1
|
İnce Kuka G, Gürsoy H. Root surface roughness evaluation following application of different periodontal instruments and Er:YAG laser: A profilometry and SEM study. Lasers Med Sci 2024; 39:98. [PMID: 38583109 PMCID: PMC10999381 DOI: 10.1007/s10103-024-04025-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 02/13/2024] [Indexed: 04/08/2024]
Abstract
AIM The aim of the present study was to evaluate the efficacy of 30°-angled Er:YAG laser tip and different periodontal instruments on root surface roughness and morphology in vitro. METHODS Eighteen bovine teeth root without carious lesion were decoronated from the cementoenamel junction and seperated longitidunally. A total of 36 obtained blocks were mounted in resin blocks and polished with silicon carbide papers under water irrigation. These blocks were randomly assigned into 3 treatment groups. In Group 1, 30°-angled Er:YAG laser (2.94 μm) tip was applied onto the blocks with a 20 Hz, 120 mJ energy output under water irrigation for 20 s. In Groups 2 and 3, the same treatment was applied to the blocks with new generation ultrasonic tip and conventional curette apico-coronally for 20 s with a sweeping motion. Surface roughness and morphology were evaluated before and after instrumentation with a profilometer and SEM, respectively. RESULTS After instrumentation, profilometric analysis revealed significantly higher roughness values compared to baseline in all treatment groups(p < 0.05). Laser group revealed the roughest surface morphology followed by conventional curette and new generation ultrasonic tip treatment groups (p < 0.05). In SEM analysis, irregular surfaces and crater defects were seen more frequently in the laser group. CONCLUSION Results of the study showed that the use of new generation ultrasonic tip was associated with smoother surface morphology compared to 30°-angled Er-YAG laser tip and conventional curette. Further in vitro and in vivo studies with an increased sample size are necessary to support the present study findings.
Collapse
Affiliation(s)
- Gizem İnce Kuka
- Department of Periodontology, Hamidiye Dental Faculty, University of Health Sciences, Istanbul, Turkey.
| | - Hare Gürsoy
- Department of Periodontology, Hamidiye Dental Faculty, University of Health Sciences, Istanbul, Turkey
| |
Collapse
|
2
|
Ince Kuka G, Kuru B, Gursoy H. In Vitro Evaluation of the Different Supragingival Prophylaxis Tips on Enamel Surfaces. Photobiomodul Photomed Laser Surg 2023; 41:212-217. [PMID: 37083509 DOI: 10.1089/photob.2022.0137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/22/2023] Open
Abstract
Objective: Periodontal instrumentation during supragingival prophylaxis may increase enamel surface roughness, which may lead to increased dental biofilm accumulation and demineralization of the enamel. The aim of this study was to evaluate the changes of the enamel surface profilometrically after the application of different scaler tips used for the professional supragingival prophylaxis. Materials and methods: Forty-eight enamel block samples obtained from extracted human maxillary premolar teeth were prepared and randomly assigned to four different treatment groups. Each treatment group was instrumented by the same clinician with different tools as Group 1: Er:YAG laser chisel tip, Group 2: scaler, Group 3: new generation universal curette; and Group 4: ultrasonic device. Sample surfaces were evaluated with a profilometer before and after instrumentations and after the polishing process. Results: Baseline roughness of the prepared enamel samples was similar between the groups. After instrumentation and polishing, the Er:YAG laser chisel tip revealed the most irregular surface morphology, whereas the new generation curette induced the smoothest surface. Conclusions: New generation universal curette is a promising tool, which can be used safely for supragingival calculus removal without the need for polishing on enamel surfaces.
Collapse
Affiliation(s)
- Gizem Ince Kuka
- Department of Periodontology, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Bahar Kuru
- Department of Periodontology, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Hare Gursoy
- Department of Periodontology, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| |
Collapse
|
3
|
Lang KN, Sculean A, Eick S, Stähli A. A novel in vitro periodontal pocket model to evaluate the effect of root surface instrumentation on biofilm-epithelial cell interactions. Clin Oral Investig 2022; 26:4021-4029. [PMID: 35048191 PMCID: PMC9072513 DOI: 10.1007/s00784-022-04371-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 01/02/2022] [Indexed: 12/13/2022]
Abstract
Abstract
Objective
To develop a novel in vitro periodontal pocket model for evaluating the effect of two different root surface instrumentation modalities on biofilm-epithelial cell interactions.
