1
|
Ma Y, Sun X, Cai Z, Tu M, Wang Y, Ouyang Q, Yan X, Jing G, Yang G. Transformation gap from research findings to large-scale commercialized products in microfluidic field. Mater Today Bio 2024; 29:101373. [PMID: 39687794 PMCID: PMC11647665 DOI: 10.1016/j.mtbio.2024.101373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2024] [Revised: 11/13/2024] [Accepted: 11/27/2024] [Indexed: 12/18/2024] Open
Abstract
The field of microfluidics has experienced rapid growth in the last several decades, yet it isn't considered to be a large industry comparable to semiconductor and consumer electronics. In this review, we analyzed the entire process of the transformation from research findings to commercialized products in microfluidics, as well as the significant gap during the whole developing process between microchip fabrication in R&D and large-scale production in the industry. We elaborated in detail on various materials in the microfluidics industry, including silicon, glass, PDMS, and thermoplastics, discussing their characteristics, production processes, and existing products. Despite challenges hindering the large-scale commercialization of microfluidic chips, ongoing advancements and applications are expected to integrate microfluidic technology into everyday life, transforming it into a commercially viable field with substantial potential and promising prospects.
Collapse
Affiliation(s)
- Yuqi Ma
- State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing, 100871, China
| | - Xiaoyi Sun
- State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing, 100871, China
| | - Ziwei Cai
- State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing, 100871, China
| | - Mengjing Tu
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, 352001, China
| | - Yugang Wang
- State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing, 100871, China
| | - Qi Ouyang
- Center for Quantitative Biology, Peking University, Beijing, 100871, China
| | - Xueqing Yan
- State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing, 100871, China
| | - Gaoshan Jing
- Institute of Microelectronics, Chinese Academy of Sciences (CAS), Beijing, 100029, China
| | - Gen Yang
- State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing, 100871, China
| |
Collapse
|
2
|
Su K, Li J, Liu H, Zou Y. Emerging Trends in Integrated Digital Microfluidic Platforms for Next-Generation Immunoassays. MICROMACHINES 2024; 15:1358. [PMID: 39597170 PMCID: PMC11596068 DOI: 10.3390/mi15111358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2024] [Revised: 10/12/2024] [Accepted: 11/04/2024] [Indexed: 11/29/2024]
Abstract
Technologies based on digital microfluidics (DMF) have made significant advancements in the automated manipulation of microscale liquids and complex multistep processes. Due to their numerous benefits, such as automation, speed, cost-effectiveness, and minimal sample volume requirements, these systems are particularly well suited for immunoassays. In this review, an overview is provided of diverse DMF manipulation platforms and their applications in immunological analysis. Initially, droplet-driven DMF platforms based on electrowetting on dielectric (EWOD), magnetic manipulation, surface acoustic wave (SAW), and other related technologies are briefly introduced. The preparation of DMF is then described, including material selection, fabrication techniques and droplet generation. Subsequently, a comprehensive account of advancements in the integration of DMF with various immunoassay techniques is offered, encompassing colorimetric, direct chemiluminescence, enzymatic chemiluminescence, electrosensory, and other immunoassays. Ultimately, the potential challenges and future perspectives in this burgeoning field are delved into.
Collapse
Affiliation(s)
- Kaixin Su
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China; (K.S.); (J.L.); (H.L.)
| | - Jiaqi Li
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China; (K.S.); (J.L.); (H.L.)
| | - Hailan Liu
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China; (K.S.); (J.L.); (H.L.)
| | - Yuan Zou
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing 400016, China; (K.S.); (J.L.); (H.L.)
- Western (Chongqing) Collaborative Innovation Center for Intelligent Diagnostics and Digital Medicine, Chongqing 401329, China
| |
Collapse
|
3
|
Weise C, Schirmer M, Polack M, Korell A, Westphal H, Schwieger J, Warias R, Zimmermann S, Belder D. Modular Chip-Based nanoSFC-MS for Ultrafast Separations. Anal Chem 2024; 96. [PMID: 39152902 PMCID: PMC11359387 DOI: 10.1021/acs.analchem.4c01958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 07/17/2024] [Accepted: 08/07/2024] [Indexed: 08/19/2024]
Abstract
This study presents the development of a miniaturized device for supercritical fluid chromatography coupled with mass spectrometry. The chip-based, modular nanoSFC approach utilizes a particle-packed nanobore column embedded between two monolithically structured glass chips. A microtee in the pre-column section ensures picoliter sample loads onto the column, while a microcross chip structure fluidically controls the column backpressure. The restrictive emitter and the minimal post-column volume of 16 nL prevent mobile phase decompression and analyte dilution, maintaining chromatographic integrity during transfer to the atmospheric pressure MS interface. This facilitates high-speed chiral separations in less than 80 s with high reproducibility.
