1
|
Du Z, Xu Q, Xi Y, Xu M, Cao J, Wang L, Li X, Wang X, Liu Q, Lin Z, Yang B, Liu J. Controllable tip exposure of ultramicroelectrodes coated by diamond-like carbon via direct microplasma jet for enhanced stability and fidelity in single-cell recording. MICROSYSTEMS & NANOENGINEERING 2025; 11:20. [PMID: 39843507 PMCID: PMC11754621 DOI: 10.1038/s41378-024-00819-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 08/09/2024] [Accepted: 08/26/2024] [Indexed: 01/24/2025]
Abstract
Precise and long-term electroanalysis at the single-cell level is crucial for the accurate diagnosis and monitoring of brain diseases. The reliable protection in areas outside the signal acquisition points at sharp ultramicroelectrode (UME) tips has a significant impact on the sensitivity, fidelity, and stability of intracellular neural signal recording. However, it is difficult for existing UMEs to achieve controllable exposure of the tip functional structure, which affects their ability to resist environmental interference and shield noise, resulting in unsatisfactory signal-to-noise ratio and signal fidelity of intracellular recordings. To address this issue, we chose a dense and electrochemically stable diamond-like carbon (DLC) film as the UME protection coating and developed a method to precisely control the exposed degree of the functional structure by directly fixed-point processing of the UME tip by the strong site-selectivity and good controllability of the atmospheric microplasma jet. By analyzing the interaction between the microplasma jet and the UME tip, as well as the changes in the removal length and microstructure of UME tips with processing time, the exposed tip length was precisely controlled down to the submicron scale. Biocompatibility experiments, electrochemical aging tests and real-time intracellular pH recording experiments have demonstrated that the DLC-UME with effective tip protection processed by microplasma jet has the potential to enable long-term detection of intracellular high-fidelity signals.
Collapse
Affiliation(s)
- Zhiyuan Du
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
- DCI Joint Team, Collaborative Innovation Center of IFSA, Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, China
| | - Qingda Xu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
- DCI Joint Team, Collaborative Innovation Center of IFSA, Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, China
| | - Ye Xi
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
- DCI Joint Team, Collaborative Innovation Center of IFSA, Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, China
| | - Mengfei Xu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
- DCI Joint Team, Collaborative Innovation Center of IFSA, Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, China
| | - Jiawei Cao
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
- DCI Joint Team, Collaborative Innovation Center of IFSA, Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, China
| | - Longchun Wang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
| | - Xiuyan Li
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
| | - Xiaolin Wang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
| | - Qingkun Liu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
| | - Zude Lin
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
| | - Bin Yang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
| | - Jingquan Liu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
2
|
Wen MY, Qi YT, Jiao YT, Zhang XW, Huang WH. Reference-Attached pH Nanosensor for Accurately Monitoring the Rapid Kinetics of Intracellular H + Oscillations. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2025; 21:e2406796. [PMID: 39573856 DOI: 10.1002/smll.202406796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2024] [Indexed: 01/23/2025]
Abstract
Intracellular pH (pHi) is an essential indicator of cellular metabolic activity, as its transient or small shift can significantly impact cellular homeostasis and reflect the cellular events. Real-time and precise tracking of these rapid pH changes within a single living cell is therefore important. However, achieving high dynamic response performance (subsecond) pH detection inside a living cell with high accuracy remains a challenge. Here a reference-attached pH nanosensor (R-pH-nanosensor) with fast and precise pHi sensing performance is introduced. The nanosensor comprises a highly conductive H+-sensitive IrRuOx nanowire (SiC@IrRuOx NW) as the intracellular working electrode and a SiC@Ag/AgCl NW as an intracellular reference electrode (RE) to diminish the interferences arising from cell membrane potential fluctuations. This whole-inside-cell detection mode ensures that the entire potential detection circuit is located within the same cell, and the R-pH-nanosensor is able to quantify the mild acidification of cytosol and completely record the fast pH variation within a single cell. It also enables real-time potentiometric monitoring of the pHi oscillations, which synchronize with the glycolysis oscillations in cancer cells. Furthermore, the asymmetry in glycolysis oscillations wave is disclosed and the inhibitory effect of just lactate to glycolysis oscillations is further confirmed.
