1
|
Ernenwein D, Geisler I, Pavlishchuk A, Chmielewski J. Metal-Assembled Collagen Peptide Microflorettes as Magnetic Resonance Imaging Agents. Molecules 2023; 28:molecules28072953. [PMID: 37049716 PMCID: PMC10095756 DOI: 10.3390/molecules28072953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 03/15/2023] [Accepted: 03/22/2023] [Indexed: 03/29/2023] Open
Abstract
Magnetic resonance imaging (MRI) is a medical imaging technique that provides detailed information on tissues and organs. However, the low sensitivity of the technique requires the use of contrast agents, usually ones that are based on the chelates of gadolinium ions. In an effort to improve MRI signal intensity, we developed two strategies whereby the ligand DOTA and Gd(III) ions are contained within Zn(II)-promoted collagen peptide (NCoH) supramolecular assemblies. The DOTA moiety was included in the assembly either via a collagen peptide sidechain (NHdota) or through metal–ligand interactions with a His-tagged DOTA conjugate (DOTA-His6). SEM verified that the morphology of the NCoH assembly was maintained in the presence of the DOTA-containing peptides (microflorettes), and EDX and ICP-MS confirmed that Gd(III) ions were incorporated within the microflorettes. The Gd(III)-loaded DOTA florettes demonstrated higher intensities for the T1-weighted MRI signal and higher longitudinal relaxivity (r1) values, as compared to the clinically used contrast agent Magnevist. Additionally, no appreciable cellular toxicity was observed with the collagen microflorettes loaded with Gd(III). Overall, two peptide-based materials were generated that have potential as MRI contrast agents.
Collapse
|
2
|
Madej-Kiełbik L, Gzyra-Jagieła K, Jóźwik-Pruska J, Dziuba R, Bednarowicz A. Biopolymer Composites with Sensors for Environmental and Medical Applications. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7493. [PMID: 36363084 PMCID: PMC9659006 DOI: 10.3390/ma15217493] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 10/13/2022] [Accepted: 10/21/2022] [Indexed: 06/16/2023]
Abstract
One of the biggest economic and environmental sustainability problems is the over-reliance on petroleum chemicals in polymer production. This paper presents an overview of the current state of knowledge on biopolymers combined with biosensors in terms of properties, compounding methods and applications, with a focus on medical and environmental aspects. Therefore, this article is devoted to environmentally friendly polymer materials. The paper presents an overview of the current state of knowledge on biopolymers combined with biosensors in terms of properties, compounding methods and applications, with a special focus on medical and environmental aspects. The paper presents the current state of knowledge, as well as prospects. The article shows that biopolymers made from renewable raw materials are of great interest in various fields of science and industry. These materials not only replace existing polymers in many applications, but also provide new combinations of properties for new applications. Composite materials based on biopolymers are considered superior to traditional non-biodegradable materials due to their ability to degrade when exposed to environmental factors. The paper highlights the combination of polymers with nanomaterials which allows the preparation of chemical sensors, thus enabling their use in environmental or medical applications due to their biocompatibility and sensitivity. This review focuses on analyzing the state of research in the field of biopolymer-sensor composites.
Collapse
Affiliation(s)
- Longina Madej-Kiełbik
- Lukasiewicz Research Network—Lodz Institute of Technology, 19/27 M. Sklodowskiej-Curie Str., 90-570 Lodz, Poland
| | - Karolina Gzyra-Jagieła
- Lukasiewicz Research Network—Lodz Institute of Technology, 19/27 M. Sklodowskiej-Curie Str., 90-570 Lodz, Poland
- Faculty of Material Technologies and Textile Design, Lodz University of Technology, 116 Żeromskiego Street, 90-924 Lodz, Poland
| | - Jagoda Jóźwik-Pruska
- Lukasiewicz Research Network—Lodz Institute of Technology, 19/27 M. Sklodowskiej-Curie Str., 90-570 Lodz, Poland
| | - Radosław Dziuba
- Department of World Economy and European Integration, University of Lodz, 41/43 Rewolucji 1905 Str., 90-214 Lodz, Poland
| | - Anna Bednarowicz
- Lukasiewicz Research Network—Lodz Institute of Technology, 19/27 M. Sklodowskiej-Curie Str., 90-570 Lodz, Poland
- Faculty of Material Technologies and Textile Design, Lodz University of Technology, 116 Żeromskiego Street, 90-924 Lodz, Poland
| |
Collapse
|
3
|
Application of Dendrimers in Anticancer Diagnostics and Therapy. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27103237. [PMID: 35630713 PMCID: PMC9144149 DOI: 10.3390/molecules27103237] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Revised: 05/11/2022] [Accepted: 05/16/2022] [Indexed: 11/16/2022]
Abstract
The application of dendrimeric constructs in medical diagnostics and therapeutics is increasing. Dendrimers have attracted attention due to their compact, spherical three-dimensional structures with surfaces that can be modified by the attachment of various drugs, hydrophilic or hydrophobic groups, or reporter molecules. In the literature, many modified dendrimer systems with various applications have been reported, including drug and gene delivery systems, biosensors, bioimaging contrast agents, tissue engineering, and therapeutic agents. Dendrimers are used for the delivery of macromolecules, miRNAs, siRNAs, and many other various biomedical applications, and they are ideal carriers for bioactive molecules. In addition, the conjugation of dendrimers with antibodies, proteins, and peptides allows for the design of vaccines with highly specific and predictable properties, and the role of dendrimers as carrier systems for vaccine antigens is increasing. In this work, we will focus on a review of the use of dendrimers in cancer diagnostics and therapy. Dendrimer-based nanosystems for drug delivery are commonly based on polyamidoamine dendrimers (PAMAM) that can be modified with drugs and contrast agents. Moreover, dendrimers can be successfully used as conjugates that deliver several substances simultaneously. The potential to develop dendrimers with multifunctional abilities has served as an impetus for the design of new molecular platforms for medical diagnostics and therapeutics.
