1
|
Amirav I, Rabin N, Levi S, Har-Even Cohn R, Lior Y, Shiran S, Sagi L, Fatal A, Zvirin A, Honen Y, Lavie M, Kimmel R. Non-ionizing measurement and quantification of bell-shaped chests in spinal muscular atrophy: a pilot study. Front Pediatr 2024; 12:1256445. [PMID: 38374878 PMCID: PMC10876057 DOI: 10.3389/fped.2024.1256445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 01/22/2024] [Indexed: 02/21/2024] Open
Abstract
Background Spinal Muscular Atrophy (SMA) is manifested by deformation of the chest wall, including a bell-shaped chest. We determined the ability of a novel non-ionizing, non-volitional method to measure and quantify bell-shaped chests in SMA. Methods A 3D depth camera and a chest x-ray (CXR) were used to capture chest images in 14 SMA patients and 28 controls. Both methods measure the distance between two points, but measurements performed by 3D analysis allow for the consideration of the curve of a surface (geodesic measurements), whereas the CXR allows solely for the determination of the shortest path between two points, with no regard for the surface (Euclidean measurements). The ratio of the upper to lower chest distances was quantified to distinguish chest shape in imaging by both the 3D depth camera and the CXR, and the ratios were compared between healthy and SMA patients. Results The mean 3D Euclidean ratio of distances measured by 3D imaging was 1.00 in the control group and 0.92 in the SMA group (p = 0.01), the latter indicative of a bell-shaped chest. This result repeated itself in the ratio of geodesic measurements (0.99 vs. 0.89, respectively, p = 0.03). Conclusion The herein-described novel, noninvasive 3D method for measuring the upper and lower chest distances was shown to distinguish the bell-shaped chest configuration in patients with SMA from the chests of controls. This method bears several advantages over CXR and may be readily applicable in clinical settings that manage children with SMA.
Collapse
Affiliation(s)
- Israel Amirav
- Pediatric Pulmonology Unit, Dana-Dwek Children’s Hospital, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel
- Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Neta Rabin
- Pediatric Pulmonology Unit, Dana-Dwek Children’s Hospital, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel
- Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Sapir Levi
- Pediatric Pulmonology Unit, Dana-Dwek Children’s Hospital, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel
- Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Ronly Har-Even Cohn
- Pediatric Pulmonology Unit, Dana-Dwek Children’s Hospital, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel
- Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yotam Lior
- Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- Division of Anesthesia, Intensive Care, and Pain Management, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Shelly Shiran
- Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- Radiology Department, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Liora Sagi
- Pediatric Pulmonology Unit, Dana-Dwek Children’s Hospital, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel
- Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Aviva Fatal
- Pediatric Pulmonology Unit, Dana-Dwek Children’s Hospital, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel
- Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Alon Zvirin
- Department of Computer Sciences, The Technion, Israel Institute of Technology, Haifa, Israel
| | - Yaron Honen
- Department of Computer Sciences, The Technion, Israel Institute of Technology, Haifa, Israel
| | - Moran Lavie
- Pediatric Pulmonology Unit, Dana-Dwek Children’s Hospital, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel
- Affiliated to the Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Ron Kimmel
- Department of Computer Sciences, The Technion, Israel Institute of Technology, Haifa, Israel
- Department of Electrical and Computer Engineering, The Technion, Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
2
|
DiBlasi RM, Crandall CN, Engberg RJ, Bijlani K, Ledee D, Kajimoto M, Walther FJ. Evaluation of a Novel Dry Powder Surfactant Aerosol Delivery System for Use in Premature Infants Supported with Bubble CPAP. Pharmaceutics 2023; 15:2368. [PMID: 37896128 PMCID: PMC10609757 DOI: 10.3390/pharmaceutics15102368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 09/05/2023] [Accepted: 09/08/2023] [Indexed: 10/29/2023] Open
Abstract
Aerosolized lung surfactant therapy during nasal continuous positive airway pressure (CPAP) support avoids intubation but is highly complex, with reported poor nebulizer efficiency and low pulmonary deposition. The study objective was to evaluate particle size, operational compatibility, and drug delivery efficiency with various nasal CPAP interfaces and gas humidity levels of a synthetic dry powder (DP) surfactant aerosol delivered by a low-flow aerosol chamber (LFAC) inhaler combined with bubble nasal CPAP (bCPAP). A particle impactor characterized DP surfactant aerosol particle size. Lung pressures and volumes were measured in a preterm infant nasal airway and lung model using LFAC flow injection into the bCPAP system with different nasal prongs. The LFAC was combined with bCPAP and a non-heated passover humidifier. DP surfactant mass deposition within the nasal airway and lung was quantified for different interfaces. Finally, surfactant aerosol therapy was investigated using select interfaces and bCPAP gas humidification by active heating. Surfactant aerosol particle size was 3.68 µm. Lung pressures and volumes were within an acceptable range for lung protection with LFAC actuation and bCPAP. Aerosol delivery of DP surfactant resulted in variable nasal airway (0-20%) and lung (0-40%) deposition. DP lung surfactant aerosols agglomerated in the prongs and nasal airways with significant reductions in lung delivery during active humidification of bCPAP gas. Our findings show high-efficiency delivery of small, synthetic DP surfactant particles without increasing the potential risk for lung injury during concurrent aerosol delivery and bCPAP with passive humidification. Specialized prongs adapted to minimize extrapulmonary aerosol losses and nasal deposition showed the greatest lung deposition. The use of heated, humidified bCPAP gases compromised drug delivery and safety. Safety and efficacy of DP aerosol delivery in preterm infants supported with bCPAP requires more research.
Collapse
Affiliation(s)
- Robert M. DiBlasi
- Department of Respiratory Care Therapy, Seattle Children’s Hospital, Seattle, WA 98105, USA
- Center for Respiratory Biology and Therapeutics, Seattle Children’s Research Institute, Seattle, WA 98101, USA; (C.N.C.); (R.J.E.); (M.K.)
| | - Coral N. Crandall
- Center for Respiratory Biology and Therapeutics, Seattle Children’s Research Institute, Seattle, WA 98101, USA; (C.N.C.); (R.J.E.); (M.K.)
- Quality and Clinical Effectiveness, Seattle Children’s Hospital, Seattle, WA 98105, USA
- Center for Clinical and Translational Research, Seattle Children’s Research Institute, Seattle, WA 98101, USA
| | - Rebecca J. Engberg
- Center for Respiratory Biology and Therapeutics, Seattle Children’s Research Institute, Seattle, WA 98101, USA; (C.N.C.); (R.J.E.); (M.K.)
