1
|
Yang Y, Jiang P, Li H, Li W, Li D, Yan X, Zhu X, Ye D, Yang Y, Wang H, Chen R, Liao Q. Photothermal-Driven Droplet Manipulation: A Perspective. J Phys Chem Lett 2024; 15:8877-8895. [PMID: 39171577 DOI: 10.1021/acs.jpclett.4c01977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/23/2024]
Abstract
Optofluidics, which utilizes the interactions between light and fluids to realize various functions, has garnered increasing attention owing to the advantages of operational simplicity, exceptional flexibility, rapid response, etc. As one of the typical light-fluid interactions, the localized photothermal effect serving as a stimulus has been widely used for fluid manipulation. Particularly, significant progress on photothermal-driven droplet manipulation has been made. In this perspective, recent advancements in localized photothermal effect driven droplet manipulation are summarized. First, the photothermal manipulation of droplets on open surfaces is outlined. An attractive droplet manipulation of light droplet levitation above the gas-liquid interface via localized photothermal effect is then discussed. Besides, the photothermal-driven manipulation of droplets in an immiscible liquid phase is also discussed. Although promising, further development of photothermal-driven droplet manipulation is still needed. The challenges and perspectives of this light droplet manipulation strategy for broad implementation are summarized, which will help future studies and applications.
Collapse
Affiliation(s)
- Yijing Yang
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Pengcheng Jiang
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Haonan Li
- Institute of Laser Manufacturing, Henan Academy of Sciences, Zhengzhou 450046, P. R. China
| | - Wei Li
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Dongliang Li
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Xiao Yan
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Xun Zhu
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Dingding Ye
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Yang Yang
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Hong Wang
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Rong Chen
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| | - Qiang Liao
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education, Chongqing 400030, China
- Institute of Engineering Thermophysics, School of Energy and Power Engineering, Chongqing University, Chongqing 400030, China
| |
Collapse
|
2
|
Albin D, Buecherl L, Kochavi E, Niehaus E, Novack S, Uragoda S, Myers CJ, Alistar M. PhageBox: An Open Source Digital Microfluidic Extension With Applications for Phage Discovery. IEEE Trans Biomed Eng 2024; 71:217-226. [PMID: 37450356 DOI: 10.1109/tbme.2023.3295418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/18/2023]
Abstract
OBJECTIVE Recent advancements demonstrate the significant role of digital microfluidics in automating laboratory work with DNA and on-site viral testing. However, since commercially available instruments are limited to droplet manipulation, our work addresses the need for accelerated integration of other components, such as temperature control, that can expand the application domain. METHODS We developed PhageBox-an accessible device that can be used as a biochip extension. At hardware level, PhageBox integrates temperature and electromagnetic control modules. At software level, PhageBox is controlled by embedded software containing a unique model for bio-protocol programming, and a graphical user interface for visual device feedback and operation. RESULTS To evaluate PhageBox's efficacy for biomedical applications, we performed functional testing. Similarly, we validated the temperature control using thermography, obtaining a range of ±0.2[Formula: see text]. The electromagnets produced a magnetic force of 15 milliTesla, demonstrating precise immobilization of magnetic beads. We show the potential of PhageBox for bacteriophage research through three initial protocols: a universal framework for PCR, T7 bacteriophage restriction enzyme digestion, and concentrating ϕX174 RF genomic DNA. CONCLUSION Our work presents an open-source hardware and software extension for digital microfluidics devices. This extension integrates temperature and electromagnetic modules, demonstrating efficacy in biomedical applications and potential for bacteriophage research. SIGNIFICANCE We developed PhageBox to be accessible: the components are off-the-shelf at a low cost ( ≤ $200), and the hardware designs and software code are open-source. With the long aim of ensuring reproducibility and accelerating collaboration, we also provide a DIY-build document.
Collapse
|
3
|
Ho M, Sathishkumar N, Sklavounos AA, Sun J, Yang I, Nichols KP, Wheeler AR. Digital microfluidics with distance-based detection - a new approach for nucleic acid diagnostics. LAB ON A CHIP 2023; 24:63-73. [PMID: 37987330 DOI: 10.1039/d3lc00683b] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
Abstract
There is great enthusiasm for using loop-mediated isothermal amplification (LAMP) in point-of-care nucleic acid amplification tests (POC NAATs), as an alternative to PCR. While isothermal amplification techniques like LAMP eliminate the need for rapid temperature cycling in a portable format, these systems are still plagued by requirements for dedicated optical detection apparatus for analysis and manual off-chip sample processing. Here, we developed a new microfluidic system for LAMP-based POC NAATs to address these limitations. The new system combines digital microfluidics (DMF) with distance-based detection (DBD) for direct signal readout. This is the first report of the use of (i) LAMP or (ii) DMF with DBD - thus, we describe a number of characterization steps taken to determine optimal combinations of reagents, materials, and processes for reliable operation. For example, DBD was found to be quite sensitive to background signals from low molecular weight LAMP products; thus, a Capto™ adhere bead-based clean-up procedure was developed to isolate the desirable high-molecular-weight products for analysis. The new method was validated by application to detection of SARS-CoV-2 in saliva. The method was able to distinguish between saliva containing no virus, saliva containing a low viral load (104 genome copies per mL), and saliva containing a high viral load (108 copies per mL), all in an automated system that does not require detection apparatus for analysis. We propose that the combination of DMF with distance-based detection may be a powerful one for implementing a variety of POC NAATs or for other applications in the future.
