1
|
Liu Y, Zhang J, Li Y, Zhao Y, Kuermanbayi S, Zhuang J, Zhang H, Xu F, Li F. Matrix stiffness-dependent microglia activation in response to inflammatory cues: in situ investigation by scanning electrochemical microscopy. Chem Sci 2023; 15:171-184. [PMID: 38131065 PMCID: PMC10732011 DOI: 10.1039/d3sc03504b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Accepted: 11/26/2023] [Indexed: 12/23/2023] Open
Abstract
Microglia play a crucial role in maintaining the homeostasis of the central nervous system (CNS) by sensing and responding to mechanical and inflammatory cues in their microenvironment. However, the interplay between mechanical and inflammatory cues in regulating microglia activation remains elusive. In this work, we constructed in vitro mechanical-inflammatory coupled microenvironment models of microglia by culturing BV2 cells (a murine microglial cell line) on polyacrylamide gels with tunable stiffness and incorporating a lipopolysaccharide (LPS) to mimic the physiological and pathological microenvironment of microglia in the hippocampus. Through characterization of activation-related proteins, cytokines, and reactive oxygen species (ROS) levels, we observed that the LPS treatment induced microglia on a stiff matrix to exhibit overexpression of NOX2, higher levels of ROS and inflammatory factors compared to those on a soft matrix. Additionally, using scanning electrochemical microscopy (SECM), we performed in situ characterization and discovered that microglia on a stiff matrix promoted extracellular ROS production, leading to a disruption in their redox balance and increased susceptibility to LPS-induced ROS production. Furthermore, the respiratory activity and migration behavior of microglia were closely associated with their activation process, with the stiff matrix-LPS-induced microglia demonstrating the most pronounced changes in respiratory activity and migration ability. This work represents the first in situ and dynamic monitoring of microglia activation state alterations under a mechanical-inflammatory coupled microenvironment using SECM. Our findings shed light on matrix stiffness-dependent activation of microglia in response to an inflammatory microenvironment, providing valuable insights into the mechanisms underlying neuroinflammatory processes in the CNS.
Collapse
Affiliation(s)
- Yulin Liu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University Xi'an 710049 P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University Xi'an 710049 P. R. China
| | - Junjie Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University Xi'an 710049 P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University Xi'an 710049 P. R. China
| | - Yabei Li
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University Xi'an 710049 P. R. China
- School of Chemistry, Xi'an Jiaotong University Xi'an 710049 P. R. China
| | - Yuxiang Zhao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University Xi'an 710049 P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University Xi'an 710049 P. R. China
| | - Shuake Kuermanbayi
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University Xi'an 710049 P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University Xi'an 710049 P. R. China
| | - Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, School of Mechanical Engineering, Xi'an Jiaotong University Xi'an 710049 P. R. China
| | - Hua Zhang
- Department of Neurosurgery, The First Affiliated Hospital, Xi'an Jiaotong University Xi'an 710061 P. R. China
| | - Feng Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University Xi'an 710049 P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University Xi'an 710049 P. R. China
| | - Fei Li
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University Xi'an 710049 P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University Xi'an 710049 P. R. China
| |
Collapse
|
2
|
Zhu F, Liu Z, Wu X, Xu D, Li Q, Chen X, Pang W, Duan X, Wang Y. Enhanced on-Chip modification and intracellular hydrogen peroxide detection via gigahertz acoustic streaming microfluidic platform. ULTRASONICS SONOCHEMISTRY 2023; 100:106618. [PMID: 37769590 PMCID: PMC10543187 DOI: 10.1016/j.ultsonch.2023.106618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 09/20/2023] [Accepted: 09/22/2023] [Indexed: 10/03/2023]
Abstract
Developing effective strategies for the flexible control of fluid is vital for microfluidic electrochemical biosensing. In this study, a gigahertz (GHz) acoustic streaming (AS) based sonoelectrochemical system was developed to realize an on-chip surface modification and sensitive hydrogen peroxide (H2O2) detection from living cells. The flexible and controlled fluid surrounding the electrochemical chip was optimized theoretically and applied in the sonoelectrochemical deposition of Au nanoparticles (AuNPs) first. Under the steady and fast flow stimulus of AS, AuNPs could be synthesized with a smaller and evener size distribution than the normal condition, allowing AuNPs to show an excellent peroxidase-like activity. Moreover, the AS also accelerated the mass transport of target molecules and improved the catalytic rate, leading to the enhancement of H2O2 detection, with an extremely low detection limit of 32 nM and a high sensitivity of 4.34 μA/ (mM·mm2). Finally, this system was successfully applied in tracking H2O2 release from different cell lines to distinguish the cancer cells from normal cells. This study innovatively integrated the surface modification and molecules detection process on a chip, and also proposed a simple but sensitive platform for microfluidic biosensing application.
Collapse
Affiliation(s)
- Feng Zhu
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Zeyu Liu
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xiaoyu Wu
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Die Xu
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Quanning Li
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xuejiao Chen
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Wei Pang
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Yanyan Wang
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China.
| |
Collapse
|
3
|
Cremin K, Meloni GN, Valavanis D, Soyer OS, Unwin PR. Can Single Cell Respiration be Measured by Scanning Electrochemical Microscopy (SECM)? ACS MEASUREMENT SCIENCE AU 2023; 3:361-370. [PMID: 37868362 PMCID: PMC10588932 DOI: 10.1021/acsmeasuresciau.3c00019] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 06/13/2023] [Accepted: 06/13/2023] [Indexed: 10/24/2023]
Abstract
Ultramicroelectrode (UME), or, equivalently, microelectrode, probes are increasingly used for single-cell measurements of cellular properties and processes, including physiological activity, such as metabolic fluxes and respiration rates. Major challenges for the sensitivity of such measurements include: (i) the relative magnitude of cellular and UME fluxes (manifested in the current); and (ii) issues around the stability of the UME response over time. To explore the extent to which these factors impact the precision of electrochemical cellular measurements, we undertake a systematic analysis of measurement conditions and experimental parameters for determining single cell respiration rates via the oxygen consumption rate (OCR) in single HeLa cells. Using scanning electrochemical microscopy (SECM), with a platinum UME as the probe, we employ a self-referencing measurement protocol, rarely employed in SECM, whereby the UME is repeatedly approached from bulk solution to a cell, and a short pulse to oxygen reduction reaction (ORR) potential is performed near the cell and in bulk solution. This approach enables the periodic tracking of the bulk UME response to which the near-cell response is repeatedly compared (referenced) and also ensures that the ORR near the cell is performed only briefly, minimizing the effect of the electrochemical process on the cell. SECM experiments are combined with a finite element method (FEM) modeling framework to simulate oxygen diffusion and the UME response. Taking a realistic range of single cell OCR to be 1 × 10-18 to 1 × 10-16 mol s-1, results from the combination of FEM simulations and self-referencing SECM measurements show that these OCR values are at, or below, the present detection sensitivity of the technique. We provide a set of model-based suggestions for improving these measurements in the future but highlight that extraordinary improvements in the stability and precision of SECM measurements will be required if single cell OCR measurements are to be realized.
