1
|
Phase I/II study of stereotactic body radiotherapy boost in patients with cervical cancer ineligible for intracavitary brachytherapy. Jpn J Radiol 2024:10.1007/s11604-024-01566-8. [PMID: 38625476 DOI: 10.1007/s11604-024-01566-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Accepted: 03/25/2024] [Indexed: 04/17/2024]
Abstract
PURPOSE Stereotactic body radiotherapy (SBRT) boost is a promising treatment for cervical cancer patients who are ineligible for intracavitary brachytherapy (ICBT). The aim of this multicenter, single-arm, phase I/II study was to prospectively evaluate the efficacy and toxicity of SBRT boost. MATERIALS AND METHODS ICBT-ineligible patients with untreated cervical cancer were enrolled. Patients underwent whole-pelvic radiotherapy (45 Gy in 25 fractions) with SBRT boost to the primary lesion. In the phase I dose-escalation cohort (3 + 3 design), patients were treated with SBRT boost of 21 or 22.5 Gy in three fractions. Although dose-limiting toxicity was not confirmed, a dose of 21 Gy was selected for the phase II cohort because it was difficult to reproduce the pelvic organs position in two patients during the phase I trial. The primary endpoint was 2-year progression-free survival. RESULTS Twenty-one patients (phase I, n = 3; phase II, n = 18) were enrolled between April 2016 and October 2020; 17 (81%) had clinical stage III-IV (with para-aortic lymph node metastases) disease. The median (range) follow-up was 40 (10-84) months. The initial response was complete response in 20 patients and partial response in one patient. The 2-year locoregional control, progression-free survival, and overall survival rates were 84%, 67%, and 81%, respectively. Grade ≥ 3 toxicity was confirmed in one patient each in the acute (diarrhea) and late (urinary tract obstruction) phases. CONCLUSION These findings suggested that a SBRT boost is more effective than the conventional EBRT boost and can be an important treatment option for ICBT-ineligible patients with cervical cancer. STUDY REGISTRATION This study was registered at the University Hospital Medical Information Network Clinical Trials Registry (UMIN000036845).
Collapse
|
2
|
Reduced Risk of Lymphedema With Intensity-modulated Radiation Therapy Compared With 3-dimensional Conformal Radiation Therapy in Patients With Cervical Cancer Who Received Postoperative Pelvic Radiation Therapy. Am J Clin Oncol 2023; 46:346-352. [PMID: 37231540 DOI: 10.1097/coc.0000000000001018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
OBJECTIVES To compare the long-term adverse events of intensity-modulated radiation therapy (IMRT) with those of 3-dimensional conformal radiation therapy (3D-CRT) in patients with intermediate-risk and high-risk uterine cervical cancer who underwent postoperative pelvic radiation therapy (PORT). METHODS We reviewed the medical records of 177 patients with cervical cancer who underwent radical surgery and PORT. IMRT and 3D-CRT were administered to 93 and 84 patients, respectively. Follow-up and toxicity assessments were then carried out. RESULTS The median follow-up period was 63 months (range: 3 to 177). There was a significant difference in the follow-up period between the IMRT and 3D-CRT cohorts (median: 59 vs. 112 mo, P <0.0001). The crude incidences of acute grade 2+ and grade 3+ gastrointestinal toxicities were significantly lower with IMRT than with 3D-CRT (22.6% vs. 48.1%, P =0.002, and 3.2% vs. 11.1%, P =0.04, respectively). The Kaplan-Meier estimates of late toxicities revealed that IMRT significantly reduced grade 2+ genitourinary (GU) toxicity and lower-extremity lymphedema ([LEL] requiring intervention) compared with 3D-CRT ([6.8% vs. 15.2% at 5-year, P =0.048] and [3.1% vs. 14.6% at 5-year, P =0.0029], respectively). IMRT was the only significant predictor of reducing LEL risk. CONCLUSIONS The risks of acute gastrointestinal toxicity, late GU toxicity, and LEL from PORT for cervical cancer were reduced by IMRT. Lower inguinal doses may have contributed to a lower risk of developing LEL, which should be validated in future studies.
Collapse
|
3
|
Intensity-modulated radiation therapy with the central shielding technique for patients with uterine cervical cancer†. JOURNAL OF RADIATION RESEARCH 2023:rrad039. [PMID: 37321676 DOI: 10.1093/jrr/rrad039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 02/25/2023] [Indexed: 06/17/2023]
Abstract
We aimed to examine outcomes and toxicities of intensity-modulated radiation therapy (IMRT) with the central shielding (CS) technique for patients with uterine cervical cancer. This retrospective study included 54 patients with International Federation of Gynecology and Obstetrics IB-IVA cancer. Whole pelvic radiotherapy or extended-field radiotherapy were performed at the dose of 50.4 Gy in 28 fractions with helical tomotherapy (HT). Six patients had para-aortic lymph node metastases. The CS technique with HT was utilized after a total dose of 28.8-41.4 Gy to reduce doses to the rectum and bladder. The prescribed dose of intracavitary brachytherapy was mainly 18-24 Gy in three or four fractions at point A. Concurrent chemotherapy was used for 47 patients (87%). Median follow-up time was 56 months. Seventeen patients (31%) developed recurrence. The recurrence of the cervix was observed in two patients (4%). The 5-year rates of the locoregional control, progression-free survival (PFS) and overall survival were 79, 66 and 82%, respectively. Among several factors evaluated, histological type of adenocarcinoma was only a significantly worse prognostic factor for PFS by multivariate analysis (hazard ratio, 4.9 [95% confidence interval, 1.3-18], P = 0.018). Grade 2 or higher late toxicities were observed in nine patients (17%). Two patients (4%) each had grade 3 proctitis and grade 3 ileus, respectively. No grade 4 toxicity or treatment-related death was observed. The results suggest that IMRT with the CS technique allows a high local control without increasing the risk of complications for cervical cancer patients.
Collapse
|
4
|
Efficacy of lymph node dissection on stage IIICr of cervical cancer before CCRT: study protocol for a phase III, randomized controlled clinical trial (CQGOG0103). J Gynecol Oncol 2023; 34:e55. [PMID: 36998225 PMCID: PMC10157346 DOI: 10.3802/jgo.2023.34.e55] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 01/27/2023] [Accepted: 02/25/2023] [Indexed: 04/01/2023] Open
Abstract
BACKGROUND Cervical cancer is still present a major public health problem, especially in developing countries. In International Federation of Gynaecology and Obstetrics 2018, allowing assessment of retroperitoneal lymph nodes by imaging and/or pathological findings and, if deemed metastatic, the case is designated as stage IIIC (with r and p notations). Patients with lymph node metastases have lower overall survival (OS), progression free survival (PFS), and survival after recurrence, especially those who have unresectable macroscopical positive lymph nodes. Retrospective analysis suggests that there may be a benefit to debulking macroscopic nodes that would be otherwise difficult to sterilize with standard doses of radiation therapy. However, there are no prospective study reporting that resecting macroscopic nodes before concurrent chemoradiation therapy (CCRT) would improve PFS or OS of cervical cancer and no guidelines for surgical resection of bulky lymph nodes. The CQGOG0103 study is a prospective, multicenter and randomized controlled trial (RCT) evaluating lymph node dissection on stage IIICr of cervical cancer. METHODS Eligible patients are histologically confirmed cervical squamous cell carcinoma, adenocarcinoma, adeno-squamous cell carcinoma. Stage IIICr (confirmed by computed tomography [CT]/magnetic resonance imaging/positron emission tomography/CT) and the short diameter of image-positive lymph node ≥15 mm. 452 patients will be equally randomized to receive either CCRT (pelvic external-beam radiotherapy [EBRT]/extended-field EBRT + cisplatin [40 mg/m²] or carboplatin [the area under curve=2] every week for 5 cycles + brachytherapy) or open/minimally invasive pelvic and para-aortic lymph node dissection followed by CCRT. Randomization is stratified by status of para-aortic lymph node. The primary endpoint is PFS. Secondary endpoints are OS and surgical complications. A total of 452 patients will be enrolled from multiple hospitals in China within 4 years and followed up for 5 years. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT04555226.
Collapse
|
5
|
Plan quality association between dummy run and individual case review in a prospective multi-institutional clinical trial of postoperative cervical cancer patients treated with intensity-modulated radiotherapy: Japan Clinical Oncology Group study (JCOG1402). Radiother Oncol 2023; 183:109630. [PMID: 36934892 DOI: 10.1016/j.radonc.2023.109630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 03/08/2023] [Accepted: 03/10/2023] [Indexed: 03/19/2023]
Abstract
BACKGROUND AND PURPOSE The Japan Clinical Oncology Group (JCOG) 1402 conducted a multicenter clinical trial of postoperative intensity-modulated radiotherapy (IMRT) for high-risk uterine cervical cancer patients. We assess effectiveness of the quality assurance (QA) program in central review through dummy runs (DRs) performed before patient enrollment and post-treatment individual case review (ICR), and clarify the pitfalls in treatment planning. MATERIAL AND METHODS The ICRs were conducted using the same QA program as the DR for 214 plans. The deviations were compared with those demonstrated in the DRs, and the pitfalls were clarified. Fifteen face-to-face meetings were held with physicians at participating institutions to provide feedback. RESULTS Two-hundred and eighty-nine deviations and nine violations were detected in the 214 plans. The patterns of the deviations observed in the ICRs were similar to that in the DR. Frequent deviations were observed in clinical target volume (CTV) delineations, 50% in the DRs and 35% in the ICRs, respectively. In the ICRs, approximately 1.4 deviations/violations were observed per plan, which was lower than DR. Nine violations included inaccurate CTV delineation and improper PTV (planning target volume) margin, which had risks in loco-regional failures by inadequate dose coverage. CONCLUSIONS Our developed QA program commonly used in DR and ICR clarified the pitfalls in treatment plans. Although the frequent deviations in CTV delineations were observed in the ICR, the deviations decreased compared to that in the DR. More specified face-to-face meetings with participating institutions will be necessary to maintain the quality of IMRT in the clinical protocol. TRIAL REGISTRATION Japanese Clinical Trial Registry #: UMIN000027017 at https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000030672;language=J.
