1
|
Ajdari B, Madrakian T, Afkhami A. Development of an electrochemical sensor utilizing MWCNs-poly(2-aminothiophenol) @AgNPs nanocomposite for the simultaneous determination of Pb 2+ and Cd 2+ in food samples. Food Chem 2025; 477:143529. [PMID: 40023026 DOI: 10.1016/j.foodchem.2025.143529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2024] [Revised: 02/19/2025] [Accepted: 02/19/2025] [Indexed: 03/04/2025]
Abstract
This study focuses on the synthesis and characterization of the Multiwall Carbon Nanotubes-Poly(2-aminothiophenol) @silver nanoparticles nanocomposite (MWCNTs-PATP@AgNPs) using different analytical methods. The synthesized MWCNTs-PATP@AgNPs served as an electrocatalytic modifier, enabling the highly selective and sensitive detection of Pb2+ and Cd2+ ions at nanomolar levels using square wave anodic stripping voltammetry. The concentration of MWCNTs- PATP @AgNPs, the type and concentration of the electrolyte, the solution's pH, and the preconcentration conditions, were systematically optimized. A linear response was observed for Pb2+ and Cd2+ within the ranges of 0.5-60.0 nmolL-1 and 8.0-50.0 nmol L-1, respectively, with detection limits of 0.125 nmol L-1 for Pb2+ and 1.47 nmol L-1 for Cd2+. Furthermore, the MWCNTs-PATP@AgNPs sensor demonstrated the capability to selectively detect these target metals in the presence of various common interfering species. The sensor was effectively utilized for the detection of Pb2+ and Cd2+ ions across various real samples.
Collapse
Affiliation(s)
- Beheshteh Ajdari
- Department of Analytical Chemistry, Faculty of Chemistry and Petroleum Sciences, Bu-Ali Sina University, Hamedan, 6517838695, Iran
| | - Tayyebeh Madrakian
- Department of Analytical Chemistry, Faculty of Chemistry and Petroleum Sciences, Bu-Ali Sina University, Hamedan, 6517838695, Iran.
| | - Abbas Afkhami
- Department of Analytical Chemistry, Faculty of Chemistry and Petroleum Sciences, Bu-Ali Sina University, Hamedan, 6517838695, Iran
| |
Collapse
|
2
|
Gopika MG, Saraswathyamma B, Govindasamy M. CuSeO 3@f-CNFs: A superoxide nanozyme for the selective nanomolar determination of the key cardiovascular biomarker, Glutathione. Talanta 2025; 287:127621. [PMID: 39879799 DOI: 10.1016/j.talanta.2025.127621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2024] [Revised: 01/14/2025] [Accepted: 01/22/2025] [Indexed: 01/31/2025]
Abstract
Nanocomposites that mimic the characteristics of enzymes, commonly as nanozymes, can function as an efficient sensing material with high selectivity towards the targeted biological macromolecule. These nanozymes overcome of the challenges that arise when using natural enzymes as sensing material. This study presents a novel nanozyme, Copper Selenite (CuSeO3) nanoparticles mounted on f-CNF, to electrochemically determine a potential cardiovascular biomarker, Glutathione (GSH). The choice of this material is due to the well-known ability of GSH to form a complex with copper. When a Cu ion enters a healthy cell, it quickly forms a complex with GSH, which then moves to another storage molecule: either a metalloprotein or a chelator. CNF was functionalized using acid to generate functionalized-CNF to enhance biocompatibility and boost conductivity. This was done to provide many active sites for effective integration of CuSeO3 in the nanocomposite preparation. The glassy carbon electrode (GCE) surface was enhanced by introducing CuSeO3@f-CNF nanocomposite, resulting in a significant increase in the current response for GSH in comparison to prior research. CuSeO3@f-CNF/GCE sensor has shown excellent sensing properties, like enhanced stability, selectivity, sensitivity, and reproducibility, for detecting and quantifying GSH. The sensor demonstrated an extensive linear detection range from 62.5 nM to 7785.0 μM, signifying one of the most comprehensive ranges documented to date. It attained a remarkable detection limit (LOD) of 17.6 nM. The sensor's performance was further tested by analyzing genuine biological fluid samples. The nanozyme-modified GCE demonstrated exceptional electrocatalytic efficiency for GSH detection, making it extremely appropriate for real-time monitoring applications.
Collapse
Affiliation(s)
- M G Gopika
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri Campus, Clappana P O, Kollam, Kerala, 690525, India
| | - Beena Saraswathyamma
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri Campus, Clappana P O, Kollam, Kerala, 690525, India.
| | - Mani Govindasamy
- International Ph. D Program in Innovative Technology of Biomedical Engineering & Medical Devices, Ming Chi University of Technology, New Taipei City 243303, Taiwan; Research Center for Intelligence Medical Devices, Ming Chi University of Technology, New Taipei City 243303, Taiwan.
| |
Collapse
|
3
|
Chaúque BJM, de Amorim Nascimento FL, Silva KJS, Hoff RB, Goldim JR, Rott MB, Zanette RA, Verruck S. Solar-based technologies for removing potentially toxic metals from water sources: a review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2025; 32:3503-3530. [PMID: 39821874 DOI: 10.1007/s11356-025-35897-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Accepted: 01/02/2025] [Indexed: 01/19/2025]
Abstract
Technological advances have led to a proportional increase in the deposition of contaminants across various environmental compartments, including water sources. Heavy metals, also known as potentially toxic metals, are of particular concern due to their significant harmful impacts on environmental and human health. Among the available methods for mitigating the threat of these metals in water, solar radiation-based technologies stand out for their cleanliness, cost-effectiveness, and efficiency in removing or reducing the toxicity of heavy metals. The performance and productivity of these methods in removing heavy metals such as arsenic (As), chromium (Cr), mercury (Hg), and uranium (U) from water still need to be comprehensively synthesized. Thus, this work aims to address that gap. The performance, potential, and challenges of real-world applications of conventional solar stills (CSS), membrane-based solar stills, and solar heterogeneous photocatalysis are concisely summarized and critically reviewed. CSS and membrane-based stills are highly effective (efficacy > 98%) in removing and capturing heavy metals from water. However, structural and functional improvements are needed to enhance productivity (especially for CSS) and usability in real-world environmental remediation and drinking water supply scenarios. Solar heterogeneous photocatalysis is highly effective in removing and/or converting As, Cr, Hg, and U into their non-toxic or less toxic forms, which subsequent processes can easily remove. Further research is necessary to evaluate the safety of photocatalytic materials, their integration into scalable solar reactors, and their usability in real-world environmental remediation applications.
Collapse
Affiliation(s)
- Beni Jequicene Mussengue Chaúque
- Mestrado Profissional Em Pesquisa Clínica, Master's Program in Clinical Research (MPPC) at the Hospital de Clínicas de Porto Alegre (HCPA) (CAPES Pilot Program), Porto Alegre, Rio Grande Do Sul, Brazil.
- Postgraduate Program in Biological Sciences: Pharmacology and Therapeutics, Universidade Federal do Rio Grande do Sul, Porto Alegre, Rio Grande Do Sul, Brazil.
- Center of Studies in Science and Technology (NECET), Biology Course, Universidade Rovuma, Niassa, Lichinga, Mozambique.
| | - Francisco Lucas de Amorim Nascimento
- Departamento de Zootecnia E Desenvolvimento Rural, Universidade Federal de Santa Catarina, Rod. Admar Gonzaga, 1346, Itacorubi, Florianópolis, SC, 88034-001, Brazil
| | | | - Rodrigo Barcellos Hoff
- Advanced Laboratory Section of Santa Catarina (SLAV/SC), Ministry of Agriculture and Livestock (MAPA), R. João Grumiche, 117 - Bloco T, São José, Santa Catarina, 88102-600, Brazil
| | - José Roberto Goldim
- Master's Program in Clinical Research (MPPC) at the Hospital de Clínicas de Porto Alegre (HCPA) (CAPES Pilot Program), Porto Alegre, Rio Grande Do Sul, Brazil
| | - Marilise Brittes Rott
- Protozoology Laboratory, Microbiology Immunology and Parasitology Department, Basic Health Sciences Institute, Federal University of Rio Grande Do Sul, Ramiro Barcelos Street, N 2600, Porto Alegre, Rio Grande Do Sul, 90035-002, Brazil
| | - Régis Adriel Zanette
- Postgraduate Program in Biological Sciences: Pharmacology and Therapeutics, Universidade Federal do Rio Grande do Sul, Porto Alegre, Rio Grande Do Sul, Brazil
| | - Silvani Verruck
- Departamento de Ciência E Tecnologia de Alimentos, Universidade Federal de Santa Catarina, Rod. Admar Gonzaga, 1346, Itacorubi, Florianópolis, Santa Catarina, 88034-001, Brazil
| |
Collapse
|
4
|
De Chiara B, Del Duca F, Hussain MZ, Kratky T, Banerjee P, Dummert SV, Khoshouei A, Chanut N, Peng H, Al Boustani G, Hiendlmeier L, Jinschek J, Ameloot R, Dietz H, Wolfrum B. Laser-Induced Metal-Organic Framework-Derived Flexible Electrodes for Electrochemical Sensing. ACS APPLIED MATERIALS & INTERFACES 2025; 17:3772-3784. [PMID: 39762089 PMCID: PMC11744510 DOI: 10.1021/acsami.4c18243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2024] [Revised: 12/18/2024] [Accepted: 12/23/2024] [Indexed: 01/18/2025]
Abstract
The successful development of a metal-organic framework (MOF)-derived Co/Co3O4/C core-shell composite integrated into laser-induced graphitic (LIG) carbon electrodes for electrochemical sensing is reported. The sensors are fabricated via a direct laser scribing technique using a UV laser (355 nm wavelength) to induce the photothermolysis of rationally selected ZIF-67 into the LIG matrix. Electrochemical characterization reveals that the incorporation of the laser-scribed ZIF-67-derived composite on the electrode surface reduces the impedance more than 100 times compared with bare LIG sensors. Comprehensive morphological, structural, and chemical analyses confirm the formation of porous LIG from the laser irradiation of polyimide, while the LIG+ZIF-67-derived composites feature size-controlled and uniformly distributed Co/Co3O4 core/shell nanoparticles (NPs) in the semihollow wasp-nest-like carbon matrix from photothermal decomposition of ZIF-67, embedded within the LIG electrode area. The high surface area and porosity of this ZIF-67-derived nitrogen-rich carbon facilitate charge transfer processes, whereas size-controlled Co/Co3O4 core/shell NPs offer accessible electrochemical active sites, making these LIG+ZIF-67-derived composite-based sensors promising materials for applications requiring high charge injection capability and low electrode/electrolyte interface impedance. The PI+Z67L sensor exhibited a 400 times higher specific capacitance (2.4 mF cm-2) compared to the PIL sensor (6 μF cm-2). This laser scribing approach enables the rapid and cost-effective fabrication of high-performance electrochemical sensors enhanced by the integration of tailored MOF-derived composites.
