1
|
Hu C, Wang Y, Lee YM. Ether-Free Alkaline Polyelectrolytes for Water Electrolyzers: Recent Advances and Perspectives. Angew Chem Int Ed Engl 2025; 64:e202418324. [PMID: 39485307 DOI: 10.1002/anie.202418324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2024] [Revised: 10/31/2024] [Accepted: 11/01/2024] [Indexed: 11/03/2024]
Abstract
Anion exchange membrane (AEM) water electrolyzers (AEMWEs) have attracted great interest for their potential as sustainable, environmentally friendly, low-cost sources of renewable energy. Alkaline polyelectrolytes play a crucial role in AEMWEs, determining their performance and longevity. Because heteroatom-containing polymers have been shown to have poor durability in alkaline conditions, this review focuses on ether-free alkaline polyelectrolytes, which are more chemically stable. The merits, weaknesses, and challenges in preparing ether-free AEMs are summarized and highlighted. The evaluation of synthesis methods for polymers, modification strategies, and cationic stability will provide insights valuable for the structural design of future alkaline polyelectrolytes. Moreover, the in situ degradation mechanisms of AEMs and ionomers during AEMWE operation are revealed. This review provides insights into the design of alkaline polyelectrolytes for AEMWEs to accelerate their widespread commercialization.
Collapse
Affiliation(s)
- Chuan Hu
- Department of Energy Engineering, College of Engineering, Hanyang University, Seoul, 04763, Republic of Korea
- School of Energy and Environment, Southeast University, No. 2, Southeast University Road, Jiangning District, Nanjing, Jiangsu Province, China
| | - Yong Wang
- School of Energy and Environment, Southeast University, No. 2, Southeast University Road, Jiangning District, Nanjing, Jiangsu Province, China
| | - Young Moo Lee
- Department of Energy Engineering, College of Engineering, Hanyang University, Seoul, 04763, Republic of Korea
| |
Collapse
|
2
|
Henkensmeier D, Cho WC, Jannasch P, Stojadinovic J, Li Q, Aili D, Jensen JO. Separators and Membranes for Advanced Alkaline Water Electrolysis. Chem Rev 2024; 124:6393-6443. [PMID: 38669641 PMCID: PMC11117188 DOI: 10.1021/acs.chemrev.3c00694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 01/23/2024] [Accepted: 04/01/2024] [Indexed: 04/28/2024]
Abstract
Traditionally, alkaline water electrolysis (AWE) uses diaphragms to separate anode and cathode and is operated with 5-7 M KOH feed solutions. The ban of asbestos diaphragms led to the development of polymeric diaphragms, which are now the state of the art material. A promising alternative is the ion solvating membrane. Recent developments show that high conductivities can also be obtained in 1 M KOH. A third technology is based on anion exchange membranes (AEM); because these systems use 0-1 M KOH feed solutions to balance the trade-off between conductivity and the AEM's lifetime in alkaline environment, it makes sense to treat them separately as AEM WE. However, the lifetime of AEM increased strongly over the last 10 years, and some electrode-related issues like oxidation of the ionomer binder at the anode can be mitigated by using KOH feed solutions. Therefore, AWE and AEM WE may get more similar in the future, and this review focuses on the developments in polymeric diaphragms, ion solvating membranes, and AEM.
