1
|
Hwang HS, Shin GW, Park HJ, Ryu CY, Jung GY. Micellar ordered structure effects on high-resolution CE-SSCP using Pluronic triblock copolymer blends. Electrophoresis 2013; 34:518-23. [DOI: 10.1002/elps.201200520] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Revised: 09/24/2012] [Accepted: 10/11/2012] [Indexed: 11/05/2022]
Affiliation(s)
- Hee Sung Hwang
- School of Interdisciplinary Bioscience and Bioengineering; Pohang University of Science and Technology; Pohang; Gyeongbuk; Republic of Korea
| | - Gi Won Shin
- Institute of Environmental and Energy Technology; Pohang University of Science and Technology; Pohang; Gyeongbuk; Republic of Korea
| | - Han Jin Park
- Department of Chemistry and Chemical Biology; Rensselaer Polytechnic Institute; Troy; NY; USA
| | - Chang Yeol Ryu
- Department of Chemistry and Chemical Biology; Rensselaer Polytechnic Institute; Troy; NY; USA
| | | |
Collapse
|
2
|
Krothapalli S, May MK, Hestekin CN. Capillary electrophoresis-single strand conformation polymorphism for the detection of multiple mutations leading to tuberculosis drug resistance. J Microbiol Methods 2012; 91:147-54. [PMID: 22884688 PMCID: PMC3699206 DOI: 10.1016/j.mimet.2012.07.021] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2012] [Revised: 07/19/2012] [Accepted: 07/20/2012] [Indexed: 11/23/2022]
Abstract
Drug resistant tuberculosis (TB) is a major health problem in both developed and developing countries. Mutations in the Mycobacterium (M.) tuberculosis bacterial genome, such as those to the rpoB gene and mabA-inhA promoter region, have been linked to TB drug resistance in against rifampicin and isoniazid, respectively. The rapid, accurate, and inexpensive identification of these and other mutations leading to TB drug resistance is an essential tool for improving human health. Capillary electrophoresis (CE) single strand conformation polymorphism (SSCP) can be a highly sensitive technique for the detection of genetic mutation that has not been previously explored for drug resistance mutations in M. tuberculosis. This work explores the potential of CE-SSCP through the optimization of variables such as polymer separation matrix concentration, capillary wall coating, electric field strength, and temperature on resolution of mutation detection. The successful detection of an rpoB gene mutation and two mabA-inhA promoter region mutations while simultaneously differentiating a TB-causing mycobacteria from a non-TB bacteria was accomplished using the optimum conditions of 4.5% (w/v) PDMA in a PDMA coated capillary at 20°C using a separation voltage of 278 V/cm. This multiplexed analysis that can be completed in a few hours demonstrates the potential of CE-SSCP to be an inexpensive and rapid analysis method.
Collapse
Affiliation(s)
- Sowmya Krothapalli
- University of Arkansas, Department of Biomedical Engineering, Fayetteville, AR 4188 Bell Engineering Center, Fayetteville, AR-72701
| | - Michael K. May
- University of Arkansas, Department of Biomedical Engineering, Fayetteville, AR 4188 Bell Engineering Center, Fayetteville, AR-72701
| | - Christa N. Hestekin
- University of Arkansas, Department of Biomedical Engineering, Fayetteville, AR 4188 Bell Engineering Center, Fayetteville, AR-72701
- University of Arkansas, Department of Chemical Engineering, Fayetteville, AR 3202 Bell Engineering Center, Fayetteville, AR-72701
| |
Collapse
|
3
|
Nagy T, Csordás M, Kósa Z, Góth L. A simple method for examination of polymorphisms of catalase exon 9: rs769217 in Hungarian microcytic anemia and beta-thalassemia patients. Arch Biochem Biophys 2012; 525:201-6. [PMID: 22286031 DOI: 10.1016/j.abb.2012.01.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2011] [Revised: 01/04/2012] [Accepted: 01/10/2012] [Indexed: 01/02/2023]
Abstract
Catalase decreases the high, toxic concentrations of hydrogen peroxide but it lets the physiological, low concentrations in the cells mainly for signaling purposes. Its decreased activity may contribute to development of several pathological conditions. Catalase mutations occur frequently in exon 9, these were examined with different, complicated and costly methods. The aim of the current study was to evaluate a method for screening of polymorphisms in catalase exon 9. We used the slab gel electrophoresis of PCR amplicons without denaturation and silver staining for visualization of the DNA bands. We detected extra DNA bands in the 400-800 bp region of the catalase exon 9. Their single stranded nature was proved with nucleotide sequence analyses, comparison with the standard SSCP, staining with Sybr Green II and Sybr Green I, ethidium bromide, no digestion with RFLP (BstX I), and digestion with plant nuclease. We used this method for examination of polymorphisms of catalase exon 9 in microcytic anemia and beta-thalassemia patients. The lowest blood catalase activities were detected in microcytic anemia and beta-thalassemia patients with the TT genotypes of the C111T polymorphism. This method was sensitive for detection of G113A acatalasemia mutation, but poorly detected C37T and G5A acatalasemia mutations.