Collapse
Affiliation(s)
- Man Ho
- Department of Chemistry, University of Toronto, 80. St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
| | - N Sathishkumar
- Department of Chemistry, University of Toronto, 80. St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
| | - Alexandros A Sklavounos
- Department of Chemistry, University of Toronto, 80. St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
| | - Jianxian Sun
- Department of Chemistry, University of Toronto, 80. St. George Street, Toronto, Ontario, M5S 3H6, Canada.
| | - Ivy Yang
- Department of Chemical Engineering & Applied Chemistry, University of Toronto, 200 College Street, Toronto, Ontario, M5S 3E5, Canada
| | | | - Aaron R Wheeler
- Department of Chemistry, University of Toronto, 80. St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
- Institute of Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario, M5S 3G9, Canada
| |
Collapse
|
4
|
Wan L, Li M, Law MK, Mak PI, Martins RP, Jia Y. Sub-5-Minute Ultrafast PCR using Digital Microfluidics. Biosens Bioelectron 2023; 242:115711. [PMID: 37797533 DOI: 10.1016/j.bios.2023.115711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 09/08/2023] [Accepted: 09/25/2023] [Indexed: 10/07/2023]
Abstract
The development of a rapid and reliable polymerase chain reaction (PCR) method for point-of-care (POC) diagnosis is crucial for the timely identification of pathogens. Microfluidics, which involves the manipulation of small volumes of fluidic samples, has been shown to be an ideal approach for POC analysis. Among the various microfluidic platforms available, digital microfluidics (DMF) offers high degree of configurability in manipulating μL/nL-scale liquid and achieving automation. However, the successful implementation of ultrafast PCR on DMF platforms presents challenges due to inherent system instability. In this study, we developed a robust and ultrafast PCR in 3.7-5 min with a detection sensitivity comparable to conventional PCR. Specifically, the implementation of the pincer heating scheme homogenises the temperature within a drop. The utilization of a μm-scale porous hydrophobic membrane suppresses the formation of bubbles under high temperatures. The design of a groove around the high-temperature zone effectively mitigates the temperature interference. The integration of a soluble sensor into the droplets provides an accurate and instant in-drop temperature sensing. We envision that the fast, robust, sensitive, and automatic DMF system will empower the POC testing for infectious diseases.
Collapse
Affiliation(s)
- Liang Wan
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China
| | - Mingzhong Li
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Silergy Semiconductor (Macau) Limited, Macao, China
| | - Man-Kay Law
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Pui-In Mak
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Rui P Martins
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China; On Leave from Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Yanwei Jia
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China; MoE Frontiers Science Center for Precision Oncology, University of Macau, Macao, China.
| |
Collapse
|
5
|
Coelho BJ, Neto JP, Sieira B, Moura AT, Fortunato E, Martins R, Baptista PV, Igreja R, Águas H. Hybrid Digital-Droplet Microfluidic Chip for Applications in Droplet Digital Nucleic Acid Amplification: Design, Fabrication and Characterization. SENSORS (BASEL, SWITZERLAND) 2023; 23:4927. [PMID: 37430841 DOI: 10.3390/s23104927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 05/05/2023] [Accepted: 05/17/2023] [Indexed: 07/12/2023]
Abstract
Microfluidic-based platforms have become a hallmark for chemical and biological assays, empowering micro- and nano-reaction vessels. The fusion of microfluidic technologies (digital microfluidics, continuous-flow microfluidics, and droplet microfluidics, just to name a few) presents great potential for overcoming the inherent limitations of each approach, while also elevating their respective strengths. This work exploits the combination of digital microfluidics (DMF) and droplet microfluidics (DrMF) on a single substrate, where DMF enables droplet mixing and further acts as a controlled liquid supplier for a high-throughput nano-liter droplet generator. Droplet generation is performed at a flow-focusing region, operating on dual pressure: negative pressure applied to the aqueous phase and positive pressure applied to the oil phase. We evaluate the droplets produced with our hybrid DMF-DrMF devices in terms of droplet volume, speed, and production frequency and further compare them with standalone DrMF devices. Both types of devices enable customizable droplet production (various volumes and circulation speeds), yet hybrid DMF-DrMF devices yield more controlled droplet production while achieving throughputs that are similar to standalone DrMF devices. These hybrid devices enable the production of up to four droplets per second, which reach a maximum circulation speed close to 1540 µm/s and volumes as low as 0.5 nL.