Collapse
Affiliation(s)
- Ming-Yong Wen
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Yu-Ting Qi
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Yu-Ting Jiao
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Xin-Wei Zhang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Wei-Hua Huang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
- Department of Hepatobiliary and Pancreatic Surgery, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China
| |
Collapse
|
3
|
Li Y, Zhang Y, Wang X, Zhu Y, Yuan J, Ren L, Chen J, Wang Z. A novel electrochemical membrane filtration system operated with periodical polarity reversal for efficient resource recovery from nickel nitrate laden industrial wastewater. WATER RESEARCH 2024; 266:122424. [PMID: 39293309 DOI: 10.1016/j.watres.2024.122424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2024] [Revised: 09/05/2024] [Accepted: 09/08/2024] [Indexed: 09/20/2024]
Abstract
The economical and efficient removal of nickel nitrate from industrial wastewater remains a challenge. Herein, we developed an innovative electrochemical membrane filtration system that used a periodic polarity reversal process to adjust the acid-base environment near membrane interface for the recovery of nickel (II) and ammonia. The Ru based electrocatalytic layer could boost the selective reduction of nitrate to ammonia by generating atomic hydrogen, resulting in the precipitation of Ni2+ by the increasing pH at the membrane interface. Then, the precipitation of Ni(OH)2 could be effectively stripped and collected under the periodic polarity reversal process. In-situ interfacial measurements demonstrated that the polarity reversal process enabled a reversible transformation between strongly acidic (pH < 2) and alkaline (pH > 13) environments within a 200 µm range at the membrane interface. In continuous flow operation treating real industrial wastewater containing 96.7 mg-N L-1 nitrate and 135.0 mg L-1 Ni2+, the system demonstrated the capability to achieve 92.5 ± 2.6 % nitrate removal (with a recovery efficiency of 15.1 ± 1.9 g-NH3 kWh-1) and 99.7 ± 0.1 % Ni²⁺ removal (with a recovery efficiency of 24.9 ± 2.4 g-Ni kWh-1). Additionally, the specific treatment cost was approximately $0.17 m-3, attributed to the recovery of Ni(OH)₂ and ammonia. Furthermore, this system could deliver a significant economic benefit ($1.64 per m3) for treating a high concentration real wastewater (331.5 mg-N L-1 nitrate and 1496.3 mg L-1 Ni2+), outperforming traditional alkali precipitation and biological nitrification/denitrification processes. Overall, our study presents an economical and sustainable method for recovering valuable chemicals from wastewater containing heavy metals and inorganic nitrogen, potentially advancing cost-effective water treatment technologies.
Collapse
Affiliation(s)
- Yang Li
- State Key Laboratory of Pollution Control and Resource Reuse, Shanghai Institute of Pollution Control and Ecological Security, Key Laboratory of Yangtze River Water Environment of Ministry of Education, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China; Tongji Advanced Membrane Technology Center, Shanghai 200092, China
| | - Yichi Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, Shanghai Institute of Pollution Control and Ecological Security, Key Laboratory of Yangtze River Water Environment of Ministry of Education, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China; Tongji Advanced Membrane Technology Center, Shanghai 200092, China
| | - Xueye Wang
- State Key Laboratory of Pollution Control and Resource Reuse, Shanghai Institute of Pollution Control and Ecological Security, Key Laboratory of Yangtze River Water Environment of Ministry of Education, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China; Tongji Advanced Membrane Technology Center, Shanghai 200092, China
| | - Yuting Zhu
- Tongji Architectural Design (Group) Co., Ltd., Shanghai 200092, China
| | - Jia Yuan
- State Key Laboratory of Pollution Control and Resource Reuse, Shanghai Institute of Pollution Control and Ecological Security, Key Laboratory of Yangtze River Water Environment of Ministry of Education, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China; Tongji Advanced Membrane Technology Center, Shanghai 200092, China
| | - Lehui Ren
- State Key Laboratory of Pollution Control and Resource Reuse, Shanghai Institute of Pollution Control and Ecological Security, Key Laboratory of Yangtze River Water Environment of Ministry of Education, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China; Tongji Advanced Membrane Technology Center, Shanghai 200092, China
| | - Jiansuxuan Chen
- State Key Laboratory of Pollution Control and Resource Reuse, Shanghai Institute of Pollution Control and Ecological Security, Key Laboratory of Yangtze River Water Environment of Ministry of Education, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China; Tongji Advanced Membrane Technology Center, Shanghai 200092, China
| | - Zhiwei Wang
- State Key Laboratory of Pollution Control and Resource Reuse, Shanghai Institute of Pollution Control and Ecological Security, Key Laboratory of Yangtze River Water Environment of Ministry of Education, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China; Tongji Advanced Membrane Technology Center, Shanghai 200092, China.