Collapse
Affiliation(s)
- Kelsey Cremin
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Gabriel N. Meloni
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Dimitrios Valavanis
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Orkun S. Soyer
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
4
|
Pan N, Lu L, Zhang D, Wang X. Evaluation of the effect of nitrate and chloride on Cd(II)-induced cell oxidative stress by scanning electrochemical microscopy. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2673-2681. [PMID: 35762516 DOI: 10.1039/d2ay00495j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Cadmium (Cd) is one of the most prevalent toxic metal pollutants, which is widely distributed in various environmental media and organisms. Literature studies have documented that Cd could stimulate cellular oxidative stress, and the increased intracellular reactive oxygen species (ROS) might destroy certain proteins and DNA and subsequently lead to cell apoptosis. Although several studies have studied the co-exposure between cadmium and other metals, information on the potential effects of Cd and its counterions is still lacking. In the present study, we explored the effects of nitrate and chloride on oxidative stress induced by Cd(II) at environmental exposure levels in human breast cancer cells (MCF-7) using scanning electrochemical microscopy (SECM). After incubation in CdCl2 or Cd(NO3)2, ROS production is concentration-dependent and time-dependent, and the variation trend is consistent. When MCF-7 cells were incubated at a constant Cd2+ concentration, it was found that the higher the concentration ratio of Cd(NO3)2/CdCl2, the less ROS was generated. Combined with cell-viability, intracellular acidification as well as antioxidants system tests, we observed that nitrate could be reduced to nitrite and then inhibit Cd-induced oxidative stress. Benefitting from real-time in situ imaging of cells by SECM, H2O2 was detected and quantified in a noninvasive way, and the effect of Cd at environmental exposure levels on cellular oxidative stress was explored deeper and more comprehensively. Prospectively, cytotoxicological methods based on the SECM technique would be established to explore toxic pollutant co-exposure issues at environmental exposure levels.
Collapse
Affiliation(s)
- Na Pan
- Key Laboratory of Beijing on Regional Air Pollution Control, Department of Environmental Science, Beijing University of Technology, Beijing 100124, P. R. China
| | - Liping Lu
- Key Laboratory of Beijing on Regional Air Pollution Control, Department of Environmental Science, Beijing University of Technology, Beijing 100124, P. R. China
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry and Biology, Beijing University of Technology, Beijing 100124, P. R. China.
| | - Dongtang Zhang
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry and Biology, Beijing University of Technology, Beijing 100124, P. R. China.
| | - Xiayan Wang
- Center of Excellence for Environmental Safety and Biological Effects, Department of Chemistry and Biology, Beijing University of Technology, Beijing 100124, P. R. China.
| |
Collapse
|
5
|
Goines S, Deng M, Glasscott MW, Leung JWC, Dick JE. Enhancing scanning electrochemical microscopy's potential to probe dynamic co-culture systems via hyperspectral assisted-imaging. Analyst 2022; 147:2396-2404. [PMID: 35579029 PMCID: PMC9287841 DOI: 10.1039/d2an00319h] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
Precise determination of boundaries in co-culture systems is difficult to achieve with scanning electrochemical microscopy alone. Thus, biological scanning electrochemical microscope platforms generally consist of a scanning electrochemical microscope positioner mounted on the stage of an inverted microscope for correlated electrochemical and optical imaging. Use of a fluorescence microscope allows for site-specific fluorescence labeling to obtain more clearly resolved spatial and electrochemical data. Here, we construct a unique hyperspectral assisted-biological scanning electrochemical microscope platform to widen the scope of biological imaging. Specifically, we incorporate a variable fluorescence bandpass source into a biological scanning electrochemical microscope platform for simultaneous optical, spectral, and electrochemical imaging. Not only does this platform serve as a cost-effective alternative to white light laser imaging, but additionally it provides multi-functional analysis of biological samples. Here, we demonstrate the efficacy of our platform to discern the electrochemical contribution of site-specific cells by optically and spectroscopically resolving boundaries as well as cell types within a complex biological system.
Collapse
Affiliation(s)
- Sondrica Goines
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
| | - Mingchu Deng
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
| | - Matthew W Glasscott
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
| | - Justin W C Leung
- Department of Radiation Oncology, College of Medicine, University of Arkansas for Medical Sciences, Little Rock, AR 72205, USA
| | - Jeffrey E Dick
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
- Lineberger Comprehensive Cancer Center, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| |
Collapse
|
6
|
Wu T, Xiong Q, Song R, Wang Q, Zhang F, He P. In situ monitoring of the effect of Cu 2+ on the membrane permeability of a single living cell with a dual-electrode tip of a scanning electrochemical microscope. Analyst 2021; 146:7257-7264. [PMID: 34734932 DOI: 10.1039/d1an01656c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Here, an Au-Cu dual-electrode tip was designed to monitor the effect of Cu2+ on the membrane permeability of a single living cell in situ using scanning electrochemical microscopy. The probe approach curves (PACs) were obtained using potassium ferricyanide as a redox mediator. Meanwhile, according to the simulation, theoretical PACs could be acquired. Thus, the cell membrane permeability coefficient (Pm) values were obtained by overlapping the experimental PACs with the theoretical values. Cu2+ was directly generated by electrolyzing the Cu electrode of the dual-electrode tip to investigate its effect on the cell membrane permeability in situ. This work has potential value to improve the understanding of the mechanism of acute heavy metal damage on the cell membrane and will also help clarify the role of heavy metal ions in physiological or pathological processes.
