Koh CWY, Lew KS, Wibawa A, Master Z, Yeap PL, Chua CGA, Lee JCL, Tan HQ, Park SY. First clinical experience following the consensus guide for calibrating a proton stopping power ratio curve in a new proton centre. Phys Med 2024; 120:103341. [PMID: 38554639 DOI: 10.1016/j.ejmp.2024.103341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 03/07/2024] [Accepted: 03/25/2024] [Indexed: 04/02/2024] Open
Abstract
BACKGROUND AND PURPOSE This work introduces the first assessment of CT calibration following the ESTRO's consensus guidelines and validating the HLUT through the irradiation of biological material. METHODS Two electron density phantoms were scanned with two CT scanners using two CT scan energies. The stopping power ratio (SPR) and mass density (MD) HLUTs for different CT scan energies were derived using Schneider's and ESTRO's methods. The comparison metric in this work is based on the Water-Equivalent Thickness (WET) difference between the treatment planning system and biological irradiation measurement. The SPR HLUTs were compared between the two calibration methods. To assess the accuracy of using MD HLUT for dose calculation in the treatment planning system, MD vs SPR HLUT was compared. Lastly, the feasibility of using a single SPR HLUT to replace two different energy CT scans was explored. RESULTS The results show a WET difference of less than 3.5% except for the result in the Bone region between Schneider's and ESTRO's methods. Comparing MD and SPR HLUT, the results from MD HLUT show less than a 3.5% difference except for the Bone region. However, the SPR HLUT shows a lower mean absolute percentage difference as compared to MD HLUT between the measured and calculated WET difference. Lastly, it is possible to use a single SPR HLUT for two different CT scan energies since both WET differences are within 3.5%. CONCLUSION This is the first report on calibrating an HLUT following the ESTRO's guidelines. While our result shows incremental improvement in range uncertainty using the ESTRO's guideline, the prescriptional approach of the guideline does promote harmonization of CT calibration protocols between different centres.
Collapse
Affiliation(s)
| | - Kah Seng Lew
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Nanyang Technological University Singapore, Singapore
| | - Andrew Wibawa
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
| | - Zubin Master
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
| | - Ping Lin Yeap
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Department of Oncology, University of Cambridge, United Kingdom
| | | | - James Cheow Lei Lee
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Nanyang Technological University Singapore, Singapore
| | - Hong Qi Tan
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore.
| | - Sung Yong Park
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore
| |
Collapse
|
2
|
Northway SK, Vallejo BM, Liu L, Hansen EE, Tang S, Mah D, MacEwan IJ, Urbanic JJ, Chang C. A quantitative framework for patient-specific collision detection in proton therapy. J Appl Clin Med Phys 2024; 25:e14247. [PMID: 38131514 PMCID: PMC11005990 DOI: 10.1002/acm2.14247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/28/2023] [Accepted: 12/04/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND Beam modifying accessories for proton therapy often need to be placed in close proximity of the patient for optimal dosimetry. However, proton treatment units are larger in size and as a result the planned treatment geometry may not be achievable due to collisions with the patient. A framework that can accurately simulate proton treatment geometry is desired. PURPOSE A quantitative framework was developed to model patient-specific proton treatment geometry, minimize air gap, and avoid collisions. METHODS The patient's external contour is converted into the International Electrotechnique Commission (IEC) gantry coordinates following the patient's orientation and each beam's gantry and table angles. All snout components are modeled by three-dimensional (3D) geometric shapes such as columns, cuboids, and frustums. Beam-specific parameters such as isocenter coordinates, snout type and extension are used to determine if any point on the external contour protrudes into the various snout components. A 3D graphical user interface is also provided to the planner to visualize the treatment geometry. In case of a collision, the framework's analytic algorithm quantifies the maximum protrusion of the external contour into the snout components. Without a collision, the framework quantifies the minimum distance of the external contour from the snout components and renders a warning if such distance is less than 5 cm. RESULTS Three different snout designs are modeled. Examples of potential collision and its aversion by snout retraction are demonstrated. Different patient orientations, including a sitting treatment position, as well as treatment plans with multiple isocenters, are successfully modeled in the framework. Finally, the dosimetric advantage of reduced air gap enabled by this framework is demonstrated by comparing plans with standard and reduced air gaps. CONCLUSION Implementation of this framework reduces incidence of collisions in the treatment room. In addition, it enables the planners to minimize the air gap and achieve better plan dosimetry.
Collapse
Affiliation(s)
- Stephen K. Northway
- Department of Radiation Medicine and Applied SciencesUniversity of California at San DiegoLa JollaCaliforniaUSA
- California Protons Cancer Therapy CenterSan DiegoCaliforniaUSA
| | - Bailey M. Vallejo
- Department of Radiation Medicine and Applied SciencesUniversity of California at San DiegoLa JollaCaliforniaUSA
- California Protons Cancer Therapy CenterSan DiegoCaliforniaUSA
| | - Lawrence Liu
- Department of Radiation Medicine and Applied SciencesUniversity of California at San DiegoLa JollaCaliforniaUSA
- California Protons Cancer Therapy CenterSan DiegoCaliforniaUSA
| | - Emily E. Hansen
- Department of Radiation Medicine and Applied SciencesUniversity of California at San DiegoLa JollaCaliforniaUSA
- California Protons Cancer Therapy CenterSan DiegoCaliforniaUSA
| | - Shikui Tang
- Texas Center for Proton TherapyIrvingTexasUSA
| | - Dennis Mah
- ProCure Proton Therapy CenterSomersetNew JerseyUSA
| | - Iain J. MacEwan
- Department of Radiation Medicine and Applied SciencesUniversity of California at San DiegoLa JollaCaliforniaUSA
- California Protons Cancer Therapy CenterSan DiegoCaliforniaUSA
| | - James J. Urbanic
- Department of Radiation Medicine and Applied SciencesUniversity of California at San DiegoLa JollaCaliforniaUSA
- California Protons Cancer Therapy CenterSan DiegoCaliforniaUSA
| | - Chang Chang
- Department of Radiation Medicine and Applied SciencesUniversity of California at San DiegoLa JollaCaliforniaUSA
- California Protons Cancer Therapy CenterSan DiegoCaliforniaUSA
| |
Collapse
|
3
|
Fatima H, Abbas P, Alshehri SM. Balancing Innovation and Patient Care in Breast Cancer: Integrating Hypofractionated Proton Therapy With Breast Reconstruction Outcomes. Cureus 2024; 16:e58056. [PMID: 38738134 PMCID: PMC11088419 DOI: 10.7759/cureus.58056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/10/2024] [Indexed: 05/14/2024] Open
Abstract
This review aims to assess the application of hypofractionated proton therapy in breast cancer reconstruction, analyzing its advantages, challenges, and broader implications for patient care. The goal is to comprehensively understand how this innovative approach can be integrated into breast cancer treatment. Proton therapy exhibits superior target coverage and safety, reducing radiation-induced complications and sparing critical organs, but skin toxicity outcomes differ from photon therapy. Tissue expanders are vital in breast reconstruction, employing innovative planning for positive long-term outcomes and highlighting the importance of balancing cancer treatment effectiveness with cosmetic outcomes. Hypofractionated proton therapy and breast cancer reconstruction present promising innovations with notable advantages in target coverage and organ sparing. However, variations in skin toxicity outcomes and the need for a careful balance between treatment effectiveness and cosmetic outcomes underscore ongoing challenges. Future directions should focus on refining treatment protocols, optimizing patient selection criteria, and integrating emerging technologies to enhance therapeutic outcomes while minimizing adverse effects.
Collapse
Affiliation(s)
- Hadia Fatima
- Radiation Oncology Department, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, Riyadh, SAU
| | - Paras Abbas
- Oncology Department, Atomic Energy Cancer Hospital, Nuclear Medicine Oncology and Radiotherapy Institute, Islamabad, PAK
| | - Salem M Alshehri
- Radiation Oncology Department, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, Riyadh, SAU
| |
Collapse
|
4
|
Thwaites DI, Prokopovich DA, Garrett RF, Haworth A, Rosenfeld A, Ahern V. The rationale for a carbon ion radiation therapy facility in Australia. J Med Radiat Sci 2024; 71 Suppl 2:59-76. [PMID: 38061984 PMCID: PMC11011608 DOI: 10.1002/jmrs.744] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 11/17/2023] [Indexed: 04/13/2024] Open
Abstract
Australia has taken a collaborative nationally networked approach to achieve particle therapy capability. This supports the under-construction proton therapy facility in Adelaide, other potential proton centres and an under-evaluation proposal for a hybrid carbon ion and proton centre in western Sydney. A wide-ranging overview is presented of the rationale for carbon ion radiation therapy, applying observations to the case for an Australian facility and to the clinical and research potential from such a national centre.
Collapse
Affiliation(s)
- David I. Thwaites
- Institute of Medical Physics, School of PhysicsUniversity of SydneySydneyNew South WalesAustralia
- Department of Radiation OncologySydney West Radiation Oncology NetworkWestmeadNew South WalesAustralia
- Radiotherapy Research Group, Institute of Medical ResearchSt James's Hospital and University of LeedsLeedsUK
| | | | - Richard F. Garrett
- Australian Nuclear Science and Technology OrganisationLucas HeightsNew South WalesAustralia
| | - Annette Haworth
- Institute of Medical Physics, School of PhysicsUniversity of SydneySydneyNew South WalesAustralia
- Department of Radiation OncologySydney West Radiation Oncology NetworkWestmeadNew South WalesAustralia
| | - Anatoly Rosenfeld
- Centre for Medical Radiation Physics, School of PhysicsUniversity of WollongongSydneyNew South WalesAustralia
| | - Verity Ahern
- Department of Radiation OncologySydney West Radiation Oncology NetworkWestmeadNew South WalesAustralia
- Westmead Clinical School, Faculty of Medicine and HealthUniversity of SydneySydneyNew South WalesAustralia
| |
Collapse
|
5
|
Zapien-Campos B, Ahmadi Ganjeh Z, Both S, Dendooven P. Measurement of the 12C(p,n) 12N reaction cross section below 150 MeV. Phys Med Biol 2024; 69:075025. [PMID: 38382103 DOI: 10.1088/1361-6560/ad2b97] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 02/21/2024] [Indexed: 02/23/2024]
Abstract
Objective. Proton therapy currently faces challenges from clinical complications on organs-at-risk due to range uncertainties. To address this issue, positron emission tomography (PET) of the proton-induced11C and15O activity has been used to provide feedback on the proton range. However, this approach is not instantaneous due to the relatively long half-lives of these nuclides. An alternative nuclide,12N (half-life 11 ms), shows promise for real-timein vivoproton range verification. Development of12N imaging requires better knowledge of its production reaction cross section.Approach. The12C(p,n)12N reaction cross section was measured by detecting positron activity of graphite targets irradiated with 66.5, 120, and 150 MeV protons. A pulsed beam delivery with 0.7-2 × 108protons per pulse was used. The positron activity was measured during the beam-off periods using a dual-head Siemens Biograph mCT PET scanner. The12N production was determined from activity time histograms.Main results. The cross section was calculated for 11 energies, ranging from 23.5 to 147 MeV, using information on the experimental setup and beam delivery. Through a comprehensive uncertainty propagation analysis, a statistical uncertainty of 2.6%-5.8% and a systematic uncertainty of 3.3%-4.6% were achieved. Additionally, a comparison between measured and simulated scanner sensitivity showed a scaling factor of 1.25 (±3%). Despite this, there was an improvement in the precision of the cross section measurement compared to values reported by the only previous study.Significance. Short-lived12N imaging is promising for real-timein vivoverification of the proton range to reduce clinical complications in proton therapy. The verification procedure requires experimental knowledge of the12N production cross section for proton energies of clinical importance, to be incorporated in a Monte Carlo framework for12N imaging prediction. This study is the first to achieve a precise measurement of the12C(p,n)12N nuclear cross section for such proton energies.
Collapse
Affiliation(s)
- Brian Zapien-Campos
- Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Zahra Ahmadi Ganjeh
- Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Stefan Both
- Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Peter Dendooven
- Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
6
|
Han D, Zhang S, Chen S, Hooshangnejad H, Yu F, Ding K, Lin H. Enhancement of Stopping Power Ratio (SPR) Estimation Accuracy through Image-Domain Dual-Energy Computer Tomography for Pencil Beam Scanning System: A Simulation Study. Cancers (Basel) 2024; 16:467. [PMID: 38275907 PMCID: PMC10814952 DOI: 10.3390/cancers16020467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/30/2023] [Accepted: 01/08/2024] [Indexed: 01/27/2024] Open
Abstract
Our study aims to quantify the impact of spectral separation on achieved theoretical prediction accuracy of proton-stopping power when the volume discrepancy between calibration phantom and scanned object is observed. Such discrepancy can be commonly seen in our CSI pediatric patients. One of the representative image-domain DECT models is employed on a virtual phantom to derive electron density and effective atomic number for a total of 34 ICRU standard human tissues. The spectral pairs used in this study are 90 kVp/140 kVp, without and with 0.1 mm to 0.5 mm additional tin filter. The two DECT images are reconstructed via a conventional filtered back projection algorithm (FBP) on simulated noiseless projection data. The best-predicted accuracy occurs at a spectral pair of 90 kVp/140 kVp with a 0.3 mm tin filter, and the root-mean-squared average error is 0.12% for tissue substitutes. The results reveal that the selected image-domain model is sensitive to spectral pair deviation when there is a discrepancy between calibration and scanning conditions. This study suggests that an optimization process may be needed for clinically available DECT scanners to yield the best proton-stopping power estimation.
Collapse
Affiliation(s)
- Dong Han
- New York Proton Center, 225 E 126th St., New York, NY 10035, USA; (F.Y.); (H.L.)
| | | | - Sixia Chen
- Department of Mathematics and Computer Science, College of Arts and Sciences, Adelphi University, One South Avenue, Garden City, NY 11530, USA;
| | - Hamed Hooshangnejad
- Department of Radiation Oncology, Johns Hopkins University, 401 North Broadway, Suite 1440, Baltimore, MD 21231, USA; (H.H.); (K.D.)
| | - Francis Yu
- New York Proton Center, 225 E 126th St., New York, NY 10035, USA; (F.Y.); (H.L.)
| | - Kai Ding
- Department of Radiation Oncology, Johns Hopkins University, 401 North Broadway, Suite 1440, Baltimore, MD 21231, USA; (H.H.); (K.D.)
| | - Haibo Lin
- New York Proton Center, 225 E 126th St., New York, NY 10035, USA; (F.Y.); (H.L.)
| |
Collapse
|
7
|
Bonaccorsi SG, Tessonnier T, Hoeltgen L, Meixner E, Harrabi S, Hörner-Rieber J, Haberer T, Abdollahi A, Debus J, Mairani A. Exploring Helium Ions' Potential for Post-Mastectomy Left-Sided Breast Cancer Radiotherapy. Cancers (Basel) 2024; 16:410. [PMID: 38254899 PMCID: PMC10814201 DOI: 10.3390/cancers16020410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 01/04/2024] [Accepted: 01/11/2024] [Indexed: 01/24/2024] Open
Abstract
Proton therapy presents a promising modality for treating left-sided breast cancer due to its unique dose distribution. Helium ions provide increased conformality thanks to a reduced lateral scattering. Consequently, the potential clinical benefit of both techniques was explored. An explorative treatment planning study involving ten patients, previously treated with VMAT (Volumetric Modulated Arc Therapy) for 50 Gy in 25 fractions for locally advanced, node-positive breast cancer, was carried out using proton pencil beam therapy with a fixed relative biological effectiveness (RBE) of 1.1 and helium therapy with a variable RBE described by the mMKM (modified microdosimetric kinetic model). Results indicated that target coverage was improved with particle therapy for both the clinical target volume and especially the internal mammary lymph nodes compared to VMAT. Median dose value analysis revealed that proton and helium plans provided lower dose on the left anterior descending artery (LAD), heart, lungs and right breast than VMAT. Notably, helium therapy exhibited improved ipsilateral lung sparing over protons. Employing NTCP models as available in the literature, helium therapy showed a lower probability of grade ≤ 2 radiation pneumonitis (22% for photons, 5% for protons and 2% for helium ions), while both proton and helium ions reduce the probability of major coronary events with respect to VMAT.
