Bratke G, Rau R, Kabbasch C, Zäske C, Maintz D, Haneder S, Große Hokamp N, Persigehl T, Siedek F, Weiss K. Speeding up the clinical routine: Compressed sensing for 2D imaging of lumbar spine disc herniation. Eur J Radiol 2021; 140:109738. [PMID: 33945923 DOI: 10.1016/j.ejrad.2021.109738] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 04/20/2021] [Accepted: 04/23/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE Increasing economic pressure and patient demands for comfort require an ever-increasing acceleration of scan times without compromising diagnostic certainty. This study tested the new acceleration technique Compressed SENSE (CS-SENSE) as well as different reconstruction methods for the lumbar spine. METHODS In this prospective study, 10 volunteers and 14 patients with lumbar disc herniation were scanned using a sagittal 2D T2 turbo spin echo (TSE) sequence applying different acceleration factors of SENSE and CS-SENSE. Gradient echo (GRE), autocalibration (CS-Auto) and TSE prescans were tested for reconstruction. Images were analysed by two readers regarding anatomical delineation, diagnostic certainty (for patients only) and image quality as well as objectively calculating the root mean square error (RMSE), structural similarity index (SSIM), SNR and CNR. The Friedman test and Chi-squared were used for ordinal, ANOVA for repeated measurements and Tukey Kramer test for continuous data. Cohen's kappawas calculated for interreader reliability. RESULTS CS-SENSE outperformed SENSE and CS-Auto regarding RMSE (e.g. CS-SENSE 1.5: 43.03 ± 11.64 versus SENSE 1.5: 80.41 ± 17.66; p = 0.0038) and SSIM as well as in the subjective rating for CS-SENSE 3 TSE. In the patient setting image quality was unchanged in all subjective criteria up to CS-SENSE 3 TSE (all p > 0.05) compared to standard T2 with 43 % less scan time while the GRE prescan only allowed a reduction of 32 %. CONCLUSION Combining a TSE prescan with CS-SENSE enables significant scan time reductions with unchanged ratings for lumbar spine disc herniation making this superior to the currently used SENSE acceleration or GRE reconstructions.
Collapse
Affiliation(s)
- Grischa Bratke
- Department of Radiology, University of Cologne, Cologne, Germany.
| | - Robert Rau
- Department of Radiology, Kantonsspital Graubünden, Chur, Switzerland
| | | | - Charlotte Zäske
- Department of Radiology, University of Cologne, Cologne, Germany
| | - David Maintz
- Department of Radiology, University of Cologne, Cologne, Germany
| | - Stefan Haneder
- Department of Radiology, University of Cologne, Cologne, Germany
| | | | | | - Florian Siedek
- Department of Radiology, University of Cologne, Cologne, Germany
| | | |
Collapse
|
2
|
Yang L, Liu Y, Kong X, Guo X, Liu X, Qi Q, Wang J. Diffusion tensor magnetic resonance imaging of the postoperative spine with metallic implants. NMR IN BIOMEDICINE 2020; 33:e4321. [PMID: 32348023 DOI: 10.1002/nbm.4321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 04/14/2020] [Accepted: 04/14/2020] [Indexed: 06/11/2023]
Abstract
There has been a growing need to understand the mechanism of development of acute spinal cord injury (SCI) and to optimize treatment. The paramagnetic nature of metallic implants has hampered the application of diffusion tensor imaging (DTI) in postsurgical SCI monitoring. We describe here a successful implementation of spinal DTI in postsurgical SCI patients. Data were acquired using a single-shot turbo-spin-echo sequence, where an extra gradient is applied before the refocusing pulse train to eliminate contributions from the non-Carr-Purcell-Meiboom-Gill components following a diffusion preparation block where a single-spin echo scheme is deployed. The DTI images were acquired in axial orientation with a 2 x 2 x 4 mm3 resolution and a total of 18 slices. Diffusion gradients were applied in six directions with b values of 0 and 600 seconds/mm2 . The whole scan took ~10 minutes. The sequence was compared with SENSE-DW-EPI and ZOOM-DW-EPI on a phantom, eight patients with either anterior or posterior titanium alloy implants, and a pork loin with a similar implant. The protocol resulted in dramatically reduced geometric distortions compared with routine imaging sequences, however, the SNR efficiency was compromised. The spinal cord signal displacement was 0.68±1.00 mm (mean±SD, n = 8) for the proposed protocol, and 5.14±3.07 and 2.82±1.60 mm for the SENSE-DW-EPI and ZOOM-DW-EPI sequences, respectively. Fiber tracking was achieved in the presence of implants, which in one case was accompanied by central spinal cord caviation. Mathematical analysis concluded that the proposed protocol would be generally applicable in the spinal cord when the titanium alloy implant is ~15 mm away (<0.5 kHz B0 field drift). The protocol described is capable of DTI in postsurgery SCI patients with metallic implants at sufficient resolution and SNR.