Collapse
Affiliation(s)
- Tao Wu
- School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai 200241, P.R. China.
| | - Qiang Xiong
- School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai 200241, P.R. China.
| | - Ranran Song
- School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai 200241, P.R. China.
| | - Qingjiang Wang
- School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai 200241, P.R. China.
| | - Fan Zhang
- School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai 200241, P.R. China.
| | - Pingang He
- School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai 200241, P.R. China.
| |
Collapse
|
7
|
McCormick HK, Dick JE. Nanoelectrochemical quantification of single-cell metabolism. Anal Bioanal Chem 2020; 413:17-24. [PMID: 32915282 DOI: 10.1007/s00216-020-02899-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 08/10/2020] [Accepted: 08/18/2020] [Indexed: 12/12/2022]
Abstract
At the most fundamental level, the behavior of tissue is governed by the activity of its single cells. A detailed examination of single-cell biology is necessary in order to gain a deeper understanding of disease progression. While single-cell genomics and transcriptomics are mature due to robust amplification strategies, the metabolome is difficult to quantify. Nanoelectrochemical techniques stand poised to quantify single-cell metabolism as a result of the fabrication of nanoelectrodes, which allow one to make intracellular electrochemical measurements. This article is concerned with intracellular nanoelectrochemistry, focusing on the sensitive and selective quantification of various metabolites within a single, living cell. We will review the strong literature behind this field, discuss the potential deleterious effects of passing charge inside cells, and provide future outlooks for this promising avenue of inquiry. We also present a mathematical relationship based on Faraday's Law and bulk electrolysis theory to examine the consumption of analyte within a cell due to passing charge at the nanotip.Graphical abstract.
Collapse
Affiliation(s)
- Hadley K McCormick
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA
| | - Jeffrey E Dick
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA. .,Lineberger Comprehensive Cancer Center, School of Medicine, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599, USA.
| |
Collapse
|
8
|
Caniglia G, Kranz C. Scanning electrochemical microscopy and its potential for studying biofilms and antimicrobial coatings. Anal Bioanal Chem 2020; 412:6133-6148. [PMID: 32691088 PMCID: PMC7442582 DOI: 10.1007/s00216-020-02782-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 06/08/2020] [Accepted: 06/19/2020] [Indexed: 02/06/2023]
Abstract
Biofilms are known to be well-organized microbial communities embedded in an extracellular polymeric matrix, which supplies bacterial protection against external stressors. Biofilms are widespread and diverse, and despite the considerable large number of publications and efforts reported regarding composition, structure and cell-to-cell communication within biofilms in the last decades, the mechanisms of biofilm formation, the interaction and communication between bacteria are still not fully understood. This knowledge is required to understand why biofilms form and how we can combat them or how we can take advantage of these sessile communities, e.g. in biofuel cells. Therefore, in situ and real-time monitoring of nutrients, metabolites and quorum sensing molecules is of high importance, which may help to fill that knowledge gap. This review focuses on the potential of scanning electrochemical microscopy (SECM) as a versatile method for in situ studies providing temporal and lateral resolution in order to elucidate cell-to-cell communication, microbial metabolism and antimicrobial impact, e.g. of antimicrobial coatings through the study of electrochemical active molecules. Given the complexity and diversity of biofilms, challenges and limitations will be also discussed.
Collapse
Affiliation(s)
- Giada Caniglia
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee, 11, 89081, Ulm, Germany
| | - Christine Kranz
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee, 11, 89081, Ulm, Germany.
| |
Collapse
|
9
|
Huang J, Hou L, Bian X, Chang K. Analysis of intracellular reactive oxygen species by micellar electrokinetic capillary chromatography with laser-induced-fluorescence detector. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2019.1625369] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Jianping Huang
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, China
- Henan Engineering Research Center of Water Pollution and Soil Damage Remediation, Zhengzhou, China
- Henan Key Laboratory of Water Environment Simulation and Treatment, Zhengzhou, China
| | - Lijun Hou
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, China
| | - Xiaozheng Bian
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, China
| | - Kai Chang
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, China
| |
Collapse
|
10
|
Patrice FT, Qiu K, Ying YL, Long YT. Single Nanoparticle Electrochemistry. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:347-370. [PMID: 31018101 DOI: 10.1146/annurev-anchem-061318-114902] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Experimental techniques to monitor and visualize the behaviors of single nanoparticles have not only revealed the significant spatial and temporal heterogeneity of those individuals, which are hidden in ensemble methods, but more importantly, they have also enabled researchers to elucidate the origin of such heterogeneity. In pursuing the intrinsic structure-function relations of single nanoparticles, the recently developed stochastic collision approach demonstrated some early promise. However, it was later realized that the appropriate sizing of a single nanoparticle by an electrochemical method could be far more challenging than initially expected owing to the dynamic motion of nanoparticles in electrolytes and complex charge-transfer characteristics at electrode surfaces. This clearly indicates a strong necessity to integrate single nanoparticle electrochemistry with high-resolution optical microscopy. Hence, this review aims to give a timely update of the latest progress for both electrochemically sensing and seeing single nanoparticles. A major focus is on collision-based measurements, where nanoparticles or single entities in solution impact on a collector electrode and the electrochemical response is recorded. These measurements are further enhanced with optical measurements in parallel. For completeness, advances in other related methods for single nanoparticle electrochemistry are also included.
