Wunderlich C, Paoletti R, Guberman D. Optimization of the Pixel Design for Large Gamma Cameras Based on Silicon Photomultipliers. SENSORS (BASEL, SWITZERLAND) 2024; 24:6052. [PMID: 39338796 PMCID: PMC11435885 DOI: 10.3390/s24186052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 09/09/2024] [Accepted: 09/10/2024] [Indexed: 09/30/2024]
Abstract
Most single-photon emission computed tomography (SPECT) scanners employ a gamma camera with a large scintillator crystal and 50-100 large photomultiplier tubes (PMTs). In the past, we proposed that the weight, size and cost of a scanner could be reduced by replacing the PMTs with large-area silicon photomultiplier (SiPM) pixels in which commercial SiPMs are summed to reduce the number of readout channels. We studied the feasibility of that solution with a small homemade camera, but the question on how it could be implemented in a large camera remained open. In this work, we try to answer this question by performing Geant4 simulations of a full-body SPECT camera. We studied how the pixel size, shape and noise could affect its energy and spatial resolution. Our results suggest that it would be possible to obtain an intrinsic spatial resolution of a few mm FWHM and an energy resolution at 140 keV close to 10%, even if using pixels more than 20 times larger than standard commercial SiPMs of 6 × 6 mm2. We have also found that if SiPMs are distributed following a honeycomb structure, the spatial resolution is significantly better than if using square pixels distributed in a square grid.
Collapse
Affiliation(s)
- Carolin Wunderlich
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa, 56126 Pisa, Italy; (C.W.); (R.P.)
- Dipartimento di Scienze Fisiche, della Terra e dell’Ambiente, Università di Siena, 53100 Siena, Italy
| | - Riccardo Paoletti
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa, 56126 Pisa, Italy; (C.W.); (R.P.)
- Dipartimento di Scienze Fisiche, della Terra e dell’Ambiente, Università di Siena, 53100 Siena, Italy
| | - Daniel Guberman
- Departament de Física Quàntica i Astrofísica (FQA), Universitat de Barcelona (UB), 08028 Barcelona, Spain
- Institut de Ciències del Cosmos (ICCUB), Universitat de Barcelona (UB), 08028 Barcelona, Spain
| |
Collapse
|
2
|
Zeng X, Zhang Z, Li D, Huang X, Wang Z, Wang Y, Zhou W, Wang P, Zhu M, Wei Q, Gong H, Wei L. Evaluation of monolithic crystal detector with dual-ended readout utilizing multiplexing method. Phys Med Biol 2024; 69:085003. [PMID: 38484392 DOI: 10.1088/1361-6560/ad3417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 03/14/2024] [Indexed: 04/04/2024]
Abstract
Objective.Monolithic crystal detectors are increasingly being applied in positron emission tomography (PET) devices owing to their excellent depth-of-interaction (DOI) resolution capabilities and high detection efficiency. In this study, we constructed and evaluated a dual-ended readout monolithic crystal detector based on a multiplexing method.Approach.We employed two 12 × 12 silicon photomultiplier (SiPM) arrays for readout, and the signals from the 12 × 12 array were merged into 12 X and 12 Y channels using channel multiplexing. In 2D reconstruction, three methods based on the centre of gravity (COG) were compared, and the concept of thresholds was introduced. Furthermore, a light convolutional neural network (CNN) was employed for testing. To enhance depth localization resolution, we proposed a method by utilizing the mutual information from both ends of the SiPMs. The source width and collimation effect were simulated using GEANT4, and the intrinsic spatial resolution was separated from the measured values.Main results.At an operational voltage of 29 V for the SiPM, an energy resolution of approximately 12.5 % was achieved. By subtracting a 0.8 % threshold from the total energy in every channel, a 2D spatial resolution of approximately 0.90 mm full width at half maximum (FWHM) can be obtained. Furthermore, a higher level of resolution, approximately 0.80 mm FWHM, was achieved using a CNN, with some alleviation of edge effects. With the proposed DOI method, a significant 1.36 mm FWHM average DOI resolution can be achieved. Additionally, it was found that polishing and black coating on the crystal surface yielded smaller edge effects compared to a rough surface with a black coating.Significance.The introduction of a threshold in COG method and a dual-ended readout scheme can lead to excellent spatial resolution for monolithic crystal detectors, which can help to develop PET systems with both high sensitivity and high spatial resolution.
