1
|
Li X, Zou J, He Z, Sun Y, Song X, He W. The interaction between particles and vascular endothelium in blood flow. Adv Drug Deliv Rev 2024; 207:115216. [PMID: 38387770 DOI: 10.1016/j.addr.2024.115216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Revised: 01/25/2024] [Accepted: 02/14/2024] [Indexed: 02/24/2024]
Abstract
Particle-based drug delivery systems have shown promising application potential to treat human diseases; however, an incomplete understanding of their interactions with vascular endothelium in blood flow prevents their inclusion into mainstream clinical applications. The flow performance of nano/micro-sized particles in the blood are disturbed by many external/internal factors, including blood constituents, particle properties, and endothelium bioactivities, affecting the fate of particles in vivo and therapeutic effects for diseases. This review highlights how the blood constituents, hemodynamic environment and particle properties influence the interactions and particle activities in vivo. Moreover, we briefly summarized the structure and functions of endothelium and simulated devices for studying particle performance under blood flow conditions. Finally, based on particle-endothelium interactions, we propose future opportunities for novel therapeutic strategies and provide solutions to challenges in particle delivery systems for accelerating their clinical translation. This review helps provoke an increasing in-depth understanding of particle-endothelium interactions and inspires more strategies that may benefit the development of particle medicine.
Collapse
Affiliation(s)
- Xiaotong Li
- School of Pharmacy, China Pharmaceutical University, Nanjing 2111198, PR China
| | - Jiahui Zou
- School of Pharmacy, China Pharmaceutical University, Nanjing 2111198, PR China
| | - Zhongshan He
- Department of Critical Care Medicine and Department of Biotherapy, Frontiers Science Center for Disease-related Molecular Network, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu 610000, PR China
| | - Yanhua Sun
- Shandong Provincial Key Laboratory of Microparticles Drug Delivery Technology, Qilu Pharmaceutical Co., LtD., Jinan 250000, PR China
| | - Xiangrong Song
- Department of Critical Care Medicine and Department of Biotherapy, Frontiers Science Center for Disease-related Molecular Network, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu 610000, PR China.
| | - Wei He
- School of Pharmacy, China Pharmaceutical University, Nanjing 2111198, PR China.
| |
Collapse
|
2
|
Rane A, Jarmoshti J, Siddique AB, Adair S, Torres-Castro K, Honrado C, Bauer TW, Swami NS. Dielectrophoretic enrichment of live chemo-resistant circulating-like pancreatic cancer cells from media of drug-treated adherent cultures of solid tumors. LAB ON A CHIP 2024; 24:561-571. [PMID: 38174422 PMCID: PMC10826460 DOI: 10.1039/d3lc00804e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 12/19/2023] [Indexed: 01/05/2024]
Abstract
Due to low numbers of circulating tumor cells (CTCs) in liquid biopsies, there is much interest in enrichment of alternative circulating-like mesenchymal cancer cell subpopulations from in vitro tumor cultures for utilization within molecular profiling and drug screening. Viable cancer cells that are released into the media of drug-treated adherent cancer cell cultures exhibit anoikis resistance or anchorage-independent survival away from their extracellular matrix with nutrient sources and waste sinks, which serves as a pre-requisite for metastasis. The enrichment of these cell subpopulations from tumor cultures can potentially serve as an in vitro source of circulating-like cancer cells with greater potential for scale-up in comparison with CTCs. However, these live circulating-like cancer cell subpopulations exhibit size overlaps with necrotic and apoptotic cells in the culture media, which makes it challenging to selectively enrich them, while maintaining them in their suspended state. We present optimization of a flowthrough high frequency (1 MHz) positive dielectrophoresis (pDEP) device with sequential 3D field non-uniformities that enables enrichment of the live chemo-resistant circulating cancer cell subpopulation from an in vitro culture of metastatic patient-derived pancreatic tumor cells. Central to this strategy is the utilization of single-cell impedance cytometry with gates set by supervised machine learning, to optimize the frequency for pDEP, so that live circulating cells are selected based on multiple biophysical metrics, including membrane physiology, cytoplasmic conductivity and cell size, which is not possible using deterministic lateral displacement that is solely based on cell size. Using typical drug-treated samples with low levels of live circulating cells (<3%), we present pDEP enrichment of the target subpopulation to ∼44% levels within 20 minutes, while rejecting >90% of dead cells. This strategy of utilizing single-cell impedance cytometry to guide the optimization of dielectrophoresis has implications for other complex biological samples.