Collapse
Affiliation(s)
- Fato Tano Patrice
- School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China; ;
| | - Kaipei Qiu
- School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China; ;
| | - Yi-Lun Ying
- School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China; ;
| | - Yi-Tao Long
- School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China; ;
- State Key Laboratory of Analytical Chemistry for Life Sciences, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| |
Collapse
|
11
|
Guerret-Legras L, Audibert J, Ojeda IG, Dubacheva G, Miomandre F. Combined SECM-fluorescence microscopy using a water-soluble electrofluorochromic dye as the redox mediator. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.03.069] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
12
|
Okumura S, Hirano Y, Maki Y, Komatsu Y. Analysis of time-course drug response in rat cardiomyocytes cultured on a pattern of islands. Analyst 2019; 143:4083-4089. [PMID: 30083681 DOI: 10.1039/c8an01033a] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
We previously reported the kinetics analysis of cardiomyocyte beating using scanning electrochemical microscopy (SECM). In this study, a stage-top incubator and a capillary micropipette (MP) for delivering drugs were assembled with an SECM instrument, and the responses of rat cardiomyocytes were analyzed under a culture environment after drug stimulation. When adenosine triphosphate (ATP) was delivered to synchronously beating cardiomyocytes, the beating acceleration effect of ATP was counteracted by the synchronously beating network in the culture dish. In contrast, cardiomyocytes cultured on a pattern of islands in a culture dish showed fluctuations in the duration of beating upon the addition of ATP. We also examined the effect of the cardiotoxic agent astemizole on cardiomyocytes and successfully detected motion fluctuations. Therefore, drug stimulation via MPs and beating measurement by SECM are effective routes for the evaluation of drug candidates through the analysis of time-course beating motion fluctuations of the cardiomyocytes.
Collapse
|
13
|
Arthur PK, Yeboah AB, Issah I, Balapangu S, Kwofie SK, Asimeng BO, Foster EJ, Tiburu EK. Electrochemical Response of Saccharomyces cerevisiae Corresponds to Cell Viability upon Exposure to Dioclea reflexa Seed Extracts and Antifungal Drugs. BIOSENSORS-BASEL 2019; 9:bios9010045. [PMID: 30897802 PMCID: PMC6468906 DOI: 10.3390/bios9010045] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 02/11/2019] [Accepted: 03/02/2019] [Indexed: 12/20/2022]
Abstract
Dioclea reflexa bioactive compounds have been shown to contain antioxidant properties. The extracts from the same plant are used in traditional medical practices to treat various diseases with impressive outcomes. In this study, ionic mobility in Saccharomyces cerevisiae cells in the presence of D. reflexa seed extracts was monitored using electrochemical detection methods to link cell death to ionic imbalance. Cells treated with ethanol, methanol, and water extracts were studied using cyclic voltammetry and cell counting to correlate electrochemical behavior and cell viability, respectively. The results were compared with cells treated with pore-forming Amphotericin b (Amp b), as well as Fluconazole (Flu) and the antimicrobial drug Rifampicin (Rif). The D. reflexa seed water extract (SWE) revealed higher anodic peak current with 58% cell death. Seed methanol extract (SME) and seed ethanol extract (SEE) recorded 31% and 22% cell death, respectively. Among the three control drugs, Flu revealed the highest cell death of about 64%, whereas Amp b and Rif exhibited cell deaths of 35% and 16%, respectively, after 8 h of cell growth. It was observed that similar to SWE, there was an increase in the anodic peak current in the presence of different concentrations of Amp b, which also correlated with enhanced cell death. It was concluded from this observation that Amp b and SWE might follow similar mechanisms to inhibit cell growth. Thus, the individual bioactive compounds from the water extracts of D. reflexa seeds could further be purified and tested to validate their potential therapeutic application. The strategy to link electrochemical behavior to biochemical responses could be a simple, fast, and robust screening technique for new drug targets and to understand the mechanism of action of such drugs against disease models.
Collapse
Affiliation(s)
- Patrick Kobina Arthur
- Department of Biochemistry, Cell and Molecular Biology, University of Ghana, Legon P.O. Box LG 54, Ghana.
- West African Centre for Cell Biology of Infectious Pathogens, University of Ghana, Legon P.O. Box LG 54, Ghana.
| | - Anthony Boadi Yeboah
- Department of Biomedical Engineering, School of Engineering Sciences, College of Basic and Applied Sciences, University of Ghana, Legon P.O. Box LG 25, Ghana.
| | - Ibrahim Issah
- Department of Biomedical Engineering, School of Engineering Sciences, College of Basic and Applied Sciences, University of Ghana, Legon P.O. Box LG 25, Ghana.
| | - Srinivasan Balapangu
- West African Centre for Cell Biology of Infectious Pathogens, University of Ghana, Legon P.O. Box LG 54, Ghana.
- Department of Biomedical Engineering, School of Engineering Sciences, College of Basic and Applied Sciences, University of Ghana, Legon P.O. Box LG 25, Ghana.
| | - Samuel K Kwofie
- West African Centre for Cell Biology of Infectious Pathogens, University of Ghana, Legon P.O. Box LG 54, Ghana.
- Department of Biomedical Engineering, School of Engineering Sciences, College of Basic and Applied Sciences, University of Ghana, Legon P.O. Box LG 25, Ghana.
- Department of Medicine, Loyola University Medical Center, Chicago, IL 60153, USA.
| | - Bernard O Asimeng
- Department of Biomedical Engineering, School of Engineering Sciences, College of Basic and Applied Sciences, University of Ghana, Legon P.O. Box LG 25, Ghana.
| | - E Johan Foster
- Department of Materials Science and Engineering, Virginia Tech, Blacksburg, VA 24061, USA.
| | - Elvis K Tiburu
- West African Centre for Cell Biology of Infectious Pathogens, University of Ghana, Legon P.O. Box LG 54, Ghana.
- Department of Biomedical Engineering, School of Engineering Sciences, College of Basic and Applied Sciences, University of Ghana, Legon P.O. Box LG 25, Ghana.
| |
Collapse
|
14
|
Filice F, Henderson JD, Li MSM, Ding Z. Correlating Live Cell Viability with Membrane Permeability Disruption Induced by Trivalent Chromium. ACS OMEGA 2019; 4:2142-2151. [PMID: 30775648 PMCID: PMC6374964 DOI: 10.1021/acsomega.8b02113] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Accepted: 12/18/2018] [Indexed: 06/09/2023]
Abstract
Cr(III) is often regarded as a trace essential micronutrient that can be found in many dietary supplements due to its participation in blood glucose regulation. However, increased levels of exposure have been linked to adverse health effects in living organisms. Herein, scanning electrochemical microscopy (SECM) was used to detect variation in membrane permeability of single cells (T24) resulting from exposure to a trivalent Cr-salt, CrCl3. By employing electrochemical mediators, ferrocenemethanol (FcMeOH) and ferrocenecarboxylic acid (FcCOO-), initially semipermeable and impermeable, respectively, complementary information was obtained. Three-dimensional COMSOL finite element analysis simulations were successfully used to quantify the permeability coefficients of each mediator by matching experimental and simulated results. Depending on the concentration of Cr(III) administered, three regions of membrane response were detected. Following exposure to low concentrations (up to 500 μM Cr(III)), their permeability coefficients were comparable to that of control cells, 80 μm/s for FcMeOH and 0 μm/s for FcCOO-. This was confirmed for both mediators. As the incubation concentrations were increased, the ability of FcMeOH to permeate the membrane decreased to a minimum of 17 μm/s at 7500 μM Cr(III), while FcCOO- remained impermeable. At the highest examined concentrations, both mediators were found to demonstrate increased membrane permeability. 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide cell viability studies were also conducted on Cr(III)-treated T24 cells to correlate the SECM findings with the toxicity effects of the metal. The viability experiments revealed a similar concentration-dependent trend to the SECM cell membrane permeability study.
