Blanco-Vázquez M, Gil-Cazorla R, Barua A, Taneja M, Hanneken L, Shah S. Impact of thermo-mechanical skin treatment on refraction and keratometry in patients with dry eye disease and the implications for cataract surgery. Cont Lens Anterior Eye 2024; 47:102164. [PMID: 38594154 DOI: 10.1016/j.clae.2024.102164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 01/11/2024] [Accepted: 03/30/2024] [Indexed: 04/11/2024]
Abstract
PURPOSE To determine the changes in keratometry measurements and refraction in patients having the thermo-mechanical periorbital skin treatment, Tixel®, to treat dry eye disease (DED). METHODS A multi-centre, prospective, non-masked study was conducted. DED patients were recruited in 3 international centres and were evaluated in 5 visits separated by an interval of 2 weeks except for the last visit which took place after 18 weeks from visit 1. The same clinical examination was performed at all visits: OSDI questionnaire, tear stability, keratometry, best corrected visual acuity and refraction. Tixel® treatment was applied at the first 3 visits. RESULTS 89 participants (24 males/65 females; mean age: 55.0 ± 14.2 years) were included: 20 presented moderate DED symptoms and 69 severe DED symptoms. Significant differences were found for the spherocylindrical refraction (vector analysis) between visit 1 and visits 2 and 3. Following cumulative analysis, 11.86 % and 16.94 % of participants had more than 0.5 dioptre (D) change in mean keratometry and keratometric astigmatism, respectively, at 3 months post-treatment. A total of 5.40 % had a sphere and cylinder change greater than 0.50D and 16.21 % had the axis changed more than 10 degrees (vector analysis). These changes were particularly significant in patients with severe DED symptoms. CONCLUSIONS Keratometry readings and refraction can change following thermo-mechanical skin treatment for DED, especially in those patients with severe DED symptoms. This should be considered as potential errors in intraocular lens calculations may be induced.
Collapse
Affiliation(s)
- Marta Blanco-Vázquez
- Ocular Surface Group, Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain
| | - Raquel Gil-Cazorla
- College of Health & Life Sciences, Aston University, Birmingham, United Kingdom; Midland Eye, Solihull, United Kingdom.
| | - Ankur Barua
- Midland Eye, Solihull, United Kingdom; Birmingham and Midland Eye Centre, City Hospital, Birmingham, United Kingdom
| | | | | | - Sunil Shah
- College of Health & Life Sciences, Aston University, Birmingham, United Kingdom; Midland Eye, Solihull, United Kingdom; Birmingham and Midland Eye Centre, City Hospital, Birmingham, United Kingdom; Khmer Sight Foundation, Phnom Penh, Cambodia
| |
Collapse
|
2
|
Ruan F, Fan Q, Kong W, Zhang W, Dong H, Wei W, Jie Y. Evaluation of tear film in patients with AIDS without opportunistic ocular infections in the era of COVID-19: A case-control study. Indian J Ophthalmol 2024; 72:S409-S414. [PMID: 38317305 DOI: 10.4103/ijo.ijo_1636_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Accepted: 11/22/2023] [Indexed: 02/07/2024] Open
Abstract
PURPOSE The assessment of tear film and ocular surface conditions in patients with acquired immunodeficiency syndrome (AIDS) has been poorly studied thus far. We aim to assess tear film parameters, ocular surface characteristics, and dry eye disease (DED) symptoms of patients with AIDS who did not undergo highly active antiretroviral treatment (HAART). METHODS This case-control study included 154 age-, sex-, and ethnicity-matched healthy controls and patients with AIDS. All participants underwent comprehensive ocular surface assessment and subjective DED symptomology evaluation. Data were collected between March 2022 and July 2022. RESULTS HAART-naïve patients with AIDS had a shorter noninvasive tear film breakup time (median 3.76 vs. 8.54 s), thinner tear film lipid layer thickness (median 73.00 vs. 91.00 nm), and lower Schirmer I test values (median 5.00 mm/5 min vs. 12.00 mm/5 min) (all P < 0.001). Moreover, higher corneal fluorescein staining scores (median 1.00 vs. 0.00) and higher upper, lower, and total meibomian gland grades were observed in AIDS patients (all P < 0.05). Negative correlations between the blood viral load and the Ocular Surface Disease Index score ( r = -3.50, P = 0.027) and the Schirmer I test score ( r = -0.374, P = 0.017) were detected in patients with AIDS. CONCLUSION Altered tear film status was observed in individuals with HAART-naïve AIDS, even when there were no other ocular symptoms present. Therefore, patients with AIDS should be encouraged to undergo comprehensive ocular surface examinations to detect any subclinical tear film alterations occurring.