Collapse
Affiliation(s)
- Beatriz J Coelho
- CENIMAT|i3N, Department of Materials Science, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon and CEMOP/UNINOVA, 2829-516 Caparica, Portugal
- UCIBIO, I4HB, Department of Life Sciences, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon, 2829-516 Caparica, Portugal
| | - Joana P Neto
- CENIMAT|i3N, Department of Materials Science, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon and CEMOP/UNINOVA, 2829-516 Caparica, Portugal
| | - Bárbara Sieira
- CENIMAT|i3N, Department of Materials Science, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon and CEMOP/UNINOVA, 2829-516 Caparica, Portugal
| | - André T Moura
- CENIMAT|i3N, Department of Materials Science, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon and CEMOP/UNINOVA, 2829-516 Caparica, Portugal
| | - Elvira Fortunato
- CENIMAT|i3N, Department of Materials Science, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon and CEMOP/UNINOVA, 2829-516 Caparica, Portugal
| | - Rodrigo Martins
- CENIMAT|i3N, Department of Materials Science, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon and CEMOP/UNINOVA, 2829-516 Caparica, Portugal
| | - Pedro V Baptista
- UCIBIO, I4HB, Department of Life Sciences, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon, 2829-516 Caparica, Portugal
| | - Rui Igreja
- CENIMAT|i3N, Department of Materials Science, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon and CEMOP/UNINOVA, 2829-516 Caparica, Portugal
| | - Hugo Águas
- CENIMAT|i3N, Department of Materials Science, NOVA School of Science and Technology, Campus de Caparica, NOVA University of Lisbon and CEMOP/UNINOVA, 2829-516 Caparica, Portugal
| |
Collapse
|
6
|
Tong Z, Shen C, Li Q, Yin H, Mao H. Combining sensors and actuators with electrowetting-on-dielectric (EWOD): advanced digital microfluidic systems for biomedical applications. Analyst 2023; 148:1399-1421. [PMID: 36752059 DOI: 10.1039/d2an01707e] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The concept of digital microfluidics (DMF) enables highly flexible and precise droplet manipulation at a picoliter scale, making DMF a promising approach to realize integrated, miniaturized "lab-on-a-chip" (LOC) systems for research and clinical purposes. Owing to its simplicity and effectiveness, electrowetting-on-dielectric (EWOD) is one of the most commonly studied and applied effects to implement DMF. However, complex biomedical assays usually require more sophisticated sample handling and detection capabilities than basic EWOD manipulation. Alternatively, combined systems integrating EWOD actuators and other fluidic handling techniques are essential for bringing DMF into practical use. In this paper, we briefly review the main approaches for the integration/combination of EWOD with other microfluidic manipulation methods or additional external fields for specified biomedical applications. The form of integration ranges from independently operating sub-systems to fully coupled hybrid actuators. The corresponding biomedical applications of these works are also summarized to illustrate the significance of these innovative combination attempts.
Collapse
Affiliation(s)
- Zhaoduo Tong
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Chuanjie Shen
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Qiushi Li
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
| | - Hao Yin
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Hongju Mao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
| |
Collapse
|
7
|
Shen R, Lv A, Yi S, Wang P, Mak PI, Martins RP, Jia Y. Nucleic acid analysis on electrowetting-based digital microfluidics. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
8
|
Lin YH, Liao XJ, Chang W, Chiou CC. Ultrafast DNA Amplification Using Microchannel Flow-Through PCR Device. BIOSENSORS 2022; 12:bios12050303. [PMID: 35624604 PMCID: PMC9138433 DOI: 10.3390/bios12050303] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 04/29/2022] [Accepted: 05/04/2022] [Indexed: 05/17/2023]
Abstract
Polymerase chain reaction (PCR) is limited by the long reaction time for point-of-care. Currently, commercial benchtop rapid PCR requires 30−40 min, and this time is limited by the absence of rapid and stable heating and cooling platforms rather than the biochemical reaction kinetics. This study develops an ultrafast PCR (<3 min) platform using flow-through microchannel chips. An actin gene amplicon with a length of 151 base-pairs in the whole genome was used to verify the ultrafast PCR microfluidic chip. The results demonstrated that the channel of 56 μm height can provide fast heat conduction and the channel length should not be short. Under certain denaturation and annealing/extension times, a short channel design will cause the sample to drive slowly in the microchannel with insufficient pressure in the channel, causing the fluid to generate bubbles in the high-temperature zone and subsequently destabilizing the flow. The chips used in the experiment can complete 40 thermal cycles within 160 s through a design with the 56 µm channel height and with each thermal circle measuring 4 cm long. The calculation shows that the DNA extension speed is ~60 base-pairs/s, which is consistent with the theoretical speed of the Klen Taq extension used, and the detection limit can reach 67 copies. The heat transfer time of the reagent on this platform is very short. The simple chip design and fabrication are suitable for the development of commercial ultrafast PCR chips.
