1
|
Rahman MM, Islam A, Mamun MA, Afroz MS, Nabi MM, Sakamoto T, Sato T, Kahyo T, Takahashi Y, Okino A, Setou M. Low-Temperature Plasma Pretreatment Enhanced Cholesterol Detection in Brain by Desorption Electrospray Ionization-Mass Spectrometry Imaging. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:1227-1236. [PMID: 38778699 DOI: 10.1021/jasms.4c00045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2024]
Abstract
Cholesterol is a primary lipid molecule in the brain that contains one-fourth of the total body cholesterol. Abnormal cholesterol homeostasis is associated with neurodegenerative disorders. Mass spectrometry imaging (MSI) technique is a powerful tool for studying lipidomics and metabolomics. Among the MSI techniques, desorption electrospray ionization-MSI (DESI-MSI) has been used advantageously to study brain lipidomics due to its soft and ambient ionization nature. However, brain cholesterol is poorly ionized. To this end, we have developed a new method for detecting brain cholesterol by DESI-MSI using low-temperature plasma (LTP) pretreatment as an ionization enhancement. In this method, the brain sections were treated with LTP for 1 and 2 min prior to DESI-MSI analyses. Interestingly, the MS signal intensity of cholesterol (at m/z 369.35 [M + H - H2O]+) was more than 2-fold higher in the 1 min LTP-treated brain section compared to the untreated section. In addition, we detected cholesterol, more specifically excluding isomers by targeted-DESI-MSI in multiple reaction monitoring (MRM) mode and similar results were observed: the signal intensity of each cholesterol transition (m/z 369.4 → 95.1, 109.1, 135.1, 147.1, and 161.1) was increased by more than 2-fold due to 1 min LTP treatment. Cholesterol showed characteristic distributions in the fiber tract region, including the corpus callosum and anterior commissure, anterior part of the brain where LTP markedly (p < 0.001) enhanced the cholesterol intensity. In addition, the distributions of some unknown analytes were exclusively detected in the LTP-treated section. Our study revealed LTP pretreatment as a potential strategy to ionize molecules that show poor ionization efficiency in the MSI technique.
Collapse
Affiliation(s)
- Md Muedur Rahman
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
- Preppers Co., Ltd., Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
| | - Ariful Islam
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
- Preppers Co., Ltd., Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
- Department of Biochemistry and Microbiology, School of Health and Life Sciences, North South University, Bashundhara, Dhaka 1229, Bangladesh
| | - Md Al Mamun
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
- Preppers Co., Ltd., Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
| | - Mst Sayela Afroz
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
| | - Md Mahamodun Nabi
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
| | - Takumi Sakamoto
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
- Preppers Co., Ltd., Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
| | - Tomohito Sato
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
| | - Tomoaki Kahyo
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
- Quantum Imaging Laboratory, International Mass Imaging and Spatial Omics Center, Institute of Photonics Medicine, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
| | - Yutaka Takahashi
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
- Preppers Co., Ltd., Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
| | - Akitoshi Okino
- Laboratory for Future Interdisciplinary Research of Science and Technology, Institute of Innovative Research, Tokyo Institute of Technology, J2-32, 4259 Nagatsuta, Midori-ku, Yokohama 226-8502, Japan
| | - Mitsutoshi Setou
- Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
- International Mass Imaging and Spatial Omics Center, Institute of Photonics Medicine, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, Shizuoka 431-3192, Japan
| |
Collapse
|
2
|
Bouza M, Ahlmann N, García-Reyes JF, Franzke J. Solvent-Assisted Laser Desorption Flexible Microtube Plasma Mass Spectrometry for Direct Analysis of Dried Samples on Paper. Anal Chem 2023; 95:18370-18378. [PMID: 37902451 PMCID: PMC10733904 DOI: 10.1021/acs.analchem.3c03009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 09/11/2023] [Accepted: 10/20/2023] [Indexed: 10/31/2023]
Abstract