| |
Collapse
|
4
|
Xu Q, Xi Y, Wang L, Xu M, Ruan T, Du Z, Jiang C, Cao J, Zhu X, Wang X, Yang B, Liu J. In situ self-referenced intracellular two-electrode system for enhanced accuracy in single-cell analysis. Biosens Bioelectron 2024; 253:116173. [PMID: 38432075 DOI: 10.1016/j.bios.2024.116173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 02/19/2024] [Accepted: 02/26/2024] [Indexed: 03/05/2024]
Abstract
Since the emergence of single-cell electroanalysis, the two-electrode system has become the predominant electrochemical system for real-time behavioral analysis of single-cell and multicellular populations. However, due to the transmembrane placement of the two electrodes, cellular activities can be interrupted by the transmembrane potentials, and the test results are susceptible to influences from factors such as intracellular solution, membrane, and bulk solution. These limitations impede the advancement of single-cell analysis. Here, we propose a highly miniaturized and integrated in situ self-referenced intracellular two-electrode system (IS-SRITES), wherein both the working and reference electrodes are positioned inside the cell. Additionally, we demonstrated the stability (0.28 mV/h) of the solid-contact in situ Ag/AgCl reference electrode and the ability of the system to conduct standard electrochemical testing in a wide pH range (pH 6.0-8.0). Cell experiments confirmed the non-destructive performance of the electrode system towards cells and its capacity for real-time monitoring of intra- and extracellular pH values. Moreover, through equivalent circuits, finite element simulations, and drug delivery experiments, we illustrated that the IS-SRITES can yield more accurate test results and exhibit enhanced resistance to interference from the extracellular environment. Our proposed system holds the potential to enable the precise detection of intracellular substances and optimize the existing model of the electrode system for intracellular signal detection, thereby spearheading advancements in single-cell analysis.
Collapse
Affiliation(s)
- Qingda Xu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Ye Xi
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Longchun Wang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Mengfei Xu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Tao Ruan
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Zhiyuan Du
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Chunpeng Jiang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Jiawei Cao
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Xiantao Zhu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China; Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Xiaolin Wang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Bin Yang
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Jingquan Liu
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China.
| |
Collapse
|
5
|
Troncoso-Afonso L, Vinnacombe-Willson GA, García-Astrain C, Liz-Márzan LM. SERS in 3D cell models: a powerful tool in cancer research. Chem Soc Rev 2024; 53:5118-5148. [PMID: 38607302 PMCID: PMC11104264 DOI: 10.1039/d3cs01049j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Indexed: 04/13/2024]
Abstract
Unraveling the cellular and molecular mechanisms underlying tumoral processes is fundamental for the diagnosis and treatment of cancer. In this regard, three-dimensional (3D) cancer cell models more realistically mimic tumors compared to conventional 2D cell cultures and are more attractive for performing such studies. Nonetheless, the analysis of such architectures is challenging because most available techniques are destructive, resulting in the loss of biochemical information. On the contrary, surface-enhanced Raman spectroscopy (SERS) is a non-invasive analytical tool that can record the structural fingerprint of molecules present in complex biological environments. The implementation of SERS in 3D cancer models can be leveraged to track therapeutics, the production of cancer-related metabolites, different signaling and communication pathways, and to image the different cellular components and structural features. In this review, we highlight recent progress in the use of SERS for the evaluation of cancer diagnosis and therapy in 3D tumoral models. We outline strategies for the delivery and design of SERS tags and shed light on the possibilities this technique offers for studying different cellular processes, through either biosensing or bioimaging modalities. Finally, we address current challenges and future directions, such as overcoming the limitations of SERS and the need for the development of user-friendly and robust data analysis methods. Continued development of SERS 3D bioimaging and biosensing systems, techniques, and analytical strategies, can provide significant contributions for early disease detection, novel cancer therapies, and the realization of patient-tailored medicine.
Collapse
Affiliation(s)
- Lara Troncoso-Afonso
- BioNanoPlasmonics Laboratory, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), 20014 Donostia-San Sebastián, Spain.
- Department of Applied Chemistry, University of the Basque Country, 20018 Donostia-San Sebastián, Gipuzkoa, Spain
| | - Gail A Vinnacombe-Willson
- BioNanoPlasmonics Laboratory, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), 20014 Donostia-San Sebastián, Spain.
| | - Clara García-Astrain
- BioNanoPlasmonics Laboratory, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), 20014 Donostia-San Sebastián, Spain.
- Centro de Investigación Biomédica en Red de Bioingeniería Biomateriales, y Nanomedicina (CIBER-BBN), Paseo de Miramón 182, 20014 Donostia-San Sebastián, Spain
| | - Luis M Liz-Márzan
- BioNanoPlasmonics Laboratory, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), 20014 Donostia-San Sebastián, Spain.