Collapse
|
6
|
Comprehensive clinical evaluation of deep learning-based auto-segmentation for radiotherapy in patients with cervical cancer. Front Oncol 2023; 13:1119008. [PMID: 37188180 PMCID: PMC10175826 DOI: 10.3389/fonc.2023.1119008] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Accepted: 04/13/2023] [Indexed: 05/17/2023] Open
Abstract
Background and purpose Deep learning-based models have been actively investigated for various aspects of radiotherapy. However, for cervical cancer, only a few studies dealing with the auto-segmentation of organs-at-risk (OARs) and clinical target volumes (CTVs) exist. This study aimed to train a deep learning-based auto-segmentation model for OAR/CTVs for patients with cervical cancer undergoing radiotherapy and to evaluate the model's feasibility and efficacy with not only geometric indices but also comprehensive clinical evaluation. Materials and methods A total of 180 abdominopelvic computed tomography images were included (training set, 165; validation set, 15). Geometric indices such as the Dice similarity coefficient (DSC) and the 95% Hausdorff distance (HD) were analyzed. A Turing test was performed and physicians from other institutions were asked to delineate contours with and without using auto-segmented contours to assess inter-physician heterogeneity and contouring time. Results The correlation between the manual and auto-segmented contours was acceptable for the anorectum, bladder, spinal cord, cauda equina, right and left femoral heads, bowel bag, uterocervix, liver, and left and right kidneys (DSC greater than 0.80). The stomach and duodenum showed DSCs of 0.67 and 0.73, respectively. CTVs showed DSCs between 0.75 and 0.80. Turing test results were favorable for most OARs and CTVs. No auto-segmented contours had large, obvious errors. The median overall satisfaction score of the participating physicians was 7 out of 10. Auto-segmentation reduced heterogeneity and shortened contouring time by 30 min among radiation oncologists from different institutions. Most participants favored the auto-contouring system. Conclusion The proposed deep learning-based auto-segmentation model may be an efficient tool for patients with cervical cancer undergoing radiotherapy. Although the current model may not completely replace humans, it can serve as a useful and efficient tool in real-world clinics.
Collapse
|
7
|
Dose to pelvic lymph nodes during brachytherapy of locally advanced cervical cancer with 60Co HDR source. Brachytherapy 2021; 21:158-169. [PMID: 34750084 DOI: 10.1016/j.brachy.2021.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 09/27/2021] [Accepted: 09/29/2021] [Indexed: 11/17/2022]
Abstract
PURPOSE This study investigated the correlation between the prescription dose and dose to the Manchester and International Commission on Radiation Units and Measurements-report 38 (ICRU-38) lymphatic trapezoid points during high-dose-rate (HDR) brachytherapy of locally advanced cervical cancer with (Cobalt-60) 60Co . METHODS AND MATERIALS A retrospective study was designed for; patients with locally advanced cervical cancer, treated by external beam radiotherapy and concurrent weekly Cisplatin-based chemotherapy, had no extended parametrial invasion and was treated by tandem-ovoid set, from 2017 to 2020. Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO) based target's volume, ICRU-89 revised version of Manchester points A and B, and ICRU-38 lymph node surrogate points were determined, and their dose was recorded. Paired sample t-test, linear regression analysis, and Pearson correlation analyses were done considering a statistical significance level of 0.05 and using IBM SPSS statistics (Version 23, IBM Crop.). RESULTS Seventy-four brachytherapy cases were included. A positive and strong correlation was observed between D90 of clinical target volume (CTVHR) and points A and B dose for CTVHR〈 15 cc and 〉 35 cc. Strong and significant (p < 0.05) correlations were achieved between pelvic wall points dose and D90 and D100 of the obturator and between D50 and hot points of internal iliac lymph nodes. A strong correlation was obtained between D50 and D90 of external iliac lymph nodes and their ICRU points. CONCLUSIONS Strong correlations were obtained between dose to the pelvic lymphatic chains and their historical ICRU-38 surrogate points during HDR brachytherapy of locally advanced cervical cancer patients with 60Co tandem-ovoid applicator sets. The correlation strength between point A and prescription dose highly depends on the CTVHR volume.
Collapse
|
8
|
The impact of pelvic radiotherapy on the gut microbiome and its role in radiation-induced diarrhoea: a systematic review. Radiat Oncol 2021; 16:187. [PMID: 34563216 PMCID: PMC8466721 DOI: 10.1186/s13014-021-01899-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 08/28/2021] [Indexed: 02/08/2023] Open
Abstract
Pelvic radiotherapy is the key treatment for pelvic malignancies, usually including pelvic primary tumour lesions and lymphatic drainage areas in the pelvic region. Therefore, the intestinal tract in the radiation field is inevitably damaged, a phenomenon clinically referred to as radiation enteritis, and diarrhoea is the most common clinical symptom of radiation enteritis. Therefore, it is necessary to study the mechanism of radiation-induced diarrhoea. It has been found that the gut microbiome plays an important role in the development of diarrhoea in response to pelvic radiotherapy, and the species and distribution of intestinal microbiota are significantly altered in patients after pelvic radiotherapy. In this study, we searched for articles indexed in the Cochrane Library, Web of Science, EMBASE and PubMed databases in English and CNKI, Wanfang data and SINOMED in Chinese from their inception dates through 13 March 2020 to collect studies on the gut microbiome in pelvic radiotherapy patients. Eventually, we included eight studies: one study report on prostatic carcinoma, five studies on gynaecological carcinoma and two papers on pelvic carcinomas. All studies were designed as self-controlled studies, except for one that compared toxicity to nontoxicity. The results from all the studies showed that the diversity of intestinal flora decreased during and after pelvic radiotherapy, and the diversity of intestinal flora decreased significantly in patients with diarrhoea after radiotherapy. Five studies observed that the community composition of the gut microbiota changed at the phylum, order or genus level before, during, and after pelvic radiotherapy at different time points. In addition, the composition of the gut microbiota before radiotherapy was different between patients with postradiotherapy diarrhoea and those without diarrhoea in five studies. However, relevant studies have not reached consistent results regarding the changes in microbiota composition. Changes in the intestinal flora induced by pelvic radiotherapy and their relationship between changes in intestinal flora and the occurrence of radiation-induced diarrhoea (RID) are discussed in this study, providing a theoretical basis for the causes of RID after pelvic radiotherapy.
Collapse
|
9
|
Dosimetric impact of rotational setup errors in volumetric modulated arc therapy for postoperative cervical cancer. JOURNAL OF RADIATION RESEARCH 2021; 62:688-698. [PMID: 34056648 PMCID: PMC8273806 DOI: 10.1093/jrr/rrab044] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 03/19/2021] [Indexed: 06/12/2023]
Abstract
We aimed to evaluate the impact of rotational setup errors on the doses received during postoperative volumetric-modulated arc therapy (VMAT) for cervical cancer. Overall, 121 cone-beam computed tomography (CBCT) sets from 20 patients were rigidly registered to reference computed tomography (CT) sets based on bony landmarks. The rotational setup errors (pitch, yaw and roll) were calculated. Then, 121 CT sets involving rotational setup errors were created, and the dose distribution in these CT sets were recalculated. The recalculated dosimetric parameters for the clinical target volume (CTV) and organs at risk (OAR) were compared to the reference values, and the correlation coefficients between the dosimetric parameter differences and rotational setup errors were calculated. Only the pitch setup error was moderately correlated with CTV coverage (r ≥ 0.40) and strongly correlated with V45 for the bladder (r ≥ 0.91) and V40 for the rectum, small bowel and bone marrow (r ≥ 0.91). The maximum dosimetric difference in a single fraction and overall fractions was -1.59% and -0.69% in D98 for the CTV, 11.72% and 5.17% in V45 for the bladder and -8.03% and -4.68% in V40 for the rectum, respectively. In conclusion, rotational setup errors only slightly impact dose coverage during postoperative cervical cancer VMAT. However, the pitch setup error occasionally affected the doses received by the bladder or the rectum in the overall fraction when the error was systematic. Thus, rotational setup errors should be corrected by adjusting six-degree-of-freedom (DOF) couches to reduce dosimetric differences in the OARs.
Collapse
|
10
|
Abstract
Purpose This is a report of our initial experience using computed tomography (CT)-guided interstitial high dose rate (HDR) brachytherapy to treat bulky pelvic nodal metastases as a part of definitive radiotherapy. Material and methods Between February 2015 and April 2019, 14 cervical/endometrial cancer patients presenting with bulky pelvic node(s) underwent nodal interstitial brachytherapy boost in our institution. In total, 17 nodes were treated. The median maximum diameters of the positive nodes at the time of diagnosis and at the first nodal implant were 25 mm (range: 10-65 mm) and 16 mm (range: 9-51 mm), respectively. Dosimetry data of the lymph nodal target volume and small bowel were collected and compared using the paired-sample t-test. Treatment-related toxicities were classified using the Common Terminology Criteria for Adverse Events version 4.0. Results The median follow-up time for all patients was 26 months. Local recurrence in pelvic nodes occurred in one patient (7%) after 16 months. One patient experienced grade 3 bladder bleeding, and one patient experienced grade 2 pubic bone fracture. No patient had grade 2 or greater gastrointestinal toxicity. In the dosimetric analysis, the mean nodal brachytherapy D90% in terms of the total equivalent dose of 2 Gy (EQD2) was 65.6 Gyαβ10. The mean small bowel dose (SBD)0.1cc and SBD1cc in terms of the total EQD2 were 60.4 and 56.5 Gyαβ3, respectively. Nodal D90% was significantly higher in terms of the total EQD2 than the SBD0.1cc (p = 0.003) and SBD1cc (p < 0.001). The Kaplan-Meier 2-year pelvic control estimate was 90%. Conclusions CT-guided interstitial HDR pelvic nodal brachytherapy appears to be well tolerated with excellent local control in cervical or endometrial cancer patients with bulky pelvic nodes. This approach may offer a useful therapeutic option for unresected bulky pelvic nodes.