Collapse
Affiliation(s)
- Aditya Rane
- Chemistry, University of Virginia, Charlottesville, USA.
| | - Javad Jarmoshti
- Electrical & Computer Engineering, University of Virginia, Charlottesville, USA
| | | | - Sara Adair
- Surgery, School of Medicine, University of Virginia, Charlottesville, USA
| | | | - Carlos Honrado
- International Iberian Nanotechnology Laboratory, Braga, Portugal
| | - Todd W Bauer
- Surgery, School of Medicine, University of Virginia, Charlottesville, USA
| | - Nathan S Swami
- Chemistry, University of Virginia, Charlottesville, USA.
- Electrical & Computer Engineering, University of Virginia, Charlottesville, USA
| |
Collapse
|
3
|
Yoon S, Kilicarslan You D, Jeong U, Lee M, Kim E, Jeon TJ, Kim SM. Microfluidics in High-Throughput Drug Screening: Organ-on-a-Chip and C. elegans-Based Innovations. BIOSENSORS 2024; 14:55. [PMID: 38275308 PMCID: PMC10813408 DOI: 10.3390/bios14010055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/16/2024] [Accepted: 01/19/2024] [Indexed: 01/27/2024]
Abstract
The development of therapeutic interventions for diseases necessitates a crucial step known as drug screening, wherein potential substances with medicinal properties are rigorously evaluated. This process has undergone a transformative evolution, driven by the imperative need for more efficient, rapid, and high-throughput screening platforms. Among these, microfluidic systems have emerged as the epitome of efficiency, enabling the screening of drug candidates with unprecedented speed and minimal sample consumption. This review paper explores the cutting-edge landscape of microfluidic-based drug screening platforms, with a specific emphasis on two pioneering approaches: organ-on-a-chip and C. elegans-based chips. Organ-on-a-chip technology harnesses human-derived cells to recreate the physiological functions of human organs, offering an invaluable tool for assessing drug efficacy and toxicity. In parallel, C. elegans-based chips, boasting up to 60% genetic homology with humans and a remarkable affinity for microfluidic systems, have proven to be robust models for drug screening. Our comprehensive review endeavors to provide readers with a profound understanding of the fundamental principles, advantages, and challenges associated with these innovative drug screening platforms. We delve into the latest breakthroughs and practical applications in this burgeoning field, illuminating the pivotal role these platforms play in expediting drug discovery and development. Furthermore, we engage in a forward-looking discussion to delineate the future directions and untapped potential inherent in these transformative technologies. Through this review, we aim to contribute to the collective knowledge base in the realm of drug screening, providing valuable insights to researchers, clinicians, and stakeholders alike. We invite readers to embark on a journey into the realm of microfluidic-based drug screening platforms, fostering a deeper appreciation for their significance and promising avenues yet to be explored.
Collapse
Affiliation(s)
- Sunhee Yoon
- Department of Biological Sciences and Bioengineering, Inha University, Incheon 22212, Republic of Korea; (S.Y.); (D.K.Y.); (M.L.); (E.K.)
| | - Dilara Kilicarslan You
- Department of Biological Sciences and Bioengineering, Inha University, Incheon 22212, Republic of Korea; (S.Y.); (D.K.Y.); (M.L.); (E.K.)
| | - Uiechan Jeong
- Department of Mechanical Engineering, Inha University, Incheon 22212, Republic of Korea
| | - Mina Lee
- Department of Biological Sciences and Bioengineering, Inha University, Incheon 22212, Republic of Korea; (S.Y.); (D.K.Y.); (M.L.); (E.K.)
| | - Eunhye Kim
- Department of Biological Sciences and Bioengineering, Inha University, Incheon 22212, Republic of Korea; (S.Y.); (D.K.Y.); (M.L.); (E.K.)
| | - Tae-Joon Jeon
- Department of Biological Sciences and Bioengineering, Inha University, Incheon 22212, Republic of Korea; (S.Y.); (D.K.Y.); (M.L.); (E.K.)
- Department of Biological Engineering, Inha University, Incheon 22212, Republic of Korea
- Biohybrid Systems Research Center (BSRC), Inha University, Incheon 22212, Republic of Korea
| | - Sun Min Kim
- Department of Biological Sciences and Bioengineering, Inha University, Incheon 22212, Republic of Korea; (S.Y.); (D.K.Y.); (M.L.); (E.K.)
