1
|
Ammar A, Koshyk A, Kohut M, Alolabi B, Quenneville CE. The Use of Optical Tracking to Characterize Fracture Gap Motions and Estimate Healing Potential in Comminuted Biomechanical Models of Surgical Repair. Ann Biomed Eng 2023; 51:2258-2266. [PMID: 37294414 DOI: 10.1007/s10439-023-03265-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 05/31/2023] [Indexed: 06/10/2023]
Abstract
Fracture healing is stimulated by micromotion at the fracture site, whereby there exists an optimal amount of strain to promote secondary bone formation. Surgical plates used for fracture fixation are often evaluated for their biomechanical performance using benchtop studies, where success is based on overall construct stiffness and strength measures. Integration of fracture gap tracking to this assessment would provide crucial information about how plates support the various fragments present in comminuted fractures, to ensure there are appropriate levels of micromotion during early healing. The goal of this study was to configure an optical tracking system to quantify 3D interfragmentary motion to assess the stability (and corresponding healing potential) of comminuted fractures. An optical tracking system (OptiTrack, Natural Point Inc, Corvallis, OR) was mounted to a material testing machine (Instron 1567, Norwood, MA, USA), with an overall marker tracking accuracy of 0.05 mm. Marker clusters were constructed that could be affixed to individual bone fragments, and segment-fixed coordinate systems were developed. The interfragmentary motion was calculated by tracking the segments while under load and was resolved into compression-extraction and shear components. This technique was evaluated using two cadaveric distal tibia-fibula complexes with simulated intra-articular pilon fractures. Normal and shear strains were tracked during cyclic loading (for stiffness tests), and a wedge gap was also tracked to assess failure in an alternate clinically relevant mode. This technique will augment the utility of benchtop fracture studies by moving beyond total construct response and providing anatomically relevant data on interfragmentary motion, a valuable proxy for healing potential.
Collapse
Affiliation(s)
- A Ammar
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| | - A Koshyk
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada
| | - M Kohut
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| | - B Alolabi
- Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - C E Quenneville
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.
- Department of Mechanical Engineering, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
2
|
Glatt V, O'Toole R, Mehta S, Kandemir U, Ricci W, Nauth A, Schemitsch E, Hast MW. Great debates in trauma biomechanics. OTA Int 2023; 6:e249. [PMID: 37168029 PMCID: PMC10166369 DOI: 10.1097/oi9.0000000000000249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 12/22/2022] [Indexed: 05/13/2023]
Abstract
At the 2021 annual meeting of the Orthopaedic Trauma Association, the Basic Science Focus Forum hosted its first ever debate-style symposium focused on biomechanics and fracture repair. The 3 subjects of debate were "Mechanics versus Biology-Which is 'More Important' to Consider?" "Locked Plate versus Forward Dynamization versus Reverse Dynamization-Which Way Should I Go?" and "Sawbones versus Cadaver Models-What Should I Believe Most?" These debates were held because fracture healing is a highly organized synergistic response between biological factors and the local mechanical environment. Multiple studies have demonstrated that both factors play roles in governing bone healing responses, and the causal relationships between the 2 remain unclear. The lack of clarity in this space has led to a spectrum of research with the common goal of helping surgeons make good decisions. Before reading further, the reader should understand that the questions posed in the debate titles are unanswerable and might represent a false choice. Instead, the reader should appreciate that the debates were held to gain a more thorough understanding of these topics based on the current state of the art of experimental and clinical studies, by using an engaging and thought-provoking format.
Collapse
Affiliation(s)
- Vaida Glatt
- Department of Orthopaedic Surgery, University of Texas Health Science Center San Antonio, San Antonio, TX
| | - Robert O'Toole
- Department of Orthopaedic Surgery, University of Maryland Medical System, Baltimore, MD
| | - Samir Mehta
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA
| | - Utku Kandemir
- Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, CA
| | - William Ricci
- Department of Orthopaedic Surgery, Hospital for Special Surgery and New York Presbyterian Hospital, New York, NY
| | - Aaron Nauth
- Department of Orthopaedic Surgery, University of Toronto, Toronto, ON, Canada; and
| | - Emil Schemitsch
- Department of Orthopaedic Surgery, Western University, London, ON, Canada
| | - Michael W. Hast
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA
| |
Collapse
|
3
|
North K, Simpson GM, Stuart AR, Kubiak EN, Petelenz TJ, Hitchcock RW, Rothberg DL, Cizik AM. Early postoperative step count and walking time have greater impact on lower limb fracture outcomes than load-bearing metrics. Injury 2023:S0020-1383(23)00388-1. [PMID: 37202224 DOI: 10.1016/j.injury.2023.04.043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/11/2023] [Accepted: 04/23/2023] [Indexed: 05/20/2023]
Abstract
INTRODUCTION Weight-bearing protocols for rehabilitation of lower extremity fractures are the gold standard despite not being data-driven. Additionally, current protocols are focused on the amount of weight placed on the limb, negating other patient rehabilitation behaviors that may contribute to outcomes. Wearable sensors can provide insight into multiple aspects of patient behavior through longitudinal monitoring. This study aimed to understand the relationship between patient behavior and rehabilitation outcomes using wearable sensors to identify the metrics of patient rehabilitation behavior that have a positive effect on 1-year rehabilitation outcomes. METHODS Prospective observational study on 42 closed ankle and tibial fracture patients. Rehabilitation behavior was monitored continuously between 2 and 6 weeks post-operative using a gait monitoring insole. Metrics describing patient rehabilitation behavior, including step count, walking time, cadence, and body weight per step, were compared between patient groups of excellent and average rehabilitation outcomes, as defined by the 1-year Patient Reported Outcome Measure Physical Function t-score (PROMIS PF). A Fuzzy Inference System (FIS) was used to rank metrics based on their impact on patient outcomes. Additionally, correlation coefficients were calculated between patient characteristics and principal components of the behavior metrics. RESULTS Twenty-two patients had complete insole data sets, and 17 of which had 1-year PROMIS PF scores (33.7 ± 14.5 years of age, 13 female, 9 in Excellent group, 8 in Average group). Step count had the highest impact ranking (0.817), while body weight per step had a low impact ranking (0.309). No significant correlation coefficients were found between patient or injury characteristics and behavior principal components. General patient rehabilitation behavior was described through cadence (mean of 71.0 steps/min) and step count (logarithmic distribution with only ten days exceeding 5,000 steps/day). CONCLUSION Step count and walking time had a greater impact on 1-year outcomes than body weight per step or cadence. The results suggest that increased activity may improve 1-year outcomes for patients with lower extremity fractures. The use of more accessible devices, such as smart watches with step counters combined with patient reported outcome measures may provide more valuable insights into patient rehabilitation behaviors and their effect on rehabilitation outcomes.
Collapse
Affiliation(s)
- Kylee North
- University of Utah Department of Biomedical Engineering, 36 S Wasatch Dr, Salt Lake City, UT 84112, United States
| | - Grange M Simpson
- University of Utah Department of Biomedical Engineering, 36 S Wasatch Dr, Salt Lake City, UT 84112, United States
| | - Ami R Stuart
- Medtronic, 710 Medtronic Parkway, Minneapolis, MN 55432-5604 USA
| | - Erik N Kubiak
- University of Nevada Las Vegas Department of Orthopaedics, University of Nevada, Las Vegas, 4505 S. Maryland Pkwy, Las Vegas, NV 89154
| | - Tomasz J Petelenz
- University of Utah Department of Biomedical Engineering, 36 S Wasatch Dr, Salt Lake City, UT 84112, United States
| | - Robert W Hitchcock
- University of Utah Department of Biomedical Engineering, 36 S Wasatch Dr, Salt Lake City, UT 84112, United States
| | - David L Rothberg
- University of Utah Department of Orthopaedics, 590 Wakara Way, Salt Lake City, Utah 84108
| | - Amy M Cizik
- University of Utah Department of Orthopaedics, 590 Wakara Way, Salt Lake City, Utah 84108.
| |
Collapse
|
4
|
Guo Y, Hu Z, Chen J, Zhang Z, Liu Q, Li J, Yang J, Ma Z, Zhao J, Hu J, Wu J, Chen Z. Injectable TG-linked recombinant human collagen hydrogel loaded with bFGF for rat cranial defect repair. Int J Biol Macromol 2023; 236:123864. [PMID: 36871688 DOI: 10.1016/j.ijbiomac.2023.123864] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 02/20/2023] [Accepted: 02/24/2023] [Indexed: 03/06/2023]
Abstract
The basic fibroblast growth factor (bFGF) plays a significant role in promoting the process of bone repair, but bFGF cannot keep its biological activity stable under normal physiological conditions. Therefore, the development of better biomaterials to carry bFGF remains a challenge for bone repair and regeneration. Here we designed a novel recombinant human collagen (rhCol), which could be cross-linked by transglutaminase (TG) and loaded bFGF to prepare rhCol/bFGF hydrogels. The rhCol hydrogel possessed a porous structure and good mechanical properties. The assays, including cell proliferation, migration, and adhesion assay, were performed to evaluate the biocompatibility of rhCol/bFGF and the results demonstrated that the rhCol/bFGF promoted cell proliferation, migration and adhesion. The rhCol/bFGF hydrogel degraded and released bFGF controllably, enhancing utilization rate of bFGF and allowing osteoinductive activity. The results of RT-qPCR and immunofluorescence staining also proved that rhCol/bFGF promoted expression of bone-related proteins. The rhCol/bFGF hydrogels were applied in the cranial defect in rats and the results confirmed that it accelerates bone defect repair. In conclusion, rhCol/bFGF hydrogel has excellent biomechanical properties and can continuously release bFGF to promote bone regeneration, suggesting that rhCol/bFGF hydrogel is a potential scaffold in clinic application.
Collapse
Affiliation(s)
- Yayuan Guo
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Zeyu Hu
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Jilong Chen
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Zhen Zhang
- School of Biomedical Engineering, Sun Yat-sen University, Shenzhen 518107, China
| | - Qian Liu
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Juan Li
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Jiaojiao Yang
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Zihan Ma
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Jing Zhao
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Jingyan Hu
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Jiawei Wu
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China
| | - Zhuoyue Chen
- Provincial Key Laboratory of Biotechnology of Shaanxi, Key Laboratory of Resource Biology and Modern Biotechnology in Western China, Faculty of Life Science, Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, School of Medicine, Northwest University, 229 North Taibai Road, Xi'an, Shaanxi Province 710069, China.
| |
Collapse
|
5
|
Gupta R, Schmidt EC, Namdari S, Stone MA, Hast MW. The addition of cerclage wiring does not improve proximal bicortical fixation of locking plates for Type C periprosthetic fractures in synthetic humeri. Clin Biomech (Bristol, Avon) 2022; 97:105709. [PMID: 35780699 PMCID: PMC10096358 DOI: 10.1016/j.clinbiomech.2022.105709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 06/05/2022] [Accepted: 06/14/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Treatment of proximal humerus periprosthetic fractures is challenging. It remains difficult to achieve robust fixation of the proximal fragment to the locking plate using cerclage wiring and/or unicortical screws. Use of polyaxial tangentially directed bicortical locking screws increases screw purchase, but it is unclear if this option provides robust fixation. This biomechanical study compares fixation of constructs using cerclage wires, bicortical locking screws, and a hybrid method utilizing both methods. METHODS Uncemented humeral stems were implanted into synthetic humeri and Type C periprosthetic fractures were simulated with a 1 cm transverse osteotomy. Distal ends of locking plates were secured with bicortical non-locking screws. The proximal ends were supported by either isolated cerclage wires, polyaxial locking screws, or a hybrid combination of both (n = 6 for each group). A universal test frame was used for non-destructive torsion and cyclic axial compression tests. 3-D motion tracking was employed to determine stiffnesses and relative interfragmentary motions. FINDINGS Isolated screw constructs showed significantly increased resistance against torsional movement, bending, and shear, (p < 0.05) in comparison to cerclage constructs. The hybrid construct provided no significant changes in stability over the isolated screw construct. INTERPRETATION Addition of cerclage wires in this synthetic bone model of Type C periprosthetic humerus fractures did not add significant stability to proximal bicortical locking plate fixation. Considering risks of tissue stripping and nerve injury, usage of cerclage wires in a similar clinical setting should be chosen carefully, especially when bicortical fixation around the prosthetic stem can be achieved.