Collapse
|
11
|
Dosimetric predictors of nephrotoxicity in patients receiving extended-field radiation therapy for gynecologic cancer. Radiat Oncol 2021; 16:25. [PMID: 33541379 PMCID: PMC7863447 DOI: 10.1186/s13014-021-01755-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 01/28/2021] [Indexed: 11/10/2022] Open
Abstract
Purpose We sought dosimetric predictors of a decreasing estimated glomerular filtration rate (eGFR) in gynecological oncology patients receiving extended-field radiation therapy (EFRT). Materials and methods Between July 2012 and April 2020, 98 consecutive cervical or endometrial cancer patients underwent EFRT or whole-pelvis radiation therapy (WPRT) with concurrent cisplatin chemotherapy in our institution. To explore the effect of concurrent cisplatin chemotherapy on renal function, the renal function of the WPRT patients was examined. Of the 98 patients, 34 cervical or endometrial cancer patients underwent EFRT including extended-field intensity-modulated radiation therapy (EF-IMRT) and 64 cervical cancer patients underwent WPRT with cisplatin. Of the 34 EFRT patients, 32 underwent concurrent cisplatin chemotherapy. Excluding patients exhibiting recurrences within 6 months, 31 EFRT patients were analyzed in terms of the dose-volume kidney histograms (the percentages of kidney volumes receiving 12, 16, 20, and 24 Gy) and the post- to pre-treatment eGFR ratios. We calculated Pearson correlation coefficients between the renal dose volume and the percentage eGFR reductions of the 31 EFRT patients, and those treated via EF-IMRT. Renal dose constraint significance was evaluated using the Mann–Whitney U test. Results The eGFR value after WPRT with cisplatin remained largely unchanged for 12 months, unlike that after EFRT. In EFRT patients, a strong correlation was evident between the KV20Gy dose and the post- to pre-treatment eGFR ratio (correlation coefficients − 0.80 for all patients and − 0.74 for EF-IMRT patients). In EF-IMRT patients, the kidney volume receiving 20 Gy tended to correlate negatively with the eGFR reduction. The Mann–Whitney U test showed that patients with KV20Gy values < 10% retained significantly better renal function than did patients with KV20Gy values > 10% (P = 0.002). Conclusions Imposition of a severe kidney dose constraint during EF-IMRT may reduce nephrotic toxicity. Future prospective investigations of kidney-sparing EF-IMRT are required.
Collapse
|
12
|
Trajectory log analysis and cone-beam CT-based daily dose calculation to investigate the dosimetric accuracy of intensity-modulated radiotherapy for gynecologic cancer. J Appl Clin Med Phys 2021; 22:108-117. [PMID: 33426810 PMCID: PMC7882102 DOI: 10.1002/acm2.13163] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 11/13/2020] [Accepted: 12/15/2020] [Indexed: 11/21/2022] Open
Abstract
This study evaluated unexpected dosimetric errors caused by machine control accuracy, patient setup errors, and patient weight changes/internal organ deformations. Trajectory log files for 13 gynecologic plans with seven‐ or nine‐beam dynamic multileaf collimator (MLC) intensity‐modulated radiation therapy (IMRT), and differences between expected and actual MLC positions and MUs were evaluated. Effects of patient setup errors on dosimetry were estimated by in‐house software. To simulate residual patient setup errors after image‐guided patient repositioning, planned dose distributions were recalculated (blurred dose) after the positions were randomly moved in three dimensions 0–2 mm (translation) and 0°–2° (rotation) 28 times per patient. Differences between planned and blurred doses in the clinical target volume (CTV) D98% and D2% were evaluated. Daily delivered doses were calculated from cone‐beam computed tomography by the Hounsfield unit‐to‐density conversion method. Fractional and accumulated dose differences between original plans and actual delivery were evaluated by CTV D98% and D2%. The significance of accumulated doses was tested by the paired t test. Trajectory log file analysis showed that MLC positional errors were −0.01 ± 0.02 mm and MU delivery errors were 0.10 ± 0.10 MU. Differences in CTV D98% and D2% were <0.5% for simulated patient setup errors. Differences in CTV D98% and D2% were 2.4% or less between the fractional planned and delivered doses, but were 1.7% or less for the accumulated dose. Dosimetric errors were primarily caused by patient weight changes and internal organ deformation in gynecologic radiation therapy.
Collapse
|
13
|
Plan-Optimization Method for Central-shielding Pelvic Volumetric-modulated Arc Therapy for Cervical Cancer. In Vivo 2020; 34:3611-3618. [PMID: 33144475 DOI: 10.21873/invivo.12206] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 09/10/2020] [Accepted: 09/14/2020] [Indexed: 11/10/2022]
Abstract
AIM To establish a method of plan optimization in pelvic volumetric-modulated arc therapy (VMAT) for cervical cancer using the central-shielding (CS) principle. PATIENTS AND METHODS We created external beam VMAT plans for eight cases with non-bulky stage I-IIb using the CS principle based on the Japanese standard guideline. Clinical target volumes (CTVs) for whole-pelvis (WP) irradiation were created using published guidelines, and CTVs for CS irradiation were created by subtracting the uterus corpus and 4 cm-wide regions centered at the cervix and vagina from the CTVs for WP irradiation. For plan optimization of CS irradiation, a 4-cm diameter cylindrical volume centered in the cervix and vagina was created as the volume receiving a high dose in brachytherapy, and the volume overlapping with the rectum was defined as the Ant-Rectum. Dose-volume histogram (DVH) parameters of two CS VMAT plans with and without (VMATOPT/VMATNO) dose optimization to the Ant-Rectum were compared. RESULTS VMATOPT plans resulted in significantly lower DVH parameters of the Ant-Rectum and rectum compared to VMATNO plans. These were comparable to the DVH parameters of three-dimensional conformal radiotherapy (3DCRT) plans. Both VMAT plans resulted in significantly better coverage of planning target volumes than did the 3DCRT plans. CONCLUSION In the implementation of IMRT/VMAT as the standard treatment for cervical cancer in Japan, our optimization method may be an essential step toward fully benefitting from the CS principle.
Collapse
|
14
|
Pelvic bone marrow sparing intensity modulated radiotherapy reduces the incidence of the hematologic toxicity of patients with cervical cancer receiving concurrent chemoradiotherapy: a single-center prospective randomized controlled trial. Radiat Oncol 2020; 15:180. [PMID: 32727497 PMCID: PMC7389381 DOI: 10.1186/s13014-020-01606-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Accepted: 06/30/2020] [Indexed: 12/02/2022] Open
Abstract
Purpose To test the efficacy and feasibility of pelvic bone marrow sparing intensity modulated radiotherapy (PBMS-IMRT) in reducing grade 2 or higher hematological toxicity (HT2+) for patients with cervical cancer treated with concurrent chemoradiotherapy. Methods and materials A total of 164 patients with Stage Ib2–IIIb cervical cancer were prospectively enrolled from March 2018 to March 2019 at a single center and were randomly allocated into the PBMS group or the control group. The control group received weekly cisplatin concurrently with IMRT, followed by intracavitary brachytherapy. The PBMS group additionally received PBM dose constraint. The dosimetric parameters of the pelvic bone (PB) and the subsites including hip bone (HIP) and lumbosacral spine (LSS) and the corresponding bone marrow were recorded. The endpoint of the trial was acute hematologic or gastrointestinal toxicity. Receiver operating characteristic curves were used to derive optimal dosimetric planning constraints. Results Eighty-two patients in the PBMS group and 82 in the control group were enrolled for statistical analysis. The incidence of HT2+ in the PBMS group was 50.0%, significantly lower than the 69.5% incidence in the control group (P = 0.02). Patients with PB V40 ≥ 28% were more likely to experience HT2+ (OR = 2.85, P = 0.006), while the incidence of grade 2 or higher gastrointestinal toxicity (GT2+) events did not differ significantly between the two groups (P > 0.05). Dosimetric parameters of LSS showed stronger associations with HT2+ than other subsites. The patients with LSS V10 ≥ 87% and LSS mean ≥ 39 Gy were more likely to experience HT2+ (OR = 3.13, P = 0.001;OR = 3.03, P = 0.002, respectively). Conclusion PBMS-IMRT reduced HT compared with IMRT alone. Efforts to maintain LSS V10 < 87%, LSS mean < 39 Gy and PB V40 < 28% simultaneously may reduce the risk of HT2 +. Trial registration The trial was registered with Chinese clinical trial registry (ChiCTR1800015069).
Collapse
|
15
|
Implementing an online radiotherapy quality assurance programme with supporting continuous medical education – report from the EMBRACE-II evaluation of cervix cancer IMRT contouring. Radiother Oncol 2020; 147:22-29. [DOI: 10.1016/j.radonc.2020.02.017] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2019] [Revised: 02/20/2020] [Accepted: 02/20/2020] [Indexed: 12/30/2022]
|
16
|
Clinical experience of pelvic radiotherapy or chemoradiotherapy for postoperative uterine cervical cancer using intensity-modulated radiation therapy. JOURNAL OF RADIATION RESEARCH 2020; 61:470-478. [PMID: 32100833 PMCID: PMC7299262 DOI: 10.1093/jrr/rraa004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 01/13/2020] [Accepted: 02/11/2020] [Indexed: 06/10/2023]
Abstract
The purpose of this study was to reveal treatment outcomes and toxicity after pelvic intensity-modulated radiotherapy (IMRT) for postoperative uterine cervical cancer of Japanese patients. Consecutive patients who were treated with pelvic IMRT for postoperative cervical cancer in our institute were retrospectively analyzed. Relapse-free survival (RFS) and overall survival (OS) were calculated using the Kaplan-Meier estimator, and log-rank tests were used to compare differences. From the database, 62 patients were identified. The pathology was squamous cell carcinoma in 44 patients and other pathology in 18 patients. Of the 62 patients, 35 had high-risk prognostic factors and 27 patients had intermediate-risk prognostic factors. The prescribed radiation doses were 50 Gy in 25 fractions for 58 patients and 50.4 Gy in 28 fractions for 4 patients. One patient received a vaginal cuff boost. Chemotherapy was administered in 36 patients. During the median follow-up period of 50.9 months, there was no locoregional failure. Six patients in the high-risk group relapsed, but none of the patients in the intermediate-risk group relapsed (P = 0.02). The 3-year OS and RFS rates were 98.2% and 90.9%, respectively. Significant factors related to RFS were squamous cell carcinoma pathology (P = 0.02), pathological T stage (P = 0.04), surgical margin status (P < 0.01) and multiple lymph nodes metastases (P < 0.01). Grade 3 or more toxicity occurred in 6 patients. Four patients had obstruction of the intestine, and 2 patients had stenosis of the urinary tract. In clinical practice, the use of pelvic IMRT for postoperative cervical cancer of Japanese patients showed a low rate of toxicity without decreasing the efficacy.