Collapse
Affiliation(s)
- Dirk Henkensmeier
- Hydrogen
· Fuel Cell Research Center, Korea
Institute of Science and Technology, Seoul 02792, Republic of Korea
- Division
of Energy & Environment Technology, KIST School, University of Science and Technology, Seoul 02792, Republic of Korea
- KU-KIST
Green School, Korea University, Seoul 02841, Republic of Korea
| | - Won-Chul Cho
- Department
of Future Energy Convergence, Seoul National
University of Science & Technology, 232 Gongreung-ro, Nowon-gu, Seoul 01811, Korea
| | - Patric Jannasch
- Polymer
& Materials Chemistry, Department of Chemistry, Lund University, 221 00 Lund, Sweden
| | | | - Qingfeng Li
- Department
of Energy Conversion and Storage, Technical
University of Denmark (DTU), Fysikvej 310, 2800 Kgs. Lyngby, Denmark
| | - David Aili
- Department
of Energy Conversion and Storage, Technical
University of Denmark (DTU), Fysikvej 310, 2800 Kgs. Lyngby, Denmark
| | - Jens Oluf Jensen
- Department
of Energy Conversion and Storage, Technical
University of Denmark (DTU), Fysikvej 310, 2800 Kgs. Lyngby, Denmark
| |
Collapse
|
3
|
Hu C, Kang HW, Jung SW, Liu ML, Lee YJ, Park JH, Kang NY, Kim MG, Yoo SJ, Park CH, Lee YM. High Free Volume Polyelectrolytes for Anion Exchange Membrane Water Electrolyzers with a Current Density of 13.39 A cm -2 and a Durability of 1000 h. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2306988. [PMID: 38044283 PMCID: PMC10837377 DOI: 10.1002/advs.202306988] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 11/12/2023] [Indexed: 12/05/2023]
Abstract
The rational design of the current anion exchange polyelectrolytes (AEPs) is challenging to meet the requirements of both high performance and durability in anion exchange membrane water electrolyzers (AEMWEs). Herein, highly-rigid-twisted spirobisindane monomer is incorporated in poly(aryl-co-aryl piperidinium) backbone to construct continuous ionic channels and to maintain dimensional stability as promising materials for AEPs. The morphologies, physical, and electrochemical properties of the AEPs are investigated based on experimental data and molecular dynamics simulations. The present AEPs possess high free volumes, excellent dimensional stability, hydroxide conductivity (208.1 mS cm-1 at 80 °C), and mechanical properties. The AEMWE of the present AEPs achieves a new current density record of 13.39 and 10.7 A cm-2 at 80 °C by applying IrO2 and nonprecious anode catalyst, respectively, along with outstanding in situ durability under 1 A cm-2 for 1000 h with a low voltage decay rate of 53 µV h-1 . Moreover, the AEPs can be applied in fuel cells and reach a power density of 2.02 W cm-2 at 80 °C under fully humidified conditions, and 1.65 W cm-2 at 100 °C, 30% relative humidity. This study provides insights into the design of high-performance AEPs for energy conversion devices.
Collapse
Affiliation(s)
- Chuan Hu
- Department of Energy Engineering, College of Engineering, Hanyang University, Seoul, 04763, Republic of Korea
| | - Hyun Woo Kang
- Department of Energy Engineering, Future Convergence Technology Research Institute, Gyeongsang National University, Jinju, 52725, Republic of Korea
| | - Seung Won Jung
- Department of Energy Engineering, College of Engineering, Hanyang University, Seoul, 04763, Republic of Korea
| | - Mei-Ling Liu
- Department of Energy Engineering, College of Engineering, Hanyang University, Seoul, 04763, Republic of Korea
| | - Young Jun Lee
- Department of Energy Engineering, College of Engineering, Hanyang University, Seoul, 04763, Republic of Korea
| | - Jong Hyeong Park
- Department of Energy Engineering, College of Engineering, Hanyang University, Seoul, 04763, Republic of Korea
| | - Na Yoon Kang
- Department of Energy Engineering, College of Engineering, Hanyang University, Seoul, 04763, Republic of Korea
| | - Myeong-Geun Kim
- Hydrogen Fuel Cell Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Sung Jong Yoo
- Hydrogen Fuel Cell Research Center, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Chi Hoon Park