Collapse
Affiliation(s)
- Chris Weise
- University
Leipzig, Linnestrasse 3, Leipzig 04103, Germany
| | | | | | | | | | | | - Rico Warias
- University
Leipzig, Linnestrasse 3, Leipzig 04103, Germany
| | - Stefan Zimmermann
- Leibniz
University Hannover, Appelstrasse 9a, Hannover 30167, Germany
| | - Detlev Belder
- University
Leipzig, Linnestrasse 3, Leipzig 04103, Germany
| |
Collapse
|
4
|
Weise C, Fischer J, Belder D. Mass spectrometry coupling of chip-based supercritical fluid chromatography enabled by make-up flow-assisted backpressure regulation. Anal Bioanal Chem 2024; 416:4447-4456. [PMID: 38907770 PMCID: PMC11294422 DOI: 10.1007/s00216-024-05381-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 05/17/2024] [Accepted: 05/31/2024] [Indexed: 06/24/2024]
Abstract
This work introduces a novel microfluidic backpressure pressure control developed for chip-based supercritical fluid chromatography (chipSFC). The presented on-chip pressure control mechanism involves the post-column addition of a viscous make-up stream, which enables pressure regulation within the range of 73 to 130 bar range. In contrast to approaches using mechanical backpressure regulators, this chip-based make-up-assisted pressure regulation offers a wear-free alternative that functions entirely through fluidic means and contributes minimally to extra column volume. It prevents phase separation of the supercritical mobile phase and, therefore, expands the analytical scope of chipSFC to detection systems with an ambient pressure interface. This was demonstrated by a proof-of-principle experiment, where a model mixture was separated within 30 s and detected using atmospheric pressure ionisation mass spectrometry.
Collapse
Affiliation(s)
- Chris Weise
- Institute of Analytical Chemistry, University of Leipzig, Linnéstrasse 3, 04103, Leipzig, Germany
| | - Johannes Fischer
- Institute of Analytical Chemistry, University of Leipzig, Linnéstrasse 3, 04103, Leipzig, Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, University of Leipzig, Linnéstrasse 3, 04103, Leipzig, Germany.
| |
Collapse
|
5
|
Broeckhoven K. Advances in the limits of separation power in supercritical fluid chromatography. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2021.116489] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
6
|
An X, Pan X, Li R, Jiang D, Dong F, Zhu W, Xu J, Liu X, Wu X, Zheng Y. Enantioselective monitoring chiral fungicide mefentrifluconazole in tomato, cucumber, pepper and its pickled products by supercritical fluid chromatography tandem mass spectrometry. Food Chem 2021; 376:131883. [PMID: 34971887 DOI: 10.1016/j.foodchem.2021.131883] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2021] [Revised: 12/12/2021] [Accepted: 12/14/2021] [Indexed: 12/19/2022]
Abstract
A fast, effective, and environmental-friendly method was developed for enantioseparation and analysis of mefentrifluconazole in vegetables based on supercritical fluid chromatography tandem mass spectrometry. The enantioselective behaviors of mefentrifluconazole enantiomers in tomato, cucumber, and pepper in the greenhouse, and pickled cucumber and pepper during processing were investigated. Mefentrifluconazole enantiomers could obtain baseline separation within 2 min. The average recoveries of all matrices ranged from 78.4% to 119.0%, with relative standard deviations less than 16.8% for two enantiomers. S-(+)-mefentrifluconazole was preferentially degraded in pepper, while there was no enantioselectivity in tomato and cucumber under field conditions. During processing, S-(+)-mefentrifluconazole was reduced preferentially than R-(-)-mefentrifluconazole in pickled cucumber and cucumber brine. Inversely, R-(-)-mefentrifluconazole degraded faster than S-(+)-mefentrifluconazole in pepper brine. But, no obvious enantioselectivity was observed in pickled pepper. The result of this study could contribute to a more accurate dietary risk assessment of mefentrifluconazole in vegetables and processed products.