Collapse
|
17
|
Efficacy of herbal medicine TJ-14 for acute radiation-induced enteritis: a multi-institutional prospective Phase II trial. JOURNAL OF RADIATION RESEARCH 2020; 61:140-145. [PMID: 31691810 PMCID: PMC7022136 DOI: 10.1093/jrr/rrz025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 03/29/2019] [Indexed: 05/11/2023]
Abstract
The purpose of this multi-institutional Phase II trial study was to prospectively investigate the efficacy of the herbal medicine TJ-14 for acute radiation-induced enteritis (ARE). TJ-14 was administered orally as a first-line treatment for ARE. The primary end point was efficacy at 1 week. The secondary end points were: (i) the efficacy of TJ-14 at 2 and 3 weeks after its administration, (ii) the quality of life score (FACT-G) at 1, 2 and 3 weeks after its administration, and (iii) adverse events. If the efficacy of TJ-14 was observed in eight patients or fewer, its efficacy was rejected. Results: Forty patients receiving pelvic radiotherapy were enrolled. Of these, 22 developed ARE and received TJ-14. Among these, 19 had cervical cancer and 9 received chemoradiotherapy. TJ-14 efficacy was shown in 19 out of the 22 patients (86%). Stool frequency per day at 1 week significantly decreased (mean ± SD: 4.9 ± 2.1 vs 3.7 ± 1.9, P = 0.02). This effect continued at 2 (2.2 ± 1.4, P = 0.004) and 3 weeks (2.1 ± 0.9, P = 0.05). Thirteen out of the 22 patients (59%) continued TJ-14 until the end of radiotherapy. FACT-G score deterioration was not observed after the administration of TJ-14. Grade 1 hypokalemia was observed in 4 patients, and Grade 1 constipation in 3. We concluded that TJ-14 is sufficiently promising to be examined in a Phase III trial. A randomized controlled trial is currently being planned.
Collapse
|
18
|
Clinical Evaluation of Onrad, A New Low-cost Version of TomoTherapy that Uses Only Static Beams. Kurume Med J 2020; 65:129-136. [PMID: 31723077 DOI: 10.2739/kurumemedj.ms654004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE This study evaluated the clinical feasibility of a new low-cost TomoTherapy system (OnradTM) and compared it with low-cost linear accelerator models (linacs). METHODS Various aspects of treatment and cost were compared between Onrad and linacs for 3-dimensional radiotherapy (3DCRT). Dosimetric comparisons of 10 patients each with breast, stage III lung, prostate, head and neck, and cervical cancers were carried out (total 100 plans). RESULTS Onrad had advantages in terms of availability of long treatment fields and a smaller mechanical footprint. For breast cancers and lung cancers, target dose homogeneity in Onrad plans was better than that in 3DCRT. In the prostate plans, Onrad plans provided superior D95, conformity and homogeneity. The rectum doses of Onrad plans were lower than those with 3DCRT. Onrad plans provided superior homogeneity and D95 in head and neck cancer. The mean dose and V10-40 Gy of the parotid glands was lower using Onrad. In the cervical cancer plans, target doses were similar with both systems. Normal tissue doses were equal. CONCLUSIONS Onrad is useful in the clinical setting. Onrad can achieve favorable or comparable dose distributions compared with those of 3DCRT in actual clinical treatment of breast, lung, prostate, head and neck, and cervical cancers.
Collapse
|
19
|
Definitive radiotherapy consisting of whole pelvic radiotherapy with no central shielding and CT-based intracavitary brachytherapy for cervical cancer: feasibility, toxicity, and oncologic outcomes in Japanese patients. Int J Clin Oncol 2020; 25:1977-1984. [PMID: 32852648 PMCID: PMC7572338 DOI: 10.1007/s10147-020-01736-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Accepted: 06/23/2020] [Indexed: 10/31/2022]
Abstract
BACKGROUND This prospective study investigated the feasibility, toxicity, and oncologic outcomes of definitive radiotherapy (RT) consisting of whole pelvic radiotherapy with no central shielding (noCS-WPRT) and CT-based intracavitary brachytherapy (ICBT) in Japanese patients with cervical cancer. METHODS Patients with cervical cancer of FIGO stages IB1-IVA were eligible. The treatment protocol consisted of noCS-WPRT of 45 Gy in 25 fractions and CT-based high dose-rate ICBT of 15 or 20 Gy in 3 or 4 fractions prescribed at point A. The prescribed ICBT dose was decreased if the manual dwell time/position optimization failed to meet organs-at-risk constraints. Graphical optimization and additional interstitial needles were not applied. RESULTS We enrolled 40 patients. FIGO stages were IB1: 11, IB2: 13, IIA2: 1, IIB: 11, IIIB: 3, and IVA: 1. Median (range) pretreatment tumor diameter was 47 (14-81) mm. Point A doses were decreased in 19 of 153 ICBT sessions (12%). The median follow-up duration was 33 months. The 2-year rates of pelvic control, local control (LC), and progression-free survival were 83%, 85%, and 75%, respectively. Pre-ICBT tumor diameter, high-risk clinical target volume (HR-CTV), total HR-CTV D90, and overall treatment time (OTT) significantly affected LC. Late adverse events (grade ≥ 3) were observed in 3 patients (2 in the bladder, 1 in the rectum). CONCLUSIONS Definitive RT consisting of noCS-WPRT and CT-based ICBT was feasible for Japanese patients with cervical cancer. To further improve LC, additional interstitial needles for patients with a large HR-CTV and shorter OTT should be considered.
Collapse
|
20
|
Determining the recommended dose of stereotactic body radiotherapy boost in patients with cervical cancer who are unsuitable for intracavitary brachytherapy: a phase I dose-escalation study. Jpn J Clin Oncol 2019; 49:856-861. [PMID: 31112278 DOI: 10.1093/jjco/hyz074] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Revised: 04/25/2019] [Accepted: 05/07/2019] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVE Some patients are ineligible for intracavitary brachytherapy (ICBT) for locally advanced cervical cancer. Stereotactic body radiotherapy (SBRT) could be a good treatment option for such patients. This phase I clinical trial aimed to determine the recommended SBRT boost dose for ICBT-ineligible cervical cancer patients. METHODS Patients with untreated uterine cervical cancer (clinical stages IB1-IIIB) who were ineligible for ICBT were enrolled. Radiotherapy consisted of whole-pelvis radiotherapy (45 Gy in 25 fractions) followed by SBRT. Three dose levels of SBRT (19.5/21/22.5 Gy in three fractions) were set; the treatment protocol began at 21 Gy (level 2). The 'rolling-six' design study was used to establish the recommended dose of SBRT. Each dose level covered three or six patients. The primary endpoint included dose-limiting toxicity (DLT), defined as the occurrence of grade 3 (or worse) non-hematologic adverse effects within 6 months after SBRT. RESULTS The median follow-up after registration was 17 (range, 8-32) months. Three patients were enrolled in study level 2 (SBRT of 21 Gy); none of the patients exhibited DLT within 6 months after treatment completion. In study level 3 (SBRT of 22.5 Gy), three patients did not exhibit DLT. Although all six patients achieved locoregional control during follow-up, one patient treated with level 2 SBRT experienced distant metastases 14 months after registration. CONCLUSIONS The recommended dose of SBRT boost was 22.5 Gy in three fractions. We plan to conduct a phase II multi-center clinical trial using the methodology obtained from the current study.
Collapse
|
21
|
Postoperative pelvic intensity-modulated radiation therapy reduced the incidence of late gastrointestinal complications for uterine cervical cancer patients. JOURNAL OF RADIATION RESEARCH 2019; 60:650-657. [PMID: 31251358 PMCID: PMC6805982 DOI: 10.1093/jrr/rrz041] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 04/21/2019] [Indexed: 06/09/2023]
Abstract
The aim of the study was to compare incidences of late gastrointestinal adverse events and clinical outcomes between 3D conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) after radical hysterectomy for cervical cancer patients. Between March 2007 and May 2014, 73 cervical cancer patients with high-risk prognostic factors (pelvic lymph node metastasis and/or parametrial invasion) underwent postoperative pelvic radiation therapy (RT) after radical hysterectomy. Of these patients, 33 (45%) and 40 (55%) received 3DCRT and IMRT, respectively. Because the gastrointestinal obstruction rate after postoperative pelvic 3DCRT was high, no concurrent chemotherapy was applied until 2015. The median follow-up period for patients with 3DCRT and IMRT was 82 months (6-113) and 50 months (5-74), respectively. There was no significant difference in overall survival (OS) (4-year OS: 85% vs 78%, P = 0.744) or disease-free survival (DFS) (4-year DFS: 73% vs 64%, P = 0.696) between the two groups. Eleven (33%) and 13 (33%) patients experienced recurrence after 3DCRT and IMRT, respectively. The patients who had vaginal invasion from the postoperative pathological finding more frequently had loco-regional recurrence than the patients who did not have vaginal invasion (2.3% vs 17%, P = 0.033). Gastrointestinal obstruction was observed in 9 (27%) and 3 (7.5%) patients for 3DCRT and for IMRT, respectively (P = 0.026). Severe gastrointestinal obstruction that required surgery was observed in 6 (19%) patients, all of whom received adjuvant RT by 3DCRT. IMRT could reduce the incidence of late severe gastrointestinal obstruction after postoperative pelvic RT with a non-inferior clinical efficacy compared with 3DCRT.
Collapse
|
22
|
Single-arm confirmatory trial of postoperative concurrent chemoradiotherapy using intensity modulated radiation therapy for patients with high-risk uterine cervical cancer: Japan Clinical Oncology Group study (JCOG1402). Jpn J Clin Oncol 2019; 49:881-885. [PMID: 31613355 DOI: 10.1093/jjco/hyz098] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 05/14/2019] [Accepted: 06/12/2019] [Indexed: 11/12/2022] Open
Abstract
A single-arm multi-center confirmatory trial was started in Japan to confirm the efficacy and safety of post-radical hysterectomy concurrent chemoradiotherapy using intensity-modulated radiation therapy (IMRT-CCRT) for patients with high-risk uterine cervical cancer, for which the current standard treatment is CCRT using three-dimensional conformal radiation therapy (3DCRT-CCRT). This study began in April 2017 and a total of 220 patients will be accrued from 44 institutions within 3.5 years. The primary endpoint is 3-year relapse-free survival. The secondary endpoints are overall survival, loco-regional relapse-free survival, proportion of late lower gastrointestinal adverse events greater than or equal to grade 3, proportion of lower edema limbs, adverse events, and serious adverse events. This trial was registered at the Japan Registry of Clinical Trials as jRCTs031180194 (https://jrct.niph.go.jp/).
