1
|
Ning Z, Chen S, Chen Z, Han H, Qiao H, Zhang N, Wang R, Shen R, Zhao X. Saturated multi-delay renal arterial spin labeling technique for simultaneous perfusion and T 1 quantification in kidneys. Magn Reson Med 2022; 88:1055-1067. [PMID: 35506512 DOI: 10.1002/mrm.29268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 03/22/2022] [Accepted: 03/24/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE To propose a free-breathing simultaneous multi-delay arterial spin labeling (ASL) and T1 mapping technique with a stepwise kinetic model for renal assessment in a single 4-min scan at 3 T. METHODS The proposed saturated multi-delay renal arterial spin labeling (SAMURAI) sequence used flow-sensitive alternating inversion recovery (FAIR) preparation, followed by acquisition of 9 images with Look-Locker spoiled gradient recalled echo (SPGR). Pre-saturation at the imaging slice was used to achieve saturation-based T1 mapping. A 4-step 2-compartment kinetic model was proposed to characterize water transition through artery- and tissue-compartment. The impact of the Look-Locker sampling scheme on the ASL signal was corrected in this model. T1 estimation with dictionary searching method and perfusion quantification based on the proposed kinetic model fitting were conducted after groupwise registration of the acquired images. The feasibility and repeatability of SAMURAI were validated in healthy subjects (n = 11) and patients with different renal diseases (n = 4). RESULTS The proposed SAMURAI technique can provide accurate T1 map with strong correlation (R2 = 0.98) with inversion recovery spin echo (IR-SE) on phantom. SAMURAI provided equally reliable whole kidney and cortical ASL and T1 quantification results compared with multi-TI FAIR (intraclass correlation coefficient [ICC], 0.880-0.958) and IR-SPGR (ICC, 0.875-0.912), respectively. Low renal blood flow and increased T1 were detected by SAMURAI in the affected kidneys of the patients. SAMURAI had excellent scan-rescan repeatability (ICC, 0.905-0.992) and significantly reduced scan time (4 min 6 s vs. 45 min for 9 TIs) compared to multi-TI FAIR. CONCLUSION The proposed SAMURAI technique is feasible and repeatable for simultaneously quantifying T1 and perfusion of kidneys with high time-efficiency.
Collapse
Affiliation(s)
- Zihan Ning
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing, China
| | - Shuo Chen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing, China.,Tsinghua University-Peking University Joint Center for Life Sciences, Beijing, China
| | - Zhensen Chen
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China
| | - Hualu Han
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing, China
| | - Huiyu Qiao
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing, China.,Tsinghua University-Peking University Joint Center for Life Sciences, Beijing, China
| | - Nan Zhang
- Department of Radiology, Beijing Anzhen Hospital, Beijing, China
| | - Rui Wang
- Department of Radiology, Peking University First Hospital, Beijing, China
| | - Rui Shen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing, China
| | - Xihai Zhao
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing, China
| |
Collapse
|
2
|
Eckerbom P, Hansell P, Cox E, Buchanan C, Weis J, Palm F, Francis S, Liss P. Circadian variation in renal blood flow and kidney function in healthy volunteers monitored with noninvasive magnetic resonance imaging. Am J Physiol Renal Physiol 2020; 319:F966-F978. [PMID: 33073586 DOI: 10.1152/ajprenal.00311.2020] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Circadian regulation of kidney function is involved in maintaining whole body homeostasis, and dysfunctional circadian rhythm can potentially be involved in disease development. Magnetic resonance imaging (MRI) provides reliable and reproducible repetitive estimates of kidney function noninvasively without the risk of adverse events associated with contrast agents and ionizing radiation. The purpose of this study was to estimate circadian variations in kidney function in healthy human subjects with MRI and to relate the findings to urinary excretions of electrolytes and markers of kidney function. Phase-contrast imaging, arterial spin labeling, and blood oxygen level-dependent transverse relaxation rate (R2*) mapping were used to assess total renal blood flow and regional perfusion as well as intrarenal oxygenation in eight female and eight male healthy volunteers every fourth hour during a 24-h period. Parallel with MRI scans, standard urinary and plasma parameters were quantified. Significant circadian variations of total renal blood flow were found over 24 h, with increasing flow from noon to midnight and decreasing flow during the night. In contrast, no circadian variation in intrarenal oxygenation was detected. Urinary excretions of electrolytes, osmotically active particles, creatinine, and urea all displayed circadian variations, peaking during the afternoon and evening hours. In conclusion, total renal blood flow and kidney function, as estimated from excretion of electrolytes and waste products, display profound circadian variations, whereas intrarenal oxygenation displays significantly less circadian variation.
Collapse
Affiliation(s)
- Per Eckerbom
- Section of Radiology, Department of Surgical Sciences, University Hospital, Uppsala, Sweden
| | - Peter Hansell
- Department of Medical Cell Biology, Uppsala University, Uppsala, Sweden
| | - Eleanor Cox
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, United Kingdom
| | - Charlotte Buchanan
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, United Kingdom
| | - Jan Weis
- Department of Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| | - Fredrik Palm
- Department of Medical Cell Biology, Uppsala University, Uppsala, Sweden
| | - Susan Francis
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, United Kingdom
| | - Per Liss
- Section of Radiology, Department of Surgical Sciences, University Hospital, Uppsala, Sweden
| |
Collapse
|
3
|
Nery F, Buchanan CE, Harteveld AA, Odudu A, Bane O, Cox EF, Derlin K, Gach HM, Golay X, Gutberlet M, Laustsen C, Ljimani A, Madhuranthakam AJ, Pedrosa I, Prasad PV, Robson PM, Sharma K, Sourbron S, Taso M, Thomas DL, Wang DJJ, Zhang JL, Alsop DC, Fain SB, Francis ST, Fernández-Seara MA. Consensus-based technical recommendations for clinical translation of renal ASL MRI. MAGMA (NEW YORK, N.Y.) 2019. [PMID: 31833014 DOI: 10.1007/s10334‐019‐00800‐z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVES This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T field strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. METHODS An international panel of 23 renal ASL experts followed a modified Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. RESULTS Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or flow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantification model. DISCUSSION This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding.
