1
|
Yamasaki K, Dantam J, Sasanuma K, Hisamura R, Mizuno Y, Hui A, Jones L. Impact of in vitro lens deposition and removal on bacterial adhesion to orthokeratology contact lenses. Cont Lens Anterior Eye 2024; 47:102104. [PMID: 38161140 DOI: 10.1016/j.clae.2023.102104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/22/2023] [Accepted: 12/11/2023] [Indexed: 01/03/2024]
Abstract
PURPOSE The purpose of this study was to explore the impact of several contact lens (CL) care solutions on the removal of proteins and lipids, and how deposit removal impacts bacterial adhesion and solution disinfection. METHODS Lysozyme and lipid deposition on three ortho-k (rigid) and two soft CL materials were evaluated using an ELISA kit and gas chromatography respectively. Bacterial adhesion to a fluorosilicone acrylate material using Pseudomonas aeruginosa with various compositions of artificial tear solutions (ATS), including with denatured proteins, was also investigated. The impact of deposition of the different formulations of ATS on biofilm formation was explored using cover slips. Finally, the lysozyme and lipid cleaning efficacy and disinfection efficacy against P. aeruginosa and Staphylococcus aureus of four different contact lens care solutions were studied using qualitative analysis. RESULTS While maximum lysozyme deposition was observed with the fluorosilicone acrylate material (327.25 ± 54.25 µg/lens), the highest amount of lipid deposition was recorded with a fluoro-siloxanyl styrene material (134.71 ± 19.87 µg/lens). Adhesion of P. aeruginosa to fluorosilicone acrylate lenses and biofilm formation on cover slips were significantly greater with the addition of denatured proteins and lipids. Of the four contact lens care solutions investigated, the solution based on povidone-iodine removed both denatured lysozyme and lipid deposits and could effectively disinfect against P. aeruginosa and S. aureus when contaminated with denatured proteins and lipids. In contrast, the peroxide-based solution was able to inhibit P. aeruginosa growth only, while the two multipurpose solutions were unable to disinfect lenses contaminated with denatured proteins and lipids. CONCLUSION Bacterial adhesion and biofilm formation is influenced by components within artificial tear solutions depositing on lenses, including denatured proteins and lipids, which also affects disinfection. The ability of different solutions to remove these deposits should be considered when selecting systems to clean and disinfect ortho-k lenses.
Collapse
Affiliation(s)
| | - Jaya Dantam
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada
| | | | | | - Yohei Mizuno
- Kobe Research Center, OPHTECS Corporation, Kobe, Japan
| | - Alex Hui
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada; School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Australia.
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada; Centre for Eye and Vision Research (CEVR), Hong Kong Special Administrative Region, Hong Kong
| |
Collapse
|
2
|
Phan CM, Wy Chan V, Drolle E, Hui A, Ngo W, Bose S, Shows A, Liang S, Sharma V, Subbaraman L, Zheng Y, Shi X, Wu J, Jones L. Evaluating the in vitro wettability and coefficient of friction of a novel and contemporary reusable silicone hydrogel contact lens materials using an in vitro blink model. Cont Lens Anterior Eye 2024; 47:102129. [PMID: 38423868 DOI: 10.1016/j.clae.2024.102129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 02/09/2024] [Accepted: 02/20/2024] [Indexed: 03/02/2024]
Abstract
PURPOSE To evaluate the in vitro wettability and coefficient of friction of a novel amphiphilic polymeric surfactant (APS), poly(oxyethylene)-co-poly(oxybutylene) (PEO-PBO) releasing silicone hydrogel (SiHy) contact lens material (serafilcon A), compared to other reusable SiHy lens materials. METHODS The release of fluorescently-labelled nitrobenzoxadiazole (NBD)-PEO-PBO was evaluated from serafilcon A over 7 days in a vial. The wettability and coefficient of friction of serafilcon A and three contemporary SiHy contact lens materials (senofilcon A; samfilcon A; comfilcon A) were evaluated using an in vitro blink model over their recommended wearing period; t = 0, 1, 7, 14 days for all lens types and t = 30 days for samfilcon A and comfilcon A (n = 4). Sessile drop contact angles were determined and in vitro non-invasive keratographic break-up time (NIKBUT) measurements were assessed on a blink model via the OCULUS Keratograph 5 M. The coefficient of friction was measured using a nano tribometer. RESULTS The relative fluorescence of NBD-PEO-PBO decreased in serafilcon A by approximately 18 % after 7 days. The amount of NBD-PEO-PBO released on day 7 was 50 % less than the amount released on day 1 (6.5±1.0 vs 3.4±0.5 µg/lens). The reduction in PEO-PBO in the lens also coincided with an increase in contact angles for serafilcon A after 7 days (p < 0.05), although there were no changes in NIKBUT or coefficient of friction (p > 0.05). The other contact lens materials had stable contact angles and NIKBUT over their recommended wearing period (p > 0.05), with the exception of samfilcon A, which had an increase in contact angle after 14 days as compared to t = 0 (p < 0.05). Senofilcon A and samfilcon A also showed an increase in coefficient of friction at 14 and 30 days, respectively, compared to their blister pack values (p < 0.05). CONCLUSION The results indicate that serafilcon A gradually depletes its reserve of PEO-PBO over 1 week, but this decrease did not significantly change the lens performance in vitro during this time frame.
Collapse
Affiliation(s)
- Chau-Minh Phan
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong, China.
| | - Vivian Wy Chan
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Elizabeth Drolle
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Alex Hui
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Australia
| | - William Ngo
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong, China
| | - Susmita Bose
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Amanda Shows
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Shuang Liang
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Vinay Sharma
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | | | - Ying Zheng
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Xinfeng Shi
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - James Wu
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong, China
| |
Collapse
|
3
|
Zhao M, Huang M, Li Z. Exploring the therapeutic potential of recombinant human lysozyme: a review on wound management system with antibacterial. Front Bioeng Biotechnol 2023; 11:1292149. [PMID: 38026866 PMCID: PMC10646323 DOI: 10.3389/fbioe.2023.1292149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 10/20/2023] [Indexed: 12/01/2023] Open
Abstract
Lysozyme, a natural antibacterial enzyme protein, possesses the ability to dissolve the cell walls of Gram-positive bacteria, demonstrating broad-spectrum antibacterial activity. Despite its significant potential in treating wound infections and promoting wound healing, its widespread clinical application has yet to be realized. Current research is primarily focused on carrier-based delivery systems for lysozyme. In this review, we discuss four delivery systems that can be employed for lysozyme in wound healing treatment, specifically hydrogels, nanofilms, electrospun fibrous membranes, and modified-lysozyme composite systems. These systems not only enhance the stability of lysozyme but also enable its controlled and sustained release at wound sites, potentially overcoming some of the challenges associated with its direct application. Lastly, we delve into the perspectives and challenges related to the use of these delivery systems, hoping to spur further research and innovation in this promising field.