Collapse
Affiliation(s)
- Beatrice De Chiara
- Neuroelectronics,
Munich Institute of Biomedical Engineering, Department of Electrical
Engineering, School of Computation, Information and Technology, Technical University of Munich, Hans-Piloty-Str. 1, 85748 Garching, Germany
| | - Fulvia Del Duca
- Neuroelectronics,
Munich Institute of Biomedical Engineering, Department of Electrical
Engineering, School of Computation, Information and Technology, Technical University of Munich, Hans-Piloty-Str. 1, 85748 Garching, Germany
| | - Mian Zahid Hussain
- Chair
of Inorganic and Metal−Organic Chemistry, Department of Chemistry,
School of Natural Sciences, Technical University
of Munich, Lichtenbergstr. 4, 85748 Garching, Germany
| | - Tim Kratky
- Physical
Chemistry with Focus on Catalysis, Department of Chemistry, School
of Natural Sciences, Technical University
of Munich, Lichtenbergstr 4, 85748 Garching, Germany
| | - Pritam Banerjee
- National
Centre for Nano Fabrication and Characterization (DTU Nanolab), Technical University of Denmark, Fysikvej 307, DK-2800 Kongens Lyngby, Denmark
| | - Sarah V. Dummert
- Chair
of Inorganic and Metal−Organic Chemistry, Department of Chemistry,
School of Natural Sciences, Technical University
of Munich, Lichtenbergstr. 4, 85748 Garching, Germany
| | - Ali Khoshouei
- Laboratory
for Biomolecular Nanotechnology, Department of Biosciences, School
of Natural Sciences, Technical University
of Munich, Am Coulombwall 4a, 85748 Garching, Germany
| | - Nicolas Chanut
- Center for
Membrane Separations, Adsorption, Catalysis, and Spectroscopy (cMACS), KU Leuven, 3001 Leuven, Belgium
| | - Hu Peng
- Neuroelectronics,
Munich Institute of Biomedical Engineering, Department of Electrical
Engineering, School of Computation, Information and Technology, Technical University of Munich, Hans-Piloty-Str. 1, 85748 Garching, Germany
| | - George Al Boustani
- Neuroelectronics,
Munich Institute of Biomedical Engineering, Department of Electrical
Engineering, School of Computation, Information and Technology, Technical University of Munich, Hans-Piloty-Str. 1, 85748 Garching, Germany
| | - Lukas Hiendlmeier
- Neuroelectronics,
Munich Institute of Biomedical Engineering, Department of Electrical
Engineering, School of Computation, Information and Technology, Technical University of Munich, Hans-Piloty-Str. 1, 85748 Garching, Germany
| | - Joerg Jinschek
- National
Centre for Nano Fabrication and Characterization (DTU Nanolab), Technical University of Denmark, Fysikvej 307, DK-2800 Kongens Lyngby, Denmark
| | - Rob Ameloot
- Center for
Membrane Separations, Adsorption, Catalysis, and Spectroscopy (cMACS), KU Leuven, 3001 Leuven, Belgium
| | - Hendrik Dietz
- Laboratory
for Biomolecular Nanotechnology, Department of Biosciences, School
of Natural Sciences, Technical University
of Munich, Am Coulombwall 4a, 85748 Garching, Germany
| | - Bernhard Wolfrum
- Neuroelectronics,
Munich Institute of Biomedical Engineering, Department of Electrical
Engineering, School of Computation, Information and Technology, Technical University of Munich, Hans-Piloty-Str. 1, 85748 Garching, Germany
| |
Collapse
|
5
|
Dominique E, Renault C. Towards the rational design of N-(1,3-dimethylbutyl)- N'-phenyl-1,4-benzenediamine (6PPD) electrochemical sensor. Analyst 2024; 149:5165-5173. [PMID: 39196540 DOI: 10.1039/d4an00973h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2024]
Abstract
N-(1,3-Dimethylbutyl)-N'-phenyl-1,4-benzenediamine (6PPD) is a common additive in tires. 6PPD protects rubber from oxidative damage by ozone. Leaching of 6PPD in the environment leads to the formation of harmful byproducts such as 6PPD quinone. In this work we provide the fundamental basis for the detection of 6PPD by electrochemical techniques. We use cyclic voltammetry to study the adsorption of 6PPD on glassy carbon. We show that adsorbed 6PPD can be reversibly oxidized and reduced without disturbing the adsorption process. This result enables repeated electrochemical titrations. We determine, in neutral condition at 22 °C, an adsorption constant of Kads = 1.2 ± 0.5 μM-1 and kinetics of adsorption kads∈[0.74-5.60] × 104 L mol-1 s-1. Based on this knowledge we demonstrate the lowest concentration of 6PPD ever detected electrochemically, 10 nM. We also identify current challenges for electrochemical sensing of 6PPD. Multiple layers are formed at concentrations above 4.6 μM and the slow kinetics of adsorption requires long (hour) measurement time to reach maximum sensitivity.
Collapse
Affiliation(s)
- Emily Dominique
- Department of Chemistry & Biochemistry, Loyola University Chicago, Flanner Hall, 1068 W Sheridan Road, Chicago, Illinois 60660, USA.
| | - Christophe Renault
- Department of Chemistry & Biochemistry, Loyola University Chicago, Flanner Hall, 1068 W Sheridan Road, Chicago, Illinois 60660, USA.
| |
Collapse
|
6
|
Silva FWL, Bernardino CAR, Ferreira JHA, Mahler CF, Santelli RE, Canevari TC, Cincotto FH. Disposable electrochemical sensor: Highly sensitive determination of nitrofurazone antibiotic in environmental samples and pharmaceutical formulations. CHEMOSPHERE 2024; 361:142481. [PMID: 38823428 DOI: 10.1016/j.chemosphere.2024.142481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 05/27/2024] [Accepted: 05/28/2024] [Indexed: 06/03/2024]
Abstract
The study presents the successful development of a new electrochemical sensor with low cost and disposability for application in nitrofurazone detection in environmental and pharmaceutical samples. The sensors were fabricated using materials obtained from local storage and conductive carbon ink. The modification of the screen-printed electrodes with the hybrid nanomaterial based on silver nanoparticles, carbon quantum dots, and carbon nanotubes showed synergistic contributions in the nitrofurazone electrooxidation, as observed in the wide linear range (0.008 at 15.051 μM), with a sensitivity of 0.650 μA/μM. The limit of detection obtained was 4.6 nM. Differential pulse voltammetry, cyclic voltammetry, X-ray photoelectron spectroscopy, X-ray diffraction analysis, and high-resolution transmission electron microscopy were used to evaluate the electrochemical and structural characteristics. Studies of possible interferences were considered with nitrofurazone in the presence of the ions and organic molecules. The results were satisfactory, with a variation of 93.3% ± 4.39% at 100% ± 2.40%. The low volume used in the analyses (50 μL), disposability, high sensibility, selectivity, and low limit of detection are advantages that make the proposed sensor an electrochemical tool of high viability for the NFZ detection in environmental matrices and pharmaceutical formulations.
Collapse
Affiliation(s)
- Francisco Walison Lima Silva
- Departamento de Química Analítica, Instituto de Química, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | | | - João H A Ferreira
- LabNaHm: Multifunctional Hybrid Nanomaterials Laboratory. Engineering School, Mackenzie Presbyterian University, 01302-907, São Paulo, SP, Brazil
| | - Claudio Fernando Mahler
- Departamento de Engenharia Civil, COPPE, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Ricardo Erthal Santelli
- Departamento de Química Analítica, Instituto de Química, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil; National Institute of Science & Technology of Bioanalytics (INCTBio), Campinas, Brazil
| | - Thiago C Canevari
- LabNaHm: Multifunctional Hybrid Nanomaterials Laboratory. Engineering School, Mackenzie Presbyterian University, 01302-907, São Paulo, SP, Brazil.
| | - Fernando Henrique Cincotto
- Departamento de Química Analítica, Instituto de Química, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil; National Institute of Science & Technology of Bioanalytics (INCTBio), Campinas, Brazil.
| |
Collapse
|
7
|
Gorain B, Karmakar V, Sarkar B, Dwivedi M, Leong JTL, Toh JH, Seah E, Ling KY, Chen KY, Choudhury H, Pandey M. Biomacromolecule-based nanocarrier strategies to deliver plant-derived bioactive components for cancer treatment: A recent review. Int J Biol Macromol 2023; 253:126623. [PMID: 37657573 DOI: 10.1016/j.ijbiomac.2023.126623] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 08/25/2023] [Accepted: 08/29/2023] [Indexed: 09/03/2023]
Abstract
The quest for safe chemotherapy has attracted researchers to explore anticancer potential of herbal medicines. Owing to upsurging evidence of herbal drug's beneficial effects, hopes are restored for augmenting survival rates in cancer patients. However, phytoconstituents confronted severe limitations in terms of poor absorption, low-stability, and low bioavailability. Along with toxicity issues associated with phytoconstituents, quality control and limited regulatory guidance also hinder the prevalence of herbal medicines for cancer therapy. Attempts are underway to exploit nanocarriers to circumvent the limitations of existing and new herbal drugs, where biological macromolecules (e.g., chitosan, hyaluronic acid, etc.) are established highly effective in fabricating nanocarriers and cancer targeting. Among the discussed nanocarriers, liposomes and micelles possess properties to cargo hydro- and lipophilic herbal constituents with surface modification for targeted delivery. Majorly, PEG, transferrin and folate are utilized for surface modification to improve bioavailability, circulation time and targetability. The dendrimer and carbon nanotubes responded in high-loading efficiency of phytoconstituent; whereas, SLN and nanoemulsions are suited carriers for lipophilic extracts. This review emphasized unveiling the latent potential of herbal drugs along with discussing on extended benefits of nanocarriers-based delivery of phytoconstituents for safe cancer therapy owing to enhanced clinical and preclinical outcomes without compromising safety.
Collapse
Affiliation(s)
- Bapi Gorain
- Department of Pharmaceutical Sciences and Technology, Birla Institute of Technology, Mesra, Ranchi 835215, India.
| | - Varnita Karmakar
- Department of Pharmaceutical Sciences and Technology, Birla Institute of Technology, Mesra, Ranchi 835215, India
| | - Biswatrish Sarkar
- Department of Pharmaceutical Sciences and Technology, Birla Institute of Technology, Mesra, Ranchi 835215, India
| | - Monika Dwivedi
- Department of Pharmaceutical Sciences and Technology, Birla Institute of Technology, Mesra, Ranchi 835215, India
| | - Janelle Tsui Lyn Leong
- School of Pharmacy, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya 47500, Selangor, Malaysia
| | - Jing Hen Toh
- School of Pharmacy, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya 47500, Selangor, Malaysia
| | - Even Seah
- School of Pharmacy, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya 47500, Selangor, Malaysia
| | - Kang Yi Ling
- School of Pharmacy, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya 47500, Selangor, Malaysia
| | - Kah Yee Chen
- School of Pharmacy, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya 47500, Selangor, Malaysia
| | - Hira Choudhury
- Department of Pharmaceutical Technology, School of Pharmacy, International Medical University, Bukit Jalil, 57000 Kuala Lumpur, Malaysia
| | - Manisha Pandey
- Department of Pharmaceutical Sciences, Central University of Haryana, SSH 17, Jant, Haryana 123031, India.
| |
Collapse
|
8
|
Srinivas S, Senthil Kumar SM, Senthil Kumar A. Edge and Basal Plane Anisotropy of a Preanodized Pencil Graphite Electrode Surface Revealed Using Scanning Electrochemical Microscopy and Electrocatalytic Dopamine Oxidation as a Molecular Probe. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:12563-12575. [PMID: 37646227 DOI: 10.1021/acs.langmuir.3c01112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Pencil graphite (PGE), an ultralow-cost and ready-to-use disposable-type electrode, has been used for various electrochemical and electroanalytical applications after its surface anodization (PGE*, * means preanodized surface). Indeed, systematic studies on mechanistic and surface features of PGE* have not yet been explored. Herein, we report anodized pencil graphite as a model system to study molecular level insights into the surface using a scanning electrochemical microscopy (SECM) technique and dopamine (DA) electrocatalytic oxidation reaction as a molecular probe. The as-prepared PGE* showed an appreciable electronic conductivity similar to the edge-plane graphitic sites (EPPG) of the highly pyrolytic graphitic electrode (HOPG) but without any surface deterioration that occurs with HOPG due to the instability of the EPPG. Physicochemical characterizations by FESEM, FTIR, Raman, and XPS techniques revealed a flake-like exfoliated PGE* surface with higher contents of carbon-oxygen especially phenolic/alcoholic functional groups than the PGE surface. Based on the chronocoulometric experiment, the number of functional groups formed on the PGE* was calculated as 10.9 × 10-10 mol cm-2. An independent SECM technique using ferricyanide as a redox probe showed the existence of a heterogeneous surface and exhibited an improved electron transfer activity due to the flake-like graphitic island on the PGE* surface. Investigated DA electrochemical oxidation on PGE* yielded about three times enhancement in the peak current signal and about 200 mV reduction in the oxidation potential over the PGE without any serious surface fouling feature that is related to the intermediate polydopamine formation on the basal-plane graphitic surface of the underlying electrode. As an independent electroanalytical study, a prototype electrochemical sensor using PGE* as a working electrode for instant detection of DA-containing pharmaceutical samples in a 1 mL Eppendorf vial has been demonstrated.