Collapse
Affiliation(s)
- Richa Gupta
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
| | - Elaine C Schmidt
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Surena Namdari
- Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA, USA.
| | - Michael A Stone
- Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA, USA
| | - Michael W Hast
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
6
|
Liu X, Miramini S, Patel M, Liao J, Shidid D, Zhang L. Influence of therapeutic grip exercises induced loading rates in distal radius fracture healing with volar locking plate fixation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 215:106626. [PMID: 35051836 DOI: 10.1016/j.cmpb.2022.106626] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 12/25/2021] [Accepted: 01/07/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Therapeutic exercises could potentially enhance the healing of distal radius fractures (DRFs) treated with volar locking plate (VLP). However, the healing outcomes are highly dependant on the patient-specific fracture geometries (e.g., gap size) and the loading conditions at the fracture site (e.g., loading frequency) resulted from different types of therapeutic exercises. The purpose of this study is to investigate the effects of different loading frequencies induced by therapeutic exercises on the biomechanical microenvironment of the fracture site and the transport of cells and growth factors within the fracture callus, ultimately the healing outcomes. This is achieved through numerical modelling and mechanical testing. METHODS Five radius sawbones specimens (Pacific Research Laboratories, Vashon, USA) fixed with VLP (VRP2.0+, Austofix) were mechanically tested using dynamic test instrument (INSTRON E3000, Norwood, MA). The loading protocol used in mechanical testing involved a series of cyclic axial compression tests representing hand and finger therapeutic exercises. The relationship between the dynamic loading rate (i.e., loading frequency) and dynamic stiffness of the construct was established and used as inputs to a developed numerical model for studying the dynamic loading induced cells and growth factors in fracture site and biomechanical stimuli required for healing. RESULTS There is a strong positive linear relationship between the loading rate and axial stiffness of the construct fixed with VLP. The loading rates induced by the moderate frequencies (i.e., 1-2 Hz) could promote endochondral ossification, whereas relatively high loading frequencies (i.e., over 3 Hz) may hinder the healing outcomes or lead to non-union. In addition, a dynamic loading frequency of 2 Hz in combination of a fracture gap size of 3 mm could produce a better healing outcome by enhancing the transport of cells and growth factors at the fracture site in comparison to free diffusion (i.e. without loading), and thereby produces a biomechanical microenvironment which is favourable for healing. CONCLUSION The experimentally validated numerical model presented in this study could potentially contribute to the design of effective patient-specific therapeutic exercises for better healing outcomes. Importantly, the model results demonstrate that therapeutic grip exercises induced dynamic loading could produce a better biomechanical microenvironment for healing without compromising the mechanical stability of the overall volar locking plate fixation construct.
Collapse
Affiliation(s)
- Xuanchi Liu
- Department of Infrastructure Engineering, The University of Melbourne, Parkville, Victoria, Australia
| | - Saeed Miramini
- Department of Infrastructure Engineering, The University of Melbourne, Parkville, Victoria, Australia
| | - Minoo Patel
- Centre for Limb Lengthening and Reconstruction, Epworth Hospital Richmond, Richmond, Victoria, Australia
| | - JinJing Liao
- Department of Infrastructure Engineering, The University of Melbourne, Parkville, Victoria, Australia
| | - Darpan Shidid
- RMIT Centre for Additive Manufacture, RMIT University, Melbourne, Victoria, Australia
| | - Lihai Zhang
- Department of Infrastructure Engineering, The University of Melbourne, Parkville, Victoria, Australia.
| |
Collapse
|
7
|
Abstract
Fracture healing is a complex, multistep process that is highly sensitive to mechanical signaling. To optimize repair, surgeons prescribe immediate weight-bearing as-tolerated within 24 hours after surgical fixation; however, this recommendation is based on anecdotal evidence and assessment of bulk healing outcomes (e.g., callus size, bone volume, etc.). Given challenges in accurately characterizing the mechanical environment and the ever-changing properties of the regenerate, the principles governing mechanical regulation of repair, including their cell and molecular basis, are not yet well defined. However, the use of mechanobiological rodent models, and their relatively large genetic toolbox, combined with recent advances in imaging approaches and single-cell analyses is improving our understanding of the bone microenvironment in response to loading. This review describes the identification and characterization of distinct cell populations involved in bone healing and highlights the most recent findings on mechanical regulation of bone homeostasis and repair with an emphasis on osteo-angio coupling. A discussion on aging and its impact on bone mechanoresponsiveness emphasizes the need for novel mechanotherapeutics that can re-sensitize skeletal stem and progenitor cells to physical rehabilitation protocols.
Collapse
Affiliation(s)
- Tareq Anani
- Department of Orthopedic Surgery, New York University Langone Health, New York, NY 10010, USA
| | - Alesha B Castillo
- Department of Orthopedic Surgery, New York University Langone Health, New York, NY 10010, USA; Department of Biomedical Engineering, Tandon School of Engineering, New York University, New York, NY 11201, USA; Department of Veterans Affairs, New York Harbor Healthcare System, Manhattan Campus, New York, NY 10010, USA.
| |
Collapse
|
8
|
Quan K, Xu Q, Zhu M, Liu X, Dai M. Analysis of Risk Factors for Non-union After Surgery for Limb Fractures: A Case-Control Study of 669 Subjects. Front Surg 2022; 8:754150. [PMID: 34970588 PMCID: PMC8712717 DOI: 10.3389/fsurg.2021.754150] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Accepted: 11/22/2021] [Indexed: 11/13/2022] Open
Abstract
Objective: The purpose of this study was to analyze the risk factors for limb fracture non-union in order to improve non-union prevention and early detection. Methods: A total of 223 patients with non-union after surgery for limb fractures performed at our institution from January 2005 to June 2017 were included as the case group, while a computer-generated random list was created to select 446 patients with successful bone healing after surgery for limb fractures who were treated during the same period as the control group, thus achieving a ratio of 1:2. The medical records of these patients were reviewed retrospectively. Age, sex, body mass index, obesity, smoking, alcohol, diabetes, hypertension, osteoporosis, fracture type, multiple fractures, non-steroidal anti-inflammatory drugs (NSAIDs) use, delayed weight bearing, internal fixation failure, and infection data were analyzed and compared between the two groups. A multivariate logistic regression model was constructed to determine relevant factors associated with non-union. Results: After comparison between two groups by univariate analysis and multivariate logistic regression, we found some risk factors associated that osteoporosis (odds ratio [OR] = 3.16, 95% confidence interval [CI]: 2.05–4.89, p < 0.001), open fracture (OR = 2.71, 95%CI: 1.72–4.27, p < 0.001), NSAIDs use (OR = 2.04, 95%CI: 1.24–3.37, p = 0.005), delayed weight bearing (OR = 1.72, 95%CI: 1.08–2.74, p = 0.023), failed internal fixation (OR = 5.93, 95%CI: 2.85–12.36, p < 0.001), and infection (OR = 6.77, 95%CI: 2.92–15.69, p < 0.001) were independent risk factors for non-union after surgery for limb fractures. Conclusions: Osteoporosis, open fracture type, NSAIDs use, delayed weight bearing, failed internal fixation, and infection were found to be the main causes of bone non-union; clinicians should, therefore, take targeted measures to intervene in high-risk groups early.
Collapse
Affiliation(s)
- Kun Quan
- Department of Orthopedics, The First Affiliated Hospital of Nanchang University, Artificial Joints Engineering and Technology Research Center of Jiangxi Province, Nanchang, China
| | - Qiang Xu
- Department of Orthopedics, The First Affiliated Hospital of Nanchang University, Artificial Joints Engineering and Technology Research Center of Jiangxi Province, Nanchang, China
| | - Meisong Zhu
- Department of Orthopedics, The First Affiliated Hospital of Nanchang University, Artificial Joints Engineering and Technology Research Center of Jiangxi Province, Nanchang, China
| | - Xuqiang Liu
- Department of Orthopedics, The First Affiliated Hospital of Nanchang University, Artificial Joints Engineering and Technology Research Center of Jiangxi Province, Nanchang, China
| | - Min Dai
- Department of Orthopedics, The First Affiliated Hospital of Nanchang University, Artificial Joints Engineering and Technology Research Center of Jiangxi Province, Nanchang, China
| |
Collapse
|
9
|
Qi W, Feng X, Zhang T, Wu H, Fang C, Leung F. Development and validation of a modularized external fixator for generating standardized fracture healing micromotions in rats. Bone Joint Res 2021; 10:714-722. [PMID: 34747191 PMCID: PMC8636178 DOI: 10.1302/2046-3758.1011.bjr-2021-0028.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Aims To fully verify the reliability and reproducibility of an experimental method in generating standardized micromotion for the rat femur fracture model. Methods A modularized experimental device has been developed that allows rat models to be used instead of large animal models, with the aim of reducing systematic errors and time and money constraints on grouping. The bench test was used to determine the difference between the measured and set values of the micromotion produced by this device under different simulated loading weights. The displacement of the fixator under different loading conditions was measured by compression tests, which was used to simulate the unexpected micromotion caused by the rat’s ambulation. In vivo preliminary experiments with a small sample size were used to test the feasibility and effectiveness of the whole experimental scheme and surgical scheme. Results The bench test showed that a weight loading < 500 g did not affect the operation of experimental device. The compression test demonstrated that the stiffness of the device was sufficient to keep the uncontrollable motion between fracture ends, resulting from the rat’s daily activities, within 1% strain. In vivo results on 15 rats prove that the device works reliably, without overburdening the experimental animals, and provides standardized micromotion reproductively at the fracture site according to the set parameters. Conclusion Our device was able to investigate the effect of micromotion parameters on fracture healing by generating standardized micromotion to small animal models. Cite this article: Bone Joint Res 2021;10(11):714–722.
Collapse
Affiliation(s)
- Weichen Qi
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Xiaoreng Feng
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China.,Yangjiang People's Hospital, Yangjiang, China
| | - Teng Zhang
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Hao Wu
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Christian Fang
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, The University of Hong Kong, Hong Kong, China
| | - Frankie Leung
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, The University of Hong Kong, Hong Kong, China
| |
Collapse
|
10
|
Shi J, Xiao Y, Wu M, Guan J. [Research on the nature of micromovement and the biomechanical staging of fracture healing]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:1205-1211. [PMID: 34523290 DOI: 10.7507/1002-1892.202103050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To explore the nature of micromovement and the biomechanical staging of fracture healing. Methods Through literature review and theoretical analysis, the difference in micromovement research was taken as the breakthrough point to try to provide a new understanding of the role of micromovement and the mechanical working mode in the process of fracture healing. Results The process of fracture healing is the process of callus generation and connection. The micromovement is the key to start the growth of callus, and the total amount of callus should be matched with the size of the fracture space. The strain at the fracture end is the key to determine the callus connection. The strain that can be tolerated by different tissues in the fracture healing process will limit the micromovement. According to this, the fracture healing process can be divided into the initiation period, perfusion period, contradiction period, connection period, and physiological period, i.e., the biomechanical staging of fracture healing. Conclusion Biomechanical staging of fracture healing incorporates important mechanical parameters affecting fracture healing and introduces the concepts of time and space, which helps to understand the role of biomechanics, and its significance needs further clinical test and exploration.
Collapse
Affiliation(s)
- Jinyou Shi
- Department of Orthopaedics, the First Affiliated Hospital, Bengbu Medical College, Bengbu Anhui, 233000, P.R.China
| | - Yuzhou Xiao
- Department of Orthopaedics, the First Affiliated Hospital, Bengbu Medical College, Bengbu Anhui, 233000, P.R.China
| | - Min Wu
- Department of Orthopaedics, the First Affiliated Hospital, Bengbu Medical College, Bengbu Anhui, 233000, P.R.China
| | - Jianzhong Guan
- Department of Orthopaedics, the First Affiliated Hospital, Bengbu Medical College, Bengbu Anhui, 233000, P.R.China
| |
Collapse
|
11
|
McKissack HM, Viner GC, McMurtrie JT, Alexander BK, Jha AJ, Wilson JT, Shah AB. Does Insurance Status Affect Access to Care Among Ankle Fracture Patients? An Institutional Retrospective Study. J Foot Ankle Surg 2021; 60:520-522. [PMID: 33546990 DOI: 10.1053/j.jfas.2020.10.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 09/23/2020] [Accepted: 10/02/2020] [Indexed: 02/03/2023]
Abstract
Delayed access to care for patients with ankle fractures may increase risk of complications, particularly if surgical management is warranted. Medicaid is a state and federal insurance program in place for those with low income, which has previously been associated with delayed access to care among patients with ACL tears and total hip arthroplasties. The purpose of this study is to assess whether patient insurance status affects access to care for ankle fracture patients, using data from a single institution. A retrospective cohort study (N = 311 patients)was performed on individuals that underwent open reduction and internal fixation for an ankle fracture between years 01/2008 and 12/2018. Patients with polytraumatic injuries, open injuries, Medicare, no insurance, indigent/charity insurance, self-pay, or whose insurance information was not available were excluded. Time from date of injury to date of surgery, injury to first visit, and first visit to surgery was compared between patients with private insurance and Medicaid. Average time from injury to first appointment was 1.2 days and 6.2 days for privately insured and Medicaid patients, respectively (p < .001). Average time from injury to surgery was 8.3 days and 16.1 days for privately insured and Medicaid patients, respectively (p < .001). Patients enrolled in Medicaid have significantly delayed access to care compared to those with private insurance. For ankle fracture patients this is a critical healing time, and delayed care may result in increased costs, increased utilization of healthcare resources, higher complication rates, and poorer patient outcomes.