Collapse
Affiliation(s)
- Xiangtao Zeng
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Zhiming Zhang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Daowu Li
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Xianchao Huang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Zhuoran Wang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Yingjie Wang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Wei Zhou
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Peilin Wang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Meiling Zhu
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Qing Wei
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Huixing Gong
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Long Wei
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| |
Collapse
|
3
|
Lai X, Cai L, Tan JW, Zannoni EM, Odintsov B, Meng LJ. Design, Performance Evaluation, and Modeling of an Ultrahigh Resolution Detector Dedicated for Simultaneous SPECT/MRI. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022. [DOI: 10.1109/trpms.2021.3053592] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
4
|
Guberman D, Paoletti R, Rugliancich A, Wunderlich C, Passeri A. Large-Area SiPM Pixels (LASiPs): A cost-effective solution towards compact large SPECT cameras. Phys Med 2021; 82:171-184. [PMID: 33640837 DOI: 10.1016/j.ejmp.2021.01.066] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 12/11/2020] [Accepted: 01/13/2021] [Indexed: 11/30/2022] Open
Abstract
Single Photon Emission Computed Tomography (SPECT) scanners based on photomultiplier tubes (PMTs) are still largely employed in the clinical environment. A standard camera for full-body SPECT employs ~50-100 PMTs of 4-8 cm diameter and is shielded by a thick layer of lead, becoming a heavy and bulky system that can weight a few hundred kilograms. The volume, weight and cost of a camera can be significantly reduced if the PMTs are replaced by silicon photomultipliers (SiPMs). The main obstacle to use SiPMs in full-body SPECT is the limited size of their sensitive area. A few thousand channels would be needed to fill a camera if using the largest commercially-available SiPMs of 6 × 6 mm2. As a solution, we propose to use Large-Area SiPM Pixels (LASiPs), built by summing individual currents of several SiPMs into a single output. We developed a LASiP prototype that has a sensitive area 8 times larger than a 6 × 6 mm2 SiPM. We built a proof-of-concept micro-camera consisting of a 40 × 40 × 8 mm3 NaI(Tl) crystal coupled to 4 LASiPs. We evaluated its performance in a central region of 15×15 mm2, where we were able to reconstruct images of a 99mTc capillary with an intrinsic spatial resolution of ~2 mm and an energy resolution of ~11.6% at 140 keV. We used these measurements to validate Geant4 simulations of the system. This can be extended to simulate a larger camera with more and larger pixels, which could be used to optimize the implementation of LASiPs in large SPECT cameras. We provide some guidelines towards this implementation.
Collapse
Affiliation(s)
- D Guberman
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa, I-56126 Pisa, Italy; Dipartimento di Scienze Fisiche, della Terra e dell'Ambiente, Universitá di Siena, I-53100 Siena, Italy.