- Centro de Investigación Biomédica en Red de Bioingeniería Biomateriales, y Nanomedicina (CIBER-BBN), Paseo de Miramón 182, 20014 Donostia-San Sebastián, Spain
- Ikerbasque Basque Foundation for Science, 48013 Bilbao, Spain
| |
Collapse
|
6
|
Li Y, Zhu X, Ding J, Qin W. Robust Potentiometric Microelectrodes for In Situ Sensing of Ion Fluxes with High Sensitivity. Anal Chem 2023; 95:18754-18759. [PMID: 37989258 DOI: 10.1021/acs.analchem.3c03267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
Simple, reproducible, and reliable preparation of robust potentiometric microelectrodes is both challenging and of great importance for noninvasive real-time ion sensing. Herein, we report a simple strategy for the large-scale synthesis of nickel cobalt sulfide (NiCo2S4) nanowire arrays grown on carbon fibers for potentiometric microelectrodes. The highly uniform NiCo2S4 nanowire array serving as a transduction layer can provide a high capillary pressure and viscous resistance for loading the ion sensing membrane and exhibit a large redox capacitance for improving the stability. An all-solid-state lead-selective microelectrode, which presents a detection limit of 2.5 × 10-8 M in the simulated soil solution, was designed as a model for noninvasive, in situ, and real-time detection of ion fluxes near the rice root surface. Importantly, the microsensor enables sensitive detection of trace-level ion-fluxes. This work provides a simple yet general strategy for designing potentiometric microelectrodes.
Collapse
Affiliation(s)
- Yanhong Li
- Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China
- College of Chemistry and Chemical Engineering, Yantai University, Yantai, Shandong 264005, P. R. China
| | - Xu Zhu
- School of Materials Science and Engineering, China University of Petroleum, Qingdao, Shandong 266580, P. R. China
| | - Jiawang Ding
- Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China
| | - Wei Qin
- Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China
- Laboratory for Marine Biology and Biotechnology, Qingdao National Laboratory for Marine Science and Technology, Qingdao, Shandong 266237, P. R. China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, Shandong 266071, P. R. China
| |
Collapse
|
7
|
Kim M, Chen C, Yaari Z, Frederiksen R, Randall E, Wollowitz J, Cupo C, Wu X, Shah J, Worroll D, Lagenbacher RE, Goerzen D, Li YM, An H, Wang Y, Heller DA. Nanosensor-based monitoring of autophagy-associated lysosomal acidification in vivo. Nat Chem Biol 2023; 19:1448-1457. [PMID: 37322156 PMCID: PMC10721723 DOI: 10.1038/s41589-023-01364-9] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Accepted: 05/12/2023] [Indexed: 06/17/2023]
Abstract
Autophagy is a cellular process with important functions that drive neurodegenerative diseases and cancers. Lysosomal hyperacidification is a hallmark of autophagy. Lysosomal pH is currently measured by fluorescent probes in cell culture, but existing methods do not allow for quantitative, transient or in vivo measurements. In the present study, we developed near-infrared optical nanosensors using organic color centers (covalent sp3 defects on carbon nanotubes) to measure autophagy-mediated endolysosomal hyperacidification in live cells and in vivo. The nanosensors localize to the lysosomes, where the emission band shifts in response to local pH, enabling spatial, dynamic and quantitative mapping of subtle changes in lysosomal pH. Using the sensor, we observed cellular and intratumoral hyperacidification on administration of mTORC1 and V-ATPase modulators, revealing that lysosomal acidification mirrors the dynamics of S6K dephosphorylation and LC3B lipidation while diverging from p62 degradation. This sensor enables the transient and in vivo monitoring of the autophagy-lysosomal pathway.
Collapse
Affiliation(s)
- Mijin Kim
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Chen Chen
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Weill Cornell Medicine, Cornell University, New York, NY, USA
- Tri-Institutional PhD Program in Chemical Biology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Zvi Yaari
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
- School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem, Israel
| | | | | | - Jaina Wollowitz
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Weill Cornell Medicine, Cornell University, New York, NY, USA
- Tri-Institutional PhD Program in Chemical Biology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Christian Cupo
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Xiaojian Wu
- Department of Chemistry and Biochemistry, University of Maryland, College Park, MD, USA
| | - Janki Shah
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Daniel Worroll
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Rachel E Lagenbacher
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Weill Cornell Medicine, Cornell University, New York, NY, USA
| | - Dana Goerzen
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Weill Cornell Medicine, Cornell University, New York, NY, USA
| | - Yue-Ming Li
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Weill Cornell Medicine, Cornell University, New York, NY, USA
| | - Heeseon An
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Weill Cornell Medicine, Cornell University, New York, NY, USA
| | - YuHuang Wang
- Department of Chemistry and Biochemistry, University of Maryland, College Park, MD, USA
- Maryland NanoCenter, University of Maryland, College Park, MD, USA
| | - Daniel A Heller
- Memorial Sloan Kettering Cancer Center, New York, NY, USA.
