1
|
Mendoza ASG, Acosta MFM, Sánchez JAM, Vázquez LEC. Principles and challenges of whole cell microbial biosensors in the food industry. J Food Sci 2024; 89:5255-5269. [PMID: 39175184 DOI: 10.1111/1750-3841.17294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Revised: 07/05/2024] [Accepted: 07/23/2024] [Indexed: 08/24/2024]
Abstract
Whole cell microbial biosensors (WCMB) are mostly genetically modified microorganisms used to detect target molecules as indicators of biological and chemical contaminants as well as in the identification of compounds of interest in the food industry. The specificity and sensitivity of these biosensors are achieved through the design of genetic circuits that make use of genetic sequences such as promoters, terminators, genes encoding regulatory proteins or reporter proteins, among others. Despite the advances of WCMBs for their application, significant challenges are faced, such as cell stability, regulatory restrictions, and the need to optimize response times so that they can be a competitive detection tool in the market. This review explores the technological progress, potential and limitations of WCMBs in the food industry, starting by reviewing the operating principles of biosensors. The importance of selecting appropriate chassis cells and the integration of recognition elements and transducers to maximize their effectiveness in the detection of contaminants and compounds of interest in the food industry is highlighted.
Collapse
Affiliation(s)
- América Selene Gaona Mendoza
- Graduate Program in Biosciences, Life Science Division, University of Guanajuato Campus Irapuato-Salamanca, Irapuato, Guanajuato, México
- Food Department, Life Science Division, University of Guanajuato Campus Irapuato-Salamanca, Irapuato, Guanajuato, México
| | - María Fernanda Mendoza Acosta
- Graduate Program in Biosciences, Life Science Division, University of Guanajuato Campus Irapuato-Salamanca, Irapuato, Guanajuato, México
- Food Department, Life Science Division, University of Guanajuato Campus Irapuato-Salamanca, Irapuato, Guanajuato, México
| | - Julio Armando Massange Sánchez
- Plant Biotechnology Unit, Center for Research and Assistance in Technology and Design of the State of Jalisco A.C. (CIATEJ), Guadalajara, Mexico
| | - Luz Edith Casados Vázquez
- Graduate Program in Biosciences, Life Science Division, University of Guanajuato Campus Irapuato-Salamanca, Irapuato, Guanajuato, México
- Food Department, Life Science Division, University of Guanajuato Campus Irapuato-Salamanca, Irapuato, Guanajuato, México
- CONAHCyT-University of Guanajuato, Guanajuato, México
| |
Collapse
|
2
|
Allen ME, Kamilova E, Monck C, Ceroni F, Hu Y, Yetisen AK, Elani Y. Engineered Bacteria as Living Biosensors in Dermal Tattoos. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2309509. [PMID: 38884139 PMCID: PMC11321667 DOI: 10.1002/advs.202309509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 05/02/2024] [Indexed: 06/18/2024]
Abstract
Dermal tattoo biosensors are promising platforms for real-time monitoring of biomarkers, with skin used as a diagnostic interface. Traditional tattoo sensors have utilized small molecules as biosensing elements. However, the rise of synthetic biology has enabled the potential employment of engineered bacteria as living analytical tools. Exploiting engineered bacterial sensors will allow for potentially more sensitive detection across a broad biomarker range, with advanced processing and sense/response functionalities using genetic circuits. Here, the interfacing of bacterial biosensors as living analytics in tattoos is shown. Engineered bacteria are encapsulated into micron-scale hydrogel beads prepared through scalable microfluidics. These biosensors can sense both biochemical cues (model biomarkers) and biophysical cues (temperature changes, using RNA thermometers), with fluorescent readouts. By tattooing beads into skin models and confirming sensor activity post-tattooing, our study establishes a foundation for integrating bacteria as living biosensing entities in tattoos.