Collapse
Affiliation(s)
| | - Thomas Tessonnier
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Line Hoeltgen
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Eva Meixner
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Semi Harrabi
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Thomas Haberer
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Amir Abdollahi
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- German Cancer Consortium (DKTK), 69120 Heidelberg, Germany
| | - Jürgen Debus
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- German Cancer Consortium (DKTK), 69120 Heidelberg, Germany
| | - Andrea Mairani
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Centro Nazionale di Adroterapia Oncologica (CNAO), 27100 Pavia, Italy
| |
Collapse
|
8
|
Taasti VT, Wohlfahrt P. From computed tomography innovation to routine clinical application in radiation oncology - A joint initiative of close collaboration. Phys Imaging Radiat Oncol 2024; 29:100550. [PMID: 38390587 PMCID: PMC10881422 DOI: 10.1016/j.phro.2024.100550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2024] Open
Affiliation(s)
- Vicki Trier Taasti
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - Patrick Wohlfahrt
- Siemens Healthineers, Varian, Cancer Therapy Imaging, Forchheim, Germany
| |
Collapse
|
9
|
Parisi A, Beltran CJ, Furutani KM. Variable RBE in proton radiotherapy: a comparative study with the predictive Mayo Clinic Florida microdosimetric kinetic model and phenomenological models of cell survival. Phys Med Biol 2023; 68:185020. [PMID: 38133518 DOI: 10.1088/1361-6560/acf43b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 08/25/2023] [Indexed: 12/23/2023]
Abstract
Objectives. (1) To examine to what extent the cell- and exposure- specific information neglected in the phenomenological proton relative biological effectiveness (RBE) models could influence the computed RBE in proton therapy. (2) To explore similarities and differences in the formalism and the results between the linear energy transfer (LET)-based phenomenological proton RBE models and the microdosimetry-based Mayo Clinic Florida microdosimetric kinetic model (MCF MKM). (3) To investigate how the relationship between the RBE and the dose-mean proton LET is affected by the proton energy spectrum and the secondary fragments.Approach. We systematically compared six selected phenomenological proton RBE models with the MCF MKM in track-segment simulations, monoenergetic proton beams in a water phantom, and two spread-out Bragg peaks. A representative comparison within vitrodata for human glioblastoma cells (U87 cell line) is also included.Main results. Marked differences were observed between the results of the phenomenological proton RBE models, as reported in previous studies. The dispersion of these models' results was found to be comparable to the spread in the MCF MKM results obtained by varying the cell-specific parameters neglected in the phenomenological models. Furthermore, while single cell-specific correlation between RBE and the dose-mean proton LET seems reasonable above 2 keVμm-1, caution is necessary at lower LET values due to the relevant contribution of secondary fragments. The comparison within vitrodata demonstrates comparable agreement between the MCF MKM predictions and the results of the phenomenological models.Significance. The study highlights the importance of considering cell-specific characteristics and detailed radiation quality information for accurate RBE calculations in proton therapy. Furthermore, these results provide confidence in the use of the MCF MKM for clonogenic survival RBE calculations in proton therapy, offering a more mechanistic approach compared to phenomenological models.
Collapse
Affiliation(s)
- Alessio Parisi
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL, United States of America
| | - Chris J Beltran
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL, United States of America
| | - Keith M Furutani
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL, United States of America
| |
Collapse
|
10
|
Cheng HL, Wang JL, Wang XY, Wu XG, Xiao JF, Wang Y, Zheng Y, Jin X, Xu Y, He LJ, Li CB, Li TX, Zheng M, Zhao ZH, He ZY, Li JZ, Li YQ, Hong R. A torus source and its application for non-primary radiation evaluation. Phys Med Biol 2023; 68:245003. [PMID: 37549670 DOI: 10.1088/1361-6560/acede7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 08/07/2023] [Indexed: 08/09/2023]
Abstract
Objective. Non-primary radiation doses to normal tissues from proton therapy may be associated with an increased risk of secondary malignancies, particularly in long-term survivors. Thus, a systematic method to evaluate if the dose level of non-primary radiation meets the IEC standard requirements is needed.Approach. Different from the traditional photon radiation therapy system, proton therapy systems are composed of several subsystems in a thick bunker. These subsystems are all possible sources of non-primary radiation threatening the patient. As a case study, 7 sources in the P-Cure synchrotron-based proton therapy system are modeled in Monte Carlo (MC) code: tandem injector, injection, synchrotron ring, extraction, beam transport line, scanning nozzle and concrete reflection/scattering. To accurately evaluate the synchrotron beam loss and non-primary dose, a new model called the torus source model is developed. Its parametric equations define the position and direction of the off-orbit particle bombardment on the torus pipe shell in the Cartesian coordinate system. Non-primary doses are finally calculated by several FLUKA simulations.Main results. The ratios of summarized non-primary doses from different sources to the planned dose of 2 Gy are all much smaller than the IEC requirements in both the 15-50 cm and 50-200 cm regions. Thus, the P-Cure synchrotron-based proton therapy system is clean and patient-friendly, and there is no need an inner shielding concrete between the accelerator and patient.Significance. Non-primary radiation dose level is a very important indicator to evaluate the quality of a PT system. This manuscript provides a feasible MC procedure for synchrotron-based proton therapy with new beam loss model. Which could help people figure out precisely whether this level complies with the IEC standard before the system put into clinical treatment. What' more, the torus source model could be widely used for bending magnets in gantries and synchrotrons to evaluate non-primary doses or other radiation doses.
Collapse
Affiliation(s)
- Han-Long Cheng
- University of Science and Technology of China, National Synchrotron Radiation Laboratory, Hefei 230029, People's Republic of China
- Sino-Israeli Healthy Alliance International Medical Technology Co., Ltd, AcceleratorLaboratory, Weifang 261000, People's Republic of China
| | - Jin-Long Wang
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Xiao-Yun Wang
- Sino-Israeli Healthy Alliance International Medical Technology Co., Ltd, AcceleratorLaboratory, Weifang 261000, People's Republic of China
| | - Xiao-Guang Wu
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Jie-Fang Xiao
- Sino-Israeli Healthy Alliance International Medical Technology Co., Ltd, AcceleratorLaboratory, Weifang 261000, People's Republic of China
| | - Yang Wang
- Sino-Israeli Healthy Alliance International Medical Technology Co., Ltd, AcceleratorLaboratory, Weifang 261000, People's Republic of China
| | - Yun Zheng
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Xiao Jin
- Department of Nuclear Safety, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Ying Xu
- Department of Radiation Source, Nuclear and Radiation Safety Center, Beijing 102401, People's Republic of China
| | - Li-Juan He
- University of Science and Technology of China, National Synchrotron Radiation Laboratory, Hefei 230029, People's Republic of China
| | - Cong-Bo Li
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Tian-Xiao Li
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Min Zheng
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Zi-Hao Zhao
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Zi-Yang He
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Jin-Ze Li
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Yun-Qiu Li
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| | - Rui Hong
- Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413, People's Republic of China
| |
Collapse
|
11
|
Asadi A, Akhavanallaf A, Hosseini SA, Vosoughi N, Zaidi H. Development and validation of an optimal GATE model for proton pencil-beam scanning delivery. Z Med Phys 2023; 33:591-600. [PMID: 36424313 PMCID: PMC10751712 DOI: 10.1016/j.zemedi.2022.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 10/14/2022] [Accepted: 10/14/2022] [Indexed: 11/23/2022]
Abstract
OBJECTIVE To develop and validate a versatile Monte Carlo (MC)-based dose calculation engine to support MC-based dose verification of treatment planning systems (TPSs) and quality assurance (QA) workflows in proton therapy. METHODS The GATE MC toolkit was used to simulate a fixed horizontal active scan-based proton beam delivery (SIEMENS IONTRIS). Within the nozzle, two primary and secondary dose monitors have been designed to enable the comparison of the accuracy of dose estimation from MC simulations with respect to physical QA measurements. The developed beam model was validated against a series of commissioning measurements using pinpoint chambers and 2D array ionization chambers (IC) in terms of lateral profiles and depth dose distributions. Furthermore, beam delivery module and treatment planning has been validated against the literature deploying various clinical test cases of the AAPM TG-119 (c-shape phantom) and a prostate patient. RESULTS MC simulations showed excellent agreement with measurements in the lateral depth-dose parameters and spread-out Bragg peak (SOBP) characteristics within a maximum relative error of 0.95 mm in range, 1.83% in entrance to peak ratio, 0.27% in mean point-to-point dose difference, and 0.32% in peak location. The mean relative absolute difference between MC simulations and measurements in terms of absorbed dose in the SOBP region was 0.93% ± 0.88%. Clinical phantom studies showed a good agreement compared to research TPS (relative error for TG-119 planning target volume PTV-D95 ∼ 1.8%; and for prostate PTV-D95 ∼ -0.6%). CONCLUSION We successfully developed a MC model for the pencil beam scanning system, which appears reliable for dose verification of the TPS in combination with QA information, prior to patient treatment.
Collapse
Affiliation(s)
- Ali Asadi
- Department of Energy Engineering, Sharif University of Technology, Tehran, Iran
| | - Azadeh Akhavanallaf
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland
| | | | - Naser Vosoughi
- Department of Energy Engineering, Sharif University of Technology, Tehran, Iran
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland; Geneva University Neurocenter, Geneva University, Geneva, Switzerland; Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands; Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark.
| |
Collapse
|
12
|
Berthold J, Pietsch J, Piplack N, Khamfongkhruea C, Thiele J, Hölscher T, Janssens G, Smeets J, Traneus E, Löck S, Stützer K, Richter C. Detectability of Anatomical Changes With Prompt-Gamma Imaging: First Systematic Evaluation of Clinical Application During Prostate-Cancer Proton Therapy. Int J Radiat Oncol Biol Phys 2023; 117:718-729. [PMID: 37160193 DOI: 10.1016/j.ijrobp.2023.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 04/02/2023] [Accepted: 05/02/2023] [Indexed: 05/11/2023]
Abstract
PURPOSE The development of online-adaptive proton therapy (PT) is essential to overcome limitations encountered by day-to-day variations of the patient's anatomy. Range verification could play an essential role in an online feedback loop for the detection of treatment deviations such as anatomical changes. Here, we present the results of the first systematic patient study regarding the detectability of anatomical changes by a prompt-gamma imaging (PGI) slit-camera system. METHODS AND MATERIALS For 15 patients with prostate cancer, PGI measurements were performed during 105 fractions (201 fields) with in-room control computed tomography (CT)acquisitions. Field-wise doses on control CT scans were manually classified as whether showing relevant or non-relevant anatomical changes. This manual classification of the treatment fields was then used to establish an automatic field-wise ground truth based on spot-wise dosimetric range shifts, which were retrieved from integrated depth-dose (IDD) profiles. To determine the detection capability of anatomical changes with PGI, spot-wise PGI-based range shifts were initially compared with corresponding dosimetric IDD range shifts. As final endpoint, the agreement of a developed field-wise PGI classification model with the field-wise ground truth was determined. Therefore, the PGI model was optimized and tested for a subcohort of 131 and 70 treatment fields, respectively. RESULTS The correlation between PGI and IDD range shifts was high, ρpearson = 0.67 (p < 0.01). Field-wise binary PGI classification resulted in an area under the curve of 0.72 and 0.80 for training and test cohorts, respectively. The model detected relevant anatomical changes in the independent test cohort, with a sensitivity and specificity of 74% and 79%, respectively. CONCLUSIONS For the first time, evidence of the detection capability of anatomical changes in prostate-cancer PT from clinically acquired PGI data is shown. This emphasizes the benefit of PGI-based range verification and demonstrates its potential for online-adaptive PT.
Collapse
Affiliation(s)
- Jonathan Berthold
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.
| | - Julian Pietsch
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Nick Piplack
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Technische Universität Dresden, Faculty of Electrical and Computer Engineering, Dresden, Germany
| | - Chirasak Khamfongkhruea
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Princess Srisavangavadhana College of Medicine, Chulabhorn Royal Academy, Bangkok, Thailand
| | - Julia Thiele
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Tobias Hölscher
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | | | | | | | - Steffen Löck
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; German Cancer Consortium (DKTK), partner site Dresden, Germany and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Kristin Stützer
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Christian Richter
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; German Cancer Consortium (DKTK), partner site Dresden, Germany and German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
13
|
Clausen M, Ruangchan S, Sotoudegan A, Resch AF, Knäusl B, Palmans H, Georg D. Small field proton irradiation for in vivo studies: Potential and limitations when adapting clinical infrastructure. Z Med Phys 2023; 33:542-551. [PMID: 36357294 PMCID: PMC10751703 DOI: 10.1016/j.zemedi.2022.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 09/22/2022] [Accepted: 10/04/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE To evaluate the dosimetric accuracy for small field proton irradiation relevant for pre-clinical in vivo studies using clinical infrastructure and technology. In this context additional beam collimation and range reduction was implemented. METHODS AND MATERIALS The clinical proton beam line employing pencil beam scanning (PBS) was adapted for the irradiation of small fields at shallow depths. Cylindrical collimators with apertures of 15, 12, 7 and 5mm as well as two different range shifter types, placed at different distances relative to the target, were tested: a bolus range shifter (BRS) attached to the collimator and a clinical nozzle mounted range shifter (CRS) placed at a distance of 72cm from the collimator. The Monte Carlo (MC) based dose calculation engine implemented in the clinical treatment planning system (TPS) was commissioned for these two additional hardware components. The study was conducted with a phantom and cylindrical target sizes between 2 and 25mm in diameter following a dosimetric end-to-end test concept. RESULTS The setup with the CRS provided a uniform dose distribution across the target. An agreement of better than5% between the planned dose and the measurements was obtained for a target with 3mm diameter (collimator 5mm). A 2mm difference between the collimator and the target diameter (target being 2 mm smaller than the collimator) sufficed to cover the whole target with the planned dose in the setup with CRS. Using the BRS setup (target 8mm, collimator 12mm) resulted in non-homogeneous dose distributions, with a dose discrepancy of up to 10% between the planned and measured doses. CONCLUSION The clinical proton infrastructure with adequate beam line adaptations and a state-of-the-art TPS based on MC dose calculations enables small animal irradiations with a high dosimetric precision and accuracy for target sizes down to 3mm.
Collapse
Affiliation(s)
- Monika Clausen
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Austria.
| | - Sirinya Ruangchan
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Austria; Division of Therapeutic Radiation and Oncology, Department of Radiology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Arame Sotoudegan
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Austria
| | - Andreas F Resch
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Austria
| | - Barbara Knäusl
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Austria
| | - Hugo Palmans
- Division of Medical Physics, MedAustron Ion Therapy Center, Wiener Neustadt, Austria; National Physical Laboratory, Teddington, United Kingdom
| | - Dietmar Georg
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Austria; Division of Medical Physics, MedAustron Ion Therapy Center, Wiener Neustadt, Austria
| |
Collapse
|
14
|
Winter SF, Vaios EJ, Shih HA, Grassberger C, Parsons MW, Gardner MM, Ehret F, Kaul D, Boehmerle W, Endres M, Dietrich J. Mitigating Radiotoxicity in the Central Nervous System: Role of Proton Therapy. Curr Treat Options Oncol 2023; 24:1524-1549. [PMID: 37728819 DOI: 10.1007/s11864-023-01131-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/08/2023] [Indexed: 09/21/2023]
Abstract
OPINION STATEMENT Central nervous system (CNS) radiotoxicity remains a challenge in neuro-oncology. Dose distribution advantages of protons over photons have prompted increased use of brain-directed proton therapy. While well-recognized among pediatric populations, the benefit of proton therapy among adults with CNS malignancies remains controversial. We herein discuss the role of protons in mitigating late CNS radiotoxicities in adult patients. Despite limited clinical trials, evidence suggests toxicity profile advantages of protons over conventional radiotherapy, including retention of neurocognitive function and brain volume. Modelling studies predict superior dose conformality of protons versus state-of-the-art photon techniques reduces late radiogenic vasculopathies, endocrinopathies, and malignancies. Conversely, potentially higher brain tissue necrosis rates following proton therapy highlight a need to resolve uncertainties surrounding the impact of variable biological effectiveness of protons on dose distribution. Clinical trials comparing best photon and particle-based therapy are underway to establish whether protons substantially improve long-term treatment-related outcomes in adults with CNS malignancies.
Collapse
Affiliation(s)
- Sebastian F Winter
- Department of Neurology and MGH Cancer Center, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
- Department of Neurology and Experimental Neurology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117, Berlin, Germany.
