1
|
Liang J, Davoodi H, Wadhwa S, Badilita V, Korvink JG. Broadband stripline Lenz lens achieves 11 × NMR signal enhancement. Sci Rep 2024; 14:1645. [PMID: 38238376 PMCID: PMC10796323 DOI: 10.1038/s41598-023-50616-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 12/22/2023] [Indexed: 01/22/2024] Open
Abstract
A Lenz lens is an electrically passive conductive element that, when placed in a time-varying magnetic field, acts as a magnetic flux concentrator or a magnetic lens. In the realm of nuclear magnetic resonance (NMR), Lenz lenses have been exploited as electrically passive metallic radiofrequency interposers placed between a sample and a tuned or untuned NMR detector in order to focus the [Formula: see text]-field of the detector onto a smaller sample space. Here we explore a novel embodiment of the Lenz lens, which acts as a non-resonant stripline interposer, i.e., the [Formula: see text]-field acts along the longitudinal volume of a sample container, such as a capillary or other microfluidic channel that is coincident with the axis of the stripline. The almost vanishing self-resonance of the stripline Lenz lens, at frequencies relevant for NMR, leads to a desirable [Formula: see text]-field amplitude that is nearly perfectly uniform across the sample and hence lacking a characteristic sinusoidal modal shape. The action of Lenz' law ensures that no stray [Formula: see text]-field is found outside of the stripline's active volume. Because the stripline Lenz lens does not rely on its own geometry to achieve resonance, its frequency response is thus widely broadband for field enhancements up to a factor of 11, with only the external driving resonator properties governing the overall resonant behaviour. We explore the use of the stripline Lenz lens with a sub-nanolitre sample volume, readily detecting 4 isotopes with resonances ranging from 125.76 to 500 MHz. The concept holds potential for the NMR study of thin films, small biological samples, as well as the in situ study of battery materials.
Collapse
Affiliation(s)
- Jianyi Liang
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), 76344, Eggenstein-Leopoldshafen, Germany
| | | | | | - Vlad Badilita
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), 76344, Eggenstein-Leopoldshafen, Germany.
| | - Jan G Korvink
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), 76344, Eggenstein-Leopoldshafen, Germany.
| |
Collapse
|
2
|
Cheng YT, Korvink JG, Jouda M. A field focusing butterfly stripline detects NMR at higher signal-to-noise ratio. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 353:107517. [PMID: 37418779 DOI: 10.1016/j.jmr.2023.107517] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 06/23/2023] [Accepted: 06/25/2023] [Indexed: 07/09/2023]
Abstract
We present a compact tuned magnetic resonance detector that merges the conductor topology of a butterfly coil with that of a stripline, thereby increasing the magnetic field intensity B1 per unit current, which increases the detection signal-to-noise ratio for mass-limited samples by a factor of 2. The s-parameter measurements further reveal improved radiofrequency shielding through the suppression of B1 outside the coil when operated within an array of similar detectors. Simulations additionally show a sharper B1 fall-off for the butterfly stripline outside the sensitive sample region. Our design is compatible with 2D planar manufacturing procedures, such as printed circuit board technology, and surface micromachining.
Collapse
Affiliation(s)
- Yen-Tse Cheng
- Karlsruhe Institute of Technology (KIT), Institute of Microstructure Technology, Karlsruhe 76131, Germany
| | - Jan G Korvink
- Karlsruhe Institute of Technology (KIT), Institute of Microstructure Technology, Karlsruhe 76131, Germany.
| | - Mazin Jouda
- Karlsruhe Institute of Technology (KIT), Institute of Microstructure Technology, Karlsruhe 76131, Germany.
| |
Collapse
|
3
|
El Hariri El Nokab M, Sebakhy KO. Solid State NMR Spectroscopy a Valuable Technique for Structural Insights of Advanced Thin Film Materials: A Review. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:1494. [PMID: 34200088 PMCID: PMC8228666 DOI: 10.3390/nano11061494] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 05/31/2021] [Accepted: 06/02/2021] [Indexed: 01/05/2023]
Abstract
Solid-state NMR has proven to be a versatile technique for studying the chemical structure, 3D structure and dynamics of all sorts of chemical compounds. In nanotechnology and particularly in thin films, the study of chemical modification, molecular packing, end chain motion, distance determination and solvent-matrix interactions is essential for controlling the final product properties and applications. Despite its atomic-level research capabilities and recent technical advancements, solid-state NMR is still lacking behind other spectroscopic techniques in the field of thin films due to the underestimation of NMR capabilities, availability, great variety of nuclei and pulse sequences, lack of sensitivity for quadrupole nuclei and time-consuming experiments. This article will comprehensively and critically review the work done by solid-state NMR on different types of thin films and the most advanced NMR strategies, which are beyond conventional, and the hardware design used to overcome the technical issues in thin-film research.
Collapse
Affiliation(s)
- Mustapha El Hariri El Nokab
- Zernike Institute for Advanced Materials, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands;
| | - Khaled O. Sebakhy
- Engineering and Technology Institute Groningen, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands
| |
Collapse
|
4
|
Chen J, You X, Sun H, Tian J, Fang H, Xie J, Huang Y, Chen Z. Optimization of twin parallel microstrips based nuclear magnetic resonance probe for measuring the kinetics in molecular assembly in ultra-small samples. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:033106. [PMID: 33820024 DOI: 10.1063/5.0030452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Accepted: 02/26/2021] [Indexed: 06/12/2023]
Abstract
We present the design, fabrication, characterization, and optimization of a TPM (twin parallel microstrip)-based nuclear magnetic resonance (NMR) probe, produced by using a low-loss Teflon PTFE F4B high frequency circuit board. We use finite element analysis to optimize the radio frequency (RF) homogeneity and sensitivity of the TPM probe jointly for various sample volumes. The RF homogeneity of this TPM planar probe is superior to that of only a single microstrip probe. The optimized TPM probe properties such as RF homogeneity and field strength are characterized experimentally and discussed in detail. By combining this TPM based NMR probe with microfluidic technology, the sample amount required for kinetic study using NMR spectroscopy was minimized. This is important for studying costly samples. The TPM NMR probes provide high sensitivity to analysis of 5 µl samples with 2 mM concentrations within 10 min. The miniaturized microfluidic NMR probe plays an important role in realizing down to seconds timescale for kinetic monitoring.
Collapse
Affiliation(s)
- Jiahe Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, People's Republic of China
| | - Xueqiu You
- School of Information Engineering, Jimei University, Xiamen 361021, People's Republic of China
| | - Huijun Sun
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, People's Republic of China
| | - Jiaqin Tian
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, People's Republic of China
| | - Hongxun Fang
- State Key Laboratory of Physical Chemistry of Solid Surfaces, iChEM and College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, People's Republic of China
| | - Junyao Xie
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, People's Republic of China
| | - Yuqing Huang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, People's Republic of China
| | - Zhong Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, People's Republic of China
| |
Collapse
|
5
|
van Meerten S, van Zelst F, Tijssen K, Kentgens A. An Optimized NMR Stripline for Sensitive Supercritical Fluid Chromatography-Nuclear Magnetic Resonance of Microliter Sample Volumes. Anal Chem 2020; 92:13010-13016. [PMID: 32865394 PMCID: PMC7547862 DOI: 10.1021/acs.analchem.0c01827] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
![]()
To
optimize sensitivity, there has been an increasing interest
in the miniaturization of NMR detectors. In our lab, a stripline NMR
detector has been developed, which provides high resolution and is
scalable to a large range of sample volumes. These features make it
an ideal detector for hyphenated techniques. In this manuscript, we
demonstrate a stripline probe, which is designed for combining supercritical
fluid chromatography (SFC) experiments with NMR. It features a novel
stripline chip, designed to reduce the signal from the contact pads,
which results in an improved lineshape. An external lock circuit provides
stability over time to perform signal averaging or multidimensional
experiments. As proof of concept, we demonstrate the SFC-NMR technique
with this stripline probe using a mixture of cholesterol and cholestanol,
which is relevant for studying cerebrotendinous xanthomatosis. Additionally,
this probe makes it possible to record high-resolution spectra of
samples with a high spin density. This means that it is possible to
directly observe shifts due to the nuclear demagnetizing field in
the “homomolecular” case, which is challenging using
conventional probes due to broadening effects from radiation damping.
