1
|
Guan A, He T, Huang X, Xia W, Shao Y. Fat Liquefaction and Lipo Particles in a CIED Pocket During Generator Change-Not an Infection: A Rare Case Report. Int Med Case Rep J 2025; 18:53-58. [PMID: 39811102 PMCID: PMC11730515 DOI: 10.2147/imcrj.s505053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2024] [Accepted: 01/07/2025] [Indexed: 01/16/2025] Open
Abstract
A case of fat liquefaction and fat particles in the pacemaker pocket observed in a female patient 12 years after implantation. The patient had no symptoms and no signs of infection or other discomfort of the heart and pacemaker pocket. The biochemical analysis showed a slight increase in cardiac troponin T, 0.026 ng/mL (reference range, <0.016 ng/mL), a high increase in total cholesterol, 8.70 mmol/L (reference range, <5.18 mmol/L), and low density lipoprotein, 5.38 mmol/L (reference range, <3.37 mmol/L). Thick yellow liquid was seen to flow out of the pacemaker pocket when the pocket was opened, and many fat particles were found adhering to the wall of the pacemaker pocket during the pacemaker replacement procedure. Fat and fibrillar connective tissue with a few inflammatory cells, local tissue degeneration and necrosis were shown on immunohistochemical staining and no bacterial growth including anaerobic bacteria was observed. The aseptic necrosis of post-implantation complications is helpful for differential diagnosis in CIED complication. Moreover, the identification of fat liquefaction has important clinical significance for patient management and surgical decision-making.
Collapse
Affiliation(s)
- Aili Guan
- Department of Cardiology, Heart Center, Qingdao Municipal Hospital, Qingdao, Shandong, 266071, People’s Republic of China
| | - Tao He
- Department of Cardiology, Heart Center, Qingdao Municipal Hospital, Qingdao, Shandong, 266071, People’s Republic of China
| | - Xingang Huang
- Department of Pathology, Qingdao Municipal Hospital, Qingdao, Shandong, 266071, People’s Republic of China
| | - Wei Xia
- Department of Cardiology, Heart Center, Qingdao Municipal Hospital, Qingdao, Shandong, 266071, People’s Republic of China
| | - Yibing Shao
- Department of Cardiology, Heart Center, Qingdao Municipal Hospital, Qingdao, Shandong, 266071, People’s Republic of China
| |
Collapse
|
2
|
Jiménez-Candil J, Oterino A, Cruz Galbán A, Hernández J, Moríñigo JL, Sánchez García M, Sánchez PL. Outcomes of a 24/7 service for urgent permanent pacemaker implantation. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2024; 77:899-909. [PMID: 38521441 DOI: 10.1016/j.rec.2024.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 03/11/2024] [Indexed: 03/25/2024]
Abstract
INTRODUCTION AND OBJECTIVES Most of the complications associated with acute and symptomatic bradyarrhythmia (ASB) occur in the time from diagnosis to permanent pacemaker implantation (PPI). We aimed to evaluate the outcomes of an urgent 24/7 PPI service (PPI-24/7) for patients with ASB. METHODS A total of 664 patients undergoing first-time PPI for ASB were prospectively assessed during 2 periods of identical length (18 months): 341 patients who underwent the procedure during working hours only (PPI-WH), and 323 patients who underwent the procedure after the implementation of the PPI-24/7 service. The primary safety endpoint was established as the cumulative 180-day incidence of complications related to the index arrhythmia and device implant. The primary efficacy endpoint was determined as the average number of hospital stays per patient. RESULTS The PPI-24/7 period was associated with a significant shortening of the time from diagnosis to implantation (median [interquartile range]): 3hours [2-6] vs 16 [5-21]). The cumulative incidence of patients with complications at 180 days was lower in the PPI-24/7 period: 9% vs 17% (adjusted odds ratio, 0.5; P=.002), due to a significant reduction in preimplant complications: 2.5% vs 12% (P <.001). The average number of hospital stays was reduced by 2 per patient in the PPI-24/7 period (nonparametric P <.001). PPI-24/7 implants performed outside working hours (n=178) were safe, with a 180-day cumulative incidence in procedure-related complications of 3.9%. CONCLUSIONS Among patients with ASB, PPI-24/7 was associated with a significant reduction in patient morbidity and efficient hospital resource use.
Collapse
Affiliation(s)
- Javier Jiménez-Candil
- Servicio de Cardiología, Instituto de Investigación Biomédica de Salamanca (IBSAL), Hospital Universitario de Salamanca, Salamanca, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain; Departamento de Medicina, Universidad de Salamanca, Salamanca, Spain.