Materials and methods
An artificial periodontal pocket model was created using an impression material. Dentin discs were prepared and incubated for 3.5 days with a biofilm consisting of 12 bacterial strains. Then, the discs were inserted into the pocket model and instrumented for 10 s or 10 strokes either with ultrasonics (US) or hand instruments (HI). Subsequently, a glass slide coated with epithelial cells was placed in close vicinity to the discs. After incubation of the pocket model in a 5% CO2 atmosphere for 6 h, residual bacteria of the biofilm as well as bacteria adhering to or invaded into epithelial cells were determined using colony-forming unit (cfu) counts and real-time PCR. Further, as a parameter of the pro-inflammatory cell response, interleukin (IL)-8 expression was determined by ELISA.
Results
Compared to untreated control, HI reduced the cfu counts by 0.63 log10 (not significant) and US by 1.78 log10 (p = 0.005) with a significant difference between the treatment modalities favoring US (p = 0.048). By trend, lower detection levels of Tannerella forsythia were detected in the US group compared to HI. Concerning the interaction with epithelial cells, half of the control and the HI samples showed epithelial cells with attaching or invading bacteria, while US displayed bacteria only in two out of eight samples. In addition, US resulted in significantly lower IL-8 secretion by epithelial cells compared to the untreated control. Between HI and controls, no statistically significant difference in IL-8 secretion was found.
Conclusion
This newly developed in vitro model revealed in terms of biofilm-epithelial cell interaction after root surface instrumentation that compared to hand curettes, ultrasonic instrumentation appeared to be more effective in removing bacterial biofilm and in decreasing the inflammatory response of epithelium to biofilm.
Clinical relevance
Ultrasonic instrumentation might be more advantageous to reduce cellular inflammatory response than hand instruments.
Collapse
Affiliation(s)
- Kiri N. Lang
- Department of Periodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010 Bern, Switzerland
| | - Anton Sculean
- Department of Periodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010 Bern, Switzerland
| | - Sigrun Eick
- Department of Periodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010 Bern, Switzerland
| | - Alexandra Stähli
- Department of Periodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010 Bern, Switzerland
| |
Collapse
|
4
|
Yildirim TT, Oztekin F, Keklik E, Tozum MD. Surface roughness of enamel and root surface after scaling, root planning and polishing procedures: An in-vitro study. J Oral Biol Craniofac Res 2021; 11:287-290. [PMID: 33948429 DOI: 10.1016/j.jobcr.2021.02.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 02/04/2021] [Accepted: 02/22/2021] [Indexed: 11/30/2022] Open
Abstract
Objectives The aim of this study was to evaluate enamel and root surface roughness on exracted human teeth by using different tecniques (ultrasonic scaler, hand instruments, polishing paste, pumice and air powder system). Materials and methods A total of 200 samples were divided into two groups (enamel and root) randomly with 100 samples for each enamel and root groups. The groups were divided into 5 subgroups: Group I: ultrasonic scaler, group II: hand instruments, group III: polishing paste, group IV: pumice, group V: air-powder. Surface roughness (Ra) was assessed with Mitutoyo SJ-410 device. The one-way analysis of variance (ANOVA) test along with the Tukey test was used for statistical analysis. P values less than 0.05 were considered statistically significant. Results The use of ultrasonic scalers caused the highest roughness increase on the enamel surface (0.935 ± 0.010), whereas the use of pumice was the least (0.896 ± 0.018) (p < 0.05). There was a significant difference between ultrasonic scalers and all the groups (hand instruments, polishing paste, pumice and air powder system) on enamel surface (p < 0.05). Maximum surface roughness increase was observed in the ultrasonic scalers on root surface. There was a significant difference between ultrasonic scalers and polishing paste, pumice and air powder on root surface, respectively (p < 0.05). Conclusion The use of ultrasonic scalers cause more rough enamel and root surfaces than hand instrumentation and polishing tecniques. Clinical relevance Uneven surfaces adversely affect the intended periodontal healing by creating a retention area of microbial dental plaque.