Collapse
Affiliation(s)
- Sebastiaan van Meerten
- Magnetic Resonance Research Center, Radboud University, Heyendaalseweg 135, Nijmegen 6525 AJ, The Netherlands
| | - Fleur van Zelst
- Magnetic Resonance Research Center, Radboud University, Heyendaalseweg 135, Nijmegen 6525 AJ, The Netherlands
| | - Koen Tijssen
- Magnetic Resonance Research Center, Radboud University, Heyendaalseweg 135, Nijmegen 6525 AJ, The Netherlands
| | - Arno Kentgens
- Magnetic Resonance Research Center, Radboud University, Heyendaalseweg 135, Nijmegen 6525 AJ, The Netherlands
| |
Collapse
|
6
|
Sahin Solmaz N, Grisi M, Matheoud AV, Gualco G, Boero G. Single-Chip Dynamic Nuclear Polarization Microsystem. Anal Chem 2020; 92:9782-9789. [PMID: 32530638 PMCID: PMC9559634 DOI: 10.1021/acs.analchem.0c01221] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
![]()
Integration
of the sensitivity-relevant electronics of nuclear
magnetic resonance (NMR) and electron spin resonance (ESR) spectrometers
on a single chip is a promising approach to improve the limit of detection,
especially for samples in the nanoliter and subnanoliter range. Here,
we demonstrate the cointegration on a single silicon chip of the front-end
electronics of NMR and ESR detectors. The excitation/detection planar
spiral microcoils of the NMR and ESR detectors are concentric and
interrogate the same sample volume. This combination of sensors allows
one to perform dynamic nuclear polarization (DNP) experiments using
a single-chip-integrated microsystem having an area of about 2 mm2. In particular, we report 1H DNP-enhanced NMR
experiments on liquid samples having a volume of about 1 nL performed
at 10.7 GHz(ESR)/16 MHz(NMR). NMR enhancements as large as 50 are
achieved on TEMPOL/H2O solutions at room temperature. The
use of state-of-the-art submicrometer integrated circuit technologies
should allow the future extension of the single-chip DNP microsystem
approach proposed here up the THz(ESR)/GHz(NMR) region, corresponding
to the strongest static magnetic fields currently available. Particularly
interesting is the possibility to create arrays of such sensors for
parallel DNP-enhanced NMR spectroscopy of nanoliter and subnanoliter
samples.
Collapse
Affiliation(s)
- Nergiz Sahin Solmaz
- School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Marco Grisi
- School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Alessandro V. Matheoud
- School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Gabriele Gualco
- School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Giovanni Boero
- School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| |
Collapse
|
7
|
Korvink JG, MacKinnon N, Badilita V, Jouda M. "Small is beautiful" in NMR. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 306:112-117. [PMID: 31337561 DOI: 10.1016/j.jmr.2019.07.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2019] [Revised: 05/31/2019] [Accepted: 07/08/2019] [Indexed: 05/03/2023]
Abstract
In this prospective paper we consider the opportunities and challenges of miniaturized nuclear magnetic resonance. As the title suggests, (irreverently borrowing from E.F. Schumacher's famous book), miniaturized NMR will feature a few small windows of opportunity for the analyst. We look at what these are, speculate on some open opportunities, but also comment on the challenges to progress.
Collapse
Affiliation(s)
- Jan G Korvink
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, P.O. Box 3640, 76021 Karlsruhe, Germany
| | - Neil MacKinnon
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, P.O. Box 3640, 76021 Karlsruhe, Germany
| | - Vlad Badilita
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, P.O. Box 3640, 76021 Karlsruhe, Germany
| | - Mazin Jouda
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, P.O. Box 3640, 76021 Karlsruhe, Germany
| |
Collapse
|
8
|
Sharma M, Utz M. Modular transmission line probes for microfluidic nuclear magnetic resonance spectroscopy and imaging. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 303:75-81. [PMID: 31026668 DOI: 10.1016/j.jmr.2019.04.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2019] [Revised: 03/30/2019] [Accepted: 04/09/2019] [Indexed: 06/09/2023]
Abstract
Microfluidic NMR spectroscopy can probe chemical and bio-chemical processes non-invasively in a tightly controlled environment. We present a dual-channel modular probe assembly for high efficiency microfluidic NMR spectroscopy and imaging. It is compatible with a wide range of microfluidic devices, without constraining the fluidic design. It collects NMR signals from a designated sample volume on the device with high sensitivity and resolution. Modular design allows adapting the detector geometry to different experimental conditions with minimal cost, by using the same probe base. The complete probe can be built from easily available parts. The probe body mainly consists of prefabricated aluminium profiles, while the probe circuit and detector are made from printed circuit boards. We demonstrate a double resonance HX probe with a limit of detection of 1.4 nmol s-1/2 for protons at 600 MHz, resolution of 3.35 Hz, and excellent B1 homogeneity. We have successfully acquired 1H-13C and 1H-15N heteronuclear correlation spectra (HSQC), including a 1H-15N HSQC spectrum of 1 mM 15N labeled ubiquitin in 2.5 μl of sample volume.
Collapse
Affiliation(s)
- Manvendra Sharma
- School of Chemistry, University of Southampton, Southampton SO17 1BJ, United Kingdom
| | - Marcel Utz
- School of Chemistry, University of Southampton, Southampton SO17 1BJ, United Kingdom
| |
Collapse
|
9
|
Oosthoek-de Vries AJ, Nieuwland PJ, Bart J, Koch K, Janssen JWG, van Bentum PJM, Rutjes FPJT, Gardeniers HJGE, Kentgens APM. Inline Reaction Monitoring of Amine-Catalyzed Acetylation of Benzyl Alcohol Using a Microfluidic Stripline Nuclear Magnetic Resonance Setup. J Am Chem Soc 2019; 141:5369-5380. [PMID: 30864795 PMCID: PMC6449804 DOI: 10.1021/jacs.9b00039] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Indexed: 12/30/2022]
Abstract
We present an in-depth study of the acetylation of benzyl alcohol in the presence of N, N-diisopropylethylamine (DIPEA) by nuclear magnetic resonance (NMR) monitoring of the reaction from 1.5 s to several minutes. We have adapted the NMR setup to be compatible to microreactor technology, scaling down the typical sample volume of commercial NMR probes (500 μL) to a microfluidic stripline setup with 150 nL detection volume. Inline spectra are obtained to monitor the kinetics and unravel the reaction mechanism of this industrially relevant reaction. The experiments are combined with conventional 2D NMR measurements to identify the reaction products. In addition, we replace DIPEA with triethylamine and pyridine to validate the reaction mechanism for different amine catalysts. In all three acetylation reactions, we find that the acetyl ammonium ion is a key intermediate. The formation of ketene is observed during the first minutes of the reaction when tertiary amines were present. The pyridine-catalyzed reaction proceeds via a different mechanism.
Collapse
Affiliation(s)
| | - Pieter J. Nieuwland
- Institute
of Molecules and Materials, Radboud University
Nijmegen, Nijmegen, The Netherlands
- FutureChemistry
Holding B.V., Nijmegen, The Netherlands
| | - Jacob Bart
- Institute
of Molecules and Materials, Radboud University
Nijmegen, Nijmegen, The Netherlands
| | - Kaspar Koch
- Institute
of Molecules and Materials, Radboud University
Nijmegen, Nijmegen, The Netherlands
- FutureChemistry
Holding B.V., Nijmegen, The Netherlands
| | - Johannes W. G. Janssen
- Institute
of Molecules and Materials, Radboud University
Nijmegen, Nijmegen, The Netherlands
| | - P. Jan M. van Bentum
- Institute
of Molecules and Materials, Radboud University
Nijmegen, Nijmegen, The Netherlands
| | - Floris P. J. T. Rutjes
- Institute
of Molecules and Materials, Radboud University
Nijmegen, Nijmegen, The Netherlands
| | | | - Arno P. M. Kentgens
- Institute
of Molecules and Materials, Radboud University
Nijmegen, Nijmegen, The Netherlands
| |
Collapse
|
10
|
Swyer I, von der Ecken S, Wu B, Jenne A, Soong R, Vincent F, Schmidig D, Frei T, Busse F, Stronks HJ, Simpson AJ, Wheeler AR. Digital microfluidics and nuclear magnetic resonance spectroscopy for in situ diffusion measurements and reaction monitoring. LAB ON A CHIP 2019; 19:641-653. [PMID: 30648175 DOI: 10.1039/c8lc01214h] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
In recent years microcoils and related structures have been developed to increase the mass sensitivity of nuclear magnetic resonance spectroscopy, allowing this extremely powerful analytical technique to be extended to small sample volumes (<5 μl). In general, microchannels have been used to deliver the samples of interest to these microcoils; however, these systems tend to have large dead volumes and require more complex fluidic connections. Here, we introduce a two-plate digital microfluidic (DMF) strategy to interface small-volume samples with NMR microcoils. In this system, a planar microcoil is surrounded by a copper plane that serves as the counter-electrode for the digital microfluidic device, allowing for precise control of droplet position and shape. This feature allows for the user-determination of the orientation of droplets relative to the main axes of the shim stack, permitting improved shimming and a more homogeneous magnetic field inside the droplet below the microcoil, which leads to improved spectral lineshape. This, along with high-fidelity droplet actuation, allows for rapid shimming strategies (developed over decades for vertically oriented NMR tubes) to be employed, permitting the determination of reaction-product diffusion coefficients as well as quantitative monitoring of reactive intermediates. We propose that this system paves the way for new and exciting applications for in situ analysis of small samples by NMR spectroscopy.