Collapse
Affiliation(s)
- Teréz Nagy
- Department of Biomedical Laboratory and Imaging Science, Medical and Health Science Center, University of Debrecen, P.O. Box 55, Debrecen H-4012, Hungary
| | | | | | | |
Collapse
|
4
|
Li T, Zhang D, Luo W, Lu M, Wang Z, Song Y, Wang H. Metal Cation Mediated-Capillary Electrophoresis of Nucleic Acids. Anal Chem 2009; 82:487-90. [DOI: 10.1021/ac9025708] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Tao Li
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center For Eco-Environmental Sciences, Chinese Academy of Sciences, Shuangqing Road 18, Beijing 100085, China
| | - Dapeng Zhang
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center For Eco-Environmental Sciences, Chinese Academy of Sciences, Shuangqing Road 18, Beijing 100085, China
| | - Wenru Luo
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center For Eco-Environmental Sciences, Chinese Academy of Sciences, Shuangqing Road 18, Beijing 100085, China
| | - Meiling Lu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center For Eco-Environmental Sciences, Chinese Academy of Sciences, Shuangqing Road 18, Beijing 100085, China
| | - Zhixin Wang
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center For Eco-Environmental Sciences, Chinese Academy of Sciences, Shuangqing Road 18, Beijing 100085, China
| | - Yuling Song
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center For Eco-Environmental Sciences, Chinese Academy of Sciences, Shuangqing Road 18, Beijing 100085, China
| | - Hailin Wang
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center For Eco-Environmental Sciences, Chinese Academy of Sciences, Shuangqing Road 18, Beijing 100085, China
| |
Collapse
|
5
|
Imbalance of G and C contents influences the sensitivity of single-strand conformation polymorphism. Mol Biol Rep 2009; 37:1605-9. [PMID: 19449211 DOI: 10.1007/s11033-009-9571-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2008] [Accepted: 05/01/2009] [Indexed: 11/26/2022]
Abstract
After analyzing chicken ATPase6 by single-strand conformation polymorphism (SSCP), we observed two band species. But based on the sequencing results, we found two mutations, and one of them was not detected by SSCP. The primer P2 was designed to detect the additional mutation site, which was not detected by the original primer. And the P2 SSCP results then agreed with the sequencing data. Analysis of the percent of G and C bases and secondary structures indicated that it might be caused by a similar secondary structure which might be resulting from serious imbalance of G and C contents.
Collapse
|
6
|
Kuo HC, Su YL, Yang HL, Chen TY. Establishment and Application of PCR-SSCP Profile for Molecular Typing ofCordycepsFungi. FOOD BIOTECHNOL 2008. [DOI: 10.1080/08905430802458354] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
7
|
Gury J, Zinger L, Gielly L, Taberlet P, Geremia RA. Exonuclease activity of proofreading DNA polymerases is at the origin of artifacts in molecular profiling studies. Electrophoresis 2008; 29:2437-44. [PMID: 18429330 DOI: 10.1002/elps.200700667] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
CE fingerprint methods are commonly used in microbial ecology. We have previously noticed that the position and number of peaks in CE-SSCP (single-strand conformation polymorphism) profiles depend on the DNA polymerase used in PCR [1]. Here, we studied the fragments produced by Taq polymerase as well as four commercially available proofreading polymerases, using the V3 region of the Escherichia coli rss gene as a marker. PCR products rendered multiple peaks in denaturing CE; Taq polymerase was observed to produce the longest fragments. Incubation of the fragments with T4 DNA polymerase indicated that the 3'-ends of the proofreading polymerase amplicons were recessed, while the Taq amplicon was partially +A tailed. Treatment of the PCR product with proofreading DNA polymerase rendered trimmed fragments. This was due to the 3'-5' exonuclease activity of these enzymes, which is essential for proofreading. The nuclease activity was reduced by increasing the concentration of dNTP. The Platinum Pfx DNA polymerase generated very few artifacts and could produce 85% of blunted PCR products. Nevertheless, despite the higher error rate, we recommend the use of Taq polymerase rather than proofreading in the framework for molecular fingerprint studies. They are more cost-effective and therefore ideally suited for high-throughput analysis; the +A tail artifact rate can be controlled by modifying the PCR primers and the reaction conditions.