Collapse
Affiliation(s)
- Fang Ruan
- Department of Ophthalmology, Beijing You'an Hospital, Capital Medical University, Beijing Infectious Eye Disease Diagnosis and Treatment Center, Beijing, China
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Qian Fan
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
- Nankai University Eye Institute, Nankai University, Tianjin, China
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| | - Wenjun Kong
- Department of Ophthalmology, Beijing You'an Hospital, Capital Medical University, Beijing Infectious Eye Disease Diagnosis and Treatment Center, Beijing, China
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Wei Zhang
- Department of Ophthalmology, Beijing You'an Hospital, Capital Medical University, Beijing Infectious Eye Disease Diagnosis and Treatment Center, Beijing, China
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Hongwei Dong
- Department of Ophthalmology, Beijing You'an Hospital, Capital Medical University, Beijing Infectious Eye Disease Diagnosis and Treatment Center, Beijing, China
| | - Wenbin Wei
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Ying Jie
- Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
3
|
Petriček I, Lešin Gaćina D, Tomić M, Bulum T, Bešlić I, Vidas Pauk S. Post-Blink Blur Time-A Simple Test to Detect Dry Eye-Related Visual Disturbances. J Clin Med 2024; 13:2473. [PMID: 38731003 PMCID: PMC11084590 DOI: 10.3390/jcm13092473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 04/18/2024] [Accepted: 04/22/2024] [Indexed: 05/13/2024] Open
Abstract
Background: Dry eye disease (DED) stands out as one of the most common eye conditions encountered in clinical settings. This study aimed to determine the diagnostic ability and feasibility of post-blink blur time (PBBT) in detecting patients with DED symptoms. Methods: The study included 200 subjects, 100 with and 100 without DED symptoms defined by the Schein questionnaire, who underwent assessment of DED signs [visual acuity, PBBT, conjunctival hyperemia, lid-parallel conjunctival folds-LIPCOF, tear film break-up time-TBUT, fluorescein corneal staining, and meibum score]. Results: DED subjects had a lower PBBT than controls (p < 0.001), with subjective (6 (1-45) s vs. 8 (1-70) s) and objective (6 (2-33) s vs. 8 (2-50) s) PBBT measurements being similar between repeats. The correlations between subjective and objective PBBT measurements were significantly positive (R = 0.873, p < 0.001). Subjective PBBT was negatively related to the Schein questionnaire (R = -0.217, p = 0.002), conjunctival hyperemia (R = -0.105, p = 0.035), and corneal staining (R = -0.153, p = 0.031), while positively related to the TBUT (R = 0.382, p < 0.001) and meibum score (R = 0.106, p = 0.033). Logistic regression analysis showed DED symptoms were significantly associated with subjective PBBT (AOR 0.91, p = 0.001), TBUT (AOR 0.79, p < 0.001), meibum score (AOR 0.65, p = 0.008), LIPCOF (AOR 1.18, p = 0.002) and corneal staining (AOR 1.14, p = 0.028). Conclusions: Subjective self-reported PBBT is a reliable and non-invasive screening test for evaluating time-wise changes in visual acuity and detecting a tear film dysfunction.