Collapse
Affiliation(s)
- Meiping Zhao
- Nursing Department, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Meili Huang
- Nursing Department, Sir Run Run Shaw Hospital Affiliated to Zhejiang University School of Medicine Alar Hospital, Alar, China
| | - Zhen Li
- Emergency Department, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
4
|
Ouyang T, Su S, Deng H, Liu Y, Cui L, Rong J, Zhao J. Superhydrophilic Poly(2-hydroxyethyl methacrylate) Hydrogel with Nanosilica Covalent Coating: A Promising Contact Lens Material for Resisting Tear Protein Deposition and Bacterial Adhesion. ACS Biomater Sci Eng 2023; 9:5653-5665. [PMID: 37736672 DOI: 10.1021/acsbiomaterials.3c00856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
Tear protein deposition and bacterial adhesion are the main drawbacks of the hydrogel contact lens. In this study, we developed a novel superhydrophilic poly(2-hydroxyethyl methacrylate) (NSCC-pHEMA) hydrogel with nanosilica covalent coating by the combination of colloidal silica immersion and dehydration treatment. The infrared spectroscopy and energy dispersive X-ray spectroscopy analyses confirmed the successful formation of Si-O covalent bonding between nanosilica and pHEMA hydrogel. This coating was highly stable against powerful sonication or long-term shaking immersion treatment. Among various NSCC-pHEMA hydrogels with different colloidal silica concentrations, the 7%NSCC-pHEMA hydrogel generated a superhydrophilic micro wrinkle surface with a root-mean-square roughness of 43.10 nm, which dramatically reduced the deposition of lysozyme and bovine serum albumin by 65% and 57%, respectively, and decreased the adhesion of S. aureus and E. coli by 59% and 66%, respectively, in comparison to the pHEMA hydrogel. However, the nanosilica coating had little effect on the mechanical properties, light transmittance, oxygen permeability, and equilibrium water content of the pHEMA hydrogel. NSCC-pHEMA hydrogels were nontoxic to both mouse fibroblasts (L929) and human immortalized keratinocytes (HaCaT). Thus, the superhydrophilic NSCC-pHEMA hydrogel is a potential contact lens material for resisting tear protein deposition and bacterial adhesion.
Collapse
Affiliation(s)
- Tao Ouyang
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Shuxian Su
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Haotian Deng
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Yuying Liu
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Lishu Cui
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Jianhua Rong
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
- Engineering Research Center of Artificial Organs and Materials, Ministry of Education, Guangzhou 511436, China
| | - Jianhao Zhao
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
- Engineering Research Center of Artificial Organs and Materials, Ministry of Education, Guangzhou 511436, China
| |
Collapse
|
5
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
6
|
Abstract
Ophthalmology is the branch of medicine that deals with diseases of the eye, the organ responsible for vision, and its attachments. Biomaterials can be made with different types of materials and can replace or improve a function or an organ, specifically the eye in the case of ophthalmic biomaterials. Biomaterials are substances that interact with biological systems for a medical purpose, either as a therapeutic (treat, augment, repair, or replace a tissue function of the body) or a diagnostic agent, and have continued to improve over the years, leading to the creation of new biomaterials. With the arrival of new generations, biomaterials have succeeded in reducing complications and toxicity and improving biocompatibilities associated with older generations. With the aging population, eye problems are becoming more prevalent, and biomaterials have helped in recent years to improve or restore vision, improving the quality of life of many patients. This review focuses on the most clinically used ophthalmic biomaterials, including contact lenses, intraocular lenses, artificial tears, inlays and vitreous replacements. Tissue engineering is presented as a new tool that is able to be treat several ophthalmologic disorders.
Collapse
|
7
|
Lin X, Liu J, Zhou F, Ou Y, Rong J, Zhao J. Poly(2-hydroxyethyl methacrylate-co-quaternary ammonium salt chitosan) hydrogel: A potential contact lens material with tear protein deposition resistance and antimicrobial activity. BIOMATERIALS ADVANCES 2022; 136:212787. [PMID: 35929300 DOI: 10.1016/j.bioadv.2022.212787] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 03/17/2022] [Accepted: 04/01/2022] [Indexed: 06/15/2023]
Abstract
Tear protein deposition resistance and antimicrobial property are two challenges of conventional poly(2-hydroxyethyl methacrylate) (pHEMA) contact lenses. In this work, we developed a poly(2-hydroxyethyl methacrylate-co-quaternary ammonium salt chitosan) hydrogel, named as p(HEMA-co-mHACC) hydrogel, using acryloyl HACC (mHACC) as a macromolecular crosslinker. With increasing the acryloyl substitution degree (14-29%) or mHACC content (2-11%), the hydrogel showed an enhanced tensile strength (432-986 kPa) and Young's modulus (360-1158 kPa), a decreased elongation at break (242-84%), and an increased visible light transmittance (0-95%). At an optimal acryloyl substitution degree of 26%, with the increase of mHACC content from 2% to 11%, p(HEMA-co-mHACC) hydrogel presented a decreased water contact angle from 84.6 to 55.3 degree, an increased equilibrium water content from 38% to 45%, and an enhanced oxygen permeability from 8.5 to 13.5 barrer. Due to the enhancement in surface hydrophilicity and electropositivity, p(HEMA-co-mHACC) hydrogel remarkably reduced the deposition of lysozyme, but little affected the adsorption of BSA, depending on the hydrophilic/hydrophobic and electrostatic interactions. The antimicrobial test against Staphylococcus aureus and Escherichia coli showed that p(HEMA-co-mHACC) hydrogel presented an 8-32 times higher germicidal ability than pHEMA hydrogel, indicative of a better antimicrobial activity. The in vitro cell culture of mouse NIH3T3 fibroblasts and immortalized human keratinocytes showed that p(HEMA-co-mHACC) hydrogel was non-toxic. Thus, p(HEMA-co-mHACC) hydrogel with tear protein deposition resistance and antimicrobial activity is a potential candidate for contact lenses.
Collapse
Affiliation(s)
- Xilin Lin
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Jinqiang Liu
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Fei Zhou
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Yangtao Ou
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Jianhua Rong
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China; Engineering Research Center of Artificial Organs and Materials, Ministry of Education, Guangzhou 511436, China
| | - Jianhao Zhao
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China; Engineering Research Center of Artificial Organs and Materials, Ministry of Education, Guangzhou 511436, China.
| |
Collapse
|
8
|
Masoudi S, Willcox M. Development of an enzymatic method for the evaluation of protein deposition on contact lenses. BIOFOULING 2022; 38:84-99. [PMID: 35016572 DOI: 10.1080/08927014.2021.2019225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 12/09/2021] [Accepted: 12/10/2021] [Indexed: 06/14/2023]
Abstract
The aim of this study was to evaluate a new digestion method to quantify protein deposition on contact lenses. Four silicone hydrogel and one hydrogel contact lens material were incubated in lactoferrin, lysozyme, immunoglobulin A, and bovine serum albumin solutions at approximate physiological concentrations and temperature. Immobilized trypsin was used to digest the protein deposits from the contact lens surfaces. The total protein absorbed to lenses was extracted and digested using sequencing grade trypsin. The tryptic peptides were quantified using selected reaction monitoring mass spectrometry. The concentration of surface protein deposits was either lower than or the same as the total protein for all lens types and proteins. Immobilised trypsin can digest protein deposits from the surface of contact lenses. This ability to analyse the amount of protein at a contact lens surface may help in elucidating the effect of surface deposition on clinical outcomes during lens wear.
Collapse
Affiliation(s)
- Simin Masoudi
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
9
|
Walsh K, Jones L, Moody K. Addressing common myths and misconceptions in soft contact lens practice. Clin Exp Optom 2021; 105:459-473. [PMID: 34886744 DOI: 10.1080/08164622.2021.2003693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Advances in contact lens technology over the past 50 years since the commercialisation of the first soft lenses in 1971 have been incredible, with significant changes in contact lens materials, frequency of replacement, care systems and lens designs occurring. However, despite the widespread availability of contact lenses, penetration rates for those who need vision correction remain in the low single digits and many practitioners seem to hold on to concepts around the potential value of contact lenses that appear based in the dim and distant past and are certainly no longer valid today. This review addresses 10 common 'myths and misconceptions' around soft contact lenses using an evidence-based approach that can hopefully dispel some of these incorrect assumptions.