| | - Armando Oterino
- Servicio de Cardiología, Instituto de Investigación Biomédica de Salamanca (IBSAL), Hospital Universitario de Salamanca, Salamanca, Spain
| | - Alba Cruz Galbán
- Servicio de Cardiología, Instituto de Investigación Biomédica de Salamanca (IBSAL), Hospital Universitario de Salamanca, Salamanca, Spain
| | - Jesús Hernández
- Servicio de Cardiología, Instituto de Investigación Biomédica de Salamanca (IBSAL), Hospital Universitario de Salamanca, Salamanca, Spain
| | - José Luis Moríñigo
- Servicio de Cardiología, Instituto de Investigación Biomédica de Salamanca (IBSAL), Hospital Universitario de Salamanca, Salamanca, Spain; Departamento de Medicina, Universidad de Salamanca, Salamanca, Spain
| | - Manuel Sánchez García
- Servicio de Cardiología, Instituto de Investigación Biomédica de Salamanca (IBSAL), Hospital Universitario de Salamanca, Salamanca, Spain
| | - Pedro L Sánchez
- Servicio de Cardiología, Instituto de Investigación Biomédica de Salamanca (IBSAL), Hospital Universitario de Salamanca, Salamanca, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain; Departamento de Medicina, Universidad de Salamanca, Salamanca, Spain
| |
Collapse
|
3
|
Bengtsen KH, Falkentoft AC, Le MV, Haugan K, Philbert BT, Johansen JB, Torp-Pedersen C, Riahi S, Nielsen JC, Larroudé C, Petersen A, Larsen AR, Østergaard L, Fosbøl E, Bruun NE, Ruwald AC. Incidence of Staphylococcus aureus Bacteremia in Patients Following Implantation of Cardiac Implantable Electronic Devices: A Danish Nationwide Cohort Study. Open Forum Infect Dis 2024; 11:ofae515. [PMID: 39329108 PMCID: PMC11425531 DOI: 10.1093/ofid/ofae515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Accepted: 08/30/2024] [Indexed: 09/28/2024] Open
Abstract
Background Staphylococcus aureus bacteremia (SAB) is a high-risk condition associated with high morbidity and mortality. In the presence of cardiac implantable electronic devices (CIEDs), SAB may cause or clinically indicate device infection. We aimed to estimate the 10-year absolute risk of SAB in adult Danish first-time CIED carriers. Secondary aims included identification of risk factors associated with SAB. Methods A registry-based study utilizing Danish nationwide registers and including consecutive Danish patients undergoing first CIED implantation between 2000 and 2020 was conducted. The primary outcome was first-time SAB after CIED implantation. Results A total of 87 257 patients with first CIED implantation in the study period were identified (median age, 75 years; 62.6% were male; median follow-up, 3.8 years). Patients with pacemakers (PMs) were older and with more noncardiovascular comorbidities compared to patients with implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy devices with or without defibrillator capacity (CRTs). In total, 1366 patients (1.6%) developed SAB. The 10-year absolute risk (95% confidence interval) of SAB was 2.0% (1.9%-2.1%) for PM, 2.6% (2.2%-3.1%) for ICD, and 3.7% (3.0%-4.5%) for CRT. A multivariable Cox analysis identified hemodialysis (hazard ratio [HR], 8.51), SAB before CIED (HR, 2.76), liver disease (HR, 2.35), and carrying a CRT device (HR, 1.68) among the covariates associated with increased risk of SAB. Conclusions The absolute risk of SAB in Danish CIED carriers increased with more advanced CIED systems. The risk was highest within the first 3 months after CIED implantation and increased with the presence of certain covariates including renal dialysis, SAB before CIED, male sex, and advancing age.
Collapse
Affiliation(s)
| | | | - Melanie Vuong Le
- Department of Cardiology, Zealand University Hospital, Roskilde, Denmark
| | - Ketil Haugan
- Department of Cardiology, Zealand University Hospital, Roskilde, Denmark
| | | | | | | | - Sam Riahi
- Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark
| | | | - Charlotte Larroudé
- Department of Cardiology, Herlev and Gentofte University Hospital, Copenhagen, Denmark
| | - Andreas Petersen
- Department of Bacteria, Fungi and Parasites, National Reference Laboratory for Antimicrobial Resistance, Statens Serum Institut, Copenhagen, Denmark
| | - Anders Rhod Larsen
- Department of Bacteria, Fungi and Parasites, National Reference Laboratory for Antimicrobial Resistance, Statens Serum Institut, Copenhagen, Denmark
| | | | - Emil Fosbøl
- Department of Cardiology, Rigshospitalet, Copenhagen, Denmark
| | - Niels Eske Bruun
- Department of Cardiology, Zealand University Hospital, Roskilde, Denmark
| | - Anne-Christine Ruwald
- Department of Cardiology, Zealand University Hospital, Roskilde, Denmark
- Department of Cardiology, Rigshospitalet, Copenhagen, Denmark
| |
Collapse
|
4
|
Wattanachayakul P, Yanpiset P, Suenghataiphorn T, Srikulmontri T, Danpanichkul P, Rujirachun P, Polpichai N, Saowapa S, Casipit BA, Suparan K, Amanullah A. Impact of COVID-19 infection among patients hospitalized for conventional pacemaker implantation: Analysis of the Nationwide Inpatient Sample (NIS) 2020. J Arrhythm 2024; 40:905-912. [PMID: 39139863 PMCID: PMC11317689 DOI: 10.1002/joa3.13089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 05/06/2024] [Accepted: 05/21/2024] [Indexed: 08/15/2024] Open
Abstract
Introduction The cardiac pacemaker is indicated for treating various types of bradyarrhythmia, providing lifelong cardiovascular benefits. Recent data showed that COVID-19 has impacted procedure numbers and led to adverse long-term outcomes in patients with cardiac pacemakers. However, the impact of COVID-19 infection on the in-hospital outcome of patients undergoing conventional pacemaker implantation remains unclear. Method Patients aged above 18 years who were hospitalized for conventional pacemaker implantation in the Nationwide In-patient Sample (NIS) 2020 were identified using relevant ICD-10 CM and PCS codes. Multivariable logistic and linear regression models were used to analyze pre-specified outcomes, with the primary outcome being in-patient mortality and secondary outcomes including system-based and procedure-related complications. Results Of 108 020 patients hospitalized for conventional pacemaker implantation, 0.71% (765 out of 108 020) had a concurrent diagnosis of COVID-19 infection. Individuals with COVID-19 infection exhibited a lower mean age (73.7 years vs. 75.9 years, p = .027) and a lower female proportion (39.87% vs. 47.60%, p = .062) than those without COVID-19. In the multivariable logistic and linear regression models, adjusted for patient and hospital factors, COVID-19 infection was associated with higher in-hospital mortality (aOR 4.67; 95% CI 2.02 to 10.27, p < .001), extended length of stay (5.23 days vs. 1.04 days, p < .001), and linked with various in-hospital complications, including sepsis, acute respiratory failure, post-procedural pneumothorax, and venous thromboembolism. Conclusion Our study suggests that COVID-19 infection is attributed to higher in-hospital mortality, extended hospital stays, and increased adverse in-hospital outcomes in patients undergoing conventional pacemaker implantation.