Collapse
Affiliation(s)
- Matthew E. Allen
- Department of ChemistryImperial College LondonMolecular Sciences Research HubLondonW12 0BZUK
- Institute of Chemical BiologyImperial College LondonMolecular Sciences Research HubLondonW12 0BZUK
- Department of Chemical EngineeringImperial College LondonSouth KensingtonLondonSW7 2AZUK
- fabriCELLImperial College London and King's College LondonLondonW12 0BZUK
| | - Elina Kamilova
- Department of Chemical EngineeringImperial College LondonSouth KensingtonLondonSW7 2AZUK
| | - Carolina Monck
- Department of Chemical EngineeringImperial College LondonSouth KensingtonLondonSW7 2AZUK
| | - Francesca Ceroni
- Department of Chemical EngineeringImperial College LondonSouth KensingtonLondonSW7 2AZUK
| | - Yubing Hu
- Department of Chemical EngineeringImperial College LondonSouth KensingtonLondonSW7 2AZUK
| | - Ali K. Yetisen
- Department of Chemical EngineeringImperial College LondonSouth KensingtonLondonSW7 2AZUK
| | - Yuval Elani
- Institute of Chemical BiologyImperial College LondonMolecular Sciences Research HubLondonW12 0BZUK
- Department of Chemical EngineeringImperial College LondonSouth KensingtonLondonSW7 2AZUK
- fabriCELLImperial College London and King's College LondonLondonW12 0BZUK
| |
Collapse
|
3
|
Belluati A, Harley I, Lieberwirth I, Bruns N. An Outer Membrane-Inspired Polymer Coating Protects and Endows Escherichia coli with Novel Functionalities. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2303384. [PMID: 37452438 DOI: 10.1002/smll.202303384] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/06/2023] [Indexed: 07/18/2023]
Abstract
A bio-inspired membrane made of Pluronic L-121 is produced around Escherichia coli thanks to the simple co-extrusion of bacteria and polymer vesicles. The block copolymer-coated bacteria can withstand various harsh shocks, for example, temperature, pressure, osmolarity, and chemical agents. The polymer membrane also makes the bacteria resistant to enzymatic digestion and enables them to degrade toxic compounds, improving their performance as whole-cell biocatalysts. Moreover, the polymer membrane acts as an anchor layer for the surface modification of the bacteria. Being decorated with α-amylase or lysozyme, the cells are endowed with the ability to digest starch or self-predatory bacteria are created. Thus, without any genetic engineering, the phenotype of encapsulated bacteria is changed as they become sturdier and gain novel metabolic functionalities.
Collapse
Affiliation(s)
- Andrea Belluati
- Department of Chemistry and Centre for Synthetic Biology, Technical University of Darmstadt, Peter-Grünberg-Straße 4, 64287, Darmstadt, Germany
- Department of Pure and Applied Chemistry, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL, UK
| | - Iain Harley
- Department of Physical Chemistry of Polymers, Max Planck Institute for Polymer Research, Ackermannweg 10, 55128, Mainz, Germany
| | - Ingo Lieberwirth
- Department of Physical Chemistry of Polymers, Max Planck Institute for Polymer Research, Ackermannweg 10, 55128, Mainz, Germany
| | - Nico Bruns
- Department of Chemistry and Centre for Synthetic Biology, Technical University of Darmstadt, Peter-Grünberg-Straße 4, 64287, Darmstadt, Germany
- Department of Pure and Applied Chemistry, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL, UK
| |
Collapse
|
4
|
Roshid MHO, Moraskie M, O’Connor G, Dikici E, Zingg JM, Deo S, Bachas LG, Daunert S. A Portable, Encapsulated Microbial Whole-Cell Biosensing System for the Detection of Bioavailable Copper (II) in Soil. Microchem J 2023; 193:109088. [PMID: 37982106 PMCID: PMC10655828 DOI: 10.1016/j.microc.2023.109088] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2023]
Abstract
