Yuasa A, Uehara S, Ushizawa K, Kodera S, Arai N, Hirata A, Otaka Y. The thermal sensation threshold and its reliability induced by the exposure to 28 GHz millimeter-wave. Front Neurosci 2024; 18:1331416. [PMID: 38476868 PMCID: PMC10927852 DOI: 10.3389/fnins.2024.1331416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 01/26/2024] [Indexed: 03/14/2024] Open
Abstract
The application of 28 GHz millimeter-wave is prevalent owing to the global spread of fifth-generation wireless communication systems. Its thermal effect is a dominant factor which potentially causes pain and tissue damage to the body parts exposed to the millimeter waves. However, the threshold of this thermal sensation, that is, the degree of change in skin temperature from the baseline at which the first subjective response to the thermal effects of the millimeter waves occurs, remains unclear. Here, we investigated the thermal sensation threshold and assessed its reliability when exposed to millimeter waves. Twenty healthy adults were exposed to 28 GHz millimeter-wave on their left middle fingertip at five levels of antenna input power: 0.2, 1.1, 1.6, 2.1, and 3.4 W (incident power density: 27-399 mW/cm2). This measurement session was repeated twice on the same day to evaluate the threshold reliability. The intraclass correlation coefficient (ICC) and Bland-Altman analysis were used as proxies for the relative and absolute reliability, respectively. The number of participants who perceived a sensation during the two sessions at each exposure level was also counted as the perception rate. Mean thermal sensation thresholds were within 0.9°C-1.0°C for the 126-399 mW/cm2 conditions, while that was 0.2°C for the 27 mW/cm2 condition. The ICCs for the threshold at 27 and 126 mW/cm2 were interpreted as poor and fair, respectively, while those at higher exposure levels were moderate to substantial. Apart from a proportional bias in the 191 mW/cm2 condition, there was no fixed bias. All participants perceived a thermal sensation at 399 mW/cm2 in both sessions, and the perception rate gradually decreased with lower exposure levels. Importantly, two-thirds of the participants answered that they felt a thermal sensation in both or one of the sessions at 27 mW/cm2, despite the low-temperature increase. These results suggest that the thermal sensation threshold is around 1.0°C, consistent across exposure levels, while its reliability increases with higher exposure levels. Furthermore, the perception of thermal sensation may be inherently ambiguous owing to the nature of human perception.
Collapse
Affiliation(s)
- Akiko Yuasa
- Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Toyoake, Aichi, Japan
| | - Shintaro Uehara
- Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Toyoake, Aichi, Japan
| | - Kazuki Ushizawa
- Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Toyoake, Aichi, Japan
| | - Sachiko Kodera
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Aichi, Japan
- Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya, Aichi, Japan
| | - Norika Arai
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Aichi, Japan
| | - Akimasa Hirata
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Aichi, Japan
- Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya, Aichi, Japan
| | - Yohei Otaka
- Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Toyoake, Aichi, Japan
| |
Collapse
|
2
|
Ghanim R, Kaushik A, Park J, Abramson A. Communication Protocols Integrating Wearables, Ingestibles, and Implantables for Closed-Loop Therapies. DEVICE 2023; 1:100092. [PMID: 38465200 PMCID: PMC10923538 DOI: 10.1016/j.device.2023.100092] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
Body-conformal sensors and tissue interfacing robotic therapeutics enable the real-time monitoring and treatment of diabetes, wound healing, and other critical conditions. By integrating sensors and drug delivery devices, scientists and engineers have developed closed-loop drug delivery systems with on-demand therapeutic capabilities to provide just-in-time treatments that correspond to chemical, electrical, and physical signals of a target morbidity. To enable closed-loop functionality in vivo, engineers utilize various low-power means of communication that reduce the size of implants by orders of magnitude, increase device lifetime from hours to months, and ensure the secure high-speed transfer of data. In this review, we highlight how communication protocols used to integrate sensors and drug delivery devices, such as radio frequency communication (e.g., Bluetooth, near-field communication), in-body communication, and ultrasound, enable improved treatment outcomes.
Collapse
Affiliation(s)
- Ramy Ghanim
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Anika Kaushik
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Jihoon Park
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Alex Abramson
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
- Division of Digestive Diseases, Emory University School of Medicine, Atlanta, GA 30322, USA
| |
Collapse
|
3
|
O'Brien DJ, Mills D, Farina J, Paranjape M. A Needle-Free Transdermal Patch for Sampling Interstitial Fluid. IEEE Trans Biomed Eng 2023; 70:2573-2580. [PMID: 37028334 DOI: 10.1109/tbme.2023.3253811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
OBJECTIVE Modern diagnostics is pivoting towards less invasive health monitoring in dermal interstitial fluid, rather than blood or urine. However, the skin's outermost layer, the stratum corneum, makes accessing the fluid more difficult without invasive, needle-based technology. Simple, minimally invasive means for surpassing this hurdle are needed. METHODS To address this problem, a flexible, Band-Aid-like patch for sampling interstitial fluid was developed and tested. This patch uses simple resistive heating elements to thermally porate the stratum corneum, allowing the fluid to exude from the deeper skin tissue without applying external pressure. Fluid is then transported to an on-patch reservoir through self-driving hydrophilic microfluidic channels. RESULTS Testing with living, ex-vivo human skin models demonstrated the device's ability to rapidly collect sufficient interstitial fluid for biomarker quantification. Further, finite-element modeling showed that the patch can porate the stratum corneum without raising the skin's temperature to pain-inducing levels in the nerve-laden dermis. CONCLUSION Relying only on simple, commercially scalable fabrication methods, this patch outperforms the collection rate of various microneedle-based patches, painlessly sampling a human bodily fluid without entering the body. SIGNIFICANCE The technology holds potential as a clinical device for an array of biomedical applications, especially with the integration of on-patch testing.
Collapse
|
4
|
Kapetanović A, Poljak D. Machine learning-assisted antenna modelling for realistic assessment of incident power density on non-planar surfaces above 6 GHz. RADIATION PROTECTION DOSIMETRY 2023; 199:826-834. [PMID: 37225223 DOI: 10.1093/rpd/ncad114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
In this paper, the analysis of exposure reference levels is performed for the case of a half-wavelength dipole antenna positioned in the immediate vicinity of non-planar body parts. The incident power density (IPD) spatially averaged over the spherical and cylindrical surface is computed at the 6-90 GHz range, and subsequently placed in the context of the current international guidelines and standards for limiting exposure to electromagnetic (EM) fields which are defined considering planar computational tissue models. As numerical errors are ubiquitous at such high frequencies, the spatial resolution of EM models needs to be increased which in turn results in increased computational complexity and memory requirements. To alleviate this issue, we hybridise machine learning and traditional scientific computing approaches through differentiable programming paradigm. Findings demonstrate a strong positive effect the curvature of non-planar models has on the spatially averaged IPD with up to 15% larger values compared to the corresponding planar model in considered exposure scenarios.
Collapse
Affiliation(s)
- Ante Kapetanović
- Faculty of Electrical Engineering, Mechanical Engineering and Naval Architecture (FESB), University of Split, R. Boškovića 32, 21000 Split, Croatia
| | - Dragan Poljak
- Faculty of Electrical Engineering, Mechanical Engineering and Naval Architecture (FESB), University of Split, R. Boškovića 32, 21000 Split, Croatia
| |
Collapse
|
5
|
Madhvapathy SR, Arafa HM, Patel M, Winograd J, Kong J, Zhu J, Xu S, Rogers JA. Advanced thermal sensing techniques for characterizing the physical properties of skin. APPLIED PHYSICS REVIEWS 2022; 9:041307. [PMID: 36467868 PMCID: PMC9677811 DOI: 10.1063/5.0095157] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Accepted: 09/15/2022] [Indexed: 06/17/2023]
Abstract
Measurements of the thermal properties of the skin can serve as the basis for a noninvasive, quantitative characterization of dermatological health and physiological status. Applications range from the detection of subtle spatiotemporal changes in skin temperature associated with thermoregulatory processes, to the evaluation of depth-dependent compositional properties and hydration levels, to the assessment of various features of microvascular/macrovascular blood flow. Examples of recent advances for performing such measurements include thin, skin-interfaced systems that enable continuous, real-time monitoring of the intrinsic thermal properties of the skin beyond its superficial layers, with a path to reliable, inexpensive instruments that offer potential for widespread use as diagnostic tools in clinical settings or in the home. This paper reviews the foundational aspects of the latest thermal sensing techniques with applicability to the skin, summarizes the various devices that exploit these concepts, and provides an overview of specific areas of application in the context of skin health. A concluding section presents an outlook on the challenges and prospects for research in this field.
Collapse
|
6
|
Lemay E, Gajda GB, McGarr GW, Zhuk M, Paradis J. Analysis of ICNIRP 2020 Basic Restrictions for Localized Radiofrequency Exposure in the Frequency Range above 6 GHz. HEALTH PHYSICS 2022; 123:179-196. [PMID: 35613372 DOI: 10.1097/hp.0000000000001581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
ABSTRACT ICNIRP 2020 guidelines have defined a practical temperature elevation threshold for human health effects, namely the operational adverse health effect threshold that forms the basis of the absorbed power and energy density basic restrictions. These basic restrictions for localized exposures at frequencies above 6 GHz were evaluated by comparing numerically computed temperature rise against the target temperature rise of 2.5 o C, which is the operational adverse health effect threshold divided by the occupational safety factor of 2. The numerical model employs the maximum absorbed power and energy density levels allowed by the occupational basic restriction for both pulsed and continuous wave exposures. These analyses were performed considering 3- and 4-tissue layer models and a variety of beam diameters, frequencies, and exposure durations. The smallest beam diameters were based on a study of theoretically achievable beam widths from half-wave resonant dipoles and show the impact of the averaging area on the computed temperature elevation. The results demonstrated that ICNIRP's assumed occupational safety factors in the frequency range above 6 GHz were not sufficiently maintained for all exposure scenarios and particularly for short pulse exposures at frequencies of 30 GHz or higher with small beam diameters. Worst-case tissue temperature elevations were estimated to be as much as 3.6 times higher than ICNIRP's target temperature increases. Consequently, the authors suggest a small modification in the application of the ICNIRP 2020 localized basic restrictions, thereby limiting the worst-case tissue temperature increases to 1.4 times the target value.
