1
|
Updated S2k Clinical Practice Guideline on Non-alcoholic Fatty Liver Disease (NAFLD) issued by the German Society of Gastroenterology, Digestive and Metabolic Diseases (DGVS) - April 2022 - AWMF Registration No.: 021-025. ZEITSCHRIFT FUR GASTROENTEROLOGIE 2022; 60:e733-e801. [PMID: 36100201 DOI: 10.1055/a-1880-2388] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
|
2
|
Roeb E, Canbay A, Bantel H, Bojunga J, de Laffolie J, Demir M, Denzer UW, Geier A, Hofmann WP, Hudert C, Karlas T, Krawczyk M, Longerich T, Luedde T, Roden M, Schattenberg J, Sterneck M, Tannapfel A, Lorenz P, Tacke F. Aktualisierte S2k-Leitlinie nicht-alkoholische Fettlebererkrankung der Deutschen Gesellschaft für Gastroenterologie, Verdauungs- und Stoffwechselkrankheiten (DGVS) – April 2022 – AWMF-Registernummer: 021–025. ZEITSCHRIFT FUR GASTROENTEROLOGIE 2022; 60:1346-1421. [PMID: 36100202 DOI: 10.1055/a-1880-2283] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- E Roeb
- Gastroenterologie, Medizinische Klinik II, Universitätsklinikum Gießen und Marburg, Gießen, Deutschland
| | - A Canbay
- Medizinische Klinik, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Deutschland
| | - H Bantel
- Klinik für Gastroenterologie, Hepatologie und Endokrinologie, Medizinische Hochschule Hannover (MHH), Hannover, Deutschland
| | - J Bojunga
- Medizinische Klinik I Gastroent., Hepat., Pneum., Endokrin., Universitätsklinikum Frankfurt, Frankfurt, Deutschland
| | - J de Laffolie
- Allgemeinpädiatrie und Neonatologie, Zentrum für Kinderheilkunde und Jugendmedizin, Universitätsklinikum Gießen und Marburg, Gießen, Deutschland
| | - M Demir
- Medizinische Klinik mit Schwerpunkt Hepatologie und Gastroenterologie, Charité - Universitätsmedizin Berlin, Campus Virchow-Klinikum und Campus Charité Mitte, Berlin, Deutschland
| | - U W Denzer
- Klinik für Gastroenterologie und Endokrinologie, Universitätsklinikum Gießen und Marburg, Marburg, Deutschland
| | - A Geier
- Medizinische Klinik und Poliklinik II, Schwerpunkt Hepatologie, Universitätsklinikum Würzburg, Würzburg, Deutschland
| | - W P Hofmann
- Gastroenterologie am Bayerischen Platz - Medizinisches Versorgungszentrum, Berlin, Deutschland
| | - C Hudert
- Klinik für Pädiatrie m. S. Gastroenterologie, Nephrologie und Stoffwechselmedizin, Charité Campus Virchow-Klinikum - Universitätsmedizin Berlin, Berlin, Deutschland
| | - T Karlas
- Klinik und Poliklinik für Onkologie, Gastroenterologie, Hepatologie, Pneumologie und Infektiologie, Universitätsklinikum Leipzig, Leipzig, Deutschland
| | - M Krawczyk
- Klinik für Innere Medizin II, Gastroent., Hepat., Endokrin., Diabet., Ern.med., Universitätsklinikum des Saarlandes, Homburg, Deutschland
| | - T Longerich
- Pathologisches Institut, Universitätsklinikum Heidelberg, Heidelberg, Deutschland
| | - T Luedde
- Klinik für Gastroenterologie, Hepatologie und Infektiologie, Universitätsklinikum Düsseldorf, Düsseldorf, Deutschland
| | - M Roden
- Klinik für Endokrinologie und Diabetologie, Universitätsklinikum Düsseldorf, Düsseldorf, Deutschland
| | - J Schattenberg
- I. Medizinische Klinik und Poliklinik, Universitätsmedizin Mainz, Mainz, Deutschland