Collapse
Affiliation(s)
- Phuuwadith Wattanachayakul
- Department of MedicineJefferson Einstein HospitalPhiladelphiaPennsylvaniaUSA
- Sidney Kimmel Medical CollegeThomas Jefferson UniversityPhiladelphiaPennsylvaniaUSA
| | - Panat Yanpiset
- Faculty of Medicine Chiang Mai UniversityChiang MaiThailand
| | | | | | - Pojsakorn Danpanichkul
- Immunology Unit, Department of Microbiology, Faculty of MedicineChiang Mai UniversityChiang MaiThailand
| | | | | | | | - Bruce A. Casipit
- Department of MedicineJefferson Einstein HospitalPhiladelphiaPennsylvaniaUSA
- Sidney Kimmel Medical CollegeThomas Jefferson UniversityPhiladelphiaPennsylvaniaUSA
| | - Kanokphong Suparan
- Immunology Unit, Department of Microbiology, Faculty of MedicineChiang Mai UniversityChiang MaiThailand
| | - Aman Amanullah
- Sidney Kimmel Medical CollegeThomas Jefferson UniversityPhiladelphiaPennsylvaniaUSA
- Division of Cardiovascular DiseaseJefferson Einstein HospitalPhiladelphiaPennsylvaniaUSA
| |
Collapse
|
5
|
Alaoui-Ismaili Z, Klein A, Moeller JE, Bo Lindhardt T, Hassager C. Cardiac tamponade due to right coronary artery perforation following pacemaker implantation: a case report. Eur Heart J Case Rep 2024; 8:ytae343. [PMID: 39071535 PMCID: PMC11276959 DOI: 10.1093/ehjcr/ytae343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 02/21/2024] [Accepted: 07/03/2024] [Indexed: 07/30/2024]
Abstract
Background Cardiac tamponade due to perforation of a cardiac chamber is a rare complication occurring in only 0.3% of patients undergoing permanent pacemaker (PM) implantation. Notably, perforation of the right coronary artery (RCA) following permanent PM implantation has only been reported twice in the literature. We report a rare case of RCA perforation leading to life-threatening cardiac tamponade with symptom onset 4 days after PM implantation. Case summary A 75-year-old woman underwent permanent PM implantation without any difficulties in placing pacemaker leads and with good thresholds. Four days later, the patient was readmitted in a state of shock due to cardiac tamponade. A blood gas analysis on the bloody pericardial effusion raised suspicion of ongoing arterial bleeding. A CT scan ruled out aortic dissection; instead, the source of bleeding was identified as a perforation in the RCA, which was managed surgically. Discussion This case highlights the necessity of coronary artery perforation being among the differential diagnoses of cardiac tamponade after PM implantation, and it stresses the usefulness of performing a blood gas analysis on the bloody pericardial effusion.
Collapse
Affiliation(s)
- Zakaria Alaoui-Ismaili
- Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen Ø, Denmark
| | - Anika Klein
- Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen Ø, Denmark
| | - Jacob Eifer Moeller
- Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen Ø, Denmark
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | - Christian Hassager
- Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen Ø, Denmark
| |
Collapse
|
6
|
Schvartz N, Haidary A, Wakili R, Hecker F, Kupusovic J, Zsigmond EJ, Miklos M, Saghy L, Szili-Torok T, Erath JW, Vamos M. Risk of Cardiac Implantable Electronic Device Infection after Early versus Delayed Lead Repositioning. J Cardiovasc Dev Dis 2024; 11:117. [PMID: 38667735 PMCID: PMC11049932 DOI: 10.3390/jcdd11040117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 02/01/2024] [Accepted: 02/03/2024] [Indexed: 04/28/2024] Open
Abstract
(1) Background: Early reintervention increases the risk of infection of cardiac implantable electronic devices (CIEDs). Some operators therefore delay lead repositioning in the case of dislocation by weeks; however, there is no evidence to support this practice. The aim of our study was to evaluate the impact of the timing of reoperation on infection risk. (2) Methods: The data from consecutive patients undergoing lead repositioning in two European referral centers were retrospectively analyzed. The odds ratio (OR) of CIED infection in the first year was compared among patients undergoing early (≤1 week) vs. delayed (>1 week to 1 year) reoperation. (3) Results: Out of 249 patients requiring CIED reintervention, 85 patients (34%) underwent an early (median 2 days) and 164 (66%) underwent a delayed lead revision (median 53 days). A total of nine (3.6%) wound/device infections were identified. The risk of infection was numerically lower in the early (1.2%) vs. delayed (4.9%) intervention group yielding no statistically significant difference, even after adjustment for typical risk factors for CIED infection (adjusted OR = 0.264, 95% CI 0.032-2.179, p = 0.216). System explantation/extraction was necessary in seven cases, all being revised in the delayed group. (4) Conclusions: In this bicentric, international study, delayed lead repositioning did not reduce the risk of CIED infection.