Collapse
Affiliation(s)
- Ian Swyer
- Department of Chemistry, University of Toronto, 80 St George St., Toronto, ON M5S 3H6, Canada.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
van Zelst FHM, van Meerten SGJ, van Bentum PJM, Kentgens APM. Hyphenation of Supercritical Fluid Chromatography and NMR with In-Line Sample Concentration. Anal Chem 2018; 90:10457-10464. [PMID: 30080387 PMCID: PMC6127797 DOI: 10.1021/acs.analchem.8b02357] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
![]()
By
coupling supercritical fluid chromatography (SFC) and nuclear
magnetic resonance (NMR) in-line, a powerful analytical method arises
that enables chemically specific analysis of a broad range of complex
mixtures. However, during chromatography, the compounds are diluted
in the mobile phase, in this case supercritical CO2 (scCO2), often resulting in concentrations that are too low to be
detected by NMR spectroscopy or at least requiring excessive signal
averaging. We present a hyphenated SFC-NMR setup with an integrated
approach for concentrating samples in-line, which are diluted in scCO2 during chromatography. This in-line concentration is achieved
by controlled in-line expansion of the scCO2. As a proof
of concept four isomers of vitamin E (tocopherol) were isolated by
SFC, concentrated in-line by expanding CO2 from 120 to
50 bar, and finally shuttled to the NMR spectrometer fitted with a
dedicated probehead for spectroscopic characterization of microfluidic
samples. The abundant isomers were readily detected, supporting the
viability of SFC-NMR as a powerful analytical tool.
Collapse
Affiliation(s)
- F H M van Zelst
- Institute for Molecules and Materials (IMM) , Radboud University , Nijmegen 6525 AJ , The Netherlands.,TA-COAST , Science Park 904 , Amsterdam 1098 XH , The Netherlands
| | - S G J van Meerten
- Institute for Molecules and Materials (IMM) , Radboud University , Nijmegen 6525 AJ , The Netherlands.,TA-COAST , Science Park 904 , Amsterdam 1098 XH , The Netherlands
| | - P J M van Bentum
- Institute for Molecules and Materials (IMM) , Radboud University , Nijmegen 6525 AJ , The Netherlands
| | - A P M Kentgens
- Institute for Molecules and Materials (IMM) , Radboud University , Nijmegen 6525 AJ , The Netherlands
| |
Collapse
|
12
|
Escribà-Gelonch M, Shahbazali E, Honing M, Hessel V. Quality-In(Process)Line (QuIProLi) process intensification for a micro-flow UV-photo synthesis enabled by online UHPLC analysis. Tetrahedron 2018. [DOI: 10.1016/j.tet.2018.02.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
13
|
Montinaro E, Grisi M, Letizia MC, Pethö L, Gijs MAM, Guidetti R, Michler J, Brugger J, Boero G. 3D printed microchannels for sub-nL NMR spectroscopy. PLoS One 2018; 13:e0192780. [PMID: 29742104 PMCID: PMC5942786 DOI: 10.1371/journal.pone.0192780] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Accepted: 01/30/2018] [Indexed: 11/19/2022] Open
Abstract
Nuclear magnetic resonance (NMR) experiments on subnanoliter (sub-nL) volumes are hindered by the limited sensitivity of the detector and the difficulties in positioning and holding such small samples in proximity of the detector. In this work, we report on NMR experiments on liquid and biological entities immersed in liquids having volumes down to 100 pL. These measurements are enabled by the fabrication of high spatial resolution 3D printed microfluidic structures, specifically conceived to guide and confine sub-nL samples in the sub-nL most sensitive volume of a single-chip integrated NMR probe. The microfluidic structures are fabricated using a two-photon polymerization 3D printing technique having a resolution better than 1 μm3. The high spatial resolution 3D printing approach adopted here allows to rapidly fabricate complex microfluidic structures tailored to position, hold, and feed biological samples, with a design that maximizes the NMR signals amplitude and minimizes the static magnetic field inhomogeneities. The layer separating the sample from the microcoil, crucial to exploit the volume of maximum sensitivity of the detector, has a thickness of 10 μm. To demonstrate the potential of this approach, we report NMR experiments on sub-nL intact biological entities in liquid media, specifically ova of the tardigrade Richtersius coronifer and sections of Caenorhabditis elegans nematodes. We show a sensitivity of 2.5x1013 spins/Hz1/2 on 1H nuclei at 7 T, sufficient to detect 6 pmol of 1H nuclei of endogenous compounds in active volumes down to 100 pL and in a measurement time of 3 hours. Spectral resolutions of 0.01 ppm in liquid samples and of 0.1 ppm in the investigated biological entities are also demonstrated. The obtained results may indicate a route for NMR studies at the single unit level of important biological entities having sub-nL volumes, such as living microscopic organisms and eggs of several mammalians, humans included.
Collapse
Affiliation(s)
- E. Montinaro
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratory for Microsystems, Lausanne, Switzerland
| | - M. Grisi
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratory for Microsystems, Lausanne, Switzerland
| | - M. C. Letizia
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratory for Microsystems, Lausanne, Switzerland
| | - L. Pethö
- Swiss Federal Laboratories for Materials Science and Technology (EMPA), Laboratory for Mechanics of Materials and Nanostructures, Thun, Switzerland
| | - M. A. M. Gijs
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratory for Microsystems, Lausanne, Switzerland
| | - R. Guidetti
- University of Modena and Reggio Emilia, Department of Life Sciences, Modena, Italy
| | - J. Michler
- Swiss Federal Laboratories for Materials Science and Technology (EMPA), Laboratory for Mechanics of Materials and Nanostructures, Thun, Switzerland
| | - J. Brugger
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratory for Microsystems, Lausanne, Switzerland
| | - G. Boero
- Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratory for Microsystems, Lausanne, Switzerland
| |
Collapse
|
14
|
Chen Y, Mehta HS, Butler MC, Walter ED, Reardon PN, Renslow RS, Mueller KT, Washton NM. High-resolution microstrip NMR detectors for subnanoliter samples. Phys Chem Chem Phys 2018; 19:28163-28174. [PMID: 29022609 DOI: 10.1039/c7cp03933f] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
We present the numerical optimization and experimental characterization of two microstrip-based nuclear magnetic resonance (NMR) detectors. The first detector, introduced in our previous work, was a flat wire detector with a strip resting on a substrate, and the second detector was created by adding a ground plane on top of the strip conductor, separated by a sample-carrying capillary and a thin layer of insulator. The dimensional parameters of the detectors were optimized using numerical simulations with regards to radio frequency (RF) sensitivity and homogeneity, with particular attention given to the effect of the ground plane. The influence of copper surface finish and substrate surface on the spectral resolution was investigated, and a resolution of 0.8-1.5 Hz was obtained on 1 nL deionized water depending on sample positioning. For 0.13 nmol sucrose (0.2 M in 0.63 nL H2O) encapsulated between two Fluorinert plugs, high RF homogeneity (A810°/A90° = 70-80%) and high sensitivity (expressed in the limit of detection nLODm = 0.73-1.21 nmol s1/2) were achieved, allowing for high-performance 2D NMR spectroscopy of subnanoliter samples.
Collapse
Affiliation(s)
- Ying Chen
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352, USA.
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Butler MC, Mehta HS, Chen Y, Reardon PN, Renslow RS, Khbeis M, Irish D, Mueller KT. Toward high-resolution NMR spectroscopy of microscopic liquid samples. Phys Chem Chem Phys 2018; 19:14256-14261. [PMID: 28534571 DOI: 10.1039/c7cp01933e] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A longstanding limitation of high-resolution NMR spectroscopy is the requirement for samples to have macroscopic dimensions. Commercial probes, for example, are designed for volumes of at least 5 μL, in spite of decades of work directed toward the goal of miniaturization. Progress in miniaturizing inductive detectors has been limited by a perceived need to meet two technical requirements: (1) minimal separation between the sample and the detector, which is essential for sensitivity, and (2) near-perfect magnetic-field homogeneity at the sample, which is typically needed for spectral resolution. The first of these requirements is real, but the second can be relaxed, as we demonstrate here. By using pulse sequences that yield high-resolution spectra in an inhomogeneous field, we eliminate the need for near-perfect field homogeneity and the accompanying requirement for susceptibility matching of microfabricated detector components. With this requirement removed, typical imperfections in microfabricated components can be tolerated, and detector dimensions can be matched to those of the sample, even for samples of volume ≪5 μL. Pulse sequences that are robust to field inhomogeneity thus enable small-volume detection with optimal sensitivity. We illustrate the potential of this approach to miniaturization by presenting spectra acquired with a flat-wire detector that can easily be scaled to subnanoliter volumes. In particular, we report high-resolution NMR spectroscopy of an alanine sample of volume 500 pL.