- Center for Clinical and Translational Research, Seattle Children’s Research Institute, Seattle, WA 98101, USA
| | - Kunal Bijlani
- Mechanical Engineering, Zewski Corporation, Magnolia, TX 77354, USA;
| | - Dolena Ledee
- Division of Cardiology, Department of Pediatrics, University of Washington, Seattle, WA 98195, USA;
| | - Masaki Kajimoto
- Center for Respiratory Biology and Therapeutics, Seattle Children’s Research Institute, Seattle, WA 98101, USA; (C.N.C.); (R.J.E.); (M.K.)
| | - Frans J. Walther
- Department of Pediatrics, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA;
- Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center, Torrance, CA 90502, USA
| |
Collapse
|
3
|
Frankfort MGH, Lauwers I, Pruijn EMC, Dijkstra SF, Boormans LHG, Schouten NA, van Donkelaar CC, Janssens HM. Minimizing Aerosol Leakage from Facemasks in the COVID-19 Pandemic. J Aerosol Med Pulm Drug Deliv 2023. [PMID: 37172274 DOI: 10.1089/jamp.2022.0036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023] Open
Abstract
Background: Aerosol therapies with vented facemasks are considered a risk for nosocomial transmission of viruses such as severe acute respiratory syndrome coronavirus 2. The transmission risk can be decreased by minimizing aerosol leakage and filtering the exhaled air. Objective: In this study, we determined which closed facemask designs show the least leakage. Methods: Smoke leakage was quantified during in- and exhalation in a closed system with expiration filter for three infant, six child, and six adult facemasks (three times each mask), using age-appropriate anatomical face models and breathing patterns. To assess leakage, smoke release was recorded and cumulative average pixel intensity (cAPI) was calculated. Results: In the adult group, aircushion edges resulted in less leakage than soft edges (cAPI: 407 ± 250 vs. 774 ± 152) (p = 0.004). The Intersurgical® Economy 5 mask (cAPI: 146 ± 87) also released less smoke than the Intersurgical® Clearlite 5 (cAPI: 748 ± 68) mask with the same size, but different geometry and edge type (p-value <0.05). Moreover, mask size had an effect, as there was a difference between Intersurgical® Economy 4 (cAPI: 708 ± 346) and 5, which have the same geometry but a different size (p-value <0.05). Finally, repositioning masks increased the standard deviations. Mask leakage was not dependent on breathing patterns within the child group. Conclusions: Mask leakage can be minimized by using a closed system with a well-fitting mask that is appropriately positioned. To decrease leakage, and therewith minimize potential viral transmission, selecting a well-fitting mask with an aircushion edge is to be recommended.
Collapse
Affiliation(s)
- Mylene G H Frankfort
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Iris Lauwers
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Emerentia M C Pruijn
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Sjoerd F Dijkstra
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Liza H G Boormans
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Nicolaas A Schouten
- TU/e Innovation Space, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Corrinus C van Donkelaar
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Hettie M Janssens
- Department of Pediatrics, Division of Respiratory Medicine and Allergology, Erasmus MC-Sophia Children's Hospital, University Medical Center Rotterdam, Rotterdam, The Netherlands
| |
Collapse
|
4
|
Katiyar SK, Gaur SN, Solanki RN, Sarangdhar N, Suri JC, Kumar R, Khilnani GC, Chaudhary D, Singla R, Koul PA, Mahashur AA, Ghoshal AG, Behera D, Christopher DJ, Talwar D, Ganguly D, Paramesh H, Gupta KB, Kumar T M, Motiani PD, Shankar PS, Chawla R, Guleria R, Jindal SK, Luhadia SK, Arora VK, Vijayan VK, Faye A, Jindal A, Murar AK, Jaiswal A, M A, Janmeja AK, Prajapat B, Ravindran C, Bhattacharyya D, D'Souza G, Sehgal IS, Samaria JK, Sarma J, Singh L, Sen MK, Bainara MK, Gupta M, Awad NT, Mishra N, Shah NN, Jain N, Mohapatra PR, Mrigpuri P, Tiwari P, Narasimhan R, Kumar RV, Prasad R, Swarnakar R, Chawla RK, Kumar R, Chakrabarti S, Katiyar S, Mittal S, Spalgais S, Saha S, Kant S, Singh VK, Hadda V, Kumar V, Singh V, Chopra V, B V. Indian Guidelines on Nebulization Therapy. Indian J Tuberc 2022; 69 Suppl 1:S1-S191. [PMID: 36372542 DOI: 10.1016/j.ijtb.2022.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Revised: 06/03/2022] [Accepted: 06/09/2022] [Indexed: 06/16/2023]
Abstract
Inhalational therapy, today, happens to be the mainstay of treatment in obstructive airway diseases (OADs), such as asthma, chronic obstructive pulmonary disease (COPD), and is also in the present, used in a variety of other pulmonary and even non-pulmonary disorders. Hand-held inhalation devices may often be difficult to use, particularly for children, elderly, debilitated or distressed patients. Nebulization therapy emerges as a good option in these cases besides being useful in the home care, emergency room and critical care settings. With so many advancements taking place in nebulizer technology; availability of a plethora of drug formulations for its use, and the widening scope of this therapy; medical practitioners, respiratory therapists, and other health care personnel face the challenge of choosing appropriate inhalation devices and drug formulations, besides their rational application and use in different clinical situations. Adequate maintenance of nebulizer equipment including their disinfection and storage are the other relevant issues requiring guidance. Injudicious and improper use of nebulizers and their poor maintenance can sometimes lead to serious health hazards, nosocomial infections, transmission of infection, and other adverse outcomes. Thus, it is imperative to have a proper national guideline on nebulization practices to bridge the knowledge gaps amongst various health care personnel involved in this practice. It will also serve as an educational and scientific resource for healthcare professionals, as well as promote future research by identifying neglected and ignored areas in this field. Such comprehensive guidelines on this subject have not been available in the country and the only available proper international guidelines were released in 1997 which have not been updated for a noticeably long period of over two decades, though many changes and advancements have taken place in this technology in the recent past. Much of nebulization practices in the present may not be evidence-based and even some of these, the way they are currently used, may be ineffective or even harmful. Recognizing the knowledge deficit and paucity of guidelines on the usage of nebulizers in various settings such as inpatient, out-patient, emergency room, critical care, and domiciliary use in India in a wide variety of indications to standardize nebulization practices and to address many other related issues; National College of Chest Physicians (India), commissioned a National task force consisting of eminent experts in the field of Pulmonary Medicine from different backgrounds and different parts of the country to review the available evidence from the medical literature on the scientific principles and clinical practices of nebulization therapy and to formulate evidence-based guidelines on it. The guideline is based on all possible literature that could be explored with the best available evidence and incorporating expert opinions. To support the guideline with high-quality evidence, a systematic search of the electronic databases was performed to identify the relevant studies, position papers, consensus reports, and recommendations published. Rating of the level of the quality of evidence and the strength of recommendation was done using the GRADE system. Six topics were identified, each given to one group of experts comprising of advisors, chairpersons, convenor and members, and such six groups (A-F) were formed and the consensus recommendations of each group was included as a section in the guidelines (Sections I to VI). The topics included were: A. Introduction, basic principles and technical aspects of nebulization, types of equipment, their choice, use, and maintenance B. Nebulization therapy in obstructive airway diseases C. Nebulization therapy in the intensive care unit D. Use of various drugs (other than bronchodilators and inhaled corticosteroids) by nebulized route and miscellaneous uses of nebulization therapy E. Domiciliary/Home/Maintenance nebulization therapy; public & health care workers education, and F. Nebulization therapy in COVID-19 pandemic and in patients of other contagious viral respiratory infections (included later considering the crisis created due to COVID-19 pandemic). Various issues in different sections have been discussed in the form of questions, followed by point-wise evidence statements based on the existing knowledge, and recommendations have been formulated.