Collapse
Affiliation(s)
- Sakthivel Srinivas
- Nano and Bioelectrochemistry Research Laboratory, Carbon Dioxide Research and Green Technology Centre, Vellore Institute of Technology, Vellore 632 014, India
| | - Sakkarapalayam Murugesan Senthil Kumar
- Electroorganic and Materials Electrochemistry Division, CSIR-Central Electrochemical Research Institute, Karaikudi, Tamil Nadu 630 003, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201 002, India
| | - Annamalai Senthil Kumar
- Nano and Bioelectrochemistry Research Laboratory, Carbon Dioxide Research and Green Technology Centre, Vellore Institute of Technology, Vellore 632 014, India
- Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore632 014, India
| |
Collapse
|
9
|
Venegas CJ, Bollo S, Sierra-Rosales P. Carbon-Based Electrochemical (Bio)sensors for the Detection of Carbendazim: A Review. MICROMACHINES 2023; 14:1752. [PMID: 37763915 PMCID: PMC10536525 DOI: 10.3390/mi14091752] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 08/31/2023] [Accepted: 09/01/2023] [Indexed: 09/29/2023]
Abstract
Carbendazim, a fungicide widely used in agriculture, has been classified as a hazardous chemical by the World Health Organization due to its environmental persistence. It is prohibited in several countries; therefore, detecting it in food and environmental samples is highly necessary. A reliable, rapid, and low-cost method uses electrochemical sensors and biosensors, especially those modified with carbon-based materials with good analytical performance. In this review, we summarize the use of carbon-based electrochemical (bio)sensors for detecting carbendazim in environmental and food matrixes, with a particular interest in the role of carbon materials. Focus on publications between 2018 and 2023 that have been describing the use of carbon nanotubes, carbon nitride, graphene, and its derivatives, and carbon-based materials as modifiers, emphasizing the analytical performance obtained, such as linear range, detection limit, selectivity, and the matrix where the detection was applied.
Collapse
Affiliation(s)
- Constanza J. Venegas
- Programa Institucional de Fomento a la Investigación, Desarrollo e Innovación, Universidad Tecnológica Metropolitana, Ignacio Valdivieso 2409, San Joaquín, Santiago 8940577, Chile
| | - Soledad Bollo
- Centro de Investigación de Procesos Redox (CiPRex), Universidad de Chile, Sergio Livingstone Polhammer 1007, Independencia, Santiago 8380492, Chile
- Advanced Center for Chronic Diseases (ACCDiS), Universidad de Chile, Sergio Livingstone Polhammer 1007, Independencia, Santiago 8380492, Chile
| | - Paulina Sierra-Rosales
- Programa Institucional de Fomento a la Investigación, Desarrollo e Innovación, Universidad Tecnológica Metropolitana, Ignacio Valdivieso 2409, San Joaquín, Santiago 8940577, Chile
| |
Collapse
|
10
|
Gber TE, Louis H, Ngana OC, Amodu IO, Ekereke EE, Benjamin I, Adalikwu SA, Adeyinka A. Yttrium- and zirconium-decorated Mg 12O 12-X (X = Y, Zr) nanoclusters as sensors for diazomethane (CH 2N 2) gas. RSC Adv 2023; 13:25391-25407. [PMID: 37636506 PMCID: PMC10448449 DOI: 10.1039/d3ra02939e] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 07/21/2023] [Indexed: 08/29/2023] Open
Abstract
Diazomethane (CH2N2) presents a notable hazard as a respiratory irritant, resulting in various adverse effects upon exposure. Consequently, there has been increasing concern in the field of environmental research to develop a sensor material that exhibits heightened sensitivity and conductivity for the detection and adsorption of this gas. Therefore, this study aims to provide a comprehensive analysis of the geometric structure of three systems: CH2N2@MgO (C1), CH2N2@YMgO (CY1), and CH2N2@ZrMgO (CZ1), in addition to pristine MgO nanocages. The investigation involves a theoretical analysis employing the DFT/ωB97XD method at the GenECP/6-311++G(d,p)/SDD level of theory. Notably, the examination of bond lengths within the MgO cage yielded specific values, including Mg15-O4 (1.896 Å), Mg19-O4 (1.952 Å), and Mg23-O4 (1.952 Å), thereby offering valuable insights into the structural properties and interactions with CH2N2 gas. Intriguingly, after the interaction, bond length variations were observed, with CH2N2@MgO exhibiting shorter bonds and CH2N2@YMgO showcasing longer bonds. Meanwhile, CH2N2@ZrMgO displayed shorter bonds, except for a longer bond in Mg19-O4, suggesting increased stability due to shorter bond distances. The study further investigated the electronic properties, revealing changes in the energy gap that influenced electrical conductivity and sensitivity. The energy gap increased for Zr@MgO, CH2N2@MgO, CH2N2@YMgO, and CH2N2@ZrMgO, indicating weak interactions on the MgO surface. Conversely, Y@MgO showed a decrease in energy, suggesting a strong interaction. The pure MgO surface exhibited the ability to donate and accept electrons, resulting in an energy gap of 4.799 eV. Surfaces decorated with yttrium and zirconium exhibited decreased energies of the highest occupied molecular orbital (HOMO) and lowest unoccupied molecular orbital (LUMO), as well as decreased energy gap, indicating increased conductivity and sensitivity. Notably, Zr@MgO had the highest energy gap before CH2N2 adsorption, but C1 exhibited a significantly higher energy gap after adsorption, implying increased conductivity and sensitivity. The study also examined the density of states, demonstrating significant variations in the electronic properties of MgO and its decorated surfaces due to CH2N2 adsorption. Moreover, various analysis techniques were employed, including natural bond orbital (NBO), quantum theory of atoms in molecules (QTAIM), and noncovalent interaction (NCI) analysis, which provided insights into bonding, charge density, and intermolecular interactions. The findings contribute to a deeper understanding of the sensing mechanisms of CH2N2 gas on nanocage surfaces, shedding light on adsorption energy, conductivity, and recovery time. These results hold significance for gas-sensing applications and provide a basis for further exploration and development in this field.
Collapse
Affiliation(s)
- Terkumbur E Gber
- Computational and Bio-Simulation Research Group, University of Calabar Calabar Nigeria
- Department of Pure and Applied Chemistry, Faculty of Physical Sciences, University of Calabar Calabar Nigeria
| | - Hitler Louis
- Computational and Bio-Simulation Research Group, University of Calabar Calabar Nigeria
- Department of Pure and Applied Chemistry, Faculty of Physical Sciences, University of Calabar Calabar Nigeria
- Centre for Herbal Pharmacology and Environmental Sustainability, Chettinad Hospital and Research Institute, Chettinad Academy of Research and Education Kelambakkam-603103 Tamil Nadu India
| | - Obinna C Ngana
- Department of Chemical Sciences, Federal University of Wukari Wukari Taraba State Nigeria
| | - Ismail O Amodu
- Computational and Bio-Simulation Research Group, University of Calabar Calabar Nigeria
- Department of Mathematics, Faculty of Physical Sciences, University of Calabar Calabar Nigeria
| | - Ernest E Ekereke
- Computational and Bio-Simulation Research Group, University of Calabar Calabar Nigeria
- Department of Mathematics, Faculty of Physical Sciences, University of Calabar Calabar Nigeria
| | - Innocent Benjamin
- Computational and Bio-Simulation Research Group, University of Calabar Calabar Nigeria
| | - Stephen A Adalikwu
- Computational and Bio-Simulation Research Group, University of Calabar Calabar Nigeria
| | - Adedapo Adeyinka
- Department of Chemical Sciences, University of Johannesburg South Africa
| |
Collapse
|
11
|
Tsong JL, Robert R, Khor SM. Emerging trends in wearable glove-based sensors: A review. Anal Chim Acta 2023; 1262:341277. [PMID: 37179058 DOI: 10.1016/j.aca.2023.341277] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 04/22/2023] [Accepted: 04/24/2023] [Indexed: 05/15/2023]
Abstract
Glove-based wearable chemical sensors are universal analytical tools that provide surface analysis for various samples in dry or liquid form by swiping glove sensors on the sample surface. They are useful in crime scene investigation, airport security, and disease control for detecting illicit drugs, hazardous chemicals, flammables, and pathogens on various surfaces, such as foods and furniture. It overcomes the inability of most portable sensors to monitor solid samples. It outperforms most wearable sensors (e.g., contact lenses and mouthguard sensors) for healthcare monitoring by providing comfort that does not interfere with daily activities and reducing the risk of infection or other adverse health effects caused by prolonged usage. Detailed information is provided regarding the challenges and selection criteria for the desired glove materials and conducting nanomaterials for developing glove-based wearable sensors. Focusing on nanomaterials, various transducer modification techniques for various real-world applications are discussed. The steps taken by each study platform to address the existing issues are revealed, as are their benefits and drawbacks. The Sustainable Development Goals (SDGs) and strategies for properly disposing of used glove-based wearable sensors are critically evaluated. A glance at all the provided tables provides insight into the features of each glove-based wearable sensor and enables a quick comparison of their functionalities.
Collapse
Affiliation(s)
- Jia Ling Tsong
- Department of Chemistry, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Rodney Robert
- Department of Chemistry, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Sook Mei Khor
- Department of Chemistry, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia; Centre for Fundamental and Frontier Sciences in Nanostructure Self-Assembly, Department of Chemistry, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia; Centre for Innovation in Medical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia.
| |
Collapse
|
12
|
Senthil Kumar P, G P, Elavarasan N, Sreeja BS. A selective analysis of sulfamethoxazole - Trimethoprim in tablet formulations using graphene oxide-zinc oxide quantum dots based nanocomposite modified glassy carbon electrode. CHEMOSPHERE 2023; 332:138814. [PMID: 37149102 DOI: 10.1016/j.chemosphere.2023.138814] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 03/18/2023] [Accepted: 04/28/2023] [Indexed: 05/08/2023]
Abstract
In this study, simultaneous analysis on electrochemical detection of SMX and TMP in tablet formulation has been made using graphene oxide (GO) and ZnO QDs (GO-ZnO QDs) based nanocomposite modified glassy carbon electrode (GCE). The functional group presence was observed using FTIR study. The electrochemical characterization for GO, ZnO QDs and GO-ZnO QDs was studied using cyclic voltammetry using [Fe(CN)6]3- medium. In order to estimate the electrochemical redox behavior of SMX and TMP from tablet, the developed electrodes GO/GCE, ZnO QDs/GCE and GO-ZnO QDs/GCE are initially tested for electrochemical activity towards the SMX tablet in BR pH 7 medium. Later their electrochemical sensing has been monitored using square wave voltammetry (SWV). On observing the characteristic behavior of developed electrodes, GO/GCE exhibited detection potential of +0.48 V for SMX and +1.37 V for TMP whereas, ZnO QDs/GCE with +0.78V for SMX and for TMP 1.01 V respectively. Similarly, for GO-ZnO QDs/GCE, its 0.45 V for SMX and 1.11 V for TMP are observed using cyclic voltammetry. The obtained potential results on detecting SMX and TMP are in good agreement with previous results. Under optimized conditions, the response has been monitored with linear concentration range 50 μg/L to 300 μg/L for GO/GCE, ZnO QDs/GCE and GO-ZnO QDs/GCE in SMX tablet formulations. Their detection limits for the individual detection using GO-ZnO/GCE for SMX and TMP are found to be 0.252 ng/L and 19.10 μg/L and for GO/GCE it was 0.252 pg/L and 2.059 ng/L respectively. It was observed that ZnO QDs/GCE could not provide the electrochemical sensing towards SMX and TMP which may be due to the ZnO QPs can act as a blocking layer impeding the electron transfer process. Thus, the sensor performance lead to promising biomedical applications in real-time monitoring on evaluating selective analysis with SMX and TMP in tablet formulations.