Collapse
Affiliation(s)
- Jerome Gury
- Laboratoire d'écologie alpine, UMR UJF-CNRS 5553, Université Joseph Fourier, Grenoble, France
| | | | | | | | | |
Collapse
|
8
|
Atha DH. High-throughput DNA diagnostic measurements using capillary electrophoresis: p53, fragile X and telomerase. EXPERT OPINION ON MEDICAL DIAGNOSTICS 2008; 2:91-100. [PMID: 23485119 DOI: 10.1517/17530059.2.1.91] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Capillary electrophoresis (CE) has become recognized as a powerful tool for the characterization of DNA. It has numerous advantages over slab-gel electrophoresis in that it is fast, highly reproducible and easy to automate. It is well known for its contribution to success in sequencing the human genome, but it is equally important in a wide range of forensic and pharmaceutical applications. Of these applications, CE plays a large and important role in mutation scanning and DNA sizing. From the author's laboratory, three previously published examples are given of clinical applications in this area that have benefited from the use of capillary electrophoresis: the detection of p53 mutations by single strand conformational polymorphism, the analysis of fragile X syndrome and the measurement of telomerase activity. There are many examples from other laboratories where CE has played an important role in this field. For acceptance by the medical community, there must be a clear demonstration that capillary electrophoresis can replace and improve previous slab-gel methods. In this regard, the examples given in this review help to demonstrate that CE can replace previous slab-gel methods and show that CE can improve a wide range of applications in the medical field.
Collapse
Affiliation(s)
- Donald H Atha
- National Institute of Standards and Technology, Biochemical Science Division, 100 Bureau Drive, MS 8311, Gaithersburg, MD 20899, USA +1 301 975 3092 ; +1 301 975 8505 ;
| |
Collapse
|
9
|
Affiliation(s)
- Karel Klepárník
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veveří 97, CZ-602 00 Brno, Czech Republic
| | - Petr Boček
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veveří 97, CZ-602 00 Brno, Czech Republic
| |
Collapse
|
10
|
Zinger L, Gury J, Alibeu O, Rioux D, Gielly L, Sage L, Pompanon F, Geremia RA. CE-SSCP and CE-FLA, simple and high-throughput alternatives for fungal diversity studies. J Microbiol Methods 2007; 72:42-53. [PMID: 18054096 DOI: 10.1016/j.mimet.2007.10.005] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2007] [Revised: 10/12/2007] [Accepted: 10/12/2007] [Indexed: 11/18/2022]
Abstract
Fungal communities are key components of soil, but the study of their ecological significance is limited by a lack of appropriated methods. For instance, the assessment of fungi occurrence and spatio-temporal variation in soil requires the analysis of a large number of samples. The molecular signature methods provide a useful tool to monitor these microbial communities and can be easily adapted to capillary electrophoresis (CE) allowing high-throughput studies. Here we assess the suitability of CE-FLA (Fragment Length Polymorphism, denaturing conditions) and CE-SSCP (Single-Stranded Conformation Polymorphism, native conditions) applied to environmental studies since they require a short molecular marker and no post-PCR treatments. We amplified the ITS1 region from 22 fungal strains isolated from an alpine ecosystem and from total genomic DNA of alpine and infiltration basin soils. The CE-FLA and CE-SSCP separated 17 and 15 peaks respectively from a mixture of 19 strains. For the alpine soil-metagenomic DNA, the FLA displayed more peaks than the SSCP and the converse result was found for infiltration basin sediments. We concluded that CE-FLA and CE-SSCP of ITS1 region provided complementary information. In order to improve CE-SSCP sensitivity, we tested its resolution according to migration temperature and found 32 degrees C to be optimal. Because of their simplicity, quickness and reproducibility, we found that these two methods were promising for high-throughput studies of soil fungal communities.
