Anguizola JA, Pfaunmiller EL, Milanuk ML, Hage DS. Peak decay analysis and biointeraction studies of immunoglobulin binding and dissociation on protein G affinity microcolumns. Methods 2018; 146:39-45. [PMID: 29608965 DOI: 10.1016/j.ymeth.2018.03.013] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 03/13/2018] [Accepted: 03/23/2018] [Indexed: 01/21/2023] Open
Abstract
Protein G can be a valuable binding agent for antibodies and immunoglobulins in methods such as immunosensors, chromatographic-based immunoassays, and immunoaffinity chromatography. This report used the method of peak decay analysis along with frontal analysis and zonal elution studies to characterize the binding, elution and regeneration properties of affinity microcolumns that contained immobilized protein G. Frontal analysis was employed with rabbit immunoglobulin G (IgG) to characterize the binding capacity of these affinity microcolumns. Zonal elution experiments looking at the retained peaks for small injections of labeled rabbit IgG were used to optimize the column regeneration conditions. Peak decay analysis was then used to look at the effects of flow rate and elution pH on the release of several types of IgG from the protein G microcolumns. This approach made it possible to obtain detailed information on the use and behavior of such columns, as could be used in future work to optimize the capture or analysis of IgG and antibodies by such devices. The same approach and tools that were used in this report could also be adapted for work with affinity columns that make use of other supports, binding agents or targets.
Collapse
Affiliation(s)
| | | | - Mitchell L Milanuk
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA
| |
Collapse
|
2
|
Li Z, Beeram SR, Bi C, Suresh D, Zheng X, Hage DS. High-Performance Affinity Chromatography: Applications in Drug-Protein Binding Studies and Personalized Medicine. ADVANCES IN PROTEIN CHEMISTRY AND STRUCTURAL BIOLOGY 2015; 102:1-39. [PMID: 26827600 DOI: 10.1016/bs.apcsb.2015.09.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The binding of drugs with proteins and other agents in serum is of interest in personalized medicine because this process can affect the dosage and action of drugs. The extent of this binding may also vary with a given disease state. These interactions may involve serum proteins, such as human serum albumin or α1-acid glycoprotein, or other agents, such as lipoproteins. High-performance affinity chromatography (HPAC) is a tool that has received increasing interest as a means for studying these interactions. This review discusses the general principles of HPAC and the various approaches that have been used in this technique to examine drug-protein binding and in work related to personalized medicine. These approaches include frontal analysis and zonal elution, as well as peak decay analysis, ultrafast affinity extraction, and chromatographic immunoassays. The operation of each method is described and examples of applications for these techniques are provided. The type of information that can be obtained by these methods is also discussed, as related to the analysis of drug-protein binding and the study of clinical or pharmaceutical samples.
Collapse
Affiliation(s)
- Zhao Li
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Sandya R Beeram
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Cong Bi
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - D Suresh
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Xiwei Zheng
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA.
| |
Collapse
|
3
|
Zheng X, Li Z, Beeram S, Podariu M, Matsuda R, Pfaunmiller EL, White CJ, Carter N, Hage DS. Analysis of biomolecular interactions using affinity microcolumns: a review. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 968:49-63. [PMID: 24572459 PMCID: PMC4112177 DOI: 10.1016/j.jchromb.2014.01.026] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Revised: 01/16/2014] [Accepted: 01/19/2014] [Indexed: 12/15/2022]
Abstract
Affinity chromatography has become an important tool for characterizing biomolecular interactions. The use of affinity microcolumns, which contain immobilized binding agents and have volumes in the mid-to-low microliter range, has received particular attention in recent years. Potential advantages of affinity microcolumns include the many analysis and detection formats that can be used with these columns, as well as the need for only small amounts of supports and immobilized binding agents. This review examines how affinity microcolumns have been used to examine biomolecular interactions. Both capillary-based microcolumns and short microcolumns are considered. The use of affinity microcolumns with zonal elution and frontal analysis methods are discussed. The techniques of peak decay analysis, ultrafast affinity extraction, split-peak analysis, and band-broadening studies are also explored. The principles of these methods are examined and various applications are provided to illustrate the use of these methods with affinity microcolumns. It is shown how these techniques can be utilized to provide information on the binding strength and kinetics of an interaction, as well as on the number and types of binding sites. It is further demonstrated how information on competition or displacement effects can be obtained by these methods.