Collapse
Affiliation(s)
- Yen-Heng Lin
- Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan 333, Taiwan;
- Department of Laboratory Medicine, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan
- Correspondence: (Y.-H.L.); (C.-C.C.)
| | - Xiang-Jun Liao
- Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan 333, Taiwan;
| | - Wei Chang
- Master and PhD Program in Biotechnology Industry, College of Medicine, Chang Gung University, Taoyuan 333, Taiwan;
| | - Chiuan-Chian Chiou
- Master and PhD Program in Biotechnology Industry, College of Medicine, Chang Gung University, Taoyuan 333, Taiwan;
- Department of Medical Biotechnology and Laboratory Science, College of Medicine, Chang Gung University, Taoyuan 333, Taiwan
- Department of Thoracic Medicine, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan
- Correspondence: (Y.-H.L.); (C.-C.C.)
| |
Collapse
|
9
|
Narahari T, Dahmer J, Sklavounos A, Kim T, Satkauskas M, Clotea I, Ho M, Lamanna J, Dixon C, Rackus DG, Silva SJRD, Pena L, Pardee K, Wheeler AR. Portable sample processing for molecular assays: application to Zika virus diagnostics. LAB ON A CHIP 2022; 22:1748-1763. [PMID: 35357372 DOI: 10.1039/d1lc01068a] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
This paper introduces a digital microfluidic (DMF) platform for portable, automated, and integrated Zika viral RNA extraction and amplification. The platform features reconfigurable DMF cartridges offering a closed, humidified environment for sample processing at elevated temperatures, as well as programmable control instrumentation with a novel thermal cycling unit regulated using a proportional integral derivative (PID) feedback loop. The system operates on 12 V DC power, which can be supplied by rechargeable battery packs for remote testing. The DMF system was optimized for an RNA processing pipeline consisting of the following steps: 1) magnetic-bead based RNA extraction from lysed plasma samples, 2) RNA clean-up, and 3) integrated, isothermal amplification of Zika RNA. The DMF pipeline was coupled to a paper-based, colorimetric cell-free protein expression assay for amplified Zika RNA mediated by toehold switch-based sensors. Blinded laboratory evaluation of Zika RNA spiked in human plasma yielded a sensitivity and specificity of 100% and 75% respectively. The platform was then transported to Recife, Brazil for evaluation with infectious Zika viruses, which were detected at the 100 PFU mL-1 level from a 5 μL sample (equivalent to an RT-qPCR cycle threshold value of 32.0), demonstrating its potential as a sample processing platform for miniaturized diagnostic testing.
Collapse
Affiliation(s)
- Tanya Narahari
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
| | - Joshua Dahmer
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
| | - Alexandros Sklavounos
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
| | - Taehyeong Kim
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
| | - Monika Satkauskas
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
| | - Ioana Clotea
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
| | - Man Ho
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
| | - Julian Lamanna
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
| | - Christopher Dixon
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
| | - Darius G Rackus
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Leslie Dan Faculty of Pharmacy, University of Toronto, 144 College Street, Toronto, Ontario, M5S 3M2, Canada
| | - Severino Jefferson Ribeiro da Silva
- Department of Virology, Aggeu Magalhães Institute (IAM), Oswaldo Cruz Institute (FIOCRUZ Pernambuco), Av. Professor Moraes Rego, s/n - Cidade Universitária, Recife, PE, CEP 50.740-465, Brazil
| | - Lindomar Pena
- Department of Virology, Aggeu Magalhães Institute (IAM), Oswaldo Cruz Institute (FIOCRUZ Pernambuco), Av. Professor Moraes Rego, s/n - Cidade Universitária, Recife, PE, CEP 50.740-465, Brazil
| | - Keith Pardee
- Leslie Dan Faculty of Pharmacy, University of Toronto, 144 College Street, Toronto, Ontario, M5S 3M2, Canada
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, M5S 3G8 Canada
| | - Aaron R Wheeler
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College Street, Toronto, Ontario, M5S 3E1, Canada
- Institute for Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario, M5S 3G9, Canada
| |
Collapse
|
10
|
Cheng H, Liu H, Li W, Li M. Recent advances in magnetic digital microfluidic platforms. Electrophoresis 2021; 42:2329-2346. [PMID: 34196022 DOI: 10.1002/elps.202100088] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 06/22/2021] [Accepted: 06/25/2021] [Indexed: 12/14/2022]
Abstract
Magnetic Digital microfluidics (DMF), which enables the manipulation of droplets containing different types of samples and reagents by permanent magnets or electromagnet arrays, has been used as a promising platform technology for bioanalytical and preparative assays. This is due to its unique advantages such as simple and "power free" operation, easy assembly, great compatibility with auto control systems, and dual functionality of magnetic particles (actuation and target attachment). Over the past decades, magnetic DMF technique has gained a widespread attention in many fields such as sample-to-answer molecular diagnostics, immunoassays, cell assays, on-demand chemical synthesis, and single-cell manipulation. In the first part of this review, we summarised features of magnetic DMF. Then, we introduced the actuation mechanisms and fabrication of magnetic DMF. Furthermore, we discussed five main applications of magnetic DMF, namely drug screening, protein assays, polymerase chain reaction (PCR), cell manipulation, and chemical analysis and synthesis. In the last part of the review, current challenges and limitations with magnetic DMF technique were discussed, such as biocompatibility, automation of microdroplet control systems, and microdroplet evaporation, with an eye on towards future development.