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Junior Clinician Scientist Program, 10117, Berlin, Germany.
| | - Eugene J Vaios
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Helen A Shih
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Clemens Grassberger
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Michael W Parsons
- Department of Psychiatry, Psychology Assessment Center, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Melissa M Gardner
- Department of Psychiatry, Psychology Assessment Center, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Felix Ehret
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Junior Clinician Scientist Program, 10117, Berlin, Germany
- Department of Radiation Oncology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353, Berlin, Germany
- Charité - Universitätsmedizin Berlin, Berlin, Germany; German Cancer Consortium (DKTK), partner site Berlin, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - David Kaul
- Department of Radiation Oncology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353, Berlin, Germany
- Charité - Universitätsmedizin Berlin, Berlin, Germany; German Cancer Consortium (DKTK), partner site Berlin, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Wolfgang Boehmerle
- Department of Neurology and Experimental Neurology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117, Berlin, Germany
| | - Matthias Endres
- Department of Neurology and Experimental Neurology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117, Berlin, Germany
- Center for Stroke Research Berlin, Berlin, Germany
- ExcellenceCluster NeuroCure, Berlin, Germany
- German Center for Neurodegenerative Diseases (DZNE), partner site Berlin, Berlin, Germany
- German Centre for Cardiovascular Research (DZHK), partner site Berlin, Berlin, Germany
| | - Jorg Dietrich
- Department of Neurology and MGH Cancer Center, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
15
|
Beddok A, Lim R, Thariat J, Shih HA, El Fakhri G. A Comprehensive Primer on Radiation Oncology for Non-Radiation Oncologists. Cancers (Basel) 2023; 15:4906. [PMID: 37894273 PMCID: PMC10605284 DOI: 10.3390/cancers15204906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/05/2023] [Accepted: 10/07/2023] [Indexed: 10/29/2023] Open
Abstract
Background: Multidisciplinary management is crucial in cancer diagnosis and treatment. Multidisciplinary teams include specialists in surgery, medical therapies, and radiation therapy (RT), each playing unique roles in oncology care. One significant aspect is RT, guided by radiation oncologists (ROs). This paper serves as a detailed primer for non-oncologists, medical students, or non-clinical investigators, educating them on contemporary RT practices. Methods: This report follows the process of RT planning and execution. Starting from the decision-making in multidisciplinary teams to the completion of RT and subsequent patient follow-up, it aims to offer non-oncologists an understanding of the RO's work in a comprehensive manner. Results: The first step in RT is a planning session that includes obtaining a CT scan of the area to be treated, known as the CT simulation. The patients are imaged in the exact position in which they will receive treatment. The second step, which is the primary source of uncertainty, involves the delineation of treatment targets and organs at risk (OAR). The objective is to ensure precise irradiation of the target volume while sparing the OARs as much as possible. Various radiation modalities, such as external beam therapy with electrons, photons, or particles (including protons and carbon ions), as well as brachytherapy, are utilized. Within these modalities, several techniques, such as three-dimensional conformal RT, intensity-modulated RT, volumetric modulated arc therapy, scattering beam proton therapy, and intensity-modulated proton therapy, are employed to achieve optimal treatment outcomes. The RT plan development is an iterative process involving medical physicists, dosimetrists, and ROs. The complexity and time required vary, ranging from an hour to a week. Once approved, RT begins, with image-guided RT being standard practice for patient alignment. The RO manages acute toxicities during treatment and prepares a summary upon completion. There is a considerable variance in practices, with some ROs offering lifelong follow-up and managing potential late effects of treatment. Conclusions: Comprehension of RT clinical effects by non-oncologists providers significantly elevates long-term patient care quality. Hence, educating non-oncologists enhances care for RT patients, underlining this report's importance.
Collapse
Affiliation(s)
- Arnaud Beddok
- Department of Radiation Oncology, Institut Godinot, 51100 Reims, France
- Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Ruth Lim
- Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Juliette Thariat
- Department of Radiation Oncology, Centre François-Baclesse, 14000 Caen, France
| | - Helen A. Shih
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Georges El Fakhri
- Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
16
|
Näsmark T, Andersson J. The influence of dual-energy computed tomography image noise in proton therapy treatment planning. Phys Imaging Radiat Oncol 2023; 28:100493. [PMID: 37789872 PMCID: PMC10544042 DOI: 10.1016/j.phro.2023.100493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 09/04/2023] [Accepted: 09/18/2023] [Indexed: 10/05/2023] Open
Abstract
Background and purpose In proton therapy, a 3.5% margin is often used to account for proton range uncertainties, of which computed tomography (CT) image noise is assumed to contribute 0.5%. This work evaluates the noise-sensitivity of three dual-energy computed tomography (DECT)-based methods for mapping proton stopping power relative to water (SPR): Näsmark & Andersson (N&A), Landry-Saito (L-S), and the commercial application DirectSPR. Methods and materials DECT image data of a CIRS-062M phantom was acquired with CT scanners from two different vendors. Acquisitions were repeated 30 times to account for intra- and inter-scan variations. SPR maps were generated with the three DECT-based methods and range simulated in a commercial treatment planning system. Results Noise in input data was amplified in L-S SPR maps, kept level with DirectSPR, while N&A compressed noise overall but displayed sensitivity to the choice of input data, potentially leading to increased noise levels. In our simulations, only N&A improved upon the assumed 0.5% noise contribution to range uncertainty on one scanner. On the other scanner, uncertainties exceeded 0.5% for all three methods. Mitigation of this issue was demonstrated by using a method employing virtual mono-energetic images as input. Increasing imaging radiation dose, as expected, alleviates the problem, while applying noise reduction only helped to a lesser extent. Conclusions While range uncertainty due to noise is small compared to other contributions, it becomes more important as we move towards smaller treatment margins and the noise-sensitivity of SPR mapping methods should be carefully estimated and considered before clinical implementation.
Collapse
Affiliation(s)
- Torbjörn Näsmark
- Department of Radiation Sciences, Radiation Physics, Umeå University, SE-901 85 UMEÅ, Sweden
| | - Jonas Andersson
- Department of Radiation Sciences, Radiation Physics, Umeå University, SE-901 85 UMEÅ, Sweden
| |
Collapse
|
17
|
Taasti VT, Decabooter E, Eekers D, Compter I, Rinaldi I, Bogowicz M, van der Maas T, Kneepkens E, Schiffelers J, Stultiens C, Hendrix N, Pijls M, Emmah R, Fonseca GP, Unipan M, van Elmpt W. Clinical benefit of range uncertainty reduction in proton treatment planning based on dual-energy CT for neuro-oncological patients. Br J Radiol 2023; 96:20230110. [PMID: 37493227 PMCID: PMC10461272 DOI: 10.1259/bjr.20230110] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2023] [Revised: 06/01/2023] [Accepted: 06/14/2023] [Indexed: 07/27/2023] Open
Abstract
OBJECTIVE Several studies have shown that dual-energy CT (DECT) can lead to improved accuracy for proton range estimation. This study investigated the clinical benefit of reduced range uncertainty, enabled by DECT, in robust optimisation for neuro-oncological patients. METHODS DECT scans for 27 neuro-oncological patients were included. Commercial software was applied to create stopping-power ratio (SPR) maps based on the DECT scan. Two plans were robustly optimised on the SPR map, keeping the beam and plan settings identical to the clinical plan. One plan was robustly optimised and evaluated with a range uncertainty of 3% (as used clinically; denoted 3%-plan); the second plan applied a range uncertainty of 2% (2%-plan). Both plans were clinical acceptable and optimal. The dose-volume histogram parameters were compared between the two plans. Two experienced neuro-radiation oncologists determined the relevant dose difference for each organ-at-risk (OAR). Moreover, the OAR toxicity levels were assessed. RESULTS For 24 patients, a dose reduction >0.5/1 Gy (relevant dose difference depending on the OAR) was seen in one or more OARs for the 2%-plan; e.g. for brainstem D0.03cc in 10 patients, and hippocampus D40% in 6 patients. Furthermore, 12 patients had a reduction in toxicity level for one or two OARs, showing a clear benefit for the patient. CONCLUSION Robust optimisation with reduced range uncertainty allows for reduction of OAR toxicity, providing a rationale for clinical implementation. Based on these results, we have clinically introduced DECT-based proton treatment planning for neuro-oncological patients, accompanied with a reduced range uncertainty of 2%. ADVANCES IN KNOWLEDGE This study shows the clinical benefit of range uncertainty reduction from 3% to 2% in robustly optimised proton plans. A dose reduction to one or more OARs was seen for 89% of the patients, and 44% of the patients had an expected toxicity level decrease.
Collapse
Affiliation(s)
- Vicki Trier Taasti
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Esther Decabooter
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Daniëlle Eekers
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Inge Compter
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Ilaria Rinaldi
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Marta Bogowicz
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Tim van der Maas
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Esther Kneepkens
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Jacqueline Schiffelers
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Cissy Stultiens
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Nicole Hendrix
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Mirthe Pijls
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Rik Emmah
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Gabriel Paiva Fonseca
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Mirko Unipan
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Wouter van Elmpt
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| |
Collapse
|
18
|
Kong X, Wang Y, Huang J, Zhang W, Du C, Yin Y, Xue H, Gao H, Liu K, Wu T, Sun L. Microdosimetric assessment about proton spread-out Bragg peak at different depths based on the normal human mesh-type cell population model. Phys Med Biol 2023; 68:175010. [PMID: 37578025 DOI: 10.1088/1361-6560/acec2b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 07/31/2023] [Indexed: 08/15/2023]
Abstract
Objective.In clinical proton therapy, the spread-out Bragg peak (SOBP) is commonly used to fit the target shape. Dose depositions at microscopic sites vary, even with a consistent absorbed dose (D) in SOBP. In the present study, monolayer mesh-type cell population models were developed for microdosimetric assessment at different SOBP depths.Approach.Normal human bronchial epithelial (BEAS-2B) and hepatocytes (L-O2) mesh-type cell models were constructed based on fluorescence tomography images of normal human cells. Particle transport simulation in cell populations was performed coupled with Monte Carlo software PHITS. The relationship between microdosimetry and macrodosimetry of SOBP at different depths was described by analyzing the microdosimetric indicators such as specific energyz,specific energy distributionfz,D,and relative standard deviationσz/z¯within cells. Additionally, the microdosimetric distributions characteristics and their contributing factors were also discussed.Main results.The microscopic dose distribution is strongly influenced by cellular size, shape, and material. The mean specific energyz¯of nucleus and cytoplasm in the cell population is greater than the overall absorbed dose of the cell population model (Dp), with a maximumz¯/Dpof 1.1. The cellular dose distribution is different between the BEAS-2B mesh-type model and its concentric ellipsoid geometry-type model, which difference inz¯is about 10.3% for the nucleus and about 7.5% for the cytoplasm with the SOBP depth of 15 cm. WhenD= 2 Gy, the maximumzof L-O2 nucleus reaches 2.8 Gy andσz/z¯is 5.1% at the mid-depth SOBP (16-18 cm); while the maximumzof the BEAS-2B nucleus reaches 2.2 Gy with only 2.7% ofσz/z¯.Significance.The significant variation of microdosimetric distributions of SOBP different depths indicates the necessity to use mesh-type cell population models, which have the potential to be compared with biological results and build the bio-physical model.
Collapse
Affiliation(s)
- Xianghui Kong
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Yidi Wang
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Jiachen Huang
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Wenyue Zhang
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Chuansheng Du
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Yuchen Yin
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Huiyuan Xue
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Han Gao
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Kun Liu
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Tao Wu
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| | - Liang Sun
- State Key Laboratory of Radiation Medicine and Protection, Suzhou 215123, People's Republic of China
- School of Radiation Medicine and Protection, Soochow University, Suzhou 215123, People's Republic of China
- Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, People's Republic of China
| |
Collapse
|
19
|
Balakin VE, Rozanova OM, Smirnova EN, Belyakova TA, Strelnikova NS, Smirnov AV, Shemyakov AE. Growth Induction of Solid Ehrlich Ascitic Carcinoma in Mice after Proton Irradiation of Tumor Cells Ex Vivo. DOKL BIOCHEM BIOPHYS 2023; 511:151-155. [PMID: 37833598 DOI: 10.1134/s1607672923700229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/21/2023] [Accepted: 03/21/2023] [Indexed: 10/15/2023]
Abstract
This study presents data on the growth rate and frequency of induction of the solid form of Ehrlich's ascites carcinoma (EAC) in mice in the short and long term after inoculation of ascitic cells irradiated ex vivo with a proton beam in the dose range of 30-150 Gy. It was shown that the growth rate of solid tumors after inoculation of irradiated cells ex vivo coincided with the growth of tumors in the control group. The frequency of tumor induction in mice after inoculation of EAC cells irradiated at a dose of 30 Gy was 80%, 60 Gy-60%, 90 Gy-25%, and 120 Gy-10%; at irradiation at a dose of 150 Gy, no tumors appeared during the entire observation period. Thus, we determined the dose of proton radiation required to eliminate tumor cells and/or signaling factors that can lead to the induction of tumor growth of EAC in mice.
Collapse
Affiliation(s)
- V E Balakin
- Physical-Technical Center, Branch of Lebedev Physical Institute, Russian Academy of Sciences, Protvino, Russia
| | - O M Rozanova
- Institute of Theoretical and Experimental Biophysics, Russian Academy of Sciences, Pushchino, Russia
| | - E N Smirnova
- Institute of Theoretical and Experimental Biophysics, Russian Academy of Sciences, Pushchino, Russia
| | - T A Belyakova
- Physical-Technical Center, Branch of Lebedev Physical Institute, Russian Academy of Sciences, Protvino, Russia
| | - N S Strelnikova
- Physical-Technical Center, Branch of Lebedev Physical Institute, Russian Academy of Sciences, Protvino, Russia.
| | - A V Smirnov
- Physical-Technical Center, Branch of Lebedev Physical Institute, Russian Academy of Sciences, Protvino, Russia
| | - A E Shemyakov
- Physical-Technical Center, Branch of Lebedev Physical Institute, Russian Academy of Sciences, Protvino, Russia
| |
Collapse
|
20
|
Bertolet A, Chamseddine I, Paganetti H, Schuemann J. The complexity of DNA damage by radiation follows a Gamma distribution: insights from the Microdosimetric Gamma Model. Front Oncol 2023; 13:1196502. [PMID: 37397382 PMCID: PMC10313124 DOI: 10.3389/fonc.2023.1196502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 05/30/2023] [Indexed: 07/04/2023] Open
Abstract
Introduction DNA damage is the main predictor of response to radiation therapy for cancer. Its Q8 quantification and characterization are paramount for treatment optimization, particularly in advanced modalities such as proton and alpha-targeted therapy. Methods We present a novel approach called the Microdosimetric Gamma Model (MGM) to address this important issue. The MGM uses the theory of microdosimetry, specifically the mean energy imparted to small sites, as a predictor of DNA damage properties. MGM provides the number of DNA damage sites and their complexity, which were determined using Monte Carlo simulations with the TOPAS-nBio toolkit for monoenergetic protons and alpha particles. Complexity was used together with a illustrative and simplistic repair model to depict the differences between high and low LET radiations. Results DNA damage complexity distributions were were found to follow a Gamma distribution for all monoenergetic particles studied. The MGM functions allowed to predict number of DNA damage sites and their complexity for particles not simulated with microdosimetric measurements (yF) in the range of those studied. Discussion Compared to current methods, MGM allows for the characterization of DNA damage induced by beams composed of multi-energy components distributed over any time configuration and spatial distribution. The output can be plugged into ad hoc repair models that can predict cell killing, protein recruitment at repair sites, chromosome aberrations, and other biological effects, as opposed to current models solely focusing on cell survival. These features are particularly important in targeted alpha-therapy, for which biological effects remain largely uncertain. The MGM provides a flexible framework to study the energy, time, and spatial aspects of ionizing radiation and offers an excellent tool for studying and optimizing the biological effects of these radiotherapy modalities.
Collapse
Affiliation(s)
- Alejandro Bertolet
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, United States
| | | | | | | |
Collapse
|
21
|
Giovannini D, De Angelis C, Astorino MD, Fratini E, Cisbani E, Bazzano G, Ampollini A, Piccinini M, Nichelatti E, Trinca E, Nenzi P, Mancuso M, Picardi L, Marino C, Ronsivalle C, Pazzaglia S. In Vivo Radiobiological Investigations with the TOP-IMPLART Proton Beam on a Medulloblastoma Mouse Model. Int J Mol Sci 2023; 24:ijms24098281. [PMID: 37175984 PMCID: PMC10179102 DOI: 10.3390/ijms24098281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 05/02/2023] [Accepted: 05/03/2023] [Indexed: 05/15/2023] Open
Abstract
Protons are now increasingly used to treat pediatric medulloblastoma (MB) patients. We designed and characterized a setup to deliver proton beams for in vivo radiobiology experiments at a TOP-IMPLART facility, a prototype of a proton-therapy linear accelerator developed at the ENEA Frascati Research Center, with the goal of assessing the feasibility of TOP-IMPLART for small animal proton therapy research. Mice bearing Sonic-Hedgehog (Shh)-dependent MB in the flank were irradiated with protons to test whether irradiation could be restricted to a specific depth in the tumor tissue and to compare apoptosis induced by the same dose of protons or photons. In addition, the brains of neonatal mice at postnatal day 5 (P5), representing a very small target, were irradiated with 6 Gy of protons with two different collimated Spread-Out Bragg Peaks (SOBPs). Apoptosis was visualized by immunohistochemistry for the apoptotic marker caspase-3-activated, and quantified by Western blot. Our findings proved that protons could be delivered to the upper part while sparing the deepest part of MB. In addition, a comparison of the effectiveness of protons and photons revealed a very similar increase in the expression of cleaved caspase-3. Finally, by using a very small target, the brain of P5-neonatal mice, we demonstrated that the proton irradiation field reached the desired depth in brain tissue. Using the TOP-IMPLART accelerator we established setup and procedures for proton irradiation, suitable for translational preclinical studies. This is the first example of in vivo experiments performed with a "full-linac" proton-therapy accelerator.