Collapse
Affiliation(s)
- Eric Lemay
- Consumer and Clinical Radiation Protection Bureau, Non-ionizing Radiation Physical Sciences Division, Health Canada, 775 Brookfield Rd., Ottawa, Ontario Canada, K1A 1C1
| | | | | | | | | |
Collapse
|
7
|
Foster KR, Ziskin MC, Balzano Q. Time-temperature Thresholds and Safety Factors for Thermal Hazards from Radiofrequency Energy above 6 GHz. HEALTH PHYSICS 2021; 121:234-247. [PMID: 34261892 PMCID: PMC8300848 DOI: 10.1097/hp.0000000000001447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
ABSTRACT Two major sets of exposure limits for radiofrequency (RF) radiation, those of the International Commission on Nonionizing Radiation Protection (ICNIRP 2020) and the Institute of Electrical and Electronics Engineers (IEEE C95.1-2019), have recently been revised and updated with significant changes in limits above 6 GHz through the millimeter wave (mm-wave) band (30-300 GHz). This review compares available data on thermal damage and pain from exposure to RF energy above 6 GHz with corresponding data from infrared energy and other heat sources and estimates safety factors that are incorporated in the IEEE and ICNIRP RF exposure limits. The benchmarks for damage are the same as used in ICNIRP IR limits: minimal epithelial damage to cornea and first-degree burn (erythema in skin observable within 48 h after exposure). The data suggest that limiting thermal hazard to skin is cutaneous pain for exposure durations less than ≈20 min and thermal damage for longer exposures. Limitations on available data and thermal models are noted. However, data on RF and IR thermal damage and pain thresholds show that exposures far above current ICNIRP and IEEE limits would be required to produce thermally hazardous effects. This review focuses exclusively on thermal hazards from RF exposures above 6 GHz to skin and the cornea, which are the most exposed tissues in the considered frequency range.
Collapse
Affiliation(s)
| | - Marvin C. Ziskin
- Department of Radiology, Temple University Medical School, 3420 N. Broad Street, Philadelphia, PA 19140
| | - Quirino Balzano
- Department of Electrical and Computer Engineering, University of Maryland, College Park, MD 20742
| |
Collapse
|
8
|
Hirata A, Kodera S, Sasaki K, Gomez-Tames J, Laakso I, Wood A, Watanabe S, Foster KR. Human exposure to radiofrequency energy above 6 GHz: review of computational dosimetry studies. Phys Med Biol 2021; 66. [PMID: 33761473 DOI: 10.1088/1361-6560/abf1b7] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 03/24/2021] [Indexed: 11/11/2022]
Abstract
International guidelines/standards for human protection from electromagnetic fields have been revised recently, especially for frequencies above 6 GHz where new wireless communication systems have been deployed. Above this frequency a new physical quantity 'absorbed/epithelial power density' has been adopted as a dose metric. Then, the permissible level of external field strength/power density is derived for practical assessment. In addition, a new physical quantity, fluence or absorbed energy density, is introduced for protection from brief pulses (especially for shorter than 10 s). These limits were explicitly designed to avoid excessive increases in tissue temperature, based on electromagnetic and thermal modeling studies but supported by experimental data where available. This paper reviews the studies on the computational modeling/dosimetry which are related to the revision of the guidelines/standards. The comparisons with experimental data as well as an analytic solution are also been presented. Future research needs and additional comments on the revision will also be mentioned.
Collapse
Affiliation(s)
- Akimasa Hirata
- Dept. of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan.,Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya Japan
| | - Sachiko Kodera
- Dept. of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan
| | - Kensuke Sasaki
- National Institute of Information and Communications Technology, Tokyo, Japan
| | - Jose Gomez-Tames
- Dept. of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan.,Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya Japan
| | - Ilkka Laakso
- Dept. of Electrical Engineering and Automation, Aalto University, Espoo, Finland
| | - Andrew Wood
- Swinburne University of Technology Melbourne, Melbourne, Australia
| | - Soichi Watanabe
- National Institute of Information and Communications Technology, Tokyo, Japan
| | - Kenneth R Foster
- University of Pennsylvania, Philadelphia, PA, United States of America
| |
Collapse
|
9
|
Leszczynski D. Physiological effects of millimeter-waves on skin and skin cells: an overview of the to-date published studies. REVIEWS ON ENVIRONMENTAL HEALTH 2020; 35:493-515. [PMID: 32829319 DOI: 10.1515/reveh-2020-0056] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 05/27/2020] [Indexed: 06/11/2023]
Abstract
The currently ongoing deployment if the fifth generation of the wireless communication technology, the 5G technology, has reignited the health debate around the new kind of radiation that will be used/emitted by the 5G devices and networks - the millimeter-waves. The new aspect of the 5G technology, that is of concern to some of the future users, is that both, antennas and devices will be continuously in a very close proximity of the users' bodies. Skin is the only organ of the human body, besides the eyes, that will be directly exposed to the mm-waves of the 5G technology. However, the whole scientific evidence on the possible effects of millimeter-waves on skin and skin cells, currently consists of only some 99 studies. This clearly indicates that the scientific evidence concerning the possible effects of millimeter-waves on humans is insufficient to devise science-based exposure limits and to develop science-based human health policies. The sufficient research has not been done and, therefore, precautionary measures should be considered for the deployment of the 5G, before the sufficient number of quality research studies will be executed and health risk, or lack of it, scientifically established.
Collapse
|
10
|
Parker JE, Beason CW, Sturgeon SP, Voorhees WB, Johnson SS, Nelson KS, Johnson LR, Whitmore JN. Revisiting 35 and 94 GHZ Millimeter Wave Exposure to the Non-Human Primate Eye. HEALTH PHYSICS 2020; 119:206-215. [PMID: 33290003 DOI: 10.1097/hp.0000000000001216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A previous study reported thermal effects resulting from millimeter wave exposures at 35 and 94 GHz on non-human primates, specifically rhesus monkeys' (Macaca mulatta) corneas, but the data exhibited large variations in the observed temperatures and uncertainties in the millimeter wave dosimetry. By incorporating improvements in models and dosimetry, a non-human primate experiment was conducted involving corneal exposures that agreed well with a three-layer, one-dimensional, thermodynamic model to predict the expected surface temperature rise. The new data indicated that the originally reported safety margins for eye exposures were underestimated by 41 ± 20% over the power densities explored. As a result, the expected minimal visible lesion thresholds should be raised to 10.6 ± 1.5 and 7.1 ± 1.0 J cm at 35 and 94 GHz, respectively, provided that the power density is less than 6 W cm for subjects that are unable to blink. If the blink reflex was active, a power density threshold of 20 W cm could be used to protect the eye, although the eyelid could be burned if the exposure was long enough.