- Weill Cornell Medicine, Cornell University, New York, NY, USA.
| |
Collapse
|
8
|
Ghosh S, Lai JY. Recent advances in the design of intracellular pH sensing nanoprobes based on organic and inorganic materials. ENVIRONMENTAL RESEARCH 2023; 237:117089. [PMID: 37683789 DOI: 10.1016/j.envres.2023.117089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 08/16/2023] [Accepted: 09/05/2023] [Indexed: 09/10/2023]
Abstract
In the biological system, the intracellular pH (pHi) plays an important role in regulating diverse physiological activities, including enzymatic action, ion transport, cell proliferation, metabolism, and programmed cell death. The monitoring of pH inside living cells is also crucial for studying cellular events such as phagocytosis, endocytosis, and receptor-ligand internalization. Furthermore, some organelles, viz., endosomes and lysosomes, have intracompartmental pH, which is critical for maintaining the stability of protein structure and function. The dysfunction and abnormal pH regulation can result in terminal diseases such as cancer, Alzheimer, and so forth. Therefore, the accuracy of intracellular pH measurement is always the top priority and demands cutting-edge research and analysis. Such techniques, such as Raman spectroscopy and fluorescence imaging, preferably use nanotechnology due to their remarkable advantages, such as a non-invasive approach and providing accuracy, repeatability, and reproducibility. In the past decades, there have been numerous attempts to design and construct non-invasive organic and inorganic materials-based nanoprobes for pHi sensing. For Raman-based techniques, metal nanostructures such as Au/Ag/Cu nanoparticles are utilized to enhance the signal intensity. As for the fluorescence-based studies, the organic-based small molecules, such as dyes, show higher sensitivity toward pH. However, they possess several drawbacks, including high photobleaching rate, and autofluorescence background signals. To this end, there are alternative nanomaterials proposed, including semiconductor quantum dots (QDs), carbon QDs, upconversion nanoparticles, and so forth. Moreover, the fluorescence technique allows for ratiometric measurement of pHi, which as a result, offers a reliable calibration curve. This timely review will critically examine the current progression in the existing nanoprobes. In addition, based on our knowledge and available research findings, we provide a brief future outlook that may advance the state-of-the-art methodologies for pHi sensing.
Collapse
Affiliation(s)
- Sandip Ghosh
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, 33302, Taiwan
| | - Jui-Yang Lai
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, 33302, Taiwan; Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taoyuan, 33305, Taiwan; Department of Materials Engineering, Ming Chi University of Technology, New Taipei City, 24301, Taiwan; Research Center for Chinese Herbal Medicine, College of Human Ecology, Chang Gung University of Science and Technology, Taoyuan, 33303, Taiwan.
| |
Collapse
|
9
|
Nur-E-Alam M, Maurya DK, Yap BK, Rajabi A, Doroody C, Bin Mohamed H, Khandaker MU, Islam MA, Kiong Tiong S. Physical-Vapor-Deposited Metal Oxide Thin Films for pH Sensing Applications: Last Decade of Research Progress. SENSORS (BASEL, SWITZERLAND) 2023; 23:8194. [PMID: 37837022 PMCID: PMC10575361 DOI: 10.3390/s23198194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 09/22/2023] [Accepted: 09/27/2023] [Indexed: 10/15/2023]
Abstract
In the last several decades, metal oxide thin films have attracted significant attention for the development of various existing and emerging technological applications, including pH sensors. The mandate for consistent and precise pH sensing techniques has been increasing across various fields, including environmental monitoring, biotechnology, food and agricultural industries, and medical diagnostics. Metal oxide thin films grown using physical vapor deposition (PVD) with precise control over film thickness, composition, and morphology are beneficial for pH sensing applications such as enhancing pH sensitivity and stability, quicker response, repeatability, and compatibility with miniaturization. Various PVD techniques, including sputtering, evaporation, and ion beam deposition, used to fabricate thin films for tailoring materials' properties for the advanced design and development of high-performing pH sensors, have been explored worldwide by many research groups. In addition, various thin film materials have also been investigated, including metal oxides, nitrides, and nanostructured films, to make very robust pH sensing electrodes with higher pH sensing performance. The development of novel materials and structures has enabled higher sensitivity, improved selectivity, and enhanced durability in harsh pH environments. The last decade has witnessed significant advancements in PVD thin films for pH sensing applications. The combination of precise film deposition techniques, novel materials, and surface functionalization strategies has led to improved pH sensing performance, making PVD thin films a promising choice for future pH sensing technologies.