Collapse
Affiliation(s)
- Xiaokang An
- State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing 100193, China; Department of Applied Chemistry, China Agricultural University, Beijing 100193, China
| | - Xinglu Pan
- State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing 100193, China
| | - Runan Li
- State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing 100193, China
| | - Duoduo Jiang
- State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing 100193, China
| | - Fengshou Dong
- State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing 100193, China.
| | - Wentao Zhu
- Department of Applied Chemistry, China Agricultural University, Beijing 100193, China
| | - Jun Xu
- State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing 100193, China
| | - Xingang Liu
- State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing 100193, China
| | - Xiaohu Wu
- State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing 100193, China
| | - Yongquan Zheng
- State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Beijing 100193, China
| |
Collapse
|
7
|
Li D, Luo K, Zhang L, Gao J, Liang J, Li J, Pan H. Research and Application of Highly Selective Molecular Imprinting Technology in Chiral Separation Analysis. Crit Rev Anal Chem 2021; 53:1066-1079. [PMID: 34802340 DOI: 10.1080/10408347.2021.2002680] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
Since residual chiral pollutants in the environment and toxic or ineffective chiral components in drugs can threat human health, there is an urgent need for methods to separation and analyze chiral molecules. Molecular imprinting technology (MIT) is a biomimetic technique for specific recognition of analytes with high potential for application in the field of chiral separation and analysis. However, since MIT has some disadvantages when used for chiral recognition, such as poor rigidity of imprinted materials, a single type of recognition site, and poor stereoselectivity, reducing the interference of conformationally and structurally similar substances to increase the efficiency of chiral recognition is difficult. Therefore, improving the rigidity of imprinted materials, increasing the types of imprinted cavity recognition sites, and constructing an imprinted microenvironment for highly selective chiral recognition are necessary for the accurate identification of chiral substances. In this article, the principle of chiral imprinting recognition is introduced, and various strategies that improve the selectivity of chiral imprinting, using derivative functional monomers, supramolecular compounds, chiral assembly materials, and biomolecules, are reviewed in the past 10 years.
Collapse
Affiliation(s)
- Dan Li
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Kui Luo
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Lianming Zhang
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Jingxia Gao
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Jinlu Liang
- School of Petroleum and Chemical Engineering, BeiBu Gulf University, Qinzhou, China
| | - Jianping Li
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| | - Hongcheng Pan
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, China
| |
Collapse
|
8
|
Two-photon fluorescence lifetime for label-free microfluidic droplet sorting. Anal Bioanal Chem 2021; 414:721-730. [PMID: 34792636 PMCID: PMC8748334 DOI: 10.1007/s00216-021-03745-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 10/14/2021] [Accepted: 10/19/2021] [Indexed: 12/19/2022]
Abstract
Microfluidic droplet sorting systems facilitate automated selective micromanipulation of compartmentalized micro- and nano-entities in a fluidic stream. Current state-of-the-art droplet sorting systems mainly rely on fluorescence detection in the visible range with the drawback that pre-labeling steps are required. This limits the application range significantly, and there is a high demand for alternative, label-free methods. Therefore, we introduce time-resolved two-photon excitation (TPE) fluorescence detection with excitation at 532 nm as a detection technique in droplet microfluidics. This enables label-free in-droplet detection of small aromatic compounds that only absorb in a deep-UV spectral region. Applying time-correlated single-photon counting, compounds with similar emission spectra can be distinguished due to their fluorescence lifetimes. This information is then used to trigger downstream dielectrophoretic droplet sorting. In this proof-of-concept study, we developed a polydimethylsiloxane-fused silica (FS) hybrid chip that simultaneously provides a very high optical transparency in the deep-UV range and suitable surface properties for droplet microfluidics. The herein developed system incorporating a 532-nm picosecond laser, time-correlated single-photon counting (TCSPC), and a chip-integrated dielectrophoretic pulsed actuator was exemplarily applied to sort droplets containing serotonin or propranolol. Furthermore, yeast cells were screened using the presented platform to show its applicability to study cells based on their protein autofluorescence via TPE fluorescence lifetime at 532 nm.