Collapse
Affiliation(s)
- Lian Yang
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yuan Liu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiangchuang Kong
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiaodong Guo
- Department of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiaoming Liu
- Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Qian Qi
- MSC Clinical & Technical Solutions, Philips Healthcare, Beijing, China
| | - Jiazheng Wang
- MSC Clinical & Technical Solutions, Philips Healthcare, Beijing, China
| |
Collapse
|
3
|
Kwon K, Kim D, Kim B, Park H. Unsupervised learning of a deep neural network for metal artifact correction using dual‐polarity readout gradients. Magn Reson Med 2019; 83:124-138. [DOI: 10.1002/mrm.27917] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 07/03/2019] [Accepted: 07/05/2019] [Indexed: 12/24/2022]
Affiliation(s)
- Kinam Kwon
- School of Electrical Engineering Korea Advanced Institute of Science and Technology Daejeon Republic of Korea
| | - Dongchan Kim
- College of Medicine Gachon University Incheon Republic of Korea
| | - Byungjai Kim
- School of Electrical Engineering Korea Advanced Institute of Science and Technology Daejeon Republic of Korea
| | - HyunWook Park
- School of Electrical Engineering Korea Advanced Institute of Science and Technology Daejeon Republic of Korea
| |
Collapse
|
4
|
Wiens CN, Artz NS, Jang H, McMillan AB, Koch KM, Reeder SB. Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation. Magn Reson Med 2017; 79:2156-2163. [PMID: 28833407 DOI: 10.1002/mrm.26859] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2016] [Revised: 07/05/2017] [Accepted: 07/13/2017] [Indexed: 12/21/2022]
Abstract
PURPOSE To develop a fully phase-encoded MRI method for distortion-free imaging near metallic implants, in clinically feasible acquisition times. THEORY AND METHODS An accelerated 3D fully phase-encoded acquisition with broadband excitation and ultrashort echo times is presented, which uses a broadband radiofrequency pulse to excite the entire off-resonance induced by the metallic implant. Furthermore, fully phase-encoded imaging is used to prevent distortions caused by frequency encoding, and to obtain ultrashort echo times for rapidly decaying signal. RESULTS Phantom and in vivo acquisitions were used to describe the relationship among excitation bandwidth, signal loss near metallic implants, and T1 weighting. Shorter radiofrequency pulses captured signal closer to the implant by improving spectral coverage and allowing shorter echo times, whereas longer pulses improved T1 weighting through larger maximum attainable flip angles. Comparisons of fully phase-encoded acquisition with broadband excitation and ultrashort echo times to T1 -weighted multi-acquisition with variable resonance image combination selective were performed in phantoms and subjects with metallic knee and hip prostheses. These acquisitions had similar contrast and acquisition efficiency. CONCLUSIONS Accelerated fully phase-encoded acquisitions with ultrashort echo times and broadband excitation can generate distortion free images near metallic implants in clinically feasible acquisition times. Magn Reson Med 79:2156-2163, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Curtis N Wiens
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Nathan S Artz
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Department of Diagnostic Imaging, St. Jude Children's Research Hospital, Memphis, Tennessee, USA
| | - Hyungseok Jang
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Alan B McMillan
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Kevin M Koch
- Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Scott B Reeder
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA.,Department of Emergency Medicine, University of Wisconsin, Madison, Wisconsin, USA
| |
Collapse
|
5
|
Multispectral 3D phase-encoded turbo spin-echo for imaging near metal: Limitations and possibilities demonstrated by simulations and phantom experiments. Magn Reson Imaging 2017; 39:31-43. [DOI: 10.1016/j.mri.2017.01.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2016] [Revised: 01/23/2017] [Accepted: 01/24/2017] [Indexed: 12/17/2022]
|
6
|
Wang J, Wright AJ, Hu D, Hesketh R, Brindle KM. Single shot three-dimensional pulse sequence for hyperpolarized 13 C MRI. Magn Reson Med 2017; 77:740-752. [PMID: 26916384 PMCID: PMC5297976 DOI: 10.1002/mrm.26168] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2015] [Revised: 12/24/2015] [Accepted: 01/25/2016] [Indexed: 12/25/2022]
Abstract