Collapse
Affiliation(s)
- Daniela Giovannini
- ENEA SSPT-TECS-TEB, Casaccia Research Center, Division of Health Protection Technology (TECS), Agenzia Nazionale per le Nuove Tecnologie, l'Energia e lo Sviluppo Economico Sostenibile (ENEA), Via Anguillarese 301, 00123 Rome, Italy
| | - Cinzia De Angelis
- Istituto Superiore di Sanità (ISS), Viale Regina Elena 299, 00161 Rome, Italy
| | - Maria Denise Astorino
- ENEA FSN-TECFIS-APAM, Frascati Research Center, Via Enrico Fermi 45, 00044 Frascati, Italy
| | - Emiliano Fratini
- ENEA SSPT-TECS-TEB, Casaccia Research Center, Division of Health Protection Technology (TECS), Agenzia Nazionale per le Nuove Tecnologie, l'Energia e lo Sviluppo Economico Sostenibile (ENEA), Via Anguillarese 301, 00123 Rome, Italy
| | - Evaristo Cisbani
- Istituto Superiore di Sanità (ISS), Viale Regina Elena 299, 00161 Rome, Italy
| | - Giulia Bazzano
- ENEA FSN-TECFIS-APAM, Frascati Research Center, Via Enrico Fermi 45, 00044 Frascati, Italy
| | - Alessandro Ampollini
- ENEA FSN-TECFIS-APAM, Frascati Research Center, Via Enrico Fermi 45, 00044 Frascati, Italy
| | - Massimo Piccinini
- ENEA FSN-TECFIS-MNF, Frascati Research Center, Via Enrico Fermi 45, 00044 Frascati, Italy
| | - Enrico Nichelatti
- ENEA FSN-TECFIS-MNF, Casaccia Research Center, Via Anguillarese 301, 00123 Rome, Italy
| | - Emiliano Trinca
- ENEA FSN-TECFIS-APAM, Frascati Research Center, Via Enrico Fermi 45, 00044 Frascati, Italy
| | - Paolo Nenzi
- ENEA FSN-TECFIS-APAM, Frascati Research Center, Via Enrico Fermi 45, 00044 Frascati, Italy
| | - Mariateresa Mancuso
- ENEA SSPT-TECS-TEB, Casaccia Research Center, Division of Health Protection Technology (TECS), Agenzia Nazionale per le Nuove Tecnologie, l'Energia e lo Sviluppo Economico Sostenibile (ENEA), Via Anguillarese 301, 00123 Rome, Italy
| | - Luigi Picardi
- ENEA FSN-TECFIS-APAM, Frascati Research Center, Via Enrico Fermi 45, 00044 Frascati, Italy
| | - Carmela Marino
- ENEA SSPT-TECS-TEB, Casaccia Research Center, Division of Health Protection Technology (TECS), Agenzia Nazionale per le Nuove Tecnologie, l'Energia e lo Sviluppo Economico Sostenibile (ENEA), Via Anguillarese 301, 00123 Rome, Italy
| | - Concetta Ronsivalle
- ENEA FSN-TECFIS-APAM, Frascati Research Center, Via Enrico Fermi 45, 00044 Frascati, Italy
| | - Simonetta Pazzaglia
- ENEA SSPT-TECS-TEB, Casaccia Research Center, Division of Health Protection Technology (TECS), Agenzia Nazionale per le Nuove Tecnologie, l'Energia e lo Sviluppo Economico Sostenibile (ENEA), Via Anguillarese 301, 00123 Rome, Italy
| |
Collapse
|
22
|
Gaito S, Marvaso G, Ortiz R, Crellin A, Aznar MC, Indelicato DJ, Pan S, Whitfield G, Alongi F, Jereczek-Fossa BA, Burnet N, Li MP, Rothwell B, Smith E, Colaco RJ. Proton Beam Therapy in the Oligometastatic/Oligorecurrent Setting: Is There a Role? A Literature Review. Cancers (Basel) 2023; 15:cancers15092489. [PMID: 37173955 PMCID: PMC10177340 DOI: 10.3390/cancers15092489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/21/2023] [Accepted: 04/25/2023] [Indexed: 05/15/2023] Open
Abstract
BACKGROUND Stereotactic ablative radiotherapy (SABR) and stereotactic radiosurgery (SRS) with conventional photon radiotherapy (XRT) are well-established treatment options for selected patients with oligometastatic/oligorecurrent disease. The use of PBT for SABR-SRS is attractive given the property of a lack of exit dose. The aim of this review is to evaluate the role and current utilisation of PBT in the oligometastatic/oligorecurrent setting. METHODS Using Medline and Embase, a comprehensive literature review was conducted following the PICO (Patients, Intervention, Comparison, and Outcomes) criteria, which returned 83 records. After screening, 16 records were deemed to be relevant and included in the review. RESULTS Six of the sixteen records analysed originated in Japan, six in the USA, and four in Europe. The focus was oligometastatic disease in 12, oligorecurrence in 3, and both in 1. Most of the studies analysed (12/16) were retrospective cohorts or case reports, two were phase II clinical trials, one was a literature review, and one study discussed the pros and cons of PBT in these settings. The studies presented in this review included a total of 925 patients. The metastatic sites analysed in these articles were the liver (4/16), lungs (3/16), thoracic lymph nodes (2/16), bone (2/16), brain (1/16), pelvis (1/16), and various sites in 2/16. CONCLUSIONS PBT could represent an option for the treatment of oligometastatic/oligorecurrent disease in patients with a low metastatic burden. Nevertheless, due to its limited availability, PBT has traditionally been funded for selected tumour indications that are defined as curable. The availability of new systemic therapies has widened this definition. This, together with the exponential growth of PBT capacity worldwide, will potentially redefine its commissioning to include selected patients with oligometastatic/oligorecurrent disease. To date, PBT has been used with encouraging results for the treatment of liver metastases. However, PBT could be an option in those cases in which the reduced radiation exposure to normal tissues leads to a clinically significant reduction in treatment-related toxicities.
Collapse
Affiliation(s)
- Simona Gaito
- Proton Clinical Outcomes Unit, The Christie NHS Proton Beam Therapy Centre, Manchester M20 4BX, UK
- Division of Clinical Cancer Science, School of Medical Sciences, The University of Manchester, Manchester M13 9PL, UK
| | - Giulia Marvaso
- Department of Oncology and Hemato-Oncology, University of Milan, 20122 Milan, Italy
- Department of Radiation Oncology, IEO European Institute of Oncology IRCCS, 20126 Milan, Italy
| | - Ramon Ortiz
- Department of Radiation Oncology, University of California, San Francisco, CA 94720, USA
| | - Adrian Crellin
- National Lead Proton Beam Therapy NHSe, Manchester M20 4BX, UK
| | - Marianne C Aznar
- Division of Clinical Cancer Science, School of Medical Sciences, The University of Manchester, Manchester M13 9PL, UK
| | - Daniel J Indelicato
- Department of Radiation Oncology, University of Florida, Jacksonville, FL 32206, USA
| | - Shermaine Pan
- Department of Proton Beam Therapy, The Christie Proton Beam Therapy Centre, Manchester M20 3DA, UK
| | - Gillian Whitfield
- Division of Clinical Cancer Science, School of Medical Sciences, The University of Manchester, Manchester M13 9PL, UK
- Department of Proton Beam Therapy, The Christie Proton Beam Therapy Centre, Manchester M20 3DA, UK
| | - Filippo Alongi
- Advanced Radiation Oncology Department, IRCCS Ospedale Sacro Cuore don Calabria, 37024 Verona, Italy
- Division of Radiology and Radiotherapy, University of Brescia, 25121 Brescia, Italy
| | - Barbara Alicja Jereczek-Fossa
- Department of Oncology and Hemato-Oncology, University of Milan, 20122 Milan, Italy
- Department of Radiation Oncology, IEO European Institute of Oncology IRCCS, 20126 Milan, Italy
| | - Neil Burnet
- Department of Proton Beam Therapy, The Christie Proton Beam Therapy Centre, Manchester M20 3DA, UK
| | - Michelle P Li
- Department of Proton Beam Therapy, The Christie Proton Beam Therapy Centre, Manchester M20 3DA, UK
- Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, VIC 3000, Australia
- Sir Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne, VIC 3010, Australia
| | - Bethany Rothwell
- Division of Physics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA
| | - Ed Smith
- Proton Clinical Outcomes Unit, The Christie NHS Proton Beam Therapy Centre, Manchester M20 4BX, UK
- Division of Clinical Cancer Science, School of Medical Sciences, The University of Manchester, Manchester M13 9PL, UK
- Department of Proton Beam Therapy, The Christie Proton Beam Therapy Centre, Manchester M20 3DA, UK
| | - Rovel J Colaco
- Department of Proton Beam Therapy, The Christie Proton Beam Therapy Centre, Manchester M20 3DA, UK
| |
Collapse
|
23
|
Peters N, Trier Taasti V, Ackermann B, Bolsi A, Vallhagen Dahlgren C, Ellerbrock M, Fracchiolla F, Gomà C, Góra J, Cambraia Lopes P, Rinaldi I, Salvo K, Sojat Tarp I, Vai A, Bortfeld T, Lomax A, Richter C, Wohlfahrt P. Consensus guide on CT-based prediction of stopping-power ratio using a Hounsfield look-up table for proton therapy. Radiother Oncol 2023; 184:109675. [PMID: 37084884 DOI: 10.1016/j.radonc.2023.109675] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 03/08/2023] [Accepted: 04/10/2023] [Indexed: 04/23/2023]
Abstract
BACKGROUND AND PURPOSE Studies have shown large variations in stopping-power ratio (SPR) prediction from computed tomography (CT) across European proton centres. To standardise this process, a step-by-step guide on specifying a Hounsfield look-up table (HLUT) is presented here. MATERIALS AND METHODS The HLUT specification process is divided into six steps: Phantom setup, CT acquisition, CT number extraction, SPR determination, HLUT specification, and HLUT validation. Appropriate CT phantoms have a head- and body-sized part, with tissue-equivalent inserts in regard to X-ray and proton interactions. CT numbers are extracted from a region-of-interest covering the inner 70% of each insert in-plane and several axial CT slices in scan direction. For optimal HLUT specification, the SPR of phantom inserts is measured in a proton beam and the SPR of tabulated human tissues is computed stoichiometrically at 100 MeV. Including both phantom inserts and tabulated human tissues increases HLUT stability. Piecewise linear regressions are performed between CT numbers and SPRs for four tissue groups (lung, adipose, soft tissue, and bone) and then connected with straight lines. Finally, a thorough but simple validation is performed. RESULTS The best practices and individual challenges are explained comprehensively for each step. A well-defined strategy for specifying the connection points between the individual line segments of the HLUT is presented. The guide was tested exemplarily on three CT scanners from different vendors, proving its feasibility. CONCLUSION The presented step-by-step guide for CT-based HLUT specification with recommendations and examples can contribute to reduce inter-centre variations in SPR prediction.
Collapse
Affiliation(s)
- Nils Peters
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Germany; Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA, USA.
| | - Vicki Trier Taasti
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands.
| | - Benjamin Ackermann
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Alessandra Bolsi
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| | | | - Malte Ellerbrock
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Francesco Fracchiolla
- Azienda Provinciale per i Servizi Sanitari (APSS) Protontherapy Department, Trento, Italy
| | - Carles Gomà
- Department of Radiation Oncology, Hospital Clínic de Barcelona, Barcelona, Spain
| | - Joanna Góra
- MedAustron Ion Therapy Center, Wiener Neustadt, Austria
| | | | - Ilaria Rinaldi
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Koen Salvo
- AZ Sint-Maarten, Department of Radiotherapy, Mechelen, Belgium
| | - Ivanka Sojat Tarp
- Aarhus University Hospital, Danish Center for Particle Therapy, Aarhus, Denmark
| | - Alessandro Vai
- Radiotherapy Department, Center for National Oncological Hadrontherapy (CNAO), 27100 Pavia, Italy
| | - Thomas Bortfeld
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA, USA
| | - Antony Lomax
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; German Cancer Consortium (DKTK), partner site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Patrick Wohlfahrt
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA, USA
| |
Collapse
|
24
|
Vestergaard CD, Muren LP, Elstrøm UV, Johansen JG, Taasti VT. Tissue-specific range uncertainty estimation in proton therapy. Phys Imaging Radiat Oncol 2023; 26:100441. [PMID: 37182194 PMCID: PMC10173296 DOI: 10.1016/j.phro.2023.100441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 04/12/2023] [Accepted: 04/18/2023] [Indexed: 05/16/2023] Open
Abstract
Background and Purpose Proton therapy is sensitive to range uncertainties, which typically are accounted for by margins or robust optimization, based on tissue-independent uncertainties. However, range uncertainties have been shown to depend on the specific tissues traversed. The aim of this study was to investigate the differences between range margins based on stopping power ratio (SPR) uncertainties which were tissue-specific (applied voxel-wise) or fixed (tissue-independent or composite). Materials and Methods Uncertainties originating from imaging, computed tomography (CT) number estimation, and SPR estimation were calculated for low-, medium-, and high-density tissues to quantify the tissue-specific SPR uncertainties. Four clinical treatment plans (four different tumor sites) were created and recomputed after applying either tissue-specific or fixed SPR uncertainties. Plans with tissue-specific and fixed uncertainties were compared, based on dose-volume-histogram parameters for both targets and organs-at-risk. Results The total SPR uncertainties were 7.0% for low-, 1.0% for medium-, and 1.3% for high-density tissues. Differences between the proton plans with tissue-specific and fixed uncertainties were mainly found in the vicinity of the target. Composite uncertainties were found to capture the tissue-specific uncertainties more accurately than the tissue-independent uncertainties. Conclusion Different SPR uncertainties were found for low-, medium-, and high-density tissues indicating that range margins based on tissue-specific uncertainties may be more exact than the standard approach of using tissue-independent uncertainties. Differences between applying tissue-specific and fixed uncertainties were found, however, a fixed uncertainty might still be sufficient, but with a magnitude that depends on the body region.
Collapse
Affiliation(s)
- Casper Dueholm Vestergaard
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Corresponding author at: Danish Centre for Particle Therapy, Palle Juul Jensens Boulevard 25, 8200 Aarhus N, Denmark.
| | - Ludvig Paul Muren
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | | | | | - Vicki Trier Taasti
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Department of Radiation Oncology (MAASTRO), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| |
Collapse
|
25
|
Trnkova P, Zhang Y, Toshito T, Heijmen B, Richter C, Aznar MC, Albertini F, Bolsi A, Daartz J, Knopf AC, Bertholet J. A survey of practice patterns for adaptive particle therapy for interfractional changes. Phys Imaging Radiat Oncol 2023; 26:100442. [PMID: 37197154 PMCID: PMC10183663 DOI: 10.1016/j.phro.2023.100442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 04/22/2023] [Accepted: 04/24/2023] [Indexed: 05/19/2023] Open
Abstract
Background and purpose Anatomical changes may compromise the planned target coverage and organs-at-risk dose in particle therapy. This study reports on the practice patterns for adaptive particle therapy (APT) to evaluate current clinical practice and wishes and barriers to further implementation. Materials and methods An institutional questionnaire was distributed to PT centres worldwide (7/2020-6/2021) asking which type of APT was used, details of the workflow, and what the wishes and barriers to implementation were. Seventy centres from 17 countries participated. A three-round Delphi consensus analysis (10/2022) among the authors followed to define recommendations on required actions and future vision. Results Out of the 68 clinically operational centres, 84% were users of APT for at least one treatment site with head and neck being most common. APT was mostly performed offline with only two online APT users (plan-library). No centre used online daily re-planning. Daily 3D imaging was used for APT by 19% of users. Sixty-eight percent of users had plans to increase their use or change their technique for APT. The main barrier was "lack of integrated and efficient workflows". Automation and speed, reliable dose deformation for dose accumulation and higher quality of in-room volumetric imaging were identified as the most urgent task for clinical implementation of online daily APT. Conclusion Offline APT was implemented by the majority of PT centres. Joint efforts between industry research and clinics are needed to translate innovations into efficient and clinically feasible workflows for broad-scale implementation of online APT.