Collapse
Affiliation(s)
- James E Parker
- General Dynamics Information Technology, JBSA Fort Sam Houston, TX 78234
| | - Charles W Beason
- General Dynamics Information Technology, JBSA Fort Sam Houston, TX 78234
| | - Stephen P Sturgeon
- Air Force Research Laboratory, 711th Human Performance Wing, Airman Systems Directorate, Bioeffects Division, Radio Frequency Bioeffects Branch, JBSA Fort Sam Houston, TX 78234
| | - William B Voorhees
- Air Force Research Laboratory, 711th Human Performance Wing, Airman Systems Directorate, Bioeffects Division, Radio Frequency Bioeffects Branch, JBSA Fort Sam Houston, TX 78234
| | - Samuel S Johnson
- Air Force Research Laboratory, 711th Human Performance Wing, Airman Systems Directorate, Bioeffects Division, Radio Frequency Bioeffects Branch, JBSA Fort Sam Houston, TX 78234
| | - Kaitlin S Nelson
- Air Force Research Laboratory, 711th Human Performance Wing, Airman Systems Directorate, Bioeffects Division, Radio Frequency Bioeffects Branch, JBSA Fort Sam Houston, TX 78234
| | - Leland R Johnson
- Air Force Research Laboratory, 711th Human Performance Wing, Airman Systems Directorate, Bioeffects Division, Radio Frequency Bioeffects Branch, JBSA Fort Sam Houston, TX 78234
| | - Jeffrey N Whitmore
- Air Force Research Laboratory, 711th Human Performance Wing, Airman Systems Directorate, Bioeffects Division, Radio Frequency Bioeffects Branch, JBSA Fort Sam Houston, TX 78234
| |
Collapse
|
11
|
Bushberg JT, Chou CK, Foster KR, Kavet R, Maxson DP, Tell RA, Ziskin MC. IEEE Committee on Man and Radiation-COMAR Technical Information Statement: Health and Safety Issues Concerning Exposure of the General Public to Electromagnetic Energy from 5G Wireless Communications Networks. HEALTH PHYSICS 2020; 119:236-246. [PMID: 32576739 PMCID: PMC7337122 DOI: 10.1097/hp.0000000000001301] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Accepted: 04/18/2020] [Indexed: 06/11/2023]
Abstract
This COMAR Technical Information Statement (TIS) addresses health and safety issues concerning exposure of the general public to radiofrequency (RF) fields from 5G wireless communications networks, the expansion of which started on a large scale in 2018 to 2019. 5G technology can transmit much greater amounts of data at much higher speeds for a vastly expanded array of applications compared with preceding 2-4G systems; this is due, in part, to using the greater bandwidth available at much higher frequencies than those used by most existing networks. Although the 5G engineering standard may be deployed for operating networks currently using frequencies extending from 100s to 1,000s of MHz, it can also operate in the 10s of GHz where the wavelengths are 10 mm or less, the so-called millimeter wave (MMW) band. Until now, such fields were found in a limited number of applications (e.g., airport scanners, automotive collision avoidance systems, perimeter surveillance radar), but the rapid expansion of 5G will produce a more ubiquitous presence of MMW in the environment. While some 5G signals will originate from small antennas placed on existing base stations, most will be deployed with some key differences relative to typical transmissions from 2-4G base stations. Because MMW do not penetrate foliage and building materials as well as signals at lower frequencies, the networks will require "densification," the installation of many lower power transmitters (often called "small cells" located mainly on buildings and utility poles) to provide for effective indoor coverage. Also, "beamforming" antennas on some 5G systems will transmit one or more signals directed to individual users as they move about, thus limiting exposures to non-users. In this paper, COMAR notes the following perspectives to address concerns expressed about possible health effects of RF field exposure from 5G technology. First, unlike lower frequency fields, MMW do not penetrate beyond the outer skin layers and thus do not expose inner tissues to MMW. Second, current research indicates that overall levels of exposure to RF are unlikely to be significantly altered by 5G, and exposure will continue to originate mostly from the "uplink" signals from one's own device (as they do now). Third, exposure levels in publicly accessible spaces will remain well below exposure limits established by international guideline and standard setting organizations, including ICNIRP and IEEE. Finally, so long as exposures remain below established guidelines, the research results to date do not support a determination that adverse health effects are associated with RF exposures, including those from 5G systems. While it is acknowledged that the scientific literature on MMW biological effect research is more limited than that for lower frequencies, we also note that it is of mixed quality and stress that future research should use appropriate precautions to enhance validity. The authorship of this paper includes a physician/biologist, epidemiologist, engineers, and physical scientists working voluntarily and collaboratively on a consensus basis.
Collapse
Affiliation(s)
- J T Bushberg
- Committee on Man and Radiation (COMAR), IEEE Engineering in Medicine and Biology Society
| | | | | | | | | | | | | |
Collapse
|
12
|
Abstract
Radiofrequency electromagnetic fields (EMFs) are used to enable a number of modern devices, including mobile telecommunications infrastructure and phones, Wi-Fi, and Bluetooth. As radiofrequency EMFs at sufficiently high power levels can adversely affect health, ICNIRP published Guidelines in 1998 for human exposure to time-varying EMFs up to 300 GHz, which included the radiofrequency EMF spectrum. Since that time, there has been a considerable body of science further addressing the relation between radiofrequency EMFs and adverse health outcomes, as well as significant developments in the technologies that use radiofrequency EMFs. Accordingly, ICNIRP has updated the radiofrequency EMF part of the 1998 Guidelines. This document presents these revised Guidelines, which provide protection for humans from exposure to EMFs from 100 kHz to 300 GHz.
Collapse
|
13
|
Habauzit D, Nugue G, Bourbon F, Martin C, Del Vecchio F, Maunoir-Regimbal S, Poyot T, Valente M, Jaoui R, Crouzier D, Le Dréan Y, Debouzy JC. Evaluation of the Effect of Chronic 94 GHz Exposure on Gene Expression in the Skin of Hairless Rats In Vivo. Radiat Res 2020; 193:351-358. [PMID: 32126188 DOI: 10.1667/rr15470.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Millimeter waves (MMW) are broadband frequencies that have recently been used in several applications in wireless communications, medical devices and nonlethal weapons [i.e., the nonlethal weapon, Active Denial Systems, (ADS) operating at 94-95 GHz, CW]. However, little information is available on their potential effects on humans. These radio-frequencies are absorbed and stopped by the first layer of the skin. In this study, we evaluated the effects of 94 GHz on the gene expression of skin cells. Two rat populations consisting of 17 young animals and 14 adults were subjected to chronic long-term 94 GHz MMW exposure. Each group of animals was divided into exposed and sham subgroups. The two independent exposure experiments were conducted for 5 months with rats exposed 3 h per day for 3 days per week to an incident power density of 10 mW/cm2, which corresponded to twice the ICNIRP limit of occupational exposure for humans. At the end of the experiment, skin explants were collected and RNA was extracted. Then, the modifications to the whole gene expression profile were analyzed with a gene expression microarray. Without modification of the animal's temperature, long-term chronic 94 GHz-MMW exposure did not significantly modify the gene expression of the skin on either the young or adult rats.
Collapse
Affiliation(s)
- Denis Habauzit
- Univ Rennes, Inserm, EHESP, IRSET (Institut de Recherche en Santé, Environnement et Travail) UMR_S 1085, F-35000 Rennes, France
| | - Guillaume Nugue
- Institut de Recherche Biomédicale des Armées (IRBA), F-91223 Brétigny, France
| | - Frédéric Bourbon
- Institut de Recherche Biomédicale des Armées (IRBA), F-91223 Brétigny, France
| | - Catherine Martin
- Univ Rennes, Inserm, EHESP, IRSET (Institut de Recherche en Santé, Environnement et Travail) UMR_S 1085, F-35000 Rennes, France
| | - Flavia Del Vecchio
- Institut de Recherche Biomédicale des Armées (IRBA), F-91223 Brétigny, France
| | | | - Thomas Poyot
- Institut de Recherche Biomédicale des Armées (IRBA), F-91223 Brétigny, France
| | - Marco Valente
- Institut de Recherche Biomédicale des Armées (IRBA), F-91223 Brétigny, France
| | - Rachid Jaoui
- Direction générale de l'armement (DGA/TA), F-31131 Balma, France
| | - David Crouzier
- Institut de Recherche Biomédicale des Armées (IRBA), F-91223 Brétigny, France
| | - Yves Le Dréan
- Univ Rennes, Inserm, EHESP, IRSET (Institut de Recherche en Santé, Environnement et Travail) UMR_S 1085, F-35000 Rennes, France
| | - Jean Claude Debouzy
- Institut de Recherche Biomédicale des Armées (IRBA), F-91223 Brétigny, France
| |
Collapse
|
14
|
Neufeld E, Samaras T, Kuster N. Discussion on Spatial and Time Averaging Restrictions Within the Electromagnetic Exposure Safety Framework in the Frequency Range Above 6 GHz for Pulsed and Localized Exposures. Bioelectromagnetics 2019; 41:164-168. [PMID: 31885092 DOI: 10.1002/bem.22244] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Accepted: 12/17/2019] [Indexed: 11/11/2022]
Abstract
Both the current and newly proposed safety guidelines for local human exposure to millimeter-wave frequencies aim at restricting the maximum local temperature increase in the skin to prevent tissue damage. In this study, we show that the application of the current and proposed limits for pulsed fields can lead to a temperature increase of 10°C for short pulses and frequencies between 6 and 30 GHz. We also show that the proposed averaging area of 4 cm2 , that is greatly reduced compared with the current limits, does not prevent high-temperature increases in the case of narrow beams. A realistic Gaussian beam profile with a 1 mm radius can result in a temperature increase about 10 times higher than the 0.4°C increase the same averaged power density would produce for a plane wave. In the case of pulsed narrow beams, the values for the time and spatial-averaged power density allowed by the proposed new guidelines could result in extreme temperature increases. Bioelectromagnetics. 2020;41:164-168. © 2019 Bioelectromagnetics Society.
Collapse
Affiliation(s)
- Esra Neufeld
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland
| | - Theodoros Samaras
- Department of Physics, Aristotle University of Thessaloniki, Thessaloniki, Greece.,Department of Physics, University of Malta, Msida, Malta
| | - Niels Kuster
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland.,Swiss Federal Institute of Technology (ETH), Zurich, Switzerland
| |
Collapse
|
15
|
Gajda GB, Lemay E, Paradis J. Model of Steady-state Temperature Rise in Multilayer Tissues Due to Narrow-beam Millimeter-wave Radiofrequency Field Exposure. HEALTH PHYSICS 2019; 117:254-266. [PMID: 31125321 DOI: 10.1097/hp.0000000000001036] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The assessment of health effects due to localized exposures from radiofrequency fields is facilitated by characterizing the steady-state, surface temperature rise in tissue. A closed-form analytical model was developed that relates the steady-state, surface temperature rise in multilayer planar tissues as a function of the spatial-peak power density and beam dimensions of an incident millimeter wave. Model data was derived from finite-difference solutions of the Pennes bioheat transfer equation for both normal-incidence plane waves and for narrow, circularly symmetric beams with Gaussian intensity distribution on the surface. Monte Carlo techniques were employed by representing tissue layer thicknesses at different body sites as statistical distributions compiled from human data found in the literature. The finite-difference solutions were validated against analytical solutions of the bioheat equation for the plane wave case and against a narrow-beam solution performed using a commercial multiphysics simulation package. In both cases, agreement was within 1-2%. For a given frequency, the resulting analytical model has four input parameters, two of which are deterministic, describing the level of exposure (i.e., the spatial-peak power density and beam width). The remaining two are stochastic quantities, extracted from the Monte Carlo analyses. The analytical model is composed of relatively simple functions that can be programmed in a spreadsheet. Demonstration of the analytical model is provided in two examples: the calculation of spatial-peak power density vs. beam width that produces a predefined maximum steady-state surface temperature, and the performance evaluation of various proposed spatial-averaging areas for the incident power density.