Collapse
Affiliation(s)
- Mohammad Nur-E-Alam
- Institute of Sustainable Energy, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia; (B.K.Y.); (A.R.); (C.D.); (H.B.M.); (S.K.T.)
- School of Science, Edith Cowan University, 270 Joondalup Drive, Joondalup, WA 6027, Australia
- School of Engineering and Technology, Central Queensland University Australia, Melbourne, VIC 3000, Australia
| | - Devendra Kumar Maurya
- National Centre for Flexible Electronics, Indian Institute of Technology Kanpur, Kanpur 208016, India;
| | - Boon Kar Yap
- Institute of Sustainable Energy, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia; (B.K.Y.); (A.R.); (C.D.); (H.B.M.); (S.K.T.)
- College of Engineering, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia
| | - Armin Rajabi
- Institute of Sustainable Energy, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia; (B.K.Y.); (A.R.); (C.D.); (H.B.M.); (S.K.T.)
| | - Camellia Doroody
- Institute of Sustainable Energy, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia; (B.K.Y.); (A.R.); (C.D.); (H.B.M.); (S.K.T.)
- College of Engineering, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia
| | - Hassan Bin Mohamed
- Institute of Sustainable Energy, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia; (B.K.Y.); (A.R.); (C.D.); (H.B.M.); (S.K.T.)
- College of Engineering, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia
| | - Mayeen Uddin Khandaker
- Centre for Applied Physics and Radiation Technologies, School of Engineering and Technology, Sunway University, Bandar Sunway 47500, Selangor, Malaysia;
| | - Mohammad Aminul Islam
- Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Selangor, Malaysia;
| | - Sieh Kiong Tiong
- Institute of Sustainable Energy, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia; (B.K.Y.); (A.R.); (C.D.); (H.B.M.); (S.K.T.)
- College of Engineering, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, Kajang 43000, Selangor, Malaysia
| |
Collapse
|
10
|
Janasik D, Imielska P, Krawczyk T. Tuning the pH of Activation of Fluorinated Hydrazone-Based Switches─A Pathway to Versatile 19F Magnetic Resonance Imaging Contrast Agents. ACS Sens 2023; 8:721-727. [PMID: 36695323 PMCID: PMC9972467 DOI: 10.1021/acssensors.2c02251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Molecular switches have become an area of great interest in recent years. They are explored as high-density data storage and organic diodes in molecular electronics as well as chemosensors due to their ability to undergo a transition between well-defined structures under the action of external stimuli. One of the types of such switches is hydrazones. They work by changing the configuration from E to Z under the influence of pH or light. The change in configuration is accompanied by a change in the absorption band and changes in the nuclear magnetic resonance (NMR) spectrum. In this publication, the structure-property relationship of fluorinated hydrazone switches was established. A linear relationship between the Hammett substituent constants and the pH where the switching occurs was found. Introduction of strong electron-donating groups allowed obtaining a hydrazone switch of pKa = 6 suitable for application in 19F MRI as contrast agents.
Collapse
Affiliation(s)
- Dawid Janasik
- Department of Chemical Organic Technology and Petrochemistry, Silesian University of Technology, Krzywoustego 4, 44-100Gliwice, Poland
| | - Patrycja Imielska
- Department of Chemical Organic Technology and Petrochemistry, Silesian University of Technology, Krzywoustego 4, 44-100Gliwice, Poland
| | - Tomasz Krawczyk
- Department of Chemical Organic Technology and Petrochemistry, Silesian University of Technology, Krzywoustego 4, 44-100Gliwice, Poland
| |
Collapse
|
11
|
Zhang S, Qin H, Cheng S, Zhang Y, Gao N, Zhang M. An Electrochemical Nanosensor for Monitoring the Dynamics of Intracellular H 2 O 2 Upon NADH Treatment. Angew Chem Int Ed Engl 2023; 62:e202300083. [PMID: 36807970 DOI: 10.1002/anie.202300083] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 02/13/2023] [Accepted: 02/20/2023] [Indexed: 02/22/2023]
Abstract
Reactive oxygen species (ROS)-based therapeutic strategies play an important role in cancer treatment. However, in situ, real-time and quantitative analysis of intracellular ROS in cancer treatment for drug screening is still a challenge. Herein we report one selective hydrogen peroxide (H2 O2 ) electrochemical nanosensor, which is prepared by electrodeposition of Prussian blue (PB) and polyethylenedioxythiophene (PEDOT) onto carbon fiber nanoelectrode. With the nanosensor, we find that the level of intracellular H2 O2 increases with NADH treatment and that increase is dose-dependent to the concentration of NADH. High-dose of NADH (above 10 mM) can induce cell death and intratumoral injection of NADH is validated for inhibiting tumor growth in mice. This study highlights the potential of electrochemical nanosensor for tracking and understanding the role of H2 O2 in screening new anticancer drug.