Collapse
Affiliation(s)
- Lucie Zinger
- Laboratoire d'Ecologie Alpine UMR 5553 UJF/CNRS, Grenoble Cedex 9, France
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Hestekin CN, Barron AE. The potential of electrophoretic mobility shift assays for clinical mutation detection. Electrophoresis 2006; 27:3805-15. [PMID: 17031787 DOI: 10.1002/elps.200600421] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
As the understanding of the links between genetic mutations and diseases continues to grow, there is an increasing need for techniques that can rapidly, inexpensively, and sensitively detect DNA sequence alterations. Typically, such analyses are performed on PCR-amplified gene regions. Automated DNA sequencing by capillary array electrophoresis can be used, but is expensive to apply to large numbers of patient samples and/or large genes, and may not always reveal low-abundance mutations in heterozygous samples. Many different types of genetic differences need to be detected, including single-base substitutions and larger sequence alterations such as insertions, deletions, and inversions. Electrophoretic mobility shift assays seem well suited to this purpose and could be used for the efficient screening of patient samples for sequence alterations, effectively reducing the number of samples that must be subjected to full and careful sequencing. While there is much promise, many of the mobility shift assays presently under development have yet to be demonstrated to have the high sensitivity and specificity of mutation detection required for routine clinical application. Hence, further studies and optimization are required, in particular the application of these methods not only to particular genes but also to large numbers of patient samples in blinded studies aimed at the rigorous determination of sensitivity and specificity. This review examines the state-of-the-art of the most commonly used mobility shift assays for mutation detection, including denaturing gradient gel electrophoresis, TGGE, SSCP, heteroduplex analysis, and denaturing HPLC.
Collapse
Affiliation(s)
- Christa N Hestekin
- Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL, USA
| | | |
Collapse
|
12
|
Schatz P, Distler J, Berlin K, Schuster M. Novel method for high throughput DNA methylation marker evaluation using PNA-probe library hybridization and MALDI-TOF detection. Nucleic Acids Res 2006; 34:e59. [PMID: 16670426 PMCID: PMC1456329 DOI: 10.1093/nar/gkl218] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
The methylation of CpG dinucleotides has become a topic of great interest in cancer research, and the methylation of promoter regions of several tumor suppressor genes has been identified as a marker of tumorigenesis. Evaluation of DNA methylation markers in tumor tissue requires hundreds of samples, which must be analyzed quantitatively due to the heterogeneous composition of biological material. Therefore novel, fast and inexpensive methods for high throughput analysis are needed. Here we introduce a new assay based on peptide nucleic acid (PNA)-library hybridization and subsequent MALDI-TOF analysis. This method is multiplexable, allows the use of standard 384 well automated pipetting, and is more specific and flexible than established methods, such as microarrays and MS-SNuPE. The approach was used to evaluate three candidate colon cancer methylation markers previously identified in a microarray study. The methylation of the genes Ade-nomatous polyposis coli (APC), glycogen synthase kinase-beta-3 (GSK3beta) and eyes absent 4 (EYA4) was analyzed in 12 colon cancer and 12 normal tissues. APC and EYA4 were confirmed as being differentially methylated in colon cancer patients whereas GSK3beta did not show differential methylation.
Collapse
Affiliation(s)
| | | | | | - Matthias Schuster
- To whom correspondence should be addressed. Tel: +49 30 24345100; Fax: +49 30 24345555;
| |
Collapse
|
13
|
Kuhn DN, Borrone J, Meerow AW, Motamayor JC, Brown JS, Schnell RJ. Single-strand conformation polymorphism analysis of candidate genes for reliable identification of alleles by capillary array electrophoresis. Electrophoresis 2005; 26:112-25. [PMID: 15624191 DOI: 10.1002/elps.200406106] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
We investigated the reliability of capillary array electrophoresis-single strand conformation polymorphism (CAE-SSCP) to determine if it can be used to identify novel alleles of candidate genes in a germplasm collection. Both strands of three different size fragments (160, 245 and 437 bp) that differed by one or more nucleotides in sequence were analyzed at four different temperatures (18 degrees C, 25 degrees C, 30 degrees C, and 35 degrees C). Mixtures of amplified fragments of either the intron interrupting the C-terminal WRKY domain of the Tc10 locus or the NBS domain of the TcRGH1 locus of Theobroma cacao were electroinjected into all 16 capillaries of an ABI 3100 Genetic Analyzer and analyzed three times at each temperature. Multiplexing of samples of different size range is possible, as intermediate and large fragments were analyzed simultaneously in these experiments. A statistical analysis of the means of the fragment mobilities demonstrated that single-stranded conformers of the fragments could be reliably identified by their mobility at all temperatures and size classes. The order of elution of fragments was not consistent over strands or temperatures for the intermediate and large fragments. If samples are only run once at a single temperature, small fragments could be identified from a single strand at a single temperature. A combination of data from both strands of a single run was needed to identify correctly all four of the intermediate fragments and no combination of data from strands or temperatures would allow the correct identification of two large fragments that differed by only a single single-nucleotide polymorphism (SNP) from a single run. Thus, to adequately assess alleles at a candidate gene locus using SSCP on a capillary array, fragments should be < or =250 bp, samples should be analyzed at two different temperatures between 18 degrees C and 30 degrees C to reduce the variability introduced by the capillaries, data should be combined from both strands and both temperatures, and undenatured double-stranded (ds)DNA molecular weight standards, such as ROX 2500, should be included as internal standards.