| | - M Sterneck
- Klinik für Hepatobiliäre Chirurgie und Transplantationschirurgie, Universitätsklinikum Hamburg, Hamburg, Deutschland
| | - A Tannapfel
- Institut für Pathologie, Ruhr-Universität Bochum, Bochum, Deutschland
| | - P Lorenz
- Deutsche Gesellschaft für Gastroenterologie, Verdauungs- und Stoffwechselkrankheiten (DGVS), Berlin, Deutschland
| | - F Tacke
- Medizinische Klinik mit Schwerpunkt Hepatologie und Gastroenterologie, Charité - Universitätsmedizin Berlin, Campus Virchow-Klinikum und Campus Charité Mitte, Berlin, Deutschland
| | | |
Collapse
|
3
|
Li Y, Ma J, Li B, Zhu X, Wang J. Cirrhosis of Wilson's disease: High and low cutoff using acoustic radiation force impulse (ARFI) -Comparison and combination with serum fibrosis index. Clin Hemorheol Microcirc 2021; 79:575-585. [PMID: 34334385 DOI: 10.3233/ch-211219] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Acoustic Radiation Force Impulse (ARFI), Fibrosis-4(FIB-4) and Aspartate transaminase to platelet ratio index (APRI) are valuable non-invasive methods to evaluate fibrosis in hepatitis virus. Yet, they are rarely used in Wilson's disease. OBJECTIVE Evaluate the diagnostic efficacy of ARFI, FIB-4, APRI, combined detection in cirrhosis with WD, and speculate the optimal high, low cutoff. METHODS This retrospective study was authorized by hospital ethics Committee (number:2021MCZQ02). 102 patients with WD completed ARFI and laboratory examination on the same day. The intraclass correlation coeffcient (ICC) of ARFI among three sonographers was 0.896 (95%CI:0.859-0.925, p = 0.000). The stage of liver involvement was classified into 5 categories according to clinical manifestations, laboratory examination, and liver morphologic characteristics: I, normal; II, biochemical abnormal only; III, abnormal liver morphologic features without sighs of cirrhosis; IV, clinical and imaging sighs of compensateded cirrhosis (Child-Pugh A); V, decompensated cirrhosis (Child-Pugh B and C). This stage system served as the reference standard. The diagnostic efficacy was analyzed by Logistic regression, ROC curve. The optimal low cut-off with high sensitivity (SE) and low negative likelihood ratio (NLR) and high cut-off with high specificity (SP) and positive likelihood ratio (PLR) were derived. RESULTS The diagnostic value of ARFI (0.85, 95%CI:0.77-0.92, p = 0.000) in distiguishing cirrhosis with WD was higher than FIB-4 (0.59, 95%CI: 0.47-0.70, p = 0.127), APRI (0.70, 95%CI: 0.59-0.81, p = 0.000). The low, high cut-off of ARFI for excluding, diagnosing cirrhosis with WD was 1.47 m/s(SE: 98%, NLR:0.09), 2.11 m/s(SP:98%, PLR:27.4), 37 (36%) patients could be spared a liver biopsy. When ARFI was 1.47∼2.11 m/s, liver biopsy was recommended. After combined with ARFI, the AUROC of FIB-4, APRI were increased respectively (p < 0.001), there were not different between ARFI and combined detection(p > 0.05). CONCLUSION ARFI could replace some unnecessary liver biopsy according to high diagnostic efficacy for identifying cirrhosis of WD. The combined detection can also be used as an important model to predict cirrhosis in WD.