Collapse
|
4
|
Mihailovic JM, Huang Y, Walsh JJ, Khan MH, Mishra SK, Samuels S, Hyder F, Coman D. High-resolution pH imaging using ratiometric chemical exchange saturation transfer combined with biosensor imaging of redundant deviation in shifts featuring paramagnetic DOTA-tetraglycinate agents. NMR IN BIOMEDICINE 2022; 35:e4658. [PMID: 34837412 DOI: 10.1002/nbm.4658] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 11/06/2021] [Accepted: 11/08/2021] [Indexed: 06/13/2023]
Abstract
Chemical exchange saturation transfer (CEST) and biosensor imaging of redundant deviation in shifts (BIRDS) methods differ respectively by detecting exchangeable and nonexchangeable proton signals by magnetic resonance. Because CEST contrast depends on both temperature and pH, simultaneous CEST and BIRDS imaging can be employed to separate these contributions. Here, we test if high-resolution pH imaging in vivo is possible with ratiometric CEST calibrated for temperature variations measured by BIRDS. Thulium- and europium-based DOTA-tetraglycinate agents, TmDOTA-(gly)4- and EuDOTA-(gly)4- , were used for high-resolution pH mapping in vitro and in vivo, using BIRDS for temperature adjustments needed for a more accurate ratiometric CEST approach. Although neither agent showed pH dependence with BIRDS in vitro in the pH range 6 to 8, each one's temperature sensitivity was enhanced when mixed because of increased redundancy. By contrast, the CEST signal of each agent was affected by the presence of the other agent in vitro. However, pH could be measured more accurately when temperature from BIRDS was detected. These in vitro calibrations with TmDOTA-(gly)4- and EuDOTA-(gly)4- enabled high-resolution pH imaging of glioblastoma in rat brains. It was concluded that temperature mapping with BIRDS can calibrate the ratiometric CEST signal from a cocktail of TmDOTA-(gly)4- and EuDOTA-(gly)4- agents to provide temperature-independent absolute pH imaging in vivo.
Collapse
Affiliation(s)
- Jelena M Mihailovic
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | - Yuegao Huang
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | - John J Walsh
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
| | - Muhammad H Khan
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
| | - Sandeep K Mishra
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | - Sara Samuels
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| | - Fahmeed Hyder
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
| | - Daniel Coman
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA
- Magnetic Resonance Research Center, Yale University, New Haven, Connecticut, USA
| |
Collapse
|
5
|
Khan MH, Mishra SK, Zakaria ABM, Mihailović JM, Coman D, Hyder F. Comparison of Lanthanide Macrocyclic Complexes as 23Na NMR Sensors. Anal Chem 2022; 94:2536-2545. [DOI: 10.1021/acs.analchem.1c04432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Muhammad H. Khan
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut 06520, United States
| | - Sandeep Kumar Mishra
- Department of Radiology & Biomedical Imaging, Yale University, New Haven, Connecticut 06520, United States
| | - A. B. M. Zakaria
- Department of Radiology & Biomedical Imaging, Yale University, New Haven, Connecticut 06520, United States
| | - Jelena M. Mihailović
- Department of Radiology & Biomedical Imaging, Yale University, New Haven, Connecticut 06520, United States
| | - Daniel Coman
- Department of Radiology & Biomedical Imaging, Yale University, New Haven, Connecticut 06520, United States
| | - Fahmeed Hyder
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut 06520, United States
- Department of Radiology & Biomedical Imaging, Yale University, New Haven, Connecticut 06520, United States
| |
Collapse
|
6
|
Walsh JJ, Parent M, Akif A, Adam LC, Maritim S, Mishra SK, Khan MH, Coman D, Hyder F. Imaging Hallmarks of the Tumor Microenvironment in Glioblastoma Progression. Front Oncol 2021; 11:692650. [PMID: 34513675 PMCID: PMC8426346 DOI: 10.3389/fonc.2021.692650] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 08/05/2021] [Indexed: 11/18/2022] Open
Abstract
Glioblastoma progression involves multifaceted changes in vascularity, cellularity, and metabolism. Capturing such complexities of the tumor niche, from the tumor core to the periphery, by magnetic resonance imaging (MRI) and spectroscopic imaging (MRSI) methods has translational impact. In human-derived glioblastoma models (U87, U251) we made simultaneous and longitudinal measurements of tumor perfusion (Fp), permeability (Ktrans), and volume fractions of extracellular (ve) and blood (vp) spaces from dynamic contrast enhanced (DCE) MRI, cellularity from apparent diffusion coefficient (ADC) MRI, and extracellular pH (pHe) from an MRSI method called Biosensor Imaging of Redundant Deviation in Shifts (BIRDS). Spatiotemporal patterns of these parameters during tumorigenesis were unique for each tumor. While U87 tumors grew faster, Fp, Ktrans, and vp increased with tumor growth in both tumors but these trends were more pronounced for U251 tumors. Perfused regions between tumor periphery and core with U87 tumors exhibited higher Fp, but Ktrans of U251 tumors remained lowest at the tumor margin, suggesting primitive vascularization. Tumor growth was uncorrelated with ve, ADC, and pHe. U87 tumors showed correlated regions of reduced ve and lower ADC (higher cellularity), suggesting ongoing proliferation. U251 tumors revealed that the tumor core had higher ve and elevated ADC (lower cellularity), suggesting necrosis development. The entire tumor was uniformly acidic (pHe 6.1-6.8) early and throughout progression, but U251 tumors were more acidic, suggesting lower aerobic glycolysis in U87 tumors. Characterizing these cancer hallmarks with DCE-MRI, ADC-MRI, and BIRDS-MRSI will be useful for exploring tumorigenesis as well as timely therapies targeted to specific vascular and metabolic aspects of the tumor microenvironment.