Collapse
Affiliation(s)
- S K Katiyar
- Department of Tuberculosis & Respiratory Diseases, G.S.V.M. Medical College & C.S.J.M. University, Kanpur, Uttar Pradesh, India.
| | - S N Gaur
- Vallabhbhai Patel Chest Institute, University of Delhi, Respiratory Medicine, School of Medical Sciences and Research, Sharda University, Greater NOIDA, Uttar Pradesh, India
| | - R N Solanki
- Department of Tuberculosis & Chest Diseases, B. J. Medical College, Ahmedabad, Gujarat, India
| | - Nikhil Sarangdhar
- Department of Pulmonary Medicine, D. Y. Patil School of Medicine, Navi Mumbai, Maharashtra, India
| | - J C Suri
- Department of Pulmonary, Critical Care & Sleep Medicine, Vardhman Mahavir Medical College & Safdarjung Hospital, New Delhi, India
| | - Raj Kumar
- Vallabhbhai Patel Chest Institute, Department of Pulmonary Medicine, National Centre of Allergy, Asthma & Immunology; University of Delhi, Delhi, India
| | - G C Khilnani
- PSRI Institute of Pulmonary, Critical Care, & Sleep Medicine, PSRI Hospital, Department of Pulmonary Medicine & Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Dhruva Chaudhary
- Department of Pulmonary & Critical Care Medicine, Pt. Bhagwat Dayal Sharma Post Graduate Institute of Medical Sciences, Rohtak, Haryana, India
| | - Rupak Singla
- Department of Tuberculosis & Respiratory Diseases, National Institute of Tuberculosis & Respiratory Diseases (formerly L.R.S. Institute), Delhi, India
| | - Parvaiz A Koul
- Sher-i-Kashmir Institute of Medical Sciences, Srinagar, Jammu & Kashmir, India
| | - Ashok A Mahashur
- Department of Respiratory Medicine, P. D. Hinduja Hospital, Mumbai, Maharashtra, India
| | - A G Ghoshal
- National Allergy Asthma Bronchitis Institute, Kolkata, West Bengal, India
| | - D Behera
- Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - D J Christopher
- Department of Pulmonary Medicine, Christian Medical College, Vellore, Tamil Nadu, India
| | - Deepak Talwar
- Metro Centre for Respiratory Diseases, Noida, Uttar Pradesh, India
| | | | - H Paramesh
- Paediatric Pulmonologist & Environmentalist, Lakeside Hospital & Education Trust, Bengaluru, Karnataka, India
| | - K B Gupta
- Department of Tuberculosis & Respiratory Medicine, Pt. Bhagwat Dayal Sharma Post Graduate Institute of Medical Sciences Rohtak, Haryana, India
| | - Mohan Kumar T
- Department of Pulmonary, Critical Care & Sleep Medicine, One Care Medical Centre, Coimbatore, Tamil Nadu, India
| | - P D Motiani
- Department of Pulmonary Diseases, Dr. S. N. Medical College, Jodhpur, Rajasthan, India
| | - P S Shankar
- SCEO, KBN Hospital, Kalaburagi, Karnataka, India
| | - Rajesh Chawla
- Respiratory and Critical Care Medicine, Indraprastha Apollo Hospitals, New Delhi, India
| | - Randeep Guleria
- All India Institute of Medical Sciences, Department of Pulmonary Medicine & Sleep Disorders, AIIMS, New Delhi, India
| | - S K Jindal
- Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - S K Luhadia
- Department of Tuberculosis and Respiratory Medicine, Geetanjali Medical College and Hospital, Udaipur, Rajasthan, India
| | - V K Arora
- Indian Journal of Tuberculosis, Santosh University, NCR Delhi, National Institute of TB & Respiratory Diseases Delhi, India; JIPMER, Puducherry, India
| | - V K Vijayan
- Vallabhbhai Patel Chest Institute, Department of Pulmonary Medicine, University of Delhi, Delhi, India
| | - Abhishek Faye
- Centre for Lung and Sleep Disorders, Nagpur, Maharashtra, India
| | | | - Amit K Murar
- Respiratory Medicine, Cronus Multi-Specialty Hospital, New Delhi, India
| | - Anand Jaiswal
- Respiratory & Sleep Medicine, Medanta Medicity, Gurugram, Haryana, India
| | - Arunachalam M
- All India Institute of Medical Sciences, New Delhi, India
| | - A K Janmeja
- Department of Respiratory Medicine, Government Medical College, Chandigarh, India
| | - Brijesh Prajapat
- Pulmonary and Critical Care Medicine, Yashoda Hospital and Research Centre, Ghaziabad, Uttar Pradesh, India
| | - C Ravindran
- Department of TB & Chest, Government Medical College, Kozhikode, Kerala, India
| | - Debajyoti Bhattacharyya
- Department of Pulmonary Medicine, Institute of Liver and Biliary Sciences, Army Hospital (Research & Referral), New Delhi, India
| | | | - Inderpaul Singh Sehgal
- Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - J K Samaria
- Centre for Research and Treatment of Allergy, Asthma & Bronchitis, Department of Chest Diseases, IMS, BHU, Varanasi, Uttar Pradesh, India
| | - Jogesh Sarma
- Department of Pulmonary Medicine, Gauhati Medical College and Hospital, Guwahati, Assam, India
| | - Lalit Singh
- Department of Respiratory Medicine, SRMS Institute of Medical Sciences, Bareilly, Uttar Pradesh, India
| | - M K Sen
- Department of Respiratory Medicine, ESIC Medical College, NIT Faridabad, Haryana, India; Department of Pulmonary, Critical Care & Sleep Medicine, Vardhman Mahavir Medical College & Safdarjung Hospital, New Delhi, India
| | - Mahendra K Bainara