Collapse
Affiliation(s)
- P Senthil Kumar
- Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603110, Tamil Nadu, India; Centre of Excellence in Water Research (CEWAR), Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India.
| | - Padmalaya G
- Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603110, Tamil Nadu, India; Centre of Excellence in Water Research (CEWAR), Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India
| | - N Elavarasan
- Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603110, Tamil Nadu, India; Centre of Excellence in Water Research (CEWAR), Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India
| | - B S Sreeja
- Centre of Excellence in Water Research (CEWAR), Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603 110, Tamil Nadu, India; Department of Electronics and Communication Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, 603110, Tamil Nadu, India
| |
Collapse
|
13
|
Abd El-Mageed AIA, Ogawa T. Identification of Supramolecular Structures of Porphyrin Polymer on Single-Walled Carbon Nanotube Surface Using Microscopic Imaging Techniques. Polymers (Basel) 2023; 15:1439. [PMID: 36987219 PMCID: PMC10051620 DOI: 10.3390/polym15061439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 12/28/2022] [Accepted: 01/02/2023] [Indexed: 03/16/2023] Open
Abstract
Although the supramolecular structure of porphyrin polymers on flat surfaces (i.e., mica and HOPG) has been extensively studied, the self-assembly arrays of porphyrin polymers on the SWNT (as curved nanocarbon surfaces) have yet to be fully identified and/or investigated, especially using microscopic imaging techniques, i.e., scanning tunneling microscopy (STM), atomic force microscopy (AFM), and transmission electron microscopy (TEM). This study reports the identification of the supramolecular structure of poly-[5,15-bis-(3,5-isopentoxyphenyl)-10,20-bis ethynylporphyrinato]-zinc (II) on the SWNT surface using mainly AFM and HR-TEM microscopic imaging techniques. After synthesizing around >900 mer of porphyrin polymer (via Glaser-Hay coupling); the as-prepared porphyrin polymer is then non-covalently adsorbed on SWNT surface. Afterward, the resultant porphyrin/SWNT nanocomposite is then anchored with gold nanoparticles (AuNPs), which are used as a marker, via coordination bonding to produce a porphyrin polymer/AuNPs/SWNT hybrid. The polymer, AuNPs, nanocomposite, and/or nanohybrid are characterized using 1H-NMR, mass spectrometry, UV-visible spectroscopy, AFM, as well as HR-TEM measuring techniques. The self-assembly arrays of porphyrin polymers moieties (marked with AuNPs) prefer to form a coplanar well-ordered, regular, repeated array (rather than wrapping) between neighboring molecules along the polymer chain on the tube surface. This will help with further understanding, designing, and fabricating novel supramolecular architectonics of porphyrin/SWNT-based devices.
Collapse
Affiliation(s)
- Ahmed I. A. Abd El-Mageed
- Chemistry Department, Faculty of Science, GALALA University, Galala City 43711, Egypt
- Colloids & Advanced Materials Group, Chemistry Department, Faculty of Science, Minia University, Minia 61519, Egypt
| | - Takuji Ogawa
- Chemistry Department, Graduate School of Science, Osaka University, Machikaneyama 1-1, Toyonaka 560-0043, Osaka, Japan
| |
Collapse
|
14
|
Zha X, Yang W, Shi L, Zeng Q, Xu J, Yang Y. 2D bimetallic organic framework nanosheets for high-performance wearable power source and real-time monitoring of glucose. Dalton Trans 2023; 52:2631-2640. [PMID: 36744545 DOI: 10.1039/d2dt03311a] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Diabetics often prick their fingertips to measure the glucose levels in their blood. However, this traditional method not only causes prolonged pain but also increases the risk of infection. Hence, in this study, a non-invasive flexible glucose biosensor with high sensitivity was fabricated. Specifically, NiCo metal-organic frameworks (NiCo-MOFs) served as the electrode material of a micro-supercapacitor and sensing material of a glucose sensor. The electrochemical tests verified that the prominent sensitivity of the NiCo bimetal product is 1422.2 μA mM-1 cm-2. The micro-supercapacitor based on the as-fabricated NiCo-MOFs showed a high energy density of 11.5 mW h cm-2 at the power density 0.26 mW cm-2. In addition, the as-designed glucose device exhibited an excellent sensitivity of 0.31 μA μM-1. Furthermore, a flexible energy storage and glucose detection system was successfully prepared by further integrating the micro-supercapacitor and glucose sensor. The smart detector could accurately and conveniently measure the glucose concentration in sweat in real-time. Therefore, the wearable real-time sensing device displays feasible application for non-invasive glucose monitoring and health management.
Collapse
Affiliation(s)
- Xiaoting Zha
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China.
| | - Wenyao Yang
- Chongqing Engineering Research Center of New Energy Storage Devices and Applications, Chongqing University of Arts and Sciences, Chongqing, 402160, China.
| | - Liuwei Shi
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China.
| | - Qi Zeng
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China.
| | - Jianhua Xu
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China.
| | - Yajie Yang
- School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China. .,Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou, 313001, China
| |
Collapse
|
15
|
Li Z, Xiao M, Jin C, Zhang Z. Toward the Commercialization of Carbon Nanotube Field Effect Transistor Biosensors. BIOSENSORS 2023; 13:326. [PMID: 36979538 PMCID: PMC10046102 DOI: 10.3390/bios13030326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Revised: 02/21/2023] [Accepted: 02/24/2023] [Indexed: 06/18/2023]
Abstract
The development of biosensors based on field-effect transistors (FETs) using atomically thick carbon nanotubes (CNTs) as a channel material has the potential to revolutionize the related field due to their small size, high sensitivity, label-free detection, and real-time monitoring capabilities. Despite extensive research efforts to improve the sensitivity, selectivity, and practicality of CNT FET-based biosensors, their commercialization has not yet been achieved due to the non-uniform and unstable device performance, difficulties in their fabrication, the immaturity of sensor packaging processes, and a lack of reliable modification methods. This review article focuses on the practical applications of CNT-based FET biosensors for the detection of ultra-low concentrations of biologically relevant molecules. We discuss the various factors that affect the sensors' performance in terms of materials, device architecture, and sensor packaging, highlighting the need for a robust commercial process that prioritizes product performance. Additionally, we review recent advances in the application of CNT FET biosensors for the ultra-sensitive detection of various biomarkers. Finally, we examine the key obstacles that currently hinder the large-scale deployment of these biosensors, aiming to identify the challenges that must be addressed for the future industrialization of CNT FET sensors.
Collapse
Affiliation(s)
- Zhongyu Li
- Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan 411105, China
- Key Laboratory for the Physics and Chemistry of Nanodevices and Center for Carbon-Based Electronics, School of Electronics, Peking University, Beijing 100871, China
- Jihua Laboratory, Foshan 528200, China
| | - Mengmeng Xiao
- Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan 411105, China
- Key Laboratory for the Physics and Chemistry of Nanodevices and Center for Carbon-Based Electronics, School of Electronics, Peking University, Beijing 100871, China
| | - Chuanhong Jin
- Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan 411105, China
- Jihua Laboratory, Foshan 528200, China
- State Key Laboratory of Silicon Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou 310027, China
| | - Zhiyong Zhang
- Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan 411105, China
- Key Laboratory for the Physics and Chemistry of Nanodevices and Center for Carbon-Based Electronics, School of Electronics, Peking University, Beijing 100871, China
- Jihua Laboratory, Foshan 528200, China
| |
Collapse
|
16
|
Fan J, Shang T, Duan P. Design of electrochemical sensor for 1,3-propanediol detection in presence of glycerol. INT J ELECTROCHEM SC 2023. [DOI: 10.1016/j.ijoes.2023.100031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
|
17
|
Li Z, Wang Y, Fan Z, Sun Y, Sun Y, Yang Y, Zhang Y, Ma J, Wang Z, Zhu Z. A Dual-Function Wearable Electrochemical Sensor for Uric Acid and Glucose Sensing in Sweat. BIOSENSORS 2023; 13:bios13010105. [PMID: 36671938 PMCID: PMC9855683 DOI: 10.3390/bios13010105] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/30/2022] [Accepted: 01/04/2023] [Indexed: 05/27/2023]
Abstract
Simultaneous detection of uric acid and glucose using a non-invasive approach can be a promising strategy for related diseases, e.g., diabetes, gout, kidney disease, and cardiovascular disease. In this study, we have proposed a dual-function wearable electrochemical sensor for uric acid and glucose detection in sweat. The sensor with a four-electrode system was prepared by printing the ink on a common rubber glove. CV and chronoamperometry were used to characterize the prepared sensor's electrochemical sensing performance. The sensors exhibited the linear range from 0 to 1.6 mM and 0 to 3.7 mM towards uric acid and glucose electrochemical sensing in phosphate-buffered solution, with the corresponding limit of detection of 3.58 μM and 9.10 μM obtained, respectively. Moreover, the sensors had shown their feasibility of real sample sensing in sweat. The linear detection range for uric acid (0 to 40 μM) and glucose (0 to 1.6 mM) in the sweat can well cover their concentration range in physiological conditions. The prepared dual-function wearable electrochemical sensor features easy preparation, fast detection, high sensitivity, high selectivity, and the practical application potential in uric acid and glucose sensing.
Collapse
|
18
|
Jose J, Prakash P, Jeyaprabha B, Abraham R, Mathew RM, Zacharia ES, Thomas V, Thomas J. Principle, design, strategies, and future perspectives of heavy metal ion detection using carbon nanomaterial-based electrochemical sensors: a review. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2023. [DOI: 10.1007/s13738-022-02730-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
19
|
Vieira D, Allard J, Taylor K, Harvey EJ, Merle G. Zincon-Modified CNTs Electrochemical Tool for Salivary and Urinary Zinc Detection. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:4431. [PMID: 36558285 PMCID: PMC9784302 DOI: 10.3390/nano12244431] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 12/07/2022] [Accepted: 12/08/2022] [Indexed: 06/17/2023]
Abstract
Recently, the abnormal level of zinc emerged as a powerful indicator or risk factor for metabolic, endocrine, neurodegenerative and cardiovascular diseases, including cancer. Electrochemical detection has been explored to quantify zinc in a precise, rapid, and non-expensive way; however, most of the current electrochemical systems lack in specificity. In this work we studied a highly selective and sensitive electrochemical method to detect quickly and reliably free zinc ions (Zn2+). The surface of the working electrode was modified with zincon electropolymerized on carbon nanotube (CNT) to enable the binding of zinc in complex body fluids. After being physicochemically characterized, the performances of the zincon-CNT complex was electrochemically assessed. Square Wave Voltammetry (SWV) was used to determine the calibration curve and the linear range of zinc quantification in artificial saliva and urine. This zincon- CNT system could specifically quantify mobile Zn2+ in salivary and urinary matrices with a sensitivity of ~100 ng·mL-1 and a limit of detection (LOD) of ~20 ng·mL-1. Zincon-modified CNT presented as a desirable candidate for the detection and quantification of free zinc in easily body fluids that potentially can become a diagnostic non-invasive testing platform.