Collapse
Affiliation(s)
- John J Walsh
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
| | - Maxime Parent
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States.,Magnetic Resonance Research Center, Yale University, New Haven, CT, United States
| | - Adil Akif
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
| | - Lucas C Adam
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States.,Magnetic Resonance Research Center, Yale University, New Haven, CT, United States
| | - Samuel Maritim
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
| | - Sandeep K Mishra
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States.,Magnetic Resonance Research Center, Yale University, New Haven, CT, United States
| | - Muhammad H Khan
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States
| | - Daniel Coman
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States.,Magnetic Resonance Research Center, Yale University, New Haven, CT, United States
| | - Fahmeed Hyder
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States.,Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States.,Magnetic Resonance Research Center, Yale University, New Haven, CT, United States
| |
Collapse
|
7
|
Hyder F, Coman D. Imaging Extracellular Acidification and Immune Activation in Cancer. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2021; 18. [PMID: 33997581 DOI: 10.1016/j.cobme.2021.100278] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Metabolism reveals pathways by which cells, in healthy and disease tissues, use nutrients to fuel their function and (re)growth. However, gene-centric views have dominated cancer hallmarks, relegating metabolic reprogramming that all cells in the tumor niche undergo as an incidental phenomenon. Aerobic glycolysis in cancer is well known, but recent evidence suggests that diverse symbolic traits of cancer cells are derived from oncogene-directed metabolism required for their sustenance and evolution. Cells in the tumor milieu actively metabolize different nutrients, but proficiently secrete acidic by-products using diverse mechanisms to create a hostile ecosystem for host cells, and where local immune cells suffer collateral damage. Since metabolic interactions between cancer and immune cells hold promise for future cancer therapies, here we focus on translational magnetic resonance methods enabling in vivo and simultaneous detection of tumor habitat acidification and immune activation - innovations for monitoring personalized treatments.
Collapse
Affiliation(s)
- Fahmeed Hyder
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Department of Radiology & Biomedical Imaging, Yale University, New Haven, CT, USA
- Magnetic Resonance Research Center (MRRC), Yale University, New Haven, CT, USA
- Quantitative Neuroimaging with Magnetic Resonance (QNMR) Research Program, Yale University, New Haven, CT, USA
| | - Daniel Coman
- Department of Radiology & Biomedical Imaging, Yale University, New Haven, CT, USA
- Magnetic Resonance Research Center (MRRC), Yale University, New Haven, CT, USA
| |
Collapse
|
8
|
Chen JS, Chen J, Bhattacharjee S, Cao Z, Wang H, Swanson SD, Zong H, Baker JR, Wang SH. Functionalized nanoparticles with targeted antibody to enhance imaging of breast cancer in vivo. J Nanobiotechnology 2020; 18:135. [PMID: 32948179 PMCID: PMC7501678 DOI: 10.1186/s12951-020-00695-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Accepted: 09/09/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Targeted contrast nanoparticles for breast tumor imaging facilitates early detection and improves treatment efficacy of breast cancer. This manuscript reports the development of an epidermal growth factor receptor-2 (HER-2) specific, bi-modal, dendrimer conjugate to enhance computed tomography (CT) and magnetic resonance imaging (MRI) of HER-2-positive breast cancer. This material employs generation 5 poly(amidoamine) dendrimers, encapsulated gold nanoparticles, chelated gadolinium, and anti-human HER-2 antibody to produce the nanoparticle contrast agent. RESULTS Testing in two mouse tumor models confirms this contrast agent's ability to image HER-2 positive tumors. Intravenous injection of this nanoparticle in mice bearing HER-2 positive mammary tumors significantly enhances MRI signal intensity by ~ 20% and improves CT resolution and contrast by two-fold. Results by flow cytometry and confocal microscopy validate the specific targeting of the conjugate and its internalization in human HER-2 positive cells. CONCLUSION These results demonstrate that this nanoparticle conjugate can efficiently target and image HER-2 positive tumors in vivo and provide a basis for the development of this diagnostic tool for early detection, metastatic assessment and therapeutic monitoring of HER-2 positive cancers.