Collapse
Affiliation(s)
- Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.,Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong
| | - Kurt Moody
- Johnson & Johnson Vision, Jacksonville, Florida, USA
| |
Collapse
|
10
|
Efron N, Morgan PB, Nichols JJ, Walsh K, Willcox MD, Wolffsohn JS, Jones LW. All soft contact lenses are not created equal. Cont Lens Anterior Eye 2021; 45:101515. [PMID: 34583895 DOI: 10.1016/j.clae.2021.101515] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 08/11/2021] [Accepted: 09/19/2021] [Indexed: 12/13/2022]
Abstract
Soft contact lenses that have been prescribed by eye care practitioners are sometimes substituted for alternative lenses by unqualified, unregulated and sometimes even fully regulated lens suppliers, in the mistaken belief that there is essentially no difference between different soft lens types. This review considers the implications of inappropriately substituting soft contact lens types in terms of (a) lens properties: surface treatment, internal wetting agents, material, total diameter, back optic zone radius, thickness, edge profile, back surface design, optical design, power, colour (tint) and ultraviolet protection; and (b) lens usage: wearing modality (daily versus overnight wear) and replacement frequency. Potential aspects of patient dissatisfaction and adverse events when prescribed soft lenses are substituted for lenses with different properties or intended usage are considered. Substitution of 15 of the 16 lens properties considered (i.e. except for back surface design) was found to be related to at least one - and as many as six - potential sources of patient dissatisfaction and adverse ocular events. Contact lens are medical devices which are prescribed and fitted; they should never be substituted for another lens type in the absence of a new prescription further to a full finalised fitting, for the simple reason that all soft contact lenses are not created equal. A substituted lens may have properties that results in undesirable consequences in respect of vision, ocular health, comfort and cosmetic appearance, and may be incompatible with the lifestyle of the patient.
Collapse
Affiliation(s)
- Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia.
| | - Phillip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK
| | - Jason J Nichols
- School of Optometry, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Mark D Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | | | - Lyndon W Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada; Centre for Eye and Vision Research (CEVR), Hong Kong
| |
Collapse
|
11
|
Chan VWY, Phan CM, Ngo W, Jones L. Lysozyme Deposition on Contact Lenses in an In Vitro Blink-Simulation Eye Model Versus a Static Vial Deposition Model. Eye Contact Lens 2021; 47:388-393. [PMID: 33840748 DOI: 10.1097/icl.0000000000000784] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/07/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate active lysozyme deposition on daily disposable (DD) contact lenses (CL) using a novel in vitro blink model. METHODS Three conventional hydrogel DD CL materials (etafilcon A, omafilcon A, nelfilcon A) and three silicone hydrogel DD CL materials (delefilcon A, senofilcon A, somofilcon A) were tested. The device blink rate was set to 6 blinks/min with a tear flow rate of 1 μL/min using an artificial tear solution (ATS) containing lysozyme and other typical tear film components. After incubation at 2, 4, or 8 hr, lenses were removed, and lysozyme activity was measured. A separate experiment was conducted with lenses incubated in a static vial containing 480 μL of ATS. RESULTS Etafilcon A deposited significantly higher amounts of active lysozyme (402±102 μg/lens) than other lens materials after 8 hr (P<0.0001). Etafilcon A had a higher amount of active lysozyme using the blink model compared with the static vial (P=0.0435), whereas somofilcon A (P=0.0076) and senofilcon A (P=0.0019) had a higher amount of lysozyme activity in the vial compared with the blink model. CONCLUSION The blink model can be tuned to provide quantitative data that closely mimics ex vivo studies and can be used to model deposition of lysozyme on CL materials.
Collapse
Affiliation(s)
- Vivian W Y Chan
- Centre for Ocular Research and Education (CORE) (V.W.Y.C., C.-M.P., W.N., L.J.), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada ; and Centre for Eye and Vision Research (CEVR) (C.-M.P., W.N., L.J.), Hong Kong, China
| | | | | | | |
Collapse
|
12
|
Heynen M, Ng A, Martell E, Subbaraman LN, Jones L. Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems. Clin Ophthalmol 2021; 15:1727-1733. [PMID: 33935489 PMCID: PMC8079347 DOI: 10.2147/opth.s296116] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 03/17/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The amount of protein deposition on soft contact lenses and to what extent the proteins are denatured may have an impact on comfortable wearing times of contact lenses. The purpose of this study was to evaluate the effects of two lens care systems on total protein and the quantity and activity of lysozyme deposited on worn senofilcon A, silicone hydrogel contact lenses. Participants and Methods Thirty symptomatic soft contact lens wearers were enrolled into a 4-week prospective, randomized, bilateral eye, daily-wear, crossover, double-masked study. Participants were fitted with biweekly senofilcon A lenses and were assigned either a polyquaternium-1 and myristamidopropyl dimethylamine-containing system (OPTI-FREE RepleniSH) or a peroxide-based system (CLEAR CARE). After each wear period, proteins were extracted from the lenses and analyzed for total protein, total lysozyme quantity and activity. Results The use of either the peroxide-based system or the polyquaternium-1 and myristamidopropyl dimethylamine-containing system resulted in no difference (P>0.05) to the amount of total protein deposited on the lenses (6.7 ± 2.8 micrograms/lens versus 7.3 ± 2.8 micrograms/lens, respectively) or to the amount of denatured lysozyme deposits (0.8 ± 0.7 versus 0.9 ± 0.7 micrograms/lens), respectively. The total amount of lysozyme deposited on the lenses was significantly lower when using the peroxide-based system (1.3 ± 0.9 micrograms/lens) compared to the polyquaternium-1 and myristamidopropyl dimethylamine-containing system (1.7 ± 1.0 micrograms/lens) (P=0.02). Conclusion The inactivation of lysozyme deposited on senofilcon A lenses when disinfected with the peroxide-based or the polyquaternium-1 and myristamidopropyl dimethylamine-containing systems were neither statistically nor clinically significant and the overall amounts of denatured lysozyme recovered from the lenses were low (<1 microgram/lens).
Collapse
Affiliation(s)
- Miriam Heynen
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Alan Ng
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Elizabeth Martell
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lyndon Jones
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.,Centre for Eye and Vision Research (CEVR), Hong Kong Science Park, Hong Kong
| |
Collapse
|
13
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
14
|
Walther H, Lorentz H, Heynen M, Kay L, Jones LW. The Impact of Incubation Conditions on In Vitro Phosphatidylcholine Deposition on Contact Lens Materials. Optom Vis Sci 2021; 98:341-349. [PMID: 33828039 DOI: 10.1097/opx.0000000000001680] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
SIGNIFICANCE Previous in vitro measurements of contact lenses commonly investigate the impact of nonpolar tear film lipids (i.e., sterols). Polar lipids, however, are equally important stabilizing components of the tear film. This research explores and presents further knowledge about various aspects of polar lipid uptake that may impact contact lens performance. PURPOSE This study evaluated the impact of incubation time, lipid concentration, and replenishment of an artificial tear solution (ATS) on the uptake of phosphatidylcholine (PC) onto conventional hydrogel (CH) and silicone hydrogel (SH) contact lens materials. METHODS Four SHs and two CH lens materials (n = 4) were soaked in a complex ATS containing radioactive 14C-PC as a probe molecule. Phosphatidylcholine uptake was monitored at various incubation time points (1, 3, 7, 14, and 28 days), with different ATS lipid concentrations (0.5×, 1×, 2×) and with and without regular replenishment of the ATS. Phosphatidylcholine was extracted from the lenses, processed, and counted by a β counter, and accumulated PC (μg/lens) was extrapolated from standard lipid calibration curves. RESULTS All materials exhibited increasing PC deposition over time. Conventional hydrogel materials showed significantly lower PC uptake rates (P < .001) than any of the SH materials. Increasing lipid concentration in the ATS resulted in increased PC binding onto the contact lens materials (P < .001). Replenishing the ATS every other day, however, impacted the PC deposition differently, showing increased binding (P < .001) on CHs and reduced PC deposition for SH materials (P < .001). CONCLUSIONS Length of incubation, lipid concentration in the ATS, and renewal of the incubation solution all influenced the amount of PC that sorbed onto various lens materials and therefore need to be considered when conducting future in vitro deposition studies.
