thermostability of a formulated rabies virus (RABV) in terms of antigenic and genomic titer, virus particle count and aggregation state. Tunable resistive pulse sensing (TRPS) and nanoparticle tracking analysis (NTA) were used to count virus particles while simultaneously determining their size distribution. RABV antigenicity was assessed by NTA using a monoclonal antibody that recognize a rabies glycoprotein (G protein) conformational epitope, enabling to specifically count antigenic rabies viruses. Agreement between antigenicity results from NTA and conventional method, as ELISA, was demonstrated. Additionally, NTA and ELISA showed mirrored loss of RABV antigenicity during forced degradation studies performed between 5 °C and 45 °C temperature exposure for one month. Concomitant with decreased antigenicity, emergence of RABV particle populations larger than those expected for rabies family viruses was observed, suggesting RABV aggregation induced by thermal stress. Finally, using a kinetic-based modeling approach to explore forced degradation antigenicity data (NTA, ELISA), a two-step model accurately describing antigenicity loss was identified. This model predicted a RABV shelf-life of more than 3 years at 5 °C; significant loss of antigenicity was predicted for samples maintained several months at ambient temperature. This thorough characterization of RABV forced degradation study originally provided a time-temperature mapping of RABV stability.
Collapse
|
13
|
Kestens V, Coleman VA, De Temmerman PJ, Minelli C, Woehlecke H, Roebben G. Improved Metrological Traceability of Particle Size Values Measured with Line-Start Incremental Centrifugal Liquid Sedimentation. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2017; 33:8213-8224. [PMID: 28731349 DOI: 10.1021/acs.langmuir.7b01714] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Line-start incremental centrifugal liquid sedimentation (disc-CLS) is a powerful method to determine particle size based on the principles of Stokes' law. Because several of the input quantities of the Stokes equation cannot be easily determined for this case of a rotating disc, the disc-CLS approach relies on calibrating the sedimentation time scale with reference particles. To use these calibrant particles for establishing metrological traceability, they must fulfill the same requirements as those imposed on a certified reference material, i.e., their certified Stokes diameter and density value must come with a realistic measurement uncertainty and with a traceability statement. As is the case for several other techniques, the calibrants do not always come with uncertainties for the assigned modal diameter and effective particle density. The lack of such information and the absence of a traceability statement make it difficult for the end-user to estimate the uncertainty of the measurement results and to compare them with results obtained by others. We present the results of a collaborative study that aimed at demonstrating the traceability of particle size results obtained with disc-CLS. For this purpose, the particle size and effective particle density of polyvinyl chloride calibrants were measured using different validated methods, and measurement uncertainties were estimated according to the Guide to the Expression of Uncertainty in Measurement. The results indicate that the modal Stokes diameter and effective particle density that are assigned to the calibrants are accurate within 5% and 3.5%, respectively, and that they can be used to establish traceability of particle size results obtained with disc-CLS. This conclusion has a great impact on the traceability statement of certified particle size reference materials, for which the traceability is limited to the size and density values of the calibrant particles.
Collapse
Affiliation(s)
- Vikram Kestens
- Directorate-General Joint Research Centre, European Commission , 2440 Geel, Belgium
| | - Victoria A Coleman
- Nanometrology Section, National Measurement Institute Australia , 2070 West Lindfield, New South Wales, Australia
| | - Pieter-Jan De Temmerman
- Service Trace Elements and Nanomaterials, Veterinary and Agrochemical Research Centre (CODA-CERVA) , 1180 Brussels, Belgium
| | - Caterina Minelli
- Chemical, Medical and Environmental Science Division, National Physical Laboratory , Middlesex, TW11 0LW, United Kingdom
| | | | - Gert Roebben
- Directorate-General Joint Research Centre, European Commission , 2440 Geel, Belgium
| |
Collapse
|
14
|
Kestens V, Bozatzidis V, De Temmerman PJ, Ramaye Y, Roebben G. Validation of a particle tracking analysis method for the size determination of nano- and microparticles. JOURNAL OF NANOPARTICLE RESEARCH : AN INTERDISCIPLINARY FORUM FOR NANOSCALE SCIENCE AND TECHNOLOGY 2017; 19:271. [PMID: 28824287 PMCID: PMC5543194 DOI: 10.1007/s11051-017-3966-8] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Accepted: 07/13/2017] [Indexed: 05/13/2023]
Abstract
Particle tracking analysis (PTA) is an emerging technique suitable for size analysis of particles with external dimensions in the nano- and sub-micrometre scale range. Only limited attempts have so far been made to investigate and quantify the performance of the PTA method for particle size analysis. This article presents the results of a validation study during which selected colloidal silica and polystyrene latex reference materials with particle sizes in the range of 20 nm to 200 nm were analysed with NS500 and LM10-HSBF NanoSight instruments and video analysis software NTA 2.3 and NTA 3.0. Key performance characteristics such as working range, linearity, limit of detection, limit of quantification, sensitivity, robustness, precision and trueness were examined according to recommendations proposed by EURACHEM. A model for measurement uncertainty estimation following the principles described in ISO/IEC Guide 98-3 was used for quantifying random and systematic variations. For nominal 50 nm and 100 nm polystyrene and a nominal 80 nm silica reference materials, the relative expanded measurement uncertainties for the three measurands of interest, being the mode, median and arithmetic mean of the number-weighted particle size distribution, varied from about 10% to 12%. For the nominal 50 nm polystyrene material, the relative expanded uncertainty of the arithmetic mean of the particle size distributions increased up to 18% which was due to the presence of agglomerates. Data analysis was performed with software NTA 2.3 and NTA 3.0. The latter showed to be superior in terms of sensitivity and resolution.