The present study investigated the potential for solvent-assisted laser desorption coupled with flexible microtube plasma ionization mass spectrometry (SALD-FμTP-MS) as a rapid analytical technique for direct analysis of surface-deposited samples. Paper was used as the demonstrative substrate, and an infrared hand-held laser was employed for sample desorption, aiming to explore cost-effective sampling and analysis methods. SALD-FμTP-MS offers several advantages, particularly for biofluid analysis, including affordability, the ability to analyze low sample volumes (<10 μL), expanded chemical coverage, sample and substrate stability, and in situ analysis and high throughput potential. The optimization process involved exploring the use of viscous solvents with high boiling points as liquid matrices. This approach aimed to enhance desorption and ionization efficiencies. Ethylene glycol (EG) was identified as a suitable solvent, which not only improved sensitivity but also ensured substrate stability during analysis. Furthermore, the addition of cosolvents such as acetonitrile/water (1:1) and ethyl acetate further enhanced sensitivity and reproducibility for a standard solution containing amphetamine, imazalil, and cholesterol. Optimized conditions for reproducible and sensitive analysis were determined as 1000 ms of laser exposure time using a 1 μL solvent mixture of 60% EG and 40% acetonitrile (ACN)/water (1:1). A mixture of 60% EG and 40% ACN/water (1:1) resulted in signal enhancements and relative standard deviations of 12, 20, and 13% for the evaluated standards, respectively. The applicability of SALD-FμTP-MS was further evaluated by successfully analyzing food, water, and biological samples, highlighting the potential of SALD-FμTP-MS analysis, particularly for thermolabile and polarity diverse compounds.
Collapse
Affiliation(s)
- Marcos Bouza
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071 Jaén, Spain
| | - Norman Ahlmann
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Juan F. García-Reyes
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071 Jaén, Spain
| | - Joachim Franzke
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| |
Collapse
|
3
|
Heide M, Engelhard C. Effect of Sample Plates and Sample Matrix on the Quantification Capabilities of Surface-Assisted Flowing Atmospheric-Pressure Afterglow Mass Spectrometry (SA-FAPA-MS). APPLIED SPECTROSCOPY 2023; 77:928-939. [PMID: 37151022 DOI: 10.1177/00037028231168617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Ambient desorption/ionization mass spectrometry (ADI-MS) has been broadly applied to accomplish direct analysis without sample preparation or separation. However, quantification capabilities and analytical performance are sometimes limited. Here, we report signal enhancement effects and improved quantification capabilities in plasma-based ADI-MS, when a flowing atmospheric-pressure afterglow (FAPA) source is used to probe analytes on tailored thin-layer chromatography (TLC) plates. It was found that quantitative results could be achieved when the TLC plate merely served as a sampling plate without a preceding separation step. Specifically, the dynamic response of caffeine, nicotine, acetaminophen, and progesterone was investigated with FAPA-MS on a variety of different TLC surfaces (normal-phase silica, reversed-phase-modified silica, cyano [CN]-modified silica, and dimethyl [RP2]-modified silica). All analytes were studied as single-analyte standards and in a multianalyte mixture to evaluate the effect of sample plates and sample matrix on analytical performance and competitive ionization processes. Overall, dimethyl (RP2)- and CN-modified silica resulted in superior performance compared to other TLC materials. After careful optimization and without the use of internal standards, linear ranges of five orders of magnitude were accessible for caffeine and nicotine. Limits of detection down to femtomole amounts of analyte were achieved. Quantitation limits using RP2-TLC and FAPA-MS were 0.062, 0.062l, 0.31, and 14 pmol for caffeine, nicotine, progesterone, and acetaminophen, respectively. Interestingly, the presence of nicotine at relatively high amounts reduced the signal of the other analytes, an observation that was found to correlate with the differences in the enthalpy of vaporization (ΔHvap) and proton affinity. To prove the quantitative capabilities, nicotine quantification in a real matrix-heavy e-liquid sample was demonstrated using an isotopically labeled standard. The use of TLC-based surfaces with FAPA-MS can aid in the direct and quantitative mass spectrometric investigation of complex mixtures.