- Department of Energy Engineering, Future Convergence Technology Research Institute, Gyeongsang National University, Jinju, 52725, Republic of Korea
| | - Young Moo Lee
- Department of Energy Engineering, College of Engineering, Hanyang University, Seoul, 04763, Republic of Korea
| |
Collapse
|
4
|
Roggi A, Guazzelli E, Resta C, Agonigi G, Filpi A, Martinelli E. Vinylbenzyl Chloride/Styrene-Grafted SBS Copolymers via TEMPO-Mediated Polymerization for the Fabrication of Anion Exchange Membranes for Water Electrolysis. Polymers (Basel) 2023; 15:polym15081826. [PMID: 37111973 PMCID: PMC10144011 DOI: 10.3390/polym15081826] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/31/2023] [Accepted: 04/04/2023] [Indexed: 04/29/2023] Open
Abstract
In this work, a commercial SBS was functionalized with the 2,2,6,6-tetramethylpiperidin-N-oxyl stable radical (TEMPO) via free-radical activation initiated with benzoyl peroxide (BPO). The obtained macroinitiator was used to graft both vinylbenzyl chloride (VBC) and styrene/VBC random copolymer chains from SBS to create g-VBC-x and g-VBC-x-co-Sty-z graft copolymers, respectively. The controlled nature of the polymerization as well as the use of a solvent allowed us to reduce the extent of the formation of the unwanted, non-grafted (co)polymer, thereby facilitating the graft copolymer's purification. The obtained graft copolymers were used to prepare films via solution casting using chloroform. The -CH2Cl functional groups of the VBC grafts were then quantitatively converted to -CH2(CH3)3N+ quaternary ammonium groups via reaction with trimethylamine directly on the films, and the films, therefore, were investigated as anion exchange membranes (AEMs) for potential application in a water electrolyzer (WE). The membranes were extensively characterized to assess their thermal, mechanical, and ex situ electrochemical properties. They generally presented ionic conductivity comparable to or higher than that of a commercial benchmark as well as higher water uptake and hydrogen permeability. Interestingly, the styrene/VBC-grafted copolymer was found to be more mechanically resistant than the corresponding graft copolymer not containing the styrene component. For this reason, the copolymer g-VBC-5-co-Sty-16-Q with the best balance of mechanical, water uptake, and electrochemical properties was selected for a single-cell test in an AEM-WE.
Collapse
Affiliation(s)
- Andrea Roggi
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Moruzzi 13, 56126 Pisa, Italy
| | - Elisa Guazzelli
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Moruzzi 13, 56126 Pisa, Italy
| | - Claudio Resta
- Enapter s.r.l., Crespina-Lorenzana (Pisa), 56040 Pisa, Italy
| | | | - Antonio Filpi
- Enapter s.r.l., Crespina-Lorenzana (Pisa), 56040 Pisa, Italy
| | - Elisa Martinelli
- Department of Chemistry and Industrial Chemistry, University of Pisa, Via Moruzzi 13, 56126 Pisa, Italy
| |
Collapse
|
5
|
Xue J, Zhang J, Liu X, Huang T, Jiang H, Yin Y, Qin Y, Guiver MD. Toward alkaline-stable anion exchange membranes in fuel cells: cycloaliphatic quaternary ammonium-based anion conductors. ELECTROCHEM ENERGY R 2021. [DOI: 10.1007/s41918-021-00105-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
6
|
Wang L, You R, Ling Y, Xie Y, Mei C, Li Z, Wang F. Covalent cross-linked anion exchange membrane based on poly(biphenyl piperidine) and poly(styrene-b-(ethylene-co-butylene)-b-styrene): preparation and properties. POLYM-PLAST TECH MAT 2021. [DOI: 10.1080/25740881.2021.1888987] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Affiliation(s)
- Liujiao Wang
- College of Chemistry, Beijing University of Chemical Technology, Beijing, P.R. China
| | - Rixin You
- College of Chemistry, Beijing University of Chemical Technology, Beijing, P.R. China
| | - Yuxuan Ling
- College of Chemistry, Beijing University of Chemical Technology, Beijing, P.R. China
| | - Yu Xie
- College of Chemistry, Beijing University of Chemical Technology, Beijing, P.R. China
| | - Cenyu Mei
- College of Chemistry, Beijing University of Chemical Technology, Beijing, P.R. China
| | - Ziming Li
- College of Chemistry, Beijing University of Chemical Technology, Beijing, P.R. China