- Department of Pulmonary Medicine, R.N.T. Medical College, Udaipur, Rajasthan, India
| | - Mansi Gupta
- Department of Pulmonary Medicine, Sanjay Gandhi PostGraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Nilkanth T Awad
- Department of Pulmonary Medicine, Lokmanya Tilak Municipal Medical College, Mumbai, Maharashtra, India
| | - Narayan Mishra
- Department of Pulmonary Medicine, M.K.C.G. Medical College, Berhampur, Orissa, India
| | - Naveed N Shah
- Department of Pulmonary Medicine, Chest Diseases Hospital, Government Medical College, Srinagar, Jammu & Kashmir, India
| | - Neetu Jain
- Department of Pulmonary, Critical Care & Sleep Medicine, PSRI, New Delhi, India
| | - Prasanta R Mohapatra
- Department of Pulmonary Medicine & Critical Care, All India Institute of Medical Sciences, Bhubaneswar, Orissa, India
| | - Parul Mrigpuri
- Department of Pulmonary Medicine, Vallabhbhai Patel Chest Institute, University of Delhi, Delhi, India
| | - Pawan Tiwari
- School of Excellence in Pulmonary Medicine, NSCB Medical College, Jabalpur, Madhya Pradesh, India
| | - R Narasimhan
- Department of EBUS and Bronchial Thermoplasty Services at Apollo Hospitals, Chennai, Tamil Nadu, India
| | - R Vijai Kumar
- Department of Pulmonary Medicine, MediCiti Medical College, Hyderabad, Telangana, India
| | - Rajendra Prasad
- Vallabhbhai Patel Chest Institute, University of Delhi and U.P. Rural Institute of Medical Sciences & Research, Safai, Uttar Pradesh, India
| | - Rajesh Swarnakar
- Department of Respiratory, Critical Care, Sleep Medicine and Interventional Pulmonology, Getwell Hospital & Research Institute, Nagpur, Maharashtra, India
| | - Rakesh K Chawla
- Department of, Respiratory Medicine, Critical Care, Sleep & Interventional Pulmonology, Saroj Super Speciality Hospital, Jaipur Golden Hospital, Rajiv Gandhi Cancer Hospital, Delhi, India
| | - Rohit Kumar
- Department of Pulmonary, Critical Care & Sleep Medicine, Vardhman Mahavir Medical College & Safdarjung Hospital, New Delhi, India
| | - S Chakrabarti
- Department of Pulmonary, Critical Care & Sleep Medicine, Vardhman Mahavir Medical College & Safdarjung Hospital, New Delhi, India
| | | | - Saurabh Mittal
- Department of Pulmonary, Critical Care & Sleep Medicine, All India Institute of Medical Sciences, New Delhi, India
| | - Sonam Spalgais
- Department of Pulmonary Medicine, Vallabhbhai Patel Chest Institute, University of Delhi, Delhi, India
| | | | - Surya Kant
- Department of Respiratory (Pulmonary) Medicine, King George's Medical University, Lucknow, Uttar Pradesh, India
| | - V K Singh
- Centre for Visceral Mechanisms, Vallabhbhai Patel Chest Institute, University of Delhi, Delhi, India
| | - Vijay Hadda
- Department of Pulmonary Medicine & Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Vikas Kumar
- All India Institute of Medical Sciences, Raipur, Chhattisgarh, India
| | - Virendra Singh
- Mahavir Jaipuria Rajasthan Hospital, Jaipur, Rajasthan, India
| | - Vishal Chopra
- Department of Chest & Tuberculosis, Government Medical College, Patiala, Punjab, India
| | - Visweswaran B
- Interventional Pulmonology, Yashoda Hospitals, Hyderabad, Telangana, India
| |
Collapse
|
5
|
Bockstedte M, Xepapadeas AB, Spintzyk S, Poets CF, Koos B, Aretxabaleta M. Development of Personalized Non-Invasive Ventilation Interfaces for Neonatal and Pediatric Application Using Additive Manufacturing. J Pers Med 2022; 12:jpm12040604. [PMID: 35455720 PMCID: PMC9026706 DOI: 10.3390/jpm12040604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 03/31/2022] [Accepted: 04/06/2022] [Indexed: 11/16/2022] Open
Abstract
The objective of this study was to present a methodology and manufacturing workflow for non-invasive ventilation interfaces (NIV) for neonates and small infants. It aimed to procure a fast and feasible solution for personalized NIV produced in-house with the aim of improving fit and comfort for the patient. Three-dimensional scans were obtained by means of an intraoral (Trios 3) and a facial scanner (3dMd Flex System). Fusion 360 3D-modelling software was employed to automatize the design of the masks and their respective casting molds. These molds were additively manufactured by stereolithography (SLA) and fused filament fabrication (FFF) technologies. Silicone was poured into the molds to produce the medical device. In this way, patient individualized oronasal and nasal masks were produced. An automated design workflow and use of additive manufacturing enabled a fast and feasible procedure. Despite the cost for individualization likely being higher than for standard masks, a user-friendly workflow for in-house manufacturing of these medical appliances proved to have potential for improving NIV in neonates and infants, as well as increasing comfort.
Collapse
Affiliation(s)
- Marit Bockstedte
- Department of Orthodontics, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery within the University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany; (A.B.X.); (B.K.); (M.A.)