PURPOSE Metabolic imaging with hyperpolarized 13 C-labeled cell substrates is a promising technique for imaging tissue metabolism in vivo. However, the transient nature of the hyperpolarization, and its depletion following excitation, limits the imaging time and the number of excitation pulses that can be used. We describe here a single-shot three-dimensional (3D) imaging sequence and demonstrate its capability to generate 13 C MR images in tumor-bearing mice injected with hyperpolarized [1-13 C]pyruvate. METHODS The pulse sequence acquires a stack-of-spirals at two spin echoes after a single excitation pulse and encodes the kz-dimension in an interleaved manner to enhance robustness to B0 inhomogeneity. Spectral-spatial pulses are used to acquire dynamic 3D images from selected hyperpolarized 13 C-labeled metabolites. RESULTS A nominal spatial/temporal resolution of 1.25 × 1.25 × 2.5 mm3 × 2 s was achieved in tumor images of hyperpolarized [1-13 C]pyruvate and [1-13 C]lactate acquired in vivo. Higher resolution in the z-direction, with a different k-space trajectory, was demonstrated in measurements on a thermally polarized [1-13 C]lactate phantom. CONCLUSION The pulse sequence is capable of imaging hyperpolarized 13 C-labeled substrates at relatively high spatial and temporal resolutions and is robust to moderate system imperfections. Magn Reson Med 77:740-752, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Collapse
Affiliation(s)
- Jiazheng Wang
- Cancer Research UK Cambridge InstituteUniversity of Cambridge, Li Ka Shing Centre, Robinson WayCambridgeUnited Kingdom
| | - Alan J. Wright
- Cancer Research UK Cambridge InstituteUniversity of Cambridge, Li Ka Shing Centre, Robinson WayCambridgeUnited Kingdom
| | - De‐en Hu
- Cancer Research UK Cambridge InstituteUniversity of Cambridge, Li Ka Shing Centre, Robinson WayCambridgeUnited Kingdom
| | - Richard Hesketh
- Cancer Research UK Cambridge InstituteUniversity of Cambridge, Li Ka Shing Centre, Robinson WayCambridgeUnited Kingdom
| | - Kevin M. Brindle
- Cancer Research UK Cambridge InstituteUniversity of Cambridge, Li Ka Shing Centre, Robinson WayCambridgeUnited Kingdom
- Department of BiochemistryUniversity of CambridgeTennis Court RoadCambridgeUnited Kingdom.
| |
Collapse
|
7
|
Wiens CN, Artz NS, Jang H, McMillan AB, Reeder SB. Externally calibrated parallel imaging for 3D multispectral imaging near metallic implants using broadband ultrashort echo time imaging. Magn Reson Med 2016; 77:2303-2309. [PMID: 27403613 DOI: 10.1002/mrm.26327] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2016] [Revised: 06/07/2016] [Accepted: 06/09/2016] [Indexed: 01/23/2023]
Abstract
PURPOSE To develop an externally calibrated parallel imaging technique for three-dimensional multispectral imaging (3D-MSI) in the presence of metallic implants. THEORY AND METHODS A fast, ultrashort echo time (UTE) calibration acquisition is proposed to enable externally calibrated parallel imaging techniques near metallic implants. The proposed calibration acquisition uses a broadband radiofrequency (RF) pulse to excite the off-resonance induced by the metallic implant, fully phase-encoded imaging to prevent in-plane distortions, and UTE to capture rapidly decaying signal. The performance of the externally calibrated parallel imaging reconstructions was assessed using phantoms and in vivo examples. RESULTS Phantom and in vivo comparisons to self-calibrated parallel imaging acquisitions show that significant reductions in acquisition times can be achieved using externally calibrated parallel imaging with comparable image quality. Acquisition time reductions are particularly large for fully phase-encoded methods such as spectrally resolved fully phase-encoded three-dimensional (3D) fast spin-echo (SR-FPE), in which scan time reductions of up to 8 min were obtained. CONCLUSION A fully phase-encoded acquisition with broadband excitation and UTE enabled externally calibrated parallel imaging for 3D-MSI, eliminating the need for repeated calibration regions at each frequency offset. Significant reductions in acquisition time can be achieved, particularly for fully phase-encoded methods like SR-FPE. Magn Reson Med 77:2303-2309, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Curtis N Wiens
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Nathan S Artz
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Department of Diagnostic Imaging, St. Jude Children's St. Jude Children's Research Hospital, Memphis, Tennessee, USA
| | - Hyungseok Jang
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA
| | - Alan B McMillan
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Scott B Reeder
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA.,Dept. of Emergency Medicine, University of Wisconsin, Madison, Wisconsin, USA