- Department of Mechanical Engineering, Inha University, Incheon 22212, Republic of Korea
- Biohybrid Systems Research Center (BSRC), Inha University, Incheon 22212, Republic of Korea
| |
Collapse
|
4
|
N-octadecyl lactose-amide modified microemulsions as targeting delivery carrier for α-linolenic acid: In vitro evaluation and interaction mechanism. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.119876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
5
|
Akther F, Zhang J, Tran HDN, Fallahi H, Adelnia H, Phan HP, Nguyen NT, Ta HT. Atherothrombosis-on-Chip: A Site-Specific Microfluidic Model for Thrombus Formation and Drug Discovery. Adv Biol (Weinh) 2022; 6:e2101316. [PMID: 35666057 DOI: 10.1002/adbi.202101316] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 05/06/2022] [Indexed: 01/28/2023]
Abstract
Atherothrombosis, an atherosclerotic plaque disruption condition with superimposed thrombosis, is the underlying cause of cardiovascular episodes. Herein, a unique design is presented to develop a microfluidic site-specific atherothrombosis-on-chip model, providing a universal platform for studying the crosstalk between blood cells and plaque components. The device consists of two interconnected microchannels, namely main and supporting channels: the former mimics the vessel geometry with different stenosis, and the latter introduces plaque components to the circulation simultaneously. The unique design allows the site-specific introduction of plaque components in stenosed channels ranging from 0% to above 50%, resulting in thrombosis, which has not been achieved previously. The device successfully explains the correlation between vessel geometry and thrombus formation phenomenon as well as the influence of shear rate on platelet aggregation, confirming the reliability and the effectiveness of the design. The device exhibits significant sensitivity to aspirin. In therapeutic doses (50 × 10-6 and 100 × 10-6 m), aspirin delays and prevents platelet adhesion, thereby reducing the thrombus area in a dose-dependent manner. Finally, the device is effectively employed in testing the targeted binding of the RGD (arginyl-glycyl-aspartic acid) labeled polymeric nanoparticles on the thrombus, extending the use of the device to examine targeted drug carriers.
Collapse
Affiliation(s)
- Fahima Akther
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia.,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland, 4072, Australia
| | - Jun Zhang
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia
| | - Huong D N Tran
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia.,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland, 4072, Australia
| | - Hedieh Fallahi
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia
| | - Hossein Adelnia
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia.,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland, 4072, Australia
| | - Hoang-Phuong Phan
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia
| | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia
| | - Hang Thu Ta
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia.,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland, 4072, Australia.,School of Environment and Science, Griffith University, Nathan, Queensland, 4111, Australia
| |
Collapse
|
6
|
Tang D, Jiang L, Tang W, Xiang N, Ni Z. Cost-effective portable microfluidic impedance cytometer for broadband impedance cell analysis based on viscoelastic focusing. Talanta 2022; 242:123274. [DOI: 10.1016/j.talanta.2022.123274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 01/25/2022] [Accepted: 01/27/2022] [Indexed: 11/27/2022]
|
7
|
Li X, Yang Y, Villareal SC, Griffin K, Pappas D. High-recovery sorting of cancer cells from whole blood via periodic-focusing inertial microchip. Analyst 2022; 147:4536-4546. [DOI: 10.1039/d2an01310j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Inertial microfluidic devices continue to show promise for label-free separation of cells from liquid biopsies and other biological samples.
Collapse
Affiliation(s)
- Xiao Li
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, 79409, USA
| | - Yijia Yang
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, 79409, USA
| | - Sarah C. Villareal
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, 79409, USA
| | - Kitiara Griffin
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, 79409, USA
| | - Dimitri Pappas
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, 79409, USA
| |
Collapse
|
8
|
Zhou Z, Chen Y, Zhu S, Liu L, Ni Z, Xiang N. Inertial microfluidics for high-throughput cell analysis and detection: a review. Analyst 2021; 146:6064-6083. [PMID: 34490431 DOI: 10.1039/d1an00983d] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Since it was first proposed in 2007, inertial microfluidics has been extensively studied in terms of theory, design, fabrication, and application. In recent years, with the rapid development of microfabrication technologies, a variety of channel structures that can focus, concentrate, separate, and capture bioparticles or fluids have been designed and manufactured to extend the range of potential biomedical applications of inertial microfluidics. Due to the advantages of high throughput, simplicity, and low device cost, inertial microfluidics is a promising candidate for rapid sample processing, especially for large-volume samples with low-abundance targets. As an approach to cellular sample pretreatment, inertial microfluidics has been widely employed to ensure downstream cell analysis and detection. In this review, a comprehensive summary of the application of inertial microfluidics for high-throughput cell analysis and detection is presented. According to application areas, the recent advances can be sorted into label-free cell mechanical phenotyping, sheathless flow cytometric counting, electrical impedance cytometer, high-throughput cellular image analysis, and other methods. Finally, the challenges and prospects of inertial microfluidics for cell analysis and detection are summarized.