Collapse
Affiliation(s)
- Vikram Kestens
- Joint Research Centre (JRC), Directorate Health, Consumers and Reference Materials, European Commission, Retieseweg 111, 2440 Geel, Belgium
| | - Vassili Bozatzidis
- Joint Research Centre (JRC), Directorate Health, Consumers and Reference Materials, European Commission, Retieseweg 111, 2440 Geel, Belgium
| | - Pieter-Jan De Temmerman
- Service Trace Elements and Nanomaterials, Veterinary and Agrochemical Research Centre (CODA-CERVA), Groeselenberg 99, 1180 Brussels, Belgium
| | - Yannic Ramaye
- Joint Research Centre (JRC), Directorate Health, Consumers and Reference Materials, European Commission, Retieseweg 111, 2440 Geel, Belgium
| | - Gert Roebben
- Joint Research Centre (JRC), Directorate Health, Consumers and Reference Materials, European Commission, Retieseweg 111, 2440 Geel, Belgium
| |
Collapse
|
15
|
Gross J, Sayle S, Karow AR, Bakowsky U, Garidel P. Nanoparticle tracking analysis of particle size and concentration detection in suspensions of polymer and protein samples: Influence of experimental and data evaluation parameters. Eur J Pharm Biopharm 2016; 104:30-41. [PMID: 27108267 DOI: 10.1016/j.ejpb.2016.04.013] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2015] [Revised: 04/16/2016] [Accepted: 04/18/2016] [Indexed: 10/21/2022]
Abstract
Nanoparticle Tracking Analysis (NTA) is an emerging technique for detecting simultaneously sub-micron particle size distributions and particle concentrations of a sample. This study deals with the performance evaluation for the detection and characterisation of various particles by NTA. Our investigation focusses on the NTA measurement parameter set-ups, as will be shown in this study, are very crucial parameters to correctly analyse and interpret the data. In order to achieve this, we used (i) polystyrene standard particles as well as (ii) protein particles. We show the highly precise and reproducible detection of particle size and concentration in monodisperse polystyrene particle systems, under specified and constant parameter settings. On the other hand, our results exemplify potential risks and errors while setting inadequate parameters with regards to the results and thus interpretation thereof. In particular changes of the parameters, camera level (CL) and detection threshold (DT), led to significant changes in the determined particle concentration. We propose defined and specified "optimal" camera levels for monodisperse particle suspension characterisations in the size range of 20-1000nm. We illustrate that the results of polydisperse polystyrene standard particle solution measurements, highly depend on the used parameter settings, which are rarely published with the data. Changes in these settings led to the "appearance" or "disappearance" of particle populations ("peaks") for polydisperse systems. Thus, a correct evaluation of the particle size populations in the sample becomes very challenging. For the use of NTA in biopharmaceutical analysis, proteinaceous samples were investigated. We analysed protein particle suspensions and compared unstressed and stressed (formation of aggregates) protein samples similar to polystyrene particle analysis. We also studied these samples in two different measuring modes (general capture mode and live monitoring mode) that the commercially available analysis software is offering. Our results stated the live monitoring mode as more suitable for protein samples, as the results were more reproducible and less operator-depending. In conclusion, NTA is a potential technique and unique in quantitative evaluation of particle suspensions in the subvisible size range, especially for monodisperse suspensions. We strongly urge on not underestimating the influence of the measuring parameters on the obtained results, which should be presented with the data in order to better judge and interpret the NTA results.
Collapse
Affiliation(s)
- Julia Gross
- Philipps - University Marburg, Institute of Pharmaceutical Technology and Biopharmacy, D-35032 Marburg, Germany
| | - Sabrina Sayle
- Boehringer Ingelheim Pharma GmbH & Co. KG, Biopharmaceuticals, Protein Science, D-88397 Biberach an der Riss, Germany
| | - Anne R Karow
- Boehringer Ingelheim Pharma GmbH & Co. KG, Biopharmaceuticals, Protein Science, D-88397 Biberach an der Riss, Germany
| | - Udo Bakowsky
- Philipps - University Marburg, Institute of Pharmaceutical Technology and Biopharmacy, D-35032 Marburg, Germany
| | - Patrick Garidel
- Boehringer Ingelheim Pharma GmbH & Co. KG, Biopharmaceuticals, Protein Science, D-88397 Biberach an der Riss, Germany.
| |
Collapse
|
16
|
Vasudev R, Mathew S, Afonina N. Characterization of Submicron (0.1–1 μm) Particles in Therapeutic Proteins by Nanoparticle Tracking Analysis. J Pharm Sci 2015; 104:1622-31. [DOI: 10.1002/jps.24411] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2014] [Revised: 01/15/2015] [Accepted: 02/02/2015] [Indexed: 01/10/2023]
|