Collapse
Affiliation(s)
- Gregory B Gajda
- 1Non-ionizing Radiation Physical Sciences Division, Consumer and Clinical Radiation Protection Bureau, Health Canada
| | | | - Jonathan Paradis
- Non-ionizing Radiation Physical Sciences Division, Consumer and Clinical Radiation Protection Bureau, Health Canada
| |
Collapse
|
16
|
Affiliation(s)
- Esra Neufeld
- IT'IS Foundation for Research on Information Technologies in Society, Zurich, Switzerland IT'IS Foundation for Research on Information Technologies in Society, Zurich, Switzerland, Swiss Federal Institute of Technology (ETHZ), Zurich, Switzerland
| | | |
Collapse
|
17
|
Romanenko S, Harvey AR, Hool L, Fan S, Wallace VP. Millimeter Wave Radiation Activates Leech Nociceptors via TRPV1-Like Receptor Sensitization. Biophys J 2019; 116:2331-2345. [PMID: 31103236 DOI: 10.1016/j.bpj.2019.04.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 03/27/2019] [Accepted: 04/15/2019] [Indexed: 12/18/2022] Open
Abstract
There is evidence that millimeter waves (MMWs) can have an impact on cellular function, including neurons. Earlier in vitro studies have shown that exposure levels well below the recommended safe limit of 1 mW/cm2 cause changes in the action potential (AP) firing rate, resting potential, and AP pulse shape of sensory neurons in leech preparations as well as alter neuronal properties in rat cortical brain slices; these effects differ from changes induced by direct heating. In this article, we compare the responses of thermosensitive primary nociceptors of the medicinal leech under thermal heating and MMW irradiation (80-170 mW/cm2 at 60 GHz). The results show that MMW exposure causes an almost twofold decrease in the threshold for activation of the AP compared with thermal heating (3.9 ± 0.4 vs. 8.3 ± 0.4 mV, respectively). Our analysis suggests that MMWs-mediated threshold alterations are not caused by the enhancement of voltage-gated sodium and potassium conductance. We propose that the reduction in AP threshold can be attributed to the sensitization of the transient receptor potential vanilloid 1-like receptor in the leech nociceptor. In silico modeling supported our experimental findings. Our results provide evidence that MMW exposure stimulates specific receptor responses that differ from direct thermal heating, fostering the need for additional studies.
Collapse
Affiliation(s)
- Sergii Romanenko
- Department of Physics, The University of Western Australia, Perth, Western Australia, Australia.
| | - Alan R Harvey
- School of Human Sciences, The University of Western Australia, Perth, Western Australia, Australia; Perron Institute for Neurological and Translational Science, Perth, Western Australia, Australia
| | - Livia Hool
- School of Human Sciences, The University of Western Australia, Perth, Western Australia, Australia; Victor Chang Cardiac Research Institute, Sydney, New South Wales, Australia
| | - Shuting Fan
- Department of Physics, The University of Western Australia, Perth, Western Australia, Australia; College of Electronic Science and Technology, Shenzhen University, Shenzhen, China
| | - Vincent P Wallace
- Department of Physics, The University of Western Australia, Perth, Western Australia, Australia
| |
Collapse
|
18
|
The Effect of a Single 30-Min Long Term Evolution Mobile Phone-Like Exposure on Thermal Pain Threshold of Young Healthy Volunteers. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2018; 15:ijerph15091849. [PMID: 30150567 PMCID: PMC6165439 DOI: 10.3390/ijerph15091849] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 08/22/2018] [Accepted: 08/23/2018] [Indexed: 11/26/2022]
Abstract
Although the majority of mobile phone (MP) users do not attribute adverse effects on health or well-being to MP-emitted radiofrequency (RF) electromagnetic fields (EMFs), the exponential increase in the number of RF devices necessitates continuing research aimed at the objective investigation of such concerns. Here we investigated the effects of acute exposure from Long Term Evolution (LTE) MP EMFs on thermal pain threshold in healthy young adults. We use a protocol that was validated in a previous study in a capsaicin-induced hyperalgesia model and was also successfully used to show that exposure from an RF source mimicking a Universal Mobile Telecommunications System (UMTS) MP led to mildly stronger desensitization to repeated noxious thermal stimulation relative to the sham condition. Using the same experimental design, we did not find any effects of LTE exposure on thermal pain threshold. The present results, contrary to previous evidence obtained with the UMTS modulation, are likely to originate from placebo/nocebo effects and are unrelated to the brief acute LTE EMF exposure itself. The fact that this is dissimilar to our previous results on UMTS exposure implies that RF modulations might differentially affect pain perception and points to the necessity of further research on the topic.
Collapse
|
19
|
Foster KR, Ziskin MC, Balzano Q, Bit-Babik G. Modeling Tissue Heating From Exposure to Radiofrequency Energy and Relevance of Tissue Heating to Exposure Limits: Heating Factor. HEALTH PHYSICS 2018; 115:295-307. [PMID: 29957690 DOI: 10.1097/hp.0000000000000854] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This review/commentary addresses recent thermal and electromagnetic modeling studies that use image-based anthropomorphic human models to establish the local absorption of radiofrequency energy and the resulting increase in temperature in the body. The frequency range of present interest is from 100 MHz through the transition frequency (where the basic restrictions in exposure guidelines change from specific absorption rate to incident power density, which occurs at 3-10 GHz depending on the guideline). Several detailed thermal modeling studies are reviewed to compare a recently introduced dosimetric quantity, the heating factor, across different exposure conditions as related to the peak temperature rise in tissue that would be permitted by limits for local body exposure. The present review suggests that the heating factor is a robust quantity that is useful for normalizing exposures across different simulation models. Limitations include lack of information about the location in the body where peak absorption and peak temperature increases occur in each exposure scenario, which are needed for careful assessment of potential hazards. To the limited extent that comparisons are possible, the thermal model (which is based on Pennes' bioheat equation) agrees reasonably well with experimental data, notwithstanding the lack of theoretical rigor of the model and uncertainties in the model parameters. In particular, the blood flow parameter is both variable with physiological condition and largely determines the steady state temperature rise. We suggest an approach to define exposure limits above and below the transition frequency (the frequency at which the basic restriction changes from specific absorption rate to incident power density) to provide consistent levels of protection against thermal hazards. More research is needed to better validate the model and to improve thermal dosimetry in general. While modeling studies have considered the effects of variation in thickness of tissue layers, the effects of normal physiological variation in tissue blood flow have been relatively unexplored.
Collapse
Affiliation(s)
- Kenneth R Foster
- Department of Bioengineering, University of Pennsylvania, 240 Skirkanich Hall, 210 S. 33rd Street, Philadelphia, PA 19104
| | - Marvin C Ziskin
- Temple University Medical School, 3420 N. Broad Street, Philadelphia, PA 19140
| | - Quirino Balzano
- Department of Electrical and Computer Engineering, University of Maryland, College Park MD 20742
| | - Giorgi Bit-Babik
- Chief Technology Office, Motorola Solutions, Inc., Fort Lauderdale, FL 33322
| |
Collapse
|
20
|
Ziskin MC, Alekseev SI, Foster KR, Balzano Q. Tissue models for RF exposure evaluation at frequencies above 6 GHz. Bioelectromagnetics 2018; 39:173-189. [DOI: 10.1002/bem.22110] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Accepted: 12/13/2017] [Indexed: 11/08/2022]
Affiliation(s)
- Marvin C. Ziskin
- Department of RadiologyTemple University School of MedicinePhiladelphia, Pennsylvania
| | | | - Kenneth R. Foster
- Department of BioengineeringUniversity of PennsylvaniaPhiladelphia, Pennsylvania
| | - Quirino Balzano
- Department of Electrical EngineeringUniversity of MarylandCollege Park, Maryland
| |
Collapse
|
21
|
Laakso I, Morimoto R, Heinonen J, Jokela K, Hirata A. Human exposure to pulsed fields in the frequency range from 6 to 100 GHz. Phys Med Biol 2017; 62:6980-6992. [PMID: 28791963 DOI: 10.1088/1361-6560/aa81fe] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Restrictions on human exposure to electromagnetic waves at frequencies higher than 3-10 GHz are defined in terms of the incident power density to prevent excessive temperature rise in superficial tissue. However, international standards and guidelines differ in their definitions of how the power density is interpreted for brief exposures. This study investigated how the temperature rise was affected by exposure duration at frequencies higher than 6 GHz. Far-field exposure of the human face to pulses shorter than 10 s at frequencies from 6 to 100 GHz was modelled using the finite-difference time-domain method. The bioheat transfer equation was used for thermal modelling. We investigated the effects of frequency, polarization, exposure duration, and depth below the skin surface on the temperature rise. The results indicated limitations in the current human exposure guidelines and showed that radiant exposure, i.e. energy absorption per unit area, can be used to limit temperature rise for pulsed exposure. The data are useful for the development of human exposure guidelines at frequencies higher than 6 GHz.