A portable, field deployable whole-cell biosensor was developed that can withstand the complex matrices of soil and requires minimal to no sample preparation to monitor bioavailable concentrations of the essential micronutrient copper (II). Conventional measurement of micronutrients is often complex, laboratory-based, and not suitable for monitoring their bioavailable concentration. To address this need, we developed a fluorescence based microbial whole-cell biosensing (MWCB) system encoding for a Cu2+-responsive protein capable of generating a signal upon binding to Cu2+. The sensing-reporting protein was designed by performing circular permutation on the green fluorescent protein (GFP) followed by insertion of a Cu2+ binding motif into the structure of GFP. The design included insertion of several binding motifs and creating plasmids that encoded the corresponding sensing proteins. The signal generated by the sensing-reporting protein is directly proportional to the concentration of Cu2+ in the sample. Evaluation of the resulting biosensing systems carrying these plasmids was performed prior to selection of the optimal fluorescence emitting Cu2+-binding protein. The resulting optimized biosensing system was encapsulated in polyacrylate-alginate beads and embedded in soil for detection of the analyte. Once exposed to the soil, the beads were interrogated to measure the fluorescence signal emitted by the sensing-reporting protein using a portable imaging device. The biosensor was optimized for detection of Cu2+ in terms of selectivity, sensitivity, matrix effects, detection limits, and reproducibility in both liquid and soil matrices. The limit of detection (LoD) of the optimized encapsulated biosensor was calculated as 0.27 mg/L and 1.26 mg/kg of Cu2+ for Cu2+ in solution and soil, respectively. Validation of the portable imaging tools as a potential biosensing device in the field was performed.
Collapse
Affiliation(s)
- Md Harun Or Roshid
- Department of Chemistry, University of Miami, Miami, FL 33146
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136
- The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL 33136
| | - Michael Moraskie
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136
- The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL 33136
| | - Gregory O’Connor
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136
- The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL 33136
| | - Emre Dikici
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136
- The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL 33136
| | - Jean-Marc Zingg
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136
- The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL 33136
| | - Sapna Deo
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136
- The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL 33136
| | - Leonidas G. Bachas
- Department of Chemistry, University of Miami, Miami, FL 33146
- The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL 33136
| | - Sylvia Daunert
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136
- The Dr. John T. Macdonald Foundation Biomedical Nanotechnology Institute - BioNIUM, University of Miami, Miami, FL 33136
- The Miami Clinical and Translational Science Institute, University of Miami, Miami, FL 33146
- Sylvester Comprehensive Cancer Center, University of Miami, Miami, FL 33146
| |
Collapse
|
5
|
Aghlara-Fotovat S, Musteata E, Doerfert MD, Baruch M, Levitan M, Tabor JJ, Veiseh O. Hydrogel-encapsulation to enhance bacterial diagnosis of colon inflammation. Biomaterials 2023; 301:122246. [PMID: 37481834 PMCID: PMC10792543 DOI: 10.1016/j.biomaterials.2023.122246] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 06/13/2023] [Accepted: 07/12/2023] [Indexed: 07/25/2023]
Abstract
Bacteria can be genetically programmed to sense and report the presence of disease biomarkers in the gastrointestinal (GI) tract. However, diagnostic bacteria are typically delivered via oral administration of liquid cultures, resulting in poor survival and high dispersal in vivo. These limitations confound recovery and analysis of engineered bacteria from GI or stool samples. Here, we demonstrate that encapsulating bacteria inside of alginate core-shell particles enables robust survival, containment, and diagnostic function in vivo. We demonstrate these benefits by encapsulating a strain engineered to report the presence of the biomarker thiosulfate via fluorescent protein expression in order to diagnose dextran sodium sulfate-induced colitis in rats. Hydrogel-encapsulated bacteria engineered to sense and respond to physiological stimuli should enable minimally invasive monitoring of a wide range of diseases and have applications as next-generation smart therapeutics.