Collapse
|
23
|
Dummy-run for standardizing plan quality of intensity-modulated radiotherapy for postoperative uterine cervical cancer: Japan Clinical Oncology Group study (JCOG1402). Radiat Oncol 2019; 14:133. [PMID: 31358026 PMCID: PMC6664568 DOI: 10.1186/s13014-019-1340-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Accepted: 07/18/2019] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND The purpose of this study was to assess compliance with treatment planning in a dummy-run for a multicenter clinical trial involving patients with high-risk postoperative uterine cervical cancer using intensity-modulated radiation therapy (IMRT) (JCOG1402 trial). METHODS For the dummy-run, we prepared a computed tomography dataset comprising two anonymized cases of post-hysterectomy cervical cancer. These were sent to the 47 participating institutions to assess institutional plan quality such as delineations and dose distributions. RESULTS Central review showed 3 and 4 deviations per treatment plan on average. The deviations related to the nodal and vaginal cuff clinical target volume (CTV) delineation, which accounted for approximately 50% of the total deviations. The CTV vaginal cuff showed considerable differences in delineation compared with the nodal CTV. For the Dice similarity coefficient, case 1 showed a mean ± 1σ of 0.81 ± 0.03 and 0.60 ± 0.09 for the nodal and the CTV vaginal cuff, respectively, while these were 0.81 ± 0.04 and 0.54 ± 0.14, respectively, for case two. Of the 47 institutions, 10 were required to resubmit their treatment plan because the delineations, planning target volume margin, and required dose distributions were not in accordance with the JCOG1402 protocol. CONCLUSIONS The dummy-run test in postoperative uterine cervical cancer demonstrated substantial deviations in the delineations, particularly for the CTV vaginal cuff. The analysis data could provide helpful information on delineation and planning, allowing standardization of IMRT planning for postoperative uterine cervical cancer. TRIAL REGISTRATION Japanese Clinical Trial Registry #: UMIN000027017 at https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000030672;language=J.
Collapse
|
24
|
Assessment of the anatomical position of point B and the relationship between point B dose and the dose delivered to pelvic lymph nodes in CT-based high-dose-rate brachytherapy for uterine cervical cancer. J Contemp Brachytherapy 2019; 11:137-145. [PMID: 31139222 PMCID: PMC6536146 DOI: 10.5114/jcb.2019.84419] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Accepted: 02/20/2019] [Indexed: 11/17/2022] Open
Abstract
Purpose To examine the anatomical position of point B and the relationship between the dose at point B and the dose delivered to the pelvic lymph nodes in computed tomography (CT)-based brachytherapy for cervical cancer. Material and methods Forty-nine cervical cancer patients were treated at Kyushu University Hospital. For all cases, planning CT images obtained after the applicator insertion were imported to an Oncentra Brachy (Elekta AB, Stockholm, Sweden), and points A (dose prescription, 6 Gy) and points B were set according to the Manchester method. The pelvic lymph node regions (external iliac, internal iliac, and obturator) were contoured, and the anatomic positions of 98 points B in 49 patients were examined. Dose volume histogram (DVH) parameters (D100, D90, D50, D2cc, D1cc, and D0.1cc) were calculated for each lymph node region and compared with the point B dose. Results The mean bilateral dose to point B was 1.70 ±0.18 Gy, and 26 (27%) of 98 points B were not located in any pelvic lymph node regions. The DVH analysis indicated a low degree of correlation overall, and all values were significantly different from point B doses (p < 0.05), except for D0.1cc of the external iliac node (p = 0.0594) and D1cc of the internal iliac node (p = 0.0711). Conclusions We investigated the anatomical location of point B in patients with cervical cancer who underwent brachytherapy, and the DVH analysis revealed that the point B dose was a poor surrogate for the dose delivered to the pelvic lymph nodes.
Collapse
|
25
|
Japan Society of Gynecologic Oncology guidelines 2017 for the treatment of uterine cervical cancer. Int J Clin Oncol 2018; 24:1-19. [DOI: 10.1007/s10147-018-1351-y] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 09/30/2018] [Indexed: 10/28/2022]
|
26
|
Dosimetric comparison of three-dimensional conformal radiotherapy versus volumetric-arc radiotherapy in cervical cancer treatment: applying the central-shielding principle to modern technology. JOURNAL OF RADIATION RESEARCH 2018; 59:639-648. [PMID: 30053184 PMCID: PMC6151642 DOI: 10.1093/jrr/rry054] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Indexed: 05/05/2023]
Abstract
This study evaluated the feasibility of applying volumetric-arc radiotherapy (VMAT) in standard curative radiotherapy for non-bulky cervical cancer using the central-shielding principle. Whole-pelvis irradiation of 20 Gy and central-shielding pelvis irradiation of 30 Gy, both in 2 Gy fractions, were created using 3D conformal radiotherapy (3DCRT) with a standard midline block or VMAT. Composite dose distributions and DVH parameters were compared first in a simple phantom model and then in 10 clinical cases of Stage I-II cervical cancer. Whole-pelvis clinical target volumes (CTVs) were created from published guidelines for primary disease and lymph node regions, and CTVs for central-shielding irradiation were created by subtracting uterus corpus and 4 cm-wide regions centered at the cervical canal and vagina. In a phantom model, VMAT provided adequate dose coverage to the PTVs without excessive doses to the rectum or bladder compared with the 3DCRT plan. In the clinical cases, VMAT plans resulted in slightly but significantly better coverage of PTVs. The DVH parameters for the rectum and bladder were equivalent or lower for VMAT plans compared with the 3DCRT plans. In the bowel, V30Gy, V40Gy, and V50Gy were significantly lower in VMAT plans compared with in the 3DCRT plans (47.6% vs 61.0%, 29.8% vs 56.2% and 6.8% vs 21.1%, respectively). Based on these results, VMAT may be used in external-beam radiotherapy for early-stage cervical cancer by adopting the principle of central-shielding pelvis irradiation. Furthermore, VMAT is likely to reduce doses to the small bowel and may reduce gastrointestinal toxicities for these patients.
Collapse
|
27
|
Reply to 'Addressing the challenge of proper delineation of lymph node stations in modern radiotherapy for lung cancer'. JOURNAL OF RADIATION RESEARCH 2018; 59:524-525. [PMID: 29788492 PMCID: PMC6054163 DOI: 10.1093/jrr/rry040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 04/09/2018] [Indexed: 06/08/2023]
|
28
|
Positional uncertainty of vaginal cuff and feasibility of implementing portable bladder scanner in postoperative cervical cancer patients. Phys Med 2018; 45:1-5. [PMID: 29472073 DOI: 10.1016/j.ejmp.2017.11.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 11/23/2017] [Accepted: 11/24/2017] [Indexed: 12/30/2022] Open
Abstract
PURPOSE To propose a geometrical margin for definition of the vaginal cuff PTV using only CT images of the full bladder (CTfull) in postoperative cervical cancer patients. METHODS Twenty-nine operated cervical cancer patients underwent volumetric arc therapy with a bladder filling protocol. This study assessed bladder filling using a portable bladder scanner and cone-beam computed tomography (CBCT) during the entire treatment period. The measured bladder volumes with a BladderScan® were compared with the delineated volume on CBCT. Titanium clips in the vaginal cuff were analysed to assess geometrical uncertainty and the influence of rectal and bladder volume changes. RESULTS BladderScan® showed good agreement with the delineated volume (R = 0.80). The volume changes in the bladder have a greater influence on the clip displacements than in the rectum. The 95th percentile of uncertainty of the clips in reference to CTfull in the right-left (RL), the superoinferior (SI), and the anteroposterior (AP) was 0.32, 0.65, and 1.15 cm, respectively. From this result and intra-fractional movements of the vaginal cuff reported by Haripotepornkul, a new geometrical margin was proposed for definition of the vaginal cuff planning target volume (PTV): 0.5, 0.9, and 1.4 cm in the RL, SI, and AP directions, respectively. CONCLUSIONS A new geometrical margin was proposed for definition of the vaginal cuff PTV based on CTfull, which will be needless of empty bladder at the planning CT scan. This method allows patients to reduce the burden and efficient routine CT scans can be improved.
Collapse
|
29
|
Strategies for reducing ovarian dose in volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer. Br J Radiol 2017; 91:20160777. [PMID: 29072492 DOI: 10.1259/bjr.20160777] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To reduce the ovarian dose with volumetric modulated arc therapy (VMAT), an original VMAT was designed with two types of arcs to restrict angles and fields (R-VMAT). METHODS The subjects were 11 patients who underwent ovarian transposition with clips left by a surgeon. Three methods, intensity-modulated radiotherapy (IMRT), standard VMAT (S-VMAT) and R-VMAT, were optimized for assessment of the ovarian dose with the target coverage kept high. RESULTS The homogeneity and conformity indexes for the planning target volume (PTV) were similar for the three methods. However, the average ± SD of the ovarian mean dose (OMD) was 5.0 ± 1.5, 4.9 ± 1.9 and 3.5 ± 1.4 Gy, and the percentage of ovarian volume exceeding 5 Gy (V5) was 41.5 ± 34.1%, 34.1 ± 38.05% and 8.4 ± 20.5% for IMRT, S-VMAT and R-VMAT, respectively. The OMD and V5 were significantly smaller for R-VMAT than for the other plans (p < 0.01). Correlation values between the OMD and the lateral distance from the ovaries to the PTV surface were 0.86, 0.81 and 0.82 for IMRT, S-VMAT and R-VMAT, respectively. CONCLUSION These findings suggest that R-VMAT delivered the lowest dose to the ovaries. To reduce the OMD to less than 3 Gy, ovaries should be transposed laterally 6.1 cm away from the PTV surface when R-VMAT is used. Advances in knowledge: When organs with high susceptibility to radiation, such as ovaries, are near the PTV, R-VMAT is superior to IMRT and S-VMAT.
Collapse
|
30
|
Delineating the relationship between Point A prescription dose and pelvic lymph node doses in intracavitary high-dose-rate brachytherapy treatment of cervical cancer for use in low- and middle-income countries. Brachytherapy 2017; 17:201-207. [PMID: 29066085 DOI: 10.1016/j.brachy.2017.09.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Revised: 09/01/2017] [Accepted: 09/05/2017] [Indexed: 11/19/2022]
Abstract
PURPOSE To define the relationship between the Point A prescription dose and the dose delivered to various pelvic lymph node groups during high-dose-rate (HDR) brachytherapy treatment of cervical cancer. In less developed countries, brachytherapy is often done without three-dimensional image guidance, instead relying on plain radiography and prescription to Point A. A defined relationship between Point A dose and lymph node doses would help physicians in these health care settings to more accurately estimate nodal doses. METHODS AND MATERIALS Treatment data from 50 fractions of HDR brachytherapy of cervical cancer were reviewed, the pelvic lymph nodes were contoured, and dose-volume histogram parameters were obtained. Dose-volume histogram parameters for each contour were normalized as a percentage of the corresponding Point A dose. All nodal groups were divided into left and right sides, except the presacral nodal group. RESULTS AND CONCLUSIONS Mean Point A doses were bilateral (Bil) 5.92 Gy ± 0.58, left (L) 5.93 ± 0.59, and right (R) 5.92 ± 0.59. Mean normalized D90 values for the various lymph node groups were as follows-obturator: Bil 20.3% ± 4.5, L 20.5% ± 4.4, and R 20.2% ± 5.2; external iliac: Bil 9.5% ± 2.9, L 10.0% ± 3.1, and R 9.5% ± 3.0; internal iliac: Bil 12.2% ± 3.5, L 12.1% ± 3.4, and R 12.9% ± 4.7; common iliac: Bil 4.3% ± 1.6, L 4.3% ± 1.6, and R 4.3% ± 1.7; and presacral: 8.7% ± 3.4. These relationships can serve as a useful tool for evaluating lymph node doses during HDR brachytherapy of cervical cancer in facilities performing two-dimensional treatment planning and those with limited resources.