Collapse
Affiliation(s)
- Xiwei Zheng
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Zhao Li
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Sandya Beeram
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Maria Podariu
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Ryan Matsuda
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Erika L Pfaunmiller
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Christopher J White
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - NaTasha Carter
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA.
| |
Collapse
|
4
|
Zheng X, Li Z, Podariu MI, Hage DS. Determination of rate constants and equilibrium constants for solution-phase drug-protein interactions by ultrafast affinity extraction. Anal Chem 2014; 86:6454-60. [PMID: 24911267 PMCID: PMC4082384 DOI: 10.1021/ac501031y] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A method was created on the basis of ultrafast affinity extraction to determine both the dissociation rate constants and equilibrium constants for drug-protein interactions in solution. Human serum albumin (HSA), an important binding agent for many drugs in blood, was used as both a model soluble protein and as an immobilized binding agent in affinity microcolumns for the analysis of free drug fractions. Several drugs were examined that are known to bind to HSA. Various conditions to optimize in the use of ultrafast affinity extraction for equilibrium and kinetic studies were considered, and several approaches for these measurements were examined. The dissociation rate constants obtained for soluble HSA with each drug gave good agreement with previous rate constants reported for the same drugs or other solutes with comparable affinities for HSA. The equilibrium constants that were determined also showed good agreement with the literature. The results demonstrated that ultrafast affinity extraction could be used as a rapid approach to provide information on both the kinetics and thermodynamics of a drug-protein interaction in solution. This approach could be extended to other systems and should be valuable for high-throughput drug screening or biointeraction studies.
Collapse
Affiliation(s)
- Xiwei Zheng
- Department of Chemistry, University of Nebraska , 704 Hamilton Hall, Lincoln, Nebraska 68588, United States
| | | | | | | |
Collapse
|
5
|
Pfaunmiller E, Moser AC, Hage DS. Biointeraction analysis of immobilized antibodies and related agents by high-performance immunoaffinity chromatography. Methods 2012; 56:130-5. [PMID: 21907805 PMCID: PMC3270122 DOI: 10.1016/j.ymeth.2011.08.016] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2011] [Revised: 08/22/2011] [Accepted: 08/24/2011] [Indexed: 11/25/2022] Open
Abstract
A method is described based on high-performance immunoaffinity chromatography for examining the interactions of immobilized antibodies or related binding agents with their targets. It is shown how this method can be used to obtain information on the binding, elution and regeneration kinetics of immobilized binding agents, such as those used with immunoaffinity supports. The theory behind this approach is briefly described and it is demonstrated how both the kinetic and thermodynamic properties of a biointeraction can be determined experimentally through this method. Several applications are used to illustrate this technique, including antibody-antigen interactions and the binding of aptamers with their targets in the presence of silica-based supports. The same approach can be adapted for use with other types of targets, binding agents and support materials.
Collapse
Affiliation(s)
| | - Annette C. Moser
- Chemistry Department, University of Nebraska-Kearney, Kearney, NE
| | - David S. Hage
- Chemistry Department, University of Nebraska-Lincoln, Lincoln, NE
| |
Collapse
|
6
|
Mallik R, Yoo MJ, Briscoe CJ, Hage DS. Analysis of drug-protein binding by ultrafast affinity chromatography using immobilized human serum albumin. J Chromatogr A 2010; 1217:2796-803. [PMID: 20227701 DOI: 10.1016/j.chroma.2010.02.026] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2009] [Revised: 02/08/2010] [Accepted: 02/16/2010] [Indexed: 11/30/2022]
Abstract
Human serum albumin (HSA) was explored for use as a stationary phase and ligand in affinity microcolumns for the ultrafast extraction of free drug fractions and the use of this information for the analysis of drug-protein binding. Warfarin, imipramine, and ibuprofen were used as model analytes in this study. It was found that greater than 95% extraction of all these drugs could be achieved in as little as 250 ms on HSA microcolumns. The retained drug fraction was then eluted from the same column under isocratic conditions, giving elution in less than 40 s when working at 4.5 mL/min. The chromatographic behavior of this system gave a good fit with that predicted by computer simulations based on a reversible, saturable model for the binding of an injected drug with immobilized HSA. The free fractions measured by this method were found to be comparable to those determined by ultrafiltration, and equilibrium constants estimated by this approach gave good agreement with literature values. Advantages of this method include its speed and the relatively low cost of microcolumns that contain HSA. The ability of HSA to bind many types of drugs also creates the possibility of using the same affinity microcolumn to study and measure the free fractions for a variety of pharmaceutical agents. These properties make this technique appealing for use in drug-binding studies and in the high-throughput screening of new drug candidates.