Collapse
Affiliation(s)
- Maximilian Heide
- Department of Chemistry and Biology, University of Siegen, Siegen, Germany
| | - Carsten Engelhard
- Department of Chemistry and Biology, University of Siegen, Siegen, Germany
- Research Center of Micro- and Nanochemistry and (Bio)Technology, University of Siegen, Siegen, Germany
| |
Collapse
|
4
|
Wilson ID, Poole CF. Planar chromatography - Current practice and future prospects. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1214:123553. [PMID: 36495686 DOI: 10.1016/j.jchromb.2022.123553] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 11/01/2022] [Accepted: 11/24/2022] [Indexed: 11/29/2022]
Abstract
Planar chromatography, in the form of thin-layer or high-performance thin-layer chromatography (TLC, HPTLC), continues to provide a robust and widely used separation technique. It is unrivaled as a simple and rapid qualitative method for mixture analysis, or for finding bioactive components in mixtures. The format of TLC/HPTLC also provides a unique method for preserving the separation, enabling further investigation of components of interest (including quantification/structure determination) separated in both time and space from the original analysis. The current practice of planar chromatography and areas of development of the technology are reviewed and promising future directions in the use of TLC/HPTLC are outlined.
Collapse
Affiliation(s)
- Ian D Wilson
- Division of Systems Medicine, Department of Metabolism, Digestion and Reproduction, Imperial College, Burlington Danes Building, Du Cane Road, London W12 0NN, UK.
| | - Colin F Poole
- Department of Chemistry, Wayne State University, Detroit, MI 48202, USA.
| |
Collapse
|
5
|
Yue H, He F, Zhao Z, Duan Y. Plasma-based ambient mass spectrometry: Recent progress and applications. MASS SPECTROMETRY REVIEWS 2023; 42:95-130. [PMID: 34128567 DOI: 10.1002/mas.21712] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 05/28/2020] [Accepted: 06/02/2020] [Indexed: 06/12/2023]
Abstract
Ambient mass spectrometry (AMS) has grown as a group of advanced analytical techniques that allow for the direct sampling and ionization of the analytes in different statuses from their native environment without or with minimum sample pretreatments. As a significant category of AMS, plasma-based AMS has gained a lot of attention due to its features that allow rapid, real-time, high-throughput, in vivo, and in situ analysis in various fields, including bioanalysis, pharmaceuticals, forensics, food safety, and mass spectrometry imaging. Tens of new methods have been developed since the introduction of the first plasma-based AMS technique direct analysis in real-time. This review first provides a comprehensive overview of the established plasma-based AMS techniques from their ion source configurations, mechanisms, and developments. Then, the progress of the representative applications in various scientific fields in the past 4 years (January 2017 to January 2021) has been summarized. Finally, we discuss the current challenges and propose the future directions of plasma-based AMS from our perspective.
Collapse
Affiliation(s)
- Hanlu Yue
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Feiyao He
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Zhongjun Zhao
- School of Chemical Engineering, Sichuan University, Chengdu, China
| | - Yixiang Duan
- College of Life Sciences, Sichuan University, Chengdu, China
- School of Manufacturing Science and Engineering, Sichuan University, Chengdu, China
| |
Collapse
|
6
|
Gong X, Shi S, Zhang D, Gamez G. Quantitative Analysis of Exhaled Breath Collected on Filter Substrates via Low-Temperature Plasma Desorption/Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:1518-1529. [PMID: 35792104 DOI: 10.1021/jasms.2c00109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Breath analysis has attracted increasing attention in recent years due to its great potential for disease diagnostics at early stages and for clinical drug monitoring. There are several recent examples of successful development of real-time, in vivo quantitative analysis of exhaled breath metabolites via mass spectrometry. On the other hand, current mass spectrometer accessibility limitations restrict point-of-care applications. Here now, an offline method is developed for quantitative analysis of exhaled breath collected on inexpensive filter substrates for direct desorption and ionization by using low-temperature plasma-mass spectrometry (LTP-MS). In particular, different operating conditions of the ionization source were systematically studied to optimize desorption/ionization by using glycerol, a low volatility compound. Applications with respect to propofol, γ-valprolactone, and nicotine analysis in exhaled breath are demonstrated in this study. The effects of several filter substrate properties, including filter material and pore size, on the analyte signal were characterized. Cellulose filter papers performed best with the present analytes. In addition, filters with smaller pores enabled a more efficient sample collection. Furthermore, sample-collection flow rate was determined to have a very significant effect, with slower flow rates yielding the best results. It was also found that filters loaded with sample can be successfully stored in glass vials with no observable sample loss even after 3 days. Limits of detection under optimized conditions are shown to be competitive or significantly better compared with relevant techniques and with additional benefits of cost-efficiency and sample storage capabilities.