Collapse
Affiliation(s)
- Mark C Butler
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352, USA.
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Oosthoek-de Vries AJ, Bart J, Tiggelaar RM, Janssen JWG, van Bentum PJM, Gardeniers HJGE, Kentgens APM. Continuous Flow 1H and 13C NMR Spectroscopy in Microfluidic Stripline NMR Chips. Anal Chem 2017; 89:2296-2303. [PMID: 28194934 PMCID: PMC5337998 DOI: 10.1021/acs.analchem.6b03784] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2016] [Accepted: 01/23/2017] [Indexed: 12/28/2022]
Abstract
Microfluidic stripline NMR technology not only allows for NMR experiments to be performed on small sample volumes in the submicroliter range, but also experiments can easily be performed in continuous flow because of the stripline's favorable geometry. In this study we demonstrate the possibility of dual-channel operation of a microfluidic stripline NMR setup showing one- and two-dimensional 1H, 13C and heteronuclear NMR experiments under continuous flow. We performed experiments on ethyl crotonate and menthol, using three different types of NMR chips aiming for straightforward microfluidic connectivity. The detection volumes are approximately 150 and 250 nL, while flow rates ranging from 0.5 μL/min to 15 μL/min have been employed. We show that in continuous flow the pulse delay is determined by the replenishment time of the detector volume, if the sample trajectory in the magnet toward NMR detector is long enough to polarize the spin systems. This can considerably speed up quantitative measurement of samples needing signal averaging. So it can be beneficial to perform continuous flow measurements in this setup for analysis of, e.g., reactive, unstable, or mass-limited compounds.
Collapse
Affiliation(s)
| | - Jacob Bart
- Institute
of Molecules and Materials, Radboud University, 6525 HP Nijmegen, The Netherlands
- Mesoscale
Chemical Systems, MESA+ Institute of Nanotechnology, University of Twente, 7522
NB Enschede, The Netherlands
| | - Roald M. Tiggelaar
- Mesoscale
Chemical Systems, MESA+ Institute of Nanotechnology, University of Twente, 7522
NB Enschede, The Netherlands
| | - Johannes W. G. Janssen
- Institute
of Molecules and Materials, Radboud University, 6525 HP Nijmegen, The Netherlands
| | - P. Jan M. van Bentum
- Institute
of Molecules and Materials, Radboud University, 6525 HP Nijmegen, The Netherlands
| | - Han J. G. E. Gardeniers
- Mesoscale
Chemical Systems, MESA+ Institute of Nanotechnology, University of Twente, 7522
NB Enschede, The Netherlands
| | - Arno P. M. Kentgens
- Institute
of Molecules and Materials, Radboud University, 6525 HP Nijmegen, The Netherlands
| |
Collapse
|
17
|
A flow microslot NMR probe coupled with a capillary isotachophoresis system exhibits improved properties compared to solenoid designs. Anal Bioanal Chem 2017; 409:2471-2475. [DOI: 10.1007/s00216-017-0196-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Revised: 12/29/2016] [Accepted: 01/09/2017] [Indexed: 11/25/2022]
|
18
|
In vivo online magnetic resonance quantification of absolute metabolite concentrations in microdialysate. Sci Rep 2016; 6:36080. [PMID: 27811972 PMCID: PMC5095764 DOI: 10.1038/srep36080] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Accepted: 10/11/2016] [Indexed: 12/23/2022] Open
Abstract
In order to study metabolic processes in animal models of diseases and in patients, microdialysis probes have evolved as powerful tools that are minimally invasive. However, analyses of microdialysate, performed remotely, do not provide real-time monitoring of microdialysate composition. Microdialysate solutions can theoretically be analyzed online inside a preclicinal or clinical MRI scanner using MRS techniques. Due to low NMR sensitivity, acquisitions of real-time NMR spectra on very small solution volumes (μL) with low metabolite concentrations (mM range) represent a major issue. To address this challenge we introduce the approach of combining a microdialysis probe with a custom-built magnetic resonance microprobe that allows for online metabolic analysis (1H and 13C) with high sensitivity under continuous flow conditions. This system is mounted inside an MRI scanner and allows performing simultaneously MRI experiments and rapid MRS metabolic analysis of the microdialysate. The feasibility of this approach is demonstrated by analyzing extracellular brain cancer cells (glioma) in vitro and brain metabolites in an animal model in vivo. We expect that our approach is readily translatable into clinical settings and can be used for a better and precise understanding of diseases linked to metabolic dysfunction.
Collapse
|
19
|
Swyer I, Soong R, Dryden MDM, Fey M, Maas WE, Simpson A, Wheeler AR. Interfacing digital microfluidics with high-field nuclear magnetic resonance spectroscopy. LAB ON A CHIP 2016; 16:4424-4435. [PMID: 27757467 DOI: 10.1039/c6lc01073c] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Nuclear magnetic resonance (NMR) spectroscopy is extremely powerful for chemical analysis but it suffers from lower mass sensitivity compared to many other analytical detection methods. NMR microcoils have been developed in response to this limitation, but interfacing these coils with small sample volumes is a challenge. We introduce here the first digital microfluidic system capable of interfacing droplets of analyte with microcoils in a high-field NMR spectrometer. A finite element simulation was performed to assist in determining appropriate system parameters. After optimization, droplets inside the spectrometer could be controlled remotely, permitting the observation of processes such as xylose-borate complexation and glucose oxidase catalysis. We propose that the combination of DMF and NMR will be a useful new tool for a wide range of applications in chemical analysis.
Collapse
Affiliation(s)
- Ian Swyer
- Department of Chemistry, University of Toronto, 80 St. George St, Toronto, ON M5S 3H6, Canada.
| | - Ronald Soong
- Department of Chemistry, University of Toronto Scarborough, 1256 Military Trail, Toronto, ON M1C 1A4, Canada.
| | - Michael D M Dryden
- Department of Chemistry, University of Toronto, 80 St. George St, Toronto, ON M5S 3H6, Canada.
| | - Michael Fey
- Bruker BioSpin Corp, 15 Fortune Drive, Billerica, Massachusetts 01821-3991, USA
| | - Werner E Maas
- Bruker BioSpin Corp, 15 Fortune Drive, Billerica, Massachusetts 01821-3991, USA
| | - André Simpson
- Department of Chemistry, University of Toronto Scarborough, 1256 Military Trail, Toronto, ON M1C 1A4, Canada.
| | - Aaron R Wheeler
- Department of Chemistry, University of Toronto, 80 St. George St, Toronto, ON M5S 3H6, Canada. and Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, 160 College St, Toronto, ON M5S 3E1, Canada and Institute for Biomaterials and Biomedical Engineering, University of Toronto, 164 College St, Toronto, ON M5S 3G9, Canada
| |
Collapse
|
20
|
A Multidisciplinary Approach to High Throughput Nuclear Magnetic Resonance Spectroscopy. SENSORS 2016; 16:s16060850. [PMID: 27294925 PMCID: PMC4934276 DOI: 10.3390/s16060850] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Revised: 05/30/2016] [Accepted: 06/02/2016] [Indexed: 02/03/2023]
Abstract
Nuclear Magnetic Resonance (NMR) is a non-contact, powerful structure-elucidation technique for biochemical analysis. NMR spectroscopy is used extensively in a variety of life science applications including drug discovery. However, existing NMR technology is limited in that it cannot run a large number of experiments simultaneously in one unit. Recent advances in micro-fabrication technologies have attracted the attention of researchers to overcome these limitations and significantly accelerate the drug discovery process by developing the next generation of high-throughput NMR spectrometers using Complementary Metal Oxide Semiconductor (CMOS). In this paper, we examine this paradigm shift and explore new design strategies for the development of the next generation of high-throughput NMR spectrometers using CMOS technology. A CMOS NMR system consists of an array of high sensitivity micro-coils integrated with interfacing radio-frequency circuits on the same chip. Herein, we first discuss the key challenges and recent advances in the field of CMOS NMR technology, and then a new design strategy is put forward for the design and implementation of highly sensitive and high-throughput CMOS NMR spectrometers. We thereafter discuss the functionality and applicability of the proposed techniques by demonstrating the results. For microelectronic researchers starting to work in the field of CMOS NMR technology, this paper serves as a tutorial with comprehensive review of state-of-the-art technologies and their performance levels. Based on these levels, the CMOS NMR approach offers unique advantages for high resolution, time-sensitive and high-throughput bimolecular analysis required in a variety of life science applications including drug discovery.
