• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4595689)   Today's Articles (1805)   Subscriber (49333)
For: Allaire P, Hilton E, Baloh M, Maslen E, Bearnson G, Noh D, Khanwilkar P, Olsen D. Performance of a continuous flow ventricular assist device: magnetic bearing design, construction, and testing. Artif Organs 1998;22:475-80. [PMID: 9650668 DOI: 10.1046/j.1525-1594.1998.06095.x] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Number Cited by Other Article(s)
1
Performance Enhancement of a Magnetic System in a Ultra Compact 5-DOF-Controlled Self-Bearing Motor for a Rotary Pediatric Ventricular-Assist Device to Diminish Energy Input. ACTUATORS 2019. [DOI: 10.3390/act8020031] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
2
Wood H, Anderson J, Allaire P, Mcdaniel J, Bearnson G. Numerical Solution for Blood Flow in a Centrifugal Ventricular Assist Device. Int J Artif Organs 2018. [DOI: 10.1177/039139889902201209] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
3
Cheng S, Olles MW, Burger AF, Day SW. Optimization of a Hybrid Magnetic Bearing for a Magnetically Levitated Blood Pump via 3-D FEA. MECHATRONICS : THE SCIENCE OF INTELLIGENT MACHINES 2011;21:1163-1169. [PMID: 22065892 PMCID: PMC3208351 DOI: 10.1016/j.mechatronics.2011.07.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
4
Lim TM, Cheng S, Chua LP. Parameter Estimation and Actuator Characteristics of Hybrid Magnetic Bearings for Axial Flow Blood Pump Applications. Artif Organs 2009;33:509-31. [DOI: 10.1111/j.1525-1594.2009.00732.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
5
Throckmorton AL, Untaroiu A, Lim DS, Wood HG, Allaire PE. Fluid force predictions and experimental measurements for a magnetically levitated pediatric ventricular assist device. Artif Organs 2007;31:359-68. [PMID: 17470205 DOI: 10.1111/j.1525-1594.2007.00393.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
6
Asama J, Shinshi T, Hoshi H, Takatani S, Shimokohbe A. A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller. Artif Organs 2006;30:160-7. [PMID: 16480390 DOI: 10.1111/j.1525-1594.2006.00202.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
7
Throckmorton AL, Lim DS, McCulloch MA, Jiang W, Song X, Allaire PE, Wood HG, Olsen DB. Computational Design and Experimental Performance Testing of an Axial-Flow Pediatric Ventricular Assist Device. ASAIO J 2005;51:629-35. [PMID: 16322729 DOI: 10.1097/01.mat.0000177541.53513.a8] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
8
Onuma H, Murakami M, Masuzawa T. Novel maglev pump with a combined magnetic bearing. ASAIO J 2005;51:50-5. [PMID: 15745134 DOI: 10.1097/01.mat.0000151149.23519.19] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
9
Song X, Untaroiu A, Wood HG, Allaire PE, Throckmorton AL, Day SW, Olsen DB. Design and transient computational fluid dynamics study of a continuous axial flow ventricular assist device. ASAIO J 2004;50:215-24. [PMID: 15171472 DOI: 10.1097/01.mat.0000124954.69612.83] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
10
Chung MKH, Zhang N, Tansley GD, Qian Y. Experimental Determination of Dynamic Characteristics of the VentrAssist Implantable Rotary Blood Pump. Artif Organs 2004;28:1089-94. [PMID: 15554937 DOI: 10.1111/j.1525-1594.2004.07348.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
11
Throckmorton AL, Untaroiu A, Allaire PE, Wood HG, Matherne GP, Lim DS, Peeler BB, Olsen DB. Computational Analysis of an Axial Flow Pediatric Ventricular Assist Device. Artif Organs 2004. [DOI: 10.1111/j.1525-1594.2004.00009_1.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
12
Locke DH, Swanson ES, Walton JF, Willis JP, Heshmat H. Testing of a centrifugal blood pump with a high efficiency hybrid magnetic bearing. ASAIO J 2004;49:737-43. [PMID: 14655745 DOI: 10.1097/01.mat.0000093963.64669.96] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]  Open
13
Chung MKH, Zhang N, Tansley GD, Woodard JC. Impeller Behavior and Displacement of the VentrAssist Implantable Rotary Blood Pump. Artif Organs 2004;28:287-97. [PMID: 15046628 DOI: 10.1111/j.1525-1594.2004.47269.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
14
Masuzawa T, Ezoe S, Kato T, Okada Y. Magnetically suspended centrifugal blood pump with an axially levitated motor. Artif Organs 2003;27:631-8. [PMID: 12823418 DOI: 10.1046/j.1525-1594.2003.07111.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
15
Masuzawa T, Onuma H, Kim SJ, Okada Y. Magnetically suspended centrifugal blood pump with a self bearing motor. ASAIO J 2002;48:437-42. [PMID: 12141477 DOI: 10.1097/00002480-200207000-00019] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
16
Masuzawa T, Kita T, Okada Y. An ultradurable and compact rotary blood pump with a magnetically suspended impeller in the radial direction. Artif Organs 2001;25:395-9. [PMID: 11403671 DOI: 10.1046/j.1525-1594.2001.025005395.x] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
17
Koerner MM, Loebe M, Lisman KA, Stetson SJ, Lafuente JA, Noon GP, Torre-Amione G. New strategies for the management of acute decompensated heart failure. Curr Opin Cardiol 2001;16:164-73. [PMID: 11357011 DOI: 10.1097/00001573-200105000-00002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
18
Masuzawa T, Kita T, Matsuda K, Okada Y. Magnetically suspended rotary blood pump with radial type combined motor-bearing. Artif Organs 2000;24:468-74. [PMID: 10886067 DOI: 10.1046/j.1525-1594.2000.06577.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
19
Vidakovic S, Ayre P, Woodard J, Lingard N, Tansley G, Reizes J. Paradoxical effects of viscosity on the VentrAssist rotary blood pump. Artif Organs 2000;24:478-82. [PMID: 10886069 DOI: 10.1046/j.1525-1594.2000.06600.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
20
Baloh MJ, Allaire PE, Hilton EF, Wei N, Olsen DB, Bearnson GB, Khanwilkar PS. Characterization of a magnetic bearing system and fluid properties for a continuous flow ventricular assist device. Artif Organs 1999;23:792-6. [PMID: 10463509 DOI: 10.1046/j.1525-1594.1999.06425.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
PrevPage 1 of 1 1Next