Collapse
Affiliation(s)
- Fabio Nery
- Developmental Imaging and Biophysics Section, UCL Great Ormond Street Institute of Child Health, London, UK
| | - Charlotte E Buchanan
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | - Anita A Harteveld
- Department of Radiology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Aghogho Odudu
- Division of Cardiovascular Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Octavia Bane
- Translational and Molecular Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Eleanor F Cox
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | - Katja Derlin
- Department of Radiology, Hannover Medical School, Hannover, Germany
| | - H Michael Gach
- Departments of Radiation Oncology, Radiology, and Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Xavier Golay
- Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Marcel Gutberlet
- Department of Radiology, Hannover Medical School, Hannover, Germany
| | - Christoffer Laustsen
- MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Ananth J Madhuranthakam
- Department of Radiology and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - Ivan Pedrosa
- Department of Radiology and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - Pottumarthi V Prasad
- Department of Radiology, Center for Advanced Imaging, NorthShore University Health System, Evanston, IL, USA
| | - Philip M Robson
- Translational and Molecular Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Kanishka Sharma
- Imaging Biomarkers Group, Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK
| | - Steven Sourbron
- Imaging Biomarkers Group, Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK
| | - Manuel Taso
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - David L Thomas
- Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Danny J J Wang
- Stevens Neuroimaging and Informatics Institute, University of Southern California, Los Angeles, CA, USA
| | - Jeff L Zhang
- A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - David C Alsop
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Sean B Fain
- Departments of Medical Physics, Radiology, and Biomedical Engineering, University of Wisconsin, Madison, Madison, USA
| | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | | |
Collapse
|
4
|
Nery F, Buchanan CE, Harteveld AA, Odudu A, Bane O, Cox EF, Derlin K, Gach HM, Golay X, Gutberlet M, Laustsen C, Ljimani A, Madhuranthakam AJ, Pedrosa I, Prasad PV, Robson PM, Sharma K, Sourbron S, Taso M, Thomas DL, Wang DJJ, Zhang JL, Alsop DC, Fain SB, Francis ST, Fernández-Seara MA. Consensus-based technical recommendations for clinical translation of renal ASL MRI. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2019; 33:141-161. [PMID: 31833014 PMCID: PMC7021752 DOI: 10.1007/s10334-019-00800-z] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 11/08/2019] [Accepted: 11/11/2019] [Indexed: 12/14/2022]
Abstract
Objectives This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T field strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. Methods An international panel of 23 renal ASL experts followed a modified Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. Results Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or flow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantification model. Discussion This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding. Electronic supplementary material The online version of this article (10.1007/s10334-019-00800-z) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Fabio Nery
- Developmental Imaging and Biophysics Section, UCL Great Ormond Street Institute of Child Health, London, UK
| | - Charlotte E Buchanan
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | - Anita A Harteveld
- Department of Radiology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Aghogho Odudu
- Division of Cardiovascular Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Octavia Bane
- Translational and Molecular Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Eleanor F Cox
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | - Katja Derlin
- Department of Radiology, Hannover Medical School, Hannover, Germany
| | - H Michael Gach
- Departments of Radiation Oncology, Radiology, and Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Xavier Golay
- Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Marcel Gutberlet
- Department of Radiology, Hannover Medical School, Hannover, Germany
| | - Christoffer Laustsen
- MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - Ananth J Madhuranthakam
- Department of Radiology and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - Ivan Pedrosa
- Department of Radiology and Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - Pottumarthi V Prasad
- Department of Radiology, Center for Advanced Imaging, NorthShore University Health System, Evanston, IL, USA
| | - Philip M Robson
- Translational and Molecular Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Kanishka Sharma
- Imaging Biomarkers Group, Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK
| | - Steven Sourbron
- Imaging Biomarkers Group, Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK
| | - Manuel Taso
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - David L Thomas
- Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Danny J J Wang
- Stevens Neuroimaging and Informatics Institute, University of Southern California, Los Angeles, CA, USA
| | - Jeff L Zhang
- A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - David C Alsop
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - Sean B Fain
- Departments of Medical Physics, Radiology, and Biomedical Engineering, University of Wisconsin, Madison, Madison, USA
| | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | | |
Collapse
|
5
|
Eckerbom P, Hansell P, Cox E, Buchanan C, Weis J, Palm F, Francis S, Liss P. Multiparametric assessment of renal physiology in healthy volunteers using noninvasive magnetic resonance imaging. Am J Physiol Renal Physiol 2019; 316:F693-F702. [PMID: 30648907 DOI: 10.1152/ajprenal.00486.2018] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Noninvasive methods of magnetic resonance imaging (MRI) can quantify parameters of kidney function. The main purpose of this study was to determine baseline values of such parameters in healthy volunteers. In 28 healthy volunteers (15 women and 13 men), arterial spin labeling to estimate regional renal perfusion, blood oxygen level-dependent transverse relaxation rate (R2*) to estimate oxygenation, and apparent diffusion coefficient (ADC), true diffusion (D), and longitudinal relaxation time (T1) to estimate tissue properties were determined bilaterally in the cortex and outer and inner medulla. Additionally, phase-contrast MRI was applied in the renal arteries to quantify total renal blood flow. The results demonstrated profound gradients of perfusion, ADC, and D with highest values in the kidney cortex and a decrease towards the inner medulla. R2* and T1 were lowest in kidney cortex and increased towards the inner medulla. Total renal blood flow correlated with body surface area, body mass index, and renal volume. Similar patterns in all investigated parameters were observed in women and men. In conclusion, noninvasive MRI provides useful tools to evaluate intrarenal differences in blood flow, perfusion, diffusion, oxygenation, and structural properties of the kidney tissue. As such, this experimental approach has the potential to advance our present understanding regarding normal physiology and the pathological processes associated with acute and chronic kidney disease.
Collapse
Affiliation(s)
- Per Eckerbom
- Section of Radiology, Department of Surgical Sciences, University Hospital , Uppsala , Sweden
| | - Peter Hansell
- Section of Integrative Physiology, Department of Medical Cell Biology, Uppsala University , Uppsala , Sweden
| | - Eleanor Cox
- Sir Peter Mansfield Imaging Centre, University of Nottingham , Nottingham , United Kingdom
| | - Charlotte Buchanan
- Sir Peter Mansfield Imaging Centre, University of Nottingham , Nottingham , United Kingdom
| | - Jan Weis
- Department of Medical Physics, University Hospital , Uppsala , Sweden
| | - Fredrik Palm
- Section of Integrative Physiology, Department of Medical Cell Biology, Uppsala University , Uppsala , Sweden
| | - Susan Francis
- Sir Peter Mansfield Imaging Centre, University of Nottingham , Nottingham , United Kingdom
| | - Per Liss
- Section of Radiology, Department of Surgical Sciences, University Hospital , Uppsala , Sweden
| |
Collapse
|
6
|
Odudu A, Nery F, Harteveld AA, Evans RG, Pendse D, Buchanan CE, Francis ST, Fernández-Seara MA. Arterial spin labelling MRI to measure renal perfusion: a systematic review and statement paper. Nephrol Dial Transplant 2018; 33:ii15-ii21. [PMID: 30137581 PMCID: PMC6106644 DOI: 10.1093/ndt/gfy180] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Accepted: 05/15/2018] [Indexed: 01/03/2023] Open
Abstract
Renal perfusion provides the driving pressure for glomerular filtration and delivers the oxygen and nutrients to fuel solute reabsorption. Renal ischaemia is a major mechanism in acute kidney injury and may promote the progression of chronic kidney disease. Thus, quantifying renal tissue perfusion is critically important for both clinicians and physiologists. Current reference techniques for assessing renal tissue perfusion have significant limitations. Arterial spin labelling (ASL) is a magnetic resonance imaging (MRI) technique that uses magnetic labelling of water in arterial blood as an endogenous tracer to generate maps of absolute regional perfusion without requiring exogenous contrast. The technique holds enormous potential for clinical use but remains restricted to research settings. This statement paper from the PARENCHIMA network briefly outlines the ASL technique and reviews renal perfusion data in 53 studies published in English through January 2018. Renal perfusion by ASL has been validated against reference methods and has good reproducibility. Renal perfusion by ASL reduces with age and excretory function. Technical advancements mean that a renal ASL study can acquire a whole kidney perfusion measurement in less than 5-10 min. The short acquisition time permits combination with other MRI techniques that might inform drug mechanisms and renal physiology. The flexibility of renal ASL has yielded several variants of the technique, but there are limited data comparing these approaches. We make recommendations for acquiring and reporting renal ASL data and outline the knowledge gaps that future research should address.