Collapse
Affiliation(s)
- Noemi Schvartz
- Cardiology Center/Cardiac Electrophysiology Division, Internal Medicine Clinic, University of Szeged, 6725 Szeged, Hungary; (N.S.)
| | - Arian Haidary
- Department of Cardiology, Division of Clinical Electrophysiology, Goethe University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Reza Wakili
- Department of Cardiology, Division of Clinical Electrophysiology, Goethe University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Florian Hecker
- Department of Cardiac Surgery, Goethe University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Jana Kupusovic
- Department of Cardiology, Division of Clinical Electrophysiology, Goethe University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Elod-Janos Zsigmond
- Doctoral School of Clinical Medicine, University of Szeged, 6725 Szeged, Hungary
- Central Hospital of Northern Pest—Military Hospital, 1134 Budapest, Hungary
| | - Marton Miklos
- Cardiology Center/Cardiac Electrophysiology Division, Internal Medicine Clinic, University of Szeged, 6725 Szeged, Hungary; (N.S.)
| | - Laszlo Saghy
- Cardiology Center/Cardiac Electrophysiology Division, Internal Medicine Clinic, University of Szeged, 6725 Szeged, Hungary; (N.S.)
| | - Tamas Szili-Torok
- Cardiology Center/Cardiac Electrophysiology Division, Internal Medicine Clinic, University of Szeged, 6725 Szeged, Hungary; (N.S.)
| | - Julia W. Erath
- Department of Cardiology, Division of Clinical Electrophysiology, Goethe University Hospital Frankfurt, 60596 Frankfurt am Main, Germany
| | - Mate Vamos
- Cardiology Center/Cardiac Electrophysiology Division, Internal Medicine Clinic, University of Szeged, 6725 Szeged, Hungary; (N.S.)
| |
Collapse
|
7
|
Diaz JC, Duque M, Miranda-Arboleda AF, Koplan BA, Marín JE, Aristizabal JM, Niño CD, Bastidas O, Hincapie D, Hoyos C, Matos CD, Lopez-Cabanillas N, Jaraba E, Moreno S, Caceres M, Ruiz LM, Sauer WH, Romero JE. Single-/dual-chamber vs cardiac resynchronization pacemakers for cardiac resynchronization. Heart Rhythm 2024; 21:499-501. [PMID: 38181988 DOI: 10.1016/j.hrthm.2023.12.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 12/27/2023] [Accepted: 12/29/2023] [Indexed: 01/07/2024]
Affiliation(s)
- Juan C Diaz
- Cardiac Arrhythmia and Electrophysiology Service, Division of Cardiology, Clinica Las Vegas, Universidad CES Medical School, Medellin, Colombia.
| | - Mauricio Duque
- Cardiac Arrhythmia Service, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Andres F Miranda-Arboleda
- Cardiac Arrhythmia and Electrophysiology Service, Hospital San Vicente Fundación, Rionegro, Colombia
| | - Bruce A Koplan
- Cardiac Arrhythmia and Electrophysiology Service, Hospital San Vicente Fundación, Rionegro, Colombia
| | - Jorge E Marín
- Cardiac Arrhythmia and Electrophysiology Service, Division of Cardiology, Department of Medicine, Clinica Las Americas, Medellin, Colombia
| | - Julian M Aristizabal
- Cardiac Arrhythmia and Electrophysiology Service, Hospital San Vicente Fundación, Rionegro, Colombia
| | - Cesar D Niño
- Cardiac Arrhythmia and Electrophysiology Service, Clinica SOMER, Rionegro, Antioquia, Colombia
| | - Oriana Bastidas
- Cardiac Arrhythmia and Electrophysiology Service, Division of Cardiology, Clinica Las Vegas, Universidad CES Medical School, Medellin, Colombia
| | - Daniela Hincapie
- Cardiac Arrhythmia and Electrophysiology Service, Hospital San Vicente Fundación, Rionegro, Colombia
| | - Carolina Hoyos
- Cardiac Arrhythmia and Electrophysiology Service, Hospital San Vicente Fundación, Rionegro, Colombia
| | - Carlos D Matos
- Cardiac Arrhythmia and Electrophysiology Service, Hospital San Vicente Fundación, Rionegro, Colombia
| | | | - Elmer Jaraba
- Cardiac Arrhythmia and Electrophysiology Service, Division of Cardiology, Department of Medicine, Clinica Las Americas, Medellin, Colombia
| | | | | | | | - William H Sauer
- Cardiac Arrhythmia and Electrophysiology Service, Hospital San Vicente Fundación, Rionegro, Colombia
| | - Jorge E Romero
- Cardiac Arrhythmia and Electrophysiology Service, Hospital San Vicente Fundación, Rionegro, Colombia
| |
Collapse
|
8
|
Frausing MHJP, Nielsen JC, Westergaard CL, Gerdes C, Kjellberg J, Boriani G, Kronborg MB. Economic analyses in cardiac electrophysiology: from clinical efficacy to cost utility. Europace 2024; 26:euae031. [PMID: 38289720 PMCID: PMC10858642 DOI: 10.1093/europace/euae031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 01/24/2024] [Indexed: 02/01/2024] Open
Abstract
Cardiac electrophysiology is an evolving field that relies heavily on costly device- and catheter-based technologies. An increasing number of patients with heart rhythm disorders are becoming eligible for cardiac interventions, not least due to the rising prevalence of atrial fibrillation and increased longevity in the population. Meanwhile, the expansive costs of healthcare face finite societal resources, and a cost-conscious approach to new technologies is critical. Cost-effectiveness analyses support rational decision-making in healthcare by evaluating the ratio of healthcare costs to health benefits for competing therapies. They may, however, be subject to significant uncertainty and bias. This paper aims to introduce the basic concepts, framework, and limitations of cost-effectiveness analyses to clinicians including recent examples from clinical electrophysiology and device therapy.