Collapse
|
9
|
Yamamoto K, Machida K, Kotani A, Hakamata H. Emerging Separation Techniques in Supercritical Fluid Chromatography. Chem Pharm Bull (Tokyo) 2021; 69:970-975. [PMID: 34602578 DOI: 10.1248/cpb.c21-00306] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Supercritical fluid chromatography (SFC) has unique separative characteristics distinguished from those of HPLC and gas chromatography. At present, SFC is widely used and there are many applications in various biological, medical, and pharmaceutical fields. In this review, we focus on recently developed novel techniques related to SFC separation including: new column stationary phases, microfluidics, two-dimensional separation, and gas-liquid separation. In addition, we discuss the application of SFC using a water-containing modifier to biological molecules such as amino acids, peptides, and small proteins that had been challenging analytes.
Collapse
Affiliation(s)
- Kazuhiro Yamamoto
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences
| | - Koichi Machida
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences
| | - Akira Kotani
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences
| | - Hideki Hakamata
- Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences
| |
Collapse
|
10
|
Hondo T, Ota C, Miyake Y, Furutani H, Toyoda M. Analysis of Nonvolatile Molecules in Supercritical Carbon Dioxide Using Proton-Transfer-Reaction Ionization Time-of-Flight Mass Spectrometry. Anal Chem 2021; 93:6589-6593. [PMID: 33891393 DOI: 10.1021/acs.analchem.1c00898] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Proton-transfer-reaction (PTR) mass spectrometry (MS) is capable of detecting trace-level volatile organic compounds (VOCs) in gaseous samples in real time. Therefore, PTR-MS has become a popular method in many different study areas. Most of the currently reported PTR-MS applications are designed to determine volatile compounds. However, the method might be applicable for nonvolatile organic compound detection. Supercritical fluid chromatography (SFC) has been studied in the last 5 decades. This approach has high separation efficiency and predictable retention behavior, making separation optimization easy. Atmospheric ionization techniques, such as atmospheric chemical ionization (APCI) and electrospray ionization (ESI), are the most studied SFC-MS interfaces. These processes require the addition of makeup solvents to prevent precipitation or crystallization of the solute while depressurizing the mobile phase. In contrast, the PTR process is carried out in a vacuum; supercritical carbon dioxide may release solute into the PTR flow tube without a phase transition as long as it is maintained above a critical temperature. Therefore, this might constitute yet another use for the SFC-MS interface. Caffeine and a few other nonpolar compounds in supercritical carbon dioxide were successfully detected with time-of-flight MS without adding solvent by using preliminarily assembled supercritical flow injection and supercritical fluid extraction (SFE)-PTR interfaces.
Collapse
Affiliation(s)
- Toshinobu Hondo
- Project Research Center for Fundamental Sciences, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043, Japan.,MS-Cheminformatics LLC, 2-13-21 Sasaonishi, Toin, Mie 511-0231, Japan
| | - Chihiro Ota
- Department of Chemistry and Materials Engineering, Faculty of Chemistry, Materials and Bioengineering, Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680, Japan
| | - Yumi Miyake
- Project Research Center for Fundamental Sciences, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043, Japan
| | - Hiroshi Furutani
- Project Research Center for Fundamental Sciences, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043, Japan.,Center for Scientific Instrument Renovation and Manufacturing Support, Osaka University, 1-2 Machikaneyama, Toyonaka, Osaka 560-0043, Japan
| | - Michisato Toyoda
- Project Research Center for Fundamental Sciences, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043, Japan
| |
Collapse
|
11
|
Abstract
Miniaturization is an important trend in modern analytical instrument development, including miniaturized gas chromatography and liquid chromatography, as well as micro bore columns and capillary-to-microfluidics-based platforms. Apart from the miniaturization of the separation column, which is the core part of a chromatographic system, other parts of the system, including the sampler, pumping system, gradient generation, and detection systems, have been miniaturized. Miniaturized liquid chromatography significantly reduces solvent and sample consumption while providing comparable or even better separation efficiency. When liquid chromatography is coupled with mass spectroscopy, a low flow rate can increase the ionization efficiency, leading to enhanced sensitivity of the mass spectrometer. In contrast, normal-scale liquid chromatography suffers from its relatively high volumetric flow rate, which challenges the scanning frequency of the mass spectrometer. On the other hand because of the small sample size, other detection strategies such as spectrometric methods cannot provide sufficient sensitivity and limits of detection. In this sense, mass spectrometry has become the detection method of choice for micro-scale liquid-phase chromatography. Miniaturized liquid chromatography can diminish sample dilution efficiently