Collapse
Affiliation(s)
- Zheng Zhou
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Yao Chen
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Shu Zhu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Linbo Liu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| |
Collapse
|
9
|
Jiang D, Ni C, Tang W, Huang D, Xiang N. Inertial microfluidics in contraction-expansion microchannels: A review. BIOMICROFLUIDICS 2021; 15:041501. [PMID: 34262632 PMCID: PMC8254650 DOI: 10.1063/5.0058732] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 06/19/2021] [Indexed: 05/02/2023]
Abstract
Inertial microfluidics has brought enormous changes in the conventional cell/particle detection process and now become the main trend of sample pretreatment with outstanding throughput, low cost, and simple control method. However, inertial microfluidics in a straight microchannel is not enough to provide high efficiency and satisfying performance for cell/particle separation. A contraction-expansion microchannel is a widely used and multifunctional channel pattern involving inertial microfluidics, secondary flow, and the vortex in the chamber. The strengthened inertial microfluidics can help us to focus particles with a shorter channel length and less processing time. Both the vortex in the chamber and the secondary flow in the main channel can trap the target particles or separate particles based on their sizes more precisely. The contraction-expansion microchannels are also capable of combining with a curved, spiral, or serpentine channel to further improve the separation performance. Some recent studies have focused on the viscoelastic fluid that utilizes both elastic forces and inertial forces to separate different size particles precisely with a relatively low flow rate for the vulnerable cells. This article comprehensively reviews various contraction-expansion microchannels with Newtonian and viscoelastic fluids for particle focusing, separation, and microfluid mixing and provides particle manipulation performance data analysis for the contraction-expansion microchannel design.
Collapse
Affiliation(s)
- Di Jiang
- Author to whom correspondence should be addressed:
| | - Chen Ni
- College of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing 210037, China
| | | | - Di Huang
- School of Mechatronic Engineering, China University of Mining and Technology, Xuzhou 221116, China
| | - Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, China
| |
Collapse
|
10
|
Shen S, Wang X, Niu Y. Multi-Vortex Regulation for Efficient Fluid and Particle Manipulation in Ultra-Low Aspect Ratio Curved Microchannels. MICROMACHINES 2021; 12:mi12070758. [PMID: 34199145 PMCID: PMC8303296 DOI: 10.3390/mi12070758] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Revised: 06/02/2021] [Accepted: 06/23/2021] [Indexed: 01/02/2023]
Abstract
Inertial microfluidics enables fluid and particle manipulation for biomedical and clinical applications. Herein, we developed a simple semicircular microchannel with an ultra-low aspect ratio to interrogate the unique formations of the helical vortex and Dean vortex by introducing order micro-obstacles. The purposeful and powerful regulation of dimensional confinement in the microchannel achieved significantly improved fluid mixing effects and fluid and particle manipulation in a high-throughput, highly efficient and easy-to-use way. Together, the results offer insights into the geometry-induced multi-vortex mechanism, which may contribute to simple, passive, continuous operations for biochemical and clinical applications, such as the detection and isolation of circulating tumor cells for cancer diagnostics.
Collapse
Affiliation(s)
- Shaofei Shen
- Correspondence: (S.S.); (Y.N.); Tel./Fax: +86-354-6287205 (S.S. & Y.N.)
| | | | - Yanbing Niu
- Correspondence: (S.S.); (Y.N.); Tel./Fax: +86-354-6287205 (S.S. & Y.N.)