Collapse
Affiliation(s)
| | | | - Miriam Heynen
- Centre for Ocular Research & Education, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lise Kay
- Centre for Ocular Research & Education, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | | |
Collapse
|
15
|
Mirzapour P, McCanna DJ, Jones L. In vitro analysis of the interaction of tear film inflammatory markers with contemporary contact lens materials. Cont Lens Anterior Eye 2021; 44:101430. [PMID: 33771440 DOI: 10.1016/j.clae.2021.02.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 02/01/2021] [Accepted: 02/12/2021] [Indexed: 11/17/2022]
Abstract
PURPOSE Several clinical studies have suggested that reusable silicone hydrogel contact lens materials exhibit a two-times increased rate of corneal infiltrative events compared to reusable hydrogels. One potential factor contributing to this complication relates to the differential uptake of tear film-based pro-inflammatory cytokines. The purpose of this study was to use an in vitro assay to investigate whether four pro-inflammatory cytokines differed in their uptake onto six contemporary contact lens materials. METHODS Conventional hydrogel (etafilcon A, omafilcon A) and silicone hydrogel (balafilcon A, comfilcon A, senofilcon A, somofilcon A) contact lens materials were soaked in solutions containing pro-inflammatory cytokines IL-1β, IL-6, IL-8 and TNF-α. Samples of the soaking solutions were collected over various time points and analyzed using the Meso Scale Discovery system, which served as a measurement of cytokine uptake onto the contact lens materials. RESULTS Both conventional hydrogels (etafilcon A, omafilcon A) and two of the four silicone hydrogels tested (balafilcon A, comfilcon A), exhibited some uptake of IL-1β, IL-8 or TNF-α (p < 0.05). Senofilcon A and somofilcon A did not exhibit uptake of any of these cytokines (p > 0.05). There was no uptake of IL-6 onto any of the contact lens materials investigated (p > 0.05). CONCLUSION The contact lens materials tested did not exhibit any uptake of IL-6 and furthermore, did not exhibit more than 10 ± 3 % to 25 ± 12 % uptake of IL-1β, IL-8 or TNF-α. Numerous factors could contribute to the reported increase in corneal infiltrative events with reusable silicone hydrogel materials, however, based on these results, it appears that uptake of these four cytokines are unlikely to contribute to this finding.
Collapse
Affiliation(s)
- Parisa Mirzapour
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| | - David J McCanna
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada; Centre for Eye & Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| |
Collapse
|
16
|
Phan CM, Qiao H, Yee A, Jones L. Deposition of Fluorescently Tagged Lysozyme on Contact Lenses in a Physiological Blink Model. Eye Contact Lens 2021; 47:127-133. [PMID: 31789754 DOI: 10.1097/icl.0000000000000683] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/02/2019] [Indexed: 11/25/2022]
Abstract
PURPOSE To visualize the deposition of fluorescein isothiocyanate (FITC) lysozyme on daily disposable contact lenses (CLs) using a novel blink model. METHODS Three daily disposable conventional hydrogel CLs (etafilcon A, omafilcon A, and nelfilcon A) and three silicone hydrogel CLs (delefilcon A, senofilcon A, and somofilcon A) were evaluated in the study. The CLs were mounted onto a novel blink model and exposed to an artificial tear solution containing FITC lysozyme for 2 and 10 hr. The flow rate and blink speed were set to 1 μL/min and 6 blinks/min, respectively. After the incubation period, a 5-mm-diameter disc was punched out from the center of the lens and mounted on a microscope slide. The slides were imaged using the Zeiss 510 Meta confocal laser scanning microscope, which scanned the lens from the front to the back surface at 5-μm increments. RESULTS There was an increase in deposition of FITC lysozyme for all lens types with increasing incubation time (P<0.05), with the exception of somofilcon A, which did not show statistical significance between 2 and 10 hr (P>0.05). The conventional hydrogel CLs deposited higher amounts of FITC lysozyme than the silicone hydrogel CLs (P<0.001), with etafilcon A depositing the highest at all time points (P<0.05). Interestingly, at the 2-hr incubation time, most CLs showed a higher amount of deposition at the front surface than the back surface of the lens. In particular, etafilcon A showed preferred deposition at the front surface at all time points. CONCLUSION The results suggest that there is differential deposition at the front surface of the CL, which is exposed to the prelens tear film, compared with the back surface of the CL, which is exposed to the postlens tear film. Therefore, it may be beneficial to design CL materials with differing surface properties for the front and back surfaces of the CL to enhance interactions with the tear film and ocular surface.
Collapse
Affiliation(s)
- Chau-Minh Phan
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | | | | | | |
Collapse
|
17
|
Tran NPD, Ting CC, Lin CH, Yang MC. A Novel Approach to Increase the Oxygen Permeability of Soft Contact Lenses by Incorporating Silica Sol. Polymers (Basel) 2020; 12:polym12092087. [PMID: 32937918 PMCID: PMC7569976 DOI: 10.3390/polym12092087] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 09/07/2020] [Accepted: 09/11/2020] [Indexed: 12/04/2022] Open
Abstract
This study presents a novel approach to increase the oxygen permeability of hydrogel by the addition of silica sol. Herein, 2-hydroxyethyl methacrylate (HEMA) was copolymerized with N-vinyl-2-pyrrolidone (NVP) after mixing with silica sol. The resultant hydrogel was subject to characterizations including Fourier-transform infrared (FTIR), equilibrium water content (EWC), contact angle, optical transmittance, oxygen permeability (Dk), tensile test, anti-deposition of proteins, and cytotoxicity. The results showed that with the increase of silica content, the Dk values and Young’s moduli increased, the optical transmittance decreased slightly, whereas the EWC and contact angle, and protein deposition were not much affected. Moreover, the cytotoxicity of the resultant poly(HEMA-co-NVP)-SNPs indicated that the presence of silica sol was non-toxic and caused no effect to the growth of L929 cells. Thus, this approach increased the Dk of soft contact lenses without affecting their hydrophilicity.
Collapse
Affiliation(s)
| | | | | | - Ming-Chien Yang
- Correspondence: ; Tel.: +886-2-2737-6528; Fax: +886-2-2737-6544
| |
Collapse
|
18
|
Chang YC, Su CY, Chang CH, Fang HW, Wei Y. Correlation between Tribological Properties and the Quantified Structural Changes of Lysozyme on Poly (2-hydroxyethyl methacrylate) Contact Lens. Polymers (Basel) 2020; 12:polym12081639. [PMID: 32717989 PMCID: PMC7464607 DOI: 10.3390/polym12081639] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 07/17/2020] [Accepted: 07/17/2020] [Indexed: 12/23/2022] Open
Abstract
The ocular discomfort is the leading cause of contact lens wear discontinuation. Although the tear proteins as a lubricant might improve contact lens adaptation, some in vitro studies suggested that the amount of adsorbed proteins could not simply explain the lubricating performance of adsorbed proteins. The purpose of this study was to quantify the structural changes and corresponding ocular lubricating properties of adsorbed protein on a conventional contact lens material, poly (2-hydroxyethyl methacrylate) (pHEMA). The adsorption behaviors of lysozyme on pHEMA were determined by the combined effects of protein–surface and protein–protein interactions. Lysozyme, the most abundant protein in tear, was first adsorbed onto the pHEMA surface under widely varying protein solution concentrations to saturate the surface, with the areal density of the adsorbed protein presenting different protein–protein effects within the layer. These values were correlated with the measured secondary structures, and corresponding friction coefficient of the adsorbed and protein covered lens surface, respectively. The decreased friction coefficient value was an indicator of the lubricated surfaces with improved adaptation. Our results indicate that the protein–protein effects help stabilize the structure of adsorbed lysozyme on pHEMA with the raised friction coefficient measured critical for the innovation of contact lens material designs with improved adaptation.