Collapse
Affiliation(s)
| | | | | | - Zhifeng Ding
- E-mail: . Tel: +1 519 661 2111x86161. Fax: +1 519 661
3022
| |
Collapse
|
15
|
Filice FP, Ding Z. Analysing single live cells by scanning electrochemical microscopy. Analyst 2019; 144:738-752. [DOI: 10.1039/c8an01490f] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Scanning electrochemical microscopy (SECM) offers single live cell activities along its topography toward cellular physiology and pathology.
Collapse
Affiliation(s)
- Fraser P. Filice
- Department of Chemistry
- The University of Western Ontario
- London
- Canada
| | - Zhifeng Ding
- Department of Chemistry
- The University of Western Ontario
- London
- Canada
| |
Collapse
|
16
|
Voci S, Goudeau B, Valenti G, Lesch A, Jović M, Rapino S, Paolucci F, Arbault S, Sojic N. Surface-Confined Electrochemiluminescence Microscopy of Cell Membranes. J Am Chem Soc 2018; 140:14753-14760. [PMID: 30336008 DOI: 10.1021/jacs.8b08080] [Citation(s) in RCA: 183] [Impact Index Per Article: 30.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Herein is reported a surface-confined microscopy based on electrochemiluminescence (ECL) that allows to image the plasma membrane of single cells at the interface with an electrode. By analyzing photoluminescence (PL), ECL and AFM images of mammalian CHO cells, we demonstrate that, in contrast to the wide-field fluorescence, ECL emission is confined to the immediate vicinity of the electrode surface and only the basal membrane of the cell becomes luminescent. The resulting ECL microscopy reveals details that are not resolved by classic fluorescence microscopy, without any light irradiation and specific setup. The thickness of the ECL-emitting regions is ∼500 nm due to the unique ECL mechanism that involves short-lifetime electrogenerated radicals. In addition, the reported ECL microscopy is a dynamic technique that reflects the transport properties through the cell membranes and not only the specific labeling of the membranes. Finally, disposable transparent carbon nanotube (CNT)-based electrodes inkjet-printed on classic microscope glass coverslips were used to image cells in both reflection and transmission configurations. Therefore, our approach opens new avenues for ECL as a surface-confined microscopy to develop single cell assays and to image the dynamics of biological entities in cells or in membranes.
Collapse
Affiliation(s)
- Silvia Voci
- University of Bordeaux , Bordeaux INP, ISM, UMR CNRS 5255 , 33607 Pessac , France
| | - Bertrand Goudeau
- University of Bordeaux , Bordeaux INP, ISM, UMR CNRS 5255 , 33607 Pessac , France
| | - Giovanni Valenti
- Department of Chemistry "G. Ciamician" , University of Bologna , Via Selmi 2 , 40126 Bologna , Italy
| | - Andreas Lesch
- Laboratory of Physical and Analytical Electrochemistry , EPFL Valais Wallis , Rue de l'Industrie 17, CP 440 , CH-1951 Sion , Switzerland
| | - Milica Jović
- Laboratory of Physical and Analytical Electrochemistry , EPFL Valais Wallis , Rue de l'Industrie 17, CP 440 , CH-1951 Sion , Switzerland
| | - Stefania Rapino
- Department of Chemistry "G. Ciamician" , University of Bologna , Via Selmi 2 , 40126 Bologna , Italy
| | - Francesco Paolucci
- Department of Chemistry "G. Ciamician" , University of Bologna , Via Selmi 2 , 40126 Bologna , Italy
| | - Stéphane Arbault
- University of Bordeaux , Bordeaux INP, ISM, UMR CNRS 5255 , 33607 Pessac , France
| | - Neso Sojic
- University of Bordeaux , Bordeaux INP, ISM, UMR CNRS 5255 , 33607 Pessac , France
| |
Collapse
|
17
|
Neves MMPDS, Martín-Yerga D. Advanced Nanoscale Approaches to Single-(Bio)entity Sensing and Imaging. BIOSENSORS 2018; 8:E100. [PMID: 30373209 PMCID: PMC6316691 DOI: 10.3390/bios8040100] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2018] [Revised: 10/11/2018] [Accepted: 10/23/2018] [Indexed: 01/01/2023]
Abstract
Individual (bio)chemical entities could show a very heterogeneous behaviour under the same conditions that could be relevant in many biological processes of significance in the life sciences. Conventional detection approaches are only able to detect the average response of an ensemble of entities and assume that all entities are identical. From this perspective, important information about the heterogeneities or rare (stochastic) events happening in individual entities would remain unseen. Some nanoscale tools present interesting physicochemical properties that enable the possibility to detect systems at the single-entity level, acquiring richer information than conventional methods. In this review, we introduce the foundations and the latest advances of several nanoscale approaches to sensing and imaging individual (bio)entities using nanoprobes, nanopores, nanoimpacts, nanoplasmonics and nanomachines. Several (bio)entities such as cells, proteins, nucleic acids, vesicles and viruses are specifically considered. These nanoscale approaches provide a wide and complete toolbox for the study of many biological systems at the single-entity level.