Collapse
Affiliation(s)
- Igor Petriček
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
- School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Dina Lešin Gaćina
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
| | - Martina Tomić
- Department of Diabetes and Endocrinology, Vuk Vrhovac University Clinic for Diabetes, Endocrinology and Metabolic Diseases, Merkur University Hospital, 10000 Zagreb, Croatia
| | - Tomislav Bulum
- School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
- Department of Diabetes and Endocrinology, Vuk Vrhovac University Clinic for Diabetes, Endocrinology and Metabolic Diseases, Merkur University Hospital, 10000 Zagreb, Croatia
| | - Iva Bešlić
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
| | - Sania Vidas Pauk
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
| |
Collapse
|
4
|
Pena-Verdeal H, Garcia-Queiruga J, Sabucedo-Villamarin B, Garcia-Resua C, Giraldez MJ, Yebra-Pimentel E. A Comprehensive Study on Tear Meniscus Height Inter-Eye Differences in Aqueous Deficient Dry Eye Diagnosis. J Clin Med 2024; 13:659. [PMID: 38337353 PMCID: PMC10856492 DOI: 10.3390/jcm13030659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/18/2024] [Accepted: 01/22/2024] [Indexed: 02/12/2024] Open
Abstract
(1) Background: Dry eye disease (DED) is a chronic ocular surface condition that requires precise diagnostic tools. The present study aimed to investigate the diagnostic potential of the absolute inter-eye difference (|OD-OS|) in tear meniscus height (TMH) for the detection of the presence of aqueous deficient dry eye (ADDE). (2) Methods: A sample of 260 participants with dry eye complaints underwent ocular surface examinations thorough diagnostic assessments based on the Tear Film and Ocular Surface Society guidelines (TFOS DEWS II). Participants were subsequently categorized as No ADDE and ADDE based on TMH. Statistical analyses to determine the optimal TMH|OD-OS| cut-off value in a randomly selected study group (200 participants) were performed, while a separate validation analysis of the cut-off value obtained in a random cross-validation group (60 participants) was also performed. (3) Results: The significant diagnostic capability of TMH|OD-OS| (area under the curve = 0.719 ± 0.036, p < 0.001) was found. The identified cut-off value of 0.033 mm demonstrated reliable specificity (77.6%) and moderate sensitivity (59.1%). Cross-validation confirmed the cut-off value's association with the TFOS DEWS II diagnostic criterion (Cramer's V = 0.354, p = 0.006). (4) Conclusions: The present study provides evidence for the diagnostic potential of TMH|OD-OS| in identifying ADDE. The identified cut-off value enhances the specificity and offers moderate sensitivity, providing an objective tool for clinical decision making.
Collapse
Affiliation(s)
- Hugo Pena-Verdeal
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| | - Jacobo Garcia-Queiruga
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| | - Belen Sabucedo-Villamarin
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
| | - Carlos Garcia-Resua
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| | - Maria J. Giraldez
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| | - Eva Yebra-Pimentel
- GI-2092—Optometría, Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Campus Vida S/N, 15705 Santiago de Compostela, Spain; (B.S.-V.); (C.G.-R.); (M.J.G.); (E.Y.-P.)