Collapse
Affiliation(s)
- Rangan Mallik
- Chemistry Department, University of Nebraska, Lincoln, NE 68588-0304, USA
| | | | | | | |
Collapse
|
7
|
Nelson MA, Moser A, Hage DS. Biointeraction analysis by high-performance affinity chromatography: Kinetic studies of immobilized antibodies. J Chromatogr B Analyt Technol Biomed Life Sci 2010; 878:165-71. [PMID: 19394281 PMCID: PMC2817957 DOI: 10.1016/j.jchromb.2009.04.004] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2009] [Revised: 03/22/2009] [Accepted: 04/01/2009] [Indexed: 11/26/2022]
Abstract
A system based on high-performance affinity chromatography was developed for characterizing the binding, elution and regeneration kinetics of immobilized antibodies and immunoaffinity supports. This information was provided by using a combination of frontal analysis, split-peak analysis and peak decay analysis to determine the rate constants for antibody-antigen interactions under typical sample application and elution conditions. This technique was tested using immunoaffinity supports that contained monoclonal antibodies for 2,4-dichlorophenoxyacetic acid (2,4-D). Association equilibrium constants measured by frontal analysis for 2,4-D and related compounds with the immobilized antibodies were 1.7-12x10(6)M(-1) at pH 7.0 and 25 degrees C. Split-peak analysis gave association rate constants of 1.4-12x10(5)M(-1)s(-1) and calculated dissociation rate constants of 0.01-0.4s(-1) under the application conditions. Elution at pH 2.5 for the analytes from the antibodies was examined by peak decay analysis and gave dissociation rate constants of 0.056-0.17s(-1). A comparison of frontal analysis results after various periods of column regeneration allowed the rate of antibody regeneration to be examined, with the results giving a first-order regeneration rate constant of 2.4x10(-4)s(-1). This combined approach and the information it provides should be useful in the design and optimization of immunoaffinity chromatography and other analytical methods that employ immobilized antibodies. The methods described are not limited to the particular analytes and antibodies employed in this study but should be useful in characterizing other targets, ligands and supports.
Collapse
Affiliation(s)
- Mary Anne Nelson
- Chemistry Department, University of Nebraska, 704 Hamilton Hall, Lincoln, Nebraska 68588-0304
| | - Annette Moser
- Chemistry Department, University of Nebraska, 704 Hamilton Hall, Lincoln, Nebraska 68588-0304
| | - David S. Hage
- Chemistry Department, University of Nebraska, 704 Hamilton Hall, Lincoln, Nebraska 68588-0304
| |
Collapse
|
8
|
Chen J, Schiel JE, Hage DS. Noncompetitive peak decay analysis of drug-protein dissociation by high-performance affinity chromatography. J Sep Sci 2009; 32:1632-41. [PMID: 19472288 DOI: 10.1002/jssc.200900074] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The peak decay method is an affinity chromatographic technique that has been used to examine the dissociation of solutes from immobilized ligands in the presence of excess displacing agent. However, it can be difficult to find a displacing agent that does not interfere with detection of the eluting analyte. In this study, a noncompetitive peak decay method was developed in which no displacing agent was required for analyte elution. This method was evaluated for the study of drug-protein interactions by using it along with high-performance affinity chromatography to measure the dissociation rate constants for R- and S-warfarin from columns containing immobilized HSA. Several factors were considered in the optimization of this method, including the amount of applied analyte, the column size, and the flow rate. The dissociation rate constants for R- and S-warfarin from HSA were measured at several temperatures by this approach, giving values of 0.56 (+/-0.01) and 0.66 (+/-0.01) s(-1) at pH 7.4 and 37 degrees C. These results were in good agreement with previous values obtained by other methods. This approach is not limited to warfarin and HSA but could be employed in studying additional drug-protein interactions or other systems with weak-to-moderate binding.