Collapse
|
31
|
Intensity-modulated radiotherapy combined with iodine-125 seed implantation in non-central recurrence of cervical cancer: A case report and literature review. Oncol Lett 2017; 14:4085-4091. [PMID: 28959365 PMCID: PMC5607647 DOI: 10.3892/ol.2017.6680] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2016] [Accepted: 03/03/2017] [Indexed: 12/22/2022] Open
Abstract
Recurrent cervical cancer is a clinically complex disease that is difficult to treat. There are numerous treatment options, but the results achieved by each are poor. External-beam radiation therapy of the pelvic lymph drainage area, in combination with intracavitary afterloading or the interstitial implantation of a radiation source (i.e., brachytherapy), are the current standard radiotherapy regimens used in high-risk clinical targets. However, there are few reports concerning the use of iodine-125 (125I) seed implantation brachytherapy in recurrent cervical cancer, and the effects of treatment and adverse reactions have not yet been systematically evaluated. In the present study one such case is reported, in which the patient was successfully treated with intensity-modulated radiotherapy (IMRT) in combination with 125I seed implantation. The patient, a 47-year-old woman, was initially diagnosed with International Federation of Gynecology and Obstetrics stage IB1 cervical cancer, and received a radical hysterectomy, left lateral adnexectomy and pelvic lymph node dissection. A follow-up examination 23 months later revealed vaginal invasion and a solitary lump in the cervical stump with a maximum diameter of 38 mm. The patient was subsequently diagnosed with recurrent cervical cancer and was treated with six cycles of docetaxel and nedaplatin chemotherapy, alongside IMRT and interstitial 125I seed implantation. At the point of manuscript submission, the patient's progression-free survival time was 33 months and long-term adverse reactions were acceptable. The response of this patient indicates that 125I seed implantation could be used as a complementary treatment for recurrent cervical cancer and may also prove to be a reliable means for the comprehensive treatment of primary cervical cancer, as the patient had characteristics similar to primary cervical cancer, although this hypothesis could not be confirmed in the present study.
Collapse
|
32
|
Abstract
Background and Purpose: Although there is a strong biological rationale to electively treat the pelvic nodes during bladder preservation, its clinical benefit is uncertain. This may be explained by the incidental dose received by the nodal regions when treating the bladder alone. This study was conducted to investigate the doses received by the different pelvic nodal regions when the bladder alone is treated by standard conformal radiotherapy. Methods and Materials: The computed tomography data sets of 20 patients with node-negative muscle-invasive bladder cancer treated in a bladder preservation protocol were studied. Patients were originally treated with conformal radiotherapy to the bladder alone. Replanning was done with additional delineation of the pelvic nodal regions namely common iliac (upper and lower), presacral, internal iliac, obturator, and external iliac. Dose volume parameters such as Dmean, Dmax, D100%, D66%, D33%, V40, and V50 to each of the nodal regions were estimated for all patients. Results: The obturator nodes received the highest dose among all nodal regions. The mean dose received by obturator, external iliac, and internal iliac regions was 59, 45, and 36 Gy, respectively. The dose received by these 3 regions in the full bladder state was 63, 52, and 47 Gy, respectively. The dose received by all other pelvic nodal regions was low and not clinically relevant. Conclusion: The incidental dose received by obturator and external iliac nodes is clinically significant in bladder-only radiation, possibly enough to influence micrometastatic disease. This may be a reason for the lack of clear benefit seen with nodal irradiation in bladder cancer. Advances in Knowledge: This study highlights that the incidental dose received by obturator and external iliac nodes is clinically significant in bladder-only radiation. The obturator nodes received the highest dose among all nodal regions with mean dose of 59 Gy.
Collapse
|
33
|
The Japan Lung Cancer Society-Japanese Society for Radiation Oncology consensus-based computed tomographic atlas for defining regional lymph node stations in radiotherapy for lung cancer. JOURNAL OF RADIATION RESEARCH 2017; 58:86-105. [PMID: 27609192 PMCID: PMC5321185 DOI: 10.1093/jrr/rrw076] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Revised: 05/31/2016] [Accepted: 06/01/2016] [Indexed: 05/02/2023]
Abstract
The purpose of this study was to develop a consensus-based computed tomographic (CT) atlas that defines lymph node stations in radiotherapy for lung cancer based on the lymph node map of the International Association for the Study of Lung Cancer (IASLC). A project group in the Japanese Radiation Oncology Study Group (JROSG) initially prepared a draft of the atlas in which lymph node Stations 1-11 were illustrated on axial CT images. Subsequently, a joint committee of the Japan Lung Cancer Society (JLCS) and the Japanese Society for Radiation Oncology (JASTRO) was formulated to revise this draft. The committee consisted of four radiation oncologists, four thoracic surgeons and three thoracic radiologists. The draft prepared by the JROSG project group was intensively reviewed and discussed at four meetings of the committee over several months. Finally, we proposed definitions for the regional lymph node stations and the consensus-based CT atlas. This atlas was approved by the Board of Directors of JLCS and JASTRO. This resulted in the first official CT atlas for defining regional lymph node stations in radiotherapy for lung cancer authorized by the JLCS and JASTRO. In conclusion, the JLCS-JASTRO consensus-based CT atlas, which conforms to the IASLC lymph node map, was established.
Collapse
|
34
|
Proposed definition of the vaginal cuff and paracolpium clinical target volume in postoperative uterine cervical cancer. Pract Radiat Oncol 2016; 6:5-11. [PMID: 26767622 DOI: 10.1016/j.prro.2015.04.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2015] [Revised: 04/15/2015] [Accepted: 04/20/2015] [Indexed: 11/24/2022]
Abstract
PURPOSE The aim of this study was to develop an appropriate definition for vaginal cuff and paracolpium clinical target volume (CTV) for postoperative intensity modulated radiation therapy in patients with uterine cervical cancer. METHODS AND MATERIALS A working subgroup was organized within the Radiation Therapy Study Group of the Japan Clinical Oncology Group to develop a definition for the postoperative vaginal cuff and paracolpium CTV in December 2013. The group consisted of 5 radiation oncologists who specialized in gynecologic oncology and a gynecologic oncologist. A comprehensive literature review that included anatomy, surgery, and imaging fields was performed and was followed by multiple discreet face-to-face discussions and e-mail messages before a final consensus was reached. RESULTS Definitions for the landmark structures in all directions that demarcate the vaginal cuff and paracolpium CTV were decided by consensus agreement of the working group. A table was created that showed boundary structures of the vaginal cuff and paracolpium CTV in each direction. CONCLUSIONS A definition of the postoperative cervical cancer vaginal cuff and paracolpium CTV was developed. It is expected that this definition guideline will serve as a template for future radiation therapy clinical trial protocols, especially protocols involving intensity modulated radiation therapy.
Collapse
|
35
|
The role of interstitial brachytherapy in the management of primary radiation therapy for uterine cervical cancer. J Contemp Brachytherapy 2016; 8:391-398. [PMID: 27895680 PMCID: PMC5116446 DOI: 10.5114/jcb.2016.62938] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2016] [Accepted: 08/07/2016] [Indexed: 11/17/2022] Open
Abstract
Purpose The aim of this study was to report the clinical results of uterine cervical cancer patients treated by primary radiation therapy including brachytherapy, and investigate the role of interstitial brachytherapy (ISBT). Material and methods All consecutive uterine cervical cancer patients who were treated by primary radiation therapy were reviewed, and those who were treated by ISBT were further investigated for clinical outcomes and related toxicities. Results From December 2008 to October 2014, 209 consecutive uterine cervical cancer patients were treated with primary radiation therapy. Among them, 142 and 42 patients were treated by intracavitary and hybrid brachytherapy, respectively. Twenty-five patients (12%) were treated by high-dose-rate (HDR)-ISBT. Five patients with distant metastasis other than para-aortic lymph node were excluded, and 20 patients consisted of the analysis. Three-year overall survival (OS), progression-free survival (PFS), and local control (LC) rate were 44.4%, 38.9%, and 87.8%, respectively. Distant metastasis was the most frequent site of first relapse after HDR-ISBT. One and four patients experienced grade 3 and 2 rectal bleeding, one grade 2 cystitis, and two grade 2 vaginal ulcer. Conclusions Feasibility and favorable local control of interstitial brachytherapy for locally advanced cervical cancer was demonstrated through a single institutional experience with a small number of patients.
Collapse
|
36
|
Whole-pelvic radiotherapy with spot-scanning proton beams for uterine cervical cancer: a planning study. JOURNAL OF RADIATION RESEARCH 2016; 57:524-532. [PMID: 27380800 PMCID: PMC5045079 DOI: 10.1093/jrr/rrw052] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Revised: 02/05/2016] [Accepted: 03/31/2016] [Indexed: 05/20/2023]
Abstract
The aim of this study was to compare the dosimetric parameters of whole-pelvic radiotherapy (WPRT) for cervical cancer among plans involving 3D conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), or spot-scanning proton therapy (SSPT). The dose distributions of 3D-CRT-, IMRT-, and SSPT-based WPRT plans were compared in 10 patients with cervical cancer. All of the patients were treated with a prescribed dose of 50.4 Gy in 1.8-Gy daily fractions, and all of the plans involved the same planning target volume (PTV) constrictions. A 3D-CRT plan involving a four-field box, an IMRT plan involving seven coplanar fields, and an SSPT plan involving four fields were created. The median PTV D95% did not differ between the 3D-CRT, IMRT and SSPT plans. The median conformity index 95% and homogeneity index of the IMRT and SSPT were better than those of the 3D-CRT. The homogeneity index of the SSPT was better than that of the IMRT. SSPT resulted in lower median V20 values for the bladder wall, small intestine, colon, bilateral femoral heads, skin, and pelvic bone than IMRT. Comparing the Dmean values, SSPT spared the small intestine, colon, bilateral femoral heads, skin and pelvic bone to a greater extent than the other modalities. SSPT can reduce the irradiated volume of the organs at risk compared with 3D-CRT and IMRT, while maintaining excellent PTV coverage. Further investigations of SSPT are warranted to assess its role in the treatment of cervical cancer.