Collapse
Affiliation(s)
| | - Daniel Martín-Yerga
- Department of Chemical Engineering, KTH Royal Institute of Technology, 100-44 Stockholm, Sweden.
| |
Collapse
|
18
|
Filice FP, Li MSM, Ding Z. Simulation Assisted Nanoscale Imaging of Single Live Cells with Scanning Electrochemical Microscopy. ADVANCED THEORY AND SIMULATIONS 2018. [DOI: 10.1002/adts.201800124] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Fraser P. Filice
- Department of ChemistryUniversity of Western Ontario 1151 Richmond Street London Ontario N6A 5B7 Canada
| | - Michelle S. M. Li
- Department of ChemistryUniversity of Western Ontario 1151 Richmond Street London Ontario N6A 5B7 Canada
| | - Zhifeng Ding
- Department of ChemistryUniversity of Western Ontario 1151 Richmond Street London Ontario N6A 5B7 Canada
| |
Collapse
|
19
|
Conzuelo F, Schulte A, Schuhmann W. Biological imaging with scanning electrochemical microscopy. Proc Math Phys Eng Sci 2018; 474:20180409. [PMID: 30839832 PMCID: PMC6237495 DOI: 10.1098/rspa.2018.0409] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2018] [Accepted: 09/04/2018] [Indexed: 12/27/2022] Open
Abstract
Scanning electrochemical microscopy (SECM) is a powerful and versatile technique for visualizing the local electrochemical activity of a surface as an ultramicroelectrode tip is moved towards or over a sample of interest using precise positioning systems. In comparison with other scanning probe techniques, SECM not only enables topographical surface mapping but also gathers chemical information with high spatial resolution. Considerable progress has been made in the analysis of biological samples, including living cells and immobilized biomacromolecules such as enzymes, antibodies and DNA fragments. Moreover, combinations of SECM with comple-mentary analytical tools broadened its applicability and facilitated multi-functional analysis with extended life science capabilities. The aim of this review is to present a brief topical overview on recent applications of biological SECM, with particular emphasis on important technical improvements of this surface imaging technique, recommended applications and future trends.
Collapse
Affiliation(s)
- Felipe Conzuelo
- Analytical Chemistry—Center for Electrochemical Sciences (CES), Faculty for Chemistry and Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, 44780 Bochum, Germany
| | - Albert Schulte
- School of Biomolecular Science and Engineering (BSE), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong 21210, Thailand
| | - Wolfgang Schuhmann
- Analytical Chemistry—Center for Electrochemical Sciences (CES), Faculty for Chemistry and Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, 44780 Bochum, Germany
| |
Collapse
|
20
|
Ozel RE, Bulbul G, Perez J, Pourmand N. Functionalized Quartz Nanopipette for Intracellular Superoxide Sensing: A Tool for Monitoring Reactive Oxygen Species Levels in Single Living Cell. ACS Sens 2018; 3:1316-1321. [PMID: 29893547 DOI: 10.1021/acssensors.8b00185] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Reactive oxygen species (ROS), including superoxide radical anions, are vital components in numerous biological functions, including cell signaling and immune responses. Since ROS react with other biomolecules and oxidize them quickly, it is essential for cells to have superoxide-scavenging enzymes and other regulating enzymes that can catalyze the dismutation of superoxide radical anions into less damaging molecules. Otherwise, ROS overproduction can cause oxidative damage to DNA, proteins, cells, and tissues, damage that is associated with the pathogenesis of a range of neurodegenerative disorders, age-related diseases, and cancer. Understanding the relationship between superoxide and these disorders can help the development of innovative therapies for combating oxidative stress and degeneration of nerve cells. Although methods to quantify ROS already exist, they are indirect, destructive, ambiguous, and/or cannot provide real-time measurements in single cells. In this paper, we report a technique for sensing superoxide radical anions in single living cells using functionalized nanopipettes. These nanopipettes allow us to enter the cell as we measure intracellular ROS concentrations over time. We observed that these devices provide precise real-time measurements that are accurate and not possible to obtain with other conventional techniques.
Collapse
Affiliation(s)
- Rıfat Emrah Ozel
- Department of Biomolecular Engineering, University of California Santa Cruz, Santa Cruz, California 95064, United States
| | - Gonca Bulbul
- Department of Biomolecular Engineering, University of California Santa Cruz, Santa Cruz, California 95064, United States
| | - Joanna Perez
- Department of Biomolecular Engineering, University of California Santa Cruz, Santa Cruz, California 95064, United States
| | - Nader Pourmand
- Department of Biomolecular Engineering, University of California Santa Cruz, Santa Cruz, California 95064, United States
| |
Collapse
|
21
|
Guerret-Legras L, Audibert JF, Dubacheva GV, Miomandre F. Combined scanning electrochemical and fluorescence microscopies using a tetrazine as a single redox and luminescent (electrofluorochromic) probe. Chem Sci 2018; 9:5897-5905. [PMID: 30079203 PMCID: PMC6050531 DOI: 10.1039/c8sc01814f] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Accepted: 05/29/2018] [Indexed: 01/20/2023] Open
Abstract
The possibility of using a single electroactive and luminescent molecule both as a redox mediator and as a fluorophore in an experiment combining in situ Scanning Electrochemical Microscopy (SECM) and epifluorescence microscopy was validated. The usual working modes of SECM, namely positive and negative feedback as well as generation-collection, were used and the fluorescence images, intensity and spectra were recorded for each configuration. The tip potential, tip-substrate distance and, in the case of a conducting substrate, the substrate potential are the parameters that are likely to control the fluorescence. It is shown that the tip can be used to switch on and off the luminescence and that the modulation amplitude maximum is sensitive to the nature of the substrate. Approach curves based on this fluorescence modulation amplitude can be obtained showing a higher sensitivity than the classical electrochemical ones.