| |
Collapse
|
11
|
Lu Y, Tan W, Shi X, Liu M, Zhu G. A weak shear stress microfluidic device based on Viscoelastic Stagnant Region (VSR) for biosensitive particle capture. Talanta 2021; 233:122550. [PMID: 34215053 DOI: 10.1016/j.talanta.2021.122550] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 05/06/2021] [Accepted: 05/11/2021] [Indexed: 01/29/2023]
Abstract
Particle manipulation in microfluidic devices is of great significance in biological research. However, currently available inertial capture methods require relatively high flow rates, which will cause damage to biological particles, especially for single-celled organisms that are sensitive to environments. Herein, we demonstrate a label-free, size-based, low shear stress manipulation method using the Viscoelastic Stagnant Region (VSR) to capture sensitive bioparticles. This method uses the deformation of molecular chains in the polymer solution which can generate elastic stresses to form vortices which is called VSR because of the extremely low velocity in the contraction-expansion array (CEA) microchannel. Formation and evolution of VSR was observed experimentally using the Micro-PIV system in polyethylene oxide (PEO) solutions with different concentrations. On this basis, 20 μm and 5 μm polystyrene (PS) particles were confined to a certain area in the microchamber and the trajectory of particles motion in VSR was observed. Both the inertial lift force and the viscoelastic force are affected by the particle size, so the method also presented size selectivity. By quantitatively studying the velocity distribution of the particles on the orbit of motion, it was found that the maximum velocity of the particles in the VSR was about 0.02 m s-1, which is only about 1/100 of that in inertial vortices. Moreover, the spiral motion of particles captured by VSR with variable trajectories was first observed, which is different from the equilibrium orbit in inertial vortices and can provide more motion paths for the particles. This method was further applied to the research of Crypthecodinium cohnii (C. cohnii), which is vulnerable but has high nutritious value. We found that the activity of the C. cohnii decreased slightly after being processed by VSR, but was lost after being processed by the inertial vortices. This research, as a simple and low shear stress particle manipulation method, will provide useful guidance for the manipulation, capture and separation of sensitive biological cells under higher biocompatibility, which is of great significance for the study of cellular and molecular biology.
Collapse
Affiliation(s)
- Yuwen Lu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300350, China
| | - Wei Tan
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300350, China
| | - Xin Shi
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300350, China
| | - Mingwei Liu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300350, China
| | - Guorui Zhu
- School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300350, China.
| |
Collapse
|
12
|
Rodriguez-Mateos P, Ngamsom B, Dyer CE, Iles A, Pamme N. Inertial focusing of microparticles, bacteria, and blood in serpentine glass channels. Electrophoresis 2021; 42:2246-2255. [PMID: 34031893 DOI: 10.1002/elps.202100083] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 05/11/2021] [Accepted: 05/18/2021] [Indexed: 11/08/2022]
Abstract
Early detection of pathogenic microorganisms is pivotal to diagnosis and prevention of health and safety crises. Standard methods for pathogen detection often rely on lengthy culturing procedures, confirmed by biochemical assays, leading to >24 h for a diagnosis. The main challenge for pathogen detection is their low concentration within complex matrices. Detection of blood-borne pathogens via techniques such as PCR requires an initial positive blood culture and removal of inhibitory blood components, reducing its potential as a diagnostic tool. Among different label-free microfluidic techniques, inertial focusing on microscale channels holds great promise for automation, parallelization, and passive continuous separation of particles and cells. This work presents inertial microfluidic manipulation of small particles and cells (1-10 μm) in curved serpentine glass channels etched at different depths (deep and shallow designs) that can be exploited for (1) bacteria preconcentration from biological samples and (2) bacteria-blood cell separation. In our shallow device, the ability to focus Escherichia coli into the channel side streams with high recovery (89% at 2.2× preconcentration factor) could be applied for bacteria preconcentration in urine for diagnosis of urinary tract infections. Relying on differential equilibrium positions of red blood cells and E. coli inside the deep device, 97% red blood cells were depleted from 1:50 diluted blood with 54% E. coli recovered at a throughput of 0.7 mL/min. Parallelization of such devices could process relevant volumes of 7 mL whole blood in 10 min, allowing faster sample preparation for downstream molecular diagnostics of bacteria present in bloodstream.