Collapse
Affiliation(s)
- Maria Hee Jung Park Frausing
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Bvld 99, DK-8200 Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Bvld. 99, DK-8200 Aarhus, Denmark
| | - Jens Cosedis Nielsen
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Bvld 99, DK-8200 Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Bvld. 99, DK-8200 Aarhus, Denmark
| | - Caroline Louise Westergaard
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Christian Gerdes
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Bvld 99, DK-8200 Aarhus, Denmark
| | - Jakob Kjellberg
- The Danish Center for Social Science Research, VIVE, Copenhagen, Denmark
| | - Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | - Mads Brix Kronborg
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Bvld 99, DK-8200 Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Bvld. 99, DK-8200 Aarhus, Denmark
| |
Collapse
|
9
|
Awad AK, Sayed A, Elbadawy MA, Ahmed A, Ming Wang TK, Elgharably H. Concomitant tricuspid valve repair for mild-moderate tricuspid regurgitation patients undergoing mitral valve surgery? A meta-analysis and meta-regression. THE JOURNAL OF CARDIOVASCULAR SURGERY 2023; 64:657-667. [PMID: 37486236 DOI: 10.23736/s0021-9509.23.12760-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/25/2023]
Abstract
The development of tricuspid regurgitation (TR) is a common complication of mitral valve disease. Although severe TR is usually operated on at the same time of mitral valve surgery (MVS), controversies remain regarding whether mild to moderate TR patients should be operated. Concomitant tricuspid valve repair with MVS for mild-moderate TR patients. Electronic databases were searched from inception to November 20, 2022 to include any observational or randomized controlled trials (RCT) that compare concomitant tricuspid repair with MVS versus MVS alone. Mantel-Haenszel method was used to pool study estimates and calculate odds ratios (OR) with 95% confidence intervals (CI). A total of 9813 patients from 25 studies were included. Regarding primary outcomes, concomitant repair group had significantly lower 30 days mortality (OR: 0.66; 95% CI 0.45 to 0.96), all-cause mortality-based on RCTs- (OR: 0.40; 95% CI 0.22 to 0.71), cardiovascular mortality (OR: 0.53; 95% CI: 0.33 to 0.86) and heart failure hospitalizations (OR: 0.41; 95% CI: 0.26 to 0.63). However, was associated with higher permanent pacemaker implantation rates (OR: 2.09; 95% CI: 1.45 to 3.00). There were no significant differences in terms of secondary outcomes: tricuspid valve reinterventions, stroke and acute kidney injury. Furthermore, repair group showed lower risk for TR progression degrees (OR 0.08; 95% CI 0.05 to 0.16) and decreased mean of TR progression (MD -1.85; 95% CI -1.92 to -1.77). Concomitant tricuspid valve repair in mild or moderate TR at time of MVS appears to reduce not only 30 days but also long-term all-cause and cardiovascular mortality weighed against the increased risk of pacemaker implantation.
Collapse
Affiliation(s)
- Ahmed K Awad
- Faculty of Medicine, Ain-shams University, Cairo, Egypt -
| | - Ahmed Sayed
- Faculty of Medicine, Ain-shams University, Cairo, Egypt
| | | | | | - Tom K Ming Wang
- Department of Cardiovascular Medicine, Heart Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Haytham Elgharably
- Department of Thoracic and Cardiovascular Surgery, Heart Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
10
|
Defaye P, Biffi M, El-Chami M, Boveda S, Glikson M, Piccini J, Vitolo M. Cardiac pacing and lead devices management: 25 years of research at EP Europace journal. Europace 2023; 25:euad202. [PMID: 37421338 PMCID: PMC10450798 DOI: 10.1093/europace/euad202] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 07/03/2023] [Indexed: 07/10/2023] Open
Abstract
AIMS Cardiac pacing represents a key element in the field of electrophysiology and the treatment of conduction diseases. Since the first issue published in 1999, EP Europace has significantly contributed to the development and dissemination of the research in this area. METHODS In the last 25 years, there has been a continuous improvement of technologies and a great expansion of clinical indications making the field of cardiac pacing a fertile ground for research still today. Pacemaker technology has rapidly evolved, from the first external devices with limited longevity, passing through conventional transvenous pacemakers to leadless devices. Constant innovations in pacemaker size, longevity, pacing mode, algorithms, and remote monitoring highlight that the fascinating and exciting journey of cardiac pacing is not over yet. CONCLUSION The aim of the present review is to provide the current 'state of the art' on cardiac pacing highlighting the most important contributions from the Journal in the field.