Collapse
Affiliation(s)
- Petra Trnkova
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
- Corresponding author.
| | - Ye Zhang
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| | - Toshiyuki Toshito
- Nagoya Proton Therapy Center, Nagoya City University West Medical Center, Nagoya, Japan
| | - Ben Heijmen
- Department of Radiotherapy, Erasmus University Medical Center (Erasmus MC), Rotterdam, the Netherlands
| | - Christian Richter
- OncoRay – National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden – Rossendorf, Dresden, Germany
| | - Marianne C. Aznar
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, United Kingdom
| | | | - Alessandra Bolsi
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| | - Juliane Daartz
- Department of Radiation Oncology, Massachusetts General Hospital & Harvard Medical School, Boston, MA 02114, United States of America
| | - Antje C. Knopf
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
- Institute for Medical Engineering and Medical Informatics, School of Life Science FHNW, Muttenz, Switzerland
| | - Jenny Bertholet
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, Bern, Switzerland
| |
Collapse
|
26
|
Missaglia A, Bourkadi-Idrissi A, Casamichiela F, Mazzucconi D, Carminati M, Agosteo S, Fiorini C. Prompt-gamma fall-off estimation with C-ion irradiation at clinical energies, using a knife-edge slit camera: A Monte Carlo study. Phys Med 2023; 107:102554. [PMID: 36907030 DOI: 10.1016/j.ejmp.2023.102554] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Revised: 02/09/2023] [Accepted: 02/18/2023] [Indexed: 03/12/2023] Open
Abstract
PURPOSE In-vivo range verification has been a hot topic in particle therapy since two decades. Many efforts have been done for proton therapy, while fewer studies were conducted considering a beam of carbon ions. In the present work, a simulation study was performed to show whether it is possible to measure the prompt-gamma fall-off inside the high neutron background typical of carbon-ion irradiation, using a knife-edge slit camera. In addition to this, we wanted to estimate the uncertainty in retrieving the particle range in the case of a pencil beam of C-ions at clinically relevant energy of 150 MeVu. METHODS For these purposes, the Monte Carlo code FLUKA was adopted for simulations and three different analytical methods were implemented to get the accuracy in the range retrieval of the simulated set-up. RESULTS The analysis of simulation data has brought to the promising and desired precision of about 4 mm in the determination of the dose profile fall-off in case of a spill irradiation, for which all the three cited methods were coherent in their predictions. CONCLUSIONS The Prompt Gamma Imaging technique should be further studied as a tool to reduce range uncertainties affecting carbon ion radiation therapy.
Collapse
Affiliation(s)
- Andrea Missaglia
- Dipartimento di Elettronica, Informazione e Bioingegneria - Politecnico di Milano, Via Ponzio, 34/5, 20133, Milan, Italy.
| | - Aicha Bourkadi-Idrissi
- Dipartimento di Elettronica, Informazione e Bioingegneria - Politecnico di Milano, Via Ponzio, 34/5, 20133, Milan, Italy; INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy.
| | - Francesco Casamichiela
- Dipartimento di Energia - Politecnico di Milano, Via Lambruschini, 4, 20156, Milan, Italy.
| | - Davide Mazzucconi
- INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy; Dipartimento di Energia - Politecnico di Milano, Via Lambruschini, 4, 20156, Milan, Italy.
| | - Marco Carminati
- Dipartimento di Elettronica, Informazione e Bioingegneria - Politecnico di Milano, Via Ponzio, 34/5, 20133, Milan, Italy; INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy.
| | - Stefano Agosteo
- INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy; Dipartimento di Energia - Politecnico di Milano, Via Lambruschini, 4, 20156, Milan, Italy.
| | - Carlo Fiorini
- Dipartimento di Elettronica, Informazione e Bioingegneria - Politecnico di Milano, Via Ponzio, 34/5, 20133, Milan, Italy; INFN - sezione di Milano, Via Giovanni Celoria, 16, 20133, Milan, Italy.
| |
Collapse
|
27
|
Yang M, Wohlfahrt P, Shen C, Bouchard H. Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential. Phys Med Biol 2023; 68. [PMID: 36595276 DOI: 10.1088/1361-6560/acabfa] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022]
Abstract
Range uncertainty has been a key factor preventing particle radiotherapy from reaching its full physical potential. One of the main contributing sources is the uncertainty in estimating particle stopping power (ρs) within patients. Currently, theρsdistribution in a patient is derived from a single-energy CT (SECT) scan acquired for treatment planning by converting CT number expressed in Hounsfield units (HU) of each voxel toρsusing a Hounsfield look-up table (HLUT), also known as the CT calibration curve. HU andρsshare a linear relationship with electron density but differ in their additional dependence on elemental composition through different physical properties, i.e. effective atomic number and mean excitation energy, respectively. Because of that, the HLUT approach is particularly sensitive to differences in elemental composition between real human tissues and tissue surrogates as well as tissue variations within and among individual patients. The use of dual-energy CT (DECT) forρsprediction has been shown to be effective in reducing the uncertainty inρsestimation compared to SECT. The acquisition of CT data over different x-ray spectra yields additional information on the material elemental composition. Recently, multi-energy CT (MECT) has been explored to deduct material-specific information with higher dimensionality, which has the potential to further improve the accuracy ofρsestimation. Even though various DECT and MECT methods have been proposed and evaluated over the years, these approaches are still only scarcely implemented in routine clinical practice. In this topical review, we aim at accelerating this translation process by providing: (1) a comprehensive review of the existing DECT/MECT methods forρsestimation with their respective strengths and weaknesses; (2) a general review of uncertainties associated with DECT/MECT methods; (3) a general review of different aspects related to clinical implementation of DECT/MECT methods; (4) other potential advanced DECT/MECT applications beyondρsestimation.
Collapse
Affiliation(s)
- Ming Yang
- The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, 1515 Holcombe Blvd Houston, TX 77030, United States of America
| | - Patrick Wohlfahrt
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA 02115, United States of America
| | - Chenyang Shen
- University of Texas Southwestern Medical Center, Department of Radiation Oncology, 2280 Inwood Rd Dallas, TX 75235, United States of America
| | - Hugo Bouchard
- Département de physique, Université de Montréal, Complexe des sciences, 1375 Avenue Thérèse-Lavoie-Roux, Montréal, Québec H2V0B3, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal, 900 Rue Saint-Denis, Montréal, Québec, H2X 0A9, Canada.,Département de radio-oncologie, Centre hospitalier de l'Université de Montréal, 1051 Rue Sanguinet, Montréal, Québec H2X 3E4, Canada
| |
Collapse
|
28
|
Calvo FA, Ayestaran A, Serrano J, Cambeiro M, Palma J, Meiriño R, Morcillo MA, Lapuente F, Chiva L, Aguilar B, Azcona D, Pedrero D, Pascau J, Delgado JM, Aristu J, Prezado Y. Practice-oriented solutions integrating intraoperative electron irradiation and personalized proton therapy for recurrent or unresectable cancers: Proof of concept and potential for dual FLASH effect. Front Oncol 2022; 12:1037262. [PMID: 36452493 PMCID: PMC9703091 DOI: 10.3389/fonc.2022.1037262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 10/26/2022] [Indexed: 11/15/2022] Open
Abstract
Background Oligo-recurrent disease has a consolidated evidence of long-term surviving patients due to the use of intense local cancer therapy. The latter combines real-time surgical exploration/resection with high-energy electron beam single dose of irradiation. This results in a very precise radiation dose deposit, which is an essential element of contemporary multidisciplinary individualized oncology. Methods Patient candidates to proton therapy were evaluated in Multidisciplinary Tumor Board to consider improved treatment options based on the institutional resources and expertise. Proton therapy was delivered by a synchrotron-based pencil beam scanning technology with energy levels from 70.2 to 228.7 MeV, whereas intraoperative electrons were generated in a miniaturized linear accelerator with dose rates ranging from 22 to 36 Gy/min (at Dmax) and energies from 6 to 12 MeV. Results In a period of 24 months, 327 patients were treated with proton therapy: 218 were adults, 97 had recurrent cancer, and 54 required re-irradiation. The specific radiation modalities selected in five cases included an integral strategy to optimize the local disease management by the combination of surgery, intraoperative electron boost, and external pencil beam proton therapy as components of the radiotherapy management. Recurrent cancer was present in four cases (cervix, sarcoma, melanoma, and rectum), and one patient had a primary unresectable locally advanced pancreatic adenocarcinoma. In re-irradiated patients (cervix and rectum), a tentative radical total dose was achieved by integrating beams of electrons (ranging from 10- to 20-Gy single dose) and protons (30 to 54-Gy Relative Biological Effectiveness (RBE), in 10-25 fractions). Conclusions Individual case solution strategies combining intraoperative electron radiation therapy and proton therapy for patients with oligo-recurrent or unresectable localized cancer are feasible. The potential of this combination can be clinically explored with electron and proton FLASH beams.
Collapse
Affiliation(s)
- Felipe A Calvo
- Department of Radiation Oncology, Clinica Universidad de Navarra, Madrid, Spain
| | - Adriana Ayestaran
- Department of Radiation Oncology, Clinica Universidad de Navarra, Madrid, Spain
| | - Javier Serrano
- Department of Radiation Oncology, Clinica Universidad de Navarra, Madrid, Spain
| | - Mauricio Cambeiro
- Department of Radiation Oncology, Clinica Universidad de Navarra, Madrid, Spain
| | - Jacobo Palma
- Department of Radiation Oncology, Clinica Universidad de Navarra, Madrid, Spain
| | - Rosa Meiriño
- Department of Radiation Oncology, Clinica Universidad de Navarra, Madrid, Spain
| | - Miguel A Morcillo
- Medical Applications Unit, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid, Spain
| | - Fernando Lapuente
- Department of Surgery, Clinica Universidad de Navarra, Madrid, Spain
| | - Luis Chiva
- Department of Gynecology and Obstretics, Clinica Universidad de Navarra, Madrid, Spain
| | - Borja Aguilar
- Department of Medical Physics, Clinica Universidad de Navarra, Madrid, Spain
| | - Diego Azcona
- Department of Medical Physics, Clinica Universidad de Navarra, Madrid, Spain
| | - Diego Pedrero
- Department of Medical Physics, Clinica Universidad de Navarra, Madrid, Spain
| | - Javier Pascau
- Department of Bioengineering and Aerospace Engineering, Universidad Carlos III de Madrid, Madrid, Spain
| | - José Miguel Delgado
- Department of Radiation Oncology, Clinica Universidad de Navarra, Madrid, Spain
| | - Javier Aristu
- Department of Radiation Oncology, Clinica Universidad de Navarra, Madrid, Spain
| | - Yolanda Prezado
- Translational Research Department. Institut Curie, Université PSL, CNRS UMR, Inserm, Signalisation, Radiobiologie et Cancer, Orsay, France.,Université Paris-Saclay, CNRS UMR, Inserm, Signalisation, Radiobiologie et Cancer, Orsay, France
| |
Collapse
|
29
|
Pirlepesov F, Wilson L, Moskvin VP, Breuer A, Parkins F, Lucas JT, Merchant TE, Faught AM. Three-dimensional dose and LET D prediction in proton therapy using artificial neural networks. Med Phys 2022; 49:7417-7427. [PMID: 36227617 PMCID: PMC9872814 DOI: 10.1002/mp.16043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 08/30/2022] [Accepted: 09/21/2022] [Indexed: 01/26/2023] Open
Abstract
PURPOSE Challenges in proton therapy include identifying patients most likely to benefit; ensuring consistent, high-quality plans as its adoption becomes more widespread; and recognizing biological uncertainties that may be related to increased relative biologic effectiveness driven by linear energy transfer (LET). Knowledge-based planning (KBP) is a domain that may help to address all three. METHODS Artificial neural networks were trained using 117 unique treatment plans and associated dose and dose-weighted LET (LETD ) distributions. The data set was split into training (n = 82), validation (n = 17), and test (n = 18) sets. Model performance was evaluated on the test set using dose- and LETD -volume metrics in the clinical target volume (CTV) and nearby organs at risk and Dice similarity coefficients (DSC) comparing predicted and planned isodose lines at 50%, 75%, and 95% of the prescription dose. RESULTS Dose-volume metrics significantly differed (α = 0.05) between predicted and planned dose distributions in only one dose-volume metric, D2% to the CTV. The maximum observed root mean square (RMS) difference between corresponding metrics was 4.3 GyRBE (8% of prescription) for D1cc to optic chiasm. DSC were 0.90, 0.93, and 0.88 for the 50%, 75%, and 95% isodose lines, respectively. LETD -volume metrics significantly differed in all but one metric, L0.1cc of the brainstem. The maximum observed difference in RMS differences for LETD metrics was 1.0 keV/μm for L0.1cc to brainstem. CONCLUSIONS We have devised the first three-dimensional dose and LETD -prediction model for cranial proton radiation therapy has been developed. Dose accuracy compared favorably with that of previously published models in other treatment sites. The agreement in LETD supports future investigations with biological doses in mind to enable the full potential of KBP in proton therapy.
Collapse
Affiliation(s)
- Fakhriddin Pirlepesov
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Lydia Wilson
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Vadim P. Moskvin
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Alex Breuer
- Department of Pathology, St. Jude Children’s
Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678
| | - Franz Parkins
- Department of Information Services, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - John T. Lucas
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Thomas E. Merchant
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| | - Austin M. Faught
- Department of Radiation Oncology, St. Jude
Children’s Research Hospital, 262 Danny Thomas Place, Memphis, TN,
38105-3678
| |
Collapse
|
30
|
Kim Y, Kim JS, Cho S. Feasibility study of using triple-energy CT images for improving stopping power estimation. NUCLEAR ENGINEERING AND TECHNOLOGY 2022. [DOI: 10.1016/j.net.2022.12.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
31
|
Radiation as a Tool against Neurodegeneration-A Potential Treatment for Amyloidosis in the Central Nervous System. Int J Mol Sci 2022; 23:ijms232012265. [PMID: 36293118 PMCID: PMC9603404 DOI: 10.3390/ijms232012265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 10/07/2022] [Accepted: 10/12/2022] [Indexed: 11/20/2022] Open
Abstract
Radiotherapy (RT) is a relatively safe and established treatment for cancer, where the goal is to kill tumoral cells with the lowest toxicity to healthy tissues. Using it for disorders involving cell loss is counterintuitive. However, ionizing radiation has a hormetic nature: it can have deleterious or beneficial effects depending on how it is applied. Current evidence indicates that radiation could be a promising treatment for neurodegenerative disorders involving protein misfolding and amyloidogenesis, such as Alzheimer's or Parkinson's diseases. Low-dose RT can trigger antioxidant, anti-inflammatory and tissue regeneration responses. RT has been used to treat peripheral amyloidosis, which is very similar to other neurodegenerative disorders from a molecular perspective. Ionizing radiation prevents amyloid formation and other hallmarks in cell cultures, animal models and pilot clinical trials. Although some hypotheses have been formulated, the mechanism of action of RT on systemic amyloid deposits is still unclear, and uncertainty remains regarding its impact in the central nervous system. However, new RT modalities such as low-dose RT, FLASH, proton therapy or nanoparticle-enhanced RT could increase biological effects while reducing toxicity. Current evidence indicates that the potential of RT to treat neurodegeneration should be further explored.
Collapse
|
32
|
Bright SJ, Flint DB, Martinus DKJ, Turner BX, Manandhar M, Ben Kacem M, McFadden CH, Yap TA, Shaitelman SF, Sawakuchi GO. Targeted Inhibition of DNA-PKcs, ATM, ATR, PARP, and Rad51 Modulate Response to X Rays and Protons. Radiat Res 2022; 198:336-346. [PMID: 35939823 PMCID: PMC9648665 DOI: 10.1667/rade-22-00040.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Accepted: 07/05/2022] [Indexed: 11/03/2022]
Abstract
Small molecule inhibitors are currently in preclinical and clinical development for the treatment of selected cancers, particularly those with existing genetic alterations in DNA repair and DNA damage response (DDR) pathways. Keen interest has also been expressed in combining such agents with other targeted antitumor strategies such as radiotherapy. Radiotherapy exerts its cytotoxic effects primarily through DNA damage-induced cell death; therefore, inhibiting DNA repair and the DDR should lead to additive and/or synergistic radiosensitizing effects. In this study we screened the response to X-ray or proton radiation in cell lines treated with DDR inhibitors (DDRis) targeting ATM, ATR, DNA-PKcs, Rad51, and PARP, with survival metrics established using clonogenic assays. We observed that DDRis generate significant radiosensitization in cancer and primary cells derived from normal tissue. Existing genetic defects in cancer cells appear to be an important consideration when determining the optimal inhibitor to use for synergistic combination with radiation. We also show that while greater radiosensitization can be achieved with protons (9.9 keV/µm) combined with DDRis, the relative biological effectiveness is unchanged or in some cases reduced. Our results indicate that while targeting the DDR can significantly radiosensitize cancer cells to such combinations, normal cells may also be equally or more severely affected, depending on the DDRi used. These data highlight the importance of identifying genetic defects as predictive biomarkers of response for combination treatment.