Collapse
Affiliation(s)
- Hao Cheng
- Laboratoire de Thermique et Energie de Nantes (LTEN), UMR CNRS 6607, Polytech' Nantes-Université de Nantes, Nantes Cedex 03, France.,School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, Australia
| | - Hangrui Liu
- Department of Physics and Astronomy, Macquarie University, Sydney, New South Wales, Australia
| | - Weihua Li
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, Australia
| | - Ming Li
- School of Engineering, Macquarie University, Sydney, New South Wales, Australia.,Biomolecular Discovery Research Centre, Macquarie University, Sydney, New South Wales, Australia
| |
Collapse
|
11
|
Rui X, Song S, Wang W, Zhou J. Applications of electrowetting-on-dielectric (EWOD) technology for droplet digital PCR. BIOMICROFLUIDICS 2020; 14:061503. [PMID: 33312327 PMCID: PMC7719047 DOI: 10.1063/5.0021177] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Accepted: 11/24/2020] [Indexed: 05/25/2023]
Abstract
Digital microfluidics is an elegant technique based on single droplets for the design, composition, and manipulation of microfluidic systems. In digital microfluidics, especially in the electrowetting on dielectric (EWOD) system, each droplet acts as an independent reactor, which enables a wide range of multiple parallel biological and chemical reactions at the microscale. EWOD digital microfluidics reduces reagent and energy consumption, accelerates analysis, enables point-of-care diagnostic, simplifies integration with sensors, etc. Such a digital microfluidic system is especially relevant for droplet digital PCR (ddPCR), thanks to its nanoliter droplets and well-controlled volume distribution. At low DNA concentration, these small volumes allow less than one DNA strand per droplet on average (limited dilution) so that after a fixed number of PCR cycles (endpoint PCR), only the DNA in droplets containing the sequence of interest has been amplified and can be detected by fluorescence to yield an accurate count of the sequences of interest using statistical models. Focusing on ddPCR, this article summarizes the latest development and research on EWOD technology for droplet PCR over the last decade.
Collapse
Affiliation(s)
| | | | | | - Jia Zhou
- Author to whom correspondence should be addressed:
| |
Collapse
|
12
|
Abstract
With the rapid development of high technology, chemical science is not as it used to be a century ago. Many chemists acquire and utilize skills that are well beyond the traditional definition of chemistry. The digital age has transformed chemistry laboratories. One aspect of this transformation is the progressing implementation of electronics and computer science in chemistry research. In the past decade, numerous chemistry-oriented studies have benefited from the implementation of electronic modules, including microcontroller boards (MCBs), single-board computers (SBCs), professional grade control and data acquisition systems, as well as field-programmable gate arrays (FPGAs). In particular, MCBs and SBCs provide good value for money. The application areas for electronic modules in chemistry research include construction of simple detection systems based on spectrophotometry and spectrofluorometry principles, customizing laboratory devices for automation of common laboratory practices, control of reaction systems (batch- and flow-based), extraction systems, chromatographic and electrophoretic systems, microfluidic systems (classical and nonclassical), custom-built polymerase chain reaction devices, gas-phase analyte detection systems, chemical robots and drones, construction of FPGA-based imaging systems, and the Internet-of-Chemical-Things. The technology is easy to handle, and many chemists have managed to train themselves in its implementation. The only major obstacle in its implementation is probably one's imagination.
Collapse
Affiliation(s)
- Gurpur Rakesh D Prabhu
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan.,Department of Applied Chemistry, National Chiao Tung University, 1001 University Road, Hsinchu, 300, Taiwan
| | - Pawel L Urban
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan.,Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan
| |
Collapse
|
13
|
Kothamachu VB, Zaini S, Muffatto F. Role of Digital Microfluidics in Enabling Access to Laboratory Automation and Making Biology Programmable. SLAS Technol 2020; 25:411-426. [PMID: 32584152 DOI: 10.1177/2472630320931794] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Digital microfluidics (DMF) is a liquid handling technique that has been demonstrated to automate biological experimentation in a low-cost, rapid, and programmable manner. This review discusses the role of DMF as a "digital bioconverter"-a tool to connect the digital aspects of the design-build-learn cycle with the physical execution of experiments. Several applications are reviewed to demonstrate the utility of DMF as a digital bioconverter, namely, genetic engineering, sample preparation for sequencing and mass spectrometry, and enzyme-, immuno-, and cell-based screening assays. These applications show that DMF has great potential in the role of a centralized execution platform in a fully integrated pipeline for the production of novel organisms and biomolecules. In this paper, we discuss how the function of a DMF device within such a pipeline is highly dependent on integration with different sensing techniques and methodologies from machine learning and big data. In addition to that, we examine how the capacity of DMF can in some cases be limited by known technical and operational challenges and how consolidated efforts in overcoming these challenges will be key to the development of DMF as a major enabling technology in the computer-aided biology framework.