Collapse
Affiliation(s)
- Ilkka Laakso
- Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
| | | | | | | | | |
Collapse
|
22
|
Foster KR, Ziskin MC, Balzano Q. Thermal Modeling for the Next Generation of Radiofrequency Exposure Limits: Commentary. HEALTH PHYSICS 2017; 113:41-53. [PMID: 28542010 DOI: 10.1097/hp.0000000000000671] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This commentary evaluates two sets of guidelines for human exposure to radiofrequency (RF) energy, focusing on the frequency range above the "transition" frequency at 3-10 GHz where the guidelines change their basic restrictions from specific absorption rate to incident power density, through the end of the RF band at 300 GHz. The analysis is based on a simple thermal model based on Pennes' bioheat equation (BHTE) (Pennes 1948) assuming purely surface heating; an Appendix provides more details about the model and its range of applicability. This analysis suggests that present limits are highly conservative relative to their stated goals of limiting temperature increase in tissue. As applied to transmitting devices used against the body, they are much more conservative than product safety standards for touch temperature for personal electronics equipment that are used in contact with the body. Provisions in the current guidelines for "averaging time" and "averaging area" are not consistent with scaling characteristics of the bioheat equation and should be refined. The authors suggest the need for additional limits on fluence for protection against brief, high intensity pulses at millimeter wave frequencies. This commentary considers only thermal hazards, which form the basis of the current guidelines, and excludes considerations of reported "non-thermal" effects of exposure that would have to be evaluated in the process of updating the guidelines.
Collapse
Affiliation(s)
- Kenneth R Foster
- *Department of Bioengineering University of Pennsylvania; †Temple University Medical School, 3420 N. Broad Street, Philadelphia, PA; ‡Department of Electrical and Computer Engineering, University of Maryland, College Park, MD
| | | | | |
Collapse
|
23
|
Foster KR, Ziskin MC, Balzano Q. Thermal Response of Human Skin to Microwave Energy: A Critical Review. HEALTH PHYSICS 2016; 111:528-541. [PMID: 27798477 DOI: 10.1097/hp.0000000000000571] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
This is a review/modeling study of heating of tissue by microwave energy in the frequency range from 3 GHz through the millimeter frequency range (30-300 GHz). The literature was reviewed to identify studies that reported RF-induced increases in skin temperature. A simple thermal model, based on a simplified form of Pennes' bioheat equation (BHTE), was developed, using parameter values taken from the literature with no further adjustment. The predictions of the model were in excellent agreement with available data. A parametric analysis of the model shows that there are two heating regimes with different dominant mechanisms of heat transfer. For small irradiated areas (less than about 0.5-1 cm in radius) the temperature increase at the skin surface is chiefly limited by conduction of heat into deeper tissue layers, while for larger irradiated areas, the steady-state temperature increase is limited by convective cooling by blood perfusion. The results support the use of this simple thermal model to aid in the development and evaluation of RF safety limits at frequencies above 3 GHz and for millimeter waves, particularly when the irradiated area of skin is small. However, very limited thermal response data are available, particularly for exposures lasting more than a few minutes to areas of skin larger than 1-2 cm in diameter. The paper concludes with comments about possible uses and limitations of thermal modeling for setting exposure limits in the considered frequency range.
Collapse
Affiliation(s)
- Kenneth R Foster
- *Department of Bioengineering University of Pennsylvania, Philadelphia, PA; †Temple University Medical School, Philadelphia, PA; ‡Department of Electrical and Computer Engineering, University of Maryland, College Park, MD
| | | | | |
Collapse
|
24
|
Portable Wideband Microwave Imaging System for Intracranial Hemorrhage Detection Using Improved Back-projection Algorithm with Model of Effective Head Permittivity. Sci Rep 2016; 6:20459. [PMID: 26842761 PMCID: PMC4740863 DOI: 10.1038/srep20459] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 11/25/2015] [Indexed: 11/17/2022] Open
Abstract
Intracranial hemorrhage is a medical emergency that requires rapid detection and medication to restrict any brain damage to minimal. Here, an effective wideband microwave head imaging system for on-the-spot detection of intracranial hemorrhage is presented. The operation of the system relies on the dielectric contrast between healthy brain tissues and a hemorrhage that causes a strong microwave scattering. The system uses a compact sensing antenna, which has an ultra-wideband operation with directional radiation, and a portable, compact microwave transceiver for signal transmission and data acquisition. The collected data is processed to create a clear image of the brain using an improved back projection algorithm, which is based on a novel effective head permittivity model. The system is verified in realistic simulation and experimental environments using anatomically and electrically realistic human head phantoms. Quantitative and qualitative comparisons between the images from the proposed and existing algorithms demonstrate significant improvements in detection and localization accuracy. The radiation and thermal safety of the system are examined and verified. Initial human tests are conducted on healthy subjects with different head sizes. The reconstructed images are statistically analyzed and absence of false positive results indicate the efficacy of the proposed system in future preclinical trials.
Collapse
|
25
|
Zhadobov M, Alekseev SI, Le Dréan Y, Sauleau R, Fesenko EE. Millimeter waves as a source of selective heating of skin. Bioelectromagnetics 2015; 36:464-75. [DOI: 10.1002/bem.21929] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2014] [Accepted: 06/09/2015] [Indexed: 11/11/2022]
Affiliation(s)
- Maxim Zhadobov
- Institute of Electronics and Telecommunications of Rennes (IETR); UMR CNRS 6164; University of Rennes 1; Rennes France
| | - Stanislav I. Alekseev
- Institute of Cell Biophysics of Russian Academy of Sciences; Pushchino Moscow Region Russia
| | - Yves Le Dréan
- Institute for Research on Environmental and Occupational Health (IRSET); University of Rennes 1; Rennes France
| | - Ronan Sauleau
- Institute of Electronics and Telecommunications of Rennes (IETR); UMR CNRS 6164; University of Rennes 1; Rennes France
| | - Evgeny E. Fesenko
- Institute of Cell Biophysics of Russian Academy of Sciences; Pushchino Moscow Region Russia
| |
Collapse
|
26
|
Wu T, Rappaport TS, Collins CM. Safe for Generations to Come. IEEE MICROWAVE MAGAZINE 2015; 16:65-84. [PMID: 26539066 PMCID: PMC4629874 DOI: 10.1109/mmm.2014.2377587] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Affiliation(s)
- Ting Wu
- New York University (NYU) WIRELESS, the NYU Polytechnic School of Engineering, Brooklyn, New York, United States. ( )
| | - Theodore S Rappaport
- NYU WIRELESS, the NYU Polytechnic School of Engineering, Brooklyn, New York, United States, and the NYU Department of Radiology, New York, United States. ( )
| | | |
Collapse
|
27
|
Romanenko S, Siegel PH, Wagenaar DA, Pikov V. Effects of millimeter wave irradiation and equivalent thermal heating on the activity of individual neurons in the leech ganglion. J Neurophysiol 2014; 112:2423-31. [PMID: 25122711 PMCID: PMC4233276 DOI: 10.1152/jn.00357.2014] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Many of today's radiofrequency-emitting devices in telecommunication, telemedicine, transportation safety, and security/military applications use the millimeter wave (MMW) band (30–300 GHz). To evaluate the biological safety and possible applications of this radiofrequency band for neuroscience and neurology, we have investigated the physiological effects of low-intensity 60-GHz electromagnetic irradiation on individual neurons in the leech midbody ganglia. We applied incident power densities of 1, 2, and 4 mW/cm2 to the whole ganglion for a period of 1 min while recording the action potential with a standard sharp electrode electrophysiology setup. For comparison, the recognized U.S. safe exposure limit is 1 mW/cm2 for 6 min. During the exposure to MMWs and gradual bath heating at a rate of 0.04°C/s (2.4°C/min), the ganglionic neurons exhibited similar dose-dependent hyperpolarization of the plasma membrane and decrease in the action potential amplitude. However, narrowing of the action potential half-width during MMW irradiation at 4 mW/cm2 was 5 times more pronounced compared with that during equivalent bath heating of 0.6°C. Even more dramatic difference in the effects of MMW irradiation and bath heating was noted in the firing rate, which was suppressed at all applied MMW power densities and increased in a dose-dependent manner during gradual bath heating. The mechanism of enhanced narrowing of action potentials and suppressed firing by MMW irradiation, compared with that by gradual bath heating, is hypothesized to involve specific coupling of MMW energy with the neuronal plasma membrane.