when extremely small amounts of samples are used. The main driving force for this miniaturization trend, especially in liquid-phase separations, is the desperate need for microscale analyses of biological and clinical samples, given these samples are precious and the sample size is usually very small. At present, microscale liquid-phase chromatography is the only method of choice for such small, precious, and highly informative samples. The miniaturization of liquid chromatography systems, especially chromatographic columns, would be advantageous to the modularization and integration of liquid chromatography instrumental systems. Chip liquid chromatography is an integration of chromatography columns, liquid control systems, and detection methods on a single microfluidic chip. Chip liquid chromatography is an excellent format for the miniaturization of liquid chromatography systems, and it has already attracted significant attention from academia and industry. However, this attempt is challenging, and great effort is required on fundamental techniques, such as the substrate material of the microfluidic chip, structure of the micro-chromatography column, fluid control method, and detection methods, in order to make the chips suitable for liquid chromatography. Currently, the major problem in chip liquid chromatography is that the properties of the chip substrate materials cannot meet the requirements for further miniaturization and integration of chip liquid chromatography. The strength of the existing chip substrate materials is generally below 60 MPa, and the material properties limit further advances in the miniaturization and integration of chromatographic chips. Therefore, new chip substrate materials and the standard of chip channel design such as channel size and channel structure should be the key for further development of chip liquid chromatography. Mainstream instrumentation companies as well as new start-up innovation companies are now undertaking efforts toward the development of microchip liquid chromatographic products. Agilent, the first instrumentation company that introduced commercial microchip liquid chromatographic columns to the market, has led this field. Apart from microchip-based columns, Agilent introduced trap columns for different kinds of biological molecules as well as gradient generation systems for microchip-based liquid phase chromatography. Recently, another start-up company introduced microchip columns based on the in situ microfabrication of the column bed rather than packing the column with a particulate material. Such developments in microfabrication may further propel the advancement of micro-scale liquid-phase chromatography to an unprecedented level, which is beyond the conventional components and materials employed in normal-scale liquid chromatography. This review introduces the recent research progress in microchip liquid chromatography technologies, and briefly discusses the current state of commercialization of microchips for liquid chromatography by major instrumentation companies.
Collapse
Affiliation(s)
- Hanrong WEN
- 厦门大学化学化工学院, 福建 厦门 361005
- College of Chemistry & Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Jue ZHU
- 厦门大学化学化工学院, 福建 厦门 361005
- College of Chemistry & Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Bo ZHANG
- 厦门大学化学化工学院, 福建 厦门 361005
- College of Chemistry & Chemical Engineering, Xiamen University, Xiamen 361005, China
| |
Collapse
|
12
|
Wahab MF, Roy D, Armstrong DW. The theory and practice of ultrafast liquid chromatography: A tutorial. Anal Chim Acta 2020; 1151:238170. [PMID: 33608081 DOI: 10.1016/j.aca.2020.12.045] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 12/20/2020] [Accepted: 12/22/2020] [Indexed: 11/30/2022]
Abstract
Modern high-throughput experimentation and challenging analytical problems of academic/industrial research have put the responsibility on separation scientists to develop new fast separation approaches. With the availability of high-pressure pumps, small particles with hydrolytically stable surface chemistries, reduced extra-column band broadening, and low volume detectors with fast signal processing, it is now feasible to do sub-minute to sub-second chromatography. Herein, the fundamental theoretical principles of ultrafast chromatography, along with practical solutions, are reviewed. Approaches for rapid separations in packed beds, narrow open tubular columns, and monoliths are demonstrated, along with the challenges that were faced. The instrumentation requirements (pumps, injection systems, detectors, column packing process) for using short columns ranging from 0.5 to 5 cm are examined, followed by real applications. One of the main problems in ultrafast chromatography is partial or complete peak overlap. As per Gidding's statistical overlap theory, peak overlap cannot be avoided for a completely random sample for a column with a given peak capacity. Signal processing techniques based on Fourier transform deconvolution of band broadening, power laws, derivatives, and iterative curve fitting are explained to help improve the chromatographic resolution. An example of ten peaks separated in under a second is shown and discussed. Other ultrafast separations in supercritical fluid chromatography or capillary electrophoresis are briefly mentioned to provide a complete understanding of this emerging field.