Collapse
|
14
|
Husser MC, Vo PQN, Sinha H, Ahmadi F, Shih SCC. An Automated Induction Microfluidics System for Synthetic Biology. ACS Synth Biol 2018. [PMID: 29516725 DOI: 10.1021/acssynbio.8b00025] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The expression of a recombinant gene in a host organism through induction can be an extensively manual and labor-intensive procedure. Several methods have been developed to simplify the protocol, but none has fully replaced the traditional IPTG-based induction. To simplify this process, we describe the development of an autoinduction platform based on digital microfluidics. This system consists of a 600 nm LED and a light sensor to enable the real-time monitoring of the optical density (OD) samples coordinated with the semicontinuous mixing of a bacterial culture. A hand-held device was designed as a microbioreactor to culture cells and to measure the OD of the bacterial culture. In addition, it serves as a platform for the analysis of regulated protein expression in E. coli without the requirement of standardized well-plates or pipetting-based platforms. Here, we report for the first time, a system that offers great convenience without the user to physically monitor the culture or to manually add inducer at specific times. We characterized our system by looking at several parameters (electrode designs, gap height, and growth rates) required for an autoinducible system. As a first step, we carried out an automated induction optimization assay using a RFP reporter gene to identify conditions suitable for our system. Next, we used our system to identify active thermophilic β-glucosidase enzymes that may be suitable candidates for biomass hydrolysis. Overall, we believe that this platform may be useful for synthetic biology applications that require regulating and analyzing expression of heterologous genes for strain optimization.
Collapse
Affiliation(s)
- Mathieu C. Husser
- Department of Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
| | - Philippe Q. N. Vo
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G 1M8, Canada
| | - Hugo Sinha
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G 1M8, Canada
| | - Fatemeh Ahmadi
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G 1M8, Canada
| | - Steve C. C. Shih
- Department of Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B 1R6, Canada
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G 1M8, Canada
| |
Collapse
|
15
|
Digital Microfluidics for Nucleic Acid Amplification. SENSORS 2017; 17:s17071495. [PMID: 28672827 PMCID: PMC5539496 DOI: 10.3390/s17071495] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2017] [Revised: 06/17/2017] [Accepted: 06/22/2017] [Indexed: 01/08/2023]
Abstract
Digital Microfluidics (DMF) has emerged as a disruptive methodology for the control and manipulation of low volume droplets. In DMF, each droplet acts as a single reactor, which allows for extensive multiparallelization of biological and chemical reactions at a much smaller scale. DMF devices open entirely new and promising pathways for multiplex analysis and reaction occurring in a miniaturized format, thus allowing for healthcare decentralization from major laboratories to point-of-care with accurate, robust and inexpensive molecular diagnostics. Here, we shall focus on DMF platforms specifically designed for nucleic acid amplification, which is key for molecular diagnostics of several diseases and conditions, from pathogen identification to cancer mutations detection. Particular attention will be given to the device architecture, materials and nucleic acid amplification applications in validated settings.
Collapse
|
16
|
Ahrberg CD, Manz A, Chung BG. Polymerase chain reaction in microfluidic devices. LAB ON A CHIP 2016; 16:3866-3884. [PMID: 27713993 DOI: 10.1039/c6lc00984k] [Citation(s) in RCA: 158] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The invention of the polymerase chain reaction (PCR) has caused a revolution in molecular biology, giving access to a method of amplifying deoxyribonucleic acid (DNA) molecules across several orders of magnitude. Since the first application of PCR in a microfluidic device was developed in 1998, an increasing number of researchers have continued the development of microfluidic PCR systems. In this review, we introduce recent developments in microfluidic-based space and time domain devices as well as discuss various designs integrated with multiple functions for sample preparation and detection. The development of isothermal nucleic acid amplification and digital PCR microfluidic devices within the last five years is also highlighted. Furthermore, we introduce various commercial microfluidic PCR devices.