Collapse
Affiliation(s)
- Aghogho Odudu
- Division of Cardiovascular Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Fabio Nery
- Developmental Imaging & Biophysics Section, University College London, Great Ormond Street Institute of Child Health, London, UK
| | - Anita A Harteveld
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Roger G Evans
- Department of Physiology, Cardiovascular Disease Program, Biomedicine Discovery Institute, Monash University, Melbourne, Victoria, Australia
| | - Douglas Pendse
- Centre for Medical Imaging, University College London, London, UK
| | - Charlotte E Buchanan
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | | |
Collapse
|
7
|
Non-Invasive Renal Perfusion Imaging Using Arterial Spin Labeling MRI: Challenges and Opportunities. Diagnostics (Basel) 2018; 8:diagnostics8010002. [PMID: 29303965 PMCID: PMC5871985 DOI: 10.3390/diagnostics8010002] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Revised: 12/25/2017] [Accepted: 01/02/2018] [Indexed: 12/28/2022] Open
Abstract
Tissue perfusion allows for delivery of oxygen and nutrients to tissues, and in the kidneys is also a key determinant of glomerular filtration. Quantification of regional renal perfusion provides a potential window into renal (patho) physiology. However, non-invasive, practical, and robust methods to measure renal perfusion remain elusive, particularly in the clinic. Arterial spin labeling (ASL), a magnetic resonance imaging (MRI) technique, is arguably the only available method with potential to meet all these needs. Recent developments suggest its viability for clinical application. This review addresses several of these developments and discusses remaining challenges with the emphasis on renal imaging in human subjects.
Collapse
|
8
|
Schawkat K, Ith M, Christe A, Kühn W, Chittazhathu Y, Bains L, Runge VM, Heverhagen JT. Dynamic non-invasive ASL perfusion imaging of a normal pancreas with secretin augmented MR imaging. Eur Radiol 2018; 28:2389-2396. [PMID: 29302785 DOI: 10.1007/s00330-017-5227-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 11/23/2017] [Accepted: 11/30/2017] [Indexed: 02/07/2023]
Abstract
OBJECTIVES To investigate prospectively the repeatability of pancreatic perfusion measurements using arterial spin labelling (ASL) and to determine the increase in perfusion due to secretin stimulation. MATERIAL AND METHODS An (FAIR)-TrueFISP ASL sequence was applied to determine the perfusion of the pancreatic head in a 3T MRI scanner. Ten healthy volunteers (four men, six women: mean age 28.5 ± 4.6 years; age range 25-40 years) were investigated twice within 1 week. The inter-individual variability was calculated using the standard deviation. Intra-individual agreement between the first and second scan was estimated using the Pearson correlation coefficient. A paired Wilcoxon rank-sum test was used to compare perfusion at baseline (BL) and during secretin stimulation. RESULTS The mean BL perfusion of the pancreatic head was 285 ± 96 mL/100 g/min with an intra-individual correlation coefficient of 0.67 (strong) for repeated measurements. Secretin stimulation led to a significant increase (by 81%) in perfusion of the pancreatic head to 486 ±156 mL/100 g/min (p=0.002) with an intra-individual correlation of 0.29 (weak). A return to BL values was observed after 239 ± 92 s with a moderate intra-individual correlation coefficient of 0.42 for repeat measurements. CONCLUSION Dynamic non-invasive ASL imaging of the pancreas permitted quantification of pancreatic perfusion in a clinically applicable setting. KEY POINTS • ASL imaging of the pancreas permitted quantification of pancreatic perfusion • Secretin stimulation led to a significant increase in pancreatic perfusion • The intra-individual correlation coefficient for baseline perfusion was strong for repeated measurements.
Collapse
Affiliation(s)
- Khoschy Schawkat
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland.
| | - Michael Ith
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | - Andreas Christe
- Department of Radiology, Tiefenau Hospital, Bern, Switzerland
| | - Wolfgang Kühn
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | - Yojena Chittazhathu
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | - Lauren Bains
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | - Val Murray Runge
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | - Johannes T Heverhagen
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
- Department of Clinical Research, University of Bern, Bern, Switzerland
| |
Collapse
|
9
|
Cox EF, Buchanan CE, Bradley CR, Prestwich B, Mahmoud H, Taal M, Selby NM, Francis ST. Multiparametric Renal Magnetic Resonance Imaging: Validation, Interventions, and Alterations in Chronic Kidney Disease. Front Physiol 2017; 8:696. [PMID: 28959212 PMCID: PMC5603702 DOI: 10.3389/fphys.2017.00696] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Accepted: 08/30/2017] [Indexed: 12/15/2022] Open
Abstract
Background: This paper outlines a multiparametric renal MRI acquisition and analysis protocol to allow non-invasive assessment of hemodynamics (renal artery blood flow and perfusion), oxygenation (BOLD T2*), and microstructure (diffusion, T1 mapping). Methods: We use our multiparametric renal MRI protocol to provide (1) a comprehensive set of MRI parameters [renal artery and vein blood flow, perfusion, T1, T2*, diffusion (ADC, D, D*, fp), and total kidney volume] in a large cohort of healthy participants (127 participants with mean age of 41 ± 19 years) and show the MR field strength (1.5 T vs. 3 T) dependence of T1 and T2* relaxation times; (2) the repeatability of multiparametric MRI measures in 11 healthy participants; (3) changes in MRI measures in response to hypercapnic and hyperoxic modulations in six healthy participants; and (4) pilot data showing the application of the multiparametric protocol in 11 patients with Chronic Kidney Disease (CKD). Results: Baseline measures were in-line with literature values, and as expected, T1-values were longer at 3 T compared with 1.5 T, with increased T1 corticomedullary differentiation at 3 T. Conversely, T2* was longer at 1.5 T. Inter-scan coefficients of variation (CoVs) of T1 mapping and ADC were very good at <2.9%. Intra class correlations (ICCs) were high for cortex perfusion (0.801), cortex and medulla T1 (0.848 and 0.997 using SE-EPI), and renal artery flow (0.844). In response to hypercapnia, a decrease in cortex T2* was observed, whilst no significant effect of hyperoxia on T2* was found. In CKD patients, renal artery and vein blood flow, and renal perfusion was lower than for healthy participants. Renal cortex and medulla T1 was significantly higher in CKD patients compared to healthy participants, with corticomedullary T1 differentiation reduced in CKD patients compared to healthy participants. No significant difference was found in renal T2*. Conclusions: Multiparametric MRI is a powerful technique for the assessment of changes in structure, hemodynamics, and oxygenation in a single scan session. This protocol provides the potential to assess the pathophysiological mechanisms in various etiologies of renal disease, and to assess the efficacy of drug treatments.