Collapse
|
21
|
Yilmaz A, Utz M. Characterisation of oxygen permeation into a microfluidic device for cell culture by in situ NMR spectroscopy. LAB ON A CHIP 2016; 16:2079-2085. [PMID: 27149932 DOI: 10.1039/c6lc00396f] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A compact microfluidic device for perfusion culture of mammalian cells under in situ metabolomic observation by NMR spectroscopy is presented. The chip is made from poly(methyl methacrylate) (PMMA), and uses a poly(dimethyl siloxane) (PDMS) membrane to allow gas exchange. It is integrated with a generic micro-NMR detector developed recently by our group [J. Magn. Reson., 2016, 262, 73-80]. While PMMA is an excellent material in the context of NMR, PDMS is known to produce strong background signals. To mitigate this, the device keeps the PDMS away from the detection area. The oxygen permeation into the device is quantified using a flow chemistry approach. A solution of glucose is mixed on the chip with a solution of glucose oxidase, before flowing through the gas exchanger. The resulting concentration of gluconate is measured by (1)H NMR spectroscopy as a function of flow rate. An oxygen equilibration rate constant of 2.4 s(-1) is found for the device, which is easily sufficient to maintain normoxic conditions in a cell culture at low perfusion flow rates.
Collapse
Affiliation(s)
- Ali Yilmaz
- School of Chemistry, University of Southampton, SO17 1BJ, UK.
| | - Marcel Utz
- School of Chemistry, University of Southampton, SO17 1BJ, UK.
| |
Collapse
|
22
|
Zhang H, Tiggelaar RM, Schlautmann S, Bart J, Gardeniers H. In-line sample concentration by evaporation through porous hollow fibers and micromachined membranes embedded in microfluidic devices. Electrophoresis 2015; 37:463-71. [DOI: 10.1002/elps.201500285] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2015] [Revised: 07/31/2015] [Accepted: 07/31/2015] [Indexed: 12/24/2022]
Affiliation(s)
- Hainan Zhang
- Mesoscale Chemical Systems Group, MESA+ Institute for Nanotechnology; University of Twente, Enschede; The Netherlands
| | - Roald M. Tiggelaar
- Mesoscale Chemical Systems Group, MESA+ Institute for Nanotechnology; University of Twente, Enschede; The Netherlands
| | - Stefan Schlautmann
- Mesoscale Chemical Systems Group, MESA+ Institute for Nanotechnology; University of Twente, Enschede; The Netherlands
| | - Jacob Bart
- Mesoscale Chemical Systems Group, MESA+ Institute for Nanotechnology; University of Twente, Enschede; The Netherlands
| | - Han Gardeniers
- Mesoscale Chemical Systems Group, MESA+ Institute for Nanotechnology; University of Twente, Enschede; The Netherlands
| |
Collapse
|
23
|
Takeda K, Takasaki T, Takegoshi K. Susceptibility cancellation of a microcoil wound with a paramagnetic-liquid-filled copper capillary. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2015; 258:1-5. [PMID: 26150376 DOI: 10.1016/j.jmr.2015.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Revised: 06/09/2015] [Accepted: 06/11/2015] [Indexed: 06/04/2023]
Abstract
Even though microcoils improve the sensitivity of NMR measurement of tiny samples, magnetic-field inhomogeneity due to the bulk susceptibility effect of the coil material can cause serious resonance-line broadening. Here, we propose to fabricate the microcoil using a thin, hollow copper capillary instead of a wire and fill paramagnetic liquid inside the capillary, so as to cancel the diamagnetic contribution of the copper. Susceptibility cancellation is demonstrated using aqueous solution of NiSO4. In addition, the paramagnetic liquid serves as coolant when it is circulated through the copper capillary, effectively transferring the heat generated by radiofrequency pulses.
Collapse
Affiliation(s)
- Kazuyuki Takeda
- Division of Chemistry, Graduate School of Science, Kyoto University, 606-8502 Kyoto, Japan.
| | - Tomoya Takasaki
- Division of Chemistry, Graduate School of Science, Kyoto University, 606-8502 Kyoto, Japan
| | - K Takegoshi
- Division of Chemistry, Graduate School of Science, Kyoto University, 606-8502 Kyoto, Japan
| |
Collapse
|
24
|
Kalfe A, Telfah A, Lambert J, Hergenröder R. Looking into Living Cell Systems: Planar Waveguide Microfluidic NMR Detector for in Vitro Metabolomics of Tumor Spheroids. Anal Chem 2015; 87:7402-10. [DOI: 10.1021/acs.analchem.5b01603] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Ayten Kalfe
- Leibniz Institut für analytische Wissenschaften - ISAS e.V., Bunsen-Kirchhoff-Strasse 11, 44139 Dortmund, Germany
| | - Ahmad Telfah
- Leibniz Institut für analytische Wissenschaften - ISAS e.V., Bunsen-Kirchhoff-Strasse 11, 44139 Dortmund, Germany
| | - Jörg Lambert
- Leibniz Institut für analytische Wissenschaften - ISAS e.V., Bunsen-Kirchhoff-Strasse 11, 44139 Dortmund, Germany
| | - Roland Hergenröder
- Leibniz Institut für analytische Wissenschaften - ISAS e.V., Bunsen-Kirchhoff-Strasse 11, 44139 Dortmund, Germany
| |
Collapse
|
25
|
Causier A, Carret G, Boutin C, Berthelot T, Berthault P. 3D-printed system optimizing dissolution of hyperpolarized gaseous species for micro-sized NMR. LAB ON A CHIP 2015; 15:2049-2054. [PMID: 25805248 DOI: 10.1039/c5lc00193e] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Dissolution of hyperpolarized species in liquids of interest for NMR is often hampered by the presence of bubbles that degrade the field homogeneity. Here a device composed of a bubble pump and a miniaturized NMR cell both fitted inside the narrow bore of an NMR magnet is built by 3D printing. (129)Xe NMR experiments performed with hyperpolarized xenon reveal high and homogeneous dissolution of the gas in water.
Collapse
Affiliation(s)
- A Causier
- Laboratoire d'Innovation en Chimie des Surfaces et Nanosciences, CEA Saclay, IRAMIS, NIMBE, UMR CEA/CNRS 3685, 91191 Gif sur Yvette, France
| | | | | | | | | |
Collapse
|
26
|
Vasdekis AE, Stephanopoulos G. Review of methods to probe single cell metabolism and bioenergetics. Metab Eng 2015; 27:115-135. [PMID: 25448400 PMCID: PMC4399830 DOI: 10.1016/j.ymben.2014.09.007] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2014] [Revised: 09/18/2014] [Accepted: 09/19/2014] [Indexed: 11/26/2022]
Abstract
Single cell investigations have enabled unexpected discoveries, such as the existence of biological noise and phenotypic switching in infection, metabolism and treatment. Herein, we review methods that enable such single cell investigations specific to metabolism and bioenergetics. Firstly, we discuss how to isolate and immobilize individuals from a cell suspension, including both permanent and reversible approaches. We also highlight specific advances in microbiology for its implications in metabolic engineering. Methods for probing single cell physiology and metabolism are subsequently reviewed. The primary focus therein is on dynamic and high-content profiling strategies based on label-free and fluorescence microspectroscopy and microscopy. Non-dynamic approaches, such as mass spectrometry and nuclear magnetic resonance, are also briefly discussed.
Collapse
Affiliation(s)
- Andreas E Vasdekis
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, PO Box 999, Richland, WA 99354, USA.
| | - Gregory Stephanopoulos
- Department of Chemical Engineering, Massachusetts Institute of Technology, Room 56-469, Cambridge, MA 02139, USA.
| |
Collapse
|
27
|
Ryan H, Smith A, Utz M. Structural shimming for high-resolution nuclear magnetic resonance spectroscopy in lab-on-a-chip devices. LAB ON A CHIP 2014; 14:1678-1685. [PMID: 24658666 DOI: 10.1039/c3lc51431e] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
High-resolution proton NMR spectroscopy is well-established as a tool for metabolomic analysis of biological fluids at the macro scale. Its full potential has, however, not been realised yet in the context of microfluidic devices. While microfabricated NMR detectors offer substantial gains in sensitivity, limited spectral resolution resulting from mismatches in the magnetic susceptibility of the sample fluid and the chip material remains a major hurdle. In this contribution, we show that susceptibility broadening can be avoided even in the presence of substantial mismatch by including suitably shaped compensation structures into the chip design. An efficient algorithm for the calculation of field maps from arbitrary chip layouts based on Gaussian quadrature is used to optimise the shape of the compensation structure to ensure a flat field distribution inside the sample area. Previously, the complexity of microfluidic NMR systems has been restricted to simple capillaries to avoid susceptibility broadening. The structural shimming approach introduced here can be adapted to virtually any shape of sample chamber and surrounding fluidic network, thereby greatly expanding the design space and enabling true lab-on-a-chip systems suitable for high-resolution NMR detection.