- Correspondence:
| | - Alexander B. Xepapadeas
- Department of Orthodontics, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery within the University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany; (A.B.X.); (B.K.); (M.A.)
| | - Sebastian Spintzyk
- Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany;
- ADMiRE Lab-Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, 9524 Villach, Austria
| | - Christian F. Poets
- Department of Neonatology, University Children’s Hospital, Calwerstr. 7, 72076 Tübingen, Germany;
| | - Bernd Koos
- Department of Orthodontics, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery within the University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany; (A.B.X.); (B.K.); (M.A.)
| | - Maite Aretxabaleta
- Department of Orthodontics, University Centre of Dentistry, Oral Medicine and Maxillofacial Surgery within the University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany; (A.B.X.); (B.K.); (M.A.)
| |
Collapse
|
6
|
Hovenier R, Goto L, Huysmans T, van Gestel M, Klein-Blommert R, Markhorst D, Dijkman C, Bem RA. Reduced Air Leakage During Non-Invasive Ventilation Using a Simple Anesthetic Mask With 3D-Printed Adaptor in an Anthropometric Based Pediatric Head-Lung Model. Front Pediatr 2022; 10:873426. [PMID: 35573957 PMCID: PMC9096156 DOI: 10.3389/fped.2022.873426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 03/29/2022] [Indexed: 11/16/2022] Open
Abstract
Non-invasive ventilation (NIV) is increasingly used in the support of acute respiratory failure in critically ill children admitted to the pediatric intensive care unit (PICU). One of the major challenges in pediatric NIV is finding an optimal fitting mask that limits air leakage, in particular for young children and those with specific facial features. Here, we describe the development of a pediatric head-lung model, based on 3D anthropometric data, to simulate pediatric NIV in a 1-year-old child, which can serve as a tool to investigate the effectiveness of NIV masks. Using this model, the primary aim of this study was to determine the extent of air leakage during NIV with our recently described simple anesthetic mask with a 3D-printed quick-release adaptor, as compared with a commercially available pediatric NIV mask. The simple anesthetic mask provided a better seal resulting in lower air leakage at various positive pressure levels as compared with the commercial mask. These data further support the use of the simple anesthetic mask as a reasonable alternative during pediatric NIV in the acute setting. Moreover, the pediatric head-lung model provides a promising tool to study the applicability and effectiveness of customized pediatric NIV masks in the future.
Collapse
Affiliation(s)
- Renée Hovenier
- Pediatric Intensive Care Unit, Emma Children's Hospital, Amsterdam University Medical Centers, Location AMC, Amsterdam, Netherlands.,Department of Technical Medicine, University of Twente, Enschede, Netherlands
| | - Lyè Goto
- Faculty of Industrial Design Engineering, Delft University of Technology, Delft, Netherlands
| | - Toon Huysmans
- Faculty of Industrial Design Engineering, Delft University of Technology, Delft, Netherlands.,Imec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium
| | - Monica van Gestel
- Pediatric Intensive Care Unit, Emma Children's Hospital, Amsterdam University Medical Centers, Location AMC, Amsterdam, Netherlands
| | - Rozalinde Klein-Blommert
- Pediatric Intensive Care Unit, Emma Children's Hospital, Amsterdam University Medical Centers, Location AMC, Amsterdam, Netherlands
| | - Dick Markhorst
- Pediatric Intensive Care Unit, Emma Children's Hospital, Amsterdam University Medical Centers, Location AMC, Amsterdam, Netherlands
| | - Coen Dijkman
- Department for Medical Innovation and Development, Amsterdam University Medical Centers, Location AMC, Amsterdam, Netherlands
| | - Reinout A Bem
- Pediatric Intensive Care Unit, Emma Children's Hospital, Amsterdam University Medical Centers, Location AMC, Amsterdam, Netherlands
| |
Collapse
|
7
|
The Variation in 3D Face Shapes of Dutch Children for Mask Design. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11156843] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The use of 3D anthropometric data of children’s heads and faces has great potential in the development of protective gear and medical products that need to provide a close fit in order to function well. Given the lack of detailed data of this kind, the aim of this study is to map the size and shape variation of Dutch children’s heads and faces and investigate possible implications for the design of a ventilation mask. In this study, a dataset of heads and faces of 303 Dutch children aged six months to seven years consisting of traditional measurements and 3D scans were analysed. A principal component analysis (PCA) of facial measurements was performed to map the variation of the children’s face shapes. The first principal component describes the overall size, whilst the second principal component captures the more width related variation of the face. After establishing a homology between the 3D scanned face shapes, a second principal component analysis was done on the point coordinates, revealing the most prominent variations in 3D shape within the sample.
Collapse
|
8
|
Corcoran TE. Measurements of deposited aerosol dose in infants and small children. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:595. [PMID: 33987293 PMCID: PMC8105848 DOI: 10.21037/atm-20-2045] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 07/19/2020] [Indexed: 11/06/2022]
Abstract
Pediatric patients are very dependent on inhaled aerosol medications. There are significant differences in how these aerosols deposit in the lungs of children vs. adults that may affect the efficacy of the therapies. Inefficient aerosol delivery to children, caused by factors such as high mouth and throat deposition during oral inhalation, significant losses within adjunct devices such as masks, and high rates of nasal deposition during cannula delivery, can lead to dosing that is difficult to control. Here we discuss the methods, such as deposition scintigraphy, that are used to assess inhaled dose in vivo and review previous studies where these techniques have been applied to measure dosing in children. This includes studies of nebulizers and metered dose inhalers and delivery through adjuncts such as facemasks and nasal cannulas. We discuss the factors that can lead to inefficient inhaled drug delivery and high levels of mouth and throat deposition in children. Finally, we propose areas of innovation to improve inhaled drug delivery to this population. There is a need for child-specific technologies for inhaled drug delivery. This includes the use of smart devices that can guide pediatric breathing patterns and better engage children during treatments, the use of smaller aerosols which are less likely to deposit in the upper airways after inhalation, and the design of better nasal cannula interfaces for aerosol delivery to infants.
Collapse
Affiliation(s)
- Timothy E Corcoran
- Division of Pulmonary, Allergy, and Critical Care Medicine, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, PA, USA
| |
Collapse
|
9
|
Ari A. A path to successful patient outcomes through aerosol drug delivery to children: a narrative review. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:593. [PMID: 33987291 PMCID: PMC8105845 DOI: 10.21037/atm-20-1682] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 07/03/2020] [Indexed: 11/06/2022]
Abstract
Although using aerosolized medications is a mainstay of treatment in children with asthma and other respiratory diseases, there are many issues in terms of device and interface selection, delivery technique and dosing, as well as patient and parental education that have not changed for half a century. Also, due to many aerosol devices and interfaces available on the market and the broad range of patient characteristics and requirements, providing effective aerosol therapy to children becomes a challenge. While aerosol delivery devices are equally effective, if they are age-appropriate and used correctly, the majority of aerosol devices require multiple steps to be used efficiently. Unfortunately, many children with pulmonary diseases have problems with the correct delivery technique and do not gain therapeutic benefits from therapy that result in poor disease management and increased healthcare costs. Therefore, the purpose of this paper is to review the current knowledge on aerosol delivery devices used in children and guide clinicians on the optimum device- and interface-selection, delivery technique, and dosing in this patient population. Strategies on how to deliver aerosolized medications in crying and distressed children and how to educate parents on aerosol therapy and promote patient adherence to prescribed medications are also provided. Future directions of aerosol therapy in children should focus on these issues and implement policies and clinical practices that highlight the potential solutions to these problems.