Collapse
Affiliation(s)
- Sergii Romanenko
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California; Neural Engineering Program, Huntington Medical Research Institutes, Pasadena, California; and
| | - Peter H Siegel
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California
| | - Daniel A Wagenaar
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, California; Department of Biological Sciences, University of Cincinnati, Cincinnati, Ohio
| | - Victor Pikov
- Neural Engineering Program, Huntington Medical Research Institutes, Pasadena, California; and
| |
Collapse
|
28
|
Karampatzakis A, Samaras T. Numerical modeling of heat and mass transfer in the human eye under millimeter wave exposure. Bioelectromagnetics 2013; 34:291-9. [DOI: 10.1002/bem.21774] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Accepted: 11/28/2012] [Indexed: 11/10/2022]
|
29
|
Samsonov A, Popov SV. The effect of a 94 GHz electromagnetic field on neuronal microtubules. Bioelectromagnetics 2012; 34:133-44. [PMID: 23080284 DOI: 10.1002/bem.21760] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2011] [Accepted: 09/15/2012] [Indexed: 11/05/2022]
Abstract
Hardware that generates electromagnetic waves with wavelengths from 1 to 10 mm (millimeter waves, "MMW") is being used in a variety of applications, including high-speed data communication and medical devices. This raises both practical and fundamental issues concerning the interaction of MMW electromagnetic fields (EMF) with biological tissues. A 94 GHz EMF is of particular interest because a number of applications, such as active denial systems, rely on this specific frequency. Most of the energy associated with MMW radiation is absorbed in the skin and, for a 94 GHz field, the power penetration depth is shallow (≈0.4 mm). At sufficiently high energies, skin heating is expected to activate thermal pain receptors, leading to the perception of pain. In addition to this "thermal" mechanism of action, a number of "non-thermal" effects of MMW fields have been previously reported. Here, we investigated the influence of a 94 GHz EMF on the assembly/disassembly of neuronal microtubules in Xenopus spinal cord neurons. We reasoned that since microtubule array is regulated by a large number of intracellular signaling cascades, it may serve as an exquisitely sensitive reporter for the biochemical status of neuronal cytoplasm. We found that exposure to 94 GHz radiation increases the rate of microtubule assembly and that this effect can be entirely accounted for by the rapid EMF-elicited temperature jump. Our data are consistent with the notion that the cellular effects of a 94 GHz EMF are mediated entirely by cell heating.
Collapse
Affiliation(s)
- Andrey Samsonov
- Department of Physiology and Biophysics, University of Illinois at Chicago, Chicago, IL 60612, USA
| | | |
Collapse
|
30
|
Alekseev SI, Ziskin MC, Fesenko EE. Frequency dependence of heating of human skin exposed to millimeter waves. Biophysics (Nagoya-shi) 2012. [DOI: 10.1134/s0006350912010046] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
31
|
Zhadobov M, Sauleau R, Augustine R, Le Quément C, Le Dréan Y, Thouroude D. Near-field dosimetry for in vitro exposure of human cells at 60 GHz. Bioelectromagnetics 2011; 33:55-64. [PMID: 21713963 DOI: 10.1002/bem.20685] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2011] [Revised: 05/30/2011] [Indexed: 12/11/2022]
Abstract
Due to the expected mass deployment of millimeter-wave wireless technologies, thresholds of potential millimeter-wave-induced biological and health effects should be carefully assessed. The main purpose of this study is to propose, optimize, and characterize a near-field exposure configuration allowing illumination of cells in vitro at 60 GHz with power densities up to several tens of mW/cm(2) . Positioning of a tissue culture plate containing cells has been optimized in the near-field of a standard horn antenna operating at 60 GHz. The optimal position corresponds to the maximal mean-to-peak specific absorption rate (SAR) ratio over the cell monolayer, allowing the achievement of power densities up to 50 mW/cm(2) at least. Three complementary parameters have been determined and analyzed for the exposed cells, namely the power density, SAR, and temperature dynamics. The incident power density and SAR have been computed using the finite-difference time-domain (FDTD) method. The temperature dynamics at different locations inside the culture medium are measured and analyzed for various power densities. Local SAR, determined based on the initial rate of temperature rise, is in a good agreement with the computed SAR (maximal difference of 5%). For the optimized exposure setup configuration, 73% of cells are located within the ±3 dB region with respect to the average SAR. It is shown that under the considered exposure conditions, the maximal power density, local SAR, and temperature increments equal 57 mW/cm(2) , 1.4 kW/kg, and 6 °C, respectively, for the radiated power of 425 mW.
Collapse
Affiliation(s)
- Maxim Zhadobov
- Institute of Electronics and Telecommunications of Rennes (IETR), University of Rennes, France.
| | | | | | | | | | | |
Collapse
|
32
|
Papaioannou A, Samaras T. Numerical model of heat transfer in the rabbit eye exposed to 60-GHz millimeter wave radiation. IEEE Trans Biomed Eng 2011; 58:2582-8. [PMID: 21672669 DOI: 10.1109/tbme.2011.2159502] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A numerical model of the anterior chamber of the rabbit eye is presented. The model takes into account both the fluid dynamics of the aqueous humor and the realistic boundary conditions at the interface of the cornea with the environment. The model is used to determine the temperature distribution and velocity field under 60-GHz millimeter wave radiation. The maximum predicted temperature (45.8 (°) C for an incident power density of 475 mW/cm(2)) is in good agreement with experimental results. Moreover, the model shows that there is a value for the incident power density (about 100 mW/cm(2)) for which the direction of aqueous humor flow due to buoyancy is inverted, because of the inversion of the temperature gradient in the anterior chamber of the eye. This phenomenon has already been reported from experimental observations and can be numerically studied, if aqueous humor fluid dynamics are taken into account in the heat-transfer model.
Collapse
Affiliation(s)
- Anastasios Papaioannou
- Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
| | | |
Collapse
|
33
|
Shafirstein G, Moros EG. Modelling millimetre wave propagation and absorption in a high resolution skin model: the effect of sweat glands. Phys Med Biol 2011; 56:1329-39. [DOI: 10.1088/0031-9155/56/5/007] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
34
|
Foster KR, Zhang H, Osepchuk JM. Thermal response of tissues to millimeter waves: implications for setting exposure guidelines. HEALTH PHYSICS 2010; 99:806-810. [PMID: 21068599 DOI: 10.1097/hp.0b013e3181db29e6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
This Note discusses the implications of a simple model for the thermal response of tissue subject to irradiation with millimeter waves (30-300 GHz) for setting limits for safe exposure to this energy. The estimated thresholds for thermal pain and thermal injury from long-term (minutes) and short-term (seconds) exposures are compared with two major exposure guidelines, IEEE C95.1-2005 and ICNIRP limits. An Appendix describes the rationale for setting the "averaging times" in IEEE C95.1-2005.
Collapse
Affiliation(s)
- Kenneth R Foster
- Department of Bioengineering, University of Pennsylvania, 210 S. 33rd Street, Philadelphia, PA 19104, USA.
| | | | | |
Collapse
|
35
|
Moghimi HR, Alinaghi A, Erfan M. Investigating the potential of non-thermal microwave as a novel skin penetration enhancement method. Int J Pharm 2010; 401:47-50. [PMID: 20854885 DOI: 10.1016/j.ijpharm.2010.09.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2010] [Accepted: 09/14/2010] [Indexed: 12/01/2022]
Abstract
Microwaves (MW), a part of the electromagnetic spectrum at 0.3-300GHz, affect human body in different ways through its thermal and athermal effects, including fluidization of cell membranes and liquid crystalline systems. Due to presence of such structures in skin barrier, it was decided here to investigate the potential of athermal MW as skin penetration enhancer. In this investigation, nitrofurazone was chosen as the model penetrant and its permeation through rat skin was studied in vitro at 45 and 90min exposure intervals using MW intensities of 3, 15, 30, 60, 120W at 2450MHz. Results revealed that at 30°C and 45min exposure, 3W MW does not affect permeation of nitrofurazone (P=0.148), while higher intensities increased its flux significantly (P<0.05) in a intensity-dependent manner up to 2.7 times. When the duration of exposure increased to 90min, the enhancement ratio also increased to reach a maximum of 3.3. Applying 60W MW at 25, 30, 37 and 42°C resulted in a parabolic relationship between temperature and enhancement ratio. The present results reveal that microwave can act as a skin penetration enhancement method and that its effect depends on applied intensities, exposure time and temperature.
Collapse
Affiliation(s)
- Hamid R Moghimi
- School of Pharmacy, Shaheed Beheshti Medical University, Valiasr Ave., Niayesh Junction, P.O. Box 14155-6153, Tehran, Iran.
| | | | | |
Collapse
|
36
|
Pickard WF, Moros EG, Shafirstein G. Electromagnetic and thermal evaluation of an applicator specialized to permit high-resolution non-perturbing optical evaluation of cells being irradiated in the W-band. Bioelectromagnetics 2009; 31:140-9. [PMID: 19731242 DOI: 10.1002/bem.20539] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
To permit epi-illuminated, high-resolution optical microscopy of cells in monolayer culture during unperturbed W-band (75-110 GHz) irradiation, a new class of applicator has been developed based upon WR10 rectangular waveguide components: the cells are normally plated onto the underside of a coverslip which is then placed against the under side of a waveguide flange and receives a roughly circular exposure pattern, with the +/-1 dB central spot roughly 1 mm in diameter. Constructed and tested with 94 GHz millimeter waves, water-immersion optics, and free-convection cooling, the applicator works robustly and permits SARs at the cell layer as high as 4500 W/kg before the steady-state temperature rise at the cell layer exceeds 0.5 K.