Collapse
Affiliation(s)
| | - Andreas Manz
- Microfluidics group, KIST-Europe, Saarbrücken, Germany and Mechanotronics Department, Universität des Saarlandes, Saarbrücken, Germany
| | - Bong Geun Chung
- Department of Mechanical Engineering, Sogang University, Seoul, Korea.
| |
Collapse
|
17
|
Samiei E, Tabrizian M, Hoorfar M. A review of digital microfluidics as portable platforms for lab-on a-chip applications. LAB ON A CHIP 2016; 16:2376-96. [PMID: 27272540 DOI: 10.1039/c6lc00387g] [Citation(s) in RCA: 212] [Impact Index Per Article: 23.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Following the development of microfluidic systems, there has been a high tendency towards developing lab-on-a-chip devices for biochemical applications. A great deal of effort has been devoted to improve and advance these devices with the goal of performing complete sets of biochemical assays on the device and possibly developing portable platforms for point of care applications. Among the different microfluidic systems used for such a purpose, digital microfluidics (DMF) shows high flexibility and capability of performing multiplex and parallel biochemical operations, and hence, has been considered as a suitable candidate for lab-on-a-chip applications. In this review, we discuss the most recent advances in the DMF platforms, and evaluate the feasibility of developing multifunctional packages for performing complete sets of processes of biochemical assays, particularly for point-of-care applications. The progress in the development of DMF systems is reviewed from eight different aspects, including device fabrication, basic fluidic operations, automation, manipulation of biological samples, advanced operations, detection, biological applications, and finally, packaging and portability of the DMF devices. Success in developing the lab-on-a-chip DMF devices will be concluded based on the advances achieved in each of these aspects.
Collapse
Affiliation(s)
- Ehsan Samiei
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V 1V7, Canada.
| | | | | |
Collapse
|
18
|
Li R, Lv X, Zhang X, Saeed O, Deng Y. Microfluidics for cell-cell interactions: A review. Front Chem Sci Eng 2015. [DOI: 10.1007/s11705-015-1550-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
19
|
Liu C, Choi K, Kang Y, Kim J, Fobel C, Seale B, Campbell JL, Covey TR, Wheeler AR. Direct Interface between Digital Microfluidics and High Performance Liquid Chromatography-Mass Spectrometry. Anal Chem 2015; 87:11967-72. [PMID: 26595766 DOI: 10.1021/acs.analchem.5b03616] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
We introduce an automated method to facilitate in-line coupling of digital microfluidics (DMF) with HPLC-MS, using a custom, 3D-printed manifold and a custom plugin to the popular open-source control system, DropBot. The method was designed to interface directly with commercial autosamplers (with no prior modification), suggesting that it will be widely accessible for end-users. The system was demonstrated to be compatible with samples dissolved in aqueous buffers and neat methanol and was validated by application to a common steroid-labeling derivatization reaction. We propose that the methods described here will be useful for a wide range of applications, combining the automated sample processing power of DMF with the resolving and analytical capacity of HPLC-MS.
Collapse
Affiliation(s)
- Chang Liu
- Department of Chemistry, University of Toronto , 80 St. George Street, Toronto, Ontario M5S 3H6, Canada.,SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada
| | - Kihwan Choi
- Department of Chemistry, University of Toronto , 80 St. George Street, Toronto, Ontario M5S 3H6, Canada.,Donnelly Centre for Cellular and Biomolecular Research, 160 College Street, Toronto, Ontario M5S 3E1, Canada
| | - Yang Kang
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada
| | - Jihye Kim
- Department of Chemistry, University of Toronto , 80 St. George Street, Toronto, Ontario M5S 3H6, Canada
| | - Christian Fobel
- Department of Chemistry, University of Toronto , 80 St. George Street, Toronto, Ontario M5S 3H6, Canada.,Donnelly Centre for Cellular and Biomolecular Research, 160 College Street, Toronto, Ontario M5S 3E1, Canada
| | - Brendon Seale
- Department of Chemistry, University of Toronto , 80 St. George Street, Toronto, Ontario M5S 3H6, Canada
| | | | - Thomas R Covey
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada
| | - Aaron R Wheeler
- Department of Chemistry, University of Toronto , 80 St. George Street, Toronto, Ontario M5S 3H6, Canada.,Institute of Biomaterials and Biomedical Engineering, University of Toronto , 164 College Street, Toronto, Ontario M5S 3G9, Canada.,Donnelly Centre for Cellular and Biomolecular Research, 160 College Street, Toronto, Ontario M5S 3E1, Canada
| |
Collapse
|
20
|
Shih SCC, Goyal G, Kim PW, Koutsoubelis N, Keasling JD, Adams PD, Hillson NJ, Singh AK. A Versatile Microfluidic Device for Automating Synthetic Biology. ACS Synth Biol 2015; 4:1151-64. [PMID: 26075958 DOI: 10.1021/acssynbio.5b00062] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
New microbes are being engineered that contain the genetic circuitry, metabolic pathways, and other cellular functions required for a wide range of applications such as producing biofuels, biobased chemicals, and pharmaceuticals. Although currently available tools are useful in improving the synthetic biology process, further improvements in physical automation would help to lower the barrier of entry into this field. We present an innovative microfluidic platform for assembling DNA fragments with 10× lower volumes (compared to that of current microfluidic platforms) and with integrated region-specific temperature control and on-chip transformation. Integration of these steps minimizes the loss of reagents and products compared to that with conventional methods, which require multiple pipetting steps. For assembling DNA fragments, we implemented three commonly used DNA assembly protocols on our microfluidic device: Golden Gate assembly, Gibson assembly, and yeast assembly (i.e., TAR cloning, DNA Assembler). We demonstrate the utility of these methods by assembling two combinatorial libraries of 16 plasmids each. Each DNA plasmid is transformed into Escherichia coli or Saccharomyces cerevisiae using on-chip electroporation and further sequenced to verify the assembly. We anticipate that this platform will enable new research that can integrate this automated microfluidic platform to generate large combinatorial libraries of plasmids and will help to expedite the overall synthetic biology process.