Collapse
Affiliation(s)
- Eleanor F Cox
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| | - Charlotte E Buchanan
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| | - Christopher R Bradley
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| | - Benjamin Prestwich
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| | - Huda Mahmoud
- Centre for Kidney Research and Innovation, Royal Derby Hospital, University of NottinghamDerby, United Kingdom
| | - Maarten Taal
- Centre for Kidney Research and Innovation, Royal Derby Hospital, University of NottinghamDerby, United Kingdom
| | - Nicholas M Selby
- Centre for Kidney Research and Innovation, Royal Derby Hospital, University of NottinghamDerby, United Kingdom
| | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, University of NottinghamNottingham, United Kingdom
| |
Collapse
|
10
|
Becker AS, Rossi C. Renal Arterial Spin Labeling Magnetic Resonance Imaging. Nephron Clin Pract 2016; 135:1-5. [PMID: 27760424 DOI: 10.1159/000450797] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Accepted: 09/06/2016] [Indexed: 12/13/2022] Open
Abstract
Arterial spin labeling (ASL) MRI allows the quantification of tissue perfusion without administration of exogenous contrast agents. Patients with reduced renal function or other contraindications to Gadolinium-based contrast media may benefit from the non-invasive monitoring of tissue microcirculation. So far, only few studies have investigated the sensitivity, the specificity and the reliability of the ASL techniques for the assessment of renal perfusion. Moreover, only little is known about the interplay between ASL markers of perfusion and functional renal filtration parameters. In this editorial, we discuss the main technical issues related to the quantification of renal perfusion by ASL and, in particular, the latest results in patients with kidney disorders.
Collapse
Affiliation(s)
- Anton S Becker
- Department of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
| | | |
Collapse
|
11
|
Hammon M, Janka R, Siegl C, Seuss H, Grosso R, Martirosian P, Schmieder RE, Uder M, Kistner I. Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment. Medicine (Baltimore) 2016; 95:e3083. [PMID: 26986143 PMCID: PMC4839924 DOI: 10.1097/md.0000000000003083] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Magnetic resonance imaging with arterial spin labeling (ASL) is a noninvasive approach to measure organ perfusion. The purpose of this study was to evaluate the reproducibility of ASL kidney perfusion measurements with semiautomatic segmentation, which allows separate quantification of cortical and medullary perfusion. The right kidneys of 14 healthy volunteers were examined 6 times on 2 occasions (3 times at each occasion). There was a 10-minute pause between each examination and a 14-day interval between the 2 occasions. Cortical, medullary, and whole kidney parenchymal perfusion was determined with customized semiautomatic segmentation software. Coefficient of variances (CVs) and intraclass correlations (ICCs) were calculated. Mean whole, cortical, and medullary kidney perfusion was 307.26 ± 25.65, 337.10 ± 34.83, and 279.61 ± 26.73 mL/min/100 g, respectively. On session 1, mean perfusion for the whole kidney, cortex, and medulla was 307.08 ± 26.91, 336.79 ± 36.54, and 279.60 ± 27.81 mL/min/100 g, respectively, and on session 2, 307.45 ± 24.65, 337.41 ± 33.48, and 279.61 ± 25.94 mL/min/100 g, respectively (P > 0.05; R² = 0.60/0.59/0.54). For whole, cortical, and medullary kidney perfusion, the total ICC/CV were 0.97/3.43 ± 0.86%, 0.97/4.19 ± 1.33%, and 0.96/4.12 ± 1.36%, respectively. Measurements did not differ significantly and showed a very good correlation (P > 0.05; R² = 0.75/0.76/0.65). ASL kidney measurements combined with operator-independent semiautomatic segmentation revealed high correlation and low variance of cortical, medullary, and whole kidney perfusion.
Collapse
Affiliation(s)
- Matthias Hammon
- From the Department of Radiology (MH, RJ, HS, MU), University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz, Erlangen, Germany; Department of Computer Graphics (CS, RG), Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße, Erlangen, Germany; Experimental Radiology, Department of Diagnostic and Interventional Radiology (PM), University Hospital Tübingen, Otfried-Müller-Straße, Tübingen, Germany; and Department of Nephrology and Hypertension (RES, IK), University Hospital Erlangen, Ulmenweg, Erlangen, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Park SH, Han PK, Choi SH. Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession. Korean J Radiol 2015; 16:550-9. [PMID: 25995684 PMCID: PMC4435985 DOI: 10.3348/kjr.2015.16.3.550] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Accepted: 02/05/2015] [Indexed: 12/01/2022] Open
Abstract
Balanced steady-state free precession (bSSFP) is a highly efficient pulse sequence that is known to provide the highest signal-to-noise ratio per unit time. Recently, bSSFP is getting increasingly popular in both the research and clinical communities. This review will be focusing on the application of the bSSFP technique in the context of probing the physiological and functional information. In the first part of this review, the basic principles of bSSFP are briefly covered. Afterwards, recent developments related to the application of bSSFP, in terms of physiological and functional imaging, are introduced and reviewed. Despite its long development history, bSSFP is still a promising technique that has many potential benefits for obtaining high-resolution physiological and functional images.
Collapse
Affiliation(s)
- Sung-Hong Park
- Magnetic Resonance Imaging Lab, Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701, Korea
| | - Paul Kyu Han
- Magnetic Resonance Imaging Lab, Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701, Korea
| | - Seung Hong Choi
- Department of Radiology, Seoul National University College of Medicine, Seoul 110-744, Korea
| |
Collapse
|
13
|
Zhang JL, Morrell G, Rusinek H, Sigmund EE, Chandarana H, Lerman LO, Prasad PV, Niles D, Artz N, Fain S, Vivier PH, Cheung AK, Lee VS. New magnetic resonance imaging methods in nephrology. Kidney Int 2014; 85:768-78. [PMID: 24067433 PMCID: PMC3965662 DOI: 10.1038/ki.2013.361] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2013] [Revised: 07/16/2013] [Accepted: 07/17/2013] [Indexed: 02/06/2023]
Abstract
Established as a method to study anatomic changes, such as renal tumors or atherosclerotic vascular disease, magnetic resonance imaging (MRI) to interrogate renal function has only recently begun to come of age. In this review, we briefly introduce some of the most important MRI techniques for renal functional imaging, and then review current findings on their use for diagnosis and monitoring of major kidney diseases. Specific applications include renovascular disease, diabetic nephropathy, renal transplants, renal masses, acute kidney injury, and pediatric anomalies. With this review, we hope to encourage more collaboration between nephrologists and radiologists to accelerate the development and application of modern MRI tools in nephrology clinics.