Collapse
Affiliation(s)
- Haley M McKissack
- Research Fellow, Department of Orthopaedic Surgery, University of Alabama, Birmingham, Birmingham, AL
| | - Gean C Viner
- Research Fellow, Department of Orthopaedic Surgery, University of Alabama, Birmingham, Birmingham, AL
| | - James T McMurtrie
- Resident Physcian, Department of Orthopaedic Surgery, University of Alabama, Birmingham, Birmingham, AL
| | - Bradley K Alexander
- Research Fellow, Department of Orthopaedic Surgery, University of Alabama, Birmingham, Birmingham, AL
| | - Aaradhana J Jha
- Research Fellow, Department of Orthopaedic Surgery, University of Alabama, Birmingham, Birmingham, AL
| | - John T Wilson
- Research Fellow, Department of Orthopaedic Surgery, University of Alabama, Birmingham, Birmingham, AL
| | - Ashish B Shah
- Associate Professor, Department of Orthopaedic Surgery, University of Alabama, Birmingham, Birmingham, AL.
| |
Collapse
|
12
|
Bony callus stiffness indirectly evaluated by the axial load-share ratio in vivo as a guide to removing a monolateral external fixator safely. INTERNATIONAL ORTHOPAEDICS 2021; 45:3015-3023. [PMID: 34164731 PMCID: PMC8626363 DOI: 10.1007/s00264-021-05116-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 06/11/2021] [Indexed: 11/06/2022]
Abstract
Purpose As the monolateral external fixator is increasingly used in trauma-control and definitive management for high-energy long bone fractures, timing the fixator removal remains a challenge for surgeons. The purpose of this study was to determine the feasibility and effectiveness of the bony callus stiffness indirectly evaluated by the axial load-share ratio in vivo as a guide to removing a monolateral external fixator safely. Methods A total of 131 patients with tibial shaft fractures treated by the monolateral external fixator in our institution were collected from January 2013 to July 2019. In group I, the fixators were removed based on the clinical and radiological assessment only by the treating surgeon. As for group II, the axial load-share (LS) ratio test was accomplished by another medical team without the knowledge of the clinical results. The external fixator was removed when the mechanical test outcome (LS ratio < 10%) was consistent with the conclusion drawn from the clinical and radiological assessment (bone union achieved) by the treating surgeon. Results There was no statistical significance in demographic data between the two groups (P > 0.05). In group I, four patients suffered refracture (the refracture rate was 7.7%) after fixator removal and were successfully treated by an intramedullary nail. In group II, 71 patients underwent fixator removal after the first mechanical test, and another eight patients terminated the external fixation after the second test. None of the 79 patients in group II suffered refracture (the refracture rate was 0%). There was statistical significance in the refracture rate between the two groups (P < 0.05). Conclusion The bony callus stiffness indirectly evaluated by the axial load-share ratio in vivo using the additional circular frame components is an effectively quantitative indicator to complement the clinical assessment of fracture healing in a monolateral external fixation treatment. Removal of the monolateral external fixator is safe when the axial load-share ratio dropped below 10%.
Collapse
|
13
|
Barcik J, Epari DR. Can Optimizing the Mechanical Environment Deliver a Clinically Significant Reduction in Fracture Healing Time? Biomedicines 2021; 9:691. [PMID: 34207370 PMCID: PMC8234230 DOI: 10.3390/biomedicines9060691] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 06/14/2021] [Accepted: 06/16/2021] [Indexed: 11/17/2022] Open
Abstract
The impact of the local mechanical environment in the fracture gap on the bone healing process has been extensively investigated. Whilst it is widely accepted that mechanical stimulation is integral to callus formation and secondary bone healing, treatment strategies that aim to harness that potential are rare. In fact, the current clinical practice with an initially partial or non-weight-bearing approach appears to contradict the findings from animal experiments that early mechanical stimulation is critical. Therefore, we posed the question as to whether optimizing the mechanical environment over the course of healing can deliver a clinically significant reduction in fracture healing time. In reviewing the evidence from pre-clinical studies that investigate the influence of mechanics on bone healing, we formulate a hypothesis for the stimulation protocol which has the potential to shorten healing time. The protocol involves confining stimulation predominantly to the proliferative phase of healing and including adequate rest periods between applications of stimulation.
Collapse
Affiliation(s)
- Jan Barcik
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
- Bulgarian Academy of Sciences, Institute of Metal Science “Acad. A. Balevski”, Shipchenski prohod 67, 1574 Sofia, Bulgaria
| | - Devakara R. Epari
- Institute of Health and Biomedical Innovation, Queensland University of Technology, George Street 2, Brisbane, QLD 4000, Australia;
| |
Collapse
|
14
|
Hente RW, Perren SM. Tissue deformation controlling fracture healing. J Biomech 2021; 125:110576. [PMID: 34171609 DOI: 10.1016/j.jbiomech.2021.110576] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 05/31/2021] [Accepted: 06/02/2021] [Indexed: 12/01/2022]
Abstract
To achieve optimal flexibility in biological internal fracture fixation two questions require clarification: which biomechanical parameter controls healing and what are the boundary conditions thereof? Fracture movement interacts with callus and local stress and strain are influencing the reaction of the tissue cells. A linear gradient of strain was created inside a sheep tibia osteotomy using an active external fixator. The effect of different amounts of strain applied at 10 stimulation cycles/day on the occurrence of callus and on enabling osseous connection of the fragments was evaluated using micro-radiology to determine the amount of calcified new bone formation and its quality of gap bridging. A strong relation between level of strain and amount of callus was observed. Depending on the strain level different pattern of connections were seen. At the lowest investigated gap strain level of about 7% direct connection of the fragments within the gap occurred. Beyond 13% the callus only connected indirectly outside the gap. At over 36% callus did not connect the fragments anymore comparable to a situation in hypertrophic non-unions. The observed strong relation between interfragmentary strain and reduced osseous bridging may support the hypothesis that the elongation at rupture of connecting tissue plays an important role defining the upper limit for solid bridging. In planning fracture treatment, the amount of fracture mobility resulting in interfragmentary strain may play a crucial role to achieve solid healing.
Collapse
Affiliation(s)
- R W Hente
- AO Research Institute Davos CH 7260, Switzerland; University of Regensburg, Regensburg D 93042, Germany; Kliniken Südostbayern AG, Bad Reichenhall D 83435, Germany.
| | - S M Perren
- AO Research Institute Davos CH 7260, Switzerland; IHBI Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
15
|
Augat P, Hollensteiner M, von Rüden C. The role of mechanical stimulation in the enhancement of bone healing. Injury 2021; 52 Suppl 2:S78-S83. [PMID: 33041020 DOI: 10.1016/j.injury.2020.10.009] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 09/22/2020] [Accepted: 10/01/2020] [Indexed: 02/02/2023]
Abstract
The biomechanical environment plays a dominant role in the process of fracture repair. Mechanical signals control biological activities at the fracture site, regulate the formation and proliferation of different cell types, and are responsible for the formation of connective tissues and the consolidation of the fractured bone. The mechanobiology at the fracture site can be easily manipulated by the design and configuration of the fracture fixation construct and by the loading of the extremity (weight-bearing prescription). Depending on the choice of fracture fixation, the healing response can be directed towards direct healing or towards indirect healing through callus formation. This manuscript summarizes the evidence from experimental studies and clinical observations on the effect of mechanical manipulation on the healing response. Parameters like fracture gap size, interfragmentary movement, interfragmentary strain, and axial and shear deformation will be explored with respect to their respective effects on fracture repair. Also, the role of externally applied movement on the potential enhancement on the fracture repair process will be explored. Factors like fracture gap size, type and amplitude of the mechanical deformation as well as the loading history and its timing will be discussed.
Collapse
Affiliation(s)
- Peter Augat
- Institute for Biomechanics, Berufsgenossenschaftliche Unfallklinik Murnau, Murnau, Germany; Institute for Biomechanics Paracelsus Medical University Salzburg, Salzburg, Austria.
| | - Marianne Hollensteiner
- Institute for Biomechanics, Berufsgenossenschaftliche Unfallklinik Murnau, Murnau, Germany; Institute for Biomechanics Paracelsus Medical University Salzburg, Salzburg, Austria
| | - Christian von Rüden
- Institute for Biomechanics Paracelsus Medical University Salzburg, Salzburg, Austria; Department of Trauma Surgery, Berufsgenossenschaftliche Unfallklinik Murnau, Murnau, Germany
| |
Collapse
|
16
|
Glatt V, Samchukov M, Cherkashin A, Iobst C. Reverse Dynamization Accelerates Bone-Healing in a Large-Animal Osteotomy Model. J Bone Joint Surg Am 2021; 103:257-263. [PMID: 33315696 DOI: 10.2106/jbjs.20.00380] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Reverse dynamization is a mechanical manipulation regimen designed to accelerate bone-healing and remodeling. It is based on the hypothesis that a fracture that is initially stabilized less rigidly allows micromotion to encourage initial cartilaginous callus formation. Once substantial callus has formed, the stabilization should then be converted to a rigid configuration to prevent the disruption of neovascularization. The aim of the present study was to investigate whether bone-healing can be accelerated using a regimen of reverse dynamization in a large-animal osteotomy model. METHODS Transverse 2-mm tibial osteotomies were created in 18 goats, stabilized using circular external fixation, and divided into groups of 6 goats each: static fixation (rigid fixation), dynamic fixation (continuous micromotion using dynamizers), and reverse dynamization (initial micromotion using dynamizers followed by rigid fixation at 3 weeks postoperatively). Healing was assessed with the use of radiographs, micro-computed tomography, and mechanical testing. RESULTS Radiographic evaluation showed earlier and more robust callus formation in the dynamic fixation and reverse dynamization groups compared with the static fixation group. After 8 weeks of treatment, the reverse dynamization group had reduced callus size, less bone volume, higher bone mineral density, and no evidence of radiolucent lines compared with the static fixation and dynamic fixation groups. This appearance is characteristic of advanced remodeling, returning closest to the values of intact bone. Moreover, the tibiae in the reverse dynamization group were significantly stronger in torsion compared with those in the static fixation and dynamic fixation groups. CONCLUSIONS These findings confirmed that tibial osteotomies under reverse dynamization healed faster, healed objectively better, and were considerably stronger, all suggesting an accelerated healing and remodeling process. CLINICAL RELEVANCE This study demonstrates that the concept of reverse dynamization challenges the current understanding regarding the optimal fixation stability necessary to maximize the regenerative capacity of bone-healing. When reverse dynamization is employed in the clinical setting, it may be able to improve the treatment of fractures by reducing the time to union and potentially lowering the risk of delayed union and nonunion.
Collapse
Affiliation(s)
- Vaida Glatt
- Department of Orthopedic Surgery, University of Texas Health Science Center, San Antonio, Texas
| | - Mikhail Samchukov
- The Center for Excellence in Limb Lengthening & Reconstruction, Texas Scottish Rite Hospital for Children, Dallas, Texas.,Department of Orthopedic Surgery, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Alexander Cherkashin
- The Center for Excellence in Limb Lengthening & Reconstruction, Texas Scottish Rite Hospital for Children, Dallas, Texas.,Department of Orthopedic Surgery, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Christopher Iobst
- Center for Limb Lengthening and Reconstruction, Nationwide Children's Hospital, Columbus, Ohio
| |
Collapse
|
17
|
Thiart G, Herbert C, Sivarasu S, Gasant S, Laubscher M. Influence of Different Connecting Rod Configurations on the Stability of the Ilizarov/TSF Frame: A Biomechanical Study. Strategies Trauma Limb Reconstr 2020; 15:23-27. [PMID: 33363637 PMCID: PMC7744669 DOI: 10.5005/jp-journals-10080-1447] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Aim The Ilizarov external fixator (IEF) is frequently used in trauma and elective orthopaedics. Many of its biomechanical variables (ring size, wire diameter, wire number, half pins vs wires, etc.) and their influence on stability and stiffness have been investigated. There is, however, a paucity in the literature regarding the influence of the connecting rod numbers and configurations between the rings on IEF stability. The primary aim of this biomechanical study was to compare the stability between four- and three-rod IEF configurations. Secondarily to assess the difference in stability between symmetrical and asymmetrical spacing of the IEF rods. Materials and methods A custom jig was designed to facilitate mounting of a basic two-ring IEF in a hydraulic press. Controlled centre and off-centre (thus simulated bending) axial loading was then applied across the frame. The configurations were loaded up to 4,000 N. The frame deformation was plotted and the data were then analysed and interpreted. Results Negligible differences were observed between different four- and three-rod configurations as long as the applied force at the loading point (LP) was within the area of support (AOS) created by the rods. The different four-rod constructs were always more stable than the three-rod constructs during bending. Conclusion There is comparable stiffness between a four-rod and a three-rod IEF construct as long as the LP is within the AOS created by the rods. A four-rod IEF is stiffer than a three-rod IEF in bending. Clinical significance This study will possibly change some paradigms regarding the planning and application of IEFs by Orthopaedics Traumatologists and Reconstruction Surgeons. How to cite this article Thiart G, Herbert C, Sivarasu S, et al. Influence of Different Connecting Rod Configurations on the Stability of the Ilizarov/TSF Frame: A Biomechanical Study. Strategies Trauma Limb Reconstr 2020;15(1):23–27.
Collapse
Affiliation(s)
- Gerhard Thiart
- Department of Orthopaedics, Worcester Provincial Hospital, Worcester, Western Cape, South Africa; Department of Orthopaedic Research, Groote Schuur Hospital Unit, University of Cape Town, Cape Town, Western Cape, South Africa
| | - Christopher Herbert
- Department of Biomechanical Engineering, University of Cape Town, Cape Town, Western Cape, South Africa
| | - Sudesh Sivarasu
- Department of Biomechanical Engineering, University of Cape Town, Cape Town, Western Cape, South Africa
| | - Saadiq Gasant
- Department of Biomechanical Engineering, University of Cape Town, Cape Town, Western Cape, South Africa
| | - Maritz Laubscher
- Department of Orthopaedic Research, Groote Schuur Hospital Unit, University of Cape Town, Cape Town, Western Cape, South Africa
| |
Collapse
|
18
|
Barcik J, Ernst M, Dlaska CE, Drenchev L, Zeiter S, Epari DR, Windolf M. Programable Active Fixator System for Systematic In Vivo Investigation of Bone Healing Processes. SENSORS (BASEL, SWITZERLAND) 2020; 21:E17. [PMID: 33375087 PMCID: PMC7792812 DOI: 10.3390/s21010017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 12/15/2020] [Accepted: 12/19/2020] [Indexed: 12/19/2022]
Abstract
This manuscript introduces a programable active bone fixator system that enables systematic investigation of bone healing processes in a sheep animal model. In contrast to previous systems, this solution combines the ability to precisely control the mechanical conditions acting within a fracture with continuous monitoring of the healing progression and autonomous operation of the system throughout the experiment. The active fixator system was implemented on a double osteotomy model that shields the experimental fracture from the influence of the animal's functional loading. A force sensor was integrated into the fixator to continuously measure stiffness of the repair tissue as an indicator for healing progression. A dedicated control unit was developed that allows programing of different loading protocols which are later executed autonomously by the active fixator. To verify the feasibility of the system, it was implanted in two sheep with different loading protocols, mimicking immediate and delayed weight-bearing, respectively. The implanted devices operated according to the programmed protocols and delivered seamless data over the whole course of the experiment. The in vivo trial confirmed the feasibility of the system. Hence, it can be applied in further preclinical studies to better understand the influence of mechanical conditions on fracture healing.