Collapse
Affiliation(s)
- L Guerret-Legras
- PPSM , CNRS , Ecole Normale Supérieure Paris-Saclay , Université Paris-Saclay , 61 Avenue Président Wilson, 94235 Cachan , France .
| | - J F Audibert
- PPSM , CNRS , Ecole Normale Supérieure Paris-Saclay , Université Paris-Saclay , 61 Avenue Président Wilson, 94235 Cachan , France .
| | - G V Dubacheva
- PPSM , CNRS , Ecole Normale Supérieure Paris-Saclay , Université Paris-Saclay , 61 Avenue Président Wilson, 94235 Cachan , France .
| | - F Miomandre
- PPSM , CNRS , Ecole Normale Supérieure Paris-Saclay , Université Paris-Saclay , 61 Avenue Président Wilson, 94235 Cachan , France .
| |
Collapse
|
22
|
Bondarenko A, Lin TE, Stupar P, Lesch A, Cortés-Salazar F, Girault HH, Pick H. Fixation and Permeabilization Approaches for Scanning Electrochemical Microscopy of Living Cells. Anal Chem 2016; 88:11436-11443. [DOI: 10.1021/acs.analchem.6b02379] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Affiliation(s)
- Alexandra Bondarenko
- Laboratoire d’Electrochimie
Physique et Analytique, EPFL Valais Wallis, École Polytechnique Fédérale de Lausanne, CH-1951 Sion, Switzerland
| | - Tzu-En Lin
- Laboratoire d’Electrochimie
Physique et Analytique, EPFL Valais Wallis, École Polytechnique Fédérale de Lausanne, CH-1951 Sion, Switzerland
| | - Petar Stupar
- Laboratory of the
Physics of Living Matter, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| | - Andreas Lesch
- Laboratoire d’Electrochimie
Physique et Analytique, EPFL Valais Wallis, École Polytechnique Fédérale de Lausanne, CH-1951 Sion, Switzerland
| | - Fernando Cortés-Salazar
- Laboratoire d’Electrochimie
Physique et Analytique, EPFL Valais Wallis, École Polytechnique Fédérale de Lausanne, CH-1951 Sion, Switzerland
| | - Hubert H. Girault
- Laboratoire d’Electrochimie
Physique et Analytique, EPFL Valais Wallis, École Polytechnique Fédérale de Lausanne, CH-1951 Sion, Switzerland
| | - Horst Pick
- Laboratory of
Physical Chemistry of Polymers and Membranes, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| |
Collapse
|
23
|
Polcari D, Dauphin-Ducharme P, Mauzeroll J. Scanning Electrochemical Microscopy: A Comprehensive Review of Experimental Parameters from 1989 to 2015. Chem Rev 2016; 116:13234-13278. [PMID: 27736057 DOI: 10.1021/acs.chemrev.6b00067] [Citation(s) in RCA: 195] [Impact Index Per Article: 24.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- David Polcari
- Department
of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec Canada, H3A 0B8
| | - Philippe Dauphin-Ducharme
- Department
of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec Canada, H3A 0B8
| | - Janine Mauzeroll
- Department
of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec Canada, H3A 0B8
| |
Collapse
|
24
|
Dick JE. Electrochemical detection of single cancer and healthy cell collisions on a microelectrode. Chem Commun (Camb) 2016; 52:10906-9. [PMID: 27533129 DOI: 10.1039/c6cc04515d] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The electrochemical detection of single cancer cells and healthy cells is reported. Detection was achieved by monitoring the consumption of a single cell's contents upon its collisions with a microelectrode in the presence of surfactant. The electrochemical response between acute lymphoblastic lymphoma T-cells and healthy thymocytes differed by two orders of magnitude.
Collapse
Affiliation(s)
- Jeffrey E Dick
- Center for Electrochemistry, Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, USA.
| |
Collapse
|
25
|
Zhang MN, Ding Z, Long YT. Sensing cisplatin-induced permeation of single live human bladder cancer cells by scanning electrochemical microscopy. Analyst 2016; 140:6054-60. [PMID: 26194058 DOI: 10.1039/c5an01148e] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Cisplatin is a widely used anti-cancer agent, which was believed to trigger apoptosis of cancer cells by forming DNA adducts. However, recent studies evidenced a cisplatin-induced extrinsic apoptotic pathway through interaction with plasma membranes. We present quantitative time-course imaging of cisplatin-induced permeation of ferrocenemethanol to single live human bladder cancer cells (T24) using scanning electrochemical microscopy (SECM). Simultaneous quantification of cellular topography and membrane permeability was realized by running SECM in the depth scan mode. It was demonstrated that the acute addition of cisplatin to the outer environment of T24 cells immediately induced membrane permeability change in 5 min, which indicated a loosened structure of the cellular membrane upon cisplatin dosage. The cisplatin-induced permeation of T24 cells might be a one-step action, an extrinsic mechanism, since the cell response was quick, and no continuous increase in the membrane permeability was observed. The time-lapse SECM depth scan method provided a simple and facile way of monitoring cisplatin-induced membrane permeability changes. Our study is anticipated to lead to a methodology of screening anti-cancer drugs through their interactions with live cells.
Collapse
Affiliation(s)
- Meng-Ni Zhang
- Department of Chemistry, The University of Western Ontario, London, ON, Canada N6A 5B7.
| | | | | |
Collapse
|
26
|
Filice FP, Li MSM, Henderson JD, Ding Z. Mapping Cd²⁺-induced membrane permeability changes of single live cells by means of scanning electrochemical microscopy. Anal Chim Acta 2016; 908:85-94. [PMID: 26826690 DOI: 10.1016/j.aca.2015.12.027] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Revised: 12/12/2015] [Accepted: 12/29/2015] [Indexed: 12/22/2022]
Abstract
Scanning Electrochemical Microscopy (SECM) is a powerful, non-invasive, analytical methodology that can be used to investigate live cell membrane permeability. Depth scan SECM imaging allowed for the generation of 2D current maps of live cells relative to electrode position in the x-z or y-z plane. Depending on resolution, one depth scan image can contain hundreds of probe approach curves (PACs). Individual PACs were obtained by simply extracting vertical cross-sections from the 2D image. These experimental PACs were overlaid onto theoretically generated PACs simulated at specific geometry conditions. Simulations were carried out using 3D models in COMSOL Multiphysics to determine the cell membrane permeability coefficients at different locations on the surface of the cells. Common in literature, theoretical PACs are generated using a 2D axially symmetric geometry. This saves on both compute time and memory utilization. However, due to symmetry limitations of the model, only one experimental PAC right above the cell can be matched with simulated PAC data. Full 3D models in this article were developed for the SECM system of live cells, allowing all experimental PACs over the entire cell to become usable. Cd(2+)-induced membrane permeability changes of single human bladder (T24) cells were investigated at several positions above the cell, displaced from the central axis. The experimental T24 cells under study were incubated with Cd(2+) in varying concentrations. It is experimentally observed that 50 and 100 μM Cd(2+) caused a decrease in membrane permeability, which was uniform across all locations over the cell regardless of Cd(2+) concentration. The Cd(2+) was found to have detrimental effects on the cell, with cells shrinking in size and volume, and the membrane permeability decreasing. A mapping technique for the analysis of the cell membrane permeability under the Cd(2+) stress is realized by the methodology presented.