Collapse
|
37
|
Improving target volume delineation in intact cervical carcinoma: Literature review and step-by-step pictorial atlas to aid contouring. Pract Radiat Oncol 2016; 6:e203-e213. [DOI: 10.1016/j.prro.2016.01.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2015] [Revised: 12/21/2015] [Accepted: 01/08/2016] [Indexed: 10/22/2022]
|
38
|
Quantitative assessment of target delineation variability for thymic cancers: Agreement evaluation of a prospective segmentation challenge. JOURNAL OF RADIATION ONCOLOGY 2016; 5:55-61. [PMID: 27570583 DOI: 10.1007/s13566-015-0230-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
OBJECTIVES We sought to quantitatively determine the inter-observer variability of expert radiotherapy target-volume delineation for thymic cancers, as part of a larger effort to develop an expert-consensus contouring atlas. METHODS A pilot dataset was created consisting of a standardized case presentation with pre- and post-operative DICOM CT image sets from a single patient with Masaoka-Koga Stage III thymoma. Expert thoracic radiation oncologists delineated tumor targets on the pre- and post-operative scans as they would for a definitive and adjuvant case, respectively. Respondents completed a survey including recommended dose prescription and target volume margins for definitive and post-operative scenarios. Inter-observer variability was analyzed quantitatively with Warfield's simultaneous truth, performance level estimation (STAPLE) algorithm and Dice similarity coefficient (DSC). RESULTS Seven users completed contouring for definitive and adjuvant cases; of these, 5 completed online surveys. Segmentation performance was assessed, with high mean±SD STAPLE-estimated segmentation sensitivity for definitive case GTV and CTV at 0.77 and 0.80, respectively, and post-operative CTV sensitivity of 0.55; all volumes had specificity of ≥0.99. Inter-observer agreement was markedly higher for the definitive target volumes, with mean±SD DSC of 0.88±0.03 and 0.89±0.04 for GTV and CTV respectively, compared to post-op CTV DSC of 0.69±0.06 (Kruskal-Wallis p<0.01. CONCLUSION Expert agreement for definitive case volumes was exceptionally high, though significantly lower agreement was noted post-operatively. Technique and dose prescription between experts was substantively consistent, and these preliminary results will be utilized to create an expert-consensus contouring atlas to aid the non-expert radiation oncologist in the planning of these challenging, rare tumors.
Collapse
|
39
|
Abstract
OBJECTIVES Pelvic lymph nodal regions receive an incidental dose from conformal treatment of the prostate. This study was conducted to investigate the doses received by the different pelvic nodal regions with varying techniques used for prostate radiotherapy. METHODS AND MATERIALS Twenty patients of high-risk node-negative prostate cancer treated with intensity-modulated radiotherapy to the prostate alone were studied. Replanning was done for intensity-modulated radiotherapy, 3-dimensional conformal treatment, and 2-dimensional conventional radiotherapy with additional delineation of the pelvic nodal regions, namely, common iliac (upper and lower), presacral, internal iliac, obturator, and external iliac. Dose-volume parameters such as Dmean, D100%, D66%, D33%, V40, and V50 to each of the nodal regions were estimated for all patients. RESULTS The obturator nodes received the highest dose among all nodal regions. The mean dose received by obturator nodal region was 44, 29, and 22 Gy from 2-dimensional conventional radiotherapy, 3-dimensional conformal treatment, and intensity-modulated radiotherapy, respectively. The mean dose was significantly higher when compared between 2-dimensional conventional radiotherapy and 3-dimensional conformal treatment ( P < .001), 2-dimensional conventional radiotherapy and intensity-modulated radiotherapy ( P < .001), and 3-dimensional conformal treatment and intensity-modulated radiotherapy ( P < .001). The D33% of the obturator region was 64, 39, and 37 Gy from 2-dimensional conventional radiotherapy, 3-dimensional conformal treatment, and intensity-modulated radiotherapy, respectively. The dose received by all other pelvic nodal regions was low and not clinically relevant. CONCLUSION The incidental dose received by obturator regions is significant especially with 2-dimensional conventional radiotherapy and 3-dimensional conformal treatment techniques as used in the trials studying elective pelvic nodal irradiation. However, with intensity-modulated radiotherapy, this dose is lower, making elective pelvic irradiation more relevant. Advances in Knowledge: This study highlights that incidental dose received by obturator regions is significant especially with 2-dimensional conventional radiotherapy and 3-dimensional conformal treatment techniques.
Collapse
|
40
|
Kidney-Sparing Methods for Extended-Field Intensity-Modulated Radiotherapy (EF-IMRT) in Cervical Carcinoma Treatment. PLoS One 2016; 11:e0156623. [PMID: 27258030 PMCID: PMC4892687 DOI: 10.1371/journal.pone.0156623] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Accepted: 05/17/2016] [Indexed: 12/25/2022] Open
Abstract
Coplanar extended-field intensity-modulated radiation therapy (EF-IMRT) targeting the whole-pelvic and para-aortic lymph nodes in patients with advanced cervical cancer results in impaired creatinine clearance. An improvement in renal function cannot be expected unless low-dose (approximately 10 Gy) kidney exposure is reduced. The dosimetric method should be considered during EF-IMRT planning to further reduce low-dose exposure to the kidneys. To assess the usefulness of non-coplanar EF-IMRT with kidney-avoiding beams to spare the kidneys during cervical carcinoma treatment in dosimetric analysis between non-coplanar and coplanar EF-IMRT, we compared the doses of the target organ and organs at risk, including the kidney, in 10 consecutive patients. To estimate the influence of EFRT on renal dysfunction, creatinine clearance values after treatment were also examined in 18 consecutive patients. Of these 18 patients, 10 patients who were included in the dosimetric analysis underwent extended field radiation therapy (EFRT) with concurrent chemotherapy, and eight patients underwent whole-pelvis radiation therapy with concurrent chemotherapy to treat cervical carcinoma between April 2012 and March 2015 at our institution. In the dosimetric analysis, non-coplanar EF-IMRT was effective at reducing low-dose (approximately 10 Gy) exposure to the kidneys, thus maintaining target coverage and sparing other organs at risk, such as the small bowel, rectum, and bladder, compared with coplanar EF-IMRT. Renal function in all 10 patients who underwent EFRT, including coplanar EF-IMRT (with kidney irradiation), was low after treatment, and differed significantly from that of the eight patients who underwent WPRT (no kidney irradiation) 6 months after the first day of treatment (P = 0.005). In conclusion, non-coplanar EF-IMRT should be considered in patients with advanced cervical cancer, particularly in patients with a long life expectancy or with pre-existing renal dysfunction.
Collapse
|
41
|
The dosimetric impact of target volume delineation variation for cervical cancer radiotherapy. Radiother Oncol 2016; 120:493-499. [PMID: 27162158 DOI: 10.1016/j.radonc.2016.04.028] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Revised: 02/18/2016] [Accepted: 04/19/2016] [Indexed: 11/16/2022]
Abstract
BACKGROUND Cervical cancer inter-observer delineation variation has been demonstrated. This article addresses its dosimetric impact. METHODS 21 centres outlined two INTERLACE trial quality assurance test cases. A gold standard clinical target volume (GSCTV) was created from a consensus and STAPLE outline. RapidArc plans were created for all centres' planning target volumes (PTVs; PTV1+2). Gold standard PTVs (GSPTVs) were created for each plan by applying each centre's CTV-PTV margins to GSCTV. DVH parameters including D95% and Dmean for each PTV1+2 and GSPTV were compared, representing planned versus GSPTV delivered dose. PTV1+2 and GSPTV V95% was also calculated. RESULTS Reviewing all parameters, no plans achieved acceptable GSPTV coverage. GSPTV V95%⩾95% was not achieved for any plan. GSPTV V95%<90% in 15/21 (case 1) and 14/22 (case 2) and <80% in 2 plans from both cases. GSPTV V95% is on average 10-15% lower than planned and GSPTV D95% is 10-20% lower than planned. Most common GSCTV anatomical areas not receiving 95% dose were vagina, obturator and external iliac nodes and, in case 1, the superior nodal aspect. CONCLUSION Cervical cancer CTV delineation variation leads to significant reductions in dose delivered to GSPTV. This highlights the ongoing importance of standardising delineation in the IMRT era.
Collapse
|
42
|
A phase II study of postoperative concurrent carboplatin and paclitaxel combined with intensity-modulated pelvic radiotherapy followed by consolidation chemotherapy in surgically treated cervical cancer patients with positive pelvic lymph nodes. Gynecol Oncol 2016; 141:240-246. [DOI: 10.1016/j.ygyno.2016.02.011] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Revised: 02/09/2016] [Accepted: 02/10/2016] [Indexed: 11/16/2022]
|
43
|
Intensity-Modulated Radiation Therapy Versus 3D Conformal Radiotherapy for Postoperative Gynecologic Cancer: Are They Covering the Same Planning Target Volume? Cureus 2016; 8:e467. [PMID: 26973802 PMCID: PMC4771573 DOI: 10.7759/cureus.467] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Background and Purpose: This study compares dosimetric parameters of planning target volume (PTV) coverage and organs at risk (OAR) sparing when postoperative radiotherapy for gynecologic cancers is delivered using volumetric modulated arc therapy (VMAT) versus a four-field (4FLD) box technique. Material and Methods: From July to December 2012, women requiring postoperative radiation for gynecologic cancers were treated with a standardized VMAT protocol. Two sets of optimized 4FLD plans were retrospectively generated: one based on standard anatomical borders (4FLD) and one based on the clinical target volume (CTV) created for VMAT with a 2 cm expansion guiding field border placement (4FLD+2). Ninety-five percent isodose curves were generated to evaluate PTV coverage. Results: VMAT significantly improved dose conformity compared with 4FLD and 4FLD+2 plans (p < 0.001) and provided additional coverage of the PTV posteriorly and superiorly, corresponding to coverage of the presacral and proximal iliac vessels. There was a significant reduction in dose to all OARs with VMAT, including a 58% reduction in the volume of the small bowel receiving more than 45 Gy (p=0.005). Conclusions: Despite treating a larger volume, radiotherapy using a 4FLD technique is less homogenous and provides inferior coverage of the PTV compared with VMAT. With meticulous treatment planning and delivery, VMAT effectively encompasses the PTV and minimizes dose to OARs.