Collapse
Affiliation(s)
- Jan Barcik
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (M.E.); (S.Z.); (M.W.)
- Bulgarian Academy of Sciences, Institute of Metal Science ‘Acad. A. Balevski’, Shipchenski prohod 67, 1574 Sofia, Bulgaria;
| | - Manuela Ernst
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (M.E.); (S.Z.); (M.W.)
| | - Constantin E. Dlaska
- Orthopaedic Research Institute of Queensland, 7 Turner Street, Townsville, QLD 4812, Australia;
| | - Ludmil Drenchev
- Bulgarian Academy of Sciences, Institute of Metal Science ‘Acad. A. Balevski’, Shipchenski prohod 67, 1574 Sofia, Bulgaria;
| | - Stephan Zeiter
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (M.E.); (S.Z.); (M.W.)
| | - Devakara R. Epari
- Institute of Health and Biomedical Innovation, Queensland University of Technology, George Street 2, Brisbane City, QLD 4000, Australia;
| | - Markus Windolf
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland; (M.E.); (S.Z.); (M.W.)
| |
Collapse
|
19
|
3D Biomimetic Porous Titanium (Ti 6Al 4V ELI) Scaffolds for Large Bone Critical Defect Reconstruction: An Experimental Study in Sheep. Animals (Basel) 2020; 10:ani10081389. [PMID: 32796533 PMCID: PMC7459697 DOI: 10.3390/ani10081389] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 08/07/2020] [Accepted: 08/08/2020] [Indexed: 01/10/2023] Open
Abstract
Simple Summary The authors propose a new reconstructive technique that proved to be suitable to reach this purpose through the use of a custom-made biomimetic porous titanium scaffold. An in vivo study was undertaken where a complete critical defect was experimentally created in the diaphysis of the right tibia of twelve sheep and replaced with a five-centimeter porous scaffold of electron beam melting (EBM)-manufactured titanium alloy or a porous hydroxyapatite scaffold. Our results show that EBM-formed titanium devices, if used to repair critical bone defects in a large animal model, can guarantee immediate body weight-bearing, a rapid functional recovery, and a good osseointegration. The porous hydroxyapatite scaffolds proved to be not suitable in this model of large bone defect due to their known poor mechanical properties. Abstract The main goal in the treatment of large bone defects is to guarantee a rapid loading of the affected limb. In this paper, the authors proposed a new reconstructive technique that proved to be suitable to reach this purpose through the use of a custom-made biomimetic porous titanium scaffold. An in vivo study was undertaken where a complete critical defect was experimentally created in the diaphysis of the right tibia of twelve sheep and replaced with a five-centimeter porous scaffold of electron beam melting (EBM)-sintered titanium alloy (EBM group n = 6) or a porous hydroxyapatite scaffold (CONTROL group, n = 6). After surgery, the sheep were allowed to move freely in the barns. The outcome was monitored for up to 12 months by periodical X-ray and clinical examination. All animals in the CONTROL group were euthanized for humane reasons within the first month after surgery due to the onset of plate bending due to mechanical overload. Nine months after surgery, X-ray imaging showed the complete integration of the titanium implant in the tibia diaphysis and remodeling of the periosteal callus, with a well-defined cortical bone. At 12 months, sheep were euthanized, and the tibia were harvested and subjected to histological analysis. This showed bone tissue formations with bone trabeculae bridging titanium trabeculae, evidencing an optimal tissue-metal interaction. Our results show that EBM-sintered titanium devices, if used to repair critical bone defects in a large animal model, can guarantee immediate body weight-bearing, a rapid functional recovery, and a good osseointegration. The porous hydroxyapatite scaffolds proved to be not suitable in this model of large bone defect due to their known poor mechanical properties.
Collapse
|
20
|
McDermott AM, Herberg S, Mason DE, Collins JM, Pearson HB, Dawahare JH, Tang R, Patwa AN, Grinstaff MW, Kelly DJ, Alsberg E, Boerckel JD. Recapitulating bone development through engineered mesenchymal condensations and mechanical cues for tissue regeneration. Sci Transl Med 2020; 11:11/495/eaav7756. [PMID: 31167930 DOI: 10.1126/scitranslmed.aav7756] [Citation(s) in RCA: 106] [Impact Index Per Article: 26.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Accepted: 05/13/2019] [Indexed: 01/08/2023]
Abstract
Large bone defects cannot form a callus and exhibit high complication rates even with the best treatment strategies available. Tissue engineering approaches often use scaffolds designed to match the properties of mature bone. However, natural fracture healing is most efficient when it recapitulates development, forming bone via a cartilage intermediate (endochondral ossification). Because mechanical forces are critical for proper endochondral bone development and fracture repair, we hypothesized that recapitulating developmental mechanical forces would be essential for large bone defect regeneration in rats. Here, we engineered mesenchymal condensations that mimic the cellular organization and lineage progression of the early limb bud in response to local transforming growth factor-β1 presentation from incorporated gelatin microspheres. We then controlled mechanical loading in vivo by dynamically tuning fixator compliance. Mechanical loading enhanced mesenchymal condensation-induced endochondral bone formation in vivo, restoring functional bone properties when load initiation was delayed to week 4 after defect formation. Live cell transplantation produced zonal human cartilage and primary spongiosa mimetic of the native growth plate, whereas condensation devitalization before transplantation abrogated bone formation. Mechanical loading induced regeneration comparable to high-dose bone morphogenetic protein-2 delivery, but without heterotopic bone formation and with order-of-magnitude greater mechanosensitivity. In vitro, mechanical loading promoted chondrogenesis and up-regulated pericellular matrix deposition and angiogenic gene expression. In vivo, mechanical loading regulated cartilage formation and neovascular invasion, dependent on load timing. This study establishes mechanical cues as key regulators of endochondral bone defect regeneration and provides a paradigm for recapitulating developmental programs for tissue engineering.
Collapse
Affiliation(s)
- Anna M McDermott
- Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.,Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN 46556, USA.,Department of Mechanical Engineering, Trinity Center for Bioengineering, Trinity College Dublin, Dublin D02 PN40, Ireland
| | - Samuel Herberg
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Devon E Mason
- Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.,Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Joseph M Collins
- Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.,Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN 46556, USA.,Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Hope B Pearson
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN 46556, USA
| | - James H Dawahare
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Rui Tang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Amit N Patwa
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Mark W Grinstaff
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Daniel J Kelly
- Department of Mechanical Engineering, Trinity Center for Bioengineering, Trinity College Dublin, Dublin D02 PN40, Ireland
| | - Eben Alsberg
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA. .,Department of Orthopaedic Surgery, Case Western Reserve University, Cleveland, OH 44106, USA.,National Center for Regenerative Medicine, Division of General Medical Sciences, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Joel D Boerckel
- Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA. .,Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN 46556, USA.,Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
21
|
Hoit G, Bonyun M, Nauth A. Hardware considerations in infection and nonunion management: When and how to revise the fixation. OTA Int 2020; 3:e055. [PMID: 33937680 PMCID: PMC8081462 DOI: 10.1097/oi9.0000000000000055] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Accepted: 11/09/2019] [Indexed: 06/12/2023]
Abstract
The occurrence of both nonunion and fracture-related infection provides challenges for both the patient and the treating orthopaedic surgeon, with the potential need for complex reconstructive procedures to achieve union and/or eradicate infection. In addition to addressing the multiple different factors that often contribute to nonunion, surgeons are often forced to deal with difficult hardware issues at the time of revision surgery including infected hardware, loose or failing hardware, malaligned hardware, or inappropriate hardware constructs. This article reviews common causes of nonunions with emphasis on infection management and provides indications and techniques for hardware removal in the context of an algorithmic approach to nonunion management with illustrative case examples.
Collapse
Affiliation(s)
- Graeme Hoit
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto
| | - Marissa Bonyun
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto
| | - Aaron Nauth
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto
- Department of Orthopaedic Surgery, St. Michaels Hospital, Toronto, ON, Canada
| |
Collapse
|
22
|
Abstract
OBJECTIVES The stiffness of locking plates provide increased stability for early fracture healing but may limit late interfragmentary motion (IFM) necessary for secondary bone healing. An ideal plating construct would provide early rigidity and late flexibility to optimize bone healing. A novel screw plate construct utilizing locking screws with a degradable polymer locking mechanism is a dynamic option. METHODS Conventional locked plating constructs (group A) were compared with locking screws with a threaded degradable polymer collar before (group B) and after polymer dissolution (group C). Monotonic axial compression, monotonic torsion, cyclic axial load to failure, and IFM at the near and far cortices were tested on synthetic bone models. RESULTS One-way analysis of variance and post hoc Tukey-Kramer testing demonstrated similar axial stiffness in group A (873 ± 146 N/mm) and B (694 ± 314 N/mm) but significantly less stiffness in group C (379 ± 59 N/mm; F(2,15) = 9.12, P = 0.003). Groups A and B also had similar IFM, but group C had significantly increased IFM at both the near (F(2, 15) = 48.66, P = 2.76E-07) and far (F(2, 15) = 11.78, P = 0.0008) cortices. In cyclic axial load to failure, group A (1593 ± 233 N) and B (1277 ± 141 N) were again similar, but group C was significantly less (912 ± 256 N; F(2, 15) = 15.00, P = 0.0003). All failures were above the 500-N threshold seen in typical weight-bearing restrictions for fracture care. Torsional stiffness demonstrated significant differences between all groups (F(2, 15) = 106.64, P = 1.4E-09). CONCLUSIONS Use of locking plates with a degradable polymer collar show potential for in vitro construct dynamization. Future in vivo studies are warranted to assess performance under combined loading and the effects of decreasing construct stiffness during the course of bony healing.
Collapse
|
23
|
Borgiani E, Figge C, Kruck B, Willie BM, Duda GN, Checa S. Age-Related Changes in the Mechanical Regulation of Bone Healing Are Explained by Altered Cellular Mechanoresponse. J Bone Miner Res 2019; 34:1923-1937. [PMID: 31121071 DOI: 10.1002/jbmr.3801] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 04/03/2019] [Accepted: 05/18/2019] [Indexed: 02/05/2023]
Abstract
Increasing age is associated with a reduced bone regeneration potential and increased risk of morbidities and mortality. A reduced bone formation response to mechanical loading has been shown with aging, and it remains unknown if the interplay between aging and mechanical stimuli during regeneration is similar to adaptation. We used a combined in vivo/in silico approach to investigate age-related alterations in the mechanical regulation of bone healing and identified the relative impact of altered cellular function on tissue patterns during the regenerative cascade. To modulate the mechanical environment, femoral osteotomies in adult and elderly mice were stabilized using either a rigid or a semirigid external fixator, and the course of healing was evaluated using histomorphometric and micro-CT analyses at 7, 14, and 21 days post-surgery. Computer models were developed to investigate the influence of the local mechanical environment within the callus on tissue formation patterns. The models aimed to identify the key processes at the cellular level that alter the mechanical regulation of healing with aging. Fifteen age-related biological alterations were investigated on two levels (adult and elderly) with a design of experiments setup. We show a reduced response to changes in fixation stability with age, which could be explained by reduced cellular mechanoresponse, simulated as alteration of the ranges of mechanical stimuli driving mesenchymal stem cell differentiation. Cellular mechanoresponse has been so far widely ignored as a therapeutic target in aged patients. Our data hint to mechanotherapeutics as a potential treatment to enhance bone healing in the elderly. © 2019 American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Edoardo Borgiani
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Berlin, Germany
| | - Christine Figge
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Bettina Kruck
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Bettina M Willie
- Research Centre, Shriners Hospital for Children-Canada, Department of Pediatric Surgery, McGill University, Montreal, Canada
| | - Georg N Duda
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Berlin, Germany
| | - Sara Checa
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Berlin, Germany
| |
Collapse
|
24
|
Schreivogel S, Kuchibhotla V, Knaus P, Duda GN, Petersen A. Load-induced osteogenic differentiation of mesenchymal stromal cells is caused by mechano-regulated autocrine signaling. J Tissue Eng Regen Med 2019; 13:1992-2008. [PMID: 31359634 DOI: 10.1002/term.2948] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 06/28/2019] [Accepted: 07/19/2019] [Indexed: 12/12/2022]
Abstract
Mechanical boundary conditions critically influence the bone healing process. In this context, previous in vitro studies have demonstrated that cyclic mechanical compression alters migration and triggers osteogenesis of mesenchymal stromal cells (MSC), both processes being relevant to healing. However, it remains unclear whether this mechanosensitivity is a direct consequence of cyclic compression, an indirect effect of altered supply or a specific modulation of autocrine bone morphogenetic protein (BMP) signaling. Here, we investigate the influence of cyclic mechanical compression (ε = 5% and 10%, f = 1 Hz) on human bone marrow MSC (hBMSC) migration and osteogenic differentiation in a 3D biomaterial scaffold, an in vitro system mimicking the mechanical environment of the early bone healing phase. The open-porous architecture of the scaffold ensured sufficient supply even without cyclic compression, minimizing load-associated supply alterations. Furthermore, a large culture medium volume in relation to the cell number diminished autocrine signaling. Migration of hBMSCs was significantly downregulated under cyclic compression. Surprisingly, a decrease in migration was not associated with increased osteogenic differentiation of hBMSCs, as the expression of RUNX2 and osteocalcin decreased. In contrast, BMP2 expression was significantly upregulated. Enabling autocrine stimulation by increasing the cell-to-medium ratio in the bioreactor finally resulted in a significant upregulation of RUNX2 in response to cyclic compression, which could be reversed by rhNoggin treatment. The results indicate that osteogenesis is promoted by cyclic compression when cells condition their environment with BMP. Our findings highlight the importance of mutual interactions between mechanical forces and BMP signaling in controlling osteogenic differentiation.