Collapse
Affiliation(s)
- Yan Li
- Department of Intervention, The First Affiliated Hospital of Soochow University, Jiangsu, China
| | - Jianbing Ma
- Department of Radiology, the First Hospital of Jiaxing, The Affiliated Hospital of Jiaxing University, Zhejiang, China
| | - Baoqi Li
- Department of Ultrasound, The First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Anhui, China
| | - Xiaoli Zhu
- Department of Intervention, The First Affiliated Hospital of Soochow University, Jiangsu, China
| | - Jingping Wang
- Department of Ultrasound, The First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Anhui, China
| |
Collapse
|
4
|
Yoshino K, Taura K, Okuda Y, Ikeno Y, Uemoto Y, Nishio T, Yamamoto G, Tanabe K, Koyama Y, Seo S, Kaido T, Okajima H, Imai T, Tanaka S, Uemoto S. Efficiency of acoustic radiation force impulse imaging for the staging of graft fibrosis after liver transplantation. Hepatol Res 2019; 49:394-403. [PMID: 30471140 DOI: 10.1111/hepr.13289] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Revised: 11/15/2018] [Accepted: 11/19/2018] [Indexed: 02/07/2023]
Abstract
AIM Liver biopsy is the gold standard for assessing liver fibrosis (LF) after liver transplantation (LT), but its invasiveness limits its utility. This study aimed to evaluate the usefulness of liver stiffness measurement (LSM) using acoustic radiation force impulse (ARFI) imaging to assess LF after LT. METHODS Between September 2013 and January 2017, 278 patients who underwent liver biopsy after LT in Kyoto University Hospital (Kyoto, Japan) were prospectively enrolled. Liver stiffness measurement was carried out using ARFI imaging; its value was expressed as shear wave velocity (Vs) [m/s]. The LF was evaluated according to METAVIR score (F0-F4). The diagnostic performance of Vs for F2≤ and F3≤ was assessed and compared with that of laboratory tests using receiver operating characteristic (ROC) analysis. RESULTS The median Vs values increased according to the progression of LF (F0, 1.18 (0.78-1.92); F1, 1.35 (0.72-3.54); F2, 1.55 (1.05-3.37); F3, 1.84 (1.41-2.97)). The Vs had the highest area under the ROC curve (AUROC) for the prediction of both F2 ≤ and F3 ≤ fibrosis (F2, 0.77; and F3, 0.85). With the cut-off value of Vs >1.31, sensitivity, specificity, positive predictive value, and negative predictive value were 89.4%, 53.3%, 37.3%, and 94.2% in predicting F2≤, respectively. Shear wave velocity diagnosed LF better than any laboratory tests regardless of the type of primary disease. CONCLUSIONS Acoustic radiation force impulse helps to assess graft LF after LT. The high sensitivity suggested that ARFI might reduce the frequency of liver biopsies by detecting patients who are unlikely to have significant fibrosis after LT. (Unique trial no. UMIN R000028296.).
Collapse
Affiliation(s)
- Kenji Yoshino
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Kojiro Taura
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Yukihiro Okuda
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Yoshinobu Ikeno
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Yusuke Uemoto
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Takahiro Nishio
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Gen Yamamoto
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Kazutaka Tanabe
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Yukinori Koyama
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Satoru Seo
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Toshimi Kaido
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Hideaki Okajima
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| | - Takumi Imai
- Department of Clinical Biostatistics/Clinical Biostatistics Course, Kyoto University Graduate School of Medicine and Public Health, Kyoto, Japan
| | - Shiro Tanaka
- Department of Clinical Biostatistics/Clinical Biostatistics Course, Kyoto University Graduate School of Medicine and Public Health, Kyoto, Japan
| | - Shinji Uemoto
- Department of Surgery, Graduate School of Medicine Kyoto University, Kyoto, Japan
| |
Collapse
|
5
|
Byenfeldt M, Elvin A, Fransson P. Influence of Probe Pressure on Ultrasound-Based Shear Wave Elastography of the Liver Using Comb-Push 2-D Technology. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:411-428. [PMID: 30401508 DOI: 10.1016/j.ultrasmedbio.2018.09.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 09/25/2018] [Accepted: 09/26/2018] [Indexed: 06/08/2023]
Abstract
It has been postulated that in the liver, applying increased probe pressure during ultrasound-based shear wave elastography (SWE) might lead to a false increase in the SWE result. We aimed to determine the influence of increased intercostal probe pressure when performing SWE of the liver. We also investigated the number of measurements required to achieve technically successful and reliable SWE examinations. This prospective, clinical study included 112 patients and 2240 SWE measurements of the liver. We applied probe pressure intercostally, to reduce the skin-to-liver capsule distance (SCD), which could stabilize the SWE signal and thus increase the number of technically successful measurements. We performed 10 measurements with maximum probe pressure and 10 with normal pressure in each patient. Thus, two analysis groups were compared for differences. Compared with normal pressure, maximum probe pressure significantly reduced the SCD (p < 0.001) and significantly increased the number of technically successful measurements from 981 to 1098, respectively (p < 0.001). The SWE results with normal and maximum probe pressure were 5.96 kPa (interquartile range: 2.41) and 5.45 kPa (interquartile range: 1.96), respectively (p < 0.001). In obese patients, a large SCD poses a diagnostic challenge for ultrasound SWE. We found that maximum intercostal probe pressure could reduce the SCD and increase the number of technically successful measurements, without falsely increasing the SWE result. Only three measurements were required to achieve technically successful and reliable SWE examinations.