Collapse
Affiliation(s)
- Scott J. Bright
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - David B. Flint
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - David K. J. Martinus
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas
| | - Broderick X. Turner
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas
| | - Mandira Manandhar
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Mariam Ben Kacem
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Conor H. McFadden
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Timothy A. Yap
- Department of Investigational Cancer Therapeutics (Phase I Clinical Trials Program), Division of Cancer Medicine; Khalifa Institute for Personalized Cancer Therapy; Department of Thoracic/Head and Neck Medical Oncology; and The Institute for Applied Cancer Science. The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Simona F. Shaitelman
- Department of Radiation Oncology, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Gabriel O. Sawakuchi
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas
| |
Collapse
|
33
|
Faught AM, Wilson LJ, Gargone M, Pirlepesov F, Moskvin VP, Hua C. Treatment-planning approaches to intensity modulated proton therapy and the impact on dose-weighted linear energy transfer. J Appl Clin Med Phys 2022; 24:e13782. [PMID: 36161765 PMCID: PMC9859995 DOI: 10.1002/acm2.13782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 07/13/2022] [Accepted: 08/16/2022] [Indexed: 01/26/2023] Open
Abstract
PURPOSE We quantified the effect of various forward-based treatment-planning strategies in proton therapy on dose-weighted linear energy transfer (LETd). By maintaining the dosimetric quality at a clinically acceptable level, we aimed to evaluate the differences in LETd among various treatment-planning approaches and their practicality in minimizing biologic uncertainties associated with LETd. METHOD Eight treatment-planning strategies that are achievable in commercial treatment-planning systems were applied on a cylindrical water phantom and four pediatric brain tumor cases. Each planning strategy was compared to either an opposed lateral plan (phantom study) or original clinical plan (patient study). Deviations in mean and maximum LETd from clinically acceptable dose distributions were compared. RESULTS In the phantom study, using a range shifter and altering the robust scenarios during optimization had the largest effect on the mean clinical target volume LETd, which was reduced from 4.5 to 3.9 keV/μm in both cases. Variations in the intersection angle between beams had the largest effect on LETd in a ring defined 3 to 5 mm outside the target. When beam intersection angles were reduced from opposed laterals (180°) to 120°, 90°, and 60°, corresponding maximum LETd increased from 7.9 to 8.9, 10.9, and 12.2 keV/μm, respectively. A clear trend in mean and maximum LETd variations in the clinical cases could not be established, though spatial distribution of LETd suggested a strong dependence on patient anatomy and treatment geometry. CONCLUSION Changes in LETd from treatment-plan setup follow intuitive trends in a controlled phantom experiment. Anatomical and other patient-specific considerations, however, can preclude generalizable strategies in clinical cases. For pediatric cranial radiation therapy, we recommend using opposed lateral treatment fields to treat midline targets.
Collapse
Affiliation(s)
- Austin M. Faught
- Department of Radiation OncologySt. Jude Children's Research HospitalMemphisTennesseeUSA
| | - Lydia J. Wilson
- Department of Radiation OncologySt. Jude Children's Research HospitalMemphisTennesseeUSA
| | - Melissa Gargone
- Department of Radiation OncologySt. Jude Children's Research HospitalMemphisTennesseeUSA
| | - Fakhriddin Pirlepesov
- Department of Radiation OncologySt. Jude Children's Research HospitalMemphisTennesseeUSA
| | - Vadim P. Moskvin
- Department of Radiation OncologySt. Jude Children's Research HospitalMemphisTennesseeUSA
| | - Chia‐Ho Hua
- Department of Radiation OncologySt. Jude Children's Research HospitalMemphisTennesseeUSA
| |
Collapse
|
34
|
Volz L, Sheng Y, Durante M, Graeff C. Considerations for Upright Particle Therapy Patient Positioning and Associated Image Guidance. Front Oncol 2022; 12:930850. [PMID: 35965576 PMCID: PMC9372451 DOI: 10.3389/fonc.2022.930850] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 06/17/2022] [Indexed: 11/16/2022] Open
Abstract
Particle therapy is a rapidly growing field in cancer therapy. Worldwide, over 100 centers are in operation, and more are currently in construction phase. The interest in particle therapy is founded in the superior target dose conformity and healthy tissue sparing achievable through the particles’ inverse depth dose profile. This physical advantage is, however, opposed by increased complexity and cost of particle therapy facilities. Particle therapy, especially with heavier ions, requires large and costly equipment to accelerate the particles to the desired treatment energy and steer the beam to the patient. A significant portion of the cost for a treatment facility is attributed to the gantry, used to enable different beam angles around the patient for optimal healthy tissue sparing. Instead of a gantry, a rotating chair positioning system paired with a fixed horizontal beam line presents a suitable cost-efficient alternative. Chair systems have been used already at the advent of particle therapy, but were soon dismissed due to increased setup uncertainty associated with the upright position stemming from the lack of dedicated image guidance systems. Recently, treatment chairs gained renewed interest due to the improvement in beam delivery, commercial availability of vertical patient CT imaging and improved image guidance systems to mitigate the problem of anatomical motion in seated treatments. In this review, economical and clinical reasons for an upright patient positioning system are discussed. Existing designs targeted for particle therapy are reviewed, and conclusions are drawn on the design and construction of chair systems and associated image guidance. Finally, the different aspects from literature are channeled into recommendations for potential upright treatment layouts, both for retrofitting and new facilities.
Collapse
Affiliation(s)
- Lennart Volz
- Biophysics, GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany.,Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Shanghai, China
| | - Yinxiangzi Sheng
- Biophysics, GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany.,Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Shanghai, China
| | - Marco Durante
- Biophysics, GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany.,Institute of Condensed Matter Physics, Technical University of Darmstadt, Darmstadt, Germany
| | - Christian Graeff
- Biophysics, GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany.,Institute of Electrical Engineering and Information Technology, Technical University of Darmstadt, Darmstadt, Germany
| |
Collapse
|
35
|
Mairani A, Mein S, Blakely E, Debus J, Durante M, Ferrari A, Fuchs H, Georg D, Grosshans DR, Guan F, Haberer T, Harrabi S, Horst F, Inaniwa T, Karger CP, Mohan R, Paganetti H, Parodi K, Sala P, Schuy C, Tessonnier T, Titt U, Weber U. Roadmap: helium ion therapy. Phys Med Biol 2022; 67. [PMID: 35395649 DOI: 10.1088/1361-6560/ac65d3] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 04/08/2022] [Indexed: 12/16/2022]
Abstract
Helium ion beam therapy for the treatment of cancer was one of several developed and studied particle treatments in the 1950s, leading to clinical trials beginning in 1975 at the Lawrence Berkeley National Laboratory. The trial shutdown was followed by decades of research and clinical silence on the topic while proton and carbon ion therapy made debuts at research facilities and academic hospitals worldwide. The lack of progression in understanding the principle facets of helium ion beam therapy in terms of physics, biological and clinical findings persists today, mainly attributable to its highly limited availability. Despite this major setback, there is an increasing focus on evaluating and establishing clinical and research programs using helium ion beams, with both therapy and imaging initiatives to supplement the clinical palette of radiotherapy in the treatment of aggressive disease and sensitive clinical cases. Moreover, due its intermediate physical and radio-biological properties between proton and carbon ion beams, helium ions may provide a streamlined economic steppingstone towards an era of widespread use of different particle species in light and heavy ion therapy. With respect to the clinical proton beams, helium ions exhibit superior physical properties such as reduced lateral scattering and range straggling with higher relative biological effectiveness (RBE) and dose-weighted linear energy transfer (LETd) ranging from ∼4 keVμm-1to ∼40 keVμm-1. In the frame of heavy ion therapy using carbon, oxygen or neon ions, where LETdincreases beyond 100 keVμm-1, helium ions exhibit similar physical attributes such as a sharp lateral penumbra, however, with reduced radio-biological uncertainties and without potentially spoiling dose distributions due to excess fragmentation of heavier ion beams, particularly for higher penetration depths. This roadmap presents an overview of the current state-of-the-art and future directions of helium ion therapy: understanding physics and improving modeling, understanding biology and improving modeling, imaging techniques using helium ions and refining and establishing clinical approaches and aims from learned experience with protons. These topics are organized and presented into three main sections, outlining current and future tasks in establishing clinical and research programs using helium ion beams-A. Physics B. Biological and C. Clinical Perspectives.
Collapse
Affiliation(s)
- Andrea Mairani
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,National Centre of Oncological Hadrontherapy (CNAO), Medical Physics, Pavia, Italy.,Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Stewart Mein
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.,German Cancer Consortium (DKTK) Core-Center Heidelberg, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Eleanor Blakely
- Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, Berkeley, CA, United States of America
| | - Jürgen Debus
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.,German Cancer Consortium (DKTK) Core-Center Heidelberg, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg University and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Marco Durante
- GSI Helmholtzzentrum für Schwerionenforschung, D-64291 Darmstadt, Germany.,Technische Universität Darmstadt, Institut für Physik Kondensierter Materie, Darmstadt, Germany
| | - Alfredo Ferrari
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Hermann Fuchs
- Division of Medical Physics, Department of Radiation Oncology, Medical University of Vienna, Austria.,MedAustron Ion Therapy Center, Wiener Neustadt, Austria
| | - Dietmar Georg
- Division of Medical Physics, Department of Radiation Oncology, Medical University of Vienna, Austria.,MedAustron Ion Therapy Center, Wiener Neustadt, Austria
| | - David R Grosshans
- The University of Texas MD Anderson cancer Center, Houston, Texas, United States of America
| | - Fada Guan
- The University of Texas MD Anderson cancer Center, Houston, Texas, United States of America.,Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT, 06510, United States of America
| | - Thomas Haberer
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Semi Harrabi
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.,German Cancer Consortium (DKTK) Core-Center Heidelberg, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg University and German Cancer Research Center (DKFZ), Heidelberg, Germany.,National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Felix Horst
- GSI Helmholtzzentrum für Schwerionenforschung, D-64291 Darmstadt, Germany
| | - Taku Inaniwa
- Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, QST, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.,Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Christian P Karger
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.,Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Radhe Mohan
- The University of Texas MD Anderson cancer Center, Houston, Texas, United States of America
| | - Harald Paganetti
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, United States of America.,Harvard Medical School, Boston, United States of America
| | - Katia Parodi
- Ludwig-Maximilians-Universität München, Department of Experimental Physics-Medical Physics, Munich, Germany
| | - Paola Sala
- Ludwig-Maximilians-Universität München, Department of Experimental Physics-Medical Physics, Munich, Germany
| | - Christoph Schuy
- GSI Helmholtzzentrum für Schwerionenforschung, D-64291 Darmstadt, Germany
| | - Thomas Tessonnier
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Uwe Titt
- The University of Texas MD Anderson cancer Center, Houston, Texas, United States of America
| | - Ulrich Weber
- GSI Helmholtzzentrum für Schwerionenforschung, D-64291 Darmstadt, Germany
| |
Collapse
|
36
|
Proton Therapy in the Management of Hepatocellular Carcinoma. Cancers (Basel) 2022; 14:cancers14122900. [PMID: 35740567 PMCID: PMC9220794 DOI: 10.3390/cancers14122900] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 05/29/2022] [Accepted: 06/07/2022] [Indexed: 12/04/2022] Open
Abstract
Simple Summary Radiation therapy is among the locoregional therapy modalities used to treat unresectable or medically inoperable hepatocellular carcinoma (HCC). Proton radiation therapy plays a major role in the treatment of HCC, especially when liver toxicity is a concern. The aim of this review is to provide a concise and comprehensive summary on the use of proton therapy in the management of HCC. Abstract Proton radiation therapy plays a central role in the treatment of hepatocellular carcinoma (HCC). Because of the near-zero exit dose and improved sparing of normal liver parenchyma, protons are being used even in challenging scenarios, including larger or multifocal liver tumors, and those associated with vascular tumor thrombus. There is a mounting level of evidence that suggests that protons are superior to photons in terms of survival and toxicity outcomes, specifically the progression to liver failure. A randomized controlled trial comparing protons to photons is currently underway to verify this hypothesis.
Collapse
|
37
|
Kobeissi JM, Simone CB, Hilal L, Wu AJ, Lin H, Crane CH, Hajj C. Proton Therapy in the Management of Luminal Gastrointestinal Cancers: Esophagus, Stomach, and Anorectum. Cancers (Basel) 2022; 14:cancers14122877. [PMID: 35740544 PMCID: PMC9221464 DOI: 10.3390/cancers14122877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 05/28/2022] [Accepted: 06/07/2022] [Indexed: 11/29/2022] Open
Abstract
Simple Summary Radiation treatment plays a major role in the management of luminal gastrointestinal cancers, mainly esophageal and anorectal cancers. There is a growing interest in the application of protons for gastrointestinal cancers, mainly owing to its dosimetric characteristics in decreasing dose to nearby organs at risk. We present here an up-to-date comprehensive review of the dosimetric and clinical literature on the use of proton therapy in the management of luminal gastrointestinal cancers. Abstract While the role of proton therapy in gastric cancer is marginal, its role in esophageal and anorectal cancers is expanding. In esophageal cancer, protons are superior in sparing the organs at risk, as shown by multiple dosimetric studies. Literature is conflicting regarding clinical significance, but the preponderance of evidence suggests that protons yield similar or improved oncologic outcomes to photons at a decreased toxicity cost. Similarly, protons have improved sparing of the organs at risk in anorectal cancers, but clinical data is much more limited to date, and toxicity benefits have not yet been shown clinically. Large, randomized trials are currently underway for both disease sites.
Collapse
Affiliation(s)
- Jana M. Kobeissi
- Department of Radiation Oncology, School of Medicine, American University of Beirut Medical Center, Beirut 1007, Lebanon; (J.M.K.); (L.H.)
| | - Charles B. Simone
- Department of Radiation Oncology, New York Proton Center, New York, NY 10035, USA; (C.B.S.II); (H.L.)
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10027, USA; (A.J.W.); (C.H.C.)
| | - Lara Hilal
- Department of Radiation Oncology, School of Medicine, American University of Beirut Medical Center, Beirut 1007, Lebanon; (J.M.K.); (L.H.)
| | - Abraham J. Wu
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10027, USA; (A.J.W.); (C.H.C.)
| | - Haibo Lin
- Department of Radiation Oncology, New York Proton Center, New York, NY 10035, USA; (C.B.S.II); (H.L.)
| | - Christopher H. Crane
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10027, USA; (A.J.W.); (C.H.C.)
| | - Carla Hajj
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10027, USA; (A.J.W.); (C.H.C.)
- Correspondence:
| |
Collapse
|
38
|
Kobeissi JM, Simone CB, Lin H, Hilal L, Hajj C. Proton Therapy in the Management of Pancreatic Cancer. Cancers (Basel) 2022; 14:cancers14112789. [PMID: 35681769 PMCID: PMC9179382 DOI: 10.3390/cancers14112789] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 06/01/2022] [Accepted: 06/01/2022] [Indexed: 02/04/2023] Open
Abstract
Simple Summary Radiation treatment plays a pivotal a role in the management of pancreatic cancer, mainly in the neoadjuvant setting for borderline resectable tumors and in the definitive setting for unresectable localized disease. Most of the studies on pancreatic cancer use photon-based radiation therapy modalities. However, there is a growing interest in the application of protons therapy for gastrointestinal cancers. This review summarizes the literature on the use of proton therapy in the management of pancreatic cancer. Abstract Radiation therapy plays a central role in the treatment of pancreatic cancer. While generally shown to be feasible, proton irradiation, particularly when an ablative dose is planned, remains a challenge, especially due to tumor motion and the proximity to organs at risk, like the stomach, duodenum, and bowel. Clinically, standard doses of proton radiation treatment have not been shown to be statistically different from photon radiation treatment in terms of oncologic outcomes and toxicity rates as per non-randomized comparative studies. Fractionation schedules and concurrent chemotherapy combinations are yet to be optimized for proton therapy and are the subject of ongoing trials.
Collapse
Affiliation(s)
- Jana M. Kobeissi
- Department of Radiation Oncology, School of Medicine, American University of Beirut Medical Center, Beirut 1107, Lebanon; (J.M.K.); (L.H.)
| | - Charles B. Simone
- Department of Radiation Oncology, New York Proton Center, New York, NY 10035, USA; (C.B.S.II); (H.L.)
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10027, USA
| | - Haibo Lin
- Department of Radiation Oncology, New York Proton Center, New York, NY 10035, USA; (C.B.S.II); (H.L.)
| | - Lara Hilal
- Department of Radiation Oncology, School of Medicine, American University of Beirut Medical Center, Beirut 1107, Lebanon; (J.M.K.); (L.H.)
| | - Carla Hajj
- Department of Radiation Oncology, New York Proton Center, New York, NY 10035, USA; (C.B.S.II); (H.L.)