Collapse
Affiliation(s)
- Xiaoxia Gong
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Songyue Shi
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Dong Zhang
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Gerardo Gamez
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| |
Collapse
|
7
|
Quantitative detection of caffeine in beverages using flowing atmospheric-pressure afterglow (FAPA) ionization high-resolution mass spectrometry imaging and performance evaluation of different thin-layer chromatography plates as sample substrates. Anal Bioanal Chem 2022; 414:4481-4495. [PMID: 35441859 PMCID: PMC9142459 DOI: 10.1007/s00216-022-04045-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 03/18/2022] [Accepted: 03/24/2022] [Indexed: 11/01/2022]
Abstract
Ambient desorption/ionization mass spectrometry (ADI-MS) is widely used as a rapid screening tool of samples in their native state without sample preparation. While analysis times are much less than 1 min per sample, one challenge of ADI-MS is the possibility to perform quantitative analysis of analytes in complex matrices. Typically, the goal is to probe a variety of different analytes in a complex matrix from a solid, liquid, or otherwise uncharacterized surface in the open air in front of the MS inlet. In this study, it is demonstrated that a carefully selected surface for analyte spot sampling and co-deposited isotopically labeled standards both significantly improve the capabilities of flowing atmospheric-pressure afterglow (FAPA) high-resolution (HR) MS for direct quantitative analysis. Specifically, a systematic study of different surfaces (glass, steel mesh, high-performance thin-layer chromatography (HPTLC) stationary phases including silica, reversed-phase (RP)-modified silica, and cyano (CN)-modified silica) and their suitability for spot sampling with FAPA-MS was performed. A set of different caffeine-containing standards and beverages (Red Bull, Coca-Cola, coffee, and black tea) was deposited on the surfaces and direct FAPA-HR-MS analysis of caffeine was performed using internal calibration with co-deposited 13C3-caffeine. For TLC surfaces, it was demonstrated that quantitative results could be achieved with the matrix and concomitants present and that a preceding chromatographic separation was not mandatory for this application. In addition, the use of a CN-HPTLC surface resulted in a significantly more intense caffeine signal in the beverage samples compared to the other surfaces studied, with the highest increase compared to the silica (200-fold higher) and the lowest increase compared to the steel mesh (30-fold higher). The utilization of TLC-based surfaces as sample carriers is considered an attractive tool in the ADI-MS toolbox for fast and efficient mass spectrometric investigations of complex samples without time-consuming sample preparation.
Collapse
|
8
|
Claude E, Lafont R, Plumb RS, Wilson ID. High Performance Reversed-Phase Thin-Layer Chromatography-Desorption Electrospray Ionisation - Time of Flight High Resolution Mass Spectrometric Detection and Imaging (HPTLC/DESI/ToFMS) of Phytoecdysteroids. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1200:123265. [DOI: 10.1016/j.jchromb.2022.123265] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 04/05/2022] [Accepted: 04/24/2022] [Indexed: 02/04/2023]
|
9
|
Zhang D, Zeldes D, Gamez G. Three-Dimensional Mass Spectral Imaging of Polymers Via Laser-Assisted Micro-Pyrolysis Program with Flowing Atmospheric-Pressure Afterglow Ambient Mass Spectrometry. Anal Chem 2022; 94:3335-3342. [PMID: 35138081 DOI: 10.1021/acs.analchem.1c05413] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Herein, a novel diode laser-assisted micro-pyrolysis program (LAMP) technique is demonstrated and coupled with flowing atmospheric-pressure afterglow ambient mass spectrometry for instantaneously profiling polymers and polymer additives. Laser power modulation allows thermal separation of additives and different pyrolysis products, as shown through positive- and negative-mode high-resolution mass spectra and Kendrick mass defect plots of homopolymers, copolymers, polymer blends, and complex polymer samples. LAMP allows much faster temperature control through real-time duty cycle changes and gives significantly better spatial confinement compared to typical resistive heating pyrolysis approaches. Finally, MS imaging, with lateral and depth resolution, is demonstrated for a complex polymer pressure-sensitive adhesive tape sample.