Collapse
Affiliation(s)
- M Farooq Wahab
- Department of Chemistry & Biochemistry, University of Texas at Arlington, TX, USA.
| | - Daipayan Roy
- Department of Chemistry & Biochemistry, University of Texas at Arlington, TX, USA
| | - Daniel W Armstrong
- Department of Chemistry & Biochemistry, University of Texas at Arlington, TX, USA.
| |
Collapse
|
13
|
Liu L, Li G, Xiang N, Huang X, Shiba K. Microfluidic Production of Autofluorescent BSA Hydrogel Microspheres and Their Sequential Trapping for Fluorescence-Based On-Chip Permanganate Sensing. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5886. [PMID: 33080899 PMCID: PMC7594029 DOI: 10.3390/s20205886] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 10/15/2020] [Accepted: 10/15/2020] [Indexed: 12/14/2022]
Abstract
Microfabrication technologies have extensively advanced over the past decades, realizing a variety of well-designed compact devices for material synthesis, separation, analysis, monitoring, sensing, and so on. The performance of such devices has been undoubtedly improved, while it is still challenging to build up a platform by rationally combining multiple processes toward practical demands which become more diverse and complicated. Here, we present a simple and effective microfluidic system to produce and immobilize a well-defined functional material for on-chip permanganate (MnO4-) sensing. A droplet-based microfluidic approach that can continuously produce monodispersed droplets in a water-in-oil system is employed to prepare highly uniform microspheres (average size: 102 μm, coefficient of variation: 3.7%) composed of bovine serum albumin (BSA) hydrogel with autofluorescence properties in the presence of glutaraldehyde (GA). Each BSA hydrogel microsphere is subsequently immobilized in a microchannel with a hydrodynamic trapping structure to serve as an independent fluorescence unit. Various anions such as Cl-, NO3-, PO43-, Br-, BrO3-, ClO4-, SCN-, HCO3-, and MnO4- are individually flowed into the microchannel, resulting in significant fluorescence quenching only in the case of MnO4-. Linear correlation is confirmed at an MnO4- concentration from 20 to 80 μM, and a limit of detection is estimated to be 1.7 μM. Furthermore, we demonstrate the simultaneous immobilization of two kinds of different microspheres in parallel microchannels, pure BSA hydrogel microspheres and BSA hydrogel microspheres containing rhodamine B molecules, making it possible to acquire two fluorescence signals (green and yellow). The present microfluidics-based combined approach will be useful to record a fingerprint of complicated samples for sensing/identification purposes by flexibly designing the size and composition of the BSA hydrogel microspheres, immobilizing them in a desired manner and obtaining a specific pattern.
Collapse
Affiliation(s)
- Linbo Liu
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA; (L.L.); (X.H.)
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing 211189, China;
| | - Guangming Li
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA; (L.L.); (X.H.)
- State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Changchun 130022, China
- State Key Laboratory of Rare Earth Resource Utilization, University of Science and Technology of China, Hefei 230026, China
| | - Nan Xiang
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing 211189, China;
| | - Xing Huang
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA; (L.L.); (X.H.)
- Institute of Process Equipment, College of Energy Engineering, Zhejiang University, Hangzhou 310027, China
| | - Kota Shiba
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA; (L.L.); (X.H.)
- Center for Functional Sensor & Actuator (CFSN), National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan
| |
Collapse
|
14
|
Li Z, Mao Z, Zhou W, Chen Z. γ-Cyclodextrin metal-organic framework supported by polydopamine as stationary phases for electrochromatographic enantioseparation. Talanta 2020; 218:121160. [DOI: 10.1016/j.talanta.2020.121160] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 05/07/2020] [Accepted: 05/10/2020] [Indexed: 01/25/2023]
|
15
|
Li K, Hu W, Zhou Y, Dou X, Wang X, Zhang B, Guo G. Single-particle-frit-based packed columns for microchip chromatographic analysis of neurotransmitters. Talanta 2020; 215:120896. [PMID: 32312441 DOI: 10.1016/j.talanta.2020.120896] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 02/28/2020] [Accepted: 03/03/2020] [Indexed: 11/18/2022]
Abstract
The fabrication of effective microchip liquid chromatography (LC) systems tends to be limited by the availability of suitable chromatographic columns. Herein, we developed a glass microchip LC system in which porous single-particle silica was adopted as frits and a freeze-thaw valve was utilized to achieve sample injection without interfering with sampling. The fabrication of single-particle-frit-based packed columns did not require an additional packing channel, thus avoiding dead volumes within the channel interface that can influence chromatographic separation. Further, the length of the packed column could be adjusted using the location of single-particle frits within the column channel. The fabricated frits exhibited high mechanical strength, good permeability, and tolerance for high pressures during chromatographic separation. In particular, the developed microchip LC system was able to withstand high separation pressures of more than 5000 psi. The microchip LC system was applied to the separation of neurotransmitters. Three different monoamine neurotransmitters were completely separated within 5 min with theoretical plate numbers on the order of 100,000 plates m-1. The microchip LC system has a potential for application in a variety of fields including environmental analysis, food safety, drug analysis, and biomedicine.