Collapse
Affiliation(s)
- Sophie Schreivogel
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany
- Berlin-Brandenburg Center and School for Regenerative Therapies, Berlin, Germany
| | | | - Petra Knaus
- Berlin-Brandenburg Center and School for Regenerative Therapies, Berlin, Germany
- Institute for Chemistry and Biochemistry, Freie Universität Berlin, Berlin, Germany
| | - Georg N Duda
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany
- Berlin-Brandenburg Center and School for Regenerative Therapies, Berlin, Germany
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Ansgar Petersen
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany
- Berlin-Brandenburg Center and School for Regenerative Therapies, Berlin, Germany
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
25
|
Herberg S, McDermott AM, Dang PN, Alt DS, Tang R, Dawahare JH, Varghai D, Shin JY, McMillan A, Dikina AD, He F, Lee YB, Cheng Y, Umemori K, Wong PC, Park H, Boerckel JD, Alsberg E. Combinatorial morphogenetic and mechanical cues to mimic bone development for defect repair. SCIENCE ADVANCES 2019; 5:eaax2476. [PMID: 31489377 PMCID: PMC6713501 DOI: 10.1126/sciadv.aax2476] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Accepted: 07/19/2019] [Indexed: 05/28/2023]
Abstract
Endochondral ossification during long bone development and natural fracture healing initiates by mesenchymal cell condensation, directed by local morphogen signals and mechanical cues. Here, we aimed to mimic development for regeneration of large bone defects. We hypothesized that engineered human mesenchymal condensations presenting transforming growth factor-β1 (TGF-β1) and/or bone morphogenetic protein-2 (BMP-2) from encapsulated microparticles promotes endochondral defect regeneration contingent on in vivo mechanical cues. Mesenchymal condensations induced bone formation dependent on morphogen presentation, with BMP-2 + TGF-β1 fully restoring mechanical function. Delayed in vivo ambulatory loading significantly enhanced the bone formation rate in the dual morphogen group. In vitro, BMP-2 or BMP-2 + TGF-β1 initiated robust endochondral lineage commitment. In vivo, however, extensive cartilage formation was evident predominantly in the BMP-2 + TGF-β1 group, enhanced by mechanical loading. Together, this study demonstrates a biomimetic template for recapitulating developmental morphogenic and mechanical cues in vivo for tissue engineering.
Collapse
Affiliation(s)
- S. Herberg
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - A. M. McDermott
- Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania
- Philadelphia, PA, USA
| | - P. N. Dang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - D. S. Alt
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - R. Tang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | | | - D. Varghai
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - J.-Y. Shin
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - A. McMillan
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - A. D. Dikina
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - F. He
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Y. B. Lee
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Y. Cheng
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - K. Umemori
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - P. C. Wong
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, USA
| | - H. Park
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - J. D. Boerckel
- Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania
- Philadelphia, PA, USA
- School of Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei, Taiwan
| | - E. Alsberg
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
- Department of Orthopaedic Surgery, Case Western Reserve University, Cleveland, OH, USA
| |
Collapse
|
26
|
Characterization of compliance to weight-bearing protocols and patient weight-bearing behavior during the recovery period in lower extremity fractures: a pilot study. CURRENT ORTHOPAEDIC PRACTICE 2019. [DOI: 10.1097/bco.0000000000000773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
27
|
Rational design of gelatin/nanohydroxyapatite cryogel scaffolds for bone regeneration by introducing chemical and physical cues to enhance osteogenesis of bone marrow mesenchymal stem cells. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 104:109855. [PMID: 31500067 DOI: 10.1016/j.msec.2019.109855] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 05/20/2019] [Accepted: 06/01/2019] [Indexed: 02/04/2023]
Abstract
Identification of key components in the chemical and physical milieu for directing osteogenesis is a requirement in the investigation of tissue engineering scaffolds for advancement of bone regeneration. In this study, we engineered different gelatin-based cryogels and studied the effect of nanohydroxyapatite (nHAP) and crosslinking agents on scaffold properties and its osteogenic response towards bone marrow stem cells (BMSCs). The cryogels examined are 5% gelatin and 5% gelatin/2.5% nHAP, crosslinked either with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) or glutaraldehyde (GA). We confirmed that nHAP or the crosslinking agent has no effects on scaffold pore size and porosity. Nonetheless, incorporation of nHAP increased mechanical strength, swelling ratio and degree of crosslinking, but decreased degradation rate. Cryogels crosslinked with EDC showed faster degradation and promoted osteogenic differentiation of BMSCs while those prepared from GA crosslinking promoted proliferation of BMSCs. Furthermore, osteogenic differentiation was always enhanced in the presence of nHAP irrespective of the culture medium (normal or osteogenic) used but osteogenic medium always provide a higher extent of osteogenic differentiation. Employing gelatin/nHAP cryogel crosslinked by EDC in a bioreactor for dynamic culture of BMSCs, cyclic compressive mechanical simulation was found to be beneficial for both cell proliferation and osteogenic differentiation. However, the optimum conditions for osteogenic differentiation and cell proliferation were found at 30% and 60% strain, respectively. We thus demonstrated that osteogenic differentiation of BMSCs could be tuned by taking advantages of chemical cues generated from scaffold chemistry or physical cues generated from dynamic cell culture in vitro. Furthermore, by combining the best cryogel preparation and in vitro cell culture condition for osteogenesis, we successfully employed in vitro cultured cryogel/BMSCs constructs for repair of rabbit critical-sized cranial bone defects.
Collapse
|
28
|
Braun BJ, Veith NT, Herath SC, Hell R, Rollmann M, Orth M, Holstein JH, Pohlemann T. [A new continuous gait analysis system for ankle fracture aftercare]. Unfallchirurg 2019; 121:293-299. [PMID: 28235983 DOI: 10.1007/s00113-017-0332-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Correct aftercare following lower extremity fractures remains a controversial issue. Reliable, clinically applicable weight-bearing recommendations have not yet been defined. The aim of the current study was to establish a new gait analysis insole during physical therapy aftercare of ankle fractures to test patients' continuous, long-term compliance to partial weight-bearing restrictions and investigate whether patients can estimate their weight-bearing compliance. MATERIALS AND METHODS The postoperative gait of 14 patients after operative treatment of Weber B-type ankle fractures was monitored continuously for six weeks (OpenGO, Moticon GmbH, Munich). All patients were instructed and trained by physical therapists on how to maintain partial weight-bearing for this time. Discontinuous (three, six and twelve weeks) clinical (patient questionnaire, visual analogue pain score [VAS]) and radiographic controls were performed. RESULTS Despite the set weight-bearing limits, individual ranges for overall weight-bearing (range 5-107% of the contralateral side) and patient activity (range 0-366 min/day) could be shown. A good correlation between weight-bearing and pain was seen (rs = -0.68; p = <0.0001). Patients significantly underestimated their weight-bearing time over the set limit (2.3 ± 1.4 min/day vs. real: 12.6 ± 5.9 min/day; p < 0.01). CONCLUSIONS Standardized aftercare protocols and repeated training alone cannot ensure compliance to postoperative partial weight-bearing. Patients unconsciously increased weight-bearing based on their pain level. This study shows that new, individual and possibly technology-assisted weight-bearing regimes are needed. The introduced measuring device is feasible to monitor and steer patient weight-bearing during future studies.
Collapse
Affiliation(s)
- B J Braun
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421, Homburg, Deutschland.
| | - N T Veith
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421, Homburg, Deutschland
| | - S C Herath
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421, Homburg, Deutschland
| | - R Hell
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421, Homburg, Deutschland
| | - M Rollmann
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421, Homburg, Deutschland
| | - M Orth
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421, Homburg, Deutschland
| | - J H Holstein
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421, Homburg, Deutschland
| | - T Pohlemann
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes, Kirrberger Str., 66421, Homburg, Deutschland
| |
Collapse
|
29
|
Histomorphometric Analysis of Callus Formation Stimulated by Axial Dynamisation in a Standardised Ovine Osteotomy Model. BIOMED RESEARCH INTERNATIONAL 2019; 2019:4250940. [PMID: 30891456 PMCID: PMC6390264 DOI: 10.1155/2019/4250940] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 12/07/2018] [Accepted: 01/16/2019] [Indexed: 12/30/2022]
Abstract
The cyclic axial dynamisation of a stabilised fracture is intended to promote callus formation and bone healing. Most studies focused on biomechanical properties or the quantity of new bone formation. Far less is known about the quality of newly formed callus tissues, such as tissue distribution and arrangement within the callus. The aim of this current study was to investigate the effect of cyclic, axial dynamisation on the quantity and quality of callus in an established delayed fracture healing model. In 41 sheep transverse osteotomies with a gap size of 3 mm were stabilised with a unilateral external fixator. In 32 of these, fracture ends were axially stimulated with displacement amplitudes of 0.8 mm, 0.4 mm, 0.2 mm, or 0.0 mm, respectively, for six weeks. In the remaining 9 sheep of the control group, an additional external fixator was mounted to achieve almost total rigidity. Animal material originating from a past animal experiment was reanalysed in this study. Histological thin-ground sections were histomorphometrically analysed regarding the histological structure and composition of the defect region. A slight tendency towards an increase in size of total callus area, area of new bone (nB.Ar), and cartilage (Cg.Ar) was detected with increasing displacement amplitudes compared to the control group. At the anterior callus side nB.Ar and Cg.Ar were significantly larger than at the posterior side in all groups independent of treatment. Regarding the quality of callus, areas of very compact bone were predominant in the treatment groups whereas in the control group a slight shift to more porous bone was observed. No difference of callus compactness was observed between the anterior and the posterior side. The established method to assess the local compactness of callus areas is a useful tool to quantitatively determine the spatial distribution of new bone tissue within the callus. The application of this method in combination with biomechanical testing might reveal interesting relations between tissue distribution and bone strength that, with traditional histomorphometry, cannot be identified.
Collapse
|
30
|
Grivas KN, Vavva MG, Polyzos D, Carlier A, Geris L, Van Oosterwyck H, Fotiadis DI. Effect of ultrasound on bone fracture healing: A computational mechanobioregulatory model. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:1048. [PMID: 30823826 DOI: 10.1121/1.5089221] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2018] [Accepted: 01/12/2019] [Indexed: 06/09/2023]
Abstract
Bone healing process is a complicated phenomenon regulated by biochemical and mechanical signals. Experimental studies have shown that ultrasound (US) accelerates bone ossification and has a multiple influence on cell differentiation and angiogenesis. In a recent work of the authors, a bioregulatory model for providing bone-healing predictions was addressed, taking into account for the first time the salutary effect of US on the involved angiogenesis. In the present work, a mechanobioregulatory model of bone solidification under the US presence incorporating also the mechanical environment on the regeneration process, which is known to affect cellular processes, is presented. An iterative procedure is adopted, where the finite element method is employed to compute the mechanical stimuli at the linear elastic phases of the poroelastic callus region and a coupled system of partial differential equations to simulate the enhancement by the US cell angiogenesis process and thus the oxygen concentration in the fractured area. Numerical simulations with and without the presence of US that illustrate the influence of progenitor cells' origin in the healing pattern and the healing rate and simultaneously demonstrate the salutary effect of US on bone repair are presented and discussed.