Collapse
Affiliation(s)
- Tuba Talo Yildirim
- Department of Periodontology, Faculty of Dentistry, Firat University, Elazig, Turkey
| | - Faruk Oztekin
- Department of Endodontics, Faculty of Dentistry, Firat University, Elazig, Turkey
| | - Esra Keklik
- Department of Periodontology, Faculty of Dentistry, Firat University, Elazig, Turkey
| | - Melek Didem Tozum
- Pre-Doctoral Clinics, College of Dentistry, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
5
|
Gürsoy H, Tunar OL, Ince Kuka G, Ozkan Karaca E, Kocabaş H, Kuru BE. Profilometric Analysis of Periodontally Diseased Root Surfaces After Application of Different Instrumentation Tools: An In Vitro Study. PHOTOBIOMODULATION PHOTOMEDICINE AND LASER SURGERY 2020; 38:181-185. [PMID: 31944884 DOI: 10.1089/photob.2019.4726] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Objective: The topography of the root surface plays an important role in plaque accumulation, cell adhesion, and periodontal healing. The aim of this study is to profilometrically evaluate the root surface changes following the instrumentation using different tools. Methods: Forty dentin blocks of buccal and lingual root surfaces were obtained from 20 single-rooted periodontally diseased hopeless teeth and randomly divided into 4 groups. Each group was subjected to different root instrumentation tools such as stainless steel (SS) Gracey curette (Group 1); titanium nitride (TIN) Gracey curette (Group 2); ultrasonic piezoelectric device with a special tip designed for root surfaces (H3) (Group 3); and Er:YAG laser (Er:YAG tip) chisel (Group 4). A calibrated clinician instrumented all surfaces in each group. The root surfaces were profilometrically evaluated before and after instrumentations. Results: There were no statistical differences between the initial roughness levels of the groups. TIN curettes revealed the most prominent effect on smoothing the surface, whereas the Er:YAG tip showed the highest roughness in comparison with the other root surface instrumentation tools. Conclusions: Considering the importance of root surface roughness after treatment for the success of periodontal therapy, the TIN curette was the most periodontally appealing tool followed by H3, SS curette, and Er:YAG tip.
Collapse
Affiliation(s)
- Hare Gürsoy
- Department of Periodontology, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Ogul Leman Tunar
- Department of Periodontology, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Gizem Ince Kuka
- Department of Periodontology, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Ebru Ozkan Karaca
- Department of Periodontology, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Hazel Kocabaş
- Department of Periodontology, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Bahar Eren Kuru
- Department of Periodontology, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey
| |
Collapse
|
6
|
Arora S, Lamba AK, Faraz F, Tandon S, Ahad A. Evaluation of the Effects of Er,Cr:YSGG Laser, Ultrasonic Scaler and Curette on Root Surface Profile Using Surface Analyser and Scanning Electron Microscope: An In Vitro Study. J Lasers Med Sci 2017; 7:243-249. [PMID: 28491260 DOI: 10.15171/jlms.2016.43] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: The periodontal therapy is primarily targeted at removal of dental plaque and plaque retentive factors. Although the thorough removal of adherent plaque, calculus and infected root cementum is desirable, it is not always achieved by conventional modalities. To accomplish more efficient results several alternative devices have been used. Lasers are one of the most promising modalities for nonsurgical periodontal treatment as they can achieve excellent tissue ablation with strong bactericidal and detoxification effects. Methods: Thirty freshly extracted premolars were selected and decoronated. The mesial surface of each root was divided vertically into four approximately equal parts. These were distributed into four group based on the root surface treatment. Part A (n = 30) was taken as control and no instrumentation was performed. Part B (n = 30) was irradiated by Erbium, Chromium doped Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser. Part C (n = 30) was treated by piezoelectric ultrasonic scaler. Part D (n = 30) was treated by Gracey curette. The surface roughness was quantitatively analyzed by profilometer using roughness average (Ra) value, while presence of smear layer, cracks, craters and melting of surface were analyzed using scanning electron microscope (SEM). The means across the groups were statistically compared with control using Dunnett test. Results: Among the test groups, Er,Cr:YSGG laser group showed maximum surface roughness (mean Ra value of 4.14 μm) as compared to ultrasonic scaler (1.727 μm) and curette group (1.22 μm). However, surface with smear layer were found to be maximum (50%) in curette treated samples and minimum (20%) in laser treated ones. Maximum cracks (83.34%) were produced by ultrasonic scaler, and minimum (43.33%) by curettes. Crater formation was maximum (50%) in laser treated samples and minimum (3.33%) in curette treated ones. 63.33% samples treated by laser demonstrated melting of root surface, followed by ultrasonic scaler and curettes. Conclusion: Er,Cr:YSGG laser produced maximum microstructural changes on root surface that can influence the attachment of soft periodontal tissues as well as plaque and calculus deposition. In vivo studies are needed to validate these results and to evaluate their clinical effects.