Collapse
Affiliation(s)
- Jesse S Chen
- Department of Internal Medicine, Division of Allergy, Michigan Nanotechnology Institute for Medicine and Biological Sciences, University of Michigan, 109 Zina Pitcher Place, Ann Arbor, MI, 48109, USA
| | - Jingwen Chen
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Somnath Bhattacharjee
- Department of Internal Medicine, Division of Allergy, Michigan Nanotechnology Institute for Medicine and Biological Sciences, University of Michigan, 109 Zina Pitcher Place, Ann Arbor, MI, 48109, USA
| | - Zhengyi Cao
- Department of Internal Medicine, Division of Allergy, Michigan Nanotechnology Institute for Medicine and Biological Sciences, University of Michigan, 109 Zina Pitcher Place, Ann Arbor, MI, 48109, USA
| | - Han Wang
- Department of Radiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Scott D Swanson
- Department of Radiology, University of Michigan, 1500 East Medical Center Drive, Ann Arbor, MI, 48109, USA
| | - Hong Zong
- Department of Internal Medicine, Division of Allergy, Michigan Nanotechnology Institute for Medicine and Biological Sciences, University of Michigan, 109 Zina Pitcher Place, Ann Arbor, MI, 48109, USA
| | - James R Baker
- Department of Internal Medicine, Division of Allergy, Michigan Nanotechnology Institute for Medicine and Biological Sciences, University of Michigan, 109 Zina Pitcher Place, Ann Arbor, MI, 48109, USA
| | - Su He Wang
- Department of Internal Medicine, Division of Allergy, Michigan Nanotechnology Institute for Medicine and Biological Sciences, University of Michigan, 109 Zina Pitcher Place, Ann Arbor, MI, 48109, USA.
| |
Collapse
|
9
|
Carvalho MR, Reis RL, Oliveira JM. Dendrimer nanoparticles for colorectal cancer applications. J Mater Chem B 2020; 8:1128-1138. [PMID: 31971528 DOI: 10.1039/c9tb02289a] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Cancer nanotechnology is a prolific field of research, where nanotools are employed to diagnose and treat cancer with unprecedented precision. Targeted drug delivery is fundamental for more efficient cancer treatments. For this, nanoparticles have been extensively used during the past few years in order to improve the specificity, selectivity and controlled release of drug delivery. It holds potential in minimizing systemic toxicity through the development of functionalized particles for targeted treatment. Among all the type of nanoparticles, dendrimers display several advantages, which make them ideal candidates for improved and targeted drug delivery in cancer research. Dendrimers can transport large amounts of drug into specific areas. In addition, they can be employed for monitoring the progress of the treatment process, with an unprecedented theranostic capability. Special emphasis is given to colorectal cancer and to the preferred employed strategies for producing drug-loaded/functionalized NPs for cancer therapy in the past few years.
Collapse
Affiliation(s)
- M R Carvalho
- 3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal. and ICVS/3B's - PT Government Associate Laboratory, Braga/Guimarães, Portugal and The Discoveries Centre for Regenerative and Precision Medicine, Headquarters at University of Minho, Guimarães, Portugal
| | - R L Reis
- 3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal. and ICVS/3B's - PT Government Associate Laboratory, Braga/Guimarães, Portugal and The Discoveries Centre for Regenerative and Precision Medicine, Headquarters at University of Minho, Guimarães, Portugal
| | - J M Oliveira
- 3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal. and ICVS/3B's - PT Government Associate Laboratory, Braga/Guimarães, Portugal and The Discoveries Centre for Regenerative and Precision Medicine, Headquarters at University of Minho, Guimarães, Portugal
| |
Collapse
|
10
|
|
11
|
Molecular Imaging with 68Ga Radio-Nanomaterials: Shedding Light on Nanoparticles. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8071098] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
12
|
Lee MY, Choi D, Jang MS, Lee JH. Biocompatible and Biodegradable Fe3+–Melanoidin Chelate as a Potentially Safe Contrast Agent for Liver MRI. Bioconjug Chem 2018; 29:2426-2435. [DOI: 10.1021/acs.bioconjchem.8b00331] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Min-Young Lee
- Smart Healthcare Medical Device Research Center, Samsung Medical Center, 81, Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
- Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
| | - Dongil Choi
- Smart Healthcare Medical Device Research Center, Samsung Medical Center, 81, Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
- Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81, Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
| | - Moon-Sun Jang
- Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81, Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
| | - Jung Hee Lee
- Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81, Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
| |
Collapse
|
13
|
Mahara A, Enmi JI, Hsu YI, Kobayashi N, Hirano Y, Iida H, Yamaoka T. Superfine Magnetic Resonance Imaging of the Cerebrovasculature Using Self-Assembled Branched Polyethylene Glycol-Gd Contrast Agent. Macromol Biosci 2018; 18:e1700391. [PMID: 29665311 DOI: 10.1002/mabi.201700391] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 02/15/2018] [Indexed: 12/12/2022]
Abstract
Magnetic resonance angiography is an attractive method for the visualization of the cerebrovasculature, but small-sized vessels are hard to visualize with the current clinically approved agents. In this study, a polymeric contrast agent for the superfine imaging of the cerebrovasculature is presented. Eight-arm polyethylene glycol with a molecular weight of ≈17 000 Da conjugated with a Gd chelate and fluorescein (F-8-arm PEG-Gd) is used. The relaxivity rate is 9.3 × 10-3 m-1 s-1 , which is threefold higher than that of free Gd chelate. Light scattering analysis reveals that F-8-arm PEG-Gd is formed by self-assembly. When the F-8-arm PEG-Gd is intravenously injected, cerebrovasculature as small as 100 µm in diameter is clearly visualized. However, signals are not enhanced when Gd chelate and Gd chelate-conjugated 8-arm PEG are injected. Furthermore, small vasculature around infarct region in rat stroke model can be visualized. These results suggest that F-8-arm PEG-Gd enhances the MR imaging of cerebrovasculature.