Collapse
Affiliation(s)
- Dong Zhang
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - David Zeldes
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Gerardo Gamez
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| |
Collapse
|
10
|
Nabgan W, Jalil AA, Nabgan B, Ikram M, Ali MW, Lakshminarayana P. A state of the art overview of carbon-based composites applications for detecting and eliminating pharmaceuticals containing wastewater. CHEMOSPHERE 2022; 288:132535. [PMID: 34648794 DOI: 10.1016/j.chemosphere.2021.132535] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 09/16/2021] [Accepted: 10/08/2021] [Indexed: 06/13/2023]
Abstract
The growing prevalence of new toxins in the environment continues to cause widespread concerns. Pharmaceuticals, organic pollutants, heavy metal ions, endocrine-disrupting substances, microorganisms, and others are examples of persistent organic chemicals whose effects are unknown because they have recently entered the environment and are displaying up in wastewater treatment facilities. Pharmaceutical pollutants in discharged wastewater have become a danger to animals, marine species, humans, and the environment. Although their presence in drinking water has generated significant concerns, little is known about their destiny and environmental effects. As a result, there is a rising need for selective, sensitive, quick, easy-to-handle, and low-cost early monitoring detection systems. This study aims to deliver an overview of a low-cost carbon-based composite to detect and remove pharmaceutical components from wastewater using the literature reviews and bibliometric analysis technique from 1970 to 2021 based on the web of science (WoS) database. Various pollutants in water and soil were reviewed, and different methods were introduced to detect pharmaceutical pollutants. The advantages and drawbacks of varying carbon-based materials for sensing and removing pharmaceutical wastes were also introduced. Finally, the available techniques for wastewater treatment, challenges and future perspectives on the recent progress were highlighted. The suggestions in this article will facilitate the development of novel on-site methods for removing emerging pollutants from pharmaceutical effluents and commercial enterprises.
Collapse
Affiliation(s)
- Walid Nabgan
- School of Chemical and Energy Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Skudai, Johor, Malaysia; Centre of Hydrogen Energy, Institute of Future Energy, Universiti Teknologi Malaysia, 81310, Skudai, Johor, Malaysia.
| | - Aishah Abdul Jalil
- School of Chemical and Energy Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Skudai, Johor, Malaysia; Centre of Hydrogen Energy, Institute of Future Energy, Universiti Teknologi Malaysia, 81310, Skudai, Johor, Malaysia.
| | - Bahador Nabgan
- School of Chemical and Energy Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Skudai, Johor, Malaysia
| | - Muhammad Ikram
- Solar Cell Applications Research Lab, Department of Physics, Government College University Lahore, 54000, Punjab, Pakistan.
| | - Mohamad Wijayanuddin Ali
- School of Chemical and Energy Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Skudai, Johor, Malaysia; Centre of Hydrogen Energy, Institute of Future Energy, Universiti Teknologi Malaysia, 81310, Skudai, Johor, Malaysia
| | | |
Collapse
|
11
|
Borisov R, Kanateva A, Zhilyaev D. Recent Advances in Combinations of TLC With MALDI and Other Desorption/Ionization Mass-Spectrometry Techniques. Front Chem 2022; 9:771801. [PMID: 34976947 PMCID: PMC8719418 DOI: 10.3389/fchem.2021.771801] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 11/17/2021] [Indexed: 01/09/2023] Open
Abstract
The combination of planar chromatography with desorption/ionization mass-spectrometry (MS) techniques provides chemists with unique tools for fast and simple separation of mixtures followed by the detection of analytes by the most powerful analytical method. Since its introduction in the early 1990s, thin-layer chromatography (TLC)/matrix-assisted mass spectrometry (MALDI) has been used for the analysis of a wide range of analytes, including natural and synthetic organic compounds. Nowadays, new desorption/ionization approaches have been developed and applied in conjunction with planar chromatography competing with MALDI. This review covers recent developments in the combination of TLC with various desorption/ionization MS methods which were made in recent several years.