Collapse
Affiliation(s)
- You-Cheng Chang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
| | - Chen-Ying Su
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
| | - Chia-Hua Chang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
| | - Hsu-Wei Fang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, No. 35, Keyan Road, Zhunan Town, Miaoli County 35053, Taiwan
- Correspondence: (H.-W.F.); (Y.W.)
| | - Yang Wei
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (Y.-C.C.); (C.-Y.S.); (C.-H.C.)
- Correspondence: (H.-W.F.); (Y.W.)
| |
Collapse
|
19
|
Omali NB, Subbaraman LN, Heynen M, Lada M, Canavan K, Fadli Z, Ngo W, Jones L. Lipid deposition on contact lenses in symptomatic and asymptomatic contact lens wearers. Cont Lens Anterior Eye 2020; 44:56-61. [PMID: 32466858 DOI: 10.1016/j.clae.2020.05.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 05/08/2020] [Accepted: 05/11/2020] [Indexed: 11/18/2022]
Abstract
PURPOSE Lipid deposition on contact lenses (CL) has traditionally been believed to reduce comfort during CL wear. The purpose of this study was to quantify lipid deposition on CL in a group of symptomatic and asymptomatic adapted CL wearers. METHODS This was a single-masked, randomized clinical trial. Only confirmed symptomatic (comfortable lens wear time (CWT) < 8 h and a noticeable reduction in comfort over the course of the day) and asymptomatic (CWT > 10 h and minimal reduction in comfort over the course of the day) participants were recruited to participate in the study. Participants wore senofilcon A lenses in combination with a polyquaternium-based care solution (OPTI-FREE Replenish). Worn CL samples were collected on Day 14. Deposited lipid amounts from the lenses (including cholesteryl ester, cholesterol and triolein) were quantified using a liquid chromatography-mass spectrometry technique. RESULTS Lipid deposition was significantly higher in CL extracts of asymptomatic wearers compared to the symptomatic wearers for all lipid types quantified, including cholesteryl ester (2.1 ± 0.6 vs 1.6 ± 0.5 log μg/lens), cholesterol (1.5 ± 0.3 vs 1.1 ± 0.3 log μg/lens) and triolein (0.3 ± 0.2 vs 0.1 ± 0.1 log μg/lens) (all p < 0.002). The amount of cholesteryl ester deposited was greatest (p = 0.0001), followed by cholesterol, then triolein, for both the asymptomatic and symptomatic groups (both p = 0.0001). CONCLUSION This study demonstrated that the asymptomatic group deposited a significantly greater amount of lipid on their CL. Although lipid levels measured are considered low to trigger any observable clinical deposition, they may influence other clinical outcomes, particularly comfort.
Collapse
Affiliation(s)
- Negar Babaei Omali
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Miriam Heynen
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Mark Lada
- Johnson and Johnson Vision, Jacksonville, USA
| | | | - Zohra Fadli
- Johnson and Johnson Vision, Jacksonville, USA
| | - William Ngo
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada.
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
20
|
Absorption and Extraction of Inflammatory Mediators From Contact Lens Materials. Eye Contact Lens 2019; 45:340-345. [DOI: 10.1097/icl.0000000000000576] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
21
|
Tran NPD, Yang MC. Synthesis and Characterization of Silicone Contact Lenses Based on TRIS-DMA-NVP-HEMA Hydrogels. Polymers (Basel) 2019; 11:polym11060944. [PMID: 31159172 PMCID: PMC6630243 DOI: 10.3390/polym11060944] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 05/25/2019] [Accepted: 05/29/2019] [Indexed: 11/24/2022] Open
Abstract
In this study, silicone-based hydrogel contact lenses were prepared by the polymerization of 3-(methacryloyloxy)propyltris(trimethylsiloxy)silane (TRIS), N,N-dimethylacrylamide (DMA), 1-vinyl-2-pyrrolidinone (NVP), and 2-hydroxyethylmethacrylate (HEMA). The properties of silicone hydrogel lenses were analyzed based on the methods such as equilibrium water content, oxygen permeability, optical transparency, contact angle, mechanical test, protein adsorption, and cell toxicity. The results showed that the TRIS content in all formulations increased the oxygen permeability and decreased the equilibrium water content, while both DMA and NVP contributed the hydrophilicity of the hydrogels. The maximum value of oxygen permeability was 74.9 barrers, corresponding to an equilibrium water content of 44.5% as well as a contact angle of 82°. Moreover, L929 fibroblasts grew on all these hydrogels, suggesting non-cytotoxicity. In general, the silicone hydrogels in this work exhibited good oxygen permeability, stiffness, and optical transparency as well as anti-protein adsorption. Hence, these silicone hydrogel polymers would be feasible for making contact lens.
Collapse
Affiliation(s)
- Nguyen-Phuong-Dung Tran
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
| | - Ming-Chien Yang
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
| |
Collapse
|
22
|
Synthesis and characterization of soft contact lens based on the combination of silicone nanoparticles with hydrophobic and hydrophilic monomers. JOURNAL OF POLYMER RESEARCH 2019. [DOI: 10.1007/s10965-019-1813-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
23
|
Musgrave CSA, Fang F. Contact Lens Materials: A Materials Science Perspective. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E261. [PMID: 30646633 PMCID: PMC6356913 DOI: 10.3390/ma12020261] [Citation(s) in RCA: 141] [Impact Index Per Article: 28.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 01/06/2019] [Accepted: 01/07/2019] [Indexed: 12/22/2022]
Abstract
More is demanded from ophthalmic treatments using contact lenses, which are currently used by over 125 million people around the world. Improving the material of contact lenses (CLs) is a now rapidly evolving discipline. These materials are developing alongside the advances made in related biomaterials for applications such as drug delivery. Contact lens materials are typically based on polymer- or silicone-hydrogel, with additional manufacturing technologies employed to produce the final lens. These processes are simply not enough to meet the increasing demands from CLs and the ever-increasing number of contact lens (CL) users. This review provides an advanced perspective on contact lens materials, with an emphasis on materials science employed in developing new CLs. The future trends for CL materials are to graft, incapsulate, or modify the classic CL material structure to provide new or improved functionality. In this paper, we discuss some of the fundamental material properties, present an outlook from related emerging biomaterials, and provide viewpoints of precision manufacturing in CL development.
Collapse
Affiliation(s)
| | - Fengzhou Fang
- Centre of MicroNano Manufacturing Technology (MNMT-Dublin), University College Dublin, D14 YH57 Dublin, Ireland.