| | - R Paoletti
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa, I-56126 Pisa, Italy; Dipartimento di Scienze Fisiche, della Terra e dell'Ambiente, Universitá di Siena, I-53100 Siena, Italy
| | - A Rugliancich
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa, I-56126 Pisa, Italy
| | - C Wunderlich
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa, I-56126 Pisa, Italy; Dipartimento di Scienze Fisiche, della Terra e dell'Ambiente, Universitá di Siena, I-53100 Siena, Italy
| | - A Passeri
- Dipartimento di Scienze Biomediche Sperimentali e Cliniche (SBSC), Universitá di Firenze, I-50134 Florence, Italy
| |
Collapse
|
5
|
Oraiqat I, DeBruin S, Pearce R, Como C, Mikell J, Taylor C, Way J, Suarez M, Rehemtulla A, Clarke R, El Naqa I. Silicon Photomultipliers for Deep Tissue Cerenkov Emission Detection During External Beam Radiotherapy. IEEE PHOTONICS JOURNAL 2019; 11:6802316. [PMID: 33747354 PMCID: PMC7971172 DOI: 10.1109/jphot.2019.2931845] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Cerenkov Emission (CE) during external beam radiation therapy (EBRT) from a linear accelerator (Linac) has been demonstrated as a useful tool for radiotherapy quality assurance and potentially other applications for online tracking of tumors during treatment delivery. However, some of the current challenges that are impacting the potential of CE are related to the limited detection sensitivity and the lack of flexible tools to fit into an already complex treatment delivery environment. Silicon photomultiplier (SiPM) solid-state devices are new promising tools for low light detection due to their extreme sensitivity that mirrors photomultiplier tubes and yet have a form factor that is similar to silicon photodiodes, allowing for improved flexibility in device design that may help in the process of wider clinical applicability. In this work, we assess the feasibility of using SiPMs to detect CE during EBRT from a Linac and contrast their performance with commercially available silicon photodiodes (PDs). We demonstrate the feasibility of the SiPM based probes for standard dosimetry measurements. We also demonstrate that CE optical signals can be detected from tissue depths about five times greater than that for standard probes based on PDs, making our SiPM probe an enabling technology of CE measurements, particularly for deep tissue applications.
Collapse
Affiliation(s)
- Ibrahim Oraiqat
- Radiation Oncology Department, University of Michigan, Ann Arbor, MI 48109 USA
| | | | - Robin Pearce
- Biomedical Engineering Department, University of Michigan, Ann Arbor, MI 48108 USA
| | - Christopher Como
- Biomedical Engineering Department, University of Michigan, Ann Arbor, MI 48108 USA
| | - Justin Mikell
- Radiation Oncology Department, University of Michigan, Ann Arbor, MI 48109 USA
| | - Charles Taylor
- Biomedical Engineering Department, University of Michigan, Ann Arbor, MI 48108 USA
| | - John Way
- Biomedical Engineering Department, University of Michigan, Ann Arbor, MI 48108 USA
| | - Manuel Suarez
- Biomedical Engineering Department, University of Michigan, Ann Arbor, MI 48108 USA
| | - Alnawaz Rehemtulla
- Radiation Oncology Department, University of Michigan, Ann Arbor, MI 48109 USA
| | - Roy Clarke
- Endectra, LLC, Ann Arbor, MI 48109 USA
- Physics Department, University of Michigan, Ann Arbor, MI 48109 USA
| | - Issam El Naqa
- Radiation Oncology Department, University of Michigan, Ann Arbor, MI 48109 USA
| |
Collapse
|
6
|
Carminati M, Valtorta S, Belloli S, Moresco RM, Savi A, Iadanza A, Falini A, Politi LS, Cadioli M, Hutton BF, Fiorini C, Baratelli FM, Occhipinti M, Erlandsson K, Nagy K, Nyitrai Z, Czeller M, Kuhne A, Niendorf T. Validation and Performance Assessment of a Preclinical SiPM-Based SPECT/MRI Insert. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2019. [DOI: 10.1109/trpms.2019.2893377] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
7
|
Occhipinti M, Carminati M, Busca P, Butt AD, Montagnani GL, Trigilio P, Piemonte C, Ferri A, Gola A, Bukki T, Czeller M, Nyitrai Z, Papp Z, Nagy K, Fiorini C. Characterization of the Detection Module of the INSERT SPECT/MRI Clinical System. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2018. [DOI: 10.1109/trpms.2018.2864792] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
8
|
Georgiou M, Fysikopoulos E, Mikropoulos K, Fragogeorgi E, Loudos G. Characterization of "γ-Eye": a Low-Cost Benchtop Mouse-Sized Gamma Camera for Dynamic and Static Imaging Studies. Mol Imaging Biol 2018; 19:398-407. [PMID: 27730469 DOI: 10.1007/s11307-016-1011-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
PURPOSE Several preclinical imaging systems are commercially available, but their purchase and maintenance costs make them unaffordable for the majority of small- and medium-sized groups. Taking into account the needs of average users, we developed "γ-eye", a mouse-sized, benchtop γ-camera suitable for in vivo scintigraphic imaging. PROCEDURES The γ-eye is based on two position-sensitive photomultiplier tubes, coupled to a CsI(Na) pixelated scintillator and a low-energy lead collimator with parallel hexagonal holes. RESULTS The spatial resolution of the system is 2 mm at 0 mm. The energy resolution is 26 % at 140 keV and the maximum recorded sensitivity 210 cps/MBq. The system was evaluated in a proof-of-concept animal study, using three different clinical Tc-99m-labeled radiopharmaceuticals. Phantom and animal studies demonstrate its ability to provide semiquantitative results even for short scans. CONCLUSIONS Systems' performance, dimensions, and cost make γ-eye a unique solution for efficient whole-body mouse nuclear imaging.