Collapse
Affiliation(s)
- Roman Borisov
- A. V. Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, Moscow, Russia.,Peoples Friendship University of Russia (RUDN University), Moscow, Russia
| | - Anastasiia Kanateva
- A. V. Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, Moscow, Russia
| | - Dmitry Zhilyaev
- A. V. Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, Moscow, Russia.,Peoples Friendship University of Russia (RUDN University), Moscow, Russia
| |
Collapse
|
12
|
Chen Y, Li L, Xu R, Li F, Gu L, Liu H, Wang Z, Yang L. Characterization of natural herbal medicines by thin-layer chromatography combined with laser ablation-assisted direct analysis in real-time mass spectrometry. J Chromatogr A 2021; 1654:462461. [PMID: 34438305 DOI: 10.1016/j.chroma.2021.462461] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Revised: 08/05/2021] [Accepted: 08/05/2021] [Indexed: 01/16/2023]
Abstract
The characterization and quality control of natural herbal medicines, such as traditional Chinese medicines (TCMs), is of great significance to ensure their potential efficacy and avoid severe side effects. Thin-layer chromatography (TLC) is a simple and classic approach for examining quality marker of natural products. Nevertheless, it is more difficult to further characterize the compounds adsorbed on the TLC plate. Herein, we reported a simple setup of laser ablation-assisted direct analysis in real-time mass spectrometry (LA-DART-MS), in which the coupling of mass spectrometry information to provide a predominant dimension in the identification of unknown chemical compositions separated on standard TLC plates, and it was applied for rapid characterization of various kinds of natural herbal medicines. The results showed that the introduction of low-cost small laser pointer had significantly improved the desorption process. The system was successfully applied in the analysis of alkaloids, flavonoids, anthraquinones, volatile oils, glycosides, organic acids, and eight different TCMs including Sophorae Flavescentis Radix, Angelicae Sinensis Radix, Acori Tatarinowii Rhizoma, Phellodendri Chinensis Cortex, Picrasmae Ramulus et Folium, Gynura Japonica, Rhei Radix et Rhizoma and Dendrobii Caulis. The obtained limits of detection (LODs) of this method for various types of reference substances were in the range of 4.6-162.2 ng/band on TLC plates. Furthermore, the quality control and identification of different species of Dendrobii Caulis herb was achieved. This study combines the advantages of TLC and ambient mass spectrometry to provide a good choice for the screening and identification of active ingredients and the quality evaluation of botanical samples.
