1
|
Jin Z, Yim W, Retout M, Housel E, Zhong W, Zhou J, Strano MS, Jokerst JV. Colorimetric sensing for translational applications: from colorants to mechanisms. Chem Soc Rev 2024; 53:7681-7741. [PMID: 38835195 PMCID: PMC11585252 DOI: 10.1039/d4cs00328d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2024]
Abstract
Colorimetric sensing offers instant reporting via visible signals. Versus labor-intensive and instrument-dependent detection methods, colorimetric sensors present advantages including short acquisition time, high throughput screening, low cost, portability, and a user-friendly approach. These advantages have driven substantial growth in colorimetric sensors, particularly in point-of-care (POC) diagnostics. Rapid progress in nanotechnology, materials science, microfluidics technology, biomarker discovery, digital technology, and signal pattern analysis has led to a variety of colorimetric reagents and detection mechanisms, which are fundamental to advance colorimetric sensing applications. This review first summarizes the basic components (e.g., color reagents, recognition interactions, and sampling procedures) in the design of a colorimetric sensing system. It then presents the rationale design and typical examples of POC devices, e.g., lateral flow devices, microfluidic paper-based analytical devices, and wearable sensing devices. Two highlighted colorimetric formats are discussed: combinational and activatable systems based on the sensor-array and lock-and-key mechanisms, respectively. Case discussions in colorimetric assays are organized by the analyte identities. Finally, the review presents challenges and perspectives for the design and development of colorimetric detection schemes as well as applications. The goal of this review is to provide a foundational resource for developing colorimetric systems and underscoring the colorants and mechanisms that facilitate the continuing evolution of POC sensors.
Collapse
Affiliation(s)
- Zhicheng Jin
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA 92093, USA.
| | - Wonjun Yim
- Materials Science and Engineering Program, University of California, San Diego, La Jolla, CA 92093, USA
| | - Maurice Retout
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA 92093, USA.
| | - Emily Housel
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA 92093, USA.
| | - Wenbin Zhong
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 21 Nanyang Link, Singapore 637371, Singapore
| | - Jiajing Zhou
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA 92093, USA.
| | - Michael S Strano
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jesse V Jokerst
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA 92093, USA.
- Materials Science and Engineering Program, University of California, San Diego, La Jolla, CA 92093, USA
- Department of Radiology, University of California, San Diego, La Jolla, CA 92093, USA
| |
Collapse
|
2
|
Nandhakumar P, Muñoz San Martín C, Arévalo B, Ding S, Lunker M, Vargas E, Djassemi O, Campuzano S, Wang J. Redox Cycling Amplified Electrochemical Lateral-Flow Immunoassay: Toward Decentralized Sensitive Insulin Detection. ACS Sens 2023; 8:3892-3901. [PMID: 37734056 DOI: 10.1021/acssensors.3c01445] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
While paper-based lateral-flow immunoassays (LFA) offer considerable promise for centralized diagnostic applications, the analytical capability of conventional LFA remains constrained due to the low sensitivity of its common optical detection strategy. To address these issues, we report a simple electrochemical LFA (eLFA) with nanocatalytic redox cycling for decentralized insulin detection. Simultaneous binding of insulin with detection antibodies and capture antibodies through the capillary flow at the LFA platform and signal amplification through the rapid nanocatalytic reduction of [Fe(CN)6]3- (Fe3+) with Au nanoparticles (AuNP) and ammonia-borane (AB), coupled to electrochemical redox cycling reactions involving Fe3+, AuNP, and AB on the carbon working electrode, offer higher sensitivity than conventional colorimetric LFA and enzymatic redox cycling. The resulting integrated eLFA strip allows the detection of low insulin concentrations (LOD = 12 pM) and offers considerable promise for highly sensitive decentralized assays of different biological fluids (saliva and serum) without additional pretreatment or washing steps.