Collapse
Affiliation(s)
- Jeff L Zhang
- Department of Radiology, University of Utah, Salt Lake City, Utah, USA
| | - Glen Morrell
- Department of Radiology, University of Utah, Salt Lake City, Utah, USA
| | - Henry Rusinek
- Department of Radiology, New York University, New York, New York, USA
| | - Eric E Sigmund
- Department of Radiology, New York University, New York, New York, USA
| | - Hersh Chandarana
- Department of Radiology, New York University, New York, New York, USA
| | - Lilach O Lerman
- Department of Nephrology and Hypertension, Mayo Clinic, Rochester, MN, USA
| | | | - David Niles
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Nathan Artz
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Sean Fain
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | - Alfred K Cheung
- Division of Nephrology and Hypertension, University of Utah, Salt Lake City, Utah, USA
| | - Vivian S Lee
- Department of Radiology, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
14
|
Gillis KA, McComb C, Foster JE, Taylor AHM, Patel RK, Morris STW, Jardine AG, Schneider MP, Roditi GH, Delles C, Mark PB. Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla. BMC Nephrol 2014; 15:23. [PMID: 24484613 PMCID: PMC3909760 DOI: 10.1186/1471-2369-15-23] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2013] [Accepted: 01/28/2014] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Measurement of renal perfusion is a crucial part of measuring kidney function. Arterial spin labelling magnetic resonance imaging (ASL MRI) is a non-invasive method of measuring renal perfusion using magnetised blood as endogenous contrast. We studied the reproducibility of ASL MRI in normal volunteers. METHODS ASL MRI was performed in healthy volunteers on 2 occasions using a 3.0 Tesla MRI scanner with flow-sensitive alternating inversion recovery (FAIR) perfusion preparation with a steady state free precession (True-FISP) pulse sequence. Kidney volume was measured from the scanned images. Routine serum and urine biochemistry were measured prior to MRI scanning. RESULTS 12 volunteers were recruited yielding 24 kidneys, with a mean participant age of 44.1 ± 14.6 years, blood pressure of 136/82 mmHg and chronic kidney disease epidemiology formula estimated glomerular filtration rate (CKD EPI eGFR) of 98.3 ± 15.1 ml/min/1.73 m2. Mean kidney volumes measured using the ellipsoid formula and voxel count method were 123.5 ± 25.5 cm3, and 156.7 ± 28.9 cm3 respectively. Mean kidney perfusion was 229 ± 41 ml/min/100 g and mean cortical perfusion was 327 ± 63 ml/min/100 g, with no significant differences between ASL MRIs. Mean absolute kidney perfusion calculated from kidney volume measured during the scan was 373 ± 71 ml/min. Bland Altman plots were constructed of the cortical and whole kidney perfusion measurements made at ASL MRIs 1 and 2. These showed good agreement between measurements, with a random distribution of means plotted against differences observed. The intra class correlation for cortical perfusion was 0.85, whilst the within subject coefficient of variance was 9.2%. The intra class correlation for whole kidney perfusion was 0.86, whilst the within subject coefficient of variance was 7.1%. CONCLUSIONS ASL MRI at 3.0 Tesla provides a repeatable method of measuring renal perfusion in healthy subjects without the need for administration of exogenous compounds. We have established normal values for renal perfusion using ASL MRI in a cohort of healthy volunteers.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | - Patrick B Mark
- Institute of Cardiovascular and Medical Sciences, British Heart Foundation Glasgow Cardiovascular Research Centre, 126 University Place, Glasgow, UK.
| |
Collapse
|
15
|
Hueper K, Gutberlet M, Rong S, Hartung D, Mengel M, Lu X, Haller H, Wacker F, Meier M, Gueler F. Acute Kidney Injury: Arterial Spin Labeling to Monitor Renal Perfusion Impairment in Mice—Comparison with Histopathologic Results and Renal Function. Radiology 2014; 270:117-24. [DOI: 10.1148/radiol.13130367] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
16
|
Liss P, Cox EF, Eckerbom P, Francis ST. Imaging of intrarenal haemodynamics and oxygen metabolism. Clin Exp Pharmacol Physiol 2013; 40:158-67. [PMID: 23252679 DOI: 10.1111/1440-1681.12042] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2012] [Revised: 12/07/2012] [Accepted: 12/12/2012] [Indexed: 01/07/2023]
Abstract
The interruption of blood flow results in impaired oxygenation and metabolism. This can lead to electrophysiological changes, functional impairment and symptoms in quick succession. Quantitative measures of organ perfusion, perfusion reserve and tissue oxygenation are crucial to assess normal tissue metabolism and function. Magnetic resonance imaging (MRI) provides a number of quantitative methods to assess physiology in the kidney. Blood oxygenation level-dependent (BOLD) MRI provides a method for the assessment of oxygenation. Blood flow to the kidney can be assessed using phase contrast MRI. Dynamic contrast-enhanced MRI and arterial spin labelling (ASL) provide methods to assess tissue perfusion, ASL using the magnetization of endogenous water protons and thus providing a non-invasive method to assess perfusion. The application of diffusion-weighted MRI allows molecular motion in the kidney to be measured. Novel techniques can also be used to assess oxygenation in the renal arteries and veins and, combined with flow measures, provide an estimation of oxygen metabolism. Magnetic resonance imaging provides a synergy of non-invasive techniques to study renal function and the demand for these techniques is likely to be driven by the incentive to avoid the use of contrast media, to avoid radiation and to avoid complications with intervention procedures.
Collapse
Affiliation(s)
- Per Liss
- Department of Radiology, Center for Medical Imaging, Uppsala University Hospital, Uppsala University, Uppsala, Sweden
| | | | | | | |
Collapse
|
17
|
Rajendran R, Lew SK, Yong CX, Tan J, Wang DJJ, Chuang KH. Quantitative mouse renal perfusion using arterial spin labeling. NMR IN BIOMEDICINE 2013; 26:1225-1232. [PMID: 23592238 DOI: 10.1002/nbm.2939] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2012] [Revised: 12/30/2012] [Accepted: 02/08/2013] [Indexed: 06/02/2023]
Abstract
Information on renal perfusion is essential for the diagnosis and prognosis of kidney function. Quantification using gadolinium chelates is limited as a result of filtration through renal glomeruli and safety concerns in patients with kidney dysfunction. Arterial spin labeling MRI is a noninvasive technique for perfusion quantification that has been applied to humans and animals. However, because of the low sensitivity and vulnerability to motion and susceptibility artifacts, its application to mice has been challenging. In this article, mouse renal perfusion was studied using flow-sensitive alternating inversion recovery at 7 T. Good perfusion image quality was obtained with spin-echo echo-planar imaging after controlling for respiratory, susceptibility and fat artifacts by triggering, high-order shimming and water excitation, respectively. High perfusion was obtained in the renal cortex relative to the medulla, and signal was absent in scans carried out post mortem. Cortical perfusion increased from 397 ± 36 (mean ± standard deviation) to 476 ± 73 mL/100 g/min after switching from 100% oxygen to carbogen with 95% oxygen and 5% carbon dioxide. The perfusion in the medulla was 2.5 times lower than that in the cortex and changed from 166 ± 41 mL/100 g/min under oxygen to 203 ± 40 mL/100 g/min under carbogen. T1 decreased in both the cortex (from 1570 ± 164 to 1377 ± 72 ms, p < 0.05) and medulla (from 1788 ± 107 to 1573 ± 144 ms, p < 0.05) under carbogen relative to 100% oxygen. The results showed the potential of the use of ASL for perfusion quantification in mice and in models of renal diseases.