Collapse
Affiliation(s)
- Atsushi Mahara
- Department of Biomedical Engineering, National Cerebral and Cardiovascular Center Research Institute, Fujishiro-dai, Suita, Osaka, 565-8565, Japan
| | - Jun-Ichiro Enmi
- Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, Fujishiro-dai, Suita, Osaka, 565-8565, Japan
| | - Yu-I Hsu
- Department of Biomedical Engineering, National Cerebral and Cardiovascular Center Research Institute, Fujishiro-dai, Suita, Osaka, 565-8565, Japan
| | - Naoki Kobayashi
- Faculty of Chemistry, Materials and Bioengineering, Kansai University, 3-3-35 Yamatecho, Suita, Osaka, 565-8680, Japan
| | - Yoshiaki Hirano
- Faculty of Chemistry, Materials and Bioengineering, Kansai University, 3-3-35 Yamatecho, Suita, Osaka, 565-8680, Japan
| | - Hidehiro Iida
- Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, Fujishiro-dai, Suita, Osaka, 565-8565, Japan
| | - Tetsuji Yamaoka
- Department of Biomedical Engineering, National Cerebral and Cardiovascular Center Research Institute, Fujishiro-dai, Suita, Osaka, 565-8565, Japan
| |
Collapse
|
14
|
Abstract
Metabolism is central to neuroimaging because it can reveal pathways by which neuronal and glial cells use nutrients to fuel their growth and function. We focus on advanced magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) methods used in brain metabolic studies. 17O-MRS and 31P-MRS, respectively, provide rates of oxygen use and ATP synthesis inside mitochondria, whereas 19F-MRS enables measurement of cytosolic glucose metabolism. Calibrated functional MRI (fMRI), an advanced form of fMRI that uses contrast generated by deoxyhemoglobin, provides maps of oxygen use that track neuronal firing across brain regions. 13C-MRS is the only noninvasive method of measuring both glutamatergic neurotransmission and cell-specific energetics with signaling and nonsignaling purposes. Novel MRI contrasts, arising from endogenous diamagnetic agents and exogenous paramagnetic agents, permit pH imaging of glioma. Overall, these magnetic resonance methods for imaging brain metabolism demonstrate translational potential to better understand brain disorders and guide diagnosis and treatment.
Collapse
Affiliation(s)
- Fahmeed Hyder
- Department of Biomedical Engineering, Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, and Quantitative Neuroscience with Magnetic Resonance Core Center, Yale University, New Haven, Connecticut 06520;
| | - Douglas L Rothman
- Department of Biomedical Engineering, Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, and Quantitative Neuroscience with Magnetic Resonance Core Center, Yale University, New Haven, Connecticut 06520;
| |
Collapse
|
15
|
Brain Tumor Diagnostics and Therapeutics with Superparamagnetic Ferrite Nanoparticles. CONTRAST MEDIA & MOLECULAR IMAGING 2017; 2017:6387217. [PMID: 29375280 PMCID: PMC5742516 DOI: 10.1155/2017/6387217] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 09/24/2017] [Indexed: 11/18/2022]
Abstract
Ferrite nanoparticles (F-NPs) can transform both cancer diagnostics and therapeutics. Superparamagnetic F-NPs exhibit high magnetic moment and susceptibility such that in presence of a static magnetic field transverse relaxation rate of water protons for MRI contrast is augmented to locate F-NPs (i.e., diagnostics) and exposed to an alternating magnetic field local temperature is increased to induce tissue necrosis (i.e., thermotherapy). F-NPs are modified by chemical synthesis of mixed spinel ferrites as well as their size, shape, and coating. Purposely designed drug-containing nanoparticles (D-NPs) can slowly deliver drugs (i.e., chemotherapy). Convection-enhanced delivery (CED) of D-NPs with MRI guidance improves glioblastoma multiforme (GBM) treatment. MRI monitors the location of chemotherapy when D-NPs and F-NPs are coadministered with CED. However superparamagnetic field gradients produced by F-NPs complicate MRI readouts (spatial distortions) and MRS (extensive line broadening). Since extracellular pH (pHe) is a cancer hallmark, pHe imaging is needed to screen cancer treatments. Biosensor imaging of redundant deviation in shifts (BIRDS) extrapolates pHe from paramagnetically shifted signals and the pHe accuracy remains unaffected by F-NPs. Hence effect of both chemotherapy and thermotherapy can be monitored (by BIRDS), whereas location of F-NPs is revealed (by MRI). Smarter tethering of nanoparticles and agents will impact GBM theranostics.