Collapse
Affiliation(s)
- William F Pickard
- Department of Electrical and Systems Engineering, Washington University, Saint Louis, MO 63130, USA.
| | | | | |
Collapse
|
37
|
Millenbaugh NJ, Roth C, Sypniewska R, Chan V, Eggers JS, Kiel JL, Blystone RV, Mason PA. Gene Expression Changes in the Skin of Rats Induced by Prolonged 35 GHz Millimeter-Wave Exposure. Radiat Res 2008; 169:288-300. [DOI: 10.1667/rr1121.1] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2007] [Accepted: 11/08/2007] [Indexed: 11/03/2022]
|
38
|
Shih TC, Yuan P, Lin WL, Kou HS. Analytical analysis of the Pennes bioheat transfer equation with sinusoidal heat flux condition on skin surface. Med Eng Phys 2007; 29:946-53. [PMID: 17137825 DOI: 10.1016/j.medengphy.2006.10.008] [Citation(s) in RCA: 136] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2006] [Revised: 10/13/2006] [Accepted: 10/16/2006] [Indexed: 11/30/2022]
Abstract
This study focuses on the effect of the temperature response of a semi-infinite biological tissue due to a sinusoidal heat flux at the skin. The Pennes bioheat transfer equation such as rho(t)c(t)( partial differentialT/ partial differentialt)+W(b)c(b)(T-T(a))=k partial differential(2)T/ partial differentialx(2) with the oscillatory heat flux boundary condition such as q(0,t)=q(0)e(iomegat) was investigated. By using the Laplace transform, the analytical solution of the Pennes bioheat transfer equation with surface sinusoidal heating condition is found. This analytical expression is suitable for describing the transient temperature response of tissue for the whole time domain from the starting periodic oscillation to the final steady periodic oscillation. The results show that the temperature oscillation due to the sinusoidal heating on the skin surface is unstable in the initial period. Further, it is unavailable to predict the blood perfusion rate via the phase shifting between the surface heat flux and the surface temperature. Moreover, the lower frequency of sinusoidal heat flux on the skin surface induces a more sensitive phase shift response to the blood perfusion rate change, but extends the beginning time of sampling because of the avoidance of the unavailable first cyclic oscillation.
Collapse
Affiliation(s)
- Tzu-Ching Shih
- Department of Medical Radiology Technology, China Medical University, Taiwan
| | | | | | | |
Collapse
|
39
|
Debouzy JC, Crouzier D, Dabouis V, Malabiau R, Bachelet C, Perrin A. Effets biologiques des rayonnements millimétriques (94 GHz). Quelles conséquences à long terme ? ACTA ACUST UNITED AC 2007; 55:246-55. [PMID: 16631319 DOI: 10.1016/j.patbio.2006.02.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2006] [Accepted: 02/24/2006] [Indexed: 11/23/2022]
Abstract
Active Denial Systems (ADS) is a millimetric wave radiation emitting technology now included in the non lethal weapon arsenal. Such devices emit electromagnetic, thus agitating water in the skin and causing feeling of heat enough that target individual retreats from the beam. They can be used at up to 1 km from the target. We have reviewed the literature on the interactions of millimetric waves (MMW) with biological systems. An opposition appears between the observations performed in the Former Soviet Union and Russia showing potential interaction sometimes deleterious while generally of good influence and used in therapy. By way of contrast, most of the other studies, performed in USA, address local acute effects, exclusively located on the skin and eyes of the target, and considered as completely reversible.
Collapse
Affiliation(s)
- J-C Debouzy
- Unité de biophysique cellulaire et moléculaire, centre de recherche du service de santé des armées (CRSSA/BCM), 24, avenue des maquis-du-Grésivaudan, BP 87, 38702 La Tronche cedex, France.
| | | | | | | | | | | |
Collapse
|
40
|
Foster KR, Glaser R. Thermal mechanisms of interaction of radiofrequency energy with biological systems with relevance to exposure guidelines. HEALTH PHYSICS 2007; 92:609-20. [PMID: 17495663 DOI: 10.1097/01.hp.0000262572.64418.38] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
This article reviews thermal mechanisms of interaction between radiofrequency (RF) fields and biological systems, focusing on theoretical frameworks that are of potential use in setting guidelines for human exposure to RF energy. Several classes of thermal mechanisms are reviewed that depend on the temperature increase or rate of temperature increase and the relevant dosimetric considerations associated with these mechanisms. In addition, attention is drawn to possible molecular and physiological reactions that could be induced by temperature elevations below 0.1 degrees, which are normal physiological responses to heat, and to the so-called microwave auditory effect, which is a physiologically trivial effect resulting from thermally-induced acoustic stimuli. It is suggested that some reported "nonthermal" effects of RF energy may be thermal in nature; also that subtle thermal effects from RF energy exist but have no consequence to health or safety. It is proposed that future revisions of exposure guidelines make more explicit use of thermal models and empirical data on thermal effects in quantifying potential hazards of RF fields.
Collapse
Affiliation(s)
- Kenneth R Foster
- University of Pennsylvania, Department of Bioengineering, Philadelphia, PA 19104, USA.
| | | |
Collapse
|
41
|
|
42
|
Pickard WF, Moros EG, Cha BA, Novak P. Electromagnetic and thermal characterization of an UHF-applicator for concurrent irradiation and high resolution non-perturbing optical microscopy of cells. Bioelectromagnetics 2006; 27:593-601. [PMID: 16736489 DOI: 10.1002/bem.20250] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
To permit trans-illuminated, high-resolution optical microscopy during unperturbed ultrahigh frequency (UHF) irradiation, a novel new class of applicator has been designed based upon a shielded-pair transmission line. As constructed and tested with water-immersion optics and air cooling, the applicator works most robustly over 700-1100 MHz and permits SARs at the cell layer as high as 50 W/kg before the steady state temperature rise at the cell-layer exceeds 0.5 K.
Collapse
Affiliation(s)
- William F Pickard
- Department of Electrical and Systems Engineering, Washington University, Saint Louis, Missouri 63130, USA.
| | | | | | | |
Collapse
|
43
|
Millenbaugh NJ, Kiel JL, Ryan KL, Blystone RV, Kalns JE, Brott BJ, Cerna CZ, Lawrence WS, Soza LL, Mason PA. COMPARISON OF BLOOD PRESSURE AND THERMAL RESPONSES IN RATS EXPOSED TO MILLIMETER WAVE ENERGY OR ENVIRONMENTAL HEAT. Shock 2006; 25:625-32. [PMID: 16721271 DOI: 10.1097/01.shk.0000209550.11087.fd] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Electromagnetic fields at millimeter wave lengths are being developed for commercial and military use at power levels that can cause temperature increases in the skin. Previous work suggests that sustained exposure to millimeter waves causes greater heating of skin, leading to faster induction of circulatory failure than exposure to environmental heat (EH). We tested this hypothesis in three separate experiments by comparing temperature changes in skin, subcutis, and colon, and the time to reach circulatory collapse (mean arterial blood pressure, 20 mmHg) in male Sprague-Dawley rats exposed to the following conditions that produced similar rates of body core heating within each experiment: (1) EH at 42 degrees C, 35 GHz at 75 mW/cm, or 94 GHz at 75 mW/cm under ketamine and xylazine anesthesia; (2) EH at 43 degrees C, 35 GHz at 90 mW/cm, or 94 GHz at 90 mW/cm under ketamine and xylazine anesthesia; and (3) EH at 42 degrees C, 35 GHz at 90 mW/cm, or 94 GHz at 75 mW/cm under isoflurane anesthesia. In all three experiments, the rate and amount of temperature increase at the subcutis and skin surface differed significantly in the rank order of 94 GHz more than 35 GHz more than EH. The time to reach circulatory collapse was significantly less only for rats exposed to 94 GHz at 90 mW/cm, the group with the greatest rate of skin and subcutis heating of all groups in this study, compared with both the 35 GHz at 90 mW/cm and the EH at 43 degrees C groups. These data indicate that body core heating is the major determinant of induction of hemodynamic collapse, and the influence of heating of the skin and subcutis becomes significant only when a certain threshold rate of heating of these tissues is exceeded.
Collapse
|
44
|
Alekseev SI, Radzievsky AA, Szabo I, Ziskin MC. Local heating of human skin by millimeter waves: Effect of blood flow. Bioelectromagnetics 2005; 26:489-501. [PMID: 15931684 DOI: 10.1002/bem.20118] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We investigated the influence of blood perfusion on local heating of the forearm and middle finger skin following 42.25 GHz exposure with an open ended waveguide (WG) and with a YAV mm wave therapeutic device. Both sources had bell-shaped distributions of the incident power density (IPD) with peak intensities of 208 and 55 mW/cm(2), respectively. Blood perfusion was changed in two ways: by blood flow occlusion and by externally applied vasodilator (nonivamide/nicoboxil) cream to the skin. For thermal modeling, we used the bioheat transfer equation (BHTE) and the hybrid bioheat equation (HBHE) which combines the BHTE and the scalar effective thermal conductivity equation (ETCE). Under normal conditions with the 208 mW/cm(2) exposure, the cutaneous temperature elevation (DeltaT) in the finger (2.5 +/- 0.3 degrees C) having higher blood flow was notably smaller than the cutaneous DeltaT in the forearm (4.7 +/- 0.4 degrees C). However, heating of the forearm and finger skin with blood flow occluded was the same, indicating that the thermal conductivity of tissue in the absence of blood flow at both locations was also the same. The BHTE accurately predicted local hyperthermia in the forearm only at low blood flow. The HBHE made accurate predictions at both low and high perfusion rates. The relationship between blood flow and the effective thermal conductivity (k(eff)) was found to be linear. The heat dissipating effect of higher perfusion was mostly due to an apparent increase in k(eff). It was shown that mm wave exposure could result in steady state heating of tissue layers located much deeper than the penetration depth (0.56 mm). The surface DeltaT and heat penetration into tissue increased with enlarging the irradiating beam area and with increasing exposure duration. Thus, mm waves at sufficient intensities could thermally affect thermo-sensitive structures located in the skin and underlying tissue.