- Instituto de Investigación Sanitaria (IDIS), Travesía da Choupana S/N, 15706 Santiago de Compostela, Spain
| |
Collapse
|
5
|
Huang T, Wang Y, Zhu Z, Wu Q, Chen D, Li Y. Moisture chamber goggles for the treatment of postoperative dry eye in patients receiving SMILE and FS-LASIK surgery. BMC Ophthalmol 2023; 23:501. [PMID: 38066467 PMCID: PMC10709852 DOI: 10.1186/s12886-023-03241-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 11/23/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND The incidence of refractive surgery-related dry eye disease (DED) is rising due to the increasing popularity of corneal refractive surgery. The moisture chamber goggles (MCGs) have been shown to tear evaporation by increasing local humidity and minimizing airflow. The current study aims to evaluate the efficacy of moisture chamber goggles for refractive surgery-related DED. METHODS In this nonrandomized open-label controlled study, 78 participants (156 eyes) receiving refractive surgery were enrolled between July 2021 and April 2022, and sequentially allocated to MGC and control groups. 39 participants were allocated to the MGC groups, of which 53.8% received small-incision lenticule extraction (SMILE) and 46.2% received femtosecond laser-assisted in situ keratomileusis (FS-LASIK), and were instructed to wear MCGs for the duration of 1 month postoperatively, in addition to the standard postoperative treatment received by the control groups (56.4% SMILE, 43.6% FS-LASIK). Participants underwent full ophthalmic examinations, including visual acuity, manifest refraction, DED evaluations, and higher-order aberrations (HOAs), both preoperatively and at routine follow-ups 1 day, 1 week, and 1 month after surgery. DED parameters included non-invasive tear film break-up time (NIBUT), tear meniscus height (TMH), conjunctival congestion, lipid layer thickness (LLT), and ocular surface disease index (OSDI) questionnaires. Student's t-test was used for comparisons between control and MCG groups, and between preoperative and postoperative parameters within groups. RESULTS Postoperative NIBUT decreased in both SMILE and FS-LASIK control groups 1 day after the surgery (SMILE, P = 0.001; FS-LASIK, P = 0.008), but not in the corresponding MCG groups (SMILE, P = 0.097; FS-LASIK, P = 0.331). TMH in the MCG group was significantly higher at 1 week (P = 0.039) and 1 month (P = 0.015) in SMILE, and 1 day (P = 0.003) in FS-LASIK groups. In FS-LASIK participants, significantly lower HOAs and coma levels in the MCG group were observed 1 day (total HOAs, P = 0.023; coma, P = 0.004) and 1 week (total HOAs, P = 0.010, coma, P = 0.004) after surgery. No consistent statistically significant intergroup difference was observed between MCG and control groups in conjunctival congestion, LLT, and OSDI. CONCLUSIONS MCGs effectively slowed tear evaporation, increased tear film stability, and improved HOAs in patients receiving SMILE and FS-LASIK surgeries. MCG is an effective adjuvant therapy in the comprehensive management of refractive surgery-related DED.
Collapse
Affiliation(s)
- Tianze Huang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China
| | - Yuchen Wang
- Department of Ophthalmology, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310003, Zhejiang, China
| | - Zhou Zhu
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China
| | - Qingyang Wu
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China
| | - Di Chen
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China
| | - Ying Li
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China.
| |
Collapse
|
6
|
Shi GL, Pan AP, Hu RL, Zhang YQ, Ma YJ, Yu AY. Preliminary Application of a Continuous Functional Contrast Visual Acuity System in the Assessment of Visual Function in Dry Eye Patients. Transl Vis Sci Technol 2023; 12:6. [PMID: 38054930 PMCID: PMC10702783 DOI: 10.1167/tvst.12.12.6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 10/29/2023] [Indexed: 12/07/2023] Open
Abstract
Purpose To investigate the feasibility and efficacy of a continuous functional contrast visual acuity (CFCVA) system in the assessment of visual function in dry eye disease (DED). Methods Twenty patients with DED and 15 normal controls were recruited. Subjective symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, and tear film stability was assessed by a noninvasive corneal topographer. Under natural blinking conditions, the custom-built CFCVA system was used to take serial visual acuity measurements at 100%, 25%, 10%, and 5% contrast for 60 seconds. A 5-minute measurement at a 100% contrast level was defined as the stress test (ST). Mean CFCVA was defined, and visual maintenance ratio (VMR) was the ratio of mean CFCVA divided by baseline visual acuity. Results In both groups, VMR decreased and mean CFCVA (logarithm of the minimum angle of resolution) increased with decreasing optotype contrast (from 100% to 5%). In ST, the ST VMR at the fourth and fifth minutes (VMR54 and VMR55) showed the strongest correlations with OSDI total, ocular symptoms, and vision-related function (-0.646 and -0.598, -0.688 and -0.693, and -0.599 and -0.555, respectively, P < 0.05). VMR54 and VMR55 also demonstrated the best discriminating ability for detecting DED, with areas under the curve of 0.903 and 0.867, respectively. Conclusions Extending the continuous measuring time was more effective for detecting vision-related functional abnormalities in patients with DED than simply decreasing the optotype contrast level. Translational Relevance The proposed CFCVA system and associated parameters offer a potential method for quantifying and interpreting the visual symptoms of DED in clinical care.