- State Key Laboratory of Precision Measuring Technology and Instruments, Centre of MicroNano Manufacturing Technology (MNMT), Tianjin University, Tianjin 300072, China.
| |
Collapse
|
24
|
Improvement of the surface wettability of silicone hydrogel films by self-assembled hydroxypropyltrimethyl ammonium chloride chitosan mixed colloids. Colloids Surf A Physicochem Eng Asp 2018. [DOI: 10.1016/j.colsurfa.2018.08.073] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
25
|
Walther H, Subbaraman LN, Jones L. Novel in vitro method to determine pre-lens tear break-up time of hydrogel and silicone hydrogel contact lenses. Cont Lens Anterior Eye 2018; 42:178-184. [PMID: 30442514 DOI: 10.1016/j.clae.2018.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Revised: 10/10/2018] [Accepted: 11/04/2018] [Indexed: 10/27/2022]
Abstract
PURPOSE To develop an in vitro model to determine pre-lens non-invasive break-up time (NIBUT) and to subsequently use this method to compare the NIBUT over contemporary daily disposable (DD) contact lenses (CL). METHODS Three silicone hydrogel (SH) and two conventional hydrogel (CH) DD CLs were incubated in an artificial tear solution (ATS). A model blink cell (MBC) was utilised to mimic intermittent air exposure. CLs were repeatedly submerged for 3 seconds (s) and exposed to air for 10 s over periods of 2, 6, 12, and 16 hours (h). NIBUTs (n = 4) were determined out of the blister pack (T0) and at the end of each incubation period. RESULTS Overall, nesofilcon A showed the longest NIBUTs (p < 0.001). At T0, CHs revealed significantly longer NIBUTs (p ≤ 0.001) than SHs. After 2 h, nesofilcon A showed the longest NIBUT, however, this was only statistically significant compared with delefilcon A (p ≤ 0.001). After 6 h, nesofilcon A NIBUT was significantly longer than all other CLs (p ≤ 0.001). Etafilcon A showed a significantly longer NIBUT (p ≤ 0.001) after 12 h and delefilcon A had the longest NIBUT (p ≤ 0.001) after 16 h. Statistically significant (p ≤ 0.05) changes of NIBUT within the lens materials varied between time points. After 16 h, all CLs showed significant reductions in NIBUTs (p ≤ 0.001) in comparison to T0. CONCLUSION NIBUT values reduced gradually over time and varying levels of deposition impacted measured pre-lens NIBUTs. While NIBUT of CH materials are longer immediately out of the blister pack, after tear film exposure, the NIBUTs obtained using this methodology became very similar.
Collapse
Affiliation(s)
- Hendrik Walther
- Centre for Ocular Research & Education (CORE, formerly CCLR), School of Optometry and Vision Science, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada.
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE, formerly CCLR), School of Optometry and Vision Science, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE, formerly CCLR), School of Optometry and Vision Science, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
26
|
Depth Profile Assessment of the Early Phase Deposition of Lysozyme on Soft Contact Lens Materials Using a Novel In Vitro Eye Model. Eye Contact Lens 2018; 44 Suppl 2:S11-S18. [DOI: 10.1097/icl.0000000000000397] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
27
|
Omali NB, Subbaraman LN, Heynen M, Ng A, Coles-Brennan C, Fadli Z, Jones L. Surface versus bulk activity of lysozyme deposited on hydrogel contact lens materials in vitro. Cont Lens Anterior Eye 2018; 41:329-334. [DOI: 10.1016/j.clae.2018.03.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 12/15/2017] [Accepted: 03/18/2018] [Indexed: 01/12/2023]
|
28
|
In Vitro Effect of Lysozyme on Albumin Deposition to Hydrogel Contact Lens Materials. Optom Vis Sci 2017; 94:1047-1051. [PMID: 29040199 DOI: 10.1097/opx.0000000000001137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
SIGNIFICANCE Albumin deposition on contact lenses could be detrimental to contact lens (CL) wear because this may increase the risk of bacterial binding and reduce comfort. Lysozyme deposition on selected lens materials would reduce albumin deposition on lenses. PURPOSE This study aims to determine if lysozyme deposition on CLs could act as a barrier against subsequent albumin adsorption, using an in vitro model. METHODS Six hydrogel CL materials (etafilcon A, polymacon, nelfilcon A, omafilcon A, ocufilcon B, and nesofilcon A) were evaluated. Four CLs of each type were soaked in lysozyme solution for 16 hours at 37°C. Lysozyme-coated lenses were then placed in vials with 1.5 mL of artificial tear solution containing I-labeled albumin for 16 hours at 37°C with shaking. Four uncoated lenses of each type were used as controls. Lenses soaked in radiolabeled albumin were rinsed in a phosphate-buffered saline solution, and radioactive counts were measured directly on lenses using a gamma counter. Albumin uptake on lenses was measured using a calibration curve by plotting radioactive counts versus protein concentration. RESULTS Results are reported as mean ± SD. Lysozyme-coated etafilcon A lenses exhibited lower levels of deposited albumin than uncoated etafilcon A lenses (58 ± 12 vs. 84 ± 5 ng/lens; P < .05). There were no differences in albumin adsorption between control (uncoated) and lysozyme-coated polymacon (105 ± 10 vs. 110 ± 34 ng/lens), nelfilcon A (51 ± 7 vs. 42 ± 20 ng/lens), omafilcon A (90 ± 20 vs. 80 ± 38 ng/lens), ocufilcon B (87 ± 20 vs. 115 ± 50 ng/lens), and nesofilcon A (170 ± 29 vs. 161 ± 10 ng/lens) lens materials (P > .05). Uncoated nesofilcon A lenses deposited the highest amount of albumin when compared with other uncoated lenses (P < .05). CONCLUSIONS This study demonstrates that lysozyme deposited onto etafilcon A resists the deposition of albumin, which may potentially be beneficial to CL wearers.
Collapse
|
29
|
Samsom M, Korogiannaki M, Subbaraman LN, Sheardown H, Schmidt TA. Hyaluronan incorporation into model contact lens hydrogels as a built-in lubricant: Effect of hydrogel composition and proteoglycan 4 as a lubricant in solution. J Biomed Mater Res B Appl Biomater 2017; 106:1818-1826. [DOI: 10.1002/jbm.b.33989] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Revised: 08/11/2017] [Accepted: 08/28/2017] [Indexed: 11/12/2022]
Affiliation(s)
- Michael Samsom
- Biomedical Engineering Graduate Program; University of Calgary; Calgary Alberta Canada
| | - Myrto Korogiannaki
- Faculty of Chemical Engineering; McMaster University; Hamilton Ontario Canada
| | - Lakshman N. Subbaraman
- Centre for Contact Lens Research, School of Optometry & Vision Science; University of Waterloo; Waterloo Ontario Canada
| | - Heather Sheardown
- Faculty of Chemical Engineering; McMaster University; Hamilton Ontario Canada
| | - Tannin A. Schmidt
- Biomedical Engineering Graduate Program; University of Calgary; Calgary Alberta Canada
- Faculty of Kinesiology; University of Calgary; Calgary Alberta Canada
| |
Collapse
|
30
|
Boost M, Cho P, Wang Z. Disturbing the balance: effect of contact lens use on the ocular proteome and microbiome. Clin Exp Optom 2017; 100:459-472. [PMID: 28771841 DOI: 10.1111/cxo.12582] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2017] [Revised: 05/29/2017] [Accepted: 06/05/2017] [Indexed: 12/17/2022] Open
Abstract
Contact lens wear is a popular, convenient and effective method for vision correction. In recent years, contact lens practice has expanded to include new paradigms, including orthokeratology; however, their use is not entirely without risk, as the incidence of infection has consistently been reported to be higher in contact lens wearers. The explanations for this increased susceptibility have largely focused on physical damage, especially to the cornea, due to a combination of hypoxia, mechanical trauma, deposits and solution cytotoxicity, as well as poor compliance with care routines leading to introduction of pathogens into the ocular environment. However, in recent years, with the increasing availability and reduced cost of molecular techniques, the ocular environment has received greater attention with in-depth studies of proteins and other components. Numerous proteins were found to be present in the tears and their functions and interactions indicate that the tears are far more complex than formerly presumed. In addition, the concept of a sterile or limited microbial population on the ocular surface has been challenged by analysis of the microbiome. Ocular microbiome was not considered as one of the key sites for the Human Microbiome Project, as it was thought to be limited compared to other body sites. This was proven to be fallacious, as a wide variety of micro-organisms were identified in the analyses of human tears. Thus, the ocular environment is now recognised to be more complicated and interference with this ecological balance may lead to adverse effects. The use of contact lenses clearly changes the situation at the ocular surface, which may result in consequences which disturb the balance in the healthy eye.