Collapse
Affiliation(s)
- Shuai Zhang
- Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Hancheng Qin
- Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Shuwen Cheng
- Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Yue Zhang
- Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Nan Gao
- Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Meining Zhang
- Department of Chemistry, Renmin University of China, Beijing, 100872, China
| |
Collapse
|
12
|
Cheng S, Zhang S, Liu R, Zeng H, Yin Y, Zhang M. Potentiometric nanosensor for real-time measurement of hydrogen sulfide in single cell. Chem Commun (Camb) 2023; 59:1959-1962. [PMID: 36722985 DOI: 10.1039/d2cc06557f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
One potentiometric nanosensor for monitoring intracellular hydrogen sulfide (H2S) with fast potential response, high selectivity and excellent antifouling properties was developed. This study constructs a powerful tool to real-time track the changes of intracellular H2S in situ, promoting the future studies of physiologically relevant processes.
Collapse
Affiliation(s)
- Shuwen Cheng
- Department of Chemistry, Renmin University of China, Beijing, 100872, China.
| | - Shuai Zhang
- Department of Chemistry, Renmin University of China, Beijing, 100872, China.
| | - Rantong Liu
- Department of Chemistry, Renmin University of China, Beijing, 100872, China.
| | - Hui Zeng
- Department of Chemistry, Renmin University of China, Beijing, 100872, China.
| | - Yongyue Yin
- Department of Chemistry, Renmin University of China, Beijing, 100872, China.
| | - Meining Zhang
- Department of Chemistry, Renmin University of China, Beijing, 100872, China.
| |
Collapse
|
13
|
Mukherjee A, Saha PC, Kar S, Guha P, Das RS, Bera T, Guha S. Acidic pH-Triggered Live-Cell Lysosome Specific Tracking, Ratiometric pH Sensing, and Multicolor Imaging by Visible to NIR Switchable Cy-7 Dyes. Chembiochem 2023; 24:e202200641. [PMID: 36459158 DOI: 10.1002/cbic.202200641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 11/28/2022] [Accepted: 12/02/2022] [Indexed: 12/05/2022]
Abstract
We have demonstrated an efficient synthetic route with crystal structures for the construction of acidic pH-triggered visible-to-NIR interchangeable ratiometric fluorescent pH sensors. This bioresponsive probe exhibits pH-sensitive reversible absorption/emission features, low cytotoxicity, a huge 322 nm bathochromic spectral shift with augmented quantum yield from neutral to acidic pH, high sensitivity and selective targeting ability of live-cell lysosomes with ideal pKa , off-to-on narrow NIR absorption/fluorescence signals with high molar absorption coefficient at acidic lysosomal lumen, and in-situ live-cell pH-activated ratiometric imaging of lysosomal pH. Selective staining and ratiometric pH imaging in human carcinoma live-cell lysosomes were monitored by dual-channel confocal laser scanning microscope using a pH-activatable organic fluorescent dye comprising a morpholine moiety for lysosome targeting and an acidic pH openable oxazolidine ring. Moreover, real-time tracking of lysosomes, 3D, and multicolor live-cell imaging have been achieved using the synthesized pH-activatable probe.