Collapse
Affiliation(s)
- Arzu Ari
- Department of Respiratory Care, Texas State University, Round Rock, TX, USA
| |
Collapse
|
10
|
Mulondo J, Maleni S, Aanyu-Tukamuhebwa H, Mupere E, Andama AO, Ng CH, Burkot S, Forgie EME, Mian Q, Bachman CM, Rummery G, Lieberman D, Bell D, Hawkes MT, Somoskovi A. Efficacy and safety of oxygen-sparing nasal reservoir cannula for treatment of pediatric hypoxemic pneumonia in Uganda: a pilot randomized clinical trial. BMC Pulm Med 2020; 20:230. [PMID: 32867735 PMCID: PMC7457357 DOI: 10.1186/s12890-020-01267-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Accepted: 08/18/2020] [Indexed: 11/23/2022] Open
Abstract
Background Oxygen is an essential therapy for hypoxemia but is scarce in low-income settings. Oxygen conserving devices optimize delivery, but to date have been designed for adults in high-income settings. Here we present the development and clinical pilot study of an oxygen-sparing nasal reservoir cannula (OSNRC) for pediatric use in low-income settings. Methods (1) Pre-clinical development of a novel OSNRC using a simulated respiratory circuit with metabolic simulator and anatomically accurate face-airway models. Simulated breathing waveforms were designed based on airway resistance, lung compliance, respiratory rate, and tidal volume of spontaneous breathing for three disease conditions. (2) Pilot, randomized, controlled, non-blinded, cross-over study of the OSNRC vs standard nasal cannula (SNC) among children hospitalized with hypoxemic pneumonia in Uganda. Eight children were randomized to OSNRC followed by SNC, and eight were randomized to SNC followed by OSNRC. Results The laboratory simulation showed that the OSNRC provided the same or higher fraction of inspired oxygen at approximately 2.5-times lower flow rate compared to SNC. The flow savings ratio exhibited a linear relationship with the OSNRC volume to tidal volume ratio with a slope that varied with breathing waveforms. The range of performance from different breathing waveforms defined a performance envelope of the OSNRC. Two mask sizes (30 mL and 50 mL) provided sufficient coverage for patients between the 3rd and 97th percentile in our targeted age range. In the clinical pilot study, the rise in capillary blood pCO2 was similar in the OSNRC and SNC groups, suggesting that the OSNRC was not associated with CO2 retention. There were no significant differences between OSNRC and SNC with respect to clinical adverse events, lactate levels, pH, and SpO2. The OSNRC group had a higher mean SpO2 than the SNC group (adjusted mean difference, 1.4, 95% confidence interval 1.1 to 1.8), showing oxygen delivery enhancement. Conclusion The OSNRC enhances oxygen delivery without causing CO2 retention and appears to be well-tolerated by pediatric patients. If safety, efficacy and tolerability are confirmed in larger trials, this device has the potential to optimize oxygen delivery in children in low-resource settings, reducing the global burden of pediatric pneumonia. Trial registration The trial was retrospectively registered (International Standard Registered Clinical/Social Study Number (ISRCTN): 15216845; Date of registration: 15 July 2020).
Collapse
Affiliation(s)
- Jerry Mulondo
- Infectious Diseases Research Collaboration, Kampala, Uganda
| | - Stella Maleni
- Infectious Diseases Research Collaboration, Kampala, Uganda
| | - Hellen Aanyu-Tukamuhebwa
- Department of Pediatrics and Child Health, Mulago National Referral Hospital and Makerere University, Kampala, Uganda
| | - Ezekiel Mupere
- Department of Pediatrics and Child Health, Mulago National Referral Hospital and Makerere University, Kampala, Uganda.,Department of Pediatrics, Makerere University College of Health Sciences, Kampala, Uganda
| | - Alfred Onubia Andama
- Department of Medicine, Makerere University College of Health Sciences, Kampala, Uganda
| | - Chin Hei Ng
- Intellectual Ventures, Global Good Fund, Bellevue, WA, USA
| | - Stephen Burkot
- Intellectual Ventures, Global Good Fund, Bellevue, WA, USA
| | - Ella M E Forgie
- Department of Pediatrics, University of Alberta, 3-588D Edmonton Clinic Health Academy, 11405 87 Ave NW, Edmonton, Alberta, T6G 1C9, Canada
| | - Qaasim Mian
- Department of Pediatrics, University of Alberta, 3-588D Edmonton Clinic Health Academy, 11405 87 Ave NW, Edmonton, Alberta, T6G 1C9, Canada
| | | | | | | | - David Bell
- Intellectual Ventures, Global Good Fund, Bellevue, WA, USA.,, Present address: Issaquah, USA
| | - Michael T Hawkes
- Department of Pediatrics, University of Alberta, 3-588D Edmonton Clinic Health Academy, 11405 87 Ave NW, Edmonton, Alberta, T6G 1C9, Canada. .,Department of Medical Microbiology and Immunology, University of Alberta, Edmonton, Canada. .,School of Public Health, University of Alberta, Edmonton, Canada. .,Stollery Science Lab, Edmonton, Canada. .,Women and Children's Health Research Institute, Edmonton, Canada.