Collapse
Affiliation(s)
- Reshmi Rajendran
- Magnetic Resonance Imaging Group, Singapore Bioimaging Consortium, Agency for Science, Technology and Research, Singapore
| | | | | | | | | | | |
Collapse
|
18
|
|
19
|
Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model. Invest Radiol 2012; 46:124-31. [PMID: 22609830 DOI: 10.1097/rli.0b013e3181f5e101] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. MATERIALS AND METHODS Fluorescent microsphere and FAIR-ASL perfusion were compared in the cortex of the kidney for 11 swine across 4 interventional time points: (1) under baseline conditions, (2) during an acetylcholine and fluid bolus challenge to increase perfusion, (3) initially after switching to isoflurane anesthesia, and (4) after 2 hours of isoflurane anesthesia. In 10 of the 11 swine, a bag of ice was placed on the hilum of 1 kidney at the beginning of isoflurane administration to further reduce perfusion in 1 kidney. RESULTS Both ASL and microspheres tracked the expected cortical perfusion changes (P < 0.02) across the interventions, including an increase in perfusion during the acetylcholine challenge and decrease during the administration of isoflurane. Both techniques also measured lower cortical perfusion in the iced compared with the non-iced kidneys (P ≤ 0.01). The ASL values were systematically lower compared with microsphere perfusion. Very good correlation (r = 0.81, P < 0.0001) was observed between the techniques, and the relationship appeared linear for perfusion values in the expected physiologic range (microsphere perfusion <550 mL/min/100 g) although ASL values saturated for perfusion >550 mL/min/100 g. CONCLUSION Cortical perfusion measured with ASL correlated with microspheres and reliably detected changes in renal perfusion in response to physiologic challenge.
Collapse
|
20
|
Abstract
PURPOSE OF REVIEW In addition to excellent anatomical depiction, MRI techniques have expanded to study functional aspects of renal physiology, such as renal perfusion, glomerular filtration rate (GFR) or tissue oxygenation. This review will focus on current developments with an emphasis on clinical applicability. RECENT FINDINGS The method of GFR determination is largely heterogeneous and still has weaknesses. However, the technique of employing liver disappearance curves has been shown to be accurate in healthy persons and patients with chronic kidney disease. In potential kidney donors, complete evaluation of kidney anatomy and function can be accomplished in a single-stop investigation. Techniques without contrast media can be utilized to measure renal tissue oxygenation (blood oxygen level-dependent MRI) or perfusion (arterial spin labeling) and could aid in the diagnosis and treatment of ischemic renal diseases, such as renal artery stenosis. Diffusion imaging techniques may provide information on spatially restricted water diffusion and tumor cellularity. SUMMARY Functional MRI opens new horizons in studying renal physiology and pathophysiology in vivo. Although extensively utilized in research, labor-intensive postprocessing and lack of standardization currently limit the clinical applicability of functional MRI. Further studies are necessary to evaluate the clinical value of functional magnetic resonance techniques for early discovery and characterization of kidney disease.
Collapse
|
21
|
Current problems and future opportunities of abdominal magnetic resonance imaging at higher field strengths. Top Magn Reson Imaging 2011; 21:141-8. [PMID: 21847033 DOI: 10.1097/rmr.0b013e3181e8f9b9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Introduction of high-field-strength whole-body MR scanners to clinical routine made abdominal magnetic resonance (MR) imaging widely available. Higher field strength provides improved signal yield, but other issues such as shorter wavelength and increased power deposition of radiofrequency in tissue must also be taken into account. This review describes current problems and future opportunities of abdominal MR imaging at 3.0 T under special consideration of relevant physical properties and technical challenges: impact of higher field strength on signal-to-noise ratio, Larmor frequency, and chemical shift effects are elucidated in detail. Furthermore, changes in longitudinal and transverse relaxation times as well as increased susceptibility effects at 3.0 T are reported. General safety issues and limitations in radiofrequency power deposition are discussed. Subsequently, implications of the previously mentioned changed MR properties at 3.0 T on clinical abdominal examinations applying different sequence types are described.
Collapse
|
22
|
Schraml C, Schwenzer NF, Martirosian P, Claussen CD, Schick F. Temporal course of perfusion in human masseter muscle during isometric contraction assessed by arterial spin labeling at 3T. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2011; 24:201-9. [DOI: 10.1007/s10334-011-0254-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2010] [Revised: 04/19/2011] [Accepted: 04/19/2011] [Indexed: 11/29/2022]
|
23
|
Song R, Loeffler RB, Hillenbrand CM. Improved renal perfusion measurement with a dual navigator-gated Q2TIPS fair technique. Magn Reson Med 2011; 64:1352-9. [PMID: 20593428 DOI: 10.1002/mrm.22532] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A dual navigator-gated, flow-sensitive alternating inversion recovery (FAIR) true fast imaging with steady precession (True-FISP) sequence has been developed for accurate quantification of renal perfusion. FAIR methods typically overestimate renal perfusion when respiratory motion causes the inversion slice to move away from the imaging slice, which then incorporates unlabeled spins from static tissue. To overcome this issue, the dual navigator scheme was introduced to track inversion and imaging slices, and thus to ensure the same position for both slices. Accuracy was further improved by a well-defined bolus length, which was achieved by a modification version of Q2TIPS (quantitative imaging of perfusion using a single subtraction, second version with interleaved thin-slice TI(1) periodic saturation): a series of saturation pulses was applied to both sides of the imaging slice at a certain time after the inversion. The dual navigator-gated technique was tested in eight volunteers. The measured renal cortex perfusion rates were between 191 and 378 mL/100 g/min in the renal cortex with a mean of 376 mL/100 g/min. The proposed technique may prove most beneficial for noncontrast-based renal perfusion quantification in young children and patients who may have difficulty holding their breath for prolonged periods or are sedated/anesthetized.
Collapse
Affiliation(s)
- Ruitian Song
- Department of Radiological Sciences, Division of Translational Imaging Research, St. Jude Children's Research Hospital, Memphis, Tennessee 38105-3678, USA
| | | | | |
Collapse
|
24
|
Accuracy of multidetector CT scans in staging of renal carcinoma. Int J Surg 2011; 9:86-90. [DOI: 10.1016/j.ijsu.2010.07.304] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2010] [Revised: 07/20/2010] [Accepted: 07/28/2010] [Indexed: 01/29/2023]
|
25
|
Martirosian P, Boss A, Schraml C, Schwenzer NF, Graf H, Claussen CD, Schick F. Magnetic resonance perfusion imaging without contrast media. Eur J Nucl Med Mol Imaging 2010; 37 Suppl 1:S52-64. [PMID: 20461372 DOI: 10.1007/s00259-010-1456-7] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue. METHODS After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue. RESULTS ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time. CONCLUSIONS Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs.
Collapse
|
26
|
Arterial spin labeling MRI for assessment of perfusion in native and transplanted kidneys. Magn Reson Imaging 2010; 29:74-82. [PMID: 20850241 DOI: 10.1016/j.mri.2010.07.018] [Citation(s) in RCA: 72] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2010] [Revised: 07/01/2010] [Accepted: 07/13/2010] [Indexed: 12/29/2022]
Abstract
PURPOSE To apply a magnetic resonance arterial spin labeling (ASL) technique to evaluate kidney perfusion in native and transplanted kidneys. MATERIALS AND METHODS This study was compliant with the Health Insurance Portability and Accountability Act and approved by the institutional review board. Informed consent was obtained from all subjects. Renal perfusion exams were performed at 1.5 T in a total of 25 subjects: 10 with native and 15 with transplanted kidneys. A flow-sensitive alternating inversion recovery (FAIR) ASL sequence was performed with respiratory triggering in all subjects and under free-breathing conditions in five transplant subjects. Thirty-two control/tag pairs were acquired and processed using a single-compartment model. Perfusion in native and transplanted kidneys was compared above and below an estimated glomerular filtration rate (eGFR) threshold of 60 ml/min per 1.73 m² and correlations with eGFR were determined. RESULTS In many of the transplanted kidneys, major feeding vessels in the coronal plane required a slice orientation sagittal to the kidney. Renal motion during the examination was observed in native and transplant subjects and was corrected with registration. Cortical perfusion correlated with eGFR in native (r=0.85, P=.002) and transplant subjects (r=0.61, P=.02). For subjects with eGFR >60 ml/min per 1.73 m², native kidneys demonstrated greater cortical (P=.01) and medullary (P=.04) perfusion than transplanted kidneys. For subjects with eGFR <60 ml/min per 1.73 m², native kidneys demonstrated greater medullary perfusion (P=.04) compared to transplanted kidneys. Free-breathing acquisitions provided renal perfusion measurements that were slightly lower compared to the coached/triggered technique, although no statistical differences were observed. CONCLUSION In conclusion, FAIR-ASL was able to measure renal perfusion in subjects with native and transplanted kidneys, potentially providing a clinically viable technique for monitoring kidney function.