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10027, USA
- Correspondence:
| |
Collapse
|
39
|
Heuchel L, Hahn C, Pawelke J, Sørensen BS, Dosanjh M, Lühr A. Clinical use and future requirements of relative biological effectiveness: survey among all european proton therapy centres. Radiother Oncol 2022; 172:134-139. [PMID: 35605747 DOI: 10.1016/j.radonc.2022.05.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 04/29/2022] [Accepted: 05/15/2022] [Indexed: 01/10/2023]
Abstract
BACKGROUND AND PURPOSE The relative biological effectiveness (RBE) varies along the treatment field. However, in clinical practice, a constant RBE of 1.1 is assumed, which can result in undesirable side effects. This study provides an accurate overview of current clinical practice for considering proton RBE in Europe. MATERIALS AND METHODS A survey was devised and sent to all proton therapy centres in Europe that treat patients. The online questionnaire consisted of 39 questions addressing various aspects of RBE consideration in clinical practice, including treatment planning, patient follow-up and future demands. RESULTS All 25 proton therapy centres responded. All centres prescribed a constant RBE of 1.1, but also applied measures (except for one eye treatment centre) to counteract variable RBE effects such as avoiding beams stopping inside or in front of an organ at risk and putting restrictions on the minimum number and opening angle of incident beams for certain treatment sites. For the future, most centres (16) asked for more retrospective or prospective outcome studies investigating the potential effect of the effect of a variable RBE. To perform such studies, 18 centres asked for LET and RBE calculation and visualisation tools developed by treatment planning system vendors. CONCLUSION All European proton centres are aware of RBE variability but comply with current guidelines of prescribing a constant RBE. However, they actively mitigate uncertainty and risk of side effects resulting from increased RBE by applying measures and restrictions during treatment planning. To change RBE-related clinical guidelines in the future more clinical data on RBE are explicitly demanded.
Collapse
Affiliation(s)
- Lena Heuchel
- Department of Physics, TU Dortmund University, Germany
| | - Christian Hahn
- Department of Physics, TU Dortmund University, Germany; OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Germany
| | - Jörg Pawelke
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Germany; Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology - OncoRay, Germany
| | - Brita Singers Sørensen
- Department of Experimental Clinical Oncology, Aarhus University Hospital, Denmark; Danish Center for Particle Therapy, DCPT, Aarhus University Hospital, Denmark
| | - Manjit Dosanjh
- Department of Physics, University of Oxford, UK; CERN, Geneva, Switzerland
| | - Armin Lühr
- Department of Physics, TU Dortmund University, Germany.
| |
Collapse
|
40
|
Parisi A, Furutani KM, Beltran CJ. On the calculation of the relative biological effectiveness of ion radiation therapy using a biological weighting function, the microdosimetric kinetic model (MKM) and subsequent corrections (non-Poisson MKM and modified MKM). Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac5fdf] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 03/22/2022] [Indexed: 12/31/2022]
Abstract
Abstract
Objective. To investigate similarities and differences in the formalism, processing, and the results of relative biological effectiveness (RBE) calculations with a biological weighting function (BWF), the microdosimetric kinetic model (MKM) and subsequent modifications (non-Poisson MKM, modified MKM). This includes: (a) the extension of the V79-RBE10% BWF to model the RBE for other clonogenic survival levels; (b) a novel implementation of MKMs as weighting functions; (c) a benchmark against Chinese Hamster lung fibroblast (V79) in vitro data; (d) a study on the effect of pre- or post- processing the average biophysical quantities used for the RBE calculations; (e) a possible modification of the modified MKM parameters to improve the model accuracy at high linear energy transfer (LET). Methodology. Lineal energy spectra were simulated for two spherical targets (diameter = 0.464 or 1.0 μm) using PHITS for 1H, 4He, 12C, 20Ne, 40Ar, 56Fe and 132Xe ions. The results of the in silico calculations were compared with published in vitro data. Main results. All models appear to underestimate the RBE
α
of hydrogen ions. All MKMs generally overestimate the RBE50%, RBE10% and RBE1% for ions with an LET greater than ∼200 keV μm−1. This overestimation is greater for small surviving fractions and is likely due to the assumption of a radiation-independent quadratic term of clonogenic survival (ß). The overall RBE trends seem to be best described by the novel ‘post-processing average’ implementation of the non-Poisson MKM. In case of calculations with the non-Poisson MKM, pre- or post- processing the average biophysical quantities affects the computed RBE values significantly. Significance. This study presents a systematic analysis of the formalism and results of widely used microdosimetric models of clonogenic survival for ions relevant for cancer particle therapy and space radiation protection. Points for improvements were highlighted and will contribute to the development of upgraded biophysical models.
Collapse
|
41
|
Kaderka R, Liu KC, Liu L, VanderStraeten R, Liu TL, Lee KM, Tu YCE, MacEwan I, Simpson D, Urbanic J, Chang C. Toward automatic beam angle selection for pencil-beam scanning proton liver Treatments: A deep learning-based approach. Med Phys 2022; 49:4293-4304. [PMID: 35488864 DOI: 10.1002/mp.15676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Revised: 03/31/2022] [Accepted: 04/12/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Dose deposition characteristics of proton radiation can be advantageous over photons. Proton treatment planning however poses additional challenges for the planners. Proton therapy is usually delivered with only a small number of beam angles, and the quality of a proton treatment plan is largely determined by the beam angles employed. Finding the optimal beam angles for a proton treatment plan requires time and experience, motivating the investigation of automatic beam angle selection methods. PURPOSE A deep learning-based approach to automatic beam angle selection is proposed for proton pencil-beam scanning treatment planning of liver lesions. METHODS We cast beam-angle selection as a multi-label classification problem. To account for angular boundary discontinuity, the underlying convolution neural network is trained with the proposed Circular Earth Mover's Distance based regularization and multi-label circular-smooth label technique. Furthermore, an analytical algorithm emulating proton treatment planners' clinical practice is employed in post-processing to improve the output of the model. Forty-nine patients that received proton liver treatments between 2017 and 2020 were randomly divided into training (n = 31), validation (n = 7), and test sets (n = 11). AI-selected beam angles were compared with those angles selected by human planners, and the dosimetric outcome was investigated by creating plans using knowledge-based treatment planning. RESULTS For 7 of the 11 cases in the test set, AI-selected beam angles agreed with those chosen by human planners to within 20 degrees (median angle difference = 10°; mean = 18.6°). Moreover, out of the total 22 beam angles predicted by the model, 15 (68%) were within 10 degrees of the human-selected angles. The high correlation in beam angles resulted in comparable dosimetric statistics between proton treatment plans generated using AI- and human-selected angles. For the cases with beam angle differences exceeding 20°, the dosimetric analysis showed similar plan quality although with different emphases on organ-at-risk sparing. CONCLUSIONS This pilot study demonstrated the feasibility of a novel deep learning-based beam angle selection technique. Testing on liver cancer patients showed that the resulting plans were clinically viable with comparable dosimetric quality to those using human-selected beam angles. In tandem with auto-contouring and knowledge-based treatment planning tools, the proposed model could represent a pathway for nearly fully automated treatment planning in proton therapy. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Robert Kaderka
- Department of Radiation Medicine and Applied Sciences, University of California at San Diego, La Jolla, CA, 92121.,Department of Radiation Oncology, University of Miami, Miami, FL, 33136
| | | | - Lawrence Liu
- California Protons Cancer Therapy Center, San Diego, CA, 92121
| | | | | | | | | | - Iain MacEwan
- Department of Radiation Medicine and Applied Sciences, University of California at San Diego, La Jolla, CA, 92121.,California Protons Cancer Therapy Center, San Diego, CA, 92121
| | - Daniel Simpson
- Department of Radiation Medicine and Applied Sciences, University of California at San Diego, La Jolla, CA, 92121
| | - James Urbanic
- Department of Radiation Medicine and Applied Sciences, University of California at San Diego, La Jolla, CA, 92121.,California Protons Cancer Therapy Center, San Diego, CA, 92121
| | - Chang Chang
- Department of Radiation Medicine and Applied Sciences, University of California at San Diego, La Jolla, CA, 92121.,California Protons Cancer Therapy Center, San Diego, CA, 92121
| |
Collapse
|
42
|
Biological Dose Optimization for Particle Arc Therapy using Helium and Carbon Ions. Int J Radiat Oncol Biol Phys 2022; 114:334-348. [PMID: 35490991 DOI: 10.1016/j.ijrobp.2022.04.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 04/11/2022] [Accepted: 04/19/2022] [Indexed: 11/22/2022]
Abstract
PURPOSE To present biological dose optimization for particle arc therapy using helium and carbon ions. METHODS Treatment plan planning and optimization procedures were developed for spot-scanning hadron arc (SHArc) delivery using the RayStation TPS and a GPU-accelerated dose engine (†TPS-XXX). The SHArc optimization algorithm is applicable for charged particle beams and determines angle-dependencies for spot/energy selection with three main initiatives: i) achieve standard clinical optimization goals and constraints for target and OARs, ii) target dose robustness and iii) increasing LET in the target volume. Three patient cases previously treated at the †INSTITUTION-XXX were selected for evaluation of conventional versus arc delivery for the two clinical particle beams (helium [4He] and carbon [12C] ions): glioblastoma, prostate-adenocarcinoma and skull-base chordoma. Biological dose and dose-averaged linear energy transfer (LETd) distributions for SHArc were evaluated against conventional planning techniques (VMAT and IMPT2F) applying the modified microdosimetric kinetic model (mMKM) for considering bio-effect with (α/β)x=2Gy. Clinical viability and deliverability were assessed via evaluation of plan quality, robustness and irradiation time. RESULTS For all investigated patient cases, SHArc treatment optimizations met planning goals and constraints for target coverage and OARs, exhibiting acceptable target coverage and reduced normal tissue volumes with effective dose >10GyRBE compared to conventional 2F planning. For carbon ions, LETd was increased in the target volume from ∼40-60keV/µm to ∼80-140keV/µm for SHArc compared to conventional treatments. Favorable LETd distributions were possible with the SHArc approach, with maximum LETd in CTV/GTV and potential reductions of high-LET regions in normal tissues and OARs. Compared to VMAT, SHArc affords substantial reductions in normal tissue dose (40-70%). CONCLUSION SHArc therapy offers potential treatment benefits such as increased normal tissue sparing from higher doses >10GyRBE, enhanced target LETd, and potential reduction in high-LET components in OARs. Findings justify further development of robust SHArc treatment planning towards potential clinical translation.
Collapse
|
43
|
Ohsawa D, Hiroyama Y, Kobayashi A, Kusumoto T, Kitamura H, Hojo S, Kodaira S, Konishi T. DNA strand break induction of aqueous plasmid DNA exposed to 30 MeV protons at ultra-high dose rate. JOURNAL OF RADIATION RESEARCH 2022; 63:255-260. [PMID: 34952540 PMCID: PMC8944314 DOI: 10.1093/jrr/rrab114] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 10/22/2021] [Indexed: 06/14/2023]
Abstract
Radiation cancer therapy with ultra-high dose rate exposure, so called FLASH radiotherapy, appears to reduce normal tissue damage without compromising tumor response. The aim of this study was to clarify whether FLASH exposure of proton beam would be effective in reducing the DNA strand break induction. We applied a simple model system, pBR322 plasmid DNA in aqueous 1 × TE solution, where DNA single strand breaks (SSBs) and double strand breaks (DSBs) can be precisely quantified by gel electrophoresis. Plasmid DNA were exposed to 27.5 MeV protons in the conventional dose rate of 0.05 Gy/s (CONV) and ultra-high dose rate of 40 Gy/s (FLASH). With both dose rate, the kinetics of the SSB and DSB induction were proportional to absorbed dose. The SSB induction of FLASH was significantly less than CONV, which were 8.79 ± 0.14 (10-3 SSB per Gy per molecule) and 10.8 ± 0.68 (10-3 SSB per Gy per molecule), respectively. The DSB induction of FLASH was also slightly less than CONV, but difference was not significant. Altogether, 27.5 MeV proton beam at 40 Gy/s reduced SSB and not DSB, thus its effect may not be significant in reducing lethal DNA damage that become apparent in acute radiation effect.
Collapse
Affiliation(s)
- Daisuke Ohsawa
- Single Cell Radiation Biology Group, National Institutes for Quantum Science and Technology; 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
| | - Yota Hiroyama
- Single Cell Radiation Biology Group, National Institutes for Quantum Science and Technology; 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
- Graduate School of Health Sciences, Hirosaki University, 66-1 Hommachi, Hirosaki-shi, Aomori, 036-8564, Japan
| | - Alisa Kobayashi
- Single Cell Radiation Biology Group, National Institutes for Quantum Science and Technology; 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
- Electrostatic Accelerator Operation Section, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
| | - Tamon Kusumoto
- Single Cell Radiation Biology Group, National Institutes for Quantum Science and Technology; 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
- Radiation Measurement Research Group, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
| | - Hisashi Kitamura
- Radiation Measurement Research Group, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
| | - Satoru Hojo
- Cyclotron Operation Section, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
| | - Satoshi Kodaira
- Single Cell Radiation Biology Group, National Institutes for Quantum Science and Technology; 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
- Radiation Measurement Research Group, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inageku, Chiba, 263-8555, Japan
| | - Teruaki Konishi
- Corresponding author. Single Cell Radiation Biology Group, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inageku, Chiba, 263-8555 Japan, ; Tel.: +81-43-206-4695
| |
Collapse
|
44
|
Mein S, Kopp B, Vela A, Dutheil P, Lesueur P, Stefan D, Debus J, Haberer T, Abdollahi A, Mairani A, Tessonnier T. How can we consider variable RBE and LET d prediction during clinical practice? A pediatric case report at the Normandy Proton Therapy Centre using an independent dose engine. Radiat Oncol 2022; 17:23. [PMID: 35120547 PMCID: PMC8815260 DOI: 10.1186/s13014-021-01960-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 12/01/2021] [Indexed: 11/25/2022] Open
Abstract
Background To develop an auxiliary GPU-accelerated proton therapy (PT) dose and LETd engine for the IBA Proteus®ONE PT system. A pediatric low-grade glioma case study is reported using FRoG during clinical practice, highlighting potential treatment planning insights using variable RBE dose (DvRBE) and LETd as indicators for clinical decision making in PT. Methods The physics engine for FRoG has been modified for compatibility with Proteus®ONE PT centers. Subsequently, FRoG was installed and commissioned at NPTC. Dosimetric validation was performed against measurements and the clinical TPS, RayStation (RS-MC). A head patient cohort previously treated at NPTC was collected and FRoG forward calculations were compared against RS-MC for evaluation of 3D-Γ analysis and dose volume histogram (DVH) results. Currently, treatment design at NPTC is supported with fast variable RBE and LETd calculation and is reported in a representative case for pediatric low-grade glioma. Results Simple dosimetric tests against measurements of iso-energy layers and spread-out Bragg Peaks in water verified accuracy of FRoG and RS-MC. Among the patient cohort, average 3D-Γ applying 2%/2 mm, 3%/1.5 mm and 5%/1 mm were > 97%. DVH metrics for targets and OARs between FRoG and RayStation were in good agreement, with ∆D50,CTV and ∆D2,OAR both ⪅1%. The pediatric case report demonstrated implications of different beam arrangements on DvRBE and LETd distributions. From initial planning in RayStation sharing identical optimization constraints, FRoG analysis led to plan selection of the most conservative approach, i.e., minimized DvRBE,max and LETd,max in OARs, to avoid optical system toxicity effects (i.e., vision loss). Conclusion An auxiliary dose calculation system was successfully integrated into the clinical workflow at a Proteus®ONE IBA facility, in excellent agreement with measurements and RS-MC. FRoG may lead to further insight on DvRBE and LETd implications to help clinical decision making, better understand unexpected toxicities and establish novel clinical procedures with metrics currently absent from the standard clinical TPS.