Collapse
Affiliation(s)
- Konstantinos N Grivas
- Department of Mechanical Engineering and Aeronautics, University of Patras, GR 26500, Patras, Greece
| | - Maria G Vavva
- Department of Mechanical Engineering and Aeronautics, University of Patras, GR 26500, Patras, Greece
| | - Demosthenes Polyzos
- Department of Mechanical Engineering and Aeronautics, University of Patras, GR 26500, Patras, Greece
| | - Aurélie Carlier
- Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C-PB 2419, B-3001, Leuven, Belgium
| | - Liesbet Geris
- Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C-PB 2419, B-3001, Leuven, Belgium
| | - Hans Van Oosterwyck
- Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C-PB 2419, B-3001, Leuven, Belgium
| | - Dimitrios I Fotiadis
- Department of Materials Science and Engineering, University of Ioannina, GR 45110, Ioannina, Greece
| |
Collapse
|
31
|
Dissaux C, Wagner D, George D, Spingarn C, Rémond Y. Mechanical impairment on alveolar bone graft: A literature review. J Craniomaxillofac Surg 2019; 47:149-157. [DOI: 10.1016/j.jcms.2018.10.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 10/08/2018] [Accepted: 10/30/2018] [Indexed: 10/27/2022] Open
|
32
|
Baker CE, Moore-Lotridge SN, Hysong AA, Posey SL, Robinette JP, Blum DM, Benvenuti MA, Cole HA, Egawa S, Okawa A, Saito M, McCarthy JR, Nyman JS, Yuasa M, Schoenecker JG. Bone Fracture Acute Phase Response-A Unifying Theory of Fracture Repair: Clinical and Scientific Implications. Clin Rev Bone Miner Metab 2018; 16:142-158. [PMID: 30930699 PMCID: PMC6404386 DOI: 10.1007/s12018-018-9256-x] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Bone fractures create five problems that must be resolved: bleeding, risk of infection, hypoxia, disproportionate strain, and inability to bear weight. There have been enormous advancements in our understanding of the molecular mechanisms that resolve these problems after fractures, and in best clinical practices of repairing fractures. We put forth a modern, comprehensive model of fracture repair that synthesizes the literature on the biology and biomechanics of fracture repair to address the primary problems of fractures. This updated model is a framework for both fracture management and future studies aimed at understanding and treating this complex process. This model is based upon the fracture acute phase response (APR), which encompasses the molecular mechanisms that respond to injury. The APR is divided into sequential stages of "survival" and "repair." Early in convalescence, during "survival," bleeding and infection are resolved by collaborative efforts of the hemostatic and inflammatory pathways. Later, in "repair," avascular and biomechanically insufficient bone is replaced by a variable combination of intramembranous and endochondral ossification. Progression to repair cannot occur until survival has been ensured. A disproportionate APR-either insufficient or exuberant-leads to complications of survival (hemorrhage, thrombosis, systemic inflammatory response syndrome, infection, death) and/or repair (delayed- or non-union). The type of ossification utilized for fracture repair is dependent on the relative amounts of strain and vascularity in the fracture microenvironment, but any failure along this process can disrupt or delay fracture healing and result in a similar non-union. Therefore, incomplete understanding of the principles herein can result in mismanagement of fracture care or application of hardware that interferes with fracture repair. This unifying model of fracture repair not only informs clinicians how their interventions fit within the framework of normal biological healing but also instructs investigators about the critical variables and outputs to assess during a study of fracture repair.
Collapse
Affiliation(s)
- Courtney E Baker
- 1Department of Orthopaedics, Mayo Clinic, 200 1st Ave SW, Rochester, MN 55903 USA
| | - Stephanie N Moore-Lotridge
- 2Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. South, Suite 4200 MCE, South Tower, Nashville, TN 37232 USA.,3Department of Pathology, Microbiology, and Immunology, Vanderbilt University Medical Center, 1161 21st Ave. South, Nashville, TN 37232 USA
| | - Alexander A Hysong
- 4Vanderbilt University School of Medicine, 1161 21st Ave S, #D3300, Nashville, TN 37232 USA
| | - Samuel L Posey
- 4Vanderbilt University School of Medicine, 1161 21st Ave S, #D3300, Nashville, TN 37232 USA
| | - J Patton Robinette
- 4Vanderbilt University School of Medicine, 1161 21st Ave S, #D3300, Nashville, TN 37232 USA
| | - Deke M Blum
- 4Vanderbilt University School of Medicine, 1161 21st Ave S, #D3300, Nashville, TN 37232 USA
| | - Michael A Benvenuti
- 2Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. South, Suite 4200 MCE, South Tower, Nashville, TN 37232 USA
| | - Heather A Cole
- 2Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. South, Suite 4200 MCE, South Tower, Nashville, TN 37232 USA
| | - Satoru Egawa
- 2Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. South, Suite 4200 MCE, South Tower, Nashville, TN 37232 USA.,5Department of Orthopaedic Surgery, Tokyo Medical and Dental University, Yushima Bunkyo Ward, Tokyo, 113-8519 Japan
| | - Atsushi Okawa
- 5Department of Orthopaedic Surgery, Tokyo Medical and Dental University, Yushima Bunkyo Ward, Tokyo, 113-8519 Japan
| | - Masanori Saito
- 2Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. South, Suite 4200 MCE, South Tower, Nashville, TN 37232 USA.,5Department of Orthopaedic Surgery, Tokyo Medical and Dental University, Yushima Bunkyo Ward, Tokyo, 113-8519 Japan
| | - Jason R McCarthy
- Masonic Research Institute, 2150 Bleecker St, Utica, NY 13501 USA
| | - Jeffry S Nyman
- 2Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. South, Suite 4200 MCE, South Tower, Nashville, TN 37232 USA.,7Department of Biomedical Engineering, Vanderbilt University, PMB 351631, 2301 Vanderbilt Place, Nashville, TN 37235 USA.,Department of Veterans Affairs, Tennessee Valley Health Care System, F-519 VA Acre Building, 1210 24th Ave. South, Nashville, TN 37232 USA
| | - Masato Yuasa
- 2Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. South, Suite 4200 MCE, South Tower, Nashville, TN 37232 USA.,5Department of Orthopaedic Surgery, Tokyo Medical and Dental University, Yushima Bunkyo Ward, Tokyo, 113-8519 Japan
| | - Jonathan G Schoenecker
- 2Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. South, Suite 4200 MCE, South Tower, Nashville, TN 37232 USA.,3Department of Pathology, Microbiology, and Immunology, Vanderbilt University Medical Center, 1161 21st Ave. South, Nashville, TN 37232 USA.,9Department of Pharmacology, Vanderbilt University, 2200 Pierce Ave, Robinson Research Building, Nashville, TN 37232 USA.,10Department of Pediatrics, Vanderbilt University Medical Center, 4202 Doctor's Office Tower, 2200 Children's Way, Nashville, TN 37232 USA
| |
Collapse
|
33
|
Dingemans SA, Sintenie FW, de Jong VM, Luitse JSK, Schepers T. Fixation Methods for Calcaneus Fractures: A Systematic Review of Biomechanical Studies Using Cadaver Specimens. J Foot Ankle Surg 2018; 57:116-122. [PMID: 29129315 DOI: 10.1053/j.jfas.2017.05.042] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Indexed: 02/03/2023]
Abstract
Calcaneal fractures are notoriously difficult to treat and wound complications occur often. However, owing to the rare nature of these fractures, clinical trials on this subject are lacking. Thus, biomechanical studies form a viable source of information on this subject. With our systematic review of biomechanical studies, we aimed to provide an overview of all the techniques available and guide clinicians in their choice of method of fracture fixation. A literature search was conducted using 3 online databases to find biomechanical studies investigating methods of fixation for calcaneal fractures. A total of 14 studies investigating 237 specimens were identified. Large diversity was found in the tested fixation methods and in the test setups used. None of the studies found a significant difference in favor of any of the fixation methods. All tested methods provided a biomechanically stable fixation. All the investigated methods of fixation for calcaneal fractures seem to be biomechanically sufficient. No clear benefit was found for locking plates in the fixation of calcaneal fractures; however, a subtle mechanical superiority might exist compared with nonlocking plates in the case of fractures in osteoporotic bone. Several of the techniques tested would be suitable for a minimal invasive approach. These should be investigated further in clinical trials.
Collapse
Affiliation(s)
- Siem A Dingemans
- Resident General Surgery, Trauma Unit, Academic Medical Center, Amsterdam, The Netherlands
| | - Floris W Sintenie
- Medical Student, Trauma Unit, Academic Medical Center, Amsterdam, The Netherlands
| | - Vincent M de Jong
- Traumasurgeon, Trauma Unit, Academic Medical Center, Amsterdam, The Netherlands
| | - Jan S K Luitse
- Traumasurgeon, Trauma Unit, Academic Medical Center, Amsterdam, The Netherlands
| | - Tim Schepers
- Traumasurgeon, Trauma Unit, Academic Medical Center, Amsterdam, The Netherlands.
| |
Collapse
|
34
|
Tibial Fracture Nonunion and Time to Healing After Reamed Intramedullary Nailing: Risk Factors Based on a Single-Center Review of 1003 Patients. J Orthop Trauma 2018; 32:e263-e269. [PMID: 29664881 DOI: 10.1097/bot.0000000000001173] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To determine factors associated with nonunion of adult tibial fractures. DESIGN Retrospective review with data collection for logistic regression and survival analysis. SETTING Scottish Level I trauma center, 1985-2007. PATIENTS During this period, 1590 adult tibial fractures were treated by reamed nailing and 1003 fractures met all inclusion criteria for the chosen analysis. INTERVENTION Reamed intramedullary nailing. MAIN OUTCOME MEASURES Record of nonunion diagnosis and final union time with characteristics, including age, gender, closed or open injury, OTA/AO classification, Gustilo classification, fasciotomy, infection, polytrauma, smoking, and injury severity score. RESULTS The overall nonunion rate was 12%, and median time to healing was 18 weeks. Age significantly influenced nonunion, with middle-aged patients at highest risk. Both fracture type (closed/open) and morphology (OTA/AO classification) significantly influenced nonunion risk and time to union. Among closed injuries, the highest nonunion rate was for OTA/AO type B fractures (15%). Among open injuries, the highest nonunion rate was for OTA/AO type C (61%). Both compartment syndrome and smoking did not significantly influence nonunion risk but did significantly extend time to union. CONCLUSIONS Injury characteristics including fracture morphology and severity of soft tissue injury were strong predictors of compromised fracture healing. Age also influenced nonunion risk in an unexpected way, with highest rates in the middle decades of adulthood. Future studies should consider the possibility of similar age-related effects and clinical studies should seek to identify explanations for why this may arise, including both physiological and socio-behavioral factors. LEVEL OF EVIDENCE Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
35
|
Komrakova M, Fiebig J, Hoffmann DB, Krischek C, Lehmann W, Stuermer KM, Sehmisch S. The Advantages of Bilateral Osteotomy Over Unilateral Osteotomy for Osteoporotic Bone Healing. Calcif Tissue Int 2018; 103:80-94. [PMID: 29352329 DOI: 10.1007/s00223-018-0392-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Accepted: 01/11/2018] [Indexed: 11/28/2022]
Abstract
Most models of osteoporotic bone fractures are performed unilaterally (UL). We investigated healing of tibia osteotomy performed either UL or bilaterally (BL) in ovariectomized rats. Behavior of animals and muscle structure were assessed. Three-month-old female Sprague-Dawley rats were ovariectomized (n = 32). After 10 weeks, half the rats underwent UL osteotomy of tibia metaphysis (right limb) with plate osteosynthesis. The other rats were osteotomized BL. Half of the rats in each group received either standard pain treatment with carprofen (5 mg/kg body weight (BW), 1x/day for 2 days) or carprofen and buprenorphine (5 mg/kg BW, 1x/day and 0.03 mg/kg BW, 2x/day for 5 days) after osteotomy. The UL rats started to load the injured limb from day 27 ± 9; BL rats did this from day 4 ± 4 onward. The UL rats more frequently loaded only one hind limb; BL rats more often loaded both hind limbs. Osteotomy was not bridged in 20% of UL rats and in 4% of BL rats. Callus volume and bone volume fraction were lower in UL group. Weight and fiber size of UL-intact limb muscles were enhanced, compared to the osteotomized limb and those in BL group. Most of the other parameters which assess physiology, activity, body posture, head, or coat were not different. The effect of two pain therapies was not significant on any variable studied. Welfare of the animals was acceptable in all rats. In UL rats, bone healing was delayed. The more advanced healing in BL rats suggested a positive effect of earlier loading. In studies on bone healing, it is advisable to perform BL osteotomy.
Collapse
Affiliation(s)
- M Komrakova
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center, Robert-Koch 40, 37075, Goettingen, Germany.
| | - J Fiebig
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center, Robert-Koch 40, 37075, Goettingen, Germany
| | - D B Hoffmann
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center, Robert-Koch 40, 37075, Goettingen, Germany
| | - C Krischek
- Department of Animal Sciences, University of Goettingen, Albrecht-Thaer-Weg 3, 37075, Goettingen, Germany
- Institute of Food Quality and Safety, Foundation University of Veterinary Medicine, Bischofsholer Damm 15, 30173, Hanover, Germany
| | - W Lehmann
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center, Robert-Koch 40, 37075, Goettingen, Germany
| | - K M Stuermer
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center, Robert-Koch 40, 37075, Goettingen, Germany
| | - S Sehmisch
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center, Robert-Koch 40, 37075, Goettingen, Germany
| |
Collapse
|
36
|
Tufekci P, Tavakoli A, Dlaska C, Neumann M, Shanker M, Saifzadeh S, Steck R, Schuetz M, Epari D. Early mechanical stimulation only permits timely bone healing in sheep. J Orthop Res 2018; 36:1790-1796. [PMID: 29159911 DOI: 10.1002/jor.23812] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Accepted: 11/11/2017] [Indexed: 02/04/2023]
Abstract
Bone fracture healing is sensitive to the fixation stability. However, it is unclear which phases of healing are mechano-sensitive and if mechanical stimulation is required throughout repair. In this study, a novel bone defect model, which isolates an experimental fracture from functional loading, was applied in sheep to investigate if stimulation limited to the early proliferative phase is sufficient for bone healing. An active fixator controlled motion in the fracture. Animals of the control group were unstimulated. In the physiological-like group, 1 mm axial compressive movements were applied between day 5 and 21, thereafter the movements were decreased in weekly increments and stopped after 6 weeks. In the early stimulatory group, the movements were stopped after 3 weeks. The experimental fractures were evaluated with mechanical and micro-computed tomography methods after 9 weeks healing. The callus strength of the stimulated fractures (physiological-like and early stimulatory) was greater than the unstimulated control group. The control group was characterized by minimal external callus formation and a lack of bone bridging at 9 weeks. In contrast, the stimulated groups exhibited advanced healing with solid bone formation across the defect. This was confirmed quantitatively by a lower bone volume in the control group compared to the stimulated groups.The novel experimental model permits the application of a well-defined load history to an experimental bone fracture. The poor healing observed in the control group is consistent with under-stimulation. This study has shown early mechanical stimulation only is sufficient for a timely healing outcome. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1790-1796, 2018.