Collapse
Affiliation(s)
- Maureen Boost
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong.,Squina International Centre for Infection Control, Hong Kong
| | - Pauline Cho
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong.,Squina International Centre for Infection Control, Hong Kong
| | - Zhaoran Wang
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong
| |
Collapse
|
31
|
A Review of Techniques to Measure Protein Sorption to Soft Contact Lenses. Eye Contact Lens 2017; 43:276-286. [PMID: 28198731 DOI: 10.1097/icl.0000000000000366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare and critically evaluate a variety of techniques to measure the quantity and biological activity of protein sorption to contact lenses over short time periods. METHODS A literature review was undertaken investigating the major techniques to measure protein sorption to soft contact lens materials, with specific reference to measuring protein directly on lenses using in situ, ex situ, protein structural, and biological activity techniques. RESULTS The use of in situ techniques to measure protein quantity provides excellent sensitivity, but many are not directly applicable to contact lenses. Many ex situ techniques struggle to measure all sorbed proteins, and these measurements can have significant signal interference from the lens materials themselves. Techniques measuring the secondary and tertiary structures of sorbed proteins have exhibited only limited success. CONCLUSIONS There are a wide variety of techniques to measure both the amount of protein and the biological activity of protein sorbed to soft contact lens materials. To measure the mass of protein sorbed to soft contact lenses (not just thin films) over short time periods, the method of choice should be I radiolabeling. This technique is sensitive enough to measure small amounts of deposited protein, provided steps are taken to limit and measure any interaction of the iodine tracer with the materials. To measure the protein activity over short time periods, the method of choice should be to measure the biological function of sorbed proteins. This may require new methods or adaptations of existing ones.
Collapse
|
32
|
Abstract
: The tear film is a complex multilayer film consisting of various proteins, enzymes, and lipids and can express a number of biomarkers in cases of disease. The development of a contact lens sensor presents a noninvasive alternative for the detection and management of various diseases. Recent work has resulted in the commercialization of a device to monitor intraocular pressure for up to 24 h, and there are extensive efforts underway to develop a contact lens sensor capable of continuous glucose tear film monitoring to manage diabetes. This clinical perspective will highlight the major developments within this field and list some of the major challenges that still need to be addressed.
Collapse
|
33
|
|
34
|
|
35
|
Improvement of the surface wettability of silicone hydrogel contact lenses via layer-by-layer self-assembly technique. Colloids Surf B Biointerfaces 2015; 136:735-43. [DOI: 10.1016/j.colsurfb.2015.10.006] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2015] [Revised: 08/27/2015] [Accepted: 10/05/2015] [Indexed: 11/23/2022]
|
36
|
Omali NB, Subbaraman LN, Coles-Brennan C, Fadli Z, Jones LW. Biological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses. Optom Vis Sci 2015; 92:750-7. [PMID: 26002002 PMCID: PMC5638422 DOI: 10.1097/opx.0000000000000615] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Accepted: 02/17/2015] [Indexed: 12/28/2022] Open
Abstract
Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel contact lenses is a complex process involving a variety of factors relating to both the protein in question and the lens material. Among tear proteins, lysozyme is a major protein that has both antibacterial and anti-inflammatory functions. Contact lens materials that have high ionicity and high water content have an increased affinity to accumulate lysozyme during wear, when compared with other soft lens materials, notably silicone hydrogel lenses. This review provides an overview of tear film proteins, with a specific focus on lysozyme, and examines various factors that influence protein deposition on contact lenses. In addition, the impact of lysozyme deposition on various ocular physiological responses and bacterial adhesion to lenses and the interaction of lysozyme with other tear proteins are reviewed. This comprehensive review suggests that deposition of lysozyme on contact lens materials may provide a number of beneficial effects during contact lens wear.
Collapse
|
37
|
Hall B, Heynen M, Jones LW, Forrest JA. Analysis of Using I125Radiolabeling for Quantifying Protein on Contact Lenses. Curr Eye Res 2015; 41:456-65. [DOI: 10.3109/02713683.2015.1031350] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
38
|
Hall B, Jones L, Forrest JA. Kinetics of Competitive Adsorption between Lysozyme and Lactoferrin on Silicone Hydrogel Contact Lenses and the Effect on Lysozyme Activity. Curr Eye Res 2014; 40:622-31. [PMID: 25251834 DOI: 10.3109/02713683.2014.946518] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To determine the effect of competitive adsorption between lysozyme and lactoferrin on silicone hydrogel contact lenses and the effect on lysozyme activity. METHODS Three commercially available silicone hydrogel contact lens materials (senofilcon A, lotrafilcon B and balafilcon A) were examined, for time points ranging from 10 s to 2 h. Total protein deposition was determined by I(125) radiolabeling of lysozyme and lactoferrin, while the activity of lysozyme was determined by a micrococcal activity assay. RESULTS Senofilcon A and balafilcon A did not show any relevant competitive adsorption between lysozyme and lactoferrin. Lotrafilcon B showed reduced protein deposition due to competitive adsorption for lactoferrin at all time points and lysozyme after 7.5 min. Co-adsorption of lactoferrin and lysozyme decreased the activity of lysozyme in solution for senofilcon A and lotrafilcon B, but co-adsorption had no effect on the surface activity of lysozyme for all lens types investigated. CONCLUSIONS Competition between lysozyme and lactoferrin is material specific. Co-adsorption of lysozyme and lactoferrin does not affect the activity of surface-bound lysozyme but can reduce the activity of subsequently desorbed lysozyme.
Collapse
Affiliation(s)
- Brad Hall
- Centre for Contact Lens Research, School of Optometry and Vision Science , Waterloo, Ontario , Canada and
| | | | | |
Collapse
|
39
|
|
40
|
Elkins CM, Qi QM, Fuller GG. Corneal cell adhesion to contact lens hydrogel materials enhanced via tear film protein deposition. PLoS One 2014; 9:e105512. [PMID: 25144576 PMCID: PMC4140805 DOI: 10.1371/journal.pone.0105512] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Accepted: 07/21/2014] [Indexed: 12/03/2022] Open
Abstract
Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the tear film protein lysozyme. PureVision balafilcon A and AirOptix lotrafilcon B lenses were soaked for five days in either phosphate buffered saline (PBS), borate buffered saline (BBS), or Sensitive Eyes Plus Saline Solution (Sensitive Eyes), either pure or in the presence of lysozyme. Treated contact lenses were then contacted to a live monolayer of corneal epithelial cells for two hours, after which the contact lens was sheared laterally. The apparent cell monolayer relaxation modulus was then used to quantify the extent of cell adhesion to the contact lens surface. For both lens types, lysozyme increased corneal cell adhesion to the contact lens, with the apparent cell monolayer relaxation modulus increasing up to an order of magnitude in the presence of protein. The magnitude of this increase depended on the identity of the soaking solution: lenses soaked in borate-buffered solutions (BBS, Sensitive Eyes) exhibited a much greater increase in cell attachment upon protein addition than those soaked in PBS. Significantly, all measurements were conducted while subjecting the cells to moderate surface pressures and shear rates, similar to those experienced by corneal cells in vivo.