Collapse
Affiliation(s)
| | - Elena Musteata
- Systems Synthetic and Physical Biology, Rice University, Houston, TX, USA
| | | | - Moshe Baruch
- Department of Bioengineering, Rice University, Houston, TX, USA
| | - Maya Levitan
- Department of Bioengineering, Rice University, Houston, TX, USA
| | - Jeffrey J Tabor
- Department of Bioengineering, Rice University, Houston, TX, USA; Systems Synthetic and Physical Biology, Rice University, Houston, TX, USA; Department of Biosciences, Rice University, Houston, TX, USA.
| | - Omid Veiseh
- Department of Bioengineering, Rice University, Houston, TX, USA.
| |
Collapse
|
6
|
Allen ME, Hindley JW, O’Toole N, Cooke HS, Contini C, Law RV, Ces O, Elani Y. Biomimetic behaviors in hydrogel artificial cells through embedded organelles. Proc Natl Acad Sci U S A 2023; 120:e2307772120. [PMID: 37603747 PMCID: PMC10466294 DOI: 10.1073/pnas.2307772120] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 07/13/2023] [Indexed: 08/23/2023] Open
Abstract
Artificial cells are biomimetic structures formed from molecular building blocks that replicate biological processes, behaviors, and architectures. Of these building blocks, hydrogels have emerged as ideal, yet underutilized candidates to provide a gel-like chassis in which to incorporate both biological and nonbiological componentry which enables the replication of cellular functionality. Here, we demonstrate a microfluidic strategy to assemble biocompatible cell-sized hydrogel-based artificial cells with a variety of different embedded functional subcompartments, which act as engineered synthetic organelles. The organelles enable the recreation of increasingly biomimetic behaviors, including stimulus-induced motility, content release through activation of membrane-associated proteins, and enzymatic communication with surrounding bioinspired compartments. In this way, we showcase a foundational strategy for the bottom-up construction of hydrogel-based artificial cell microsystems which replicate fundamental cellular behaviors, paving the way for the construction of next-generation biotechnological devices.
Collapse
Affiliation(s)
- Matthew E. Allen
- Department of Chemistry, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
- Department of Chemical Engineering, Imperial College London, South Kensington, LondonSW7 2AZ, UK
- FabriCELL, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
| | - James W. Hindley
- Department of Chemistry, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
- FabriCELL, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
| | - Nina O’Toole
- Department of Chemical Engineering, Imperial College London, South Kensington, LondonSW7 2AZ, UK
- FabriCELL, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
| | - Hannah S. Cooke
- Department of Chemistry, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
- Department of Chemical Engineering, Imperial College London, South Kensington, LondonSW7 2AZ, UK
- FabriCELL, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
| | - Claudia Contini
- Department of Chemical Engineering, Imperial College London, South Kensington, LondonSW7 2AZ, UK
- FabriCELL, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
| | - Robert V. Law
- Department of Chemistry, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
- FabriCELL, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
| | - Oscar Ces
- Department of Chemistry, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
- FabriCELL, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
| | - Yuval Elani
- Department of Chemical Engineering, Imperial College London, South Kensington, LondonSW7 2AZ, UK
- FabriCELL, Imperial College London, Molecular Sciences Research Hub, LondonW12 0BZ, UK
| |
Collapse
|
7
|
Zúñiga A, Muñoz-Guamuro G, Boivineau L, Mayonove P, Conejero I, Pageaux GP, Altwegg R, Bonnet J. A rapid and standardized workflow for functional assessment of bacterial biosensors in fecal samples. Front Bioeng Biotechnol 2022; 10:859600. [PMID: 36072290 PMCID: PMC9444133 DOI: 10.3389/fbioe.2022.859600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 07/05/2022] [Indexed: 11/17/2022] Open
Abstract
Gut metabolites are pivotal mediators of host-microbiome interactions and provide an important window on human physiology and disease. However, current methods to monitor gut metabolites rely on heavy and expensive technologies such as liquid chromatography-mass spectrometry (LC-MS). In that context, robust, fast, field-deployable, and cost-effective strategies for monitoring fecal metabolites would support large-scale functional studies and routine monitoring of metabolites biomarkers associated with pathological conditions. Living cells are an attractive option to engineer biosensors due to their ability to detect and process many environmental signals and their self-replicating nature. Here we optimized a workflow for feces processing that supports metabolite detection using bacterial biosensors. We show that simple centrifugation and filtration steps remove host microbes and support reproducible preparation of a physiological-derived media retaining important characteristics of human feces, such as matrix effects and endogenous metabolites. We measure the performance of bacterial biosensors for benzoate, lactate, anhydrotetracycline, and bile acids, and find that they are highly sensitive to fecal matrices. However, encapsulating the bacteria in hydrogel helps reduce this inhibitory effect. Sensitivity to matrix effects is biosensor-dependent but also varies between individuals, highlighting the need for case-by-case optimization for biosensors’ operation in feces. Finally, by detecting endogenous bile acids, we demonstrate that bacterial biosensors could be used for future metabolite monitoring in feces. This work lays the foundation for the optimization and use of bacterial biosensors for fecal metabolites monitoring. In the future, our method could also allow rapid pre-prototyping of engineered bacteria designed to operate in the gut, with applications to in situ diagnostics and therapeutics.