Collapse
Affiliation(s)
- Pascal Defaye
- Cardiology Department, University Hospital and Grenoble Alpes University, CS 10217, Grenoble Cedex 9, Grenoble 38043, France
| | - Mauro Biffi
- Cardiology Unit, Cardiac Thoracic and Vascular Department, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Mikhael El-Chami
- Department of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, Georgia, USA
| | - Serge Boveda
- Clinique Pasteur, Heart Rhythm Department, Toulouse, France
| | - Michael Glikson
- Cardiology Department, Jesselson Integrated Heart Center Shaare Zedek Medical Center and Hebrew University Faculty of Medicine, Jerusalem, Israel
| | - Jonathan Piccini
- Duke University, Duke Clinical Research Institute, Durham, NC, USA
| | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Modena, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| |
Collapse
|
11
|
Budrejko S, Kempa M, Rohun J, Daniłowicz-Szymanowicz L, Zienciuk-Krajka A, Faran A, Raczak G. Application of Novel Technologies in Cardiac Electrotherapy to Prevent Complications. Diagnostics (Basel) 2023; 13:1584. [PMID: 37174974 PMCID: PMC10178181 DOI: 10.3390/diagnostics13091584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 04/22/2023] [Accepted: 04/26/2023] [Indexed: 05/15/2023] Open
Abstract
(1) Background: Cardiac electrotherapy is developing quickly, which implies that it will face a higher number of complications, with cardiac device-related infective endocarditis (CDRIE) being the most frequent, but not the only one. (2) Methods: This is a retrospective case study followed by a literature review, which presents a patient with a rare but dangerous complication of electrotherapy, which could have been prevented if modern technology had been used. (3) Results: A 34-year-old female was admitted with suspicion of CDRIE based on an unclear echocardiographic presentation. However, with no signs of infection, that diagnosis was not confirmed, though an endocardial implantable cardioverter-defibrillator (ICD) lead was found folded into the pulmonary trunk. The final treatment included transvenous lead extraction (TLE) and subcutaneous ICD (S-ICD) implantation. (4) Conclusions: With the increasing number of implantations of cardiac electronic devices and their consequences, a high index of suspicion among clinicians is required. The entity of the clinical picture must be thoroughly considered, and various diagnostic tools should be applied. Lead dislocation into the pulmonary trunk is an extremely rare complication. Our findings align with the available literature data, where asymptomatic cases are usually effectively treated with TLE. Modern technologies, such as S-ICD, can effectively prevent lead-related problems and are indicated in young patients necessitating long-term ICD therapy.
Collapse
Affiliation(s)
| | | | | | - Ludmiła Daniłowicz-Szymanowicz
- Department of Cardiology and Electrotherapy, Medical University of Gdansk, 80-214 Gdansk, Poland; (S.B.); (M.K.); (J.R.); (A.Z.-K.); (A.F.); (G.R.)
| | | | | | | |
Collapse
|
12
|
Imberti JF, Mei DA, Fontanesi R, Gerra L, Bonini N, Vitolo M, Turco V, Casali E, Boriani G. Low Occurrence of Infections and Death in a Real-World Cohort of Patients with Cardiac Implantable Electronic Devices. J Clin Med 2023; 12:2599. [PMID: 37048682 PMCID: PMC10095352 DOI: 10.3390/jcm12072599] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/10/2023] [Accepted: 03/28/2023] [Indexed: 03/31/2023] Open
Abstract
BACKGROUND The incidence of infections and death in patients implanted with cardiac implantable electronic devices (CIEDs) is not fully known yet. AIM To describe the incidence of CIED-related infection and death, and their potential predictors in a contemporary cohort of CIED patients. METHODS All consecutive patients implanted with a CIED at our institution were prospectively enrolled. Follow-up visits were performed 2 weeks after CIED implantation for all patients, and then every 6 months for implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy (CRT) patients and every 12 months for pacemaker (PM) patients. The adjudication of CIED-related infections was performed by two independent investigators and potential disagreement was resolved by a senior investigator. RESULTS Between September 2016 and August 2020, a total of 838 patients were enrolled (34.6% female; median age 77 (69.6-83.6); median PADIT score 2 (2-4)). PMs were implanted in 569 (68%) patients and ICD/CRT in 269 (32%) patients. All patients had pre-implant antibiotic prophylaxis and 5.5% had an antibiotic-eluting envelope. Follow-up data were available for 832 (99.2%) patients. After a median follow-up of 42.3 (30.2-56.4) months, five (0.6%) patients had a CIED-related infection and 212 (25.5%) patients died. Using multivariate Cox regression analysis, end-stage chronic kidney disease (CKD) requiring dialysis and therapy with corticosteroids was independently associated with a higher risk of infection (hazard ratio (HR): 14.20; 95% confidence interval (CI) 1.48-136.62 and HR: 14.71; 95% CI 1.53-141.53, respectively). Age (HR: 1.07; 95% CI 1.05-1.09), end-stage CKD requiring dialysis (HR: 6.13; 95% CI 3.38-11.13) and history of atrial fibrillation (HR: 1.47; 95% CI 1.12-1.94) were independently associated with all-cause death. CONCLUSIONS In a contemporary cohort of CIED patients, mortality was substantially high and associated with clinical factors depicting a population at risk. On the other hand, the incidence of CIED-related infections was low.