Collapse
Affiliation(s)
- Shipra Arora
- Department of Public Health Dentistry, Maulana Azad Institute of Dental Sciences, New Delhi, India
| | - Arundeep Kaur Lamba
- Department of Periodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India
| | - Farrukh Faraz
- Department of Periodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India
| | - Shruti Tandon
- Department of Periodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India
| | - Abdul Ahad
- Department of Periodontics, Dr. Ziauddin Ahmad Dental College, Aligarh Muslim University, Aligarh, India
| |
Collapse
|
7
|
Amid R, Gholami GA, Mojahedi M, Aghalou M, Gholami M, Mirakhori M. Effects of Root Debridement With Hand Curettes and Er:YAG Laser on Chemical Properties and Ultrastructure of Periodontally-Diseased Root Surfaces Using Spectroscopy and Scanning Electron Microscopy. J Lasers Med Sci 2017; 8:66-71. [PMID: 28652898 DOI: 10.15171/jlms.2017.12] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Introduction: The efficacy of erbium-doped yttrium aluminum garnet (Er:YAG) laser for root debridement in comparison with curettes has been the subject of many recent investigations. Considering the possibility of chemical and ultra-structural changes in root surfaces following laser irradiation, this study sought to assess the effects of scaling and root planing (SRP) with curettes and Er:YAG laser on chemical properties and ultrastructure of root surfaces using spectroscopy and scanning electron microscopy (SEM). Methods: In this in vitro experimental study, extracted sound human single-rooted teeth (n = 50) were randomly scaled using manual curettes alone or in conjunction with Er:YAG laser at 100 and 150 mJ/pulse output energies. The weight percentages of carbon, oxygen, phosphorous and calcium remaining on the root surfaces were calculated using spectroscopy and the surface morphology of specimens was assessed under SEM. Data were analyzed using one-way analysis of variance (ANOVA). Results: No significant differences (P > 0.05) were noted in the mean carbon, oxygen, phosphorous and calcium weight percentages on root surfaces following SRP using manual curettes with and without laser irradiation at both output energies. Laser irradiation after SRP with curettes yielded rougher surfaces compared to the use of curettes alone. Conclusion: Although laser irradiation yielded rougher surfaces, root surfaces were not significantly different in terms of chemical composition following SRP using manual curettes with and without Er:YAG laser irradiation. Er:YAG laser can be safely used as an adjunct to curettes for SRP.