Collapse
|
44
|
Variability of clinical target volume delineation for definitive radiotherapy in cervix cancer. Radiother Oncol 2015; 117:542-7. [DOI: 10.1016/j.radonc.2015.10.007] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 10/07/2015] [Accepted: 10/08/2015] [Indexed: 10/22/2022]
|
45
|
Intensity-modulated radiation therapy versus three-dimensional conformal radiation therapy with concurrent nedaplatin-based chemotherapy after radical hysterectomy for uterine cervical cancer: comparison of outcomes, complications, and dose-volume histogram parameters. Radiat Oncol 2015; 10:180. [PMID: 26300325 PMCID: PMC4554318 DOI: 10.1186/s13014-015-0486-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Accepted: 08/13/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The purpose of this study is to report our clinical outcomes using intensity-modulated radiation therapy (IMRT) for adjuvant treatment of cervical cancer, compared with three-dimensional conformal radiation therapy (3DCRT), in terms of tumor control, complications and dose-volume histogram (DVH) parameters. METHODS Between March 2008 and February 2014, 62 patients were treated with concurrent nedaplatin-based chemotherapy and whole-pelvic external beam radiation therapy (RT). Of these patients, 32 (52%) received 3DCRT and 30 (48%) received IMRT. RESULTS The median follow-up periods were 40 months (range 2-74 months). The 3-year overall survival rate (OS), locoregional control rate (LRC) and progression-free survival rate (PFS) were 92, 95 and 92% in the IMRT group, and 85, 82 and 70% in the 3DCRT group, respectively. A comparison of OS, LRC and PFS showed no significant differences between IMRT and 3DCRT. The 3-year cumulative incidences of grade 2 or higher chronic gastrointestinal (GI) complications were significantly lower with IMRT compared to 3DCRT (3% vs. 45%, p < .02) and in patients with V40 of the small bowel loops of ≤340 mL compared to those with >340 mL (3% vs. 45%, p < .001). Patients treated with IMRT had a higher incidence of grade 3 acute hematologic complications (p < .05). V40 and V45 of the small bowel loops or bowel bag were predictive for development of both acute and chronic GI complications. CONCLUSIONS Our results suggest that IMRT for adjuvant treatment of cervical cancer is useful for decreasing GI complications without worsening outcomes.
Collapse
|
46
|
A surveillance study of intensity-modulated radiation therapy for postoperative cervical cancer in Japan. JOURNAL OF RADIATION RESEARCH 2015; 56:735-41. [PMID: 25862699 PMCID: PMC4497393 DOI: 10.1093/jrr/rrv020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2014] [Revised: 02/08/2015] [Accepted: 03/10/2015] [Indexed: 05/22/2023]
Abstract
Intensity-modulated radiation therapy (IMRT) was recently introduced to the field of gynecologic malignancies; however, its value is not yet validated. A clinical trial is in preparation to investigate the efficacy and feasibility of IMRT for postoperative cervical cancer. The object of this study was to perform a surveillance study of IMRT for post-operative cervical cancer. A questionnaire regarding the precise methods of conducting IMRT was sent to six institutions that had already introduced IMRT for post-operative cervical cancer, and the data were analyzed. Half of the institutions used static IMRT and the others used volumetric-modulated arc therapy (VMAT). Most institutions used body-immobilizing devices for patient fixation. Most institutions instructed patients to fill their bladder before undergoing planning CT or daily treatment. While one institution inserted metallic markers and another one used radio-contrast-soaked gauze to visualize the vaginal cuff, the other institutions used nothing for vaginal cuff visualization. Most institutions defined the clinical target volumes according to the Japan Clinical Oncology Group or the Radiation Therapy Oncology Group guidelines. Only one institution used a prescribed dose based on 95% of the PTV (D(95)), while the rest used the mean dose (D(mean)). This valuable information from six leading institutions will be utilized in a future prospective clinical trial.
Collapse
|
47
|
A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer. JOURNAL OF RADIATION RESEARCH 2015; 56:539-45. [PMID: 25720771 PMCID: PMC4426928 DOI: 10.1093/jrr/rrv004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2014] [Accepted: 01/14/2015] [Indexed: 05/05/2023]
Abstract
The aim of this study was to compare the dosimetric parameters of whole-pelvis radiotherapy (WPRT) for cervical cancer between step-and-shoot IMRT (SaS-IMRT) and Helical Tomotherapy™ (HT). Retrospective analysis was performed on 20 cervical cancer patients who received WPRT in our center between January 2011 and January 2014. SaS-IMRT and HT treatment plans were generated for each patient. The dosimetric values for target coverage and organ-at-risk (OAR) sparing were compared according to the criteria of the International Commission on Radiation Units and Measurements 83 (ICRU 83) guidelines. Differences in beam-on time (BOT) were also compared. All the PTV dosimetric parameters (D5%, D50% and D95%) for the HT plan were (statistically significantly) of better quality than those for the SaS-IMRT plan (P-value < 0.001 in all respects). HT was also significantly more accurate than SaS-IMRT with respect to the D98% and Dmean of the CTV (P-values of 0.008 and <0.001, respectively). The median Conformity Index (CI) did not differ between the two plans (P-value = 0.057). However, the Uniformity Index for HT was significantly better than that for SaS-IMRT (P-value < 0.001). The median of D50% for the bladder, rectum and small bowel were significantly lower in HT planning than SaS-IMRT (P-value < 0.001). For D2%, we found that HT provided better sparing to the rectum and bladder (P-value < 0.001). However, the median of D2% for the small bowel was comparable for both plans. The median of Dmax of the head of the left femur was significantly lower in the HT plan, but this did not apply for the head of the right femur. BOT for HT was significantly shorter than for SaS-IMRT (P-value < 0.001). HT provided highly accurate plans, with more homogeneous PTV coverage and superior sparing of OARs than SaS-IMRT. In addition, HT enabled a shorter delivery time than SaS-IMRT.
Collapse
|
48
|
Which technique for radiation is most beneficial for patients with locally advanced cervical cancer? Intensity modulated proton therapy versus intensity modulated photon treatment, helical tomotherapy and volumetric arc therapy for primary radiation - an intraindividual comparison. Radiat Oncol 2015; 10:91. [PMID: 25896675 PMCID: PMC4404108 DOI: 10.1186/s13014-015-0402-z] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2015] [Accepted: 04/08/2015] [Indexed: 12/03/2022] Open
Abstract
Background To compare highly sophisticated intensity-modulated radiotherapy (IMRT) delivered by either helical tomotherapy (HT), RapidArc (RA), IMRT with protons (IMPT) in patients with locally advanced cervical cancer. Methods and materials Twenty cervical cancer patients were irradiated using either conventional IMRT, VMAT or HT; ten received pelvic (PEL) and ten extended field irradiation (EFRT). The dose to the planning-target volume A (PTV_A: cervix, uterus, pelvic ± para-aortic lymph nodes) was 1.8/50.4 Gy. The SIB dose for the parametrium (PTV_B), was 2.12/59.36 Gy. MRI-guided brachytherapy was administered with 5 fractions up to 25 Gy. For EBRT, the lower target constraints were 95% of the prescribed dose in 95% of the target volume. The irradiated small bowel (SB) volumes were kept as low as possible. For every patient, target parameters as well as doses to the organs at risk (SB, bladder, rectum) were evaluated intra-individually for IMRT, HT, VMAT and IMPT. Results All techniques provided excellent target volume coverage, homogeneity, conformity. With IMPT, there was a significant reduction of the mean dose (Dmean) of the SB from 30.2 ± 4.0 Gy (IMRT); 27.6 ± 5.6 Gy (HT); 34.1 ± 7.0 (RA) to 18.6 ± 5.9 Gy (IMPT) for pelvic radiation and 26.3 ± 3.2 Gy (IMRT); 24.0 ± 4.1 (HT); 25.3 ± 3.7 (RA) to 13.8 ± 2.8 Gy (IMPT) for patients with EFRT, which corresponds to a reduction of 38-52% for the Dmean (SB). Futhermore, the low dose bath (V10Gy) to the small bowel was reduced by 50% with IMPT in comparison to all photon techniques. Furthermore, Dmean to the bladder and rectum was decresed by 7-9 Gy with IMPT in patents with pelvic radiation and EFRT. Conclusion All modern techniques (were proved to be dosimetrically adequate regarding coverage, conformity and homogeneity of the target. Protons offered the best sparing of small bowel and rectum and therefore could contribute to a significant reduction of acute and late toxicity in cervical cancer treatment.
Collapse
|
49
|
Intensity-modulated whole pelvic radiotherapy provides effective dosimetric outcomes for cervical cancer treatment with lower toxicities. Cancer Radiother 2014; 18:745-52. [DOI: 10.1016/j.canrad.2014.08.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2014] [Revised: 07/24/2014] [Accepted: 08/05/2014] [Indexed: 11/29/2022]
|
50
|
Pelvic nodal CTV from L4-L5 or aortic bifurcation? An audit of the patterns of regional failures in cervical cancer patients treated with pelvic radiotherapy. Jpn J Clin Oncol 2014; 44:941-7. [PMID: 25104792 DOI: 10.1093/jjco/hyu107] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To assess the patterns of recurrence in cervical cancer patients treated with pelvic nodal clinical target volume at L4-L5 junction instead of aortic bifurcation. METHODS Records of patients with locally advanced cervical cancer treated with chemo-radiation were reviewed. Patients treated with standard pelvic fields (superior border of the field at L4/L5 junction), without any radiological evidence of regional lymphadenopathy (<10 mm) were included in the study. The level of aortic bifurcation was retrospectively documented on computed tomography. Patterns of recurrences were correlated to the aortic bifurcation and the superior border of the radiation fields (L4/L5). RESULTS Aortic bifurcation was above the radiation fields (above L4/5) in 82 of 116 (70.7%) patients. Of the nine patients that recurred above the radiation field, 5 (55%) were above L4/5 failures, i.e. between aortic bifurcation and L4/5, and 4 (45%) had para-aortic failures. On retrospective analysis, 16 patients were found to have subcentimeter lymph nodes and higher nodal failures (7/16) were observed in patients with subcentimeter regional lymph nodes at diagnosis. CONCLUSIONS Superior border of nodal clinical target volume should ideally include the aortic bifurcation instead of L4-L5 inter space in patients with locally advanced cervical cancer. Radiotherapy fields need to be defined cautiously in patients with subcentimeter pelvic lymph nodes.
Collapse
|