Collapse
Affiliation(s)
- Gui-Lian Shi
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - An-Peng Pan
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Rui-Lin Hu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | | | - Yun-Jing Ma
- Tianjin Branch of National Clinical Research Center for Ocular Disease, Tianjin, China
- Tianjin Medical University Eye Hospital, Tianjin, China
| | - A-Yong Yu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| |
Collapse
|
7
|
Fujio K, Nagino K, Huang T, Sung J, Akasaki Y, Okumura Y, Midorikawa-Inomata A, Fujimoto K, Eguchi A, Miura M, Hurramhon S, Yee A, Hirosawa K, Ohno M, Morooka Y, Murakami A, Kobayashi H, Inomata T. Clinical utility of maximum blink interval measured by smartphone application DryEyeRhythm to support dry eye disease diagnosis. Sci Rep 2023; 13:13583. [PMID: 37604900 PMCID: PMC10442434 DOI: 10.1038/s41598-023-40968-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Accepted: 08/19/2023] [Indexed: 08/23/2023] Open
Abstract
The coronavirus disease (COVID-19) pandemic has emphasized the paucity of non-contact and non-invasive methods for the objective evaluation of dry eye disease (DED). However, robust evidence to support the implementation of mHealth- and app-based biometrics for clinical use is lacking. This study aimed to evaluate the reliability and validity of app-based maximum blink interval (MBI) measurements using DryEyeRhythm and equivalent traditional techniques in providing an accessible and convenient diagnosis. In this single-center, prospective, cross-sectional, observational study, 83 participants, including 57 with DED, had measurements recorded including slit-lamp-based, app-based, and visually confirmed MBI. Internal consistency and reliability were assessed using Cronbach's alpha and intraclass correlation coefficients. Discriminant and concurrent validity were assessed by comparing the MBIs from the DED and non-DED groups and Pearson's tests for each platform pair. Bland-Altman analysis was performed to assess the agreement between platforms. App-based MBI showed good Cronbach's alpha coefficient, intraclass correlation coefficient, and Pearson correlation coefficient values, compared with visually confirmed MBI. The DED group had significantly shorter app-based MBIs, compared with the non-DED group. Bland-Altman analysis revealed minimal biases between the app-based and visually confirmed MBIs. Our findings indicate that DryEyeRhythm is a reliable and valid tool that can be used for non-invasive and non-contact collection of MBI measurements, which can assist in accessible DED detection and management.
Collapse
Affiliation(s)
- Kenta Fujio
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Ken Nagino
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
- Department of Hospital Administration, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Tianxiang Huang
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Jaemyoung Sung
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Yasutsugu Akasaki
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Yuichi Okumura
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Akie Midorikawa-Inomata
- Department of Hospital Administration, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Keiichi Fujimoto
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Atsuko Eguchi
- Department of Hospital Administration, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Maria Miura
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Shokirova Hurramhon
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Alan Yee
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Kunihiko Hirosawa
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Mizu Ohno
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Yuki Morooka
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Akira Murakami
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Hiroyuki Kobayashi
- Department of Hospital Administration, Juntendo University Graduate School of Medicine, Tokyo, Japan
| | - Takenori Inomata
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan.
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
- Department of Hospital Administration, Juntendo University Graduate School of Medicine, Tokyo, Japan.