Collapse
Affiliation(s)
- Reza Amid
- Deptartment of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Dental Research Center, Research Institute of Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Gholam Ali Gholami
- Deptartment of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Masoud Mojahedi
- Deptartmen of Laser, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Maryam Aghalou
- Deptartment of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | | | - Mahdieh Mirakhori
- Dental Research Center, Research Institute of Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
8
|
Hägi TT, Klemensberger S, Bereiter R, Nietzsche S, Cosgarea R, Flury S, Lussi A, Sculean A, Eick S. A Biofilm Pocket Model to Evaluate Different Non-Surgical Periodontal Treatment Modalities in Terms of Biofilm Removal and Reformation, Surface Alterations and Attachment of Periodontal Ligament Fibroblasts. PLoS One 2015; 10:e0131056. [PMID: 26121365 PMCID: PMC4486723 DOI: 10.1371/journal.pone.0131056] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2015] [Accepted: 05/28/2015] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND AND AIM There is a lack of suitable in vitro models to evaluate various treatment modalities intending to remove subgingival bacterial biofilm. Consequently, the aims of this in vitro-study were: a) to establish a pocket model enabling mechanical removal of biofilm and b) to evaluate repeated non-surgical periodontal treatment with respect to biofilm removal and reformation, surface alterations, tooth hard-substance-loss, and attachment of periodontal ligament (PDL) fibroblasts. MATERIAL AND METHODS Standardized human dentin specimens were colonized by multi-species biofilms for 3.5 days and subsequently placed into artificially created pockets. Non-surgical periodontal treatment was performed as follows: a) hand-instrumentation with curettes (CUR), b) ultrasonication (US), c) subgingival air-polishing using erythritol (EAP) and d) subgingival air-polishing using erythritol combined with chlorhexidine digluconate (EAP-CHX). The reduction and recolonization of bacterial counts, surface roughness (Ra and Rz), the caused tooth substance-loss (thickness) as well as the attachment of PDL fibroblasts were evaluated and statistically analyzed by means of ANOVA with Post-Hoc LSD. RESULTS After 5 treatments, bacterial reduction in biofilms was highest when applying EAP-CHX (4 log10). The lowest reduction was found after CUR (2 log10). Additionally, substance-loss was the highest when using CUR (128±40 µm) in comparison with US (14±12 µm), EAP (6±7 µm) and EAP-CHX (11±10) µm). Surface was roughened when using CUR and US. Surfaces exposed to US and to EAP attracted the highest numbers of PDL fibroblasts. CONCLUSION The established biofilm model simulating a periodontal pocket combined with interchangeable placements of test specimens with multi-species biofilms enables the evaluation of different non-surgical treatment modalities on biofilm removal and surface alterations. Compared to hand instrumentation the application of ultrasonication and of air-polishing with erythritol prevents from substance-loss and results in a smooth surface with nearly no residual biofilm that promotes the reattachment of PDL fibroblasts.
Collapse
Affiliation(s)
- Tobias T. Hägi
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Sabrina Klemensberger
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Riccarda Bereiter
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Sandor Nietzsche
- Centre of Electron Microscopy, University Hospital of Jena, Jena, Germany
| | - Raluca Cosgarea
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthetic Dentistry, University of Cluj-Napoca, Cluj-Napoca, Romania
- Department of Periodontology, Philips University, Marburg, Germany
| | - Simon Flury
- Department of Preventive, Restorative and Pediatric Dentistry, University of Bern, Bern, Switzerland
| | - Adrian Lussi
- Department of Preventive, Restorative and Pediatric Dentistry, University of Bern, Bern, Switzerland
| | - Anton Sculean
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Sigrun Eick
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- * E-mail:
| |
Collapse
|
9
|
de Oliveira GJPL, Cominotte MA, Beraldo TPP, Sampaio JEC, Marcantonio RAC. A microscopic analysis of the effects of root surface scaling with different power parameters of Er,Cr:YSGG laser. Microsc Res Tech 2015; 78:529-35. [PMID: 25951453 DOI: 10.1002/jemt.22505] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2014] [Revised: 02/19/2015] [Accepted: 03/22/2015] [Indexed: 11/12/2022]
Abstract
The aim of this study was to evaluate the effects of different power parameters of an Erbium, Cromium: Yttrium, Scandium, Gallium, Garnet laser (Er,Cr:YSGG laser) on the morphology, attachment of blood components (ABC), roughness, and wear on irradiated root surfaces. Sixty-five incisive bovine teeth were used in this study, 35 of which were used for the analysis of root surface morphology and ABC. The remaining 30 teeth were used for roughness and root wear analysis. The samples were randomly allocated into seven groups: G1: Er,Cr:YSGG laser, 0.5 W; G2: Er,Cr:YSGG laser, 1.0 W; G3: Er,Cr:YSGG laser, 1.5 W; G4: Er,Cr:YSGG laser, 2.0 W; G5: Er,Cr:YSGG laser, 2.5 W; G6: Er,Cr:YSGG laser, 3.0 W; G7: scaling and root planning (SRP) with manual curettes. The root surfaces irradiated by Er,Cr:YSGG at 1.0 W and scaling with manual curettes presented the highest degrees of ABC. The samples irradiated by the Er,Cr:YSGG laser were rougher than the samples treated by the manual curette, and increasing the laser power parameters caused more root wear and greater roughness on the root surface. The Er,Cr:YSGG laser is safe to use for periodontal treatment, but it is not appropriate to use irradiation greater than 1.0 W for this purpose.