Collapse
Affiliation(s)
- David N Kuhn
- Department of Biological Sciences, Florida International University, Miami, FL 33199, USA.
| | | | | | | | | | | |
Collapse
|
14
|
Kozlowski P, Krzyzosiak WJ. Structural factors determining DNA length limitations in conformation-sensitive mutation detection methods. Electrophoresis 2005; 26:71-81. [PMID: 15624145 DOI: 10.1002/elps.200406125] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Numerous mutations and polymorphisms in human genes remain to be identified using reliable methods. Of the available mutation scanning methods those dependent on structural change-induced mobility shifts are highly effective. Their efficiency is, however, DNA length-sensitive and the reasons for that are poorly understood. In this study, we explain why scanning genes for mutations is less effective in longer DNA fragments, and reveal the factors which are behind this effect. We have performed a systematic analysis of the same sequence variants of exon 11 of the BRCA1 gene in DNA fragments of three different lengths using the combined single-strand conformation polymorphism (SSCP) and heteroduplex analysis (DA) by capillary electrophoresis (CE). There are two major structural factors responsible for the reduced mutation detection rate in long amplicons. The first is increased contribution from other secondary structure modules and domains in longer fragments, which mask the structural change induced by the mutation. The second is higher frequency of single-nucleotide polymorphisms (SNPs) including common polymorphisms in longer fragments. This makes it necessary to distinguish the structural effect of the mutation from that of each polymorphic variant, which is often difficult to achieve. Taking these factors into account, an efficient scanning of genes for sequence variants by conformation-sensitive methods may be performed.
Collapse
Affiliation(s)
- Piotr Kozlowski
- Laboratory of Cancer Genetics, Institute of Bioorganic Chemistry, Polish Academy of Sciences, Poznan, Poland
| | | |
Collapse
|
15
|
Junca H, Pieper DH. Functional gene diversity analysis in BTEX contaminated soils by means of PCR-SSCP DNA fingerprinting: comparative diversity assessment against bacterial isolates and PCR-DNA clone libraries. Environ Microbiol 2004; 6:95-110. [PMID: 14756875 DOI: 10.1046/j.1462-2920.2003.00541.x] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Developments in molecular biology based techniques have led to rapid and reliable tools to characterize microbial community structures and to monitor their dynamics under in situ conditions. However, there has been a distinct lack of emphasis on monitoring the functional diversity in the environment. Genes encoding catechol 2,3-dioxygenases (C23O), as key enzymes of various aerobic aromatic degradation pathways, were used as functional targets to assess the catabolic gene diversity in differentially BTEX contaminated environments by polymerase chain reaction-single-strand conformation polymorphism (PCR-SSCP). Site specific PCR-SSCP fingerprints were obtained, showing that gene diversity experienced shifts correlated to temporal changes and levels of contamination. PCR-SSCP enabled the recovery of predominant gene polymorphs, and results closely matched with the information retrieved from random sequencing of PCR-DNA clone libraries. A new method for isolating strains capable of growing on BTEX compounds was developed to diminish preselection or enrichment bias and to assess the function of predominant gene polymorphs. C23O abundance in isolates correlated with the levels of BTEX pollution in the soil samples analysed. Isolates harbouring C23O genes, identical to the gene polymorph predominant in all contaminated sites analysed, showed an unexpected benzene but not toluene mineralizing phenotype whereas isolates harbouring a C23O gene variant differing by a single point mutation and observed in highly polluted sites only, were capable, among some other isolates, to mineralize benzene and toluene, indicating a catabolically determined sharing of carbon sources on-site. The PCR-SSCP technique is thus a powerful tool for assessing the diversity of functional genes and the identification of predominant gene polymorphs in environmental samples as a prerequisite to understand the functioning of microbial communities.