Collapse
|
16
|
Pellico J, Llop J, Fernández-Barahona I, Bhavesh R, Ruiz-Cabello J, Herranz F. Iron Oxide Nanoradiomaterials: Combining Nanoscale Properties with Radioisotopes for Enhanced Molecular Imaging. CONTRAST MEDIA & MOLECULAR IMAGING 2017; 2017:1549580. [PMID: 29358900 PMCID: PMC5735613 DOI: 10.1155/2017/1549580] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 10/01/2017] [Indexed: 12/12/2022]
Abstract
The combination of the size-dependent properties of nanomaterials with radioisotopes is emerging as a novel tool for molecular imaging. There are numerous examples already showing how the controlled synthesis of nanoparticles and the incorporation of a radioisotope in the nanostructure offer new features beyond the simple addition of different components. Among the different nanomaterials, iron oxide-based nanoparticles are the most used in imaging because of their versatility. In this review, we will study the different radioisotopes for biomedical imaging, how to incorporate them within the nanoparticles, and what applications they can be used for. Our focus is directed towards what is new in this field, what the nanoparticles can offer to the field of nuclear imaging, and the radioisotopes hybridized with nanomaterials for use in molecular imaging.
Collapse
Affiliation(s)
- Juan Pellico
- Centro Nacional de Investigaciones Cardiovasculares Carlos III (CNIC) and Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES), 28029 Madrid, Spain
| | - Jordi Llop
- Radiochemistry and Nuclear Imaging Group, CIC biomaGUNE, Paseo Miramon 182, 20009 Donostia, Spain
| | - Irene Fernández-Barahona
- Centro Nacional de Investigaciones Cardiovasculares Carlos III (CNIC) and Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES), 28029 Madrid, Spain
| | - Riju Bhavesh
- Centro Nacional de Investigaciones Cardiovasculares Carlos III (CNIC) and Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES), 28029 Madrid, Spain
| | - Jesús Ruiz-Cabello
- Departamento Química Física II, Facultad de Farmacia, Universidad Complutense de Madrid, 28040 Madrid, Spain
- Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES), 28029 Madrid, Spain
| | - Fernando Herranz
- Centro Nacional de Investigaciones Cardiovasculares Carlos III (CNIC) and Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES), 28029 Madrid, Spain
| |
Collapse
|
17
|
Anwaier G, Chen C, Cao Y, Qi R. A review of molecular imaging of atherosclerosis and the potential application of dendrimer in imaging of plaque. Int J Nanomedicine 2017; 12:7681-7693. [PMID: 29089763 PMCID: PMC5656339 DOI: 10.2147/ijn.s142385] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Despite the fact that technological advancements have been made in diagnosis and treatment, cardiovascular diseases (CVDs) remain the leading cause of mortality and morbidity worldwide. Early detection of atherosclerosis (AS), especially vulnerable plaques, plays a crucial role in the prevention of acute coronary syndrome (ACS). Targeting the critical cytokines and molecules that are upregulated during the biological process of AS by in vivo molecular imaging has been widely used in plaque imaging. With their three-dimensional architecture, composition, and abundant terminal functional groups, dendrimers provide a platform for multitargeting and multimodal imaging. Thus, modified dendrimers with the key molecules upregulated in AS plaques will be an innovative attempt to achieve targeted imaging of AS plaques specifically and efficiently. This review was aimed to address some recent works on imaging of AS plaques using various types of image technology and further discuss the applications of dendrimers, an innovative yet seldom used method in imaging of AS plaques due to some limitations and challenges, and we highlight the bright future of the modified dendrimers in characterizing AS plaques.