Collapse
Affiliation(s)
| | | | - Konstantinos Mikropoulos
- Department of Biomedical Engineering, Technological Educational Institute of Athens, Athens, Greece
| | - Eirini Fragogeorgi
- National Centre for Scientific Research NCSR "Demokritos", Institute of Nuclear and Radiological Sciences and Technology, Energy and Safety, Athens, Greece
| | - George Loudos
- Department of Biomedical Engineering, Technological Educational Institute of Athens, Athens, Greece.,National Centre for Scientific Research NCSR "Demokritos", Institute of Nuclear and Radiological Sciences and Technology, Energy and Safety, Athens, Greece
| |
Collapse
|
9
|
Morozov A, Alves F, Marcos J, Martins R, Pereira L, Solovov V, Chepel V. Iterative reconstruction of SiPM light response functions in a square-shaped compact gamma camera. Phys Med Biol 2017; 62:3619-3638. [PMID: 28192280 DOI: 10.1088/1361-6560/aa6029] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Compact gamma cameras with a square-shaped monolithic scintillator crystal and an array of silicon photomultipliers (SiPMs) are actively being developed for applications in areas such as small animal imaging, cancer diagnostics and radiotracer guided surgery. Statistical methods of position reconstruction, which are potentially superior to the traditional centroid method, require accurate knowledge of the spatial response of each photomultiplier. Using both Monte Carlo simulations and experimental data obtained with a camera prototype, we show that the spatial response of all photomultipliers (light response functions) can be parameterized with axially symmetric functions obtained iteratively from flood field irradiation data. The study was performed with a camera prototype equipped with a 30 × 30 × 2 mm3 LYSO crystal and an 8 × 8 array of SiPMs for 140 keV gamma rays. The simulations demonstrate that the images, reconstructed with the maximum likelihood method using the response obtained with the iterative approach, exhibit only minor distortions: the average difference between the reconstructed and the true positions in X and Y directions does not exceed 0.2 mm in the central area of 22 × 22 mm2 and 0.4 mm at the periphery of the camera. A similar level of image distortions is shown experimentally with the camera prototype.
Collapse
Affiliation(s)
- A Morozov
- LIP-Coimbra, Department of Physics, University of Coimbra, Coimbra, Portugal. Department of Physics, University of Coimbra, Coimbra, Portugal
| | | | | | | | | | | | | |
Collapse
|
10
|
Hutton BF, Occhipinti M, Kuehne A, Máthé D, Kovács N, Waiczies H, Erlandsson K, Salvado D, Carminati M, Montagnani GL, Short SC, Ottobrini L, van Mullekom P, Piemonte C, Bukki T, Nyitrai Z, Papp Z, Nagy K, Niendorf T, de Francesco I, Fiorini C. Development of clinical simultaneous SPECT/MRI. Br J Radiol 2017; 91:20160690. [PMID: 28008775 PMCID: PMC5966197 DOI: 10.1259/bjr.20160690] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
There is increasing clinical use of combined positron emission tomography and MRI, but to date there has been no clinical system developed capable of simultaneous single-photon emission computed tomography (SPECT) and MRI. There has been development of preclinical systems, but there are several challenges faced by researchers who are developing a clinical prototype including the need for the system to be compact and stationary with MRI-compatible components. The limited work in this area is described with specific reference to the Integrated SPECT/MRI for Enhanced stratification in Radio-chemo Therapy (INSERT) project, which is at an advanced stage of developing a clinical prototype. Issues of SPECT/MRI compatibility are outlined and the clinical appeal of such a system is discussed, especially in the management of brain tumour treatment.