Collapse
Affiliation(s)
- Stewart Mein
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), German Cancer Research Center (DKFZ), Heidelberg, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Ion-beam Therapy Center (HIT), In Neuenheimer Feld (INF) 450, DE, 69120, Heidelberg, Germany
| | - Benedikt Kopp
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), German Cancer Research Center (DKFZ), Heidelberg, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Ion-beam Therapy Center (HIT), In Neuenheimer Feld (INF) 450, DE, 69120, Heidelberg, Germany.,Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
| | - Anthony Vela
- Radiation Oncology Department, Centre François Baclesse, Caen, France
| | - Pauline Dutheil
- Radiation Oncology Department, Centre François Baclesse, Caen, France
| | - Paul Lesueur
- Radiation Oncology Department, Centre François Baclesse, Caen, France.,Radiation Oncology Department, Centre Guillaume Le Conquérant, Le Havre, France.,ISTCT UMR6030-CNRS, CEA, Université de Caen-Normandie, Equipe CERVOxy, Caen, France
| | - Dinu Stefan
- Radiation Oncology Department, Centre François Baclesse, Caen, France
| | - Jürgen Debus
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), German Cancer Research Center (DKFZ), Heidelberg, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Ion-beam Therapy Center (HIT), In Neuenheimer Feld (INF) 450, DE, 69120, Heidelberg, Germany
| | - Thomas Haberer
- Heidelberg Ion-beam Therapy Center (HIT), In Neuenheimer Feld (INF) 450, DE, 69120, Heidelberg, Germany
| | - Amir Abdollahi
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), German Cancer Research Center (DKFZ), Heidelberg, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Heidelberg Ion-beam Therapy Center (HIT), In Neuenheimer Feld (INF) 450, DE, 69120, Heidelberg, Germany
| | - Andrea Mairani
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Ion-beam Therapy Center (HIT), In Neuenheimer Feld (INF) 450, DE, 69120, Heidelberg, Germany.,National Centre of Oncological Hadrontherapy (CNAO), Medical Physics, Pavia, Italy
| | - Thomas Tessonnier
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, Heidelberg, Germany. .,Heidelberg Ion-beam Therapy Center (HIT), In Neuenheimer Feld (INF) 450, DE, 69120, Heidelberg, Germany. .,Radiation Oncology Department, Centre François Baclesse, Caen, France.
| |
Collapse
|
45
|
Planning benchmark study for SBRT of liver metastases: Results of the DEGRO/DGMP working group stereotactic radiotherapy and radiosurgery. Int J Radiat Oncol Biol Phys 2022; 113:214-227. [PMID: 35074434 DOI: 10.1016/j.ijrobp.2022.01.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 12/19/2021] [Accepted: 01/07/2022] [Indexed: 11/22/2022]
Abstract
PURPOSE To investigate, if liver SBRT treatment planning can be harmonized across different treatment planning systems, delivery techniques and institutions by using a specific prescription method and to minimize the knowledge gap concerning inter-system and inter-user differences. To provide best practice guidelines for all used techniques. METHODS A multiparametric specification of target dose (GTVD50%, GTVD0.1cc, GTVV90%, PTVV70%) with a prescription dose of GTVD50% = 3 × 20 Gy and OAR limits were distributed with CTs and structure sets from three liver metastases patients. Thirty-five institutions provided 132 treatment plans using different irradiation techniques. These plans were first analyzed for target and OAR doses. Four different renormalization methods were performed (PTVDmin, PTVD98%, PTVD2%, PTVDmax). The resulting 660 treatments plans were evaluated regarding target doses in order to study the effect of dose renormalization to different prescription methods. A relative scoring system was used for comparisons. RESULTS GTVD50% prescription can be performed in all systems. Treatment plan harmonization was overall successful with standard deviations for Dmax, PTVD98%, GTVD98% and PTVDmean of 1.6 Gy, 3.3 Gy, 1.9 Gy and 1.5 Gy, respectively. Primary analysis showed 55 major deviations from clinical goals in 132 plans, while in only <20% of deviations GTV/PTV dose was traded for meeting OAR limits. GTVD50% prescription produced the smallest deviation from target planning objectives and between techniques, followed by the PTVDmax, PTVD98%, PTVD2% and PTVDmin prescription. Deviations were significant for all combinations but for the PTVDmax prescription compared with GTVD50% and PTVD98%. Based on the various dose prescription methods, all systems significantly differed from each other, while GTVD50% and PTVD98% prescription showed the least differences between the systems. CONCLUSIONS This study showed the feasibility of harmonizing liver SBRT treatment plans across different treatment planning systems and delivery techniques when a sufficient set of clinical goals is given.
Collapse
|
46
|
Longarino FK, Tessonnier T, Mein S, Harrabi SB, Debus J, Stiller W, Mairani A. Dual-layer spectral CT for proton, helium, and carbon ion beam therapy planning of brain tumors. J Appl Clin Med Phys 2022; 23:e13465. [PMID: 34724327 PMCID: PMC8803296 DOI: 10.1002/acm2.13465] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 08/23/2021] [Accepted: 10/14/2021] [Indexed: 01/21/2023] Open
Abstract
Pretreatment computed tomography (CT) imaging is an essential component of the particle therapy treatment planning chain. Treatment planning and optimization with charged particles require accurate and precise estimations of ion beam range in tissues, characterized by the stopping power ratio (SPR). Reduction of range uncertainties arising from conventional CT-number-to-SPR conversion based on single-energy CT (SECT) imaging is of importance for improving clinical practice. Here, the application of a novel imaging and computational methodology using dual-layer spectral CT (DLCT) was performed toward refining patient-specific SPR estimates. A workflow for DLCT-based treatment planning was devised to evaluate SPR prediction for proton, helium, and carbon ion beam therapy planning in the brain. DLCT- and SECT-based SPR predictions were compared in homogeneous and heterogeneous anatomical regions. This study included eight patients scanned for diagnostic purposes with a DLCT scanner. For each patient, four different treatment plans were created, simulating tumors in different parts of the brain. For homogeneous anatomical regions, mean SPR differences of about 1% between the DLCT- and SECT-based approaches were found. In plans of heterogeneous anatomies, relative (absolute) proton range shifts of 0.6% (0.4 mm) in the mean and up to 4.4% (2.1 mm) at the distal fall-off were observed. In the investigated cohort, 12% of the evaluated organs-at-risk (OARs) presented differences in mean or maximum dose of more than 0.5 Gy (RBE) and up to 6.8 Gy (RBE) over the entire treatment. Range shifts and dose differences in OARs between DLCT and SECT in helium and carbon ion treatment plans were similar to protons. In the majority of investigated cases (75th percentile), SECT- and DLCT-based range estimations were within 0.6 mm. Nonetheless, the magnitude of patient-specific range deviations between SECT and DLCT was clinically relevant in heterogeneous anatomical sites, suggesting further study in larger, more diverse cohorts. Results indicate that patients with brain tumors may benefit from DLCT-based treatment planning.
Collapse
Affiliation(s)
- Friderike K. Longarino
- German Cancer Research Center (DKFZ)Clinical Cooperation Unit Radiation OncologyHeidelbergGermany
- Department of Radiation OncologyHeidelberg University HospitalHeidelbergGermany
- Department of Physics and AstronomyHeidelberg UniversityHeidelbergGermany
| | | | - Stewart Mein
- Department of Radiation OncologyHeidelberg University HospitalHeidelbergGermany
- Heidelberg Ion Beam Therapy Center (HIT)HeidelbergGermany
- German Cancer Research Center (DKFZ)Translational Radiation OncologyHeidelbergGermany
- National Center for Radiation Research in Oncology (NCRO)Heidelberg Institute of Radiation Oncology (HIRO)HeidelbergGermany
- National Center for Tumor Diseases (NCT)HeidelbergGermany
| | - Semi B. Harrabi
- Department of Radiation OncologyHeidelberg University HospitalHeidelbergGermany
- Heidelberg Ion Beam Therapy Center (HIT)HeidelbergGermany
- National Center for Radiation Research in Oncology (NCRO)Heidelberg Institute of Radiation Oncology (HIRO)HeidelbergGermany
- National Center for Tumor Diseases (NCT)HeidelbergGermany
| | - Jürgen Debus
- German Cancer Research Center (DKFZ)Clinical Cooperation Unit Radiation OncologyHeidelbergGermany
- Department of Radiation OncologyHeidelberg University HospitalHeidelbergGermany
- Heidelberg Ion Beam Therapy Center (HIT)HeidelbergGermany
- National Center for Radiation Research in Oncology (NCRO)Heidelberg Institute of Radiation Oncology (HIRO)HeidelbergGermany
- National Center for Tumor Diseases (NCT)HeidelbergGermany
- Partner Site HeidelbergGerman Cancer Consortium (DKTK)HeidelbergGermany
| | - Wolfram Stiller
- Diagnostic and Interventional Radiology (DIR)Heidelberg University HospitalHeidelbergGermany
| | - Andrea Mairani
- Department of Radiation OncologyHeidelberg University HospitalHeidelbergGermany
- Heidelberg Ion Beam Therapy Center (HIT)HeidelbergGermany
- National Center for Tumor Diseases (NCT)HeidelbergGermany
- Medical PhysicsNational Centre of Oncological Hadrontherapy (CNAO)PaviaItaly
| |
Collapse
|
47
|
Parisi A, Olko P, Swakon J, Horwacik T, Jablonski H, Malinowski L, Nowak T, Struelens L, Vanhavere F. Microdosimetric characterization of a clinical proton therapy beam: comparison between simulated lineal energy distributions in spherical water targets and experimental measurements with a silicon detector. Phys Med Biol 2021; 67. [PMID: 34933289 DOI: 10.1088/1361-6560/ac4563] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 12/21/2021] [Indexed: 11/12/2022]
Abstract
Objective Treatment planning based on computer simulations were proposed to account for the increase in the relative biological effectiveness (RBE) of proton radiotherapy beams near to the edges of the irradiated volume. Since silicon detectors could be used to validate the results of these simulations, it is important to explore the limitations of this comparison. Approach Microdosimetric measurements with a MicroPlus Bridge V2 silicon detector (thickness = 10 µm) were performed along the Bragg peak of a clinical proton beam. The lineal energy distributions, the dose mean values, and the RBE calculated with a biological weighting function were compared with simulations with PHITS (microdosimetric target = 1 µm water sphere), and published clonogenic survival in vitro RBE data for the V79 cell line. The effect of the silicon-to-water conversion was also investigated by comparing three different methodologies (conversion based on a single value, novel bin-to-bin conversions based on SRIM and PSTAR). Main results Mainly due to differences in the microdosimetric targets, the experimental dose-mean lineal energy and RBE values at the distal edge were respectively up to 53% and 28% lower than the simulated ones. Furthermore, the methodology chosen for the silicon-to-water conversion was proven to affect the dose mean lineal energy and the RBE10 up to 32% and 11% respectively. The best methodology to compensate for this underestimation was the bin-to-bin silicon-to-water conversion based on PSTAR. Significance This work represents the first comparison between PHITS-simulated lineal energy distributions in water targets and corresponding experimental spectra measured with silicon detectors. Furthermore, the effect of the silicon-to-water conversion on the RBE was explored for the first time. The proposed methodology based on the PSTAR bin-to-bin conversion appears to provide superior results with respect to commonly used single scaling factors and is recommended for future studies.
Collapse
Affiliation(s)
| | - Pawel Olko
- IFJ PAN, Walerego Eljasza Radzikowskiego 152, Krakow, 31-342, POLAND
| | - Jan Swakon
- IFJ PAN, Walerego Eljasza Radzikowskiego 152, Krakow, 31-342, POLAND
| | - Tomasz Horwacik
- IF PAN, Walerego Eljasza Radzikowskiego 152, Krakow, Kraków, 31-342, POLAND
| | - Hubert Jablonski
- IFJ PAN, Walerego Eljasza Radzikowskiego 152, Krakow, 31-342, POLAND
| | - Leszek Malinowski
- IFJ PAN, Walerego Eljasza Radzikowskiego 152, Krakow, 31-342, POLAND
| | - Tomasz Nowak
- IFJ PAN, Walerego Eljasza Radzikowskiego 152, Krakow, 31-342, POLAND
| | | | | |
Collapse
|
48
|
Yasui K, Muramatsu R, Kamomae T, Toshito T, Kawabata F, Hayashi N. Evaluating the usefulness of the direct density reconstruction algorithm for intensity modulated and passively scattered proton therapy: Validation using an anthropomorphic phantom. Phys Med 2021; 92:95-101. [PMID: 34891108 DOI: 10.1016/j.ejmp.2021.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 11/14/2021] [Accepted: 11/20/2021] [Indexed: 11/30/2022] Open
Abstract
PURPOSE Accurate calculation of the proton beam range inside a patient is an important topic in proton therapy. In recent times, a computed tomography (CT) image reconstruction algorithm was developed for treatment planning to reduce the impact of the variation of the CT number with changes in imaging conditions. In this study, we investigated the usefulness of this new reconstruction algorithm (DirectDensity™: DD) in proton therapy based on its comparison with filtered back projection (FBP). METHODS We evaluated the effects of variations in the X-ray tube potential and target size on the FBP- and DD-image values and investigated the usefulness of the DD algorithm based on the range variations and dosimetric quantity variations. RESULTS For X-ray tube potential variations, the range variation in the case of FBP was up to 12.5 mm (20.8%), whereas that of DD was up to 3.3 mm (5.6%). Meanwhile, for target size variations, the range variation in the case of FBP was up to 2.2 mm (2.5%), whereas that of DD was up to 0.9 mm (1.4%). Moreover, the variations observed in the case of DD were smaller than those of FBP for all dosimetric quantities. CONCLUSION The dose distributions obtained using DD were more robust against variations in the CT imaging conditions (X-ray tube potential and target size) than those obtained using FBP, and the range variations were often less than the dose calculation grid (2 mm). Therefore, the DD algorithm is effective in a robust workflow and reduces uncertainty in range calculations.
Collapse
Affiliation(s)
- Keisuke Yasui
- Fujita Health University, Faculty of Radiological Technology, School of Health Sciences, 1-98 Dengakugakubo Kutsukake-cho, Toyoake, Aichi 470-1192, Japan.
| | - Rie Muramatsu
- Nagoya Proton Therapy Center, Nagoya City University West Medical Center, 1-1-1 Hirate-cho Kita-ku, Nagoya, Aichi 462-8508, Japan
| | - Takeshi Kamomae
- Nagoya University Hospital, 65 Tsuruma-cho Shouwa-ku, Nagoya, Aichi 466-8560, Japan
| | - Toshiyuki Toshito
- Nagoya Proton Therapy Center, Nagoya City University West Medical Center, 1-1-1 Hirate-cho Kita-ku, Nagoya, Aichi 462-8508, Japan
| | - Fumitaka Kawabata
- Nagoya University Hospital, 65 Tsuruma-cho Shouwa-ku, Nagoya, Aichi 466-8560, Japan
| | - Naoki Hayashi
- Fujita Health University, Faculty of Radiological Technology, School of Health Sciences, 1-98 Dengakugakubo Kutsukake-cho, Toyoake, Aichi 470-1192, Japan
| |
Collapse
|
49
|
Yap J, De Franco A, Sheehy S. Future Developments in Charged Particle Therapy: Improving Beam Delivery for Efficiency and Efficacy. Front Oncol 2021; 11:780025. [PMID: 34956897 PMCID: PMC8697351 DOI: 10.3389/fonc.2021.780025] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 11/16/2021] [Indexed: 01/09/2023] Open
Abstract
The physical and clinical benefits of charged particle therapy (CPT) are well recognized. However, the availability of CPT and complete exploitation of dosimetric advantages are still limited by high facility costs and technological challenges. There are extensive ongoing efforts to improve upon these, which will lead to greater accessibility, superior delivery, and therefore better treatment outcomes. Yet, the issue of cost remains a primary hurdle as utility of CPT is largely driven by the affordability, complexity and performance of current technology. Modern delivery techniques are necessary but limited by extended treatment times. Several of these aspects can be addressed by developments in the beam delivery system (BDS) which determines the overall shaping and timing capabilities enabling high quality treatments. The energy layer switching time (ELST) is a limiting constraint of the BDS and a determinant of the beam delivery time (BDT), along with the accelerator and other factors. This review evaluates the delivery process in detail, presenting the limitations and developments for the BDS and related accelerator technology, toward decreasing the BDT. As extended BDT impacts motion and has dosimetric implications for treatment, we discuss avenues to minimize the ELST and overview the clinical benefits and feasibility of a large energy acceptance BDS. These developments support the possibility of advanced modalities and faster delivery for a greater range of treatment indications which could also further reduce costs. Further work to realize methodologies such as volumetric rescanning, FLASH, arc, multi-ion and online image guided therapies are discussed. In this review we examine how increased treatment efficiency and efficacy could be achieved with improvements in beam delivery and how this could lead to faster and higher quality treatments for the future of CPT.
Collapse
Affiliation(s)
- Jacinta Yap
- School of Physics, University of Melbourne, Melbourne, VIC, Australia
| | - Andrea De Franco
- IFMIF Accelerator Development Group, Rokkasho Fusion Institute, National Institutes for Quantum Science and Technology, Aomori, Japan
| | - Suzie Sheehy
- School of Physics, University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
50
|
Metallic Nanoparticles: A Useful Prompt Gamma Emitter for Range Monitoring in Proton Therapy? RADIATION 2021. [DOI: 10.3390/radiation1040025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
In clinical practice, dose delivery in proton therapy treatment is affected by uncertainties related to the range of the beam in the patient, which requires medical physicists to introduce safety margins on the penetration depth of the beam. Although this ensures an irradiation of the entire clinical target volume with the prescribed dose, these safety margins also lead to the exposure of nearby healthy tissues and a subsequent risk of side effects. Therefore, non-invasive techniques that allow for margin reduction through online monitoring of prompt gammas emitted along the proton tracks in the patient are currently under development. This study provides the proof-of-concept of metal-based nanoparticles, injected into the tumor, as a prompt gamma enhancer, helping in the beam range verification. It identifies the limitations of this application, suggesting a low feasibility in a realistic clinical scenario but opens some avenues for improvement.