Collapse
Affiliation(s)
- Ana Zúñiga
- Centre de Biologie Structurale (CBS), INSERM U1054, CNRS UMR5048, University of Montpellier, Montpellier, France
- *Correspondence: Ana Zúñiga, ; Jerome Bonnet,
| | - Geisler Muñoz-Guamuro
- Centre de Biologie Structurale (CBS), INSERM U1054, CNRS UMR5048, University of Montpellier, Montpellier, France
| | - Lucile Boivineau
- Hepatogastroenterology and Bacteriology Service at CHU Montpellier, University of Montpellier, Montpellier, France
| | - Pauline Mayonove
- Centre de Biologie Structurale (CBS), INSERM U1054, CNRS UMR5048, University of Montpellier, Montpellier, France
| | - Ismael Conejero
- Department of Psychiatry, CHU Nimes, University of Montpellier, Montpellier, France
| | - Georges-Philippe Pageaux
- Hepatogastroenterology and Bacteriology Service at CHU Montpellier, University of Montpellier, Montpellier, France
| | - Romain Altwegg
- Hepatogastroenterology and Bacteriology Service at CHU Montpellier, University of Montpellier, Montpellier, France
| | - Jerome Bonnet
- Centre de Biologie Structurale (CBS), INSERM U1054, CNRS UMR5048, University of Montpellier, Montpellier, France
- *Correspondence: Ana Zúñiga, ; Jerome Bonnet,
| |
Collapse
|
8
|
Liu X, Inda ME, Lai Y, Lu TK, Zhao X. Engineered Living Hydrogels. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2201326. [PMID: 35243704 PMCID: PMC9250645 DOI: 10.1002/adma.202201326] [Citation(s) in RCA: 85] [Impact Index Per Article: 28.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 03/01/2022] [Indexed: 05/31/2023]
Abstract
Living biological systems, ranging from single cells to whole organisms, can sense, process information, and actuate in response to changing environmental conditions. Inspired by living biological systems, engineered living cells and nonliving matrices are brought together, which gives rise to the technology of engineered living materials. By designing the functionalities of living cells and the structures of nonliving matrices, engineered living materials can be created to detect variability in the surrounding environment and to adjust their functions accordingly, thereby enabling applications in health monitoring, disease treatment, and environmental remediation. Hydrogels, a class of soft, wet, and biocompatible materials, have been widely used as matrices for engineered living cells, leading to the nascent field of engineered living hydrogels. Here, the interactions between hydrogel matrices and engineered living cells are described, focusing on how hydrogels influence cell behaviors and how cells affect hydrogel properties. The interactions between engineered living hydrogels and their environments, and how these interactions enable versatile applications, are also discussed. Finally, current challenges facing the field of engineered living hydrogels for their applications in clinical and environmental settings are highlighted.
Collapse
Affiliation(s)
- Xinyue Liu
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Maria Eugenia Inda
- Synthetic Biology Group, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Yong Lai
- Synthetic Biology Group, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Timothy K Lu
- Synthetic Biology Group, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Xuanhe Zhao
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| |
Collapse
|