Collapse
Affiliation(s)
- Herbert Ryan
- School of Chemistry, University of Southampton, Highfield Campus, Southampton SO17 1BJ, UK.
| | | | | |
Collapse
|
28
|
Zalesskiy SS, Danieli E, Blümich B, Ananikov VP. Miniaturization of NMR systems: desktop spectrometers, microcoil spectroscopy, and "NMR on a chip" for chemistry, biochemistry, and industry. Chem Rev 2014; 114:5641-94. [PMID: 24779750 DOI: 10.1021/cr400063g] [Citation(s) in RCA: 137] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Sergey S Zalesskiy
- Zelinsky Institute of Organic Chemistry, Russian Academy of Sciences , Moscow, 119991, Russia
| | | | | | | |
Collapse
|
29
|
Proietti N, Capitani D, Di Tullio V. Applications of nuclear magnetic resonance sensors to cultural heritage. SENSORS 2014; 14:6977-97. [PMID: 24755519 PMCID: PMC4029666 DOI: 10.3390/s140406977] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2014] [Revised: 04/08/2014] [Accepted: 04/15/2014] [Indexed: 11/24/2022]
Abstract
In recent years nuclear magnetic resonance (NMR) sensors have been increasingly applied to investigate, characterize and monitor objects of cultural heritage interest. NMR is not confined to a few specific applications, but rather its use can be successfully extended to a wide number of different cultural heritage issues. A breakthrough has surely been the recent development of portable NMR sensors which can be applied in situ for non-destructive and non-invasive investigations. In this paper three studies illustrating the potential of NMR sensors in this field of research are reported.
Collapse
Affiliation(s)
- Noemi Proietti
- Laboratorio di Risonanza Magnetica "Annalaura Segre", Istituto di Metodologie Chimiche, CNR Area della Ricerca di Roma 1, Via Salaria Km 29,300, 00015 Monterotondo (Rome), Italy.
| | - Donatella Capitani
- Laboratorio di Risonanza Magnetica "Annalaura Segre", Istituto di Metodologie Chimiche, CNR Area della Ricerca di Roma 1, Via Salaria Km 29,300, 00015 Monterotondo (Rome), Italy.
| | - Valeria Di Tullio
- Laboratorio di Risonanza Magnetica "Annalaura Segre", Istituto di Metodologie Chimiche, CNR Area della Ricerca di Roma 1, Via Salaria Km 29,300, 00015 Monterotondo (Rome), Italy.
| |
Collapse
|
30
|
Bonhomme C, Gervais C, Laurencin D. Recent NMR developments applied to organic-inorganic materials. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2014; 77:1-48. [PMID: 24411829 DOI: 10.1016/j.pnmrs.2013.10.001] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2013] [Accepted: 10/17/2013] [Indexed: 06/03/2023]
Abstract
In this contribution, the latest developments in solid state NMR are presented in the field of organic-inorganic (O/I) materials (or hybrid materials). Such materials involve mineral and organic (including polymeric and biological) components, and can exhibit complex O/I interfaces. Hybrids are currently a major topic of research in nanoscience, and solid state NMR is obviously a pertinent spectroscopic tool of investigation. Its versatility allows the detailed description of the structure and texture of such complex materials. The article is divided in two main parts: in the first one, recent NMR methodological/instrumental developments are presented in connection with hybrid materials. In the second part, an exhaustive overview of the major classes of O/I materials and their NMR characterization is presented.
Collapse
Affiliation(s)
- Christian Bonhomme
- Laboratoire de Chimie de la Matière Condensée de Paris, UMR CNRS 7574, Université Pierre et Marie Curie, Paris 06, Collège de France, 11 Place Marcelin Berthelot, 75231 Paris Cedex 05, France.
| | - Christel Gervais
- Laboratoire de Chimie de la Matière Condensée de Paris, UMR CNRS 7574, Université Pierre et Marie Curie, Paris 06, Collège de France, 11 Place Marcelin Berthelot, 75231 Paris Cedex 05, France
| | - Danielle Laurencin
- Institut Charles Gerhardt de Montpellier, UMR5253, CNRS UM2 UM1 ENSCM, CC1701, Place Eugène Bataillon, 34095 Montpellier Cedex 05, France
| |
Collapse
|
31
|
Multinuclear nanoliter one-dimensional and two-dimensional NMR spectroscopy with a single non-resonant microcoil. Nat Commun 2014; 5:3025. [DOI: 10.1038/ncomms4025] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Accepted: 11/26/2013] [Indexed: 11/08/2022] Open
|
32
|
Yap YS, Yamamoto H, Tabuchi Y, Negoro M, Kagawa A, Kitagawa M. Strongly driven electron spins using a K(u) band stripline electron paramagnetic resonance resonator. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2013; 232:62-67. [PMID: 23703225 DOI: 10.1016/j.jmr.2013.04.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Revised: 04/23/2013] [Accepted: 04/26/2013] [Indexed: 06/02/2023]
Abstract
This article details our work to obtain strong excitation for electron paramagnetic resonance (EPR) experiments by improving the resonator's efficiency. The advantages and application of strong excitation are discussed. Two 17 GHz transmission-type, stripline resonators were designed, simulated and fabricated. Scattering parameter measurements were carried out and quality factor were measured to be around 160 and 85. Simulation results of the microwave's magnetic field distribution are also presented. To determine the excitation field at the sample, nutation experiments were carried out and power dependence were measured using two organic samples at room temperature. The highest recorded Rabi frequency was rated at 210 MHz with an input power of about 1 W, which corresponds to a π/2 pulse of about 1.2 ns.
Collapse
Affiliation(s)
- Yung Szen Yap
- Graduate School of Engineering Science, Osaka University, Japan.
| | | | | | | | | | | |
Collapse
|
33
|
Webb AG. Radiofrequency microcoils for magnetic resonance imaging and spectroscopy. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2013; 229:55-66. [PMID: 23142002 DOI: 10.1016/j.jmr.2012.10.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2012] [Revised: 10/07/2012] [Accepted: 10/09/2012] [Indexed: 06/01/2023]
Abstract
Small radiofrequency coils, often termed "microcoils", have found extensive use in many areas of magnetic resonance. Their advantageous properties include a very high intrinsic sensitivity, a high (several MHz) excitation and reception bandwidth, the fact that large arrays can fit within the homogeneous volume of the static magnetic field, and the very high resonance frequencies (several GHz) that can be achieved. This review concentrates on recent developments in the construction of single and multiple RF microcoil systems, and new types of experiments that can be performed using such assemblies.
Collapse
Affiliation(s)
- A G Webb
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
| |
Collapse
|
34
|
Yue J, Schouten JC, Nijhuis TA. Integration of Microreactors with Spectroscopic Detection for Online Reaction Monitoring and Catalyst Characterization. Ind Eng Chem Res 2012. [DOI: 10.1021/ie301258j] [Citation(s) in RCA: 98] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Jun Yue
- Laboratory of Chemical Reactor Engineering, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology,
P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Jaap C. Schouten
- Laboratory of Chemical Reactor Engineering, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology,
P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - T. Alexander Nijhuis
- Laboratory of Chemical Reactor Engineering, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology,
P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| |
Collapse
|
35
|
Takeda K. Microcoils and microsamples in solid-state NMR. SOLID STATE NUCLEAR MAGNETIC RESONANCE 2012; 47-48:1-9. [PMID: 23083521 DOI: 10.1016/j.ssnmr.2012.09.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2012] [Revised: 09/13/2012] [Accepted: 09/14/2012] [Indexed: 06/01/2023]
Abstract
Recent reports on microcoils are reviewed. The first part of the review includes a discussion of how the geometries of the sample and coil affect the NMR signal intensity. In addition to derivation of the well-known result that the signal intensity increases as the coil size decreases, the prediction that dilution of a small sample with magnetically inert matter leads to better sensitivity if a tiny coil is not available is given. The second part of the review focuses on the issues specific to solid-state NMR. They include realization of magic-angle spinning (MAS) using a microcoil and harnessing of such strong pulses that are feasible only with a microcoil. Two strategies for microcoil MAS, the piggyback method and magic-angle coil spinning (MACS), are reviewed. In addition, MAS of flat, disk-shaped samples is discussed in the context of solid-state NMR of small-volume samples. Strong RF irradiation, which has been exploited in wide-line spectral excitation, multiple-quantum MAS (MQMAS), and dipolar decoupling experiments, has been accompanied by new challenges regarding the Bloch-Siegert effect, the minimum time resolution of the spectrometer, and the time scale of pulse transient effects. For a possible solution to the latter problem, recent reports on active compensation of pulse transients are described.