Collapse
Affiliation(s)
- Gulinigaer Anwaier
- Peking University Institute of Cardiovascular Sciences, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of education, Peking University Health Science Center.,Beijing Key Laboratory of Molecular Pharmaceutics and New Drug Delivery Systems, Beijing.,School of Basic Medical Science, Shihezi University, Shihezi, Xinjiang, People's Republic of China
| | - Cong Chen
- Peking University Institute of Cardiovascular Sciences, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of education, Peking University Health Science Center.,Beijing Key Laboratory of Molecular Pharmaceutics and New Drug Delivery Systems, Beijing
| | - Yini Cao
- Peking University Institute of Cardiovascular Sciences, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of education, Peking University Health Science Center.,Beijing Key Laboratory of Molecular Pharmaceutics and New Drug Delivery Systems, Beijing
| | - Rong Qi
- Peking University Institute of Cardiovascular Sciences, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of education, Peking University Health Science Center.,Beijing Key Laboratory of Molecular Pharmaceutics and New Drug Delivery Systems, Beijing.,School of Basic Medical Science, Shihezi University, Shihezi, Xinjiang, People's Republic of China
| |
Collapse
|
18
|
Franiak-Pietryga I, Maciejewski H, Ziemba B, Appelhans D, Voit B, Robak T, Jander M, Treliński J, Bryszewska M, Borowiec M. Blockage of Wnt/β-Catenin Signaling by Nanoparticles Reduces Survival and Proliferation of CLL Cells In Vitro-Preliminary Study. Macromol Biosci 2017; 17. [DOI: 10.1002/mabi.201700130] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2017] [Revised: 06/19/2017] [Indexed: 12/12/2022]
Affiliation(s)
- Ida Franiak-Pietryga
- Department of Clinical and Laboratory Genetics; Medical University of Lodz; Pomorska Str. 251 92-213 Lodz Poland
- Laboratory of Clinical and Transplant Immunology and Genetics; Copernicus Memorial Hospital; Pabianicka Str. 62 93-513 Lodz Poland
- GeneaMed LTD; Kopcinskiego Str. 16/18/904 90-232 Lodz Poland
| | - Henryk Maciejewski
- Department of Computer Engineering; Wroclaw University of Technology; Janiszewskiego Str. 11/17 50-372 Wroclaw Poland
| | - Barbara Ziemba
- Department of Clinical and Laboratory Genetics; Medical University of Lodz; Pomorska Str. 251 92-213 Lodz Poland
| | - Dietmar Appelhans
- Leibniz Institute of Polymer Research Dresden; Hohe Str. 6 D-01069 Dresden Germany
| | - Brigitte Voit
- Leibniz Institute of Polymer Research Dresden; Hohe Str. 6 D-01069 Dresden Germany
| | - Tadeusz Robak
- Department of Hematology; Medical University of Lodz; Copernicus Memorial Hospital; Pabianicka Str. 62 93-513 Lodz Poland
| | | | - Jacek Treliński
- Department of Hematology; Medical University of Lodz; Copernicus Memorial Hospital; Pabianicka Str. 62 93-513 Lodz Poland
| | - Maria Bryszewska
- Department of General Biophysics; Faculty of Biology and Environmental Protection; University of Lodz; Pomorska Str. 141/143 90-236 Lodz Poland
| | - Maciej Borowiec
- Department of Clinical and Laboratory Genetics; Medical University of Lodz; Pomorska Str. 251 92-213 Lodz Poland
| |
Collapse
|
19
|
Zhang L, Varma NR, Gang ZZ, Ewing JR, Arbab AS, Ali MM. Targeting Triple Negative Breast Cancer with a Small-sized Paramagnetic Nanoparticle. ACTA ACUST UNITED AC 2016; 7. [PMID: 28018751 DOI: 10.4172/2157-7439.1000404] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
There is no available targeted therapy or imaging agent for triple negative breast cancer (TNBC). We developed a small-sized dendrimer-based nanoparticle containing a clinical relevant MRI contrast agent, GdDOTA and a NIR fluorescent dye, DL680. Systemic delivery of dual-modal nanoparticles led to accumulation of the agents in a flank mouse model of TNBC that were detected by both optical and MR imaging. In-vivo fluorescence images, as well as ex-vivo fluorescence images of individual organs, demonstrated that nanoparticles accumulated into tumor selectively. A dual modal strategy resulted in a selective delivery of a small-sized (GdDOTA)42-G4-DL680 dendrimeric agent to TNBC tumors, avoiding other major organs.
Collapse
Affiliation(s)
- Li Zhang
- Department of Neurology, Henry Ford Hospital, Detroit, MI 48202, USA
| | | | - Zhang Z Gang
- Department of Neurology, Henry Ford Hospital, Detroit, MI 48202, USA
| | - James R Ewing
- Department of Neurology, Henry Ford Hospital, Detroit, MI 48202, USA
| | - Ali S Arbab
- Tumor Angiogenesis Laboratory, Georgia Cancer Center, Augusta University, Augusta, GA, USA
| | - Meser M Ali
- Department of Neurology, Henry Ford Hospital, Detroit, MI 48202, USA
| |
Collapse
|
20
|
Huang Y, Coman D, Herman P, Rao JU, Maritim S, Hyder F. Towards longitudinal mapping of extracellular pH in gliomas. NMR IN BIOMEDICINE 2016; 29:1364-1372. [PMID: 27472471 PMCID: PMC5035200 DOI: 10.1002/nbm.3578] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2016] [Revised: 06/06/2016] [Accepted: 06/07/2016] [Indexed: 06/06/2023]
Abstract
Biosensor imaging of redundant deviation in shifts (BIRDS), an ultrafast chemical shift imaging technique, requires infusion of paramagnetic probes such as 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetrakis methylene phosphonate (DOTP(8-) ) complexed with thulium (Tm(3+) ) ion (i.e. TmDOTP(5-) ), where the pH-sensitive resonances of hyperfine-shifted non-exchangeable protons contained within the paramagnetic probe are detected. While imaging extracellular pH (pHe ) with BIRDS meets an important cancer research need by mapping the intratumoral-peritumoral pHe gradient, the surgical intervention used to raise the probe's plasma concentration limits longitudinal scans on the same subject. Here we describe using probenecid (i.e. an organic anion transporter inhibitor) to temporarily restrict renal clearance of TmDOTP(5-) , thereby facilitating molecular imaging by BIRDS without surgical intervention. Co-infusion of probenecid with TmDOTP(5-) increased the probe's distribution into various organs, including the brain, compared with infusing TmDOTP(5-) alone. In vivo BIRDS data using the probenecid-TmDOTP(5-) co-infusion method in rats bearing RG2, 9 L, and U87 brain tumors showed intratumoral-peritumoral pHe gradients that were unaffected by the probe dose. This co-infusion method can be used for pHe mapping with BIRDS in preclinical models for tumor characterization and therapeutic monitoring, given the possibility of repeated scans with BIRDS (e.g. over days and even weeks) in the same subject. The longitudinal pHe readout by the probenecid-TmDOTP(5-) co-infusion method for BIRDS adds translational value in tumor assessment and treatment. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Yuegao Huang
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA.