Collapse
Affiliation(s)
- Howard Junca
- Department of Environmental Microbiology, GBF-German Research Centre for Biotechnology, Mascheroder Weg 1, D-38124 Braunschweig, Germany
| | | |
Collapse
|
16
|
Andersen PS, Jespersgaard C, Vuust J, Christiansen M, Larsen LA. High-throughput single strand conformation polymorphism mutation detection by automated capillary array electrophoresis: validation of the method. Hum Mutat 2003; 21:116-22. [PMID: 12552558 DOI: 10.1002/humu.10161] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Capillary array electrophoresis (CAE) is a novel technique, which allows for high throughput analysis of DNA fragments. When screening for mutations in whole populations or large patient groups it is necessary to have robust and well-characterized setups for high throughput analysis. For large-scale mutation screening, we have developed procedures for single strand conformation polymorphism (SSCP) assays using CAE (CAE-SSCP) whereby we may increase both the sensitivity and the throughput compared to conventional SSCP analysis. In this study we have validated CAE-SSCP by 1) comparing detection by slab-gel based SSCP with CAE-SSCP of mutations in the MYH7, MYL2, and MYL3 genes encoding sarcomere proteins from patients suffering from hypertrophic cardiomyopathy; and 2) by constructing a series of 185 mutants having substitution mutations, as well as insertion/deletion mutations, or some combinations of these, in different sequence contexts in four exons and different positions relative to the end of the amplicon (three from the KCNQ1 gene, encoding a cardiac potassium channel, and one from the TNNI3 gene encoding cardiac troponin I). The method identified 181 out of 185 mutations (98%), and the data suggest that the position of mutation in the fragment had no effect on the sensitivity. Analysis of the specificity of the method showed that only very few mutants could not be distinguished from each other and there were no false positives.
Collapse
Affiliation(s)
- Paal Skytt Andersen
- Department of Clinical Biochemistry, Statens Serum Institut, Copenhagen, Denmark.
| | | | | | | | | |
Collapse
|
17
|
Glavac D, Potocnik U, Podpecnik D, Zizek T, Smerkolj S, Ravnik-Glavac M. Correlation of MFOLD-predicted DNA secondary structures with separation patterns obtained by capillary electrophoresis single-strand conformation polymorphism (CE-SSCP) analysis. Hum Mutat 2002; 19:384-94. [PMID: 11933192 DOI: 10.1002/humu.10086] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We have studied 57 different mutations within three beta-globin gene promoter fragments with sizes 52 bp, 77 bp, and 193 bp by fluorescent capillary electrophoresis CE-SSCP analysis. For each mutation and wild type, energetically most-favorable predicted secondary structures were calculated for sense and antisense strands using the MFOLD DNA-folding algorithm in order to investigate if any correlation exists between predicted DNA structures and actual CE migration time shifts. The overall CE-SSCP detection rate was 100% for all mutations in three studied DNA fragments. For shorter 52 bp and 77 bp DNA fragments we obtained a positive correlation between the migration time shifts and difference in free energy values of predicted secondary structures at all temperatures. For longer 193 bp beta-globin gene fragments with 46 mutations MFOLD predicted different secondary structures for 89% of mutated strands at 25 degrees C and 40 degrees C. However, the magnitude of the mobility shifts did not necessarily correlate with their secondary structures and free energy values except for the sense strand at 40 degrees C where this correlation was statistically significant (r = 0.312, p = 0.033). Results of this study provided more direct insight into the mechanism of CE-SSCP and showed that MFOLD prediction could be helpful in making decisions about the running temperatures and in prediction of CE-SSCP data patterns, especially for shorter (50-100 bp) DNA fragments.
Collapse
Affiliation(s)
- Damjan Glavac
- Laboratory of Molecular Genetics, Institute of Pathology, Ljubljana, Slovenia
| | | | | | | | | | | |
Collapse
|