Collapse
Affiliation(s)
- Kazuyuki Takeda
- Division of Chemistry, Graduate School of Science, Kyoto University, 606-8502 Kyoto, Japan.
| |
Collapse
|
36
|
Microfabricated inserts for magic angle coil spinning (MACS) wireless NMR spectroscopy. PLoS One 2012; 7:e42848. [PMID: 22936994 PMCID: PMC3423418 DOI: 10.1371/journal.pone.0042848] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2012] [Accepted: 07/12/2012] [Indexed: 11/19/2022] Open
Abstract
This article describes the development and testing of the first automatically microfabricated probes to be used in conjunction with the magic angle coil spinning (MACS) NMR technique. NMR spectroscopy is a versatile technique for a large range of applications, but its intrinsically low sensitivity poses significant difficulties in analyzing mass- and volume-limited samples. The combination of microfabrication technology and MACS addresses several well-known NMR issues in a concerted manner for the first time: (i) reproducible wafer-scale fabrication of the first-in-kind on-chip LC microresonator for inductive coupling of the NMR signal and reliable exploitation of MACS capabilities; (ii) improving the sensitivity and the spectral resolution by simultaneous spinning the detection microcoil together with the sample at the “magic angle” of 54.74° with respect to the direction of the magnetic field (magic angle spinning – MAS), accompanied by the wireless signal transmission between the microcoil and the primary circuit of the NMR spectrometer; (iii) given the high spinning rates (tens of kHz) involved in the MAS methodology, the microfabricated inserts exhibit a clear kinematic advantage over their previously demonstrated counterparts due to the inherent capability to produce small radius cylindrical geometries, thus tremendously reducing the mechanical stress and tearing forces on the sample. In order to demonstrate the versatility of the microfabrication technology, we have designed MACS probes for various Larmor frequencies (194, 500 and 700 MHz) testing several samples such as water, Drosophila pupae, adamantane solid and LiCl at different magic angle spinning speeds.
Collapse
|
37
|
Teisseyre TZ, Paulsen JL, Bajaj VS, Halpern-Manners NW, Pines A. Compressive sampling with prior information in remotely detected MRI of microfluidic devices. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2012; 216:13-20. [PMID: 22386645 DOI: 10.1016/j.jmr.2011.10.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2011] [Revised: 09/29/2011] [Accepted: 10/02/2011] [Indexed: 05/31/2023]
Abstract
The design and operation of microfluidic analytical devices depends critically on tools to probe microscale chemistry and flow dynamics. Magnetic resonance imaging (MRI) seems ideally suited to this task, but its sensitivity is compromised because the fluid-containing channels in "lab on a chip" devices occupy only a small fraction of the enclosing detector's volume; as a result, the few microfluidic applications of NMR have required custom-designed chips harboring many detectors at specific points of interest. To overcome this limitation, we have developed remotely detected microfluidic MRI, in which an MR image is stored in the phase and intensity of each analyte's NMR signal and sensitively detected by a single, volume-matched detector at the device outflow, and combined it with compressed sensing for rapid image acquisition. Here, we build upon our previous work and introduce a method that incorporates our prior knowledge of the microfluidic device geometry to further decrease acquisition times. We demonstrate its use in multidimensional velocimetric imaging of a microfluidic mixer, acquiring microscopically detailed images 128 times faster than is possible with conventional sampling. This prior information also informs our choice of sampling schedule, resulting in a scheme that is optimized for a specific flow geometry. Finally, we test our approach in synthetic data and explore potential reconstruction errors as a function of optimization and reconstruction parameters.
Collapse
Affiliation(s)
- Thomas Z Teisseyre
- Graduate Program in Bioengineering, University of California, Berkeley, CA, USA
| | | | | | | | | |
Collapse
|
38
|
Strongly hyperpolarized gas from parahydrogen by rational design of ligand-capped nanoparticles. Sci Rep 2012; 2:277. [PMID: 22355789 PMCID: PMC3282305 DOI: 10.1038/srep00277] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2011] [Accepted: 01/31/2012] [Indexed: 11/08/2022] Open
Abstract
The production of hyperpolarized fluids in continuous mode would broaden substantially the range of applications in chemistry, materials science, and biomedicine. Here we show that the rational design of a heterogeneous catalyst based on a judicious choice of metal type, nanoparticle size and surface decoration with appropriate ligands leads to highly efficient pairwise addition of dihydrogen across an unsaturated bond. This is demonstrated in a parahydrogen-induced polarization (PHIP) experiment by a 508-fold enhancement (±78) of a CH3 proton signal and a corresponding 1219-fold enhancement (±187) of a CH2 proton signal using nuclear magnetic resonance (1H-NMR). In contrast, bulk metal catalyst does not show this effect due to randomization of reacting dihydrogen. Our approach results in the largest gas-phase NMR signal enhancement by PHIP known to date. Sensitivity-enhanced NMR with this technique could be used to image microfluidic reactions in-situ, to probe nonequilibrium thermodynamics or for the study of metabolic reactions.
Collapse
|
39
|
Kong TF, Peng WK, Luong TD, Nguyen NT, Han J. Adhesive-based liquid metal radio-frequency microcoil for magnetic resonance relaxometry measurement. LAB ON A CHIP 2012; 12:287-94. [PMID: 22116258 DOI: 10.1039/c1lc20853e] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
This paper reports the fabrication and characterization of an adhesive-based liquid-metal microcoil for magnetic resonance relaxometry (MRR). Conventionally, microcoils are fabricated by various techniques such as electroplating, microcontact printing and focused ion beam milling. These techniques require considerable fabrication efforts and incur high cost. In this paper, we demonstrate a novel technique to fabricate three-dimensional multilayer liquid-metal microcoils together with the microfluidic network by lamination of dry adhesive sheets. One of the unique features of the adhesive-based technique is that the detachable sample chamber can be disposed after each experiment and the microcoil can be reused without cross-contamination multiple times. The integrated microcoil has a low direct-current (DC) resistance of 0.3 Ω and a relatively high inductance of 67.5 nH leading to a high quality factor of approximately 30 at 21.65 MHz. The microcoil was characterized for ∼0.5 T proton MRR measurements. The optimal pulse duration, amplitude, and frequency for the 90° pulse were 131 μs, -30 dB (1.56 W) and 21.6553 MHz, respectively. In addition, we used the liquid-metal microcoil to perform a parametric study on the transverse relaxation rate of human red blood cells at different hematocrit levels. The transverse relaxation rate increases quadratically with the hematocrit level. The results from the liquid-metal microcoil were verified by measurements with a conventional solenoid coil.
Collapse
Affiliation(s)
- Tian Fook Kong
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore
| | | | | | | | | |
Collapse
|
40
|
James D, Oag B, Rushworth CM, Lee JWL, Davies J, Cabral JT, Vallance C. High-sensitivity online detection for microfluidics via cavity ringdown spectroscopy. RSC Adv 2012. [DOI: 10.1039/c2ra20349a] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
|
41
|
Lundborg M, Fontana C, Widmalm G. Automatic structure determination of regular polysaccharides based solely on NMR spectroscopy. Biomacromolecules 2011; 12:3851-5. [PMID: 21955217 PMCID: PMC3215282 DOI: 10.1021/bm201169y] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2011] [Revised: 09/20/2011] [Indexed: 01/22/2023]
Abstract
The structural analysis of polysaccharides requires that the sugar components and their absolute configurations are determined. We here show that this can be performed based on NMR spectroscopy by utilizing butanolysis with (+)- and (-)-2-butanol that gives the corresponding 2-butyl glycosides with characteristic (1)H and (13)C NMR chemical shifts. The subsequent computer-assisted structural determination by CASPER can then be based solely on NMR data in a fully automatic way as shown and implemented herein. The method is additionally advantageous in that reference data only have to be prepared once and from a user's point of view only the unknown sample has to be derivatized for use in CASPER.