| | - Akos Somoskovi
- Intellectual Ventures, Global Good Fund, Bellevue, WA, USA
| |
Collapse
|
11
|
Cazzola M, Cavalli F, Usmani OS, Rogliani P. Advances in pulmonary drug delivery devices for the treatment of chronic obstructive pulmonary disease. Expert Opin Drug Deliv 2020; 17:635-646. [DOI: 10.1080/17425247.2020.1739021] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Mario Cazzola
- Department of Experimental Medicine, Unit of Respiratory Medicine, University of Rome “Tor Vergata”, Rome, Italy
| | - Francesco Cavalli
- Department of Experimental Medicine, Unit of Respiratory Medicine, University of Rome “Tor Vergata”, Rome, Italy
| | - Omar S. Usmani
- Imperial College London and Royal Brompton Hospital, Airways Disease Section, National Heart and Lung Institute (NHLI), London, UK
| | - Paola Rogliani
- Department of Experimental Medicine, Unit of Respiratory Medicine, University of Rome “Tor Vergata”, Rome, Italy
| |
Collapse
|
12
|
Comment on "Optimizing the Delivery of Inhaled Medication for Respiratory Patients: The Role of Valved Holding Chambers". Can Respir J 2019; 2019:6475651. [PMID: 31428212 PMCID: PMC6683793 DOI: 10.1155/2019/6475651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Accepted: 06/27/2019] [Indexed: 12/01/2022] Open
|
13
|
Amirav I, Masumbuko CK, Hawkes MT, Solomon I, Aldar Y, Margalit G, Zvirin A, Honen Y, Sivasivugha ES, Kimmel R. 3D analysis of child facial dimensions for design of medical devices in low-middle income countries (LMIC). PLoS One 2019; 14:e0216548. [PMID: 31120916 PMCID: PMC6532852 DOI: 10.1371/journal.pone.0216548] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2018] [Accepted: 04/23/2019] [Indexed: 11/21/2022] Open
Abstract
Background Facial anthropometric data are scarce in African children. However, such data may be useful for the design of medical devices for high disease burden settings. The aim of this study was to obtain 3D facial anthropometric data of Congolese children aged 0–5 years. Methods & findings The faces of 287 Congolese children were successfully scanned using a portable structured-light based 3D video camera, suitable for field work in low- income settings. The images were analyzed using facial analysis algorithms. Normal growth curves were generated for the following facial dimensions: distance between nares and distance from subnasion to upper lip. At birth, 1 year, and 5 years of age the median dimensions were: 13·92, 14·66, and 17.60 mm, respectively for distance between nares, and 10·16, 10.88, and 13·79 mm, respectively for distance from subnasion to upper lip. Modeled facial contours conveniently clustered into three average sizes which could be used as templates for the design of medical instruments. Conclusion Capturing of 3D images of infants and young children in LMICs is feasible using portable cameras and computerized analysis. This method and these specific data on Congolese pediatric facial dimensions may assist in the design of appropriately sized medical devices (thermometers, face masks, pulse oximeters, etc.) for this population.
Collapse
Affiliation(s)
- Israel Amirav
- Department of Pediatrics, University of Alberta, Edmonton, Canada
| | - Claude Kasereka Masumbuko
- Association for Health Innovation in Africa, Butembo, Democratic Republic of the Congo
- Université Catholique du Graben, Butembo, Democratic Republic of the Congo
- * E-mail:
| | | | | | | | | | - Alon Zvirin
- Department of Computer Sciences, Technion University, Haifa, Israel
| | - Yaron Honen
- Department of Computer Sciences, Technion University, Haifa, Israel
| | | | - Ron Kimmel
- Department of Computer Sciences, Technion University, Haifa, Israel
| |
Collapse
|
14
|
Al-Subu AM, Hagen S, Eldridge M, Boriosi J. Aerosol therapy through high flow nasal cannula in pediatric patients. Expert Rev Respir Med 2017; 11:945-953. [PMID: 28994337 DOI: 10.1080/17476348.2017.1391095] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
INTRODUCTION High flow nasal cannula (HFNC) is increasingly used in pediatric patients suffering from respiratory failure. In some disease processes, patients may also benefit from aerosol therapy. Therefore, the use of HFNC to deliver aerosolized medications is a convenient and attractive option. Areas covered: This review aims to appraise available evidence concerning the efficiency of aerosol nebulized therapy delivery using HFNC in pediatric patients. Expert commentary: Delivery of aerosol particles is a very complex process and depends on the use of oxygen vs. heliox, nebulizer type and position within the HFNC circuit, patient's breathing effort and pattern, and more importantly cannula size and flow rates. Current in vitro evidence suggests the amount of aerosol delivery is likely to be very low at high flows. Clinical studies are limited in pediatric patients and given the limited clinical data, it is not possible to make recommendations for or against aerosol delivery through HFNC for pediatric patients.
Collapse
Affiliation(s)
- Awni M Al-Subu
- a Division of Pediatric Critical Care Medicine , University of Wisconsin-Madison , Madison , WI , USA
| | - Scott Hagen
- a Division of Pediatric Critical Care Medicine , University of Wisconsin-Madison , Madison , WI , USA
| | - Marlowe Eldridge
- a Division of Pediatric Critical Care Medicine , University of Wisconsin-Madison , Madison , WI , USA
| | - Juan Boriosi
- a Division of Pediatric Critical Care Medicine , University of Wisconsin-Madison , Madison , WI , USA
| |
Collapse
|
15
|
Ari A. Drug delivery interfaces: A way to optimize inhalation therapy in spontaneously breathing children. World J Clin Pediatr 2016; 5:281-287. [PMID: 27610343 PMCID: PMC4978620 DOI: 10.5409/wjcp.v5.i3.281] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2016] [Revised: 05/03/2016] [Accepted: 07/13/2016] [Indexed: 02/06/2023] Open
Abstract
There are several different types of drug delivery interfaces available on the market. Using the right interface for aerosol drug delivery to children is essential for effective inhalation therapy. However, clinicians usually focus on selecting the right drug-device combination and often overlook the importance of interface selection that lead to suboptimal drug delivery and therapeutic response in neonates and pediatrics. Therefore, it is necessary to critically assess each interface and understand its advantage and disadvantages in aerosol drug delivery to this patient population. The purpose of this paper is to provide a critical assessment of drug delivery interfaces used for the treatment of children with pulmonary diseases by emphasizing advantages and problems associated with their use during inhalation therapy.
Collapse
|
16
|
Clouse BJ, Jadcherla SR, Slaughter JL. Systematic Review of Inhaled Bronchodilator and Corticosteroid Therapies in Infants with Bronchopulmonary Dysplasia: Implications and Future Directions. PLoS One 2016; 11:e0148188. [PMID: 26840339 PMCID: PMC4740433 DOI: 10.1371/journal.pone.0148188] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Accepted: 01/14/2016] [Indexed: 12/03/2022] Open
Abstract
Background There is much debate surrounding the use of inhaled bronchodilators and corticosteroids for infants with bronchopulmonary dysplasia (BPD). Objective The objective of this systematic review was to identify strengths and knowledge gaps in the literature regarding inhaled therapies in BPD and guide future research to improve long-termoutcomes. Methods The databases of Academic Search Complete, CINAHL, PUBMED/MEDLINE, and Scopus were searched for studies that evaluated both acute and long-term clinical outcomes related to the delivery and therapeutic efficacy of inhaled beta-agonists, anticholinergics and corticosteroids in infants with developing and/or established BPD. Results Of 181 articles, 22 met inclusion criteria for review. Five evaluated beta-agonist therapies (n = 84, weighted gestational age (GA) of 27.1(26–30) weeks, weighted birth weight (BW) of 974(843–1310) grams, weighted post menstrual age (PMA) of 34.8(28–39) weeks, and weighted age of 53(15–86) days old at the time of evaluation). Fourteen evaluated inhaled corticosteroids (n = 2383, GA 26.2(26–29) weeks, weighted BW of 853(760–1114) grams, weighted PMA of 27.0(26–31) weeks, and weighted age of 6(0–45) days old at time of evaluation). Three evaluated combination therapies (n = 198, weighted GA of 27.8(27–29) weeks, weighted BW of 1057(898–1247) grams, weighted PMA of 30.7(29–45) weeks, and age 20(10–111) days old at time of evaluation). Conclusion Whether inhaled bronchodilators and inhaled corticosteroids improve long-term outcomes in BPD remains unclear. Literature regarding these therapies mostly addresses evolving BPD. There appears to be heterogeneity in treatment responses, and may be related to varying modes of administration. Further research is needed to evaluate inhaled therapies in infants with severe BPD. Such investigations should focus on appropriate definitions of disease and subject selection, timing of therapies, and new drugs, devices and delivery methods as compared to traditional methods across all modalities of respiratory support, in addition to the assessment of long-term outcomes of initial responders.