Collapse
Affiliation(s)
- Pelin Tufekci
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), 60 Musk Avenue, Kelvin Grove, Brisbane, 4059, Queensland, Australia
| | - Aramesh Tavakoli
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), 60 Musk Avenue, Kelvin Grove, Brisbane, 4059, Queensland, Australia
| | - Constantin Dlaska
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), 60 Musk Avenue, Kelvin Grove, Brisbane, 4059, Queensland, Australia
| | - Mirjam Neumann
- Trauma Service, Princess Alexandra Hospital, Brisbane, Australia
| | - Mihir Shanker
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), 60 Musk Avenue, Kelvin Grove, Brisbane, 4059, Queensland, Australia
| | - Siamak Saifzadeh
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), 60 Musk Avenue, Kelvin Grove, Brisbane, 4059, Queensland, Australia
| | - Roland Steck
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), 60 Musk Avenue, Kelvin Grove, Brisbane, 4059, Queensland, Australia
| | - Michael Schuetz
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), 60 Musk Avenue, Kelvin Grove, Brisbane, 4059, Queensland, Australia.,Trauma Service, Princess Alexandra Hospital, Brisbane, Australia
| | - Devakar Epari
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), 60 Musk Avenue, Kelvin Grove, Brisbane, 4059, Queensland, Australia
| |
Collapse
|
37
|
Houben IB, Raaben M, Van Basten Batenburg M, Blokhuis TJ. Delay in weight bearing in surgically treated tibial shaft fractures is associated with impaired healing: a cohort analysis of 166 tibial fractures. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 28:1429-1436. [PMID: 29633016 PMCID: PMC6132919 DOI: 10.1007/s00590-018-2190-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 03/21/2018] [Indexed: 02/07/2023]
Abstract
Background The relation between timing of weight bearing after a fracture and the healing outcome is yet to be established, thereby limiting the implementation of a possibly beneficial effect for our patients. The current study was undertaken to determine the effect of timing of weight bearing after a surgically treated tibial shaft fracture. Materials and methods Surgically treated diaphyseal tibial fractures were retrospectively studied between 2007 and 2015. The timing of initial weight bearing (IWB) was analysed as a predictor for impaired healing in a multivariate regression. Results Totally, 166 diaphyseal tibial fractures were included, 86 cases with impaired healing and 80 with normal healing. The mean age was 38.7 years (range 16–89). The mean time until IWB was significantly shorter in the normal fracture healing group (2.6 vs 7.4 weeks, p < 0.001). Correlation analysis yielded four possible confounders: infection requiring surgical intervention, fracture type, fasciotomy and open fractures. Logistic regression identified IWB as an independent predictor for impaired healing with an odds ratio of 1.13 per week delay (95% CI 1.03–1.25). Conclusions Delay in initial weight bearing is independently associated with impaired fracture healing in surgically treated tibial shaft fractures. Unlike other factors such as fracture type or soft tissue condition, early resumption of weight bearing can be influenced by the treating physician and this factor therefore has a direct clinical relevance. This study indicates that early resumption of weight bearing should be the treatment goal in fracture fixation. Level of evidence 3b.
Collapse
Affiliation(s)
- I B Houben
- Department of Surgery, University Medical Centre Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
| | - M Raaben
- Department of Surgery, University Medical Centre Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - M Van Basten Batenburg
- Department of Surgery, University Medical Centre Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - T J Blokhuis
- Department of Surgery, Maastricht University Medical Centre, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands
| |
Collapse
|
38
|
Oravec D, Kim W, Flynn MJ, Yeni YN. The relationship of whole human vertebral body creep to geometric, microstructural, and material properties. J Biomech 2018; 73:92-98. [PMID: 29599039 DOI: 10.1016/j.jbiomech.2018.03.021] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 02/02/2018] [Accepted: 03/09/2018] [Indexed: 12/15/2022]
Abstract
Creep, the time dependent deformation of a structure under load, is an important viscoelastic property of bone and may play a role in the development of permanent deformity of the vertebrae in vivo leading to clinically observable spinal fractures. To date, creep properties and their relationship to geometric, microstructural, and material properties have not been described in isolated human vertebral bodies. In this study, a range of image-based measures of vertebral bone geometry, bone mass, microarchitecture and mineralization were examined in multiple regression models in an effort to understand their contribution to creep behavior. Several variables, such as measures of mineralization heterogeneity, average bone density, and connectivity density persistently appeared as significant effects in multiple regression models (adjusted r2: 0.17-0.56). Although further work is needed to identify additional tissue properties to fully describe the portion of variability not explained by these models, these data are expected to help understand mechanisms underlying creep and improve prediction of vertebral deformities that eventually progress to a clinically observable fracture.
Collapse
Affiliation(s)
- Daniel Oravec
- Bone and Joint Center, Henry Ford Hospital, Detroit, MI, United States
| | - Woong Kim
- Bone and Joint Center, Henry Ford Hospital, Detroit, MI, United States
| | - Michael J Flynn
- Department of Radiology, Henry Ford Hospital, Detroit, MI, United States
| | - Yener N Yeni
- Bone and Joint Center, Henry Ford Hospital, Detroit, MI, United States.
| |
Collapse
|
39
|
Liu C, Carrera R, Flamini V, Kenny L, Cabahug-Zuckerman P, George BM, Hunter D, Liu B, Singh G, Leucht P, Mann KA, Helms JA, Castillo AB. Effects of mechanical loading on cortical defect repair using a novel mechanobiological model of bone healing. Bone 2018; 108:145-155. [PMID: 29305998 PMCID: PMC8262576 DOI: 10.1016/j.bone.2017.12.027] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2015] [Revised: 12/20/2017] [Accepted: 12/29/2017] [Indexed: 12/30/2022]
Abstract
Mechanical loading is an important aspect of post-surgical fracture care. The timing of load application relative to the injury event may differentially regulate repair depending on the stage of healing. Here, we used a novel mechanobiological model of cortical defect repair that offers several advantages including its technical simplicity and spatially confined repair program, making effects of both physical and biological interventions more easily assessed. Using this model, we showed that daily loading (5N peak load, 2Hz, 60 cycles, 4 consecutive days) during hematoma consolidation and inflammation disrupted the injury site and activated cartilage formation on the periosteal surface adjacent to the defect. We also showed that daily loading during the matrix deposition phase enhanced both bone and cartilage formation at the defect site, while loading during the remodeling phase resulted in an enlarged woven bone regenerate. All loading regimens resulted in abundant cellular proliferation throughout the regenerate and fibrous tissue formation directly above the defect demonstrating that all phases of cortical defect healing are sensitive to physical stimulation. Stress was concentrated at the edges of the defect during exogenous loading, and finite element (FE)-modeled longitudinal strain (εzz) values along the anterior and posterior borders of the defect (~2200με) was an order of magnitude larger than strain values on the proximal and distal borders (~50-100με). It is concluded that loading during the early stages of repair may impede stabilization of the injury site important for early bone matrix deposition, whereas loading while matrix deposition and remodeling are ongoing may enhance stabilization through the formation of additional cartilage and bone.
Collapse
Affiliation(s)
- Chao Liu
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, USA; Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA; Department of Veterans Affairs New York Harbor Healthcare System, New York, NY, USA
| | - Robert Carrera
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Vittoria Flamini
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, USA
| | - Lena Kenny
- Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA
| | - Pamela Cabahug-Zuckerman
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, USA; Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA; Department of Veterans Affairs New York Harbor Healthcare System, New York, NY, USA
| | - Benson M George
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Daniel Hunter
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Bo Liu
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Gurpreet Singh
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Philipp Leucht
- Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA; Department of Cell Biology, New York University, New York, NY, USA
| | - Kenneth A Mann
- Department of Orthopedic Surgery, SUNY Upstate Medical University, Syracuse, NY, USA
| | - Jill A Helms
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Alesha B Castillo
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, USA; Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA; Department of Veterans Affairs New York Harbor Healthcare System, New York, NY, USA.
| |
Collapse
|
40
|
Ex vivo evaluation of the biomechanical effect of varying monocortical screw numbers on a plate-rod canine femoral gap model. Vet Comp Orthop Traumatol 2017; 26:177-85. [DOI: 10.3415/vcot-12-05-0061] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2012] [Accepted: 12/23/2012] [Indexed: 11/17/2022]
Abstract
SummaryObjective: To compare the biomechanical behaviour of plate-rod constructs with varying numbers of monocortical screws applied to an ex vivo canine femoral-gap ostectomy model.Sample population: Twenty Greyhound dog cadaveric femurs.Methods: Bone mineral density (BMD) was assessed with dual x-ray absorptiometry. Bones were assigned to four groups. Bones had a 12-hole 3.5 mm locking compression plate with one bicortical non-locking cortical screw in the most proximal and distal plate holes and an intramedullary Steinmann pin applied across a 20 mm mid-diaphyseal ostectomy. Additionally, one to four monocortical non-locking cortical screws were then placed (Groups 1–4 respectively) in the proximal and distal fragments. Stiffness and axial collapse were determined before and after cyclic axial loading (6000 cycles at 20%, 40%, and 60% of mean bodyweight [total: 18000 cycles]). Constructs subsequently underwent an additional 45000 cycles at 60% of bodyweight (total: 63000 cycles). Loading to failure was then performed and ultimate load and mode of failure recorded.Results: The BMD did not differ significantly between groups. Construct stiffness for group 1 was significantly less than group 4 (p = 0.008). Stiffness showed a linear increase with an increasing number of monocortical screws (p = 0.001). All constructs survived fatigue loading. Load-to-failure was not significantly different between groups. Mean load- to-failure of all groups was >1350N.Clinical relevance: Ex vivo canine large-breed femurs showed adequate stability biomechanically and gradually increasing stiffness with increasing monocortical screw numbers.
Collapse
|
41
|
Meyers N, Schülke J, Ignatius A, Claes L. Novel systems for the application of isolated tensile, compressive, and shearing stimulation of distraction callus tissue. PLoS One 2017; 12:e0189432. [PMID: 29228043 PMCID: PMC5724890 DOI: 10.1371/journal.pone.0189432] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Accepted: 11/25/2017] [Indexed: 12/02/2022] Open
Abstract
Background Distraction osteogenesis is a procedure widely used for the correction of large bone defects. However, a high complication rate persists, likely due to insufficient stability during maturation. Numerical fracture healing models predict bone regeneration under different mechanical conditions allowing fixation stiffness optimization. However, most models apply a linear elastic material law inappropriate for the transient stresses/strains present during limb lengthening or segment transport. They are also often validated using in vivo osteotomy models lacking precise mechanical regulation due to the unavoidable stimulation of secondary interfragmentary motion during ambulation under finitely stiff fixation. Therefore, in order to create a robust numerical model of distraction osteogenesis, it is necessary to both characterize the new tissue’s viscoelasticity during distraction and determine the influence of strictly isolated stimulation in each loading mode (tension, compression, and shear) to account for potential differences in mechanical and histological response. Aim Two electromechanical fixators with integrated load cells were designed to precisely perform and monitor in vivo lateral distraction and isolated stimulation in sheep tibiae using a mobile, hydroxyapatite-coated titanium plate. The novel surgical procedure circumvents osteotomy, eliminating the undesirable and unquantifiable mechanical stimulation during ambulation. Methods After a 10-day post-surgery latency period, two 0.275 mm distraction steps were performed daily for 10 days. The load cell collected data before, during, and after each distraction step and was terminated after no less than one minute from the time of distraction. A 7-day consolidation period separated the distraction phase and 18-day stimulation phase. Stimulation was carried out in isolated tension, compression, or shear while recording force/time data. Each stimulation session consisted of 120 cycles with a magnitude of either 0.1 mm or 0.6 mm in the tension and compression groups and 1.0 mm in the shear group. The animals were euthanized after a 3-day holding period following stimulation. Results Our initial results show that the tissue progressively stiffens and maintains an increasingly large residual traction. The force curves during compressive stimulation show a progressive drift from compression toward tension. We hypothesize that this behavior may be due to the preferential flow of fluid outward from the tissue and a greater resistance to reabsorption during the plate’s return to the starting position.
Collapse
Affiliation(s)
- Nicholaus Meyers
- Institute of Orthopedic Research and Biomechanics, Center of Musculoskeletal Research Ulm, University Hospital Ulm, Ulm, Baden-Württemberg, Germany
- * E-mail:
| | - Julian Schülke
- Institute of Orthopedic Research and Biomechanics, Center of Musculoskeletal Research Ulm, University Hospital Ulm, Ulm, Baden-Württemberg, Germany
| | - Anita Ignatius
- Institute of Orthopedic Research and Biomechanics, Center of Musculoskeletal Research Ulm, University Hospital Ulm, Ulm, Baden-Württemberg, Germany
| | - Lutz Claes
- Institute of Orthopedic Research and Biomechanics, Center of Musculoskeletal Research Ulm, University Hospital Ulm, Ulm, Baden-Württemberg, Germany
| |
Collapse
|
42
|
Ghiasi MS, Chen J, Vaziri A, Rodriguez EK, Nazarian A. Bone fracture healing in mechanobiological modeling: A review of principles and methods. Bone Rep 2017; 6:87-100. [PMID: 28377988 PMCID: PMC5365304 DOI: 10.1016/j.bonr.2017.03.002] [Citation(s) in RCA: 213] [Impact Index Per Article: 30.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2016] [Revised: 02/15/2017] [Accepted: 03/15/2017] [Indexed: 02/07/2023] Open
Abstract
Bone fracture is a very common body injury. The healing process is physiologically complex, involving both biological and mechanical aspects. Following a fracture, cell migration, cell/tissue differentiation, tissue synthesis, and cytokine and growth factor release occur, regulated by the mechanical environment. Over the past decade, bone healing simulation and modeling has been employed to understand its details and mechanisms, to investigate specific clinical questions, and to design healing strategies. The goal of this effort is to review the history and the most recent work in bone healing simulations with an emphasis on both biological and mechanical properties. Therefore, we provide a brief review of the biology of bone fracture repair, followed by an outline of the key growth factors and mechanical factors influencing it. We then compare different methodologies of bone healing simulation, including conceptual modeling (qualitative modeling of bone healing to understand the general mechanisms), biological modeling (considering only the biological factors and processes), and mechanobiological modeling (considering both biological aspects and mechanical environment). Finally we evaluate different components and clinical applications of bone healing simulation such as mechanical stimuli, phases of bone healing, and angiogenesis.