Collapse
Affiliation(s)
| | - Anders Elvin
- Department of Molecular Medicine and Surgery, Karolinska Institute, Karolinska University Hospital, Stockholm, Sweden
| | - Per Fransson
- Department of Nursing, Umeå University, Umeå, Sweden
| |
Collapse
|
6
|
Goertz RS, GaBmann L, Strobel D, Wildner D, Schellhaas B, Neurath MF, Pfeifer L. Acoustic Radiation Force Impulse (ARFI) Elastography in Autoimmune and Cholestatic Liver Diseases. Ann Hepatol 2019; 18:23-29. [PMID: 31113596 DOI: 10.5604/01.3001.0012.7858] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Accepted: 07/17/2017] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Acoustic Radiation Force Impulse (ARFI) elastography evaluates hepatic fibrosis non-invasively and has been mainly validated in viral hepatitis. Data on rare liver diseases such as autoimmune hepatitis (AIH), overlap syndrome, primary biliary cholangitis (PBC) or primary sclerosing cholangitis (PSC) are sparse. MATERIAL AND METHODS 85 patients (including 31 AIH, 26 PBC, 16 PSC and 3 PSC-and 9 PBC-AIH-overlap syndromes) were retrospectively analysed pointing at ARFI elastography of the liver and the correlation with histologic Ishak fibrosis score (F0-6). Results of shear wave velocities (m/s) were expressed as mean ± standard deviation. RESULTS The mean shear wave velocity of all 85 patients showed 1.80 ± 0.84 m/s (0.74-3.98). The ARFI elastography values correlated with the degree of fibrosis in all patients overall and in patients with AIH, overlap syndrome and PSC, respectively. The subgroup of 26 patients with PBC (only with Ishak F > 3) revealed no correlation between ARFI and these early fibrosis stages (r = 0.019, p = 0.927). ARFI elastography correlated with bilirubin, AST, but not with patient age, body mass index or measurement depth. The cut-off of 2.04 m/s for detecting cirrhosis (Ishak F > 5) leads to a sensitivity of 90.0% and specificity of 74.7% (AUROC 87.2%). CONCLUSION ARFI elastography can evaluate fibrosis in AIH, PSC and PSC-/PBC-AIH-overlap syndrome with good accuracy for the detection of hepatic cirrhosis. Shear wave velocities in PBC should be interpreted with caution in early stages of fibrosis.
Collapse
Affiliation(s)
- Ruediger S Goertz
- Department of Internal Medicine 1, Friedrich-Alexander University Erlangen-Nurnberg, Erlangen, Germany.