Collapse
Affiliation(s)
- Brian J. Clouse
- Center for Perinatal Research, The Research Institute at Nationwide Children’s Hospital, Columbus, Ohio, United States of America
- * E-mail:
| | - Sudarshan R. Jadcherla
- Center for Perinatal Research, The Research Institute at Nationwide Children’s Hospital, Columbus, Ohio, United States of America
- Division of Neonatology, Department of Pediatrics, Nationwide Children’s Hospital, Columbus, Ohio, United States of America
- The Ohio State University College of Medicine, Columbus, Ohio, United States of America
| | - Jonathan L. Slaughter
- Center for Perinatal Research, The Research Institute at Nationwide Children’s Hospital, Columbus, Ohio, United States of America
- Division of Neonatology, Department of Pediatrics, Nationwide Children’s Hospital, Columbus, Ohio, United States of America
- The Ohio State University College of Medicine, Columbus, Ohio, United States of America
| |
Collapse
|
17
|
Amirav I, Halamish A, Gorenberg M, Omar H, Newhouse MT. More Realistic Face Model Surface Improves Relevance of Pediatric In-Vitro Aerosol Studies. PLoS One 2015; 10:e0128538. [PMID: 26090661 PMCID: PMC4474798 DOI: 10.1371/journal.pone.0128538] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Accepted: 04/28/2015] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Various hard face models are commonly used to evaluate the efficiency of aerosol face masks. Softer more realistic "face" surface materials, like skin, deform upon mask application and should provide more relevant in-vitro tests. Studies that simultaneously take into consideration many of the factors characteristic of the in vivo face are lacking. These include airways, various application forces, comparison of various devices, comparison with a hard-surface model and use of a more representative model face based on large numbers of actual faces. AIM To compare mask to "face" seal and aerosol delivery of two pediatric masks using a soft vs. a hard, appropriately representative, pediatric face model under various applied forces. METHODS Two identical face models and upper airways replicas were constructed, the only difference being the suppleness and compressibility of the surface layer of the "face." Integrity of the seal and aerosol delivery of two different masks [AeroChamber (AC) and SootherMask (SM)] were compared using a breath simulator, filter collection and realistic applied forces. RESULTS The soft "face" significantly increased the delivery efficiency and the sealing characteristics of both masks. Aerosol delivery with the soft "face" was significantly greater for the SM compared to the AC (p< 0.01). No statistically significant difference between the two masks was observed with the hard "face." CONCLUSIONS The material and pliability of the model "face" surface has a significant influence on both the seal and delivery efficiency of face masks. This finding should be taken into account during in-vitro aerosol studies.
Collapse
Affiliation(s)
- Israel Amirav
- Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada
- Ziv Medical Center, Safed, Israel
- * E-mail:
| | | | | | - Hamza Omar
- Nuclear Medicine Department, Ziv Medical Center, Safed, Israel
| | - Michael T. Newhouse
- Firestone Institute for Respiratory Health, St. Joseph’s Hospital, McMaster University, Hamilton, Ontario, Canada
| |
Collapse
|
18
|
Amirav I, Newhouse MT, Luder A, Halamish A, Omar H, Gorenberg M. Feasibility of aerosol drug delivery to sleeping infants: a prospective observational study. BMJ Open 2014; 4:e004124. [PMID: 24670428 PMCID: PMC3975762 DOI: 10.1136/bmjopen-2013-004124] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVES Delivery of inhaled medications to infants is usually very demanding and is often associated with crying and mask rejection. It has been suggested that aerosol administration during sleep may be an attractive alternative. Previous studies in sleeping children were disappointing as most of the children awoke and rejected the treatment. The SootherMask (SM) is a new, gentle and innovative approach for delivering inhaled medication to infants and toddlers. The present pilot study describes the feasibility of administering inhaled medications during sleep using the SM. DESIGN Prospective observational study. SETTING Out patients. PARTICIPANTS 13 sleeping infants with recurrent wheezing who regularly used pacifiers and were <12 months old. INTERVENTION Participants inhaled technetium99mDTPA-labelled normal saline aerosol delivered via a Respimat Soft Mist Inhaler (SMI) (Boehringer-Ingelheim, Germany) and SM + InspiraChamber (IC; InspiRx Inc, New Jersey, USA). OUTCOMES The two major outcomes were the acceptability of the treatment and the lung deposition (per cent of emitted dose). RESULTS All infants who fulfilled the inclusion criteria successfully received the SM treatment during sleep without difficulty. Mean lung deposition (±SD) averaged 1.6±0.5% in the right lung. CONCLUSIONS This study demonstrated that the combination of Respimat, IC and SM was able to administer aerosol therapy to all the sleeping infants who were regular pacifier users with good lung deposition. Administration of aerosols during sleep is advantageous since all the sleeping children accepted the mask and ensuing aerosol therapy under these conditions, in contrast to previous studies in which there was frequent mask rejection using currently available devices. CLINICAL TRIAL REGISTRY NCT01120938.
Collapse
Affiliation(s)
- Israel Amirav
- Pediatric Department,Ziv Medical Center, Faculty of Medicine, Bar-Ilan University, Safed, Israel
- Pediatric Department, University of Alberta, Edmonton, Canada
| | | | - Anthony Luder
- Pediatric Department,Ziv Medical Center, Faculty of Medicine, Bar-Ilan University, Safed, Israel
| | - Asaf Halamish
- Nuclear Medicine Department, Ziv Medical Center, Safed, Israel
| | - Hamza Omar
- Firestone Institute for Respiratory Health, St Joseph's Hospital, McMaster University, Hamilton, Ontario, Canada
| | - Miguel Gorenberg
- Firestone Institute for Respiratory Health, St Joseph's Hospital, McMaster University, Hamilton, Ontario, Canada
| |
Collapse
|