| |
Collapse
|
8
|
Yang ACY, Kretzler M, Sudarski S, Gulani V, Seiberlich N. Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption. Invest Radiol 2016; 51:349-64. [PMID: 27003227 PMCID: PMC4948115 DOI: 10.1097/rli.0000000000000274] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The family of sparse reconstruction techniques, including the recently introduced compressed sensing framework, has been extensively explored to reduce scan times in magnetic resonance imaging (MRI). While there are many different methods that fall under the general umbrella of sparse reconstructions, they all rely on the idea that a priori information about the sparsity of MR images can be used to reconstruct full images from undersampled data. This review describes the basic ideas behind sparse reconstruction techniques, how they could be applied to improve MRI, and the open challenges to their general adoption in a clinical setting. The fundamental principles underlying different classes of sparse reconstructions techniques are examined, and the requirements that each make on the undersampled data outlined. Applications that could potentially benefit from the accelerations that sparse reconstructions could provide are described, and clinical studies using sparse reconstructions reviewed. Lastly, technical and clinical challenges to widespread implementation of sparse reconstruction techniques, including optimization, reconstruction times, artifact appearance, and comparison with current gold standards, are discussed.
Collapse
Affiliation(s)
- Alice Chieh-Yu Yang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
| | - Madison Kretzler
- Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, USA
| | - Sonja Sudarski
- Institute for Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim - Heidelberg University, Heidelberg, Germany
| | - Vikas Gulani
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
- Department of Radiology, University Hospitals of Cleveland, Cleveland, USA
| | - Nicole Seiberlich
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
- Department of Radiology, University Hospitals of Cleveland, Cleveland, USA
| |
Collapse
|
9
|
Artz NS, Wiens CN, Smith MR, Hernando D, Samsonov A, Reeder SB. Accelerating fully phase-encoded MRI near metal using multiband radiofrequency excitation. Magn Reson Med 2016; 77:1223-1230. [PMID: 27052204 DOI: 10.1002/mrm.26209] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Revised: 02/18/2016] [Accepted: 02/18/2016] [Indexed: 11/10/2022]
Abstract
PURPOSE To develop a multiband radiofrequency (RF) excitation strategy for simultaneous excitation of multiple RF offsets to accelerate fully phase-encoded imaging near metallic prostheses. METHODS Multiband RF excitation was designed and incorporated into a spectrally resolved fully phase-encoded (SR-FPE) imaging scheme. A triband (-6, 0, 6 kHz) acquisition was compared with three separate single-band acquisitions at the corresponding RF offsets with a phantom containing the head of a hip prosthesis. In vivo multiband data with continuous spectral coverage were acquired in the knee of a healthy volunteer with the head of a hip prosthesis placed posteriorly and in a volunteer with a total knee prosthetic implant. RESULTS Phantom images acquired with triband excitation were essentially identical to the composite of three single-band excitations, but with an acceleration factor of three. In vivo multiband images of the healthy knee with adjacent metal demonstrated very good depiction of knee anatomy. In vivo images of the total knee replacement were successfully acquired, allowing visualization of native tissue with far less signal dropout than 2D-FSE. CONCLUSIONS FPE imaging with multiband excitation is feasible in the presence of extreme off-resonance. This approach can reduce scan time and/or increase off-resonance coverage, enabling in vivo FPE imaging near metallic prostheses over a broad off-resonance spectrum. Magn Reson Med 77:1223-1230, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Nathan S Artz
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Department of Diagnostic Imaging, St. Jude Children's Research Hospital, Memphis, Tennessee, USA
| | - Curtis N Wiens
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Matthew R Smith
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Diego Hernando
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Alexey Samsonov
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Scott B Reeder
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA.,Department of Emergency Medicine, University of Wisconsin, Madison, Wisconsin, USA
| |
Collapse
|