Collapse
Affiliation(s)
| | - Bongkot Ngamsom
- Department of Chemistry and Biochemistry, University of Hull, Hull, UK
| | | | - Alexander Iles
- Department of Chemistry and Biochemistry, University of Hull, Hull, UK
| | - Nicole Pamme
- Department of Chemistry and Biochemistry, University of Hull, Hull, UK
| |
Collapse
|
13
|
Wang S, Liu Z, Wu S, Sun H, Zeng W, Wei J, Fan Z, Sui Z, Liu L, Pan X. Microalgae separation by inertia-enhanced pinched flow fractionation. Electrophoresis 2021; 42:2223-2229. [PMID: 33938005 DOI: 10.1002/elps.202000325] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Revised: 04/02/2021] [Accepted: 04/20/2021] [Indexed: 11/10/2022]
Abstract
To improve the accuracy and efficiency of ships' ballast water detection, the separation of microalgae according to size is significant. In this article, a method to separate microalgae based on inertia-enhanced pinched flow fractionation (iPFF) was reported. The method utilized the inertial lift force induced by flow to separate microalgae according to size continuously. The experimental results show that, as the Reynolds number increases, the separation effect becomes better at first, but then stays unchanged. The best separation effect can be obtained when the Reynolds number is 12.3. In addition, with the increase of the flow rate ratio between sheath fluid and microalgae mixture, the separation effect becomes better and the best separation effect can be obtained when the flow rate ratio reaches 10. In this case, the recovery rate of Tetraselmis sp. is about 90%, and the purity is about 86%; the recovery rate of Chlorella sp. is as high as 99%, and the purity is about 99%. After that, the separation effect keeps getting better but very slowly. In general, this study provides a simple method for the separation of microalgae with different sizes, and lays a foundation for the accurate detection of microalgae in the ballast water.
Collapse
Affiliation(s)
- Saijie Wang
- School of Science, Dalian Maritime University, Dalian, P. R. China
| | - Zhijian Liu
- College of Marine Engineering, Dalian Maritime University, Dalian, P. R. China
| | - Sen Wu
- College of Marine Engineering, Dalian Maritime University, Dalian, P. R. China
| | - Hongyan Sun
- School of Maritime Economics and Management, Dalian Maritime University, Dalian, P. R. China
| | - Wu Zeng
- College of Marine Engineering, Dalian Maritime University, Dalian, P. R. China
| | - Jintao Wei
- Maritime College, Dalian Maritime University, Dalian, P. R. China
| | - Zixiao Fan
- College of Marine Engineering, Dalian Maritime University, Dalian, P. R. China
| | - Zhuohang Sui
- College of Marine Engineering, Dalian Maritime University, Dalian, P. R. China
| | - Liankun Liu
- College of Marine Engineering, Dalian Maritime University, Dalian, P. R. China
| | - Xinxiang Pan
- College of Marine Engineering, Dalian Maritime University, Dalian, P. R. China.,College of Navigation, Guangdong Ocean University, Zhanjiang, P. R. China
| |
Collapse
|
14
|
Crowell LL, Yakisich JS, Aufderheide B, Adams TNG. Electrical Impedance Spectroscopy for Monitoring Chemoresistance of Cancer Cells. MICROMACHINES 2020; 11:E832. [PMID: 32878225 PMCID: PMC7570252 DOI: 10.3390/mi11090832] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/28/2020] [Accepted: 08/29/2020] [Indexed: 12/14/2022]
Abstract
Electrical impedance spectroscopy (EIS) is an electrokinetic method that allows for the characterization of intrinsic dielectric properties of cells. EIS has emerged in the last decade as a promising method for the characterization of cancerous cells, providing information on inductance, capacitance, and impedance of cells. The individual cell behavior can be quantified using its characteristic phase angle, amplitude, and frequency measurements obtained by fitting the input frequency-dependent cellular response to a resistor-capacitor circuit model. These electrical properties will provide important information about unique biomarkers related to the behavior of these cancerous cells, especially monitoring their chemoresistivity and sensitivity to chemotherapeutics. There are currently few methods to assess drug resistant cancer cells, and therefore it is difficult to identify and eliminate drug-resistant cancer cells found in static and metastatic tumors. Establishing techniques for the real-time monitoring of changes in cancer cell phenotypes is, therefore, important for understanding cancer cell dynamics and their plastic properties. EIS can be used to monitor these changes. In this review, we will cover the theory behind EIS, other impedance techniques, and how EIS can be used to monitor cell behavior and phenotype changes within cancerous cells.
Collapse
Affiliation(s)
- Lexi L. Crowell
- Department of Chemical and Biomolecular Engineering, University of California-Irvine, Irvine, CA 92697, USA;
- Sue & Bill Gross Stem Cell Research Center, University of California Irvine, Irvine, CA 92697, USA
| | - Juan S. Yakisich
- Department of Pharmaceutical Sciences, Hampton University, Hampton, VA 23668, USA;
| | - Brian Aufderheide
- Department of Chemical Engineering, Hampton University, Hampton, VA 23668, USA;
| | - Tayloria N. G. Adams
- Department of Chemical and Biomolecular Engineering, University of California-Irvine, Irvine, CA 92697, USA;
- Sue & Bill Gross Stem Cell Research Center, University of California Irvine, Irvine, CA 92697, USA
| |
Collapse
|