Collapse
|
10
|
Oliveira G, Macedo PD, Tsurumaki JN, Sampaio JE, Marcantonio R. The effect of the angle of instrumentation of the Piezoelectric Ultrasonic Scaler on root surfaces. Int J Dent Hyg 2015; 14:184-90. [PMID: 25690687 DOI: 10.1111/idh.12134] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2015] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To evaluate the influence of variations in the working angle of the piezoelectric ultrasonic scaler (PUS) on root surfaces. MATERIAL AND METHODS Fifty-five uniradicular bovine teeth were used, of which 25 teeth were used for the analysis of the roughness and root wear, while the remaining 30 teeth were used for the analysis of morphology (MRS) and the attachment of blood components (ABC). The teeth were randomly divided into five groups according to the type of treatment (G1-G5: piezoelectric ultrasonic scaler; G6: manual curette) and to the PUS working angle applied (G1: 0°; G2: 30°; G3: 45°; G4: 60°; G5: 90°). For statistical analysis, the data describing the MRS and ABC were analysed by the Kruskal-Wallis and Dunn's tests, and the data describing the roughness and tooth wear were analysed by anova and Tukey's tests at the significance level of 5%. RESULTS Manual curette (MC) promoted a smoother root surface than the application of the PUS. The PUS used at the angles of 30° and 45° resulted in a high level of ABC that was comparable to that obtained by MC. Additionally, the group in which the PUS was applied at an angle of 45° exhibited less tooth wear than the other groups. CONCLUSIONS Changes in the working angle of the PUS influenced the characteristics of root surfaces after instrumentation.
Collapse
Affiliation(s)
- Gjpl Oliveira
- Foar-UNESP, School of Dentistry of Araraquara, São Paulo State University, Araraquara, Brazil
| | - P D Macedo
- Foar-UNESP, School of Dentistry of Araraquara, São Paulo State University, Araraquara, Brazil
| | - J N Tsurumaki
- Foar-UNESP, School of Dentistry of Araraquara, São Paulo State University, Araraquara, Brazil
| | - J E Sampaio
- Foar-UNESP, School of Dentistry of Araraquara, São Paulo State University, Araraquara, Brazil
| | - Rac Marcantonio
- Foar-UNESP, School of Dentistry of Araraquara, São Paulo State University, Araraquara, Brazil
| |
Collapse
|
11
|
Miranda PV, Rodrigues JA, Blay A, Shibli JA, Cassoni A. Surface alterations of zirconia and titanium substrates after Er,Cr:YSGG irradiation. Lasers Med Sci 2014; 30:43-8. [DOI: 10.1007/s10103-013-1516-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2013] [Accepted: 12/15/2013] [Indexed: 11/25/2022]
|
12
|
Amid R, Kadkhodazadeh M, Fekrazad R, Hajizadeh F, Ghafoori A. Comparison of the effect of hand instruments, an ultrasonic scaler, and an erbium-doped yttrium aluminium garnet laser on root surface roughness of teeth with periodontitis: a profilometer study. J Periodontal Implant Sci 2013; 43:101-5. [PMID: 23678394 PMCID: PMC3651935 DOI: 10.5051/jpis.2013.43.2.101] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Accepted: 03/22/2013] [Indexed: 12/14/2022] Open
Abstract
PURPOSE The present study aimed to measure root surface roughness in teeth with periodontitis by a profilometer following root planning with ultrasonic and hand instruments with and without erbium-doped yttrium aluminium garnet (Er:YAG) laser irradiation. METHODS Sixty single-rooted maxillary and mandibular teeth, extracted because of periodontal disease, were collected. The crowns and apices of the roots were cut off using a diamond bur and water coolant. The specimens were mounted in an acrylic resin block such that a plain root surface was accessible. After primary