Collapse
Affiliation(s)
- Jacopo Francesco Imberti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, 41125 Modena, Italy
| | - Davide Antonio Mei
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
| | - Riccardo Fontanesi
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
| | - Luigi Gerra
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
| | - Niccolò Bonini
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, 41125 Modena, Italy
| | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, 41125 Modena, Italy
| | - Vincenzo Turco
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
| | - Edoardo Casali
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
| | - Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
| |
Collapse
|
13
|
Olsen T, Jørgensen OD, Nielsen JC, Thøgersen AM, Philbert BT, Frausing MHJP, Sandgaard NCF, Johansen JB. Risk factors for cardiac implantable electronic device infections: a nationwide Danish study. Eur Heart J 2022; 43:4946-4956. [PMID: 36263789 PMCID: PMC9748591 DOI: 10.1093/eurheartj/ehac576] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 08/05/2022] [Accepted: 09/29/2022] [Indexed: 01/12/2023] Open
Abstract
AIMS Cardiac implantable electronic device (CIED) infection is a severe complication to modern management of cardiac arrhythmias. The CIED type and the type of surgery are recognized as risk factors for CIED infections, but knowledge of patient-related risk factors is scarce. This study aimed to identify lifelong patient-related risk factors for CIED infections. METHODS AND RESULTS Consecutive Danish patients undergoing a CIED implantation or reoperation between January 1996 and April 2018 were included. The cohort consisted of 84 429 patients undergoing 108 494 CIED surgeries with a combined follow-up of 458 257 CIED-years. A total of 1556 CIED explantations were classified as either pocket (n = 1022) or systemic CIED infection (n = 534). Data were cross-linked with records from the Danish National Patient Registry and the Danish National Prescription Registry. Using multiple-record and multiple-event per subject proportional hazard analysis, specific patient-related risk factors were identified but with several variations amongst the subtypes of CIED infection. CIED reoperations were associated with the highest risk of pocket CIED infection but also CIED type, young age, and prior valvular surgery [hazard ratio (HR): 1.62, 95% confidence interval (CI): 1.29-2.04]. Severe renal insufficiency/dialysis (HR: 2.40, 95% CI: 1.65-3.49), dermatitis (HR: 2.80, 95% CI: 1.92-4.05), and prior valvular surgery (HR: 2.09, 95% CI: 1.59-2.75) were associated with the highest risk of systemic CIED infections. Congestive heart failure, ischaemic heart disease, malignancy, chronic obstructive pulmonary disease, and temporary pacing were not significant at multivariate analysis. CONCLUSION Specific comorbidities and surgical procedures were associated with a higher risk of CIED infections but with variations amongst pocket and systemic CIED infection. Pocket CIED infections were associated with CIED reoperations, young age and more complex type of CIED, whereas systemic CIED infections were associated with risk factors predisposing to bacteraemia.
Collapse
Affiliation(s)
- Thomas Olsen
- Corresponding author. Tel: +45 2635 1337, Fax: +45 6541 3003,
| | - Ole Dan Jørgensen
- Department of Heart, Lung and Vascular Surgery, Odense University Hospital, J. B. Winsløws Vej 4, 5000 Odense, Region of Southern Denmark, Denmark,Danish Pacemaker and ICD Register, Department of Cardiology, Odense University Hospital, J. B. Winsløws Vej 4, 5000 Odense, Region of Southern Denmark, Denmark
| | - Jens Cosedis Nielsen
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus, Central Denmark Region, Denmark,Danish Pacemaker and ICD Register, Department of Cardiology, Odense University Hospital, J. B. Winsløws Vej 4, 5000 Odense, Region of Southern Denmark, Denmark
| | - Anna Margrethe Thøgersen
- Department of Cardiology, Aalborg University Hospital, Hobrovej 18-22, 9000 Aalborg, North Denmark Region, Denmark
| | - Berit Thornvig Philbert
- Department of Cardiology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Capital Region of Denmark, Denmark,Danish Pacemaker and ICD Register, Department of Cardiology, Odense University Hospital, J. B. Winsløws Vej 4, 5000 Odense, Region of Southern Denmark, Denmark
| | - Maria Hee Jung Park Frausing
- Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus, Central Denmark Region, Denmark
| | | | | |
Collapse
|
14
|
Woodard DA, Kim G, Nilsson KR. Risk profiles and outcomes of patients receiving antibacterial cardiovascular implantable electronic device envelopes: A retrospective analysis. World J Cardiol 2022; 14:177-186. [PMID: 35432770 PMCID: PMC8968457 DOI: 10.4330/wjc.v14.i3.177] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 02/08/2022] [Accepted: 03/17/2022] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Cardiovascular implantable electronic devices (CIEDs) are implanted in an increasing number of patients each year, which has led to an increase in the risk of CIED infection. Antibacterial CIED envelopes locally deliver antibiotics to the implant site over a short-term period and have been shown to reduce the risk of implant site infection. These envelopes are derived from either biologic or non-biologic materials. There is a paucity of data examining patient risk profiles and outcomes from using these envelope materials in the clinical setting and comparing these results to patients receiving no envelope with their CIED implantation.
AIM To evaluate risk profiles and outcomes of patients who underwent CIED procedures with an antibacterial envelope or no envelope.
METHODS After obtaining Internal Review Board approval, the records of consecutive patients who underwent a CIED implantation procedure by a single physician between March 2017 and December 2019 were retrospectively collected from our hospital. A total of 248 patients within this period were identified and reviewed through 12 mo of follow up. The CIED procedures used either no envelope (n = 57), a biologic envelope (CanGaroo®, Aziyo Biologics) that was pre-hydrated by the physician with vancomycin and gentamicin (n = 89), or a non-biologic envelope (Tyrx™, Medtronic) that was coated with a resorbable polymer containing the drug substances rifampin and minocycline by the manufacturer (n = 102). Patient selection for receiving either no envelope or an envelope (and which envelope to use) was determined by the treating physician. Statistical analyses were performed between the 3 groups (CanGaroo, Tyrx, and no envelope), and also between the No Envelope and Any Envelope groups by an independent, experienced biostatistician.
RESULTS On average, patients who received any envelope (biologic or non-biologic) were younger (70.7 ± 14.0 vs 74.9 ± 10.6, P = 0.017), had a greater number of infection risk factors (81.2% vs 49.1%, P < 0.001), received more high-powered devices (37.2% vs 5.8%, P = 0.004), and were undergoing more reoperative procedures (47.1% vs 0.0%, P < 0.001) than patients who received no envelope. Between the two envelopes, biologic envelopes tended to be used more often in higher risk patients (84.3% vs 78.4%) and reoperative procedures (62.9% vs 33.3%) than non-biologic envelopes. The rate of CIED implant site pocket infection was low (any envelope 0.5% vs no envelope 0.0%) and was statistically equivalent between the two envelope groups. Other reported adverse events (lead dislodgement, lead or pocket revision, device migration or erosion, twiddler’s syndrome, and erythema/fever) were low and statistically equivalent between groups (biologic 2.2%, non-biologic 3.9%, no envelope 1.8%).