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.
| | - Daniel Coman
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| | - Peter Herman
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| | - Jyotsna U Rao
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| | - Samuel Maritim
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Fahmeed Hyder
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA.
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
| |
Collapse
|
21
|
Karki K, Ewing JR, Ali MM. Targeting Glioma with a Dual Mode Optical and Paramagnetic Nanoprobe across the Blood-brain Tumor Barrier. ACTA ACUST UNITED AC 2016; 7. [PMID: 27695645 PMCID: PMC5042151 DOI: 10.4172/2157-7439.1000395] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
In brain tumors, delivering nanoparticles across the blood-tumor barrier presents major hurdles. A clinically relevant MRI contrast agent, GdDOTA and a near-infrared (NIR) fluorescent dye, DL680 were conjugated to a G5 PAMAM dendrimer, thus producing a dual-mode MRI and NIR imaging agent. Systemic delivery of the subsequent nano-sized agent demonstrated glioma-specific accumulation, probably due to the enhanced permeability and retention effect. In vivo MRI detected the agent in glioma tissue, but not in normal contralateral tissue; this observation was validated with in vivo and ex vivo fluorescence imaging. A biodistribution study showed the agent to have accumulated in the glioma tumor and the liver, the latter being the excretion path for a G5 dendrimer-based agent.
Collapse
Affiliation(s)
- Kishor Karki
- Department of Neurology, Henry Ford Hospital, Detroit, MI 48202, USA
| | - James R Ewing
- Department of Neurology, Henry Ford Hospital, Detroit, MI 48202, USA
| | - Meser M Ali
- Department of Neurology, Henry Ford Hospital, Detroit, MI 48202, USA
| |
Collapse
|
22
|
Coman D, Huang Y, Rao JU, De Feyter HM, Rothman DL, Juchem C, Hyder F. Imaging the intratumoral-peritumoral extracellular pH gradient of gliomas. NMR IN BIOMEDICINE 2016; 29:309-19. [PMID: 26752688 PMCID: PMC4769673 DOI: 10.1002/nbm.3466] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 11/19/2015] [Accepted: 11/19/2015] [Indexed: 05/26/2023]
Abstract
Solid tumors have an acidic extracellular pH (pHe ) but near neutral intracellular pH (pHi ). Because acidic pHe milieu is conducive to tumor growth and builds resistance to therapy, simultaneous mapping of pHe inside and outside the tumor (i.e., intratumoral-peritumoral pHe gradient) fulfills an important need in cancer imaging. We used Biosensor Imaging of Redundant Deviation in Shifts (BIRDS), which utilizes shifts of non-exchangeable protons from macrocyclic chelates (e.g., 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetrakis(methylene phosphonate) or DOTP(8-) ) complexed with paramagnetic thulium (Tm(3) (+) ) ion, to generate in vivo pHe maps in rat brains bearing 9L and RG2 tumors. Upon TmDOTP(5-) infusion, MRI identified the tumor boundary by enhanced water transverse relaxation and BIRDS allowed imaging of intratumoral-peritumoral pHe gradients. The pHe measured by BIRDS was compared with pHi measured with (31) P-MRS. In normal tissue, pHe was similar to pHi , but inside the tumor pHe was lower than pHi . While the intratumoral pHe was acidic for both tumor types, peritumoral pHe varied with tumor type. The intratumoral-peritumoral pHe gradient was much larger for 9L than RG2 tumors because in RG2 tumors acidic pHe was found in distal peritumoral regions. The increased presence of Ki-67 positive cells beyond the RG2 tumor border suggested that RG2 was more invasive than the 9L tumor. These results indicate that extensive acidic pHe beyond the tumor boundary correlates with tumor cell invasion. In summary, BIRDS has sensitivity to map the in vivo intratumoral-peritumoral pHe gradient, thereby creating preclinical applications in monitoring cancer therapeutic responses (e.g., with pHe -altering drugs). Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Daniel Coman
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT, USA
| | - Yuegao Huang
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT, USA
| | - Jyotsna U. Rao
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT, USA
| | - Henk M. De Feyter
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT, USA
| | - Douglas L. Rothman
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT, USA
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Christoph Juchem
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT, USA
- Department of Neurology, Yale University, New Haven, CT, USA
| | - Fahmeed Hyder
- Magnetic Resonance Research Center, Yale University, New Haven, CT, USA
- Department of Diagnostic Radiology, Yale University, New Haven, CT, USA
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| |
Collapse
|