Collapse
Affiliation(s)
- Fraser P Filice
- Department of Chemistry, The University of Western Ontario, 1151 Richmond Street, London, ON N6A 5B7, Canada
| | - Michelle S M Li
- Department of Chemistry, The University of Western Ontario, 1151 Richmond Street, London, ON N6A 5B7, Canada
| | - Jeffrey D Henderson
- Department of Chemistry, The University of Western Ontario, 1151 Richmond Street, London, ON N6A 5B7, Canada
| | - Zhifeng Ding
- Department of Chemistry, The University of Western Ontario, 1151 Richmond Street, London, ON N6A 5B7, Canada.
| |
Collapse
|
27
|
Yin J, Miao P. Apoptosis Evaluation by Electrochemical Techniques. Chem Asian J 2015; 11:632-41. [DOI: 10.1002/asia.201501045] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2015] [Indexed: 01/22/2023]
Affiliation(s)
- Jian Yin
- CAS Key Lab of Bio-Medical Diagnostics; Suzhou Institute of Biomedical Engineering and Technology; Chinese Academy of Sciences; Suzhou 215163 P.R. China
| | - Peng Miao
- CAS Key Lab of Bio-Medical Diagnostics; Suzhou Institute of Biomedical Engineering and Technology; Chinese Academy of Sciences; Suzhou 215163 P.R. China
- University of Chinese Academy of Sciences; Beijing 100049 P.R. China
| |
Collapse
|
28
|
Holzinger A, Steinbach C, Kranz C. Scanning Electrochemical Microscopy (SECM): Fundamentals and Applications in Life Sciences. ELECTROCHEMICAL STRATEGIES IN DETECTION SCIENCE 2015. [DOI: 10.1039/9781782622529-00125] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
In recent years, scanning electrochemical microscopy (SECM) has made significant contributions to the life sciences. Innovative developments focusing on high-resolution imaging, developing novel operation modes, and combining SECM with complementary optical or scanning probe techniques renders SECM an attractive analytical approach. This chapter gives an introduction to the essential instrumentation and operation principles of SECM for studying biologically-relevant systems. Particular emphasis is given to applications aimed at imaging the activity of biochemical constituents such as enzymes, antibodies, and DNA, which play a pivotal role in biomedical diagnostics. Furthermore, the unique advantages of SECM and combined techniques for studying live cells is highlighted by discussion of selected examples.
Collapse
Affiliation(s)
- Angelika Holzinger
- Institute of Analytical and Bioanalytical Chemistry, University of Ulm 89069 Ulm Germany
| | - Charlotte Steinbach
- Institute of Analytical and Bioanalytical Chemistry, University of Ulm 89069 Ulm Germany
| | - Christine Kranz
- Institute of Analytical and Bioanalytical Chemistry, University of Ulm 89069 Ulm Germany
| |
Collapse
|
29
|
Bondarenko A, Cortés-Salazar F, Gheorghiu M, Gáspár S, Momotenko D, Stanica L, Lesch A, Gheorghiu E, Girault HH. Electrochemical push-pull probe: from scanning electrochemical microscopy to multimodal altering of cell microenvironment. Anal Chem 2015; 87:4479-86. [PMID: 25833001 DOI: 10.1021/acs.analchem.5b00455] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
To understand biological processes at the cellular level, a general approach is to alter the cells' environment and to study their chemical responses. Herein, we present the implementation of an electrochemical push-pull probe, which combines a microfluidic system with a microelectrode, as a tool for locally altering the microenvironment of few adherent living cells by working in two different perturbation modes, namely electrochemical (i.e., electrochemical generation of a chemical effector compound) and microfluidic (i.e., infusion of a chemical effector compound from the pushing microchannel, while simultaneously aspirating it through the pulling channel, thereby focusing the flow between the channels). The effect of several parameters such as flow rate, working distance, and probe inclination angle on the affected area of adherently growing cells was investigated both theoretically and experimentally. As a proof of concept, localized fluorescent labeling and pH changes were purposely introduced to validate the probe as a tool for studying adherent cancer cells through the control over the chemical composition of the extracellular space with high spatiotemporal resolution. A very good agreement between experimental and simulated results showed that the electrochemical perturbation mode enables to affect precisely only a few living cells localized in a high-density cell culture.
Collapse
Affiliation(s)
- Alexandra Bondarenko
- †Laboratoire d'Electrochimie Physique et Analytique, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| | - Fernando Cortés-Salazar
- †Laboratoire d'Electrochimie Physique et Analytique, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| | - Mihaela Gheorghiu
- ‡International Centre of Biodynamics, 1B Intrarea Portocalelor Street, 060101 Bucharest, Romania
| | - Szilveszter Gáspár
- ‡International Centre of Biodynamics, 1B Intrarea Portocalelor Street, 060101 Bucharest, Romania
| | - Dmitry Momotenko
- †Laboratoire d'Electrochimie Physique et Analytique, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| | - Luciana Stanica
- ‡International Centre of Biodynamics, 1B Intrarea Portocalelor Street, 060101 Bucharest, Romania.,§Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania
| | - Andreas Lesch
- †Laboratoire d'Electrochimie Physique et Analytique, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| | - Eugen Gheorghiu
- ‡International Centre of Biodynamics, 1B Intrarea Portocalelor Street, 060101 Bucharest, Romania.,§Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania
| | - Hubert H Girault
- †Laboratoire d'Electrochimie Physique et Analytique, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| |
Collapse
|
30
|
|
31
|
Salamifar SE, Lee S, Lai RY. Electrochemical hydrogen peroxide sensors fabricated using cytochrome c immobilized on macroelectrodes and ultramicroelectrodes. Colloids Surf B Biointerfaces 2014; 123:866-9. [DOI: 10.1016/j.colsurfb.2014.10.033] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2014] [Revised: 10/04/2014] [Accepted: 10/15/2014] [Indexed: 10/24/2022]
|