Collapse
Affiliation(s)
- Ke Li
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China
| | - Wangyan Hu
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China
| | - Yingyan Zhou
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China
| | - Xiangnan Dou
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China
| | - Xiayan Wang
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China.
| | - Bo Zhang
- College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, PR China
| | - Guangsheng Guo
- Center of Excellence for Environmental Safety and Biological Effects, Beijing Key Laboratory for Green Catalysis and Separation, Department of Chemistry and Chemistry Engineering, Beijing University of Technology, Beijing, 100124, PR China.
| |
Collapse
|
16
|
Potential and current limitations of superficially porous silica as a carrier for polysaccharide-based chiral selectors in separation of enantiomers in high-performance liquid chromatography. J Chromatogr A 2020; 1625:461297. [DOI: 10.1016/j.chroma.2020.461297] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 05/17/2020] [Accepted: 05/30/2020] [Indexed: 01/03/2023]
|
17
|
Lian H, Huang S, Wei X, Guo J, Sun X, Liu B. Gold nanodendrite-based differential potential ratiometric sensing strategy for enantioselective recognition of DOPA. Talanta 2020; 210:120654. [DOI: 10.1016/j.talanta.2019.120654] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 12/13/2019] [Accepted: 12/19/2019] [Indexed: 02/04/2023]
|
18
|
Nielsen JB, Hanson RL, Almughamsi HM, Pang C, Fish TR, Woolley AT. Microfluidics: Innovations in Materials and Their Fabrication and Functionalization. Anal Chem 2020; 92:150-168. [PMID: 31721565 PMCID: PMC7034066 DOI: 10.1021/acs.analchem.9b04986] [Citation(s) in RCA: 135] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Jacob B. Nielsen
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700, USA
| | - Robert L. Hanson
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700, USA
| | - Haifa M. Almughamsi
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700, USA
| | - Chao Pang
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700, USA
| | - Taylor R. Fish
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700, USA
| | - Adam T. Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700, USA
| |
Collapse
|
19
|
Carrão DB, Perovani IS, de Albuquerque NCP, de Oliveira ARM. Enantioseparation of pesticides: A critical review. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2019.115719] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
20
|
Kaplitz AS, Kresge GA, Selover B, Horvat L, Franklin EG, Godinho JM, Grinias KM, Foster SW, Davis JJ, Grinias JP. High-Throughput and Ultrafast Liquid Chromatography. Anal Chem 2019; 92:67-84. [DOI: 10.1021/acs.analchem.9b04713] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Alexander S. Kaplitz
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Glenn A. Kresge
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Benjamin Selover
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Leah Horvat
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | | | - Justin M. Godinho
- Advanced Materials Technology, Inc., Wilmington, Delaware 19810, United States
| | - Kaitlin M. Grinias
- Analytical Platforms & Platform Modernization, GlaxoSmithKline, Upper Providence, Collegeville, Pennsylvania 19426, United States
| | - Samuel W. Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Joshua J. Davis
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - James P. Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| |
Collapse
|
21
|
Abstract
Nano liquid chromatography (nanoLC), with columns having an inner diameter (ID) of ≤100 μm, can provide enhanced sensitivity and enable analysis of limited samples.
Collapse
Affiliation(s)
- Steven Ray Wilson
- Department of Chemistry
- University of Oslo
- Oslo
- Norway
- Hybrid Technology Hub-Centre of Excellence
| | | | | |
Collapse
|