Collapse
Affiliation(s)
- S I Alekseev
- Center for Biomedical Physics, Temple University Medical School, 3400 North Broad Street, Philadelphia, PA 19140, USA
| | | | | | | |
Collapse
|
45
|
Walters TJ, Ryan KL, Nelson DA, Blick DW, Mason PA. Effects of blood flow on skin heating induced by millimeter wave irradiation in humans. HEALTH PHYSICS 2004; 86:115-120. [PMID: 14744044 DOI: 10.1097/00004032-200402000-00001] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
We have previously reported species differences in the rate of skin heating in response to millimeter wavelength microwave exposure. We hypothesized that these differences were predominantly a function of species differences in the ability to increase skin blood flow during local heating. Mathematical modeling also suggested that, in humans, the rate of skin heating during prolonged millimeter wavelength exposure would be dependent on skin blood flow. In order to empirically test this hypothesis, we determined the role of baseline skin blood flow on the rate of cutaneous heating induced by 94-GHz microwave energy in humans (3 female, 3 male) using infrared thermography and laser Doppler imaging to measure skin temperature and relative skin blood flow, respectively. Millimeter wavelength exposure intensities used were high power (HP), 1 W x cm(-2) for 4 s and low power, 175 mW cm(-2) for 180 s. Skin blood flow was (a) normal, (b) eliminated using a blood pressure cuff to occlude forearm blood flow, or (c) elevated by heating the skin prior to irradiation. Results showed that for the HP exposures, these manipulations did not influence the rate of skin heating. For the low power exposures, occlusion of baseline skin blood flow had a small impact on the subsequent rate of heating. In contrast, a two-fold elevation in baseline skin blood flow had a profound impact on the subsequent rate of heating, resulting in a substantially lower rate of heating. Occlusion of an elevated skin blood flow reversed this lower rate of heating. The results of these studies demonstrate that relatively small changes in skin blood flow may produce substantial alterations in the rate of skin heating during prolonged 94-GHz exposure.
Collapse
|
46
|
Abstract
This white paper combines a tutorial on the fundamentals of thermoregulation with a review of the current literature concerned with physiological thermoregulatory responses of humans and laboratory animals in the presence of radio frequency (RF) and microwave fields. The ultimate goal of research involving whole body RF exposure of intact organisms is the prediction of effects of such exposure on human beings. Most of the published research on physiological thermoregulation has been conducted on laboratory animals, with a heavy emphasis on laboratory rodents. Because their physiological heat loss mechanisms are limited, these small animals are very poor models for human beings. Basic information about the thermoregulatory capabilities of animal models relative to human capability is essential for the appropriate evaluation and extrapolation of animal data to humans. In general, reliance on data collected on humans and nonhuman primates, however fragmentary, yields a more accurate understanding of how RF fields interact with humans. Such data are featured in this review, including data from both clinic and laboratory. Featured topics include thermal sensation, human RF overexposures, exposures attending magnetic resonance imaging (MRI), predictions based on simulation models, and laboratory studies of human volunteers. Supporting data from animal studies include the thermoregulatory profile, response thresholds, physiological responses of heat production and heat loss, intense or prolonged exposure, RF effects on early development, circadian variation, and additive drug-microwave interactions. The conclusion is inescapable that humans demonstrate far superior thermoregulatory ability over other tested organisms during RF exposure at, or even above current human exposure guidelines.
Collapse
Affiliation(s)
- Eleanor R Adair
- Air Force Senior Scientist Emeritus, Hamden, Connecticut, USA.
| | | |
Collapse
|
47
|
Alekseev SI, Ziskin MC. Local heating of human skin by millimeter waves: A kinetics study. Bioelectromagnetics 2003; 24:571-81. [PMID: 14603477 DOI: 10.1002/bem.10137] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Heating rates of human skin exposed locally to 42.25 GHz mm waves, coming from a waveguide (WG) opening or a YAV device designed for therapeutic application, were studied in vivo using infrared (IR) thermography. For both radiators, the power density distribution was described by a circularly symmetrical Gaussian type function on the exposed skin surface. Insertion of a small thermocouple (d = 0.1 mm) in the exposed area did not produce any significant artifact, either in the power density distribution or kinetics measurement, providing it was perpendicular to the E vector. The heating kinetics in the skin exposed with either the WG opening or the YAV device were well fitted to solutions of the 2-D bio-heat transfer equation for homogeneous tissue. Changes in irradiating beam size (1-8 mm) had no detectable effect on the initial (0.3-3.0 s) phase of the heating kinetics. However, the amplitude of the kinetics decreased substantially with decreasing the beam size. As the temperature rise in the time interval necessary for reliable measurement of the initial temperature rise rate was very small, an accurate experimental determination of specific absorption rate (SAR) becomes practically impossible at the low intensities normally used in our experiments. The correct SAR values may be found from fitting of the model to the heating kinetics. Bioelectromagnetics 24:571-581, 2003.
Collapse
Affiliation(s)
- S I Alekseev
- Institute of Cell Biophysics of Russian Academy of Sciences, Pushchino, Moscow Region, Russia
| | | |
Collapse
|
48
|
Foster KR, D'Andrea JA, Chalfin S, Hatcher DJ. Thermal modeling of millimeter wave damage to the primate cornea at 35 GHz and 94 GHz. HEALTH PHYSICS 2003; 84:764-769. [PMID: 12822586 DOI: 10.1097/00004032-200306000-00009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Recent data on damage to the primate cornea from exposure to millimeter wave radiation are interpreted in terms of a simple thermal model. The measured temperature increases during the exposures (duration 1-5 s, 35 or 94 GHz, 2-7 W cm(-2)) agree with the model within the variability of the data. The thresholds for damage to the cornea (staining of the corneal epithelium by fluorescein and corneal edema) correspond to temperature increases of about 20 degrees C at both irradiation frequencies. Within the limits of the one-dimensional model, thresholds for thermal damage to the cornea can be predicted for a range of exposure conditions.
Collapse
Affiliation(s)
- Kenneth R Foster
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | | | | | | |
Collapse
|
49
|
Nelson DA, Walters TJ, Ryan KL, Emerton KB, Hurt WD, Ziriax JM, Johnson LR, Mason PA. Inter-species extrapolation of skin heating resulting from millimeter wave irradiation: modeling and experimental results. HEALTH PHYSICS 2003; 84:608-615. [PMID: 12747480 DOI: 10.1097/00004032-200305000-00006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
This study reports measurements of the skin surface temperature elevations during localized irradiation (94 GHz) of three species: rat (irradiated on lower abdomen), rhesus monkey (posterior forelimb), and human (posterior forearm). Two exposure conditions were examined: prolonged, low power density microwaves (LPM) and short-term, high power density microwaves (HPM). Temperature histories were compared with calculations from a bio-heat transfer model. The mean peak surface temperature increase was approximately 7.0 degrees C for the short-term HPM exposures for all three species/locations, and 8.5 degrees C (monkey, human) to 10.5 degrees C (rat) for the longer-duration LPM exposures. The HPM temperature histories are in close agreement with a one-dimensional conduction heat transfer model with negligible blood flow. The LPM temperature histories were compared with calculations from the bio-heat model, evaluated for various (constant) blood flow rates. Results suggest a variable blood flow model, reflecting a dynamic thermoregulatory response, may be more suited to describing skin surface temperature response under long-duration MMW irradiation.
Collapse
Affiliation(s)
- D A Nelson
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931, USA.
| | | | | | | | | | | | | | | |
Collapse
|
50
|
Adair ER, Mylacraine KS, Cobb BL. Human exposure to 2450 MHz CW energy at levels outside the IEEE C95.1 standard does not increase core temperature. Bioelectromagnetics 2001; 22:429-39. [PMID: 11536284 DOI: 10.1002/bem.70] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Permission was received from the Brooks AFB Institutional Review Board and the AF Surgeon General's Office to exceed the peak power density (PD = 35 mW/cm(2)) we had previously studied during partial body exposure of human volunteers at 2450 MHz. Two additional peak PD were tested (50 and 70 mW/cm(2)). The higher of these PD (normalized peak local SAR = 15.4 W/kg) is well outside the IEEE C95.1 guidelines for partial body exposure, as is the estimated whole body SAR approximately 1.0 W/kg. Seven volunteers (four males, three females) were tested at each PD in three ambient temperatures (T(a) = 24, 28, and 31 degrees C) under our standard protocol (30 min baseline, 45 min RF exposure, 10 min baseline). The thermophysiological data (esophageal and six skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow) were combined with comparable data at PD = 0, 27, and 35 mW/cm(2) from our 1999 study to generate response functions across PD. No change in esophageal temperature or metabolic heat production was recorded at any PD in any T(a). At PD = 70 mW/cm(2), skin temperature on the upper back (irradiated directly) increased 4.0 degrees C in T(a) = 24 degrees C, 2.6 degrees C in T(a) = 28 degrees C, and 1.8 degrees C in T(a) = 31 degrees C. These differences were primarily due to the increase in local sweat rate, which was greatest in T(a) = 31 degrees C. Also at PD = 70 mW/cm(2), local skin blood flow on the back increased 65% over baseline levels in T(a) = 31 degrees C, but only 40% in T(a) = 24 degrees C. Although T(a) becomes an important variable when RF exposure exceeds the C95.1 partial body exposure limits, vigorous heat loss responses of blood flow and sweating maintain thermal homeostasis efficiently. It is also clear that strong sensations of heat and thermal discomfort will motivate a timely retreat from a strong RF field, long before these physiological responses are exhausted. Published 2001 Wiley-Liss, Inc.
Collapse
Affiliation(s)
- E R Adair
- US Air Force Research Laboratory, HEDR, Brooks AFB, Texas 78235-5324, USA.
| | | | | |
Collapse
|