| | - Luise GaBmann
- Department of Internal Medicine 1, Friedrich-Alexander University Erlangen-Nurnberg, Erlangen, Germany
| | - Deike Strobel
- Department of Internal Medicine 1, Friedrich-Alexander University Erlangen-Nurnberg, Erlangen, Germany
| | - Dane Wildner
- Department of Internal Medicine 1, Friedrich-Alexander University Erlangen-Nurnberg, Erlangen, Germany
| | - Barbara Schellhaas
- Department of Internal Medicine 1, Friedrich-Alexander University Erlangen-Nurnberg, Erlangen, Germany
| | - Markus F Neurath
- Department of Internal Medicine 1, Friedrich-Alexander University Erlangen-Nurnberg, Erlangen, Germany
| | - Lukas Pfeifer
- Department of Internal Medicine 1, Friedrich-Alexander University Erlangen-Nurnberg, Erlangen, Germany
| |
Collapse
|
7
|
Kim J, Seo A, Kim JY, Choi SH, Yoon HJ, Kim E, Hwang JY. A Multimodal Biomicroscopic System based on High-frequency Acoustic Radiation Force Impulse and Multispectral Imaging Techniques for Tumor Characterization Ex vivo. Sci Rep 2017; 7:17518. [PMID: 29235512 PMCID: PMC5727531 DOI: 10.1038/s41598-017-17367-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 11/24/2017] [Indexed: 12/17/2022] Open
Abstract
We report a multimodal biomicroscopic system which offers high-frequency ultrasound B-mode, acoustic radiation force impulse (ARFI), and multispectral imaging for qualitative tumor characterization ex vivo. Examinations of resected tissues from diseased regions such as tumors are crucial procedures during surgical operations to treat cancer. Particularly, if tiny tumors remain at surgical sites after tumor resection, such tumors can result in unwanted outcomes, such as cancer recurrence or metastasis to other organs. To avoid this, accurate characterizations of tumors resected during surgery are necessary. To this end, we devised a multimodal biomicroscopic system including high-frequency ultrasound B-mode, ARFI, and multispectral imaging modalities to examine resected tumors with high levels of accuracy. This system was evaluated with tissue-mimicking phantoms with different mechanical properties. In addition, colorectal tumors excised from cancer patients were examined. The proposed system offers highly resolved anatomical, mechanical, chemical information pertaining to tumors, thus allowing the detection of tumor regions from the surface to deep inside tissues. These results therefore suggest that the multimodal biomicroscopic system has the potential to undertake qualitative characterizations of excised tumors ex vivo.
Collapse
Affiliation(s)
- Jihun Kim
- Daegu Gyeongbuk Institute of Science & Technology, Department of Information & Communication Engineering, Daegu, 42988, Republic of Korea
| | - Anna Seo
- Kyungpook National University, 3D Convergence Technology Center, Daegu, 41061, Republic of Korea
| | - Jun-Young Kim
- Kyungpook National University Hospital, Department of Orthopedic Surgery, Daegu, 41944, Republic of Korea
| | - Sung Hyouk Choi
- Seoul National University, College of Medicine, Seoul, 03080, Republic of Korea
| | - Hyung-Jin Yoon
- Seoul National University, College of Medicine, Seoul, 03080, Republic of Korea
| | - Eunjoo Kim
- Daegu Gyeongbuk Institute of Science & Technology, Department of Nano & Energy Research, Daegu, 42988, Republic of Korea.
| | - Jae Youn Hwang
- Daegu Gyeongbuk Institute of Science & Technology, Department of Information & Communication Engineering, Daegu, 42988, Republic of Korea.
| |
Collapse
|
8
|
Effect of ultrasound frequency on the Nakagami statistics of human liver tissues. PLoS One 2017; 12:e0181789. [PMID: 28763461 PMCID: PMC5538657 DOI: 10.1371/journal.pone.0181789] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Accepted: 07/07/2017] [Indexed: 12/11/2022] Open
Abstract
The analysis of the backscattered statistics using the Nakagami parameter is an emerging ultrasound technique for assessing hepatic steatosis and fibrosis. Previous studies indicated that the echo amplitude distribution of a normal liver follows the Rayleigh distribution (the Nakagami parameter m is close to 1). However, using different frequencies may change the backscattered statistics of normal livers. This study explored the frequency dependence of the backscattered statistics in human livers and then discussed the sources of ultrasound scattering in the liver. A total of 30 healthy participants were enrolled to undergo a standard care ultrasound examination on the liver, which is a natural model containing diffuse and coherent scatterers. The liver of each volunteer was scanned from the right intercostal view to obtain image raw data at different central frequencies ranging from 2 to 3.5 MHz. Phantoms with diffuse scatterers only were also made to perform ultrasound scanning using the same protocol for comparisons with clinical data. The Nakagami parameter-frequency correlation was evaluated using Pearson correlation analysis. The median and interquartile range of the Nakagami parameter obtained from livers was 1.00 (0.98-1.05) for 2 MHz, 0.93 (0.89-0.98) for 2.3 MHz, 0.87 (0.84-0.92) for 2.5 MHz, 0.82 (0.77-0.88) for 3.3 MHz, and 0.81 (0.76-0.88) for 3.5 MHz. The Nakagami parameter decreased with the increasing central frequency (r = -0.67, p < 0.0001). However, the effect of ultrasound frequency on the statistical distribution of the backscattered envelopes was not found in the phantom results (r = -0.147, p = 0.0727). The current results demonstrated that the backscattered statistics of normal livers is frequency-dependent. Moreover, the coherent scatterers may be the primary factor to dominate the frequency dependence of the backscattered statistics in a liver.