Collapse
Affiliation(s)
- Jianzhong Chen
- Chemistry Department, University of Nebraska, Lincoln, Nebraska 68588-0304, USA
| | | | | |
Collapse
|
9
|
Wa C, Mallik R, Hage DS. Development of immunoaffinity restricted access media for rapid extractions of low-mass analytes. Anal Chem 2008; 80:8751-62. [PMID: 18937423 DOI: 10.1021/ac801233t] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Restricted access media using antibodies as immobilized ligands were developed for the rapid and selective capture of small analytes by immunoextraction, giving rise to materials referred to as immunoaffinity restricted access media (IA-RAM). To make such a material, intact antibodies for the desired target were first immobilized onto porous silica, with antibodies at or near the outer surface of the support then being treated with papain (or a related agent) to release and remove their binding domains. The result was a support in which only antibodies deep within the pores remained intact and able to bind to the target. Items evaluated in the development of such media included the immobilization method used for the antibodies, the pore size of the support, and the amount of papain and time that were used for support treatment. A theoretical model was also developed to describe the extent of binding domain removal based on the measured polypeptide content of the IA-RAM support before and after treatment with papain. The final optimized conditions for making the IA-RAM supports were used to prepare columns that contained antifluorescein antibodies. Injections of fluorescein and fluorescein-labeled bovine serum albumin onto these IA-RAM columns gave selective and quantitative extraction of fluorescein in 1-2 s. This approach can be used with other antibodies and low-mass targets and should be valuable for such applications as the rapid separation of drugs from drug-protein complexes or the isolation of labeled/modified peptides from intact proteins that contain the same modification or label.
Collapse
Affiliation(s)
- Chunling Wa
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, USA
| | | | | |
Collapse
|
10
|
Peoples MC, Karnes HT. Microfluidic immunoaffinity separations for bioanalysis. J Chromatogr B Analyt Technol Biomed Life Sci 2008; 866:14-25. [PMID: 17869593 DOI: 10.1016/j.jchromb.2007.08.030] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2007] [Revised: 08/13/2007] [Accepted: 08/14/2007] [Indexed: 10/22/2022]
Abstract
Microfluidic devices often rely on antibody-antigen interactions as a means of separating analytes of interest from sample matrices. Immunoassays and immunoaffinity separations performed in miniaturized formats offer selective target isolation with minimal reagent consumption and reduced analysis times. The introduction of biological fluids and other complicated matrices often requires sample pretreatment or system modifications for compatibility with small-scale devices. Miniaturization of external equipment facilitates the potential for portable use such as in patient point-of-care settings. Microfluidic immunoaffinity systems including capillary and chip platforms have been assembled from basic instrument components for fluid control, sample introduction, and detection. The current review focuses on the use of immunoaffinity separations in microfluidic devices with an emphasis on pump-based flow and biological sample analysis.
Collapse
Affiliation(s)
- Michael C Peoples
- Department of Pharmaceutics, Virginia Commonwealth University Medical Center, Richmond, VA 23298-0533, USA
| | | |
Collapse
|
11
|
Ohnmacht CM, Schiel JE, Hage DS. Analysis of free drug fractions using near-infrared fluorescent labels and an ultrafast immunoextraction/displacement assay. Anal Chem 2007; 78:7547-56. [PMID: 17073425 PMCID: PMC2533129 DOI: 10.1021/ac061215f] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A chromatographic method was developed for measuring free drug fractions based on the use of an ultrafast immunoextraction/displacement assay (UFIDA) with near-infrared (NIR) fluorescent labels. This approach was evaluated by using it to determine the free fraction of phenytoin in serum or samples containing the binding protein human serum albumin (HSA). Items considered in the design of this method included the dissociation rate of HSA-bound phenytoin, the rate of capture of free phenytoin by immunoextraction microcolumns, the behavior of NIR fluorescent labels in a displacement format, and the overall response and stability of the resulting assay. In the final UFIDA method, the free fraction of phenytoin was extracted in approximately 100 ms by a microcolumn containing a small layer of anti-phenytoin antibodies. This gave a displacement peak for a NIR-fluorescent-labeled analogue of phenytoin that appeared within 2-3 min of sample injection, creating a signal proportional to the amount of free phenytoin in the sample. The UFIDA method provided results within 1-5% of those determined by ultrafiltration for reference samples. The lower limit of detection was 570 pM, and the linear range extended up to 10 microM. This approach is not limited to phenytoin but can be adapted for other analytes through the use of appropriate antibodies and labeled analogues.