evaluation and setting a baseline, the samples were divided into 4 groups. In group 1, the samples were root planned using a manual curette. The group 2 samples were prepared with an ultrasonic scaler. In group 3, after scaling with hand instrumentation, the roots were treated with a Smart 1240D plus Er:YAG laser and in group 4, the roots were prepared with ultrasonic scaler and subsequently treated with an Er:YAG laser. Root surface roughness was then measured by a profilometer (MahrSurf M300+RD18C system) under controlled laboratory conditions at a temperature of 25℃ and 41% humidity. The data were analyzed statistically using analysis of variance and a t-test (P<0.05). RESULTS Significant differences were detected in terms of surface roughness and surface distortion before and after treatment. The average reduction of the surface roughness after treatment in groups 1, 2, 3, and 4 was 1.89, 1.88, 1.40, and 1.52, respectively. These findings revealed no significant differences among the four groups. CONCLUSIONS An Er:YAG laser as an adjunct to traditional scaling and root planning reduces root surface roughness. However, the surface ultrastructure is more irregular than when using conventional methods.
Collapse
Affiliation(s)
- Reza Amid
- Department of Periodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | | | | | | | | |
Collapse
|
13
|
In vitro evaluation of surface roughness, adhesion of periodontal ligament fibroblasts, and Streptococcus gordonii following root instrumentation with Gracey curettes and subsequent polishing with diamond-coated curettes. Clin Oral Investig 2012; 17:397-404. [DOI: 10.1007/s00784-012-0719-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2011] [Accepted: 03/14/2012] [Indexed: 10/28/2022]
|
14
|
de Oliveira GJPL, Pavone C, Sampaio JEC, Marcantonio RAC. Influence of the angle of irradiation of the Er,Cr:YSGG laser on the morphology, attachment of blood components, roughness, and root wear: in vitro study. Lasers Surg Med 2011; 42:683-91. [PMID: 20976808 DOI: 10.1002/lsm.20973] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND AND OBJECTIVES To evaluate the influence of the working tip angulation of the Er,Cr:YSGG laser on the morphology, attachment of blood components, roughness, and wear on irradiated root surfaces compared to scaling and root planing (SRP). STUDY DESIGN/MATERIALS AND METHODS The present study used 45 teeth, of which 25 were used for the analysis of the morphology and the attachment of blood components and 20 were used for the analysis of the roughness and of the root wear. The teeth were randomly divided into five groups according to the treatment applied: (G1) Laser Er,Cr:YSGG-30°; (G2) Laser Er,Cr:YSGG-45°; (G3) Laser Er,Cr:YSGG-60°; (G4) Laser Er,Cr:YSGG-90°; and (G5) SRP. RESULTS The root surfaces irradiated with the Er,Cr:YSGG laser working angulation tip of 45° and 60°, and the samples scaled with manual instruments presented greater attachment of blood components than the group where the Er,Cr:YSGG laser irradiated at working tip angulation of 30° and 90° (P<0.05). The samples irradiated with the Er,Cr:YSGG laser were rougher than the samples scaled with manual instruments (P<0.05). The group that was irradiated with the Er,Cr:YSGG laser at an angle of 30° presented the least wear in comparison to all the other treatments (P<0.01). CONCLUSIONS The irradiated root surfaces proved to be rougher than those scaled with manual instruments; however, irradiation at working tip angulations of 45° and 60° produced results of attachment of blood components and root wear comparable with those obtained with manual instrumentation.