Collapse
Affiliation(s)
- Ponnusamy Nandhakumar
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Cristina Muñoz San Martín
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
- Departamento de Química Analítica, Universidad Complutense, E-28040 Madrid, Spain
| | - Beatriz Arévalo
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
- Departamento de Química Analítica, Universidad Complutense, E-28040 Madrid, Spain
| | - Shichao Ding
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Mahika Lunker
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Eva Vargas
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Omeed Djassemi
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Susana Campuzano
- Departamento de Química Analítica, Universidad Complutense, E-28040 Madrid, Spain
| | - Joseph Wang
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| |
Collapse
|
3
|
Kang T, Yoo J, Choi H, Lee S, Jekarl DW, Kim Y. Performance evaluation of presepsin using a Sysmex
HISCL
‐5000 analyzer and determination of reference interval. J Clin Lab Anal 2022; 36:e24618. [PMID: 35870180 PMCID: PMC9459287 DOI: 10.1002/jcla.24618] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 07/07/2022] [Accepted: 07/08/2022] [Indexed: 12/26/2022] Open
Abstract
Background Analytical evaluation of newly developed presepsin by a Sysmex HISCL‐5000 (Sysmex, Japan) automated immune analyzer was performed. Methods For evaluation, sepsis patient samples were collected before treatment in an emergency department. Precision, linearity, limit of blank/limit of detection, method comparisons, and reference intervals were evaluated. Method comparisons were performed using a PATHFAST immune analyzer (LSI Medience Corporation, Japan). Results Precision using a 20x2x2 protocol for low (306 pg/mL) and high (1031 pg/mL) levels resulted in within‐laboratory standard deviation (95% confidence interval [CI]) and coefficient of variation (CV) %, which were as follows: 15.3 (13.1–18.7), 5.5% and 47.7, (40.5–58.1), 6.4%, respectively. Linearity using patient samples and calibrators were measured from 201 to 16,177 and 188 to 30,000 pg/mL, respectively. The regression equation was y = −23.2 + 1.008x (SE = 162.4) for low levels and y = 779.9 + 1.006x (SE = 668) for high levels. Method comparison by Passing–Bablock analysis was as follows: y = −209.77 + 1.047x (Syx = 335.3). The correlation coefficient (95% CI) was 0.869 (0.772–0.927) with statistical significance (p < 0.001). Reference intervals from 120 normal healthy subjects showed that 300 pg/mL was the cut off. Presepsin tended to show a higher value at higher ages and in males. Presepsin showed correlation with some parameters, and the correlation coefficient (p value) were as follows: hematocrit, 0.198 (0.03); eGFR (CKD‐EPI), −0.240 (0.0129); MDRD‐eGFR, −0.194 (0.048), respectively. Conclusion Presepsin measurement by HISCL‐5000 showed reliable performance. Further clinical studies are required for the diagnosis and prognosis of sepsis.
Collapse
Affiliation(s)
- Taewon Kang
- Departement of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine The Catholic University of Korea Seoul South Korea
- Research and Development Institute for In Vitro Diagnostic Medical Devices of Catholic University of Korea, College of Medicine The Catholic University of Korea Seoul South Korea
| | - Jeaeun Yoo
- Departement of Laboratory Medicine, Incheon St. Mary's Hospital, College of Medicine The Catholic University of Korea Seoul South Korea
| | - Hyunyu Choi
- Departement of Laboratory Medicine, Incheon St. Mary's Hospital, College of Medicine The Catholic University of Korea Seoul South Korea
| | - Seungok Lee
- Departement of Laboratory Medicine, Incheon St. Mary's Hospital, College of Medicine The Catholic University of Korea Seoul South Korea
| | - Dong Wook Jekarl
- Departement of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine The Catholic University of Korea Seoul South Korea
- Research and Development Institute for In Vitro Diagnostic Medical Devices of Catholic University of Korea, College of Medicine The Catholic University of Korea Seoul South Korea
| | - Yonggoo Kim
- Departement of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine The Catholic University of Korea Seoul South Korea
| |
Collapse
|
4
|
Khelifa L, Hu Y, Jiang N, Yetisen AK. Lateral flow assays for hormone detection. LAB ON A CHIP 2022; 22:2451-2475. [PMID: 35713489 DOI: 10.1039/d1lc00960e] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Endocrine diseases are the fifth most common cause of death and have a considerable impact on society given that they induce long-term morbidity in patients. For many decades, the measurement of hormones has been of great interest since this can be used to diagnose a plethora of pathological conditions. As a result, the endocrine testing market has experienced exponential growth. Several techniques have been utilised for the detection of hormones; however, they are expensive, laborious and require specialist training. Conversely, lateral flow assays (LFAs) are cheap (<£1) and rapid (<5 min) devices. LFAs typically rely on biochemical interactions between antibodies and antigens to produce coloured signals proportional to analyte concentrations, which can be visually inspected. Given their simplicity, LFAs are now considered the most attractive point-of-care device in medicine. However, the measurement of hormones in biofluids using LFAs faces many challenges including (i) the necessity for sensitive detection methods, (ii) the need for multiplexed devices for the confirmation of a diagnosis, and (iii) difficulties in sample preparation and pre-concentration. As such, most hormone LFAs remain in the research phase, and the few that have been commercialised require further optimisation before they can be employed for routine use. This review summarises the basic principles underlying lateral flow technology and provides an overview of recent advances, challenges, and potential solutions for the detection of hormone biomarkers via LFAs. Finally, hormone LFA kits available on the market are presented, with a look towards future developments and trends in the field.