- AI Incubation Farm, Juntendo University Graduate School of Medicine, Tokyo, Japan.
| |
Collapse
|
8
|
Singh S, Srivastav S, Thacker M, Bokara KK, Singh V, Basu S. Repeatability of Non-invasive Tear Film Evaluation in Healthy Rabbit Eyes. Curr Eye Res 2023; 48:699-703. [PMID: 37025013 DOI: 10.1080/02713683.2023.2200915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/30/2023] [Accepted: 04/05/2023] [Indexed: 04/08/2023]
Abstract
PURPOSE The current study investigated the normative data values and repeatability of non-invasive tear film tests using Oculus Keratograph 5M in rabbit eyes. METHODS Triplicate analysis of tear film parameters [tear meniscus height (TMH), non-invasive tear break up time (NIBUT), bulbar congestion, meibography] of 38 healthy adults New Zealand white rabbits (mean age, 13 ± 4.7 months) was performed using Oculus keratograph 5M (K5M). Bland-Altman analysis was used for testing repeatability. RESULTS Thirty-eight rabbits (N = 76 eyes) weighing 2.5 ± 0.4 kg were studied. The mean NIBUT values of the right and left eye were 14.3 ± 5.8 and 12.3 ± 5.8 s, respectively. The mean central TMH values were 0.43 ± 0.23 and 0.33 ± 0.14 mm in the right and left eye, respectively. Meibography showed closely placed, wide meibomian glands running vertically with no distorted or gland loss areas. There were no differences between the eyes for the above parameters. Bland-Altman plot showed good repeatability for both NIBUT and TMH values. CONCLUSION The non-invasive tear film parameters show good repeatability using keratograph 5M and can be used as an objective parameter for rabbit ocular surface experiments.
Collapse
Affiliation(s)
- Swati Singh
- Ophthalmic Plastic Surgery Services, L V Prasad Eye Institute, Hyderabad, India
- Centre for Ocular Regeneration, L V Prasad Eye Institute, Hyderabad, India
| | - Saumya Srivastav
- Brien Holden Center for Eye Research (BHERC), L V Prasad Eye Institute, Hyderabad, India
| | - Minal Thacker
- Centre for Ocular Regeneration, L V Prasad Eye Institute, Hyderabad, India
- Brien Holden Center for Eye Research (BHERC), L V Prasad Eye Institute, Hyderabad, India
| | - Kiran K Bokara
- Centre for Cellular and Molecular Biology, Hyderabad, India
| | - Vivek Singh
- Brien Holden Center for Eye Research (BHERC), L V Prasad Eye Institute, Hyderabad, India
| | - Sayan Basu
- Centre for Ocular Regeneration, L V Prasad Eye Institute, Hyderabad, India
- Brien Holden Center for Eye Research (BHERC), L V Prasad Eye Institute, Hyderabad, India
- The Shantilal Shanghvi Cornea Institute, L V Prasad Eye Institute, Hyderabad, India
| |
Collapse
|
9
|
Capote-Puente R, Bautista-Llamas MJ, Sánchez-González JM. Tear Film Dynamics between Low and High Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) Score with a Lehfilcon A Silicone Hydrogel Water Gradient Contact Lens: A Non-Invasive Methodology Approach. Diagnostics (Basel) 2023; 13:diagnostics13050939. [PMID: 36900083 PMCID: PMC10001148 DOI: 10.3390/diagnostics13050939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 02/16/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023] Open
Abstract
The purpose of this study is to evaluate the tear film dynamics between individuals with low and high Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) scores when wearing Lehfilcon A silicone hydrogel water gradient contact lenses. In this study, we implemented a longitudinal, single-location, self-comparison investigation. Variables measured included conjunctival redness, lipid layer thickness, tear meniscus height, first and mean non-invasive break-up time, CLDEQ-8, and standard patient evaluation of eye dryness (SPEED). In the second phase, participants were re-evaluated after 30 days of wearing the contact lenses to assess the tear film wearing the lenses. In a longitudinal comparison by group, we found that lipid layer thickness decreased 1.52 ± 1.38 (p < 0.01) and 0.70 ± 1.30 (p = 0.01) Guillon patterns degrees in the low and high CLDEQ-8 group, respectively. MNIBUT increased in 11.93 ± 17.93 (p < 0.01) and 7.06 ± 12.07 (p < 0.01) seconds. Finally, LOT increased in 22.19 ± 27.57 (p < 0.01) and 16.87 ± 25.09 (p < 0.01). In conclusion, this study demonstrates the effectiveness of Lehfilcon A silicone hydrogel water gradient contact lenses in improving tear film stability and reducing subjective dry eye symptoms in individuals with low and high CLDEQ-8 scores. However, it also led to an increase in conjunctival redness and a decrease in tear meniscus height.