Collapse
Affiliation(s)
- Daniela Vieira
- Department of Experimental Surgery, Faculty of Medicine, McGill University, 1650 Cedar Avenue, A7-117, Montreal, QC H3G 1A4, Canada
| | - Jérôme Allard
- Department of Chemical Engineering, Polytechnique Montreal, J.-A.-Bombardier Building, Office 2067, Montreal, QC H3C 3A7, Canada
| | - Kathleen Taylor
- Department of Chemical Engineering, Polytechnique Montreal, J.-A.-Bombardier Building, Office 2067, Montreal, QC H3C 3A7, Canada
- Department of Chemical and Biomolecular Engineering, Georgia Institute of Technology, 311 Ferst Dr, Atlanta, GA 30318, USA
| | - Edward J. Harvey
- Department of Experimental Surgery, Faculty of Medicine, McGill University, 1650 Cedar Avenue, A7-117, Montreal, QC H3G 1A4, Canada
| | - Geraldine Merle
- Department of Experimental Surgery, Faculty of Medicine, McGill University, 1650 Cedar Avenue, A7-117, Montreal, QC H3G 1A4, Canada
- Department of Chemical Engineering, Polytechnique Montreal, J.-A.-Bombardier Building, Office 2067, Montreal, QC H3C 3A7, Canada
| |
Collapse
|
20
|
Xiao J, Shi S, Yao L, Feng J, Zuo J, He Q. Fast and Ultrasensitive Electrochemical Detection for Antiviral Drug Tenofovir Disoproxil Fumarate in Biological Matrices. BIOSENSORS 2022; 12:1123. [PMID: 36551090 PMCID: PMC9775179 DOI: 10.3390/bios12121123] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 11/23/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
Tenofovir disoproxil fumarate (TDF) is an antiretroviral medication with significant curative effects, so its quantitative detection is important for human health. At present, there are few studies on the detection of TDF by electrochemical sensors. This work can be a supplement to the electrochemical detection of TDF. Moreover, bare electrodes are susceptible to pollution, and have high overvoltage and low sensitivity, so it is crucial to find a suitable electrode material. In this work, zirconium oxide (ZrO2) that has a certain selectivity to phosphoric acid groups was synthesized by a hydrothermal method with zirconyl chloride octahydrate as the precursor. A composite modified glassy carbon electrode for zirconium oxide-chitosan-multiwalled carbon nanotubes (ZrO2-CS-MWCNTs/GCE) was used for the first time to detect the TDF, and achieved rapid, sensitive detection of TDF with a detection limit of sub-micron content. The ZrO2-CS-MWCNTs composite was created using sonication of a mixture of ZrO2 and CS-MWCNTs solution. The composite was characterized using scanning electron microscopy (SEM) and cyclic voltammetry (CV). Electrochemical analysis was performed using differential pulse voltammetry (DPV). Compared with single-material electrodes, the ZrO2-CS-MWCNTs/GCE significantly improves the electrochemical sensing of TDF due to the synergistic effect of the composite. Under optimal conditions, the proposed method has achieved good results in linear range (0.3~30 μM; 30~100 μM) and detection limit (0.0625 μM). Moreover, the sensor has the merits of simple preparation, good reproducibility and good repeatability. The ZrO2-CS-MWCNTs/GCE has been applied to the determination of TDF in serum and urine, and it may be helpful for potential applications of other substances with similar structures.
Collapse
Affiliation(s)
- Jingyun Xiao
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
- Hunan Qianjin Xiangjiang Pharmaceutical Joint Stock Co., Ltd., Zhuzhou 412001, China
- Geriatric Rehabilitation Department, Zhuzhou People’s Hospital, Zhuzhou 421007, China
| | - Shuting Shi
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
| | - Liangyuan Yao
- Hunan Qianjin Xiangjiang Pharmaceutical Joint Stock Co., Ltd., Zhuzhou 412001, China
| | - Jinxia Feng
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
| | - Jinsong Zuo
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
| | - Quanguo He
- School of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, China
- Hunan Qianjin Xiangjiang Pharmaceutical Joint Stock Co., Ltd., Zhuzhou 412001, China
- Geriatric Rehabilitation Department, Zhuzhou People’s Hospital, Zhuzhou 421007, China
| |
Collapse
|
21
|
Vieira D, Barralet J, Harvey EJ, Merle G. Detecting the PEX Like Domain of Matrix Metalloproteinase-14 (MMP-14) with Therapeutic Conjugated CNTs. BIOSENSORS 2022; 12:884. [PMID: 36291022 PMCID: PMC9599479 DOI: 10.3390/bios12100884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 10/05/2022] [Accepted: 10/13/2022] [Indexed: 06/16/2023]
Abstract
Matrix metalloproteinases (MMPs) are essential proteins acting directly in the breakdown of the extra cellular matrix and so in cancer invasion and metastasis. Given its impact on tumor angiogenesis, monitoring MMP-14 provides strategic insights on cancer severity and treatment. In this work, we report a new approach to improve the electrochemical interaction of the MMP-14 with the electrode surface while preserving high specificity. This is based on the detection of the hemopexin (PEX) domain of MMP-14, which has a greater availability with a stable and low-cost commercial molecule, as a recognition element. This molecule, called NSC-405020, is specific of the PEX domain of MMP-14 within the binding pocket. Through the covalent grafting of the NSC-405020 molecule on carbon nanotubes (CNTs), we were able to detect and quantify MMP-14 using electrochemical impedance spectroscopy with a linear range of detection of 10 ng⋅mL-1 to 100 ng⋅mL-1, and LOD of 7.5 ng⋅mL-1. The specificity of the inhibitory small molecule was validated against the PEX domain of MMP-1. The inhibitor loaded CNTs system showed as a desirable candidate to become an alternative to the conventional recognition bioelements for the detection of MMP-14.
Collapse
Affiliation(s)
- D. Vieira
- Department of Experimental Surgery, Faculty of Medicine, McGill University, Montreal, QC H3G 2M1, Canada; (D.V.); (J.B.); (E.J.H.)
| | - J. Barralet
- Department of Experimental Surgery, Faculty of Medicine, McGill University, Montreal, QC H3G 2M1, Canada; (D.V.); (J.B.); (E.J.H.)
- Department of Surgery, McGill University, Montreal, QC H3G 1A4, Canada
| | - E. J. Harvey
- Department of Experimental Surgery, Faculty of Medicine, McGill University, Montreal, QC H3G 2M1, Canada; (D.V.); (J.B.); (E.J.H.)
- Department of Surgery, McGill University, Montreal, QC H3G 1A4, Canada
| | - G. Merle
- Department of Experimental Surgery, Faculty of Medicine, McGill University, Montreal, QC H3G 2M1, Canada; (D.V.); (J.B.); (E.J.H.)
- Department of Chemical Engineering, Polytechnique Montreal, Montreal, QC H3T 1J4, Canada
| |
Collapse
|
22
|
Ramachandran B, Liao YC. Microfluidic wearable electrochemical sweat sensors for health monitoring. BIOMICROFLUIDICS 2022; 16:051501. [PMID: 36186757 PMCID: PMC9520469 DOI: 10.1063/5.0116648] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Accepted: 08/31/2022] [Indexed: 06/16/2023]
Abstract
Research on remote health monitoring through wearable sensors has attained popularity in recent decades mainly due to aging population and expensive health care services. Microfluidic wearable sweat sensors provide economical, non-invasive mode of sample collection, important physiological information, and continuous tracking of human health. Recent advances in wearable sensors focus on electrochemical monitoring of biomarkers in sweat and can be applicable in various fields like fitness monitoring, nutrition, and medical diagnosis. This review focuses on the evolution of wearable devices from benchtop electrochemical systems to microfluidic-based wearable sensors. Major classification of wearable sensors like skin contact-based and biofluidic-based sensors are discussed. Furthermore, sweat chemistry and related biomarkers are explained in addition to integration of microfluidic systems in wearable sweat sensors. At last, recent advances in wearable electrochemical sweat sensors are discussed, which includes tattoo-based, paper microfluidics, patches, wrist band, and belt-based wearable sensors.
Collapse
Affiliation(s)
- Balaji Ramachandran
- Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Ying-Chih Liao
- Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan
| |
Collapse
|
23
|
Aihaiti A, Li Z, Qin Y, Meng F, Li X, Huangfu Z, Chen K, Zhang M. Construction of Electrochemical Sensors for Antibiotic Detection Based on Carbon Nanocomposites. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:2789. [PMID: 36014654 PMCID: PMC9414981 DOI: 10.3390/nano12162789] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 07/22/2022] [Accepted: 08/09/2022] [Indexed: 06/15/2023]
Abstract
Excessive antibiotic residues in food can cause detrimental effects on human health. The establishment of rapid, sensitive, selective, and reliable methods for the detection of antibiotics is highly in demand. With the inherent advantages of high sensitivity, rapid analysis time, and facile miniaturization, the electrochemical sensors have great potential in the detection of antibiotics. The electrochemical platforms comprising carbon nanomaterials (CNMs) have been proposed to detect antibiotic residues. Notably, with the introduction of functional CNMs, the performance of electrochemical sensors can be bolstered. This review first presents the significance of functional CNMs in the detection of antibiotics. Subsequently, we provide an overview of the applications for detection by enhancing the electrochemical behaviour of the antibiotic, as well as a brief overview of the application of recognition elements to detect antibiotics. Finally, the trend and the current challenges of electrochemical sensors based on CNMs in the detection of antibiotics is outlined.
Collapse
Affiliation(s)
- Aihemaitijiang Aihaiti
- College of Life Science & Technology, Xinjiang University, Urumqi 830017, China
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, Urumqi 830017, China
| | - Zongda Li
- College of Life Science & Technology, Xinjiang University, Urumqi 830017, China
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, Urumqi 830017, China
| | - Yanan Qin
- College of Life Science & Technology, Xinjiang University, Urumqi 830017, China
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, Urumqi 830017, China
| | - Fanxing Meng
- College of Life Science & Technology, Xinjiang University, Urumqi 830017, China
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, Urumqi 830017, China
| | - Xinbo Li
- College of Life Science & Technology, Xinjiang University, Urumqi 830017, China
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, Urumqi 830017, China
| | - Zekun Huangfu
- College of Life Science & Technology, Xinjiang University, Urumqi 830017, China
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, Urumqi 830017, China
| | - Keping Chen
- Xinjiang Huize Foodstuff Co., Ltd., Wujiaqu City 830073, China
| | - Minwei Zhang
- College of Life Science & Technology, Xinjiang University, Urumqi 830017, China
- Xinjiang Key Laboratory of Biological Resources and Genetic Engineering, Urumqi 830017, China
| |
Collapse
|
24
|
Aydın EB, Aydın M, Sezgintürk MK. Impedimetric Detection of Calreticulin by a Disposable Immunosensor Modified with a Single-Walled Carbon Nanotube-Conducting Polymer Nanocomposite. ACS Biomater Sci Eng 2022; 8:3773-3784. [PMID: 35920068 DOI: 10.1021/acsbiomaterials.2c00499] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A label-free impedimetric immunosensing system was constructed for ultrasensitive determination of the calreticulin (CALR) biological marker in human serum samples utilizing an electrochemical impedance spectroscopy analysis technique for the first time. The new biosensor fabrication procedure consisted of electrodeposition of single-walled carbon nanotubes (SWCNTs) incorporating polymerization of an oxiran-2-yl methyl 3-(1H-pyrrol-1-yl) propanoate monomer (Pepx) onto a low-cost and disposable indium tin oxide (ITO) electrode. The SWCNTs-PPepx nanocomposite layer was prepared onto the ITO after the one-step fabrication procedure. The fabrication procedure of the immunosensor and the characteristic biomolecular interactions between the anti-CALR and CALR were characterized by electrochemical analysis and morphological monitoring techniques. Under optimum conditions, the proposed biosensor was responsive to CALR concentrations over the detection ranges of 0.015-60 pg/mL linearly, and it had a very low detection limit (4.6 fg/mL) and a favorable sensitivity (0.43 kΩ pg-1 mL cm-2). The reliability of the biosensor system in clinical analysis was investigated by successful quantification of CALR levels in human serum. Moreover, the repeatability and reproducibility results of the biosensor were evaluated by using Dixon, Grubbs, T-test, and F-tests. Consequently, the proposed biosensor was a promising method for scientific, rapid, and successful analysis of CALR in human serum samples.