Collapse
Affiliation(s)
- Leena Khelifa
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK.
| | - Yubing Hu
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK.
| | - Nan Jiang
- West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China.
| | - Ali K Yetisen
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK.
| |
Collapse
|
5
|
Jekarl DW, Lee S, Kim M, Kim Y, Woo SH, Lee WJ. Procalcitonin as a prognostic marker for sepsis based on SEPSIS-3. J Clin Lab Anal 2019; 33:e22996. [PMID: 31420921 PMCID: PMC6868407 DOI: 10.1002/jcla.22996] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 07/14/2019] [Accepted: 07/16/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND The revised definition of sepsis is life-threatening organ dysfunction caused by a dysregulated host response to infection (SEPSIS-3). The objective of this study was to evaluate procalcitonin (PCT) for the diagnosis and prognosis of sepsis using SEPSIS-3. METHODS We enrolled 248 patients, who were admitted to the emergency department with suspected bacterial infection from June 2016 to February 2017. Definite bacterial infection was defined by proven culture results, and probable bacterial infection was based on diagnostic modalities other than culture. The sequential organ failure assessment (SOFA) score of 2 points or more from the baseline was diagnosed as sepsis. PCT was measured by the AFIAS-6 immunoassay system (Boditech Med Inc.) using whole blood. White blood cell (WBC), C-reactive protein (CRP), and erythrocyte sedimentation rate (ERS) were evaluated. RESULTS The final diagnosis was sepsis in 185 patients with infection of respiratory and genitourinary tract constituted 84.6%. The area under the receiver operating characteristic curve (AUROC) with 95% confidence interval (CI) was as follows: PCT, 0.682 (0.589-0.765); CRP, 0.583 (0.487-0.673); ESR, 0.540 (0.515-0.699); and WBC, 0.611 (0.455-0.633), respectively. In multivariate analysis, age, SOFA, and PCT (log scale) predicted non-survivors with an odds ratio with 95% confidence interval of 1.055 (1.008-1.105), 1.303 (1.142-1.486), and 2.004 (1.240-3.238), respectively. Among sepsis group, initial PCT was increased in non-survivor (23.2 ng/dL) compared to survivor group (8.1 ng/dL) with statistical significance (P = .005). CONCLUSIONS PCT could support and predict the unfavorable prognosis of sepsis based on SEPSIS-3, whereas diagnostic potential of PCT requires further evaluations.
Collapse
Affiliation(s)
- Dong Wook Jekarl
- Department of Laboratory Medicine, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea.,Laboratory for Development and Evaluation Center, The Catholic University of Korea, Seoul, Korea
| | - Seungok Lee
- Department of Laboratory Medicine, The Catholic University of Korea, Incheon St. Mary's Hospital, Incheon, Korea.,Department of Emergency Medicine, The Catholic University of Korea, Incheon St. Mary's Hospital, Incheon, Korea
| | - Myungshin Kim
- Department of Laboratory Medicine, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea.,Laboratory for Development and Evaluation Center, The Catholic University of Korea, Seoul, Korea
| | - Yonggoo Kim
- Department of Laboratory Medicine, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea.,Laboratory for Development and Evaluation Center, The Catholic University of Korea, Seoul, Korea
| | - Seon Hee Woo
- Department of Emergency Medicine, The Catholic University of Korea, Incheon St. Mary's Hospital, Incheon, Korea
| | - Woon Jeong Lee
- Department of Emergency Medicine, The Catholic University of Korea, Incheon St. Mary's Hospital, Incheon, Korea
| |
Collapse
|