Collapse
|
27
|
Notohamiprodjo M, Reiser MF, Sourbron SP. Diffusion and perfusion of the kidney. Eur J Radiol 2010; 76:337-47. [PMID: 20580179 DOI: 10.1016/j.ejrad.2010.05.033] [Citation(s) in RCA: 132] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2010] [Accepted: 05/28/2010] [Indexed: 01/18/2023]
Abstract
MRI of the kidney currently makes the transition from depiction of morphology to assessment of function. Functional renal imaging methods provide information on diffusion and perfusion on a microstructural level. This review article presents the current status of functional renal imaging with focus on DWI (diffusion-weighted imaging) and DCE-MRI (dynamic contrast-enhanced MRI), as well as BOLD (blood-oxygenation level dependent) MRI, DTI (diffusion tensor imaging) and arterial spin labeling (ASL). Technical background of these techniques is explained and clinical assessment of renal function, parenchymal disease, transplant function and solid masses is discussed.
Collapse
Affiliation(s)
- Mike Notohamiprodjo
- Department of Clinical Radiology, University Hospitals Munich, Campus Großhadern, Marchioninistrasse 15, 81377 Munich, Germany.
| | | | | |
Collapse
|
28
|
Roditi G, Maki JH, Oliveira G, Michaely HJ. Renovascular imaging in the NSF Era. J Magn Reson Imaging 2010; 30:1323-34. [PMID: 19937926 DOI: 10.1002/jmri.21977] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
The detection of the association between nephrogenic systemic fibrosis (NSF), a rare but potentially life-threatening disease only encountered in patients with severely impaired renal function, and the previous administration of some Gd-chelates has cast a shadow on the administration of Gd-chelates in patients with chronic renal failure. So far, contrast-enhanced MR-angiography (MRA) was considered the best diagnostic modality in patients with suspected renal disease. This review explores the most appropriate use of renal MRA with a focus on newly developed nonenhanced MRA techniques. Nonenhanced MRA techniques mainly based on SSFP with ECG-gating allow for acceptable spatial resolution to visualize at least the proximal parts of the renal arteries. In addition functional renal imaging techniques and their current clinical role are critically appreciated. J. Magn. Reson. Imaging 2009;30:1323-1334. (c) 2009 Wiley-Liss, Inc.
Collapse
Affiliation(s)
- Giles Roditi
- Department of Radiology, Glasgow Royal Infirmary, Glasgow, G31 2ER Scotland, United Kingdom
| | | | | | | |
Collapse
|
29
|
Schraml C, Müssig K, Martirosian P, Schwenzer NF, Claussen CD, Häring HU, Balletshofer BM, Schick F. Autoimmune thyroid disease: arterial spin-labeling perfusion MR imaging. Radiology 2009; 253:435-42. [PMID: 19789231 DOI: 10.1148/radiol.2533090166] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To assess thyroid perfusion in patients with autoimmune thyroid diseases compared with that in healthy control subjects by using an arterial spin-labeling (ASL) magnetic resonance (MR) technique and to assess whether thyroid perfusion is associated with endocrine laboratory abnormalities. MATERIALS AND METHODS This study was approved by the local institutional review board. All participants gave written informed consent. Perfusion imaging of the thyroid gland was performed in 10 patients with Graves disease (GD) and 10 patients with Hashimoto thyroiditis (HT). Ten healthy individuals served as control subjects. Perfusion imaging was performed with a 1.5-T MR unit by using a flow-sensitive alternating inversion recovery-true fast imaging with steady-state precession technique. Perfusion maps of the entire thyroid gland were calculated on the basis of extended Bloch equations. Analysis of variance with a post hoc test (Tukey honestly significant difference) was performed to assess differences in perfusion between groups. Associations between perfusion and laboratory parameters were analyzed with univariate regression analysis. RESULTS Mean thyroid perfusion was 1596 mL/min/100 g +/- 436 (standard deviation) in patients with GD, 825 mL/min/100 g +/- 264 in patients with HT, and 491 mL/min/100 g +/- 89 in healthy control subjects. Perfusion was significantly higher in patients with GD (P < .0001) and those with HT (P < .05) than in control subjects. A significant difference in thyroid perfusion was detected between the two autoimmune entities (P < .0001). In patients with GD, significant associations were found between perfusion and serum concentrations of free thyroid hormones and anti-thyroid-stimulating hormone receptor antibodies (P < .05 for all). CONCLUSION Quantitative ASL perfusion imaging of the thyroid gland revealed significant perfusion differences in the autoimmune thyroid diseases GD and HT. Absolute quantification of thyroid perfusion may be useful in the clinical assessment of autoimmune thyroid disorders and when monitoring therapeutic treatment in GD.
Collapse
Affiliation(s)
- Christina Schraml
- Section on Experimental Radiology, Department of Diagnostic and Interventional Radiology, and Division of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry, University Hospital of Tübingen, Hoppe-Seyler-Str 3, 72076 Tübingen, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Leiner T, Michaely H. Advances in contrast-enhanced MR angiography of the renal arteries. Magn Reson Imaging Clin N Am 2008; 16:561-72, vii. [PMID: 18926422 DOI: 10.1016/j.mric.2008.07.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Renal artery stenosis (RAS) is a potentially curable cause of renovascular hypertension (RVH) and is caused by either atherosclerosis or fibromuscular dysplasia in the vast majority of patients. Although intra-arterial digital subtraction angiography is still considered the standard of reference test for the anatomic diagnosis of RAS, MR angiography and functional renal MR imaging are promising alternatives that also allow for functional characterization of RAS. This article provides an overview of these techniques and discusses their relative merits and shortcomings. Because missing RVH may have serious consequences the most important requirement for an alternative test is that it has high sensitivity. An unresolved issue is the prediction of functional recovery after therapy.