Collapse
Affiliation(s)
- Yilin Chen
- The MOE Key Laboratory of Standardization of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicines, and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China; Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Linnan Li
- The MOE Key Laboratory of Standardization of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicines, and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
| | - Rui Xu
- The MOE Key Laboratory of Standardization of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicines, and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Fan Li
- The MOE Key Laboratory of Standardization of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicines, and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Lihua Gu
- The MOE Key Laboratory of Standardization of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicines, and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Huwei Liu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
| | - Zhengtao Wang
- The MOE Key Laboratory of Standardization of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicines, and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Li Yang
- The MOE Key Laboratory of Standardization of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicines, and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China; Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
| |
Collapse
|
13
|
Oliva M, Zhang D, Prada-Tiedemann P, Gamez G. Laser assisted sampling vs direct desorption flowing atmospheric pressure afterglow mass spectrometry of complex polymer samples: Forensic implications for pressure sensitive tape chemical analysis. Talanta 2021; 231:122333. [PMID: 33965014 DOI: 10.1016/j.talanta.2021.122333] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 03/18/2021] [Accepted: 03/19/2021] [Indexed: 11/29/2022]
Abstract
Flowing atmospheric pressure afterglow (FAPA) mass spectrometry (MS) is an easy-to-use, cost-effective, and potentially portable technique that allows direct desorption/ionization from samples with little-to-no sample preparation for real-time chemical analysis. However, it has limitations regarding analytes with low desorption efficiency, such as polymers. Here, laser assisted sampling (LAS) is developed and coupled to FAPA MS to allow access to a wider range of chemical information from polymer samples. This is achieved through laser-induced pyrolysis conditions that provide a much higher degree of spatio-temporal control compared to typical pyrolysis techniques. LAS FAPA MS, together with direct desorption FAPA MS, is implemented on pressure sensitive adhesive (PSA) tape samples, which are often found at crime scenes and recovered as forensic evidence. Comparative PSA tape examination is typically performed to assess any differences in the comparison of unknown and known samples and provide an evidentiary association between suspects and crime scenes in forensic applications. PSA tape samples from several manufacturers of duct, masking, and electrical tape were analyzed from the adhesive and backing side. Direct desorption FAPA provides top-surface selectivity and the tape mass spectra are dominated by more peaks at lower m/z, many of which correspond to polymer additives. LAS gives access to sampling from all of the tape layers and the FAPA mass spectra is extended to higher m/z, while polymer fragmentation patterns are evident. Principal components analysis (PCA) was implemented to assess the ability of each technique to distinguish and categorize identified tape classes within the sampled population. The complementary nature of the resulting mass spectra from direct desorption vs LAS FAPA was evident from the PCA as different tape brands sub-sets were discriminated by each technique. The differentiation obtained by combining both methods is already competitive, or better, than conventional techniques, with the additional benefits of AMS.
Collapse
Affiliation(s)
- Maureen Oliva
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, 79409-1061, USA; Department of Environmental Toxicology, Institute for Forensic Science, Texas Tech University, Lubbock, TX, 79414, USA
| | - Dong Zhang
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, 79409-1061, USA
| | - Paola Prada-Tiedemann
- Department of Environmental Toxicology, Institute for Forensic Science, Texas Tech University, Lubbock, TX, 79414, USA
| | - Gerardo Gamez
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, 79409-1061, USA.
| |
Collapse
|
14
|
Zhang D, Latif M, Gamez G. Instantaneous Differentiation of Functional Isomers via Reactive Flowing Atmospheric Pressure Afterglow Mass Spectrometry. Anal Chem 2021; 93:9986-9994. [PMID: 34251188 DOI: 10.1021/acs.analchem.0c04867] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Ambient mass spectrometry (AMS) allows direct desorption and ionization of analytes in real time with minimal-to-no sample preparation. However, it may present inadequate capabilities for differentiating isomers. Here, a reactive flowing atmospheric-pressure afterglow (reactive-FAPA) AMS source is developed for rapid isomer differentiation by derivatization of analytes in real time. The effects of the reactive-FAPA operating conditions on the reagent and product ions were studied and optimized for highly volatile and non-volatile model compounds with different carbonyl functional groups. In addition, two functional isomers of valproic acid (VPA) metabolites, 4-ene VPA and γ-valprolactone, are successfully differentiated for the first time by incorporating methylamine (MA) reagent vapor into the plasma effluent used for desorption/ionization. Reactive-FAPAMS for 4-ene VPA shows only detectable peaks of the protonated acylation product [M + MA-H2O + H]+, while for γ-valprolactone, it shows detectable peaks for both protonated acylation product [M + MA-H2O + H]+ and protonated intermediate [M + MA + H]+. A method for quantitative characterization of mixtures of 4-ene VPA and γ-valprolactone is also developed and validated. In addition, reactive-FAPAMS also shows better detection sensitivity compared to nonreactive-FAPAMS for some larger analyte types, such as UV filters and steroids. The limit of detection (LOD) of pregnenolone acetate in reactive-FAPAMS is 310 ng/mL, which is about 10 times better than its LOD in nonreactive-FAPA.
Collapse
Affiliation(s)
- Dong Zhang
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Mohsen Latif
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Gerardo Gamez
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| |
Collapse
|