Collapse
Affiliation(s)
- Ayan Mukherjee
- Department of Chemistry, Organic Chemistry Section, Jadavpur University, Kolkata, 700032, India
| | - Pranab Chandra Saha
- Department of Chemistry, Organic Chemistry Section, Jadavpur University, Kolkata, 700032, India
| | - Samiran Kar
- Department of Chemistry, Organic Chemistry Section, Jadavpur University, Kolkata, 700032, India
| | - Pampa Guha
- Department of Chemistry, City College, 102/1 Raja Rammohan Sarani, Kolkata, 700009, India
| | - Rabi Sankar Das
- Department of Chemistry, Organic Chemistry Section, Jadavpur University, Kolkata, 700032, India
| | - Tapas Bera
- Department of Chemistry, Organic Chemistry Section, Jadavpur University, Kolkata, 700032, India
| | - Samit Guha
- Department of Chemistry, Organic Chemistry Section, Jadavpur University, Kolkata, 700032, India
| |
Collapse
|
14
|
Al-Jeda M, Mena-Morcillo E, Chen A. Micro-Sized pH Sensors Based on Scanning Electrochemical Probe Microscopy. MICROMACHINES 2022; 13:2143. [PMID: 36557442 PMCID: PMC9785626 DOI: 10.3390/mi13122143] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 11/29/2022] [Accepted: 12/01/2022] [Indexed: 06/17/2023]
Abstract
Monitoring pH changes at the micro/nano scale is essential to gain a fundamental understanding of surface processes. Detection of local pH changes at the electrode/electrolyte interface can be achieved through the use of micro-/nano-sized pH sensors. When combined with scanning electrochemical microscopy (SECM), these sensors can provide measurements with high spatial resolution. This article reviews the state-of-the-art design and fabrication of micro-/nano-sized pH sensors, as well as their applications based on SECM. Considerations for selecting sensing probes for use in biological studies, corrosion science, in energy applications, and for environmental research are examined. Different types of pH sensitive probes are summarized and compared. Finally, future trends and emerging applications of micro-/nano-sized pH sensors are discussed.
Collapse
Affiliation(s)
| | | | - Aicheng Chen
- Correspondence: ; Tel.: +1-519-824-4120 (ext. 54764)
| |
Collapse
|
15
|
Micro- and nano-devices for electrochemical sensing. Mikrochim Acta 2022; 189:459. [DOI: 10.1007/s00604-022-05548-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 11/02/2022] [Indexed: 11/24/2022]
Abstract
AbstractElectrode miniaturization has profoundly revolutionized the field of electrochemical sensing, opening up unprecedented opportunities for probing biological events with a high spatial and temporal resolution, integrating electrochemical systems with microfluidics, and designing arrays for multiplexed sensing. Several technological issues posed by the desire for downsizing have been addressed so far, leading to micrometric and nanometric sensing systems with different degrees of maturity. However, there is still an endless margin for researchers to improve current strategies and cope with demanding sensing fields, such as lab-on-a-chip devices and multi-array sensors, brain chemistry, and cell monitoring. In this review, we present current trends in the design of micro-/nano-electrochemical sensors and cutting-edge applications reported in the last 10 years. Micro- and nanosensors are divided into four categories depending on the transduction mechanism, e.g., amperometric, impedimetric, potentiometric, and transistor-based, to best guide the reader through the different detection strategies and highlight major advancements as well as still unaddressed demands in electrochemical sensing.
Graphical Abstract
Collapse
|
16
|
Drago NP, Choi EJ, Shin J, Kim DH, Penner RM. A Nanojunction pH Sensor within a Nanowire. Anal Chem 2022; 94:12167-12175. [PMID: 36001648 DOI: 10.1021/acs.analchem.2c02606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
pH sensors that are nanoscopic in all three dimensions are fabricated within a single gold nanowire. Fabrication involves the formation of a nanogap within the nanowire via electromigration, followed by electropolymerization of pH-responsive poly(aniline) (PANI) that fills the nanogap forming the nanojunction. All fabrication steps are performed using wet chemical methods that do not require a clean room. The measured electrical impedance of the PANI nanojunction is correlated with pH from 2.0 to 9.0 with a response time of 30 s. Larger, micrometer-scale PANI junctions exhibit a slower response. The measured pH is weakly influenced by the salt concentration of the contacting aqueous solution. An impedance measurement at two frequencies (300 kHz and 1.0 Hz) enables estimation of the salt concentration and correction of the measured pH value, preserving the accuracy of the pH measurement across the entire calibration curve for salt concentrations up to 1.0 M. The result is a nanoscopic pH sensor with pH sensing performance approaching that of a conventional, macroscopic pH glass-membrane electrode.
Collapse
Affiliation(s)
- Nicholas P Drago
- Department of Chemistry, University of California, Irvine, California 92697-2025, United States
| | - Eric J Choi
- Department of Chemistry, University of California, Irvine, California 92697-2025, United States
| | - Jihoon Shin
- School of Chemical Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do 16419, South Korea
| | - Dong-Hwan Kim
- School of Chemical Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do 16419, South Korea
| | - Reginald M Penner
- Department of Chemistry, University of California, Irvine, California 92697-2025, United States
| |
Collapse
|