Collapse
Affiliation(s)
| | | | - David S. Hage
- Author for correspondence. Phone: (402) 472−2744; FAX: (402) 472−9402;
| |
Collapse
|
12
|
Abstract
Affinity monoliths based on a copolymer of glycidyl methacrylate and ethylene dimethacrylate were developed for ultrafast immunoextractions. Rabbit immunoglobulin G (IgG) and anti-FITC antibodies were used as model ligands for this work. The antibody content of the monoliths was optimized by varying both the polymerization and immobilization conditions for preparing such supports. The temperature and porogen composition used during polymerization showed significant effects on monolith morphology and on the amount of antibodies that could be coupled to these materials. The effects of various immobilization procedures and coupling conditions were also evaluated, including the coupling temperature, pH, protein concentration, and use of high buffer concentrations. The maximum ligand density obtained for rabbit IgG was approximately 60 mg/g. When a 4.5 mm i.d. x 0.95 mm monolith disk containing anti-FITC antibodies was used, 95% extraction of fluorescein was achieved in 100 ms. These properties make such monoliths attractive for work in the rapid isolation of analytes from biological samples. Similar columns can be developed for other targets by varying the types of antibodies or binding agents placed within the monoliths.
Collapse
Affiliation(s)
- Tao Jiang
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, USA
| | | | | |
Collapse
|
13
|
Clarke W, Schiel JE, Moser A, Hage DS. Analysis of free hormone fractions by an ultrafast immunoextraction/displacement immunoassay: studies using free thyroxine as a model system. Anal Chem 2007; 77:1859-66. [PMID: 15762597 DOI: 10.1021/ac040127x] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A system was developed for measuring the noncomplexed or free fraction of a hormone in serum based on the combined use of ultrafast immunoextraction with a chromatographic displacement immunoassay. This approach was tested using L-thyroxine as a model analyte. Items considered in the development of this technique included the choice of immunoassay format and the selection of conditions for removal of thyroxine's free fraction from samples without significant interference from its protein-bound fraction. The final method had an effective extraction time of 90 ms and allowed the amount of free thyroxine to be determined within 30 s after sample injection. The limit of detection was 6 pM (S/N = 3) for a 100-microL sample, and the linear response extended up to at least 100 pM. This technique gave good correlation versus reference methods when used for the determination of free thyroxine in serum samples. Advantages of this method included its speed and its ability to analyze a sample with no pretreatment other than standard filtration. The same approach could be adapted for other hormones or drugs by using appropriate antibodies and labeled analogues for such agents.
Collapse
Affiliation(s)
- William Clarke
- Department of Chemistry, University of Nebraska, Lincoln, Nebraska 68588-0304, USA
| | | | | | | |
Collapse
|
14
|
Hage DS. High-performance affinity chromatography: a powerful tool for studying serum protein binding. J Chromatogr B Analyt Technol Biomed Life Sci 2002; 768:3-30. [PMID: 11939555 DOI: 10.1016/s0378-4347(01)00482-0] [Citation(s) in RCA: 173] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
High-performance affinity chromatography (HPAC) is a method in which a biologically-related ligand is used as a stationary phase in an HPLC system. This approach is a powerful means for selectively isolating or quantitating agents in complex samples, but it can also be employed to study the interactions of biological systems. In recent years there have been numerous reports in which HPAC has been used to examine the interactions of drugs, hormones and other substances with serum proteins. This review discusses how HPAC has been used in such work. Particular attention is given to the techniques of zonal elution and frontal analysis. Various applications are provided for these techniques, along with a list of factors that need to be considered in their optimization and use. New approaches based on band-broadening studies and rapid immunoextraction are also discussed.
Collapse
Affiliation(s)
- David S Hage
- University of Nebraska-Lincoln, Department of Chemistry, 68588-0304, USA.
| |
Collapse
|