Collapse
Affiliation(s)
- Elif Burcu Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Campus Street, Tekirdağ 59030, Turkey
| | - Muhammet Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Campus Street, Tekirdağ 59030, Turkey
| | - Mustafa Kemal Sezgintürk
- Faculty of Engineering, Bioengineering Department, Çanakkale Onsekiz Mart University, Çanakkale 17100, Turkey
| |
Collapse
|
25
|
Shi M, Xue S, Xu J, Chen S, Zou J, Gao Y, Liu S, Duan X, Lu L. Amplified electrochemical determination of niclosamide in food based on carbon nanohorn@MWCNT composite. Anal Bioanal Chem 2022; 414:4119-4127. [PMID: 35449471 DOI: 10.1007/s00216-022-04060-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2022] [Revised: 03/11/2022] [Accepted: 04/04/2022] [Indexed: 11/25/2022]
Abstract
In this work, carbon nanohorn (CNH)-decorated multi-walled carbon nanotube (MWCNT) (CNH@MWCNT) composite was prepared and used to modify glass carbon electrode (GCE) as sensitive electrochemical sensor for niclosamide (NA) determination. Herein, the decoration of CNHs induces higher dispersibility for MWCNTs, and endows the composite with better conductivity, larger surface area, and higher catalytic activity, which leads to significantly enhanced electrochemical behavior toward NA oxidation. The parameters such as mass ratios of CNHs and MWCHTs, the amount of composite materials, the accumulation time, and the solution pH are systematically optimized. Under optimized conditions, the developed electrochemical sensor exhibits a low detection limit of 2.0 nM with a wide linear range of 7.0 nM-10.0 µM and high anti-interference ability. In addition, the sensor displays good stability, repeatability, and reproducibility. The feasibility of the assay was verified by testing NA in brown rice and rice field water samples.
Collapse
Affiliation(s)
- Min Shi
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, Engineering Center of Jiangxi University for Fine Chemicals, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, 330013, People's Republic of China
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang, 330045, People's Republic of China
| | - Shuya Xue
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, Engineering Center of Jiangxi University for Fine Chemicals, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, 330013, People's Republic of China
| | - Jingkun Xu
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, Engineering Center of Jiangxi University for Fine Chemicals, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, 330013, People's Republic of China
| | - Shuxian Chen
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, Engineering Center of Jiangxi University for Fine Chemicals, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, 330013, People's Republic of China
| | - Jin Zou
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang, 330045, People's Republic of China
| | - Yansha Gao
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang, 330045, People's Republic of China
| | - Shuwu Liu
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang, 330045, People's Republic of China
| | - Xuemin Duan
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, Engineering Center of Jiangxi University for Fine Chemicals, School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang, 330013, People's Republic of China.
| | - Limin Lu
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang, 330045, People's Republic of China.
| |
Collapse
|
26
|
Zhang T, Shen Y, Ge J, Wang W, Qu L, Li Z. A highly sensitive fluorescence method for the detection of T4 polynucleotide kinase phosphatase based on polydopamine nanotubes. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 267:120594. [PMID: 34776378 DOI: 10.1016/j.saa.2021.120594] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 10/19/2021] [Accepted: 11/03/2021] [Indexed: 06/13/2023]
Abstract
T4 polynucleotide kinase phosphatase (T4 PNKP) plays a critical role in various cellular events, such as DNA damage repair, replication, and recombination. Here, we have described a novel biosensor to detect the activity of T4 PNKP based on polydopamine nanotubes (PDANTs) mediated fluorescence resonance energy transfer (FRET). A FAM-labelled (6-carboxyl-fluorescein) hairpin DNA probe with 3'-phosphoryl terminal was designed as the substrate for T4 PNKP. With the addition of PDANTs, the fluorescence of FAM-labelled hairpin DNA probe could be quenched because of the high adsorption of hairpin DNA on PDANTs. When T4 PNKP dephosphorylated the DNA probe, a double-stranded DNA (dsDNA) product was obtained by Klenow fragment polymerase (KF polymerase) on its 3'-hydroxyl terminal, which could retain most of the fluorescence due to the week adsorption of dsDNA on PDANTs. The developed method demonstrates the sensitivity for T4 PNKP assay in the range from 0.05 to 1.5 U mL-1 with the detection limit of 0.005 U mL-1, which endows the proposed strategy with high enough sensitivity for practical detection in cell lysates. With the advantages mentioned above, this novel sensitive strategy has the potential in the study of DNA damage repair mechanisms.
Collapse
Affiliation(s)
- Tuo Zhang
- College of Chemistry, Green Catalysis Center, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou 450001, China
| | - Yanmei Shen
- College of Chemistry, Green Catalysis Center, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou 450001, China
| | - Jia Ge
- College of Chemistry, Green Catalysis Center, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou 450001, China.
| | - Weixia Wang
- College of Chemistry, Green Catalysis Center, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou 450001, China
| | - Lingbo Qu
- College of Chemistry, Green Catalysis Center, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou 450001, China.
| | - Zhaohui Li
- College of Chemistry, Green Catalysis Center, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou 450001, China
| |
Collapse
|
27
|
Huang J, Cheng W, Li Y. 3D carbonized wood-based integrated electrochemical immunosensor for ultrasensitive detection of procalcitonin antigen. Talanta 2022; 238:122991. [PMID: 34857324 DOI: 10.1016/j.talanta.2021.122991] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 10/18/2021] [Accepted: 10/20/2021] [Indexed: 11/28/2022]
Abstract
This work presents a novel 3D carbonized wood-based integrated electrochemical immunosensor for ultrasensitive detection of procalcitonin (PCT) antigen at picogram level, achieving a wide linear detection range for PCT concentrations range from 0.05 to 90 pg mL-1 with a low detection limit of 0.014 pg mL-1 (S/N = 3), outperforming the previous reports. 3D carbonized wood as a new immunosensor matrix is used for electrochemical PCT biosensing, improving the stability of electrode and overcoming the disadvantages of traditional glassy carbon electrode (GCE). It obtained an excellent detection result, due to it has abundant mutual crisscross microchannels that promote the reactants and electrons transfer, greatly amplify the current signal. This novel sandwich-type electrochemical immunosensor is composed of 3D carbonized wood, carboxylic multi-walled carbon nanotube (cMWCNT), Au@Co3O4 core-shell nanosphere and Au/single layer nitrogen-doped graphene (Au/SL-NG), when it is applied for PCT detection in real clinical samples, it exhibits high accuracy same as enzyme-linked immunosorbent assay (ELISA) method.
Collapse
Affiliation(s)
- Jianzhi Huang
- School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, Guangdong, 523808, People's Republic of China.
| | - Wenxue Cheng
- School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, Guangdong, 523808, People's Republic of China
| | - Yanliang Li
- School of Environment and Civil Engineering, Dongguan University of Technology, Dongguan, Guangdong, 523808, People's Republic of China.
| |
Collapse
|
28
|
Abd El-Mageed AIA, Ogawa T. Supramolecular Structures of Organic Molecules-Single Walled Carbon Nanotube Nanocomposites. ADVANCES IN NANOCOMPOSITE MATERIALS FOR ENVIRONMENTAL AND ENERGY HARVESTING APPLICATIONS 2022:921-940. [DOI: 10.1007/978-3-030-94319-6_29] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
29
|
Rahman MW, Mañas-Torres MC, Firouzeh S, Cuerva JM, Álvarez de Cienfuegos L, Pramanik S. Molecular Functionalization and Emergence of Long-Range Spin-Dependent Phenomena in Two-Dimensional Carbon Nanotube Networks. ACS NANO 2021; 15:20056-20066. [PMID: 34870421 DOI: 10.1021/acsnano.1c07739] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Molecular functionalization of CNTs is a routine procedure in the field of nanotechnology. However, whether and how these molecules affect the spin polarization of the charge carriers in CNTs are largely unknown. In this work we demonstrate that spin polarization can indeed be induced in two-dimensional (2D) CNT networks by "certain" molecules and the spin signal routinely survives length scales significantly exceeding 1 μm. This result effectively connects the area of molecular spintronics with that of carbon-based 2D nanoelectronics. By using the versatility of peptide chemistry, we further demonstrate how spin polarization depends on molecular structural features such as chirality as well as molecule-nanotube interactions. A chirality-independent effect was detected in addition to the more common chirality-dependent effect, and the overall spin signal was found to be a combination of both. Finally, the magnetic field dependence of the spin signals has been explored, and the "chirality-dependent" signal has been found to exist only in certain field angles.
Collapse
Affiliation(s)
- Md Wazedur Rahman
- Department of Electrical and Computer Engineering, University of Alberta, Alberta T6G 1H9, Canada
| | - Mari C Mañas-Torres
- Departamento de Química Orgánica, Facultad de Ciencias, Unidad de Excelencia de Química Aplicada a Biomedicina y Medioambiente (UEQ), Universidad de Granada, 18071 Granada, Spain
| | - Seyedamin Firouzeh
- Department of Electrical and Computer Engineering, University of Alberta, Alberta T6G 1H9, Canada
| | - Juan Manuel Cuerva
- Departamento de Química Orgánica, Facultad de Ciencias, Unidad de Excelencia de Química Aplicada a Biomedicina y Medioambiente (UEQ), Universidad de Granada, 18071 Granada, Spain
| | - Luis Álvarez de Cienfuegos
- Departamento de Química Orgánica, Facultad de Ciencias, Unidad de Excelencia de Química Aplicada a Biomedicina y Medioambiente (UEQ), Universidad de Granada, 18071 Granada, Spain
| | - Sandipan Pramanik
- Department of Electrical and Computer Engineering, University of Alberta, Alberta T6G 1H9, Canada
| |
Collapse
|
30
|
Yao J, Deng Y, Pan S, Korna R, Wen J, Yuan N, Wang K, Li H, Yang Y. The difference in the adsorption mechanisms of magnetic ferrites modified carbon nanotubes. JOURNAL OF HAZARDOUS MATERIALS 2021; 415:125551. [PMID: 33756199 DOI: 10.1016/j.jhazmat.2021.125551] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 02/25/2021] [Accepted: 02/25/2021] [Indexed: 05/27/2023]
Abstract
Various ferrites modified carbon nanotubes (MFe2O4/CNTs; M = Co, Cu, Mn) were synthesized and characterized using TEM-EDS, FTIR, BET, TG-DTA, VSM, and XRD. MFe2O4/CNTs were used as adsorbents for removing ciprofloxacin (CIP), and the adsorption mechanism was revealed in a comparative manner based on the experimental results and density functional theory calculations. The adsorption capacities of CIP on MFe2O4/CNTs were 63.32 (Co), 61.60 (Cu), and 46.35 (Mn) mg/g, respectively. Different M components of MFe2O4 affected the adsorption behavior of CIP on them, while the specific surface area and total pore volume showed no significant impact. The investigation on the adsorption energy and the bond formation indicated that CIP was more favorably captured by CoFe2O4/CuFe2O4 than MnFe2O4. The local density of states of metal atoms and O atoms (from the ketone or carboxyl groups of CIP) showed that the d-band centers of Co and Cu atoms were above the Fermi level, while that of Mn was below the Fermi level, providing the fundamental understanding of the promoted O adsorption on CoFe2O4 and CuFe2O4 and restrained adsorption on MnFe2O4. This observation was supported by the electron localization function in terms of the stronger charge density overlap between Co-O/Cu-O than that of Mn-O.
Collapse
Affiliation(s)
- Jingjing Yao
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China
| | - Yi Deng
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China
| | - Siyuan Pan
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China
| | - Ramon Korna
- School of Metallurgy and Environment, Central South University, Changsha 410083, PR China
| | - Jiayi Wen
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China
| | - Nadi Yuan
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China
| | - Kun Wang
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China
| | - Haipu Li
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China.
| | - Ying Yang
- Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China; Key Laboratory of Hunan Province for Water Environment and Agriculture Product Safety, Changsha 410083, PR China.
| |
Collapse
|
31
|
Kechit H, Belkhiri S, Bhakta AK, Trache D, Mekhalif Z, Tarchoun AF. The effect of iron decorated MWCNTs and iron‐ionic liquid decorated MWCNTs onto thermal decomposition of ammonium perchlorate. Z Anorg Allg Chem 2021. [DOI: 10.1002/zaac.202100153] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Hocine Kechit
- Laboratoire de Propulsion Energétique UER. Procédés Enegétiques Ecole Militaire Polytechnique (EMP) Chahid Abderrahmane Taleb BP 17 16046 Bordj El-Bahri Algiers Algeria
| | - Samir Belkhiri
- Laboratoire de Propulsion Energétique UER. Procédés Enegétiques Ecole Militaire Polytechnique (EMP) Chahid Abderrahmane Taleb BP 17 16046 Bordj El-Bahri Algiers Algeria
| | - Arvind Kumar Bhakta
- Laboratoire de Chimie et d'Electrochimie des Surfaces NISM Université de Namur 61 Rue de Bruxelles 5000 Namur Belgium
| | - Djalal Trache
- Laboratoire des Matériaux Energétiques UER. Procédés Enegétiques Ecole Militaire Polytechnique (EMP) Chahid Abderrahmane Taleb BP 17 16046 Bordj El-Bahri Algiers Algeria
| | - Zineb Mekhalif
- Laboratoire de Chimie et d'Electrochimie des Surfaces NISM Université de Namur 61 Rue de Bruxelles 5000 Namur Belgium
| | - Ahmed Fouzi Tarchoun
- Laboratoire de Propulsion Energétique UER. Procédés Enegétiques Ecole Militaire Polytechnique (EMP) Chahid Abderrahmane Taleb BP 17 16046 Bordj El-Bahri Algiers Algeria
| |
Collapse
|
32
|
Ultrasonic synthesis of bismuth-organic framework intercalated carbon nanofibers: A dual electrocatalyst for trace-level monitoring of nitro hazards. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138280] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
33
|
Prediction effect of ethanol molecules on doxorubicin drug delivery using single-walled carbon nanotube carrier through POPC cell membrane. J Mol Liq 2021. [DOI: 10.1016/j.molliq.2021.115698] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
34
|
Baghayeri M, Amiri A, Karimabadi F, Di Masi S, Maleki B, Adibian F, Pourali AR, Malitesta C. Magnetic MWCNTs-dendrimer: A potential modifier for electrochemical evaluation of As (III) ions in real water samples. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115059] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
35
|
Texture and surface sites of treated and as-prepared SWNT using experimental and simulation methods. ADSORPTION 2021. [DOI: 10.1007/s10450-021-00317-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
36
|
Speranza G. Carbon Nanomaterials: Synthesis, Functionalization and Sensing Applications. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:967. [PMID: 33918769 PMCID: PMC8069879 DOI: 10.3390/nano11040967] [Citation(s) in RCA: 99] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 03/16/2021] [Accepted: 03/17/2021] [Indexed: 02/07/2023]
Abstract
Recent advances in nanomaterial design and synthesis has resulted in robust sensing systems that display superior analytical performance. The use of nanomaterials within sensors has accelerated new routes and opportunities for the detection of analytes or target molecules. Among others, carbon-based sensors have reported biocompatibility, better sensitivity, better selectivity and lower limits of detection to reveal a wide range of organic and inorganic molecules. Carbon nanomaterials are among the most extensively studied materials because of their unique properties spanning from the high specific surface area, high carrier mobility, high electrical conductivity, flexibility, and optical transparency fostering their use in sensing applications. In this paper, a comprehensive review has been made to cover recent developments in the field of carbon-based nanomaterials for sensing applications. The review describes nanomaterials like fullerenes, carbon onions, carbon quantum dots, nanodiamonds, carbon nanotubes, and graphene. Synthesis of these nanostructures has been discussed along with their functionalization methods. The recent application of all these nanomaterials in sensing applications has been highlighted for the principal applicative field and the future prospects and possibilities have been outlined.
Collapse
Affiliation(s)
- Giorgio Speranza
- CMM—FBK, v. Sommarive 18, 38123 Trento, Italy;
- IFN—CNR, CSMFO Lab., via alla Cascata 56/C Povo, 38123 Trento, Italy
- Department of Industrial Engineering, University of Trento, v. Sommarive 9, 38123 Trento, Italy
| |
Collapse
|
37
|
Highly selective simultaneous electrochemical detection of trace level of heavy metals in water samples based on the single-crystalline Co3O4 nanocubes modified electrode. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115159] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
38
|
Sinduja B, Gowthaman NSK, John SA. Fabrication of low-cost sustainable electrocatalyst: a diagnostic tool for multifunctional disorders in human fluids. J Mater Chem B 2021; 8:9502-9511. [PMID: 32996975 DOI: 10.1039/d0tb01681k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
In purine metabolism, the xanthine oxidoreductase enzyme converts hypoxanthine (HXN) to xanthine (XN) and XN to uric acid (UA). This leads to the deposition of UA crystals in several parts of the body and the serum UA level might be associated with various multifunctional disorders. The dietary intake of caffeine (CF) and ascorbic acid (AA) decreases the UA level in the serum, which leads to cellular damage. Hence, it is highly needed to monitor the UA level in the presence of AA, XN, HXN, and CF and vice versa. Considering this sequence of complications, the present paper reports the fabrication of an electrochemical sensor using low-cost N-doped carbon dots (CDs) for the selective and simultaneous determination of UA in the presence of AA, XN, HXN, and CF at the physiological pH. The colloidal solution of CDs was prepared by the pyrolysis of asparagine and fabricated on a GC electrode by cycling the potential from -0.20 to +1.2 V in a solution containing CDs and 0.01 M H2SO4. Here, the surface -NH2 functionalities of CDs were used to make a thin film of CDs on the GC electrode. FT-IR spectroscopy confirmed the involvement of the -NH2 group in the formation of the CD film. HR-TEM analysis depicts that the formed CDs showed spherical particles with a size of 1.67 nm and SEM analysis exhibits the 89 nm CD film on the GC electrode surface. The fabricated CD film was successfully used for the sensitive and selective determination of UA. The determination of UA was achieved selectively in a mixture consisting of AA, XN, HXN, and CF with 50-fold high concentration. The CDs-film fabricated electrode has several benefits over the bare electrode: (i) well-resolved oxidation peaks for five analytes, (ii) boosted sensitivity, (iii) shifted oxidation as well as on-set potentials toward less positive potentials, and (iv) high stability. The practical utility of the present sensor was tested by simultaneously determining the multifactorial disorders-causing agents in human fluids. The electrocatalyst developed in the present study is sustainable and can be used for multiple analyses; besides, the electrochemical method used for the fabrication of the CD film is environmentally benign.
Collapse
Affiliation(s)
- Bharathi Sinduja
- Centre for Nanoscience and Nanotechnology, Department of Chemistry, The Gandhigram Rural Institute, Gandhigram-624 302, Dindigul, Tamilnadu, India.
| | - N S K Gowthaman
- Materials Synthesis and Characterization Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia
| | - S Abraham John
- Centre for Nanoscience and Nanotechnology, Department of Chemistry, The Gandhigram Rural Institute, Gandhigram-624 302, Dindigul, Tamilnadu, India.
| |
Collapse
|
39
|
Sui J, Gandotra N, Xie P, Lin Z, Scharfe C, Javanmard M. Multi-frequency impedance sensing for detection and sizing of DNA fragments. Sci Rep 2021; 11:6490. [PMID: 33753781 PMCID: PMC7985362 DOI: 10.1038/s41598-021-85755-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 01/11/2021] [Indexed: 01/31/2023] Open
Abstract
Electronic biosensors for DNA detection typically utilize immobilized oligonucleotide probes on a signal transducer, which outputs an electronic signal when target molecules bind to probes. However, limitation in probe selectivity and variable levels of non-target material in complex biological samples can lead to nonspecific binding and reduced sensitivity. Here we introduce the integration of 2.8 μm paramagnetic beads with DNA fragments. We apply a custom-made microfluidic chip to detect DNA molecules bound to beads by measuring Impedance Peak Response (IPR) at multiple frequencies. Technical and analytical performance was evaluated using beads containing purified Polymerase Chain Reaction (PCR) products of different lengths (157, 300, 613 bp) with DNA concentration ranging from 0.039 amol to 7.8 fmol. Multi-frequency IPR correlated positively with DNA amounts and was used to calculate a DNA quantification score. The minimum DNA amount of a 300 bp fragment coupled on beads that could be robustly detected was 0.0039 fmol (1.54 fg or 4750 copies/bead). Additionally, our approach allowed distinguishing beads with similar molar concentration DNA fragments of different lengths. Using this impedance sensor, purified PCR products could be analyzed within ten minutes to determine DNA fragment length and quantity based on comparison to a known DNA standard.
Collapse
Affiliation(s)
- Jianye Sui
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 94 Brett Rd, Piscataway, NJ, 08854, USA
| | - Neeru Gandotra
- Department of Genetics, Yale University School of Medicine, 333 Cedar Street, PO Box 208005, New Haven, CT, 06520-8005, USA
| | - Pengfei Xie
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 94 Brett Rd, Piscataway, NJ, 08854, USA
| | - Zhongtian Lin
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 94 Brett Rd, Piscataway, NJ, 08854, USA
| | - Curt Scharfe
- Department of Genetics, Yale University School of Medicine, 333 Cedar Street, PO Box 208005, New Haven, CT, 06520-8005, USA.
| | - Mehdi Javanmard
- Department of Electrical and Computer Engineering, Rutgers University, New Brunswick, 94 Brett Rd, Piscataway, NJ, 08854, USA.
| |
Collapse
|
40
|
Yang M, Wang H, Liu P, Cheng J. A 3D electrochemical biosensor based on Super-Aligned Carbon NanoTube array for point-of-care uric acid monitoring. Biosens Bioelectron 2021; 179:113082. [PMID: 33601134 DOI: 10.1016/j.bios.2021.113082] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 02/03/2021] [Accepted: 02/04/2021] [Indexed: 12/20/2022]
Abstract
Uric acid analysis is extremely important for gout prognosis, diagnosis and treatment. Previous technologies either lack specificity or exhibit poor performance, and thus could not meet the need of Point-of-Care (POC) uric acid monitoring. Here we present for the first time, a novel electrochemical biosensor based on 3D Super-Aligned Carbon NanoTube (SACNT) array to facilitate POC uric acid monitoring. The working electrode of the biosensor is composed of an orderly 3D SACNT array immobilized with uricase through a precipitation and crosslinking procedure. Such biosensor possesses a higher enzyme density, significantly larger contact area with reactants and could maintain the intact SACNT structure and its excellent conductivity after modification. The developed 3D SACNT array electrochemical biosensor benefits from high specific surface area, high electro-catalytic activity and large contact area with analytes, and demonstrates high sensitivity of 518.8 μA/(mM⋅cm2), wide linear range of 100-1000 μM and low limit of detection of 1 μM for uric acid. Dynamic uric acid monitoring has been achieved using the presented biosensor. And the obtained results in serum samples had no significant difference compared with those obtained using the FDA-approved electrochemical analyzer (Paired T-test, p > 0.05). These demonstrated that the technology can potentially be applied in POC monitoring of other biomolecules to improve prognosis, diagnosis and treatment outcomes of metabolic diseases.
Collapse
Affiliation(s)
- Muqun Yang
- Precision Medicine and Healthcare Research Center, Tsinghua-Berkeley Shenzhen Institute(TBSI), Tsinghua University, Shenzhen, 518055, China; Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Han Wang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China.
| | - Peng Liu
- Tsinghua-Foxconn Nanotechnology Research Center & State Key Laboratory of Low-Dimensional Quantum Physics, Department of Physics, Tsinghua University, Beijing, 100084, China
| | - Jing Cheng
- Precision Medicine and Healthcare Research Center, Tsinghua-Berkeley Shenzhen Institute(TBSI), Tsinghua University, Shenzhen, 518055, China; Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
41
|
Deng D, He Y, Li M, Huang L, Zhang J. Preparation of multi-walled carbon nanotubes based magnetic multi-template molecularly imprinted polymer for the adsorption of phthalate esters in water samples. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:5966-5977. [PMID: 32981015 DOI: 10.1007/s11356-020-10970-2] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Accepted: 09/21/2020] [Indexed: 05/17/2023]
Abstract
Taking the advantages of surface imprinting, multi-template imprinting and magnetic separation, a novel magnetic multi-template molecularly imprinted polymer (mag-MMIP@MWCNTs) was prepared by using MWCNTs as support material, Fe3O4 as magnetic core, and dimethyl phthalate (DMP), diethyl phthalate (DEP), and dibutyl phthalate (DBP) as template molecules. This composite was characterized by scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), vibrating sample magnetometer (VSM), and the Brunauer-Emmett-Teller (BET) analysis, and was used for the simultaneous adsorption of DMP, DEP, and DBP in aqueous solution. The effects of solution pH, contact time, PAEs initial concentration, temperature, adsorption selectivity, and reusability were investigated and discussed in detail. The results demonstrated that mag-MMIP@MWCNTs exhibited fast kinetics, good magnetic separation, and excellent selectivity for the adsorption of three phthalate esters (PAEs). The adsorption kinetics followed pseudo second-order kinetic model and the adsorption thermodynamics followed Langmuir isothermal model very well, and the maximum adsorption capacities (Qmax) of DMP, DEP, and DBP were obtained as 0.95, 1.38, and 7.09 mg g-1, respectively. The Scatchard analysis revealed that the template-polymer system had a two-site binding behavior. The adsorption thermodynamic studies indicated that the adsorption processes were exothermic and spontaneous, and dominated by physical adsorption relying on hydrogen bond, hydrophobic interaction, and van der Waals force. Mag-MMIP@MWCNTs also showed good reproducibility and reusability for simultaneous adsorption of the three PAEs. The potential application of mag-MMIP@MWCNTs was proved by the removal of DMP, DEP, and DBP spiked in environmental water samples.
Collapse
Affiliation(s)
- Dongli Deng
- College of Resources and Environment, Southwest University, Chongqing Key Laboratory of Agricultural Resources and Environment, Chongqing, 400715, People's Republic of China
- Chemical Pollution Control and Applied Technology Extension Center of Chongqing Higher Vocational Colleges, Chongqing Industry, Polytechnic College, Chongqing, 401120, People's Republic of China
| | - Yingnan He
- College of Resources and Environment, Southwest University, Chongqing Key Laboratory of Agricultural Resources and Environment, Chongqing, 400715, People's Republic of China
| | - Mingyuan Li
- College of Resources and Environment, Southwest University, Chongqing Key Laboratory of Agricultural Resources and Environment, Chongqing, 400715, People's Republic of China
| | - Ludan Huang
- College of Resources and Environment, Southwest University, Chongqing Key Laboratory of Agricultural Resources and Environment, Chongqing, 400715, People's Republic of China
| | - Jinzhong Zhang
- College of Resources and Environment, Southwest University, Chongqing Key Laboratory of Agricultural Resources and Environment, Chongqing, 400715, People's Republic of China.
| |
Collapse
|
42
|
Yaghoubi A, Ramazani A. Anticancer DOX delivery system based on CNTs: Functionalization, targeting and novel technologies. J Control Release 2020; 327:198-224. [DOI: 10.1016/j.jconrel.2020.08.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 07/31/2020] [Accepted: 08/01/2020] [Indexed: 12/24/2022]
|
43
|
An electrochemical sensor based on plasma-treated zinc oxide nanoflowers for the simultaneous detection of dopamine and diclofenac sodium. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105237] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
44
|
Development of carbon-based sensors for electrochemical quantification of vitamins B2 and B6 at nanomolar levels. CHEMICAL PAPERS 2020. [DOI: 10.1007/s11696-020-01387-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
45
|
Karimzadeh S, Safaei B, Jen TC. Investigate the importance of mechanical properties of SWCNT on doxorubicin anti-cancer drug adsorption for medical application: A molecular dynamic study. J Mol Graph Model 2020; 101:107745. [PMID: 32977299 DOI: 10.1016/j.jmgm.2020.107745] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 08/07/2020] [Accepted: 09/01/2020] [Indexed: 02/07/2023]
Affiliation(s)
- Sina Karimzadeh
- Department of Mechanical Engineering Science, University of Johannesburg, Gauteng, 2006, South Africa.
| | - Babak Safaei
- Department of Mechanical Engineering, Eastern Mediterranean University, Famagusta, North Cyprus via Mersin 10, Turkey.
| | - Tien-Chien Jen
- Department of Mechanical Engineering Science, University of Johannesburg, Gauteng, 2006, South Africa.
| |
Collapse
|
46
|
Wang S, Li M, Li X, Li X, Li X, Li S, Zhang Q, Li H. A functionalized carbon nanotube nanohybrids-based QuEChERS method for detection of pesticide residues in vegetables and fruits. J Chromatogr A 2020; 1631:461526. [PMID: 33002705 DOI: 10.1016/j.chroma.2020.461526] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/01/2020] [Accepted: 09/03/2020] [Indexed: 11/20/2022]
Abstract
A self-separating, analyte-compatible, and efficient clean-up method for QuEChERS extracts was designed and developed based on dispersive solid-phase extraction using a branched polyethylenimine and nanoscale CaSO4 functionalized carboxylated multi-walled carbon nanotubes (MWCNTs) nanohybrids as sorbent. The feasibility of using a self-separating strategy based on the functionalization of sorbent in a purification procedure was analyzed for the first time in this study. Compared to the traditional QuEChERS method, the proposed method is rapid and convenient without centrifugation of numerous samples in the clean-up process. The use of nanohybrids overcame the issue of low recoveries for planar pesticides, which are easily adsorbed using MWCNTs. A better clean-up capability of the nanohybrids to remove matrix interferences and reduce matrix effect was demonstrated compared with that of traditional clean-up sorbent primary secondary amine. The method was validated by determining twenty-eight pesticides in cucumber, cabbage, apple, and orange. Limits of detections were in the range of 0.0001-0.0026 mg/kg. Spike recoveries of pesticides were within 75.3 - 113.6%, with relative standard deviations less than 14.3% at levels 0.01 mg/kg and 0.1 mg/kg. The developed method was successfully applied to monitor the multi-residues.
Collapse
Affiliation(s)
- Sheng Wang
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, No. 18 East Road of North 3rd Ring, Chaoyang District, Beijing 100029, P. R. China
| | - Ming Li
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, No. 18 East Road of North 3rd Ring, Chaoyang District, Beijing 100029, P. R. China
| | - Xiuqin Li
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, No. 18 East Road of North 3rd Ring, Chaoyang District, Beijing 100029, P. R. China
| | - Xianjiang Li
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, No. 18 East Road of North 3rd Ring, Chaoyang District, Beijing 100029, P. R. China
| | - Xiaomin Li
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, No. 18 East Road of North 3rd Ring, Chaoyang District, Beijing 100029, P. R. China
| | - Shuangqing Li
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, No. 18 East Road of North 3rd Ring, Chaoyang District, Beijing 100029, P. R. China
| | - Qinghe Zhang
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, No. 18 East Road of North 3rd Ring, Chaoyang District, Beijing 100029, P. R. China
| | - Hongmei Li
- Division of Chemical Metrology and Analytical Science, National Institute of Metrology, No. 18 East Road of North 3rd Ring, Chaoyang District, Beijing 100029, P. R. China.
| |
Collapse
|
47
|
Mostafa Najafi, Sohouli E, Mousavi F. An Electrochemical Sensor for Fentanyl Detection Based on Multi-Walled Carbon Nanotubes as Electrocatalyst and the Electrooxidation Mechanism. JOURNAL OF ANALYTICAL CHEMISTRY 2020. [DOI: 10.1134/s1061934820090130] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
48
|
Tang Q, Zhu G, Ge Y, Yang J, Huang M, Liu J. AuNPs-polyaniline nanosheet array on carbon nanofiber for the determination of As(III). J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114381] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
49
|
Chakravarthy RD, Mohammed M, Lin HC. Enzyme Instructed Self-assembly of Naphthalimide-dipeptide: Spontaneous Transformation from Nanosphere to Nanotubular Structures that Induces Hydrogelation. Chem Asian J 2020; 15:2696-2705. [PMID: 32652888 DOI: 10.1002/asia.202000575] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 07/06/2020] [Indexed: 11/08/2022]
Abstract
Understanding the structure-morphology relationships of self-assembled nanostructures is crucial for developing materials with the desired chemical and biological functions. Here, phosphate-based naphthalimide (NI) derivatives have been developed for the first time to study the enzyme-instructed self-assembly process. Self-assembly of simple amino acid derivative NI-Yp resulted in non-specific amorphous aggregates in the presence of alkaline phosphatase enzyme. On the other hand, NI-FYp dipeptide forms spherical nanoparticles under aqueous conditions which slowly transformed into partially unzipped nanotubular structures during the enzymatic catalytic process through multiple stages which subsequently resulted in hydrogelation. The self-assembly is driven by the formation of β-sheet type structures stabilized by offset aromatic stacking of NI core and hydrogen bonding interactions which is confirmed with PXRD, Congo-red staining and molecular mechanical calculations. We propose a mechanism for the self-assembly process based on TEM and spectroscopic data. The nanotubular structures of NI-FYp precursor exhibited higher cytotoxicity to human breast cancer cells and human cervical cancer cells when compared to the nanofiber structures of the similar Fmoc-derivative. Overall this study provides a new understanding of the supramolecular self-assembly of small-molecular-weight hydrogelators.
Collapse
Affiliation(s)
- Rajan Deepan Chakravarthy
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, Taiwan, 300, Republic of China
| | - Mohiuddin Mohammed
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, Taiwan, 300, Republic of China
| | - Hsin-Chieh Lin
- Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, Taiwan, 300, Republic of China
| |
Collapse
|
50
|
Navrotskaya AG, Aleksandrova DD, Krivoshapkina EF, Sillanpää M, Krivoshapkin PV. Hybrid Materials Based on Carbon Nanotubes and Nanofibers for Environmental Applications. Front Chem 2020; 8:546. [PMID: 32695748 PMCID: PMC7338791 DOI: 10.3389/fchem.2020.00546] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 05/27/2020] [Indexed: 12/04/2022] Open
Abstract
With the advances in material science, hybrid nanomaterials with unique mechanical, electrical, thermal and optical characteristics have been developed. Among them, hybrids based on filamentous forms of carbon, such as carbon nanotubes and carbon nanofibers, in combination with inorganic nanoparticles attract particular attention. Due to the structure and morphology, charge and energy transfer processes lead to synergistic effects that allow the use of less material with higher productivity. To clarify these issues, this review will summarize and discuss the relevant studies of the use of inorganic compounds of various chemical groups in modifying carbon nanomaterials for ecological applications.
Collapse
Affiliation(s)
| | | | | | - Mika Sillanpää
- Institute of Research and Development, Duy Tan University, Da Nang, Vietnam.,Faculty of Environment and Chemical Engineering, Duy Tan University, Da Nang, Vietnam.,Faculty of Health, Engineering and Sciences, School of Civil Engineering and Surveying, University of Southern Queensland, Toowoomba, QLD, Australia
| | | |
Collapse
|