Collapse
Affiliation(s)
- Magnus Lundborg
- Department of Organic Chemistry,
Arrhenius Laboratory, Stockholm University, S-106 91 Stockholm, Sweden
| | - Carolina Fontana
- Department of Organic Chemistry,
Arrhenius Laboratory, Stockholm University, S-106 91 Stockholm, Sweden
| | - Göran Widmalm
- Department of Organic Chemistry,
Arrhenius Laboratory, Stockholm University, S-106 91 Stockholm, Sweden
| |
Collapse
|
42
|
Jasiński K, Młynarczyk A, Latta P, Volotovskyy V, Węglarz WP, Tomanek B. A volume microstrip RF coil for MRI microscopy. Magn Reson Imaging 2011; 30:70-7. [PMID: 22055746 DOI: 10.1016/j.mri.2011.07.010] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2011] [Revised: 06/06/2011] [Accepted: 07/06/2011] [Indexed: 11/15/2022]
Abstract
Quantitative magnetic resonance imaging (MRI) studies of small samples such as a single cell or cell clusters require application of radiofrequency (RF) coils that provide homogenous B(1) field distribution and high signal-to-noise ratio (SNR). We present a novel design of an MRI RF volume microcoil based on a microstrip structure. The coil consists of two parallel microstrip elements conducting RF currents in the opposite directions, thus creating homogenous RF field within the space between the microstrips. The construction of the microcoil is simple, efficient and cost-effective. Theoretical calculations and finite element method simulations were used to optimize the coil geometry to achieve optimal B(1) and SNR distributions within the sample and predict parameters of the coil. The theoretical calculations were confirmed with MR images of a 1-mm-diameter capillary and a plant obtained with the double microstrip RF microcoil at 11.7 T. The in-plane resolution of MR images was 24 μm × 24 μm.
Collapse
Affiliation(s)
- Krzysztof Jasiński
- Institute of Nuclear Physics, Polish Academy of Sciences, 31-342 Kraków, Poland.
| | | | | | | | | | | |
Collapse
|
43
|
Jones CJ, Larive CK. Could smaller really be better? Current and future trends in high-resolution microcoil NMR spectroscopy. Anal Bioanal Chem 2011; 402:61-8. [DOI: 10.1007/s00216-011-5330-7] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2011] [Revised: 08/02/2011] [Accepted: 08/06/2011] [Indexed: 11/28/2022]
|
44
|
Hartman RL, McMullen JP, Jensen KF. Pro und kontra Strömungsreaktoren in der Synthese. Angew Chem Int Ed Engl 2011. [DOI: 10.1002/ange.201004637] [Citation(s) in RCA: 151] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
45
|
Hartman RL, McMullen JP, Jensen KF. Deciding whether to go with the flow: evaluating the merits of flow reactors for synthesis. Angew Chem Int Ed Engl 2011; 50:7502-19. [PMID: 21710673 DOI: 10.1002/anie.201004637] [Citation(s) in RCA: 651] [Impact Index Per Article: 46.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2010] [Indexed: 11/06/2022]
Abstract
The fine chemicals and pharmaceutical industries are transforming how their products are manufactured, where economically favorable, from traditional batchwise processes to continuous flow. This evolution is impacting synthetic chemistry on all scales-from the laboratory to full production. This Review discusses the relative merits of batch and micro flow reactors for performing synthetic chemistry in the laboratory.
Collapse
Affiliation(s)
- Ryan L Hartman
- Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, 66-350, Cambridge, MA 02139, USA
| | | | | |
Collapse
|
46
|
Abstract
The intracellular levels and spatial localizations of metabolites and peptides reflect the state of a cell and its relationship to its surrounding environment. Moreover, the amounts and dynamics of metabolites and peptides are indicative of normal or pathological cellular conditions. Here we highlight established and evolving strategies for characterizing the metabolome and peptidome of single cells. Focused studies of the chemical composition of individual cells and functionally defined groups of cells promise to provide a greater understanding of cell fate, function and homeostatic balance. Single-cell bioanalytical microanalysis has also become increasingly valuable for examining cellular heterogeneity, particularly in the fields of neuroscience, stem cell biology and developmental biology.
Collapse
Affiliation(s)
- Stanislav S. Rubakhin
- Department of Chemistry and the Beckman Institute, University of Illinois at Urbana-Champaign
| | - Elena V. Romanova
- Department of Chemistry and the Beckman Institute, University of Illinois at Urbana-Champaign
| | - Peter Nemes
- Department of Chemistry and the Beckman Institute, University of Illinois at Urbana-Champaign
| | - Jonathan V. Sweedler
- Department of Chemistry and the Beckman Institute, University of Illinois at Urbana-Champaign
| |
Collapse
|
47
|
Nanogram-scale preparation and NMR analysis for mass-limited small volatile compounds. PLoS One 2011; 6:e18178. [PMID: 21464906 PMCID: PMC3065492 DOI: 10.1371/journal.pone.0018178] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2010] [Accepted: 02/22/2011] [Indexed: 11/19/2022] Open
Abstract
Semiochemicals are often produced in infinitesimally small quantities, so their isolation requires large amounts of starting material, not only requiring significant effort in sample preparation, but also resulting in a complex mixture of compounds from which the bioactive compound needs to be purified and identified. Often, compounds cannot be unambiguously identified by their mass spectra alone, and NMR analysis is required for absolute chemical identification, further exacerbating the situation because NMR is relatively insensitive and requires large amounts of pure analyte, generally more than several micrograms. We developed an integrated approach for purification and NMR analysis of <1 µg of material. Collections from high performance preparative gas-chromatography are directly eluted with minimal NMR solvent into capillary NMR tubes. With this technique, 1H-NMR spectra were obtained on 50 ng of geranyl acetate, which served as a model compound, and reasonable H-H COSY NMR spectra were obtained from 250 ng of geranyl acetate. This simple off-line integration of preparative GC and NMR will facilitate the purification and chemical identification of novel volatile compounds, such as insect pheromones and other semiochemicals, which occur in minute (sub-nanogram), and often limited, quantities.
Collapse
|
48
|
Fratila RM, Velders AH. Small-volume nuclear magnetic resonance spectroscopy. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2011; 4:227-249. [PMID: 21391818 DOI: 10.1146/annurev-anchem-061010-114024] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Nuclear magnetic resonance (NMR) spectroscopy is one of the most information-rich analytical techniques available. However, it is also inherently insensitive, and this drawback precludes the application of NMR spectroscopy to mass- and volume-limited samples. We review a particular approach to increase the sensitivity of NMR experiments, namely the use of miniaturized coils. When the size of the coil is reduced, the sample volume can be brought down to the nanoliter range. We compare the main coil geometries (solenoidal, planar, and microslot/stripline) and discuss their applications to the analysis of mass-limited samples. We also provide an overview of the hyphenation of microcoil NMR spectroscopy to separation techniques and of the integration with lab-on-a-chip devices and microreactors.
Collapse
Affiliation(s)
- Raluca M Fratila
- MIRA Institute for Biomedical Engineering and Technical Medicine, Faculty of Science and Technology, University of Twente, 7500 AE Enschede, The Netherlands.
| | | |
Collapse
|
49
|
Bajaj VS, Paulsen J, Harel E, Pines A. Zooming in on microscopic flow by remotely detected MRI. Science 2010; 330:1078-81. [PMID: 20929729 DOI: 10.1126/science.1192313] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Magnetic resonance imaging (MRI) can elucidate the interior structure of an optically opaque object in unparalleled detail but is ultimately limited by the need to enclose the object within a detection coil; acquiring the image with increasingly smaller pixels reduces the sensitivity, because each pixel occupies a proportionately smaller fraction of the detector's volume. We developed a technique that overcomes this limitation by means of remotely detected MRI. Images of fluids flowing in channel assemblies are encoded into the phase and intensity of the constituent molecules' nuclear magnetic resonance signals and then decoded by a volume-matched detector after the fluids flow out of the sample. In combination with compressive sampling, we thus obtain microscopic images of flow and velocity distributions ~10(6) times faster than is possible with conventional MRI on this hardware. Our results illustrate the facile integration of MRI with microfluidic assays and suggest generalizations to other systems involving microscopic flow.
Collapse
Affiliation(s)
- Vikram S Bajaj
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA.
| | | | | | | |
Collapse
|
50
|
Harel E. Lab-on-a-chip detection by magnetic resonance methods. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2010; 57:293-305. [PMID: 20667402 DOI: 10.1016/j.pnmrs.2010.05.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2007] [Accepted: 05/10/2010] [Indexed: 05/29/2023]
Affiliation(s)
- Elad Harel
- The James Franck Institute, University of Chicago, 929 E. 57th Street, GCIS E028, Chicago, IL 60637, USA.
| |
Collapse
|