Collapse
Affiliation(s)
- Brian F Hutton
- 1 Institute of Nuclear Medicine, University College London (UCL), London, UK
| | - Michele Occhipinti
- 2 Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano and Instituto Nacionale di Fisica Nucleare (INFN), Milan, Italy
| | | | - Domokos Máthé
- 4 CROmed Ltd, Budapest, Hungary.,5 Department of Biophysics and Radiation Biology, Semmelweis University, Budapest, Hungary
| | | | | | - Kjell Erlandsson
- 1 Institute of Nuclear Medicine, University College London (UCL), London, UK
| | - Debora Salvado
- 1 Institute of Nuclear Medicine, University College London (UCL), London, UK
| | - Marco Carminati
- 2 Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano and Instituto Nacionale di Fisica Nucleare (INFN), Milan, Italy
| | - Giovanni L Montagnani
- 2 Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano and Instituto Nacionale di Fisica Nucleare (INFN), Milan, Italy
| | - Susan C Short
- 6 Faculty of Medicine and Health, University of Leeds, Leeds, UK
| | - Luisa Ottobrini
- 7 Department of Medical-Surgical Pathophysiology and Transplants, University of Milan, Italy.,8 Institute for Molecular Bioimaging and Physiology (IBFM), National Council of Research (CNR), Milan, Italy
| | | | | | | | | | | | | | | | - Irene de Francesco
- 12 Department of Oncology, University College London Hospitals NHS Foundation Trust, London
| | - Carlo Fiorini
- 2 Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano and Instituto Nacionale di Fisica Nucleare (INFN), Milan, Italy
| | | |
Collapse
|
11
|
Van Audenhaege K, Van Holen R, Vandenberghe S, Vanhove C, Metzler SD, Moore SC. Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging. Med Phys 2015; 42:4796-813. [PMID: 26233207 PMCID: PMC5148182 DOI: 10.1118/1.4927061] [Citation(s) in RCA: 72] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 07/07/2015] [Accepted: 07/08/2015] [Indexed: 01/23/2023] Open
Abstract
In single photon emission computed tomography, the choice of the collimator has a major impact on the sensitivity and resolution of the system. Traditional parallel-hole and fan-beam collimators used in clinical practice, for example, have a relatively poor sensitivity and subcentimeter spatial resolution, while in small-animal imaging, pinhole collimators are used to obtain submillimeter resolution and multiple pinholes are often combined to increase sensitivity. This paper reviews methods for production, sensitivity maximization, and task-based optimization of collimation for both clinical and preclinical imaging applications. New opportunities for improved collimation are now arising primarily because of (i) new collimator-production techniques and (ii) detectors with improved intrinsic spatial resolution that have recently become available. These new technologies are expected to impact the design of collimators in the future. The authors also discuss concepts like septal penetration, high-resolution applications, multiplexing, sampling completeness, and adaptive systems, and the authors conclude with an example of an optimization study for a parallel-hole, fan-beam, cone-beam, and multiple-pinhole collimator for different applications.
Collapse
Affiliation(s)
- Karen Van Audenhaege
- Department of Electronics and Information Systems, MEDISIP-IBiTech, Ghent University-iMinds Medical IT, De Pintelaan 185 block B/5, Ghent B-9000, Belgium
| | - Roel Van Holen
- Department of Electronics and Information Systems, MEDISIP-IBiTech, Ghent University-iMinds Medical IT, De Pintelaan 185 block B/5, Ghent B-9000, Belgium
| | - Stefaan Vandenberghe
- Department of Electronics and Information Systems, MEDISIP-IBiTech, Ghent University-iMinds Medical IT, De Pintelaan 185 block B/5, Ghent B-9000, Belgium
| | - Christian Vanhove
- Department of Electronics and Information Systems, MEDISIP-IBiTech, Ghent University-iMinds Medical IT, De Pintelaan 185 block B/5, Ghent B-9000, Belgium
| | - Scott D Metzler
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - Stephen C Moore
- Division of Nuclear Medicine, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115
| |
Collapse
|