Collapse
|
15
|
Tsurumaki JDN, Souto BHM, Oliveira GJPLD, Sampaio JEC, Marcantonio Júnior E, Marcantonio RAC. Effect of instrumentation using curettes, piezoelectric ultrasonic scaler and Er,Cr:YSGG laser on the morphology and adhesion of blood components on root surfaces: a SEM study. Braz Dent J 2011; 22:185-92. [DOI: 10.1590/s0103-64402011000300002] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
This study used scanning electron microscopy (SEM) to evaluate the morphology and adhesion of blood components on root surfaces instrumented by curettes, piezoelectric ultrasonic scaler and Er,Cr:YSGG laser. One hundred samples from 25 teeth were divided into 5 groups: 1) Curettes; 2) Piezoelectric ultrasonic scaler; 3) Curettes plus piezoelectric ultrasonic scaler; 4) Er,Cr:YSGG laser; 5) Curettes plus Er,Cr:YSGG laser. Ten samples from each group were used for analysis of root morphology and the other 10 were used for analysis of adhesion of blood components on root surface. The results were analyzed statistically by the Kruskall-Wallis and Mann-Whitney tests with a significance level of 5%. The group treated with curettes showed smoother surfaces when compared to the groups were instrumented with piezoelectric ultrasonic scaler and the Er,Cr:YSGG laser. The surfaces instrumented with piezoelectric ultrasonic scaler and Er,Cr:YSGG laser, alone or in combination with hand scaling and root planing, did not differ significantly (p>0.05) among themselves. No statistically significant differences (p>0.05) among groups were found as to the adhesion of blood components on root surface. Ultrasonic instrumentation and Er,Cr:YSGG irradiation produced rougher root surfaces than the use of curettes, but there were no differences among treatments with respect to the adhesion of blood components.
Collapse
|
16
|
Jepsen S, Deschner J, Braun A, Schwarz F, Eberhard J. Calculus removal and the prevention of its formation. Periodontol 2000 2010; 55:167-88. [DOI: 10.1111/j.1600-0757.2010.00382.x] [Citation(s) in RCA: 84] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
17
|
Oliveira GJPL, Sampaio JEC, Marcantonio RAC. Effects of Er,Cr:YSGG Laser Irradiation on Root Surfaces for Adhesion of Blood Components and Morphology. Photomed Laser Surg 2010; 28:751-6. [DOI: 10.1089/pho.2009.2681] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
| | - José Eduardo Cézar Sampaio
- UNESP, São Paulo State University, Department of Periodontology, School of Dentistry, Araraquara, SP, Brazil
| | | |
Collapse
|
18
|
Ota-Tsuzuki C, Martins FL, Giorgetti APO, de Freitas PM, Duarte PM. In vitro adhesion of Streptococcus sanguinis to dentine root surface after treatment with Er:YAG laser, ultrasonic system, or manual curette. Photomed Laser Surg 2010; 27:735-41. [PMID: 19712018 DOI: 10.1089/pho.2008.2324] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE The purpose of this in vitro study was to evaluate the dentine root surface roughness and the adherence of Streptococcus sanguinis (ATCC 10556) after treatment with an ultrasonic system, Er:YAG laser, or manual curette. BACKGROUND DATA Bacterial adhesion and formation of dental biofilm after scaling and root planing may be a challenge to the long-term stability of periodontal therapy. MATERIALS AND METHODS Forty flattened bovine roots were randomly assigned to one of the following groups: ultrasonic system (n = 10); Er:YAG laser (n = 10); manual curette (n = 10); or control untreated roots (n = 10). The mean surface roughness (Ra, microm) of the specimens before and after exposure to each treatment was determined using a surface profilometer. In addition, S. sanguinis was grown on the treated and untreated specimens and the amounts of retained bacteria on the surfaces were measured by culture method. RESULTS All treatments increased the Ra; however, the roughest surface was produced by the curettes. In addition, the specimens treated with curettes showed the highest S. sanguinis adhesion. There was a significant positive correlation between roughness values and bacterial cells counts. CONCLUSION S. sanguinis adhesion was the highest on the curette-treated dentine root surfaces, which also presented the greatest surface roughness.
Collapse
Affiliation(s)
- Claudia Ota-Tsuzuki
- Dental Research Division, Department of Periodontics, Guarulhos University, São Paulo, Brazil.
| | | | | | | | | |
Collapse
|