Collapse
|
10
|
Barrientos RT, Godín F, Rocha-De-Lossada C, Soifer M, Sánchez-González JM, Moreno-Toral E, González AL, Zein M, Larco P, Mercado C, Piedrahita MA. Ophthalmological Approach for the Diagnosis of Dry Eye Disease in Patients with Sjögren's Syndrome. LIFE (BASEL, SWITZERLAND) 2022; 12:life12111899. [PMID: 36431034 PMCID: PMC9692499 DOI: 10.3390/life12111899] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 11/13/2022] [Accepted: 11/14/2022] [Indexed: 11/17/2022]
Abstract
Dry eye has two basic subdivisions: aqueous deficient dry eye (ADDE), with SS a major cause; and evaporative dry eye (EDE), due to either intrinsic or extrinsic factors. SS is a chronic inflammatory disorder defined by dysfunction of the exocrine glands leading to dry eye and dry mouth. The objective of this article was to carry out a systematic and critical review of several scientific publications on dry eye disease, with the aim of providing general recommendations to distinguish dry eye and its different variants in patients with SS, during the period 1979 to 2020, using search engines for articles indexed in Scopus, Latindex, Scielo, Clinical Trials, Medline, Embase, and Cochrane, allowing the analysis of 132 articles published in indexed journals on the subject of dry eye disease and SS, evidencing its conceptualization, prevalence, risk factors, etiopathogenesis, clinical manifestations, diagnosis, and treatment.
Collapse
Affiliation(s)
| | - Fernando Godín
- Department of Ophthalmology, Research and Ocular Health Group, Unbosque, University of El Bosque, Bogota 110111, Colombia
| | - Carlos Rocha-De-Lossada
- Department of Ophthalmology, Qvision, VITHAS Almería Hospital, 04120 Almeria, Spain
- Department of Ophthalmology, Regional Universitary Hospital of Málaga, 18014 Granada, Spain
- Department of Surgery, Ophthalmology Area, University of Seville, 41012 Seville, Spain
- Department of Opthalmology, Vithas Malaga, 29016 Malaga, Spain
| | - Matias Soifer
- Department of Ophthalmology, National Eye Institute, National Institute of Health, Bethesda, MD 20892, USA
| | - José-María Sánchez-González
- Department of Physics of Condensed Matter, Optics Area, University of Seville, 41012 Seville, Spain
- Correspondence:
| | - Esteban Moreno-Toral
- Department of Pharmacy and Pharmaceutical Technology, University of Seville, 41012 Seville, Spain
| | - Ana-Luisa González
- Department of Ophthalmology, Research Department Clínica La Luz, Lima 15046, Peru
| | - Mike Zein
- Department of Ophthalmology, Bascom Palmer Eye Institute, School of Medicine, University of Miami Miller, Miami, FL 33136, USA
| | - Pablo Larco
- Department of Ophthalmology, Bascom Palmer Eye Institute, School of Medicine, University of Miami Miller, Miami, FL 33136, USA
| | - Carolina Mercado
- Department of Ophthalmology, Bascom Palmer Eye Institute, School of Medicine, University of Miami Miller, Miami, FL 33136, USA
| | | |
Collapse
|