| | - Fanghui Wang
- College of Chemistry, Beijing University of Chemical Technology, Beijing, P.R. China
| |
Collapse
|
7
|
|
8
|
Pagels MK, Adhikari S, Walgama RC, Singh A, Han J, Shin D, Bae C. One-Pot Synthesis of Proton Exchange Membranes from Anion Exchange Membrane Precursors. ACS Macro Lett 2020; 9:1489-1493. [PMID: 35653668 DOI: 10.1021/acsmacrolett.0c00550] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Proton exchange membranes (PEMs) play a critical role in many electrochemical devices that could solve the shortcomings of current energy storage and conversion systems. Hydrocarbon-based PEMs are an attractive alternative for replacing the state-of-the-art perfluorosulfonic acid PEMs; however, synthetic routes are generally limited to sulfonation of aromatic units (pre- or postpolymerization functionalization). Here we disclose a facile and scalable one-pot synthetic method of converting an alkyl halide functionality to a sulfonate in polymer systems. With this method, sulfonated hydrocarbon PEMs can be conveniently prepared from a precursor polymer of anion exchange membranes which have recently experienced significant advances. Polyphenylene type PEMs (BPSA and mTPSA in this report) were generated in one-pot SN2 reaction of bromoalkyl side chains of polymers followed by oxidation. These PEMs showed excellent proton conductivity with BPSA showing 250 mS/cm in water at 80 °C, nearly 1.5 times higher than that of Nafion 212. Furthermore, the separation of the sulfonic acid group from the rigid backbone with a flexible alkyl chain mitigates excessive water uptake and in-plane swelling ratio of the polymer, despite having a high ion exchange capacity of 2.6 mequiv/g. Oxidative stability was also shown to be superior for hydrocarbon-based PEMs with negligible changes in mass, NMR, and proton conductivity.
Collapse
Affiliation(s)
- Michael K Pagels
- Department of Chemistry & Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Santosh Adhikari
- Department of Chemistry & Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Ramali C Walgama
- Department of Chemistry & Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Asheesh Singh
- Department of Chemistry & Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Junyoung Han
- Department of Chemistry & Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Dongwon Shin
- Department of Chemistry & Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Chulsung Bae
- Department of Chemistry & Chemical Biology, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| |
Collapse
|
9
|
Li Z, Li C, Long C, Sang J, Tian L, Wang F, Wang Z, Zhu H. Elastic and durable multi‐cation‐crosslinked anion exchange membrane based on poly(styrene‐
b
‐(ethylene‐
co
‐butylene)‐
b
‐styrene). JOURNAL OF POLYMER SCIENCE 2020. [DOI: 10.1002/pol.20200290] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Ziming Li
- State Key Laboratory of Chemical Resource Engineering, College of ChemistryBeijing University of Chemical Technology Beijing China
| | - Conghui Li
- State Key Laboratory of Chemical Resource Engineering, College of ChemistryBeijing University of Chemical Technology Beijing China
| | - Chuan Long
- State Key Laboratory of Chemical Resource Engineering, College of ChemistryBeijing University of Chemical Technology Beijing China
| | - Jing Sang
- State Key Laboratory of Chemical Resource Engineering, College of ChemistryBeijing University of Chemical Technology Beijing China
| | - Lin Tian
- State Key Laboratory of Chemical Resource Engineering, College of ChemistryBeijing University of Chemical Technology Beijing China
| | - Fanghui Wang
- State Key Laboratory of Chemical Resource Engineering, College of ChemistryBeijing University of Chemical Technology Beijing China
| | - Zhihua Wang
- State Key Laboratory of Chemical Resource Engineering, College of ChemistryBeijing University of Chemical Technology Beijing China
| | - Hong Zhu
- State Key Laboratory of Chemical Resource Engineering, College of ChemistryBeijing University of Chemical Technology Beijing China
| |
Collapse
|