Collapse
Affiliation(s)
- Tim Leiner
- Department of Radiology, Maastricht University Hospital, Maastricht, The Netherlands.
| | | |
Collapse
|
31
|
Schwenzer NF, Schraml C, Martirosian P, Boss A, Claussen CD, Schick F. MR measurement of blood flow in the parotid gland without contrast medium: a functional study before and after gustatory stimulation. NMR IN BIOMEDICINE 2008; 21:598-605. [PMID: 18072228 DOI: 10.1002/nbm.1231] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
PURPOSE To investigate the feasibility of blood flow imaging in the parotid gland using the arterial spin labeling (ASL) technique for assessment of functional changes in the parotid gland after gustatory stimulation. MATERIALS AND METHODS Anatomical and ASL imaging of the parotid gland was performed in eight healthy volunteers before and after gustatory stimulation over a period of 17 min. All measurements were carried out in a 1.5 T whole-body MR unit. ASL and data recording were performed with an adapted FAIR TrueFISP (flow-sensitive alternating inversion-recovery true fast imaging with steady precession) technique. Maps of estimated tissue blood inflow in both parotid glands were derived using a simplified model and the extended Bloch equations. RESULTS Delineation of the parotid glands was possible on FAIR TrueFISP images in all cases. In the 160 s period immediately after stimulation, a significant (P < 0.01) mean increase of 62% in the estimated parotid blood flow was observed. Estimated baseline blood flow before gustatory stimulation ranged from 226 to 500 mL/min/100 g (mean +/- SD 335 +/- 86). These rates increased in the 160 s immediately after stimulation to 404-772 mL/min/100 g (mean 542 +/- 108). In all volunteers, blood flow returned to near baseline values within the observation period. No statistically significant difference between the right and left parotid was observed in baseline and peak blood flow. CONCLUSION ASL FAIR TrueFISP is feasible for functional characterization of the parotid glands. Assessment of changes in blood flow in the parotid gland could serve as a diagnostic tool in patients suffering from xerostomia.
Collapse
Affiliation(s)
- Nina F Schwenzer
- Section on Experimental Radiology, Eberhard-Karls University, Tübingen, Germany.
| | | | | | | | | | | |
Collapse
|
32
|
Machann J, Schlemmer HP, Schick F. Technical challenges and opportunities of whole-body magnetic resonance imaging at 3T. Phys Med 2008; 24:63-70. [DOI: 10.1016/j.ejmp.2008.01.011] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2007] [Revised: 01/09/2008] [Accepted: 01/15/2008] [Indexed: 11/25/2022] Open
|
33
|
Abstract
Clinically useful images of the kidneys, ureters, and bladder can be generated routinely on a 3T MR scanner. Although little has been published directly comparing 3.0-T MR imaging of the urinary tract with 1.5T imaging, the same benefits and limitations that apply to other areas of the body apply to urinary tract imaging at 3T. The potential benefits of improved signal-to-noise ratio and conspicuity of gadolinium enhancement and the potential for functional MR imaging of the kidneys at 3T are compelling, but need to be investigated further.
Collapse
Affiliation(s)
- John R Leyendecker
- Department of Radiology, Wake Forest University School of Medicine, Medical Center Boulevard, Winston-Salem, NC 27157, USA.
| | | |
Collapse
|
34
|
Nikken JJ, Krestin GP. MRI of the kidney-state of the art. Eur Radiol 2007; 17:2780-93. [PMID: 17646992 PMCID: PMC2039780 DOI: 10.1007/s00330-007-0701-3] [Citation(s) in RCA: 123] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2006] [Revised: 04/25/2007] [Accepted: 05/10/2007] [Indexed: 01/12/2023]
Abstract
Ultrasound and computed tomography (CT) are modalities of first choice in renal imaging. Until now, magnetic resonance imaging (MRI) has mainly been used as a problem-solving technique. MRI has the advantage of superior soft-tissue contrast, which provides a powerful tool in the detection and characterization of renal lesions. The MRI features of common and less common renal lesions are discussed as well as the evaluation of the spread of malignant lesions and preoperative assessment. MR urography technique and applications are discussed as well as the role of MRI in the evaluation of potential kidney donors. Furthermore the advances in functional MRI of the kidney are highlighted.
Collapse
Affiliation(s)
- J J Nikken
- Department of Radiology, Erasmus MC, University Medical Center Rotterdam, 's Gravendijkwal 230, 3015 CE, Rotterdam, The Netherlands.
| | | |
Collapse
|
35
|
Boss A, Martirosian P, Schaefer JF, Gehrmann M, Artunc F, Risler T, Oesingmann N, Claussen CD, Schlemmer HP, Schick F. Dynamic Magnetic Resonance Nephrography. Invest Radiol 2007; 42:256-62. [PMID: 17351433 DOI: 10.1097/01.rli.0000255810.78648.eb] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE In this volunteer study, 2 navigator-gated strongly T1-weighted saturation-recovery (SR) sequences, a turbo fast low angle shot (TurboFLASH) and a new true fast imaging in steady precession (TrueFISP) readout technique, were compared for suitability in dynamic magnetic resonance nephrography. MATERIALS AND METHODS Ten healthy volunteers (mean age 26.1 +/- 3.6) were equally divided into 2 subgroups. After bolus-injection of 3.75 mL of gadobutrol (approximately 0.05 mmol/kg body weight), slightly obliqued coronal single-slice images of the kidneys were recorded every 4-5 seconds during free breathing using 1 of the 2 sequences. Time-intensity curves were determined from manually drawn regions-of-interest over the kidney parenchyma. Both sequences were subsequently evaluated with regard to linearity of signal, signal to noise ratio (SNR), and time-dependent behavior of signal intensity curves. RESULTS : The TurboFLASH readout showed better linearity of the signal behavior as compared with the TrueFISP technique (TurboFLASH: no deviation from linearity down to T1 = 400 milliseconds; TrueFISP at T1 = 700 milliseconds: 12% deviation, at T1 = 400 milliseconds: 19%). The time-intensity curves of the TrueFISP sequence exhibited distinctly lower variability than the TurboFLASH approach. The SNR increased with TrueFISP by 3.4 +/- 0.5-fold for native renal parenchyma and by 3.3 +/- 0.9 for contrast-enhanced renal parenchyma. For split renal function evaluation, the linear regression to the signal increase in the first minutes after the first pass could be performed with higher reliability using the TrueFISP technique (increase of correlation coefficient by 17.1%). CONCLUSION A SR navigator-gated TrueFISP sequence seems most favorable for dynamic magnetic resonance nephrography due to the high signal yield and low curve variability.
Collapse
Affiliation(s)
- Andreas Boss
- Department of Diagnostic Radiology, Section of Experimental Radiology, Eberhard-Karls University, Tübingen, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Michaely HJ, Kramer H, Attenberger U, Sourbron SP, Weckbach S, Reiser MF, Schoenberg SO. Renal magnetic resonance angiography at 3.0 T: technical feasibility and clinical perspectives. Top Magn Reson Imaging 2007; 18:117-25. [PMID: 17621225 DOI: 10.1097/rmr.0b013e3180f6128e] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The increased signal-to-noise ratio at 3.0 T holds promise for high-spatial resolution renal magnetic resonance angiography (MRA). Today, state-of-the-art renal MRA is feasible with submillimeter isotropic spatial resolution in less than 20 seconds acquisition time with sufficient signal-to-noise ratio. This article explains the fundamentals of 3.0-T imaging that are essential for renal MRA, with a focus on the clinical implications. Protocol and imaging recommendations are given based on the physical principles of 3.0-T imaging and underlined by current clinical cases. Apart from pure morphological imaging, the value of functional renal imaging such as renal flow measurements and renal perfusion measurements for a comprehensive 3.0-T renal MRA protocol is discussed.
Collapse
Affiliation(s)
- Henrik J Michaely
- University Hospitals-Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany.
| | | | | | | | | | | | | |
Collapse
|