CONCLUSION CIED infection rates for biologic and non-biologic antibacterial envelopes are similar. Antibacterial envelopes may benefit patients who are higher risk for infection, however additional studies are warranted to confirm this.
Collapse
Affiliation(s)
- David A Woodard
- Department of Cardiology, Piedmont Heart Institute, Athens, GA 30606, United States
| | - Grace Kim
- Department of Medicine, Augusta University-University of Georgia Medical Partnership, Athens, GA 30606, United States
| | - Kent R Nilsson
- Department of Cardiology, Piedmont Heart Institute, Athens, GA 30606, United States
- Department of Medicine, Augusta University-University of Georgia Medical Partnership, Athens, GA 30606, United States
| |
Collapse
|
15
|
Cosgun MS, Cosgun C. Efficacy and safety of different exercises in preventing cardiac implantable electronic device-related shoulder impairment. Pacing Clin Electrophysiol 2022; 45:384-392. [PMID: 35146785 DOI: 10.1111/pace.14465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 01/11/2022] [Accepted: 01/30/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND Shoulder impairment on the implant-side is common after cardiac implantable electronic device (CIED) implantation. The aim of this study was to compare the efficacy and safety of the pendulum exercise (PE) and stretching & strengthening exercises (SSE) in preventing postimplantation shoulder impairment. METHODS This prospective, randomized study collected data from 89 patients, including 30 in a control group, 31 in a PE group, and 28 in a SSE group. Shoulder functions on the implant-side were evaluated by grip strength (GS), range of motion (ROM), Visual Analog Scale (VAS), Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH), and 36-Item Short-Form Survey (SF-36). RESULTS Shoulder median flexion and abduction ROM were significantly improved two-month postimplantation compared to two-week postimplantation in PE (156±11 vs. 146±10, p = .002; 147±9 vs. 136±9, p = .001, respectively) and SSE (158±13 vs. 147±11, p = .003; 149±13 vs. 138±9, p = .002, respectively) groups, but not in the control group. Two months after implantation, the two exercise groups showed no significant differences in any assessment. Compared with the PE and SSE groups, the control group had significantly lower GS (p = .012 and p = .002, respectively) and SF-36 physical component summary (p = .007 and p = .003, respectively) and significantly higher VAS (p = .003 and p = .001, respectively) and QuickDASH (p = .002 and p = .005, respectively) scores two-month postimplantation. CONCLUSIONS PE and SSE for the ipsilateral upper arm starting two-week after CIED implantation provided similar benefits in preserving shoulder girdle muscle strength, maintaining shoulder motion, relieving shoulder pain, preventing shoulder injury, and improving quality of life, without the risk of lead dislodgement. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Muharrem Said Cosgun
- Department of Cardiology, Mengucek Gazi Education and Research Hospital, Medical Faculty, Erzincan Binali Yildirim University, Erzincan, Turkey
| | - Cansu Cosgun
- Department of Physical Therapy and Rehabilitation, Mengucek Gazi Education and Research Hospital, Medical Faculty, Erzincan Binali Yildirim University, Erzincan, Turkey
| |
Collapse
|
16
|
Cosgun MS, Cosgun C. Predictors of shoulder limitations and disability in patients with cardiac implantable electronic devices: Importance of device size. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021; 44:1979-1986. [PMID: 34624142 DOI: 10.1111/pace.14378] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 08/17/2021] [Accepted: 10/03/2021] [Indexed: 12/20/2022]
Abstract
BACKGROUND Generator-induced shoulder impairment is a common complication of cardiac implantable electronic device (CIED) implantation. Although implantable cardioverter-defibrillators (ICDs) have become smaller in size, they are still bigger than pacemakers (PMs). This study aimed to investigate the effects of single-chamber PM and ICD sizes on shoulder function. METHODS This retrospective study included 200 consecutive patients, of whom 123 had PMs and 77 had ICDs. The CIED implantation effects on shoulder function, pain, disability, and quality of life (QoL) were evaluated. The range of motion (ROM), Visual Analog Scale (VAS), Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH), and Short Form-36 (SF-36) Health Survey (Physical and Mental Component Summary [PCS and MCS]) were used. RESULTS The flexion and abduction range limitation rates were significantly higher in the ICD group than in the PM group (16.9% vs. 7.3%, p = .035 and 19.5% vs. 8.9%, p = .031, respectively). The two groups had similar VAS scores. The median QuickDASH score was significantly higher in the ICD group than in the PM group (8.2 [3.6-19.6] vs. 4.6 [2.6-17.9], p = .034). There were no significant differences in SF-36 components between the two groups. ICD implantation (OR: 1.642, 95% CI: 1.293-2.776; p = .001) and incision length (OR: 1.343, 95% CI: 1.194-2.064; p = .01) were independent predictors of shoulder ROM limitations. CONCLUSIONS Reduced device sizes with advancing technology can decrease shoulder functional limitations and disability after implantation. Healthcare professionals should not neglect shoulder evaluations during the pre- and postimplantation periods.
Collapse
Affiliation(s)
- Muharrem Said Cosgun
- Department of Cardiology, Mengucek Gazi Education and Research Hospital, Medical Faculty, Erzincan Binali Yildirim University, Erzincan, Turkey
| | - Cansu Cosgun
- Department of Physical Therapy and Rehabilitation, Mengucek Gazi Education and Research Hospital, Medical Faculty, Erzincan Binali Yildirim University, Erzincan, Turkey
| |
Collapse
|