Collapse
|
9
|
Porra L, Swan H, Ho C. The effect of applied transducer force on acoustic radiation force impulse quantification within the left lobe of the liver. Australas J Ultrasound Med 2015; 18:100-106. [PMID: 28191250 PMCID: PMC5024960 DOI: 10.1002/j.2205-0140.2015.tb00208.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Introduction: Acoustic Radiation Force Impulse (ARFI) Quantification measures shear wave velocities (SWVs) within the liver. It is a reliable method for predicting the severity of liver fibrosis and has the potential to assess fibrosis in any part of the liver, but previous research has found ARFI quantification in the right lobe more accurate than in the left lobe. A lack of standardised applied transducer force when performing ARFI quantification in the left lobe of the liver may account for some of this inaccuracy. The research hypothesis of this present study predicted that an increase in applied transducer force would result in an increase in SWVs measured. Methods: ARFI quantification within the left lobe of the liver was performed within a group of healthy volunteers (n = 28). During each examination, each participant was subjected to ARFI quantification at six different levels of transducer force applied to the epigastric abdominal wall. Results: A repeated measures ANOVA test showed that ARFI quantification was significantly affected by applied transducer force (p = 0.002). Significant pairwise comparisons using Bonferroni correction for multiple comparisons showed that with an increase in applied transducer force, there was a decrease in SWVs. Conclusion: Applied transducer force has a significant effect on SWVs within the left lobe of the liver and it may explain some of the less accurate and less reliable results in previous studies where transducer force was not taken into consideration. Future studies in the left lobe of the liver should take this into account and control for applied transducer force.
Collapse
Affiliation(s)
| | - Hans Swan
- School of Dentistry and Health Sciences Charles Sturt University Wagga Wagga New South Wales Australia
| | | |
Collapse
|
10
|
Abstract
Noninvasive, ultrasound-based methods for visualizing and measuring tissue elasticity are becoming more and more common in routine practice. Using hepatic shear wave elastography, cut-off levels can help to detect the degree of relevant fibrosis (F ≥ 2) with a diagnostic accuracy using the area under the reader operating characteristic (AUROC) of 87 % and cirrhosis (F = 4, AUROC 93 %). Normal values virtually exclude liver cirrhosis (negative predictive value up to 97 %) and high shear wave velocities predict complications in the course of primary sclerosing cholangitis, liver cirrhosis and chronic hepatitis B or C. Elastography is of no relevant help in the differentiation of the dignity of hepatic lesions. Concerning thyroid or breast lesions, low shear wave velocities are indicative of benign lesions and in contrast, high velocities of malignant lesions. A differentiation between benign and malignant thyroid nodules is performed by elastography with a sensitivity of 89 % and a specificity of 82 %. In breast lesions a differentiation of nodes can be improved with elastography compared to B-mode ultrasound alone with a sensitivity of 97 % and a specificity of 83 %. Invasive biopsy punctures can therefore be specifically performed or can be omitted. Due to several influencing factors, in particular during liver elastography, the measurements need to be interpreted in the clinical context. In summary, ultrasound-based elastography provides helpful information for the detection of hepatic fibrosis and for further characterization of thyroid or breast lesions in addition to classical techniques, such as B-mode imaging and color Doppler.
Collapse
|