Collapse
Affiliation(s)
- Mohammad S. Ghiasi
- Center for Advanced Orthopaedic Studies, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA, USA
| | - Jason Chen
- Center for Advanced Orthopaedic Studies, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Ashkan Vaziri
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA, USA
| | - Edward K. Rodriguez
- Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Ara Nazarian
- Center for Advanced Orthopaedic Studies, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
- Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
43
|
Dingemans SA, Lodeizen OAP, Goslings JC, Schepers T. Reinforced fixation of distal fibula fractures in elderly patients; A meta-analysis of biomechanical studies. Clin Biomech (Bristol, Avon) 2016; 36:14-20. [PMID: 27195736 DOI: 10.1016/j.clinbiomech.2016.05.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2015] [Revised: 05/03/2016] [Accepted: 05/08/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND There is an increasing incidence of fragility fractures of the ankle in the elderly population. The open reduction and internal fixation of these fractures is challenging, due to reduced bone stock quality as a result of osteoporosis. Biomechanical studies have shown contradicting results using reinforced constructions in the fixation of fibular fractures. We therefore performed a meta-analysis of biomechanical studies on reinforced fixation of distal fibular fractures. METHODS A literature search was conducted utilizing three online databases considering biomechanical testing of different fixation techniques of distal fibular fractures. A meta-analysis was performed on two biomechanical outcome measures; torsional stiffness and torque to failure. FINDINGS In a total number of 13 studies 8 different reinforcement techniques were identified. Of these studies, six compared locked lateral plating with conventional lateral plating. There were no statistically significant differences between the locking and non-locking lateral plate for torque to failure or torsional stiffness. Locked plating strength was independent from bone mineral density in four studies. An antiglide plate proved to be biomechanically superior compared to a lateral plate in one study and to a locked plate in another. INTERPRETATION Locked lateral plates are not biomechanically superior to conventional lateral plates. However the strength of locked plating may be independent of bone mineral density and could make this technique more suitable in the fixation of severe osteoporotic fractures.
Collapse
Affiliation(s)
- Siem A Dingemans
- Trauma Unit, Department of Surgery, Academic Medical Center, Amsterdam, The Netherlands
| | - Olivia A P Lodeizen
- Trauma Unit, Department of Surgery, Academic Medical Center, Amsterdam, The Netherlands
| | - J Carel Goslings
- Trauma Unit, Department of Surgery, Academic Medical Center, Amsterdam, The Netherlands
| | - Tim Schepers
- Trauma Unit, Department of Surgery, Academic Medical Center, Amsterdam, The Netherlands.
| |
Collapse
|
44
|
Bottlang M, Tsai S, Bliven EK, von Rechenberg B, Klein K, Augat P, Henschel J, Fitzpatrick DC, Madey SM. Dynamic Stabilization with Active Locking Plates Delivers Faster, Stronger, and More Symmetric Fracture-Healing. J Bone Joint Surg Am 2016; 98:466-74. [PMID: 26984914 PMCID: PMC4788849 DOI: 10.2106/jbjs.o.00705] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Axial dynamization of fractures can promote healing, and overly stiff fixation can suppress healing. A novel technology, termed active plating, provides controlled axial dynamization by the elastic suspension of locking holes within the plate. This prospective, controlled animal study evaluated the effect of active plates on fracture-healing in an established ovine osteotomy model. We hypothesized that symmetric axial dynamization with active plates stimulates circumferential callus and delivers faster and stronger healing relative to standard locking plates. METHODS Twelve sheep were randomly assigned to receive a standard locking plate or an active locking plate for stabilization of a 3-mm tibial osteotomy gap. The only difference between plates was that locking holes of active plates were elastically suspended, allowing up to 1.5 mm of axial motion at the fracture. Fracture-healing was analyzed weekly on radiographs. After sacrifice at nine weeks postoperatively, callus volume and distribution were assessed by computed tomography. Finally, to determine their strength, healed tibiae and contralateral tibiae were tested in torsion until failure. RESULTS At each follow-up, the active locking plate group had more callus (p < 0.001) than the standard locking plate group. At postoperative week 6, all active locking plate group specimens had bridging callus at the three visible cortices. In standard locking plate group specimens, only 50% of these cortices had bridged. Computed tomography demonstrated that all active locking plate group specimens and one of the six standard locking plate group specimens had developed circumferential callus. Torsion tests after plate removal demonstrated that active locking plate group specimens recovered 81% of their native strength and were 399% stronger than standard locking plate group specimens (p < 0.001), which had recovered only 17% of their native strength. All active locking plate group specimens failed by spiral fracture outside the callus zone, but standard locking plate group specimens fractured through the osteotomy gap. CONCLUSIONS Symmetric axial dynamization with active locking plates stimulates circumferential callus and yields faster and stronger healing than standard locking plates. CLINICAL RELEVANCE The stimulatory effect of controlled motion on fracture-healing by active locking plates has the potential to reduce healing complications and to shorten the time to return to function.
Collapse
Affiliation(s)
- Michael Bottlang
- Portland Biomechanics Laboratory, Legacy Research Institute, Portland, Oregon,E-mail address for M. Bottlang:
| | - Stanley Tsai
- Portland Biomechanics Laboratory, Legacy Research Institute, Portland, Oregon
| | - Emily K. Bliven
- Portland Biomechanics Laboratory, Legacy Research Institute, Portland, Oregon
| | | | - Karina Klein
- Musculoskeletal Research Unit, Vetsuisse Faculty, University of Zürich, Zürich, Switzerland
| | - Peter Augat
- Institute of Biomechanics, Paracelsus Medical University, Salzburg, Austria
| | - Julia Henschel
- Institute of Biomechanics, Trauma Center Murnau, Murnau, Germany
| | | | - Steven M. Madey
- Portland Biomechanics Laboratory, Legacy Research Institute, Portland, Oregon
| |
Collapse
|
45
|
Fountain S, Windolf M, Henkel J, Tavakoli A, Schuetz MA, Hutmacher DW, Epari DR. Monitoring Healing Progression and Characterizing the Mechanical Environment in Preclinical Models for Bone Tissue Engineering. TISSUE ENGINEERING PART B-REVIEWS 2015; 22:47-57. [PMID: 26507933 DOI: 10.1089/ten.teb.2015.0123] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
The treatment of large segmental bone defects remains a significant clinical challenge. Due to limitations surrounding the use of bone grafts, tissue-engineered constructs for the repair of large bone defects could offer an alternative. Before translation of any newly developed tissue engineering (TE) approach to the clinic, efficacy of the treatment must be shown in a validated preclinical large animal model. Currently, biomechanical testing, histology, and microcomputed tomography are performed to assess the quality and quantity of the regenerated bone. However, in vivo monitoring of the progression of healing is seldom performed, which could reveal important information regarding time to restoration of mechanical function and acceleration of regeneration. Furthermore, since the mechanical environment is known to influence bone regeneration, and limb loading of the animals can poorly be controlled, characterizing activity and load history could provide the ability to explain variability in the acquired data sets and potentially outliers based on abnormal loading. Many approaches have been devised to monitor the progression of healing and characterize the mechanical environment in fracture healing studies. In this article, we review previous methods and share results of recent work of our group toward developing and implementing a comprehensive biomechanical monitoring system to study bone regeneration in preclinical TE studies.
Collapse
Affiliation(s)
| | - Markus Windolf
- 1 Queensland University of Technology , Brisbane, Australia .,2 AO Research Institute Davos , Davos, Switzerland
| | - Jan Henkel
- 1 Queensland University of Technology , Brisbane, Australia
| | | | - Michael A Schuetz
- 1 Queensland University of Technology , Brisbane, Australia .,3 Trauma Service, Princess Alexandra Hospital , Brisbane, Australia
| | | | | |
Collapse
|
46
|
The relationship between interfragmentary movement and cell differentiation in early fracture healing under locking plate fixation. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2015; 39:123-33. [DOI: 10.1007/s13246-015-0407-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2015] [Accepted: 11/20/2015] [Indexed: 10/22/2022]
|
47
|
Morgan EF, Lei J. Toward Clinical Application and Molecular Understanding of the Mechanobiology of Bone Healing. Clin Rev Bone Miner Metab 2015. [DOI: 10.1007/s12018-015-9197-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
48
|
Thewlis D, Callary SA, Fraysse F, Solomon LB. Peak loading during walking is not associated with fracture migration following tibial plateau fracture: A preliminary case series. J Orthop Res 2015; 33:1398-406. [PMID: 25820829 DOI: 10.1002/jor.22905] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2014] [Accepted: 03/17/2015] [Indexed: 02/04/2023]
Abstract
Tibial plateau fractures are common, but little evidence exists for their postoperative management, especially when recommending if patients should weight bear at all, partially, or as tolerated. In this study, we describe the loads passing through the fracture construct and the associated fracture migration over the first year following surgery. Nine patients were treated with open reduction and internal fixation and instructed to weight bear as tolerated. Fracture loading and migration were assessed at 2, 12, 26, and 52 weeks postoperative. Fracture loading was calculated as the knee joint reaction force (peak, average, the angle of the force vector, and the point of force application) using gait analysis and an inverse dynamics musculoskeletal model. Fracture migration was assessed using radiostereometric analysis. The fractures were progressively loaded during the rehabilitation phase. The point of application of the load shifted from neutral to medial by week 26 for all patients. Migration during the first postoperative year was within current clinical acceptable limits. The peak load during walking at each time point was not associated with fracture fragment migration and does not appear to exceed the elastic limit of the fracture construct.
Collapse
Affiliation(s)
- Dominic Thewlis
- Alliance for Research in Exercise, Nutrition and Activity, Sansom Institute for Health Research, University of South Australia, Adelaide, SA, Australia.,Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, SA, Australia
| | - Stuart A Callary
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, SA, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
| | - Francois Fraysse
- Alliance for Research in Exercise, Nutrition and Activity, Sansom Institute for Health Research, University of South Australia, Adelaide, SA, Australia
| | - Lucian B Solomon
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, SA, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
| |
Collapse
|
49
|
Zhang J, Wang L, Zhang W, Zhang M, Luo ZP. Synchronization of calcium sulphate cement degradation and new bone formation is improved by external mechanical regulation. J Orthop Res 2015; 33:685-91. [PMID: 25643826 DOI: 10.1002/jor.22839] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Accepted: 01/19/2015] [Indexed: 02/04/2023]
Abstract
A major challenge faced in the bone materials of weight-bearing without internal fixture support is the mismatch of material degradation and new bone formation, leading to weakening or even failure of the overall bony structure. This study demonstrated in the rat femur model that calcium sulphate cement degradation and new bone formation could be better synchronized by external mechanical force. An ascending force in line with calcium sulphate cement degradation could achieve bone healing in 37 days with ultimate load to failure of 87.00 ± 7.30 N, similar to that of intact femur (80.46 ± 2.79 N, p = 0.369). In contrast, the healing process under either a constant force or no force illustrated significant residual defect volumes of 1.47 ± 0.44 and 4.08 ± 0.89 mm(3) (p < 0.001), and weaker ultimate loads to failure of 69.56 ± 4.74 and 59.17 ± 7.48 N, respectively (p < 0.001). Our results suggest that the mechanical regulation approach deserves further investigation and may potentially offer a clinical strategy to improve synchronization.
Collapse
Affiliation(s)
- Jie Zhang
- The 1st Affiliated Hospital of Soochow University, Orthopedic Institute, Soochow University, Suzhou, 215007, China
| | | | | | | | | |
Collapse
|
50
|
Axial strain enhances osteotomy repair with a concomitant increase in connexin43 expression. Bone Res 2015; 3:15007. [PMID: 26273538 PMCID: PMC4411567 DOI: 10.1038/boneres.2015.7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2015] [Revised: 03/03/2015] [Accepted: 03/03/2015] [Indexed: 11/09/2022] Open
Abstract
The mechanical environment is known to influence fracture healing. We speculated that connexin43 (Cx43) gap junctions, which impact skeletal homeostasis, fracture healing and the osteogenic response to mechanical load, may play a role in mediating the response of the healing bone to mechanical strain. Here, we used an established rat fracture model, which uses a 2 mm osteotomy gap stabilized by an external fixator, to examine the impact of various cyclical axial loading protocols (2%, 10%, and 30% strain) on osteotomy healing. We examined the presence of Cx43 in the osteotomy-healing environment and assessed how mechanical strain modulates Cx43 expression patterns in the callus. We demonstrated that increased cyclical axial strain results in increased radiographic and histologic bone formation. In addition, we show by immunohistochemistry that Cx43 is abundantly expressed in the healing callus, with the expression most robust in samples exposed to increased cyclical axial strain. These data are consistent with the concept that an increase in Cx43 expression by mechanical load may be part of the mechanisms by which mechanical forces enhances fracture healing.
Collapse
|