Collapse
Affiliation(s)
- Claire M. Elkins
- Department of Chemical Engineering, Stanford University, Stanford, California, United States of America
- * E-mail:
| | - Qin M. Qi
- Department of Chemical Engineering, Stanford University, Stanford, California, United States of America
| | - Gerald G. Fuller
- Department of Chemical Engineering, Stanford University, Stanford, California, United States of America
| |
Collapse
|
41
|
|
42
|
Multi-site clinical assessment of Complete Revitalens MPDS in 2981 contact lens wearers across Europe and USA. Cont Lens Anterior Eye 2013; 36:289-93. [DOI: 10.1016/j.clae.2013.05.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2012] [Revised: 03/30/2013] [Accepted: 05/31/2013] [Indexed: 11/22/2022]
|
43
|
|
44
|
Abstract
PURPOSE To analyze the impact of intermittent air exposure on the in vitro deposition of two radioactive lipids on various contact lens (CL) materials, using a custom-designed model blink cell. METHODS Six different CL materials (balafilcon A, lotrafilcon B, comfilcon A, senofilcon A, etafilcon A, and omafilcon A) were mounted on the model blink cell pistons, which cycled the lenses in and out of a complex artificial tear solution (ATS) that contained a trace amount of C-cholesterol or C-phosphatidylcholine. For the short-term experiment, air-exposed lenses were continuously cycled in and out of the ATS for 10 h. Longer term incubations for 6 days were tested with lotrafilcon B and balafilcon A materials incubated in C-cholesterol ATS. The air-exposed CLs were cycled for 14 h then submerged for 10 h each day. For both experiments, the control lenses were submerged for the entire test period. After incubation, lenses were processed, and deposited masses were quantified. RESULTS Exposure to air resulted in increased amounts of cholesterol deposited by 1.6 to 4.3 fold on omafilcon A, balafilcon A, comfilcon A, and senofilcon A (p ≤ 0.03) compared with submerged lenses. No differences in deposition were observed for etafilcon A and lotrafilcon B (p > 0.05). The longer term incubation of lotrafilcon B and balafilcon A showed statistically significant increases in cholesterol deposition for both air-exposed lens materials (p < 0.02) with the increase in deposition 1.8× and 2.8×, respectively. For phosphatidylcholine, all air-exposed lenses had increased masses of deposition. These deposits were statistically greater by 1.1 to 1.6 times for omafilcon A, comfilcon A, lotrafilcon B, and senofilcon A (p < 0.04), but not statistically different for etafilcon A or balafilcon A (p > 0.05). CONCLUSIONS This study found that lipid deposition profiles are CL material dependent and that intermittent air exposure can influence the mass of lipid deposited.
Collapse
|
45
|
Ng A, Heynen M, Luensmann D, Subbaraman LN, Jones L. Impact of tear film components on the conformational state of lysozyme deposited on contact lenses. J Biomed Mater Res B Appl Biomater 2013; 101:1172-81. [PMID: 23564739 DOI: 10.1002/jbm.b.32927] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2012] [Revised: 12/06/2012] [Accepted: 01/30/2013] [Indexed: 11/07/2022]
Affiliation(s)
- Alan Ng
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Miriam Heynen
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Doerte Luensmann
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Lakshman N. Subbaraman
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| | - Lyndon Jones
- Centre for Contact Lens Research; School of Optometry and Vision Science; University of Waterloo; 200 University Avenue West Waterloo Ontario N2L 3G1 Canada
| |
Collapse
|
46
|
González-Méijome JM, da Silva AC, Neves H, Lopes-Ferreira D, Queirós A, Jorge J. Clinical performance and “ex vivo” dehydration of silicone hydrogel contact lenses with two new multipurpose solutions. Cont Lens Anterior Eye 2013; 36:86-92. [PMID: 23108008 DOI: 10.1016/j.clae.2012.10.071] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2012] [Revised: 09/05/2012] [Accepted: 10/02/2012] [Indexed: 11/24/2022]
|
47
|
Ng A, Heynen M, Luensmann D, Subbaraman LN, Jones L. Optimization of a fluorescence-based lysozyme activity assay for contact lens studies. Curr Eye Res 2013; 38:252-9. [PMID: 23373676 DOI: 10.3109/02713683.2012.757324] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To optimize a fluorescence-based lysozyme activity assay to investigate the conformational state of lysozyme in solution and to determine the impact of extraction and evaporation procedures and the possible interference of contact lens materials on lysozyme activity. METHODS The fluorescence-based lysozyme activity assay, Enzchek (Molecular Probes Inc, Eugene, OR) which utilizes fluorescently quenched Micrococcus lysodeikticus, was compared to the gold standard, classical lysozyme turbidity assay, using four differently concentrated lysozyme samples (20, 10, 5.0 and 2.0 ng/µL). Furthermore, six differently concentrated lysozyme samples (2.0, 1.0, 0.5, 0.25, 0.125 and 0.01 µg/µL) were quantified using the fluorescence-based assay in the presence of extraction solvents consisting of 0.2% and 0.02% trifluroacetic acid/acetonitrile and following evaporation procedures. RESULTS A standard curve was generated by the fluorescence-based assay ranging from 2 to 150 ng. The total active lysozyme quantified in the four lysozyme samples was not significantly different between the two assays (p > 0.05) and the concordance correlation coefficient was determined to be 0.995. However an average discrepancy between the two assays was found to be 0.474 ng, with the turbidity assay typically reporting higher active lysozyme measurements. The sensitivity of the fluorescence-based assay was higher than the classical turbidity assay when quantifying 20 ng or less active lysozyme. Following the extraction and evaporation procedures and the addition of lens extracts, the total active lysozyme recovered was 95% or greater. CONCLUSIONS In comparison to the classical turbidity assay, the fluorescence-based assay is a very sensitive method, making it a favorable technique, particularly when studying contact lens materials that deposit relatively low levels of lysozyme.
Collapse
Affiliation(s)
- Alan Ng
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | | | | | | | | |
Collapse
|
48
|
Lu C, Yoganathan RB, Kociolek M, Allen C. Hydrogel Containing Silica Shell Cross-Linked Micelles for Ocular Drug Delivery. J Pharm Sci 2013. [DOI: 10.1002/jps.23390] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
49
|
Bengani LC, Chauhan A. Extended delivery of an anionic drug by contact lens loaded with a cationic surfactant. Biomaterials 2013; 34:2814-21. [PMID: 23337326 DOI: 10.1016/j.biomaterials.2012.12.027] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2012] [Accepted: 12/22/2012] [Indexed: 11/29/2022]
Abstract
Drug eluding contact lenses can be very effective vehicles for ophthalmic drug delivery, but are incapable of releasing drug for more than a few hours. We propose to optimize the interactions of the polymer matrix of the contact lens with the hydrophobic tails of ionic surfactants to adsorb the surfactant molecules on the polymer with high packing and thus create a high surface charge. Ionic drugs can then adsorb on the charged surfactant coated surfaces with high affinity to reduce the transport rates, leading to extended release. Specifically, we show control release of an anionic drug dexamethasone 21-disodium phosphate from poly-hydroxyethyl methacrylate (p-HEMA) contact lenses by utilizing cationic surfactant (cetalkonium chloride). The partition coefficient of the drug increase exponentially with surfactant loading in the gel in at least qualitative agreement with the Debye-Hückel theory. The drug adsorbs on the surfactant covered polymer, and can also diffuse along the surface with diffusivity lower than that for the free drug, leading to a reduction in the effective diffusivity, which is the weighted combination of the free and surface diffusivities. The addition of surfactant did not impact transparency of lenses, and had additional benefits of increase in wettability and significant reduction in protein absorption. With a surfactant loading of about 10%, the drug release duration was increased from about 2 h to 50 h in 1-day ACUVUE(®) contact lenses, proving the viability of using surfactant for increasing drug release durations.
Collapse
|
50
|
|