Collapse
Affiliation(s)
- Steve C. C. Shih
- Sandia National Laboratories, 7011 East Avenue, Livermore, California 94550, United States
| | - Garima Goyal
- Physical
Bioscience Division, Lawrence Berkeley National Laboratory, 1 Cyclotron
Road, Berkeley, California 94720, United States
| | - Peter W. Kim
- Sandia National Laboratories, 7011 East Avenue, Livermore, California 94550, United States
| | - Nicolas Koutsoubelis
- Physical
Bioscience Division, Lawrence Berkeley National Laboratory, 1 Cyclotron
Road, Berkeley, California 94720, United States
| | - Jay D. Keasling
- Physical
Bioscience Division, Lawrence Berkeley National Laboratory, 1 Cyclotron
Road, Berkeley, California 94720, United States
- Department of Chemical & Biomolecular Engineering, Department of Bioengineering, University of California, Berkeley, California 94720, United States
| | - Paul D. Adams
- Physical
Bioscience Division, Lawrence Berkeley National Laboratory, 1 Cyclotron
Road, Berkeley, California 94720, United States
| | - Nathan J. Hillson
- Physical
Bioscience Division, Lawrence Berkeley National Laboratory, 1 Cyclotron
Road, Berkeley, California 94720, United States
| | - Anup K. Singh
- Sandia National Laboratories, 7011 East Avenue, Livermore, California 94550, United States
| |
Collapse
|
21
|
Abstract
This minireview discusses universal electronic modules (generic programmable units) and their use by analytical chemists to construct inexpensive, miniature or automated devices. Recently, open-source platforms have gained considerable popularity among tech-savvy chemists because their implementation often does not require expert knowledge and investment of funds. Thus, chemistry students and researchers can easily start implementing them after a few hours of reading tutorials and trial-and-error. Single-board microcontrollers and micro-computers such as Arduino, Teensy, Raspberry Pi or BeagleBone enable collecting experimental data with high precision as well as efficient control of electric potentials and actuation of mechanical systems. They are readily programmed using high-level languages, such as C, C++, JavaScript or Python. They can also be coupled with mobile consumer electronics, including smartphones as well as teleinformatic networks. More demanding analytical tasks require fast signal processing. Field-programmable gate arrays enable efficient and inexpensive prototyping of high-performance analytical platforms, thus becoming increasingly popular among analytical chemists. This minireview discusses the advantages and drawbacks of universal electronic modules, considering their application in prototyping and manufacture of intelligent analytical instrumentation.
Collapse
Affiliation(s)
- Pawel L Urban
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu 300, Taiwan
| |
Collapse
|
22
|
Hu JB, Chen TR, Chang CH, Cheng JY, Chen YC, Urban PL. A compact 3D-printed interface for coupling open digital microchips with Venturi easy ambient sonic-spray ionization mass spectrometry. Analyst 2015; 140:1495-501. [PMID: 25622965 DOI: 10.1039/c4an02220c] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Digital microfluidics (DMF) based on the electrowetting-on-dielectric phenomenon is a convenient way of handling microlitre-volume aliquots of solutions prior to analysis. Although it was shown to be compatible with on-line mass spectrometric detection, due to numerous technical obstacles, the implementation of DMF in conjunction with MS is still beyond the reach of many analytical laboratories. Here we present a facile method for coupling open DMF microchips to mass spectrometers using Venturi easy ambient sonic-spray ionization operated at atmospheric pressure. The proposed interface comprises a 3D-printed body that can easily be "clipped" at the inlet of a standard mass spectrometer. The accessory features all the necessary connections for an open-architecture DMF microchip with T-shaped electrode arrangement, thermostatting of the microchip, purification of air (to prevent accidental contamination of the microchip), a Venturi pump, and two microfluidic pumps to facilitate transfer of samples and reagents onto the microchip. The system also incorporates a touch-screen panel and remote control for user-friendly operation. It is based on the use of popular open-source electronic modules, and can readily be assembled at low expense.
Collapse
Affiliation(s)
- Jie-Bi Hu
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